Registration of SAPCCM4x agent failed

Hi!
I would like to install a SAPCCM4x agent on the satellite systems host (Unix).
If enter the data of CEN system, user and password the connection to CEN cannot be established and I get the following error:
ERROR: RFC error: 104 RFC_ERROR_SYSTEM_FAILURE
(see RFC trace file or SAP system log for more details)
In file dev_rfc I could find:
Connection to host <hostname>, service 3302 timed out
Can some one help me to solve the problem?
Thank you very much!
regards
Thom

Hi Thom,
sometimes you can ping from hostA to hostB , however you are unable to ping hostB to HostA.
In this case, you need to check if both CEN and Satellite systems can ping each other.
this can be done using the 'ping' command at the OS level.
Check the page :
http://en.wikipedia.org/wiki/Ping
Also, I asked if you are able to use your SAP Logon pad to login into CEN using the same userid/password that you are using in the RFC destination.
Regards,
Siddhesh

Similar Messages

  • Agents failing when sent as attachments (pdf or excel) in OBIEE 11g

    Hello,
    We have issue agents failing with following error when set up with attachment (pdf or excel only) either as Dashboard or Report. If the same agent is run as inline then the agent is working fine. OBIEE version is 11.1.1.6.0 unclustered.
    [nQSError: 77006] Oracle BI Presentation Server Error: A fatal error occurred while processing the request. The server responded with: A fatal error occurred while processing the request. The server responded with: java.io.IOException: The system cannot find the path specified.
    Error Codes: AGEGTYVF
    Location: saw.rpc.mis.read, saw.subsystem.portal.pdf, saw.delivers.rpc.getDeviceContent, saw.rpc.server.responder, saw.rpc.server, saw.rpc.server.handleConnection, saw.rpc.server.dispatch, saw.threadpool.socketrpcserver, saw.threads
    We tried logging in as user/Administrator and running the report from catalog without any error. Also strangely this is evident in only a specific environment. Not sure what is causing the issue.
    Please advise.
    Thanks

    What is the size of the attachments of reports you are trying to send thru Agents .? either PDF or EXCEL ?
    What does you JavaHost log .?
    I think this is a same Bug 14680611 : ERROR CODES: AGEGTYVF RUNNING AGENTS WITH LARGE REPORT AS EXCEL ATTACHMENT
    If your are not able to download even smaller attachments/reports then, I would raise an SR with Oracle.
    Let us know. Hope this Helps.!
    Thanks,
    SVS

  • Why call between WebClient agents fails?

    Hi,
    I have just recently installed the mySAP CRM 4.0 IC WebClient (CRM40 SP00).
    I have been testing the installation with CCS (Contact Center Simulator) and for a basic CCS supported tests (Inbound Phone call, Outbound Phone call, Chat) everything seems to be ok, but a call between WebClient agents fails due to an java error. The Phone Call between WebClients which should work according the CCS webpage.
    What should I do to get WebClient agents to call each others? Any configuration or customization tips? Note that I do not have CC integration in place, just the IC WebClients.
    Here is the test done in details and the error reported by WebClient:
    0) I restarted SAP CRM to be sure no pending sessions exists
    1) Open the CCS to see that no agents are logged in with WebClient
    2) Login as java_ic with WebClient
    3) CCS shows java_ic Workmode (=status) as 'Not Ready'
    4) Switch java_ic to ready by from the WebClient
    5) CCS shows java_ic Workmode (=status) as 'Ready'
    Then I do the same for agent 'sap*' with another MSIE browser window. At this point, the CCS shows Workmode for both agents as 'Ready' and I have two WebClient browsers opened. I also verify that both has Phone selected from the channel selector in the WebClient.
    6) With java_ic agent, I press the Dial Pad, enter the sap* agent phone
    number (Phone: +15550002; shown in the CCS for both agents logged in) and then I press the Dial button on Dial Pad to call to +15550002.
    6.1) After pressing the Dial button, the WebClient displays a pop-up in
    the middle of the screen with info: "Your request is being processed." After this there is an Info message under the buttons in the WebClient for java_ic saying: "No account information found".
    7) Java_ic WebClient shows that it's doing an outbound call and is 'Dialing' state.
    8) sap* WebClient window has blinking button with labels 'Accept' and 'Reject'. So, it clearly got an notification of the Inbound Phone call coming from java_ic. But there is also an error message under the buttons in the same WebClient webbrowser screen (not in the JavaConsole, not in separate alert message this time) for sap*:
    "Java error: type= APPLICATION ERROR, ID= GETIAD_FAILED, description=".
    9) With sap* WebClient I cannot answer or reject the call. Nothing happens. The browser Status Bar says: javascript:void(0) when I press the Accept button.
    10) At this situation, the CCS shows that the agents's sap* Workmode is
    switched from the previous 'Ready' state to 'Not Ready' automatically (while the sap* WebClient status is still in Ready). So, the sap* automatically, due to the error, changed the status to 'Not Ready'.
    11) java_ic remain on 'Dialing' status for all the time trying to get connected with sap*.
    I got informed that the call between WebClient COULD BE seen as a "call transfer" between clients by the CRM system. This might be something to do with the problem in calling between WebClients.
    Because the java_ic reports: "No account information found" when placing the Outbound Phone call, one could assume that account details should be passed along with the call transfer. Possibly sap* cannot receive the
    inbound phone call due to a missing account information thus reporting java error: "Java error: type= APPLICATION ERROR, ID= GETIAD_FAILED, description=".
    Best Regards,
    Jani

    [loaded]  com.genieo.completer.download.plist Adware! [Remove]
      [loaded]  com.genieo.completer.ltvbit.plist [Support]
      [running]  com.genieo.completer.update.plist Adware! [Remove]
      [not loaded]  com.macpaw.CleanMyMac.helperTool.plist [Support]
      [not loaded]  com.macpaw.CleanMyMac.trashSizeWatcher.plist [Support]
      [not loaded]  com.macpaw.CleanMyMac.volumeWatcher.plist [Support]
      [loaded]  com.macpaw.CleanMyMac2Helper.diskSpaceWatcher.plist [Support]
      [loaded]  com.macpaw.CleanMyMac2Helper.scheduledScan.plist [Support]
      [loaded]  com.macpaw.CleanMyMac2Helper.trashWatcher.plist [Support]
    Your machine is slow because you loaded a bunch of third party junk on it.

  • Calendaring agent failed with error code 0x8000ffff Event id 8206 and 8207

    Hi to all
    We have an Exchange 2007 SP3 with Update Rollup 11 and all the user use Outlook 2003 with SP3.
    Suddenly in our Exchange Server we have start to receive a lot of 8206 and 8207 EXCDO errors in the Application.
    Event Type: Error
    Event Source: EXCDO
    Event Category: General
    Event ID: 8206
    Date:  5/2/2015
    Time:  11:17:41 πμ
    User:  N/A
    Computer: EXCHANGESRV1
    Description:
    Calendaring agent failed with error code 0x8000ffff while saving appointment.
    For more information, see Help and Support Center at
    http://go.microsoft.com/fwlink/events.asp.
    Data:
    0000: 48 72 53 61 76 69 6e 67   HrSaving
    0008: 41 70 70 74 3a 3a 48 72   Appt::Hr
    0010: 43 68 65 63 6b 50 61 74   CheckPat
    0018: 74 65 72 6e 20 66 61 69   tern fai
    0020: 6c 65 64 2e 20 4d 61 69   led. Mai
    0028: 6c 62 6f 78 3a 56 61 73   lbox:x
    0030: 73 69 6c 69 73 2e 4b 6f   xxxx.xxx
    0038: 6e 74 6f 67 69 61 6e 6e   xxxxxxx
    0040: 69 73 40 45 55 52 4f 43   xx@xxxx
    0048: 48 41 52 54 49 4b 49 2e   xxxxxxx.
    0050: 47 52                     GR     
    Event Type: Error
    Event Source: EXCDO
    Event Category: General
    Event ID: 8207
    Date:  5/2/2015
    Time:  11:19:41 πμ
    User:  N/A
    Computer: EXCHANGESRV1
    Description:
    Calendaring agent failed with error code 0x8000ffff while deleting appointment.
    For more information, see Help and Support Center at
    http://go.microsoft.com/fwlink/events.asp.
    Data:
    0000: 48 72 44 65 6c 65 74 69   HrDeleti
    0008: 6e 67 41 70 70 74 3a 3a   ngAppt::
    0010: 5f 48 72 47 65 74 42 75   _HrGetBu
    0018: 73 79 49 6e 66 6f 20 66   syInfo f
    0020: 61 69 6c 65 64 2e 20 4d   ailed. M
    0028: 61 69 6c 62 6f 78 3a 56   ailbox:x
    0030: 61 73 73 69 6c 69 73 2e   xxxx.xxx
    0038: 4b 6f 6e 74 6f 67 69 61   xxxxxxxxx
    0040: 6e 6e 69 73 40 45 55 52   xxx@xxx
    0048: 4f 43 48 41 52 54 49 4b   xxxxxxxx
    0050: 49 2e 47 52               I.GR   
    All the errors come ONLY FROM 1 USER. 
    How can i fix this errors?
    If you require any further information do not
    hesitate to let me know
    Thanks and regards.

    You must ask in Exchange forum
    https://social.technet.microsoft.com/Forums/office/en-US/home?category=exchangeserver

  • Start of SMD agent fails!

    Hi!
    After the installation of SMD AGENT 7.00 SP09 we've got some problems starting the agent.
    The errorlog says: (/usr/sap/SMD/J98/SMDAgent/log/SMDSystem.0.log)
    Oct 11, 2006 2:11:26 PM [Thread[SMDAgent connection thread,5,main]] Error      Exception ID: 1160572286256
    Registering agent on server myhost.de:50004failed:
    com.sap.engine.services.rmi_p4.P4RuntimeException: Unexpected exception.Nested exception is:
            java.lang.reflect.InvocationTargetException
    java.lang.reflect.InvocationTargetException
    However, the manual setup of the agent succeeds:
    ./smdsetup.sh /usr/java14_64 myhost.de 50004 j2ee_admin PASSWORD
    SAP Solution Manager Diagnostic - SMD Agent Setup - Copyright (c) 2005 SAP AG
    SMD Agent Setup is in process ...
    - STEP 1: checking JDK location
    JDK location is consistent: /usr/java14_64/bin
    - STEP 2: checking JDK Version
    JDK Version is correct: 1.4.2
    - STEP 3: checking Connection to SMD Server
    SMD Server check completed successfully
    - STEP 4: generating Runtime Properties
    runtime.properties has been created.
    - STEP 5: generating Launcher
    smdagent.bat has been created.
    smdagent.sh has been created.
    - STEP 6: generating SecStore
    secstore.properties: has been created.
    secstore.properties: user has been set.
    secstore.properties generation completed successfully.
    - STEP 7: checking P4 Connection and SMD Agent Registration
    SMD Agent Registration succeeded
    SMD Agent Setup completed successfully
    During the start process of the agent, the agent appears in the agent administration tab in SMD/admin, but it disappears after the erroneous shutdown.
    What can we do?
    Thanks for all hints solving our problem!
    Greetz,
    André Richter

    Hi Rahul,
    please try SMD Agent 7.00 SP10! We had no problems with this version!
    Also make sure that the OSUser has enough privileges. We use the "sidadm" to start the agent.
    Regards
    André

  • SAPCCM4X agents are shutting down by itself

    Hello Gurus
    A few SAPCCM4X agents are shutting down by itself and this is happening
    for systems which have a version 4.6c and 4.5B in our landscape like PCX.. Analyzing the log of one of this agents the
    message below is informed:
    Mon May 9 04:41:10 2011
    CCMCTRL: ERROR: csm_show_file: no permission to
    read /usr/sap/PCX/SYS/profile/PCX_G34_zonepcx
    CCMCTRL: ERROR: csm_show_file: Please check sapccmsr.ini
    I tried to find the profile mentioned in the warning but with no
    succes. The cause of the shutdown of the agent is that because the
    correct profile is PCX_DVEBMGS34_zonepcx instead of PCX_G34_zonepcx but
    why it is looking for the wrong one when everything is configured with
    the profile PCX_DVEBMGS34_zonepcx . I also checked sapccmsr.ini but
    found nothing.
    I  can start the agent normally choosing the correct parameter
    (PCX_DVEBMGS34_zonepcx) but sometimes the agent shutdown by itself
    after 3-4 days with the error message above.
    Why the agent search for the wrong profile and where can I change it to
    the right profile ?
    Or is there any other way to resolve it.
    Thanks and Regards
    Ashwini

    Thank you Mani, I will make this test in only one appl server and monitor.
    I will let you know the resul of my tests.
    Regards

  • Installation of SAPCCM4X-Agent on Windows Cluster

    Hi!
    I woulld like to install SAPCCM4X-Agent on Windows Cluster.
    Does anyone know the procedure here (e.g. install the agent twice on both nodes, etc.)...
    Thank you very much!
    regards
    Thom

    Hello Thom,
    Here is a note that will help you out.
    SAP Note 536954 - OS data in a cluster environment for OS07
    As per the note
    The CCMS agent must be located on a shared disk, so that the cluster administrator software can start the service later.
    Regards,
    Siddhesh
    Edited by: Siddhesh Ghag on May 27, 2008 11:02 AM

  • The distribution agent failed to create temporary files in 'C:\Program Files\Microsoft SQL Server\110\COM' directory. System returned errorcode 5.

    One of my replication job failed with below error, which means job failed because of permission issue on the folder. To resolve that, I have granted the permission and it started working fine. Now the question is as my job was running fine since long time
    without any issue then how suddenly the permission of the folder got omitted automatically? I am sure that no one deleted the permission from the folder and as the server is part of SQL cluster no failover occurs.
    Error:-The distribution agent failed to create temporary files in 'C:\Program Files\Microsoft SQL Server\110\COM' directory. System returned errorcode 5.
    Rahul

    Hi Rahul,
    Error code 5 indicates that the error is "access is denied."  Please make sure that the COM folder is excluded from any antivirus scan that occurs on the system.
    If the issue still persists, I recommend you use
    Process Monitor to find out a bit more about the accounts and access requests involved. Then grant write permission to the exact COM folder for the account that is running the SQL Server Agent service. For more details, please review the following similar
    thread.
    http://www.sqlservercentral.com/Forums/Topic1364832-1550-1.aspx
    Thanks,
    Lydia Zhang
    If you have any feedback on our support, please click
    here.

  • Distribution agent failed to create temporary files in

    Hello,
    we are configured transnational replication in sql server 2005 location, all replication jobs are running fine,
    while we checking sql server errorlog showing below error :
    Distribution agent failed to create temporary files in  'C:\Program Files\Microsoft SQL Server\100\COM' directory. System returned errorcode 5.
    NOte: normally we are configured replication 2005 [90] , but while see the above error it shows [100] comparability level . 

    Hi,
    If the account that is running SQL Server Agent does not have write access to the COM folder, the Distribution Agent will fail
    when it is running as a job. If you run the Distribution Agent from a command line by using an account that does not have write access to the COM folder, the same failure will occur.
    To work around this
    issue, grant write permissions to the COM folder for the account that is running the SQL Server Agent service. If you run the Distribution Agent from a command line, grant write permissions to the COM folder for the account that you use to run the Distribution
    Agent.
    For more information, please go through the below URL:
    http://support.microsoft.com/kb/956032/en-us  

  • SAPCCM4X Agent Shutdown

    Hello
    A few SAPCCM4X agents are shutting down by itself. Analyzing the log of this agents the message below is informed:
    Mon Aug 23 12:15:16 2010
    CCMCTRL: ERROR: csm_show_file: no permission to read /usr/sap/PRD/SYS/profile/PR
    D_G08_sapprdi
    CCMCTRL: ERROR: csm_show_file: Please check sapccmsr.ini
    I tried to find the profile mentioned in the warning but with no succes. I know that the cause of the shutdown of the agent is that because the correct profile is PRD_D08_sapprdi instead of PRD_G08_sapprdi. I also checked sapccmsr.ini but found nothing.
    I can start the agent normally choosing the correct parameter (PRD_D08_sapprdi) but sometimes the agent shutdown by itself with the error message above.
    Why the agent search for the wrong profile and where can I change it to the right profile?
    Thanks in advance

    Thank you Mani, I will make this test in only one appl server and monitor.
    I will let you know the resul of my tests.
    Regards

  • Automatic windows agent fail over in SCOM 2012 / 2012 R2

    Hi All,
    I have a question with respect to SCOM 2012 / 2012 R2 windows agent fail over.
    For example i have only 400 windows agents and i have 2 MS in my environment. So 200 windows agents are managed by MS1 and the rest 200 are managed by the MS2.
    What i want to know is if either of the MS (MS1 or MS2) Shutdown / restart or any thing happens to them, Do the agents automatically fail over to the other MS ? As i have not configured ant thing for this as i don't know.
    So is there any configuration to be done for the above to happen after the deployment of both the management servers is done before discovering the agents or does it automatically understand take the rest 200 agents thinking that the other MS is down ?
    Gautam.75801

    Hi All,
    I have a question with respect to SCOM 2012 / 2012 R2 windows agent fail over.
    For example i have only 400 windows agents and i have 2 MS in my environment. So 200 windows agents are managed by MS1 and the rest 200 are managed by the MS2.
    What i want to know is if either of the MS (MS1 or MS2) Shutdown / restart or any thing happens to them, Do the agents automatically fail over to the other MS ? As i have not configured ant thing for this as i don't know.
    So is there any configuration to be done for the above to happen after the deployment of both the management servers is done before discovering the agents or does it automatically understand take the rest 200 agents thinking that the other MS is down ?
    Gautam.75801
    This happens automagically for Windows agents within a domain that are assigned to a Management Server.  For other scenarios, such as Gateways, the Gateways should be configured for failover between Management Servers, and the agents attached to those
    Gateways should be configured to failover between the Gateways.  Cross platform agents report to a resource pool, so that happens automagically as well.
    To confirm your scenario, simply run the Get-SCOMAgent cmdlet.
    To test you can do the following, assuming first agent in the array isn't a Management Server/Gateway :)
    $SCOMAgents = get-scomagent
    $SCOMAgents[0].PrimaryManagementServerName
    $SCOMAgents[0].GetFailoverManagementServers()
    Supporting article:
    http://blogs.technet.com/b/jimmyharper/archive/2010/07/23/powershell-commands-to-configure-gateway-server-agent-failover.aspx

  • Mirror agent & failed logout-- HELP!

    There are a lot of other discussions on this topic, and many people seem to be familiar with the mirror agent failing to quit and freezing up the logout process, but I have been researching these discussions and the only one that had any tips was so specifically for people who understand macs in depth that I couldn't figure out what they were talking about.
    I have been having this mirror agent & failed logout issue for a really long time and I don't know how to fix it.
    And I don't understand when people just say "oh go to the whatever utility and take the tilda out of the library address" blah blah blah... I have no idea. :o)
    I see in the other discussions that this may be related to .Mac (I do have a .Mac account) or iDisk (I do use idisk, and have already changed the syncing preferences off of automatic) or something about mobile accounts... i don't really know what that is.
    logout is not the only time my powerbook is freezing up lately, and it's getting worse. I can no longer use Word without everything freezing up.
    Please please help! Don't be afraid to sound patronizing. I literally know nothing about the inner machinations of computers. I have tried a few other things based on other support discussions, but the problem still persists.
    THANKS!!!

    I've been having serious beach balls and I think it;s related ti iTunes but I noticed this post by TaosMouse and though ]t I 'd give it a try / let us know if it works .
    taosmouse
    Posts: 14
    From: Santa Fe, NM
    Registered: Jun 30, 2007
    Re: Safari freezing. force quit reveals "Mirror agent not responding" What now?
    Posted: Aug 22, 2007 4:09 PM in response to: Bigdog44
    Helpful
    Reply Email
    Mirror Agent can turn into your worst nightmare if your connection is intermittent. It will lock up the entire computer until it finishes what it was trying to do.
    This was annoying before, but it has become astoundingly un Mac like since .mac expanded to 10 gigs. Now you can wait 5 minutes if you have a problem. I know this because my wireless link (fixed wireless) someimes gets flaky, and I basically have to do situps until I can use my mac again.
    So.... Here's what you do: Go to System preferences -> .mac ->iDisk and click STOP under iDisk Synching On. That should do it, but you will no longer have a local copy of your iDisk to work with.
    MacBook Pro 2GB c2Duo Mac OS X (10.4.10) iPhone 8GB

  • Accessing execution agent failed

    Hi!
    I'm using Oracle 10g XE on linux. When I want execute any scheduler jobs get everytime the following error message:
    ORA-27370: job slave failed to launch a job of type EXECUTABLE
    ORA-27300: OS system dependent operation:accessing execution agent failed with status: 2
    ORA-27301: OS failure message: No such file or directory
    ORA-27302: failure occurred at: sjsec 3
    The user privileges and owner of the extjob is set correctly.
    The script runs on other servers without errors (on LINUX and WINDOWS too, but on 10g Enterprise Ed.).
    This error seems to be the 'OracleJobScheduler service not runnig' in case of Windows, but here is no service. I could generate this problem by hand with renaming the extjob file in a goodworking system.
    Could anyone help me in this problem? Why can't the oracle process see the extjob file?
    Thanks for help
    nmsAkos

    Hi,
    What schema are you running the jobs in ?
    In the SYS schema, the Scheduler uses the extjobo executable to execute jobs but I think on XE this executable might be missing so jobs in the SYS schema would be expected to throw this error.
    You could fix this by simply doing something like
    cp extjob extjobo
    chmod 0755 extjobo
    Or you could grant create job (and possibly create external job) to a regular user and have the user create the external job. I believe that in XE by default extjob is not setuid so all jobs would run as the oracle user. This may have security implications.
    If this doesn't help could you say what schema you are running the jobs in and give the output of "ls -l extjob*" in the oracle bin directory.
    Hope this helps,
    Ravi.

  • Installation problems with SAPCCM4X Agent

    Hi!
    I would like to install a SAPCCM4x agent on windows and have two problems.
    By one of the systems when i execute the commando for the installation sapccm4x -R pf=...
    I get the following error message:
    ERROR: Cannot open Monitoring Segment 0 rtc = 245
    Last reported error: 249 CCMS monitoring segment has wrong EYE CATCH: CCMS monitoring segment belongs to a non-ABAP
    SAPCCM4X of release 7.00 is to be used only to monitor ABAP instances of kernel release 7.00 (NW04s) or 6.40.
    By the second system I can install the SAPCCM4X agent, but the agent is stopped after 3 seconds.
    I have looked into the log files I do not detect any problems.
    Can some one help to solve the problems ?
    Thank you very much!
    regards
    Thom

    Hi,
    I could install XE in my (physical) machine with FC4 without any particular issue (just had to add some swap space); I also had to remove reference to ORACLE* environment variables prior to install the rpm (the rpm install warned me about both of the issues)
    I just miss the menu icons that are correctly installed in suse: did you manage to have them?
    Regards,
    Andrea

  • Sqlserver agent fails to execute the job

    Hi Team,
    Usually i am getting error with sqlserver agent job schedule with different errors for ssis package execution but manual execution of job getting fine for execution.
    Regards,
    Sarath

    Executed as user: CITRITE\svcacct_sqlappsprod. Started:  4:01:12 AM  Finished: 4:32:51 AM  Elapsed:  1899.48 seconds.  The package execution failed.  The step failed.
     Description: Failed to decrypt protected XML node "ServerPassword" with error 0x8009000B "Key not valid for use in specified state.". You may not be authorized to access this information. This error occurs when there is a cryptographic
    error. Verify that the correct key is available
    after getting error when we run the job with just right click on job and select run job st step 1 and then it is fine running.
    Regards,
    Kumar
    That's something related to Protection Level of SSIS Packages.
    Please refer similar thread and check reply by Wendy Fu. Hope that helps.
    https://social.msdn.microsoft.com/Forums/sqlserver/en-US/8df90455-19ea-449e-b80d-5590deb4fecb/sql-server-agent-failed-to-decrypt-protected-xml-node?forum=sqlintegrationservices
    Cheers,
    Vaibhav Chaudhari
    [MCP],
    [MCTS], [MCSA-SQL2012]

Maybe you are looking for