Remote panel portals?

Hi all,
We are looking to provide a solution for the control and display of multiple instruments by 2 workstations on a network.
We need the ability for a user at one workstation to assume control of some of the instruments, whilst the other user controls a different set of instruments.  Both users will need to see the display from all instruments.
Remote Panels seem to allow control of the server vi to be switched between server and client, but the control switch functionality appears to be for the whole application.
Is there any way of creating a 'portal' that holds control panels for each instrument allowing the user to elect which device to control?
Best regards
Phill

Hi Phill,
The following document describes what you're trying to achieve. I believe the example uses the Internet Toolkit though:
http://zone.ni.com/devzone/cda/tut/p/id/4041
Would it be feasible to have the two different sets of controls on two different VI front panels? It may be more straight forward to implement it in this manner.
There are also some licensing considerations to bear in mind, see the following links:
http://digital.ni.com/public.nsf/allkb/18C057D7C5A8EA0486256CAE0069557C?OpenDocument
http://digital.ni.com/public.nsf/allkb/2E814A22B7660EA786256BD500652F2C?OpenDocument
Sarah
Applications Engineer | National Instruments | UK & Ireland

Similar Messages

  • Remote Panel and Internet Explorer

    Hello. I have a problem with a Remote Panel and Internet Explorer. I create a measurement system in LabVIEW. It�s composed of a main front panel and a few subVIs with independent front panels opened from main Front Panel when I press appropriate button. As a local system everything works ok but I try to create a web version of this system. I decide that I can use a Remote Panel. In Web Publishing Tool I was creating a web page for each of Front Panel. I try to have the same functionality as in local system, so when in Front Panel (opened in Internet Explorer window) I press appropriate button I want to open secondary Internet Explorer window with a subVI inside. And now I�m stuck because I can�t open this secondary window in a network w
    orkstation. Has anyone have an idea how can I do it?

    > Hello. I have a problem with a Remote Panel and Internet Explorer. I
    > create a measurement system in LabVIEW. It?s composed of a main front
    > panel and a few subVIs with independent front panels opened from main
    > Front Panel when I press appropriate button.
    I think you have two options. You can open most modal subVI panels
    directly on a remote machine. The popup panels won't be in a web page,
    but it will work with few changes.
    A second approach would be to change the app slightly. The buttons that
    launch the subVIs will turn into URL links. The links will open a web
    page with a different embedded panel.
    Greg McKaskle

  • Open url in a remote panel

    HI.
    I want to put a button that launch a webpage. I works fine locally, when I click OK button, a  new internet window browser is open with the URL.
    But if I take the control in other PC client (using Web Publishing Tool) and I click OK button a internte window browser is open in THE HOST. I want to open the new window in the Client.
    Thanks.
    I attach the VI (open_google.vi) and the HTML file created by WPT (test.txt)
    Raymundo Cassani
    Attachments:
    open_google.vi ‏11 KB
    test.txt ‏2 KB

    Hello,
    When you view or control a VI using Remote Panels that VI is executing on the host side. The VI will not be able to interact with the operating system on a remote panel client. This means that it will not be possible to use this approach to open a browser window on the client side.
    You could take another approach- at least the way I would do it is thusly:
    Instead of putting the button that launches the page in the VI you could put it in the html file that the remote panel is hosted in.
    Using javascript you could pop up a new browser window with the URL you need.
    If you need to control what URL is viewed from within the VI you could make the button point to a URL that will be handled by your VI that can redirect to the URL you need. This would be easy to do in 8.6 as you could simply export the VI as a web service. Pre-8.6 you would either have to use the G web server or build a minimal web server yourself (this would be easier than it sounds since the server would have to do nothing but redirect).
    I should add that this approach would require some knowledge of HTTP/HTML/JavaScript.
    Let me know how it goes.
    Nathan
    Message Edited by NathanK on 10-15-2008 11:07 AM

  • Remote Panel not working in Windows 7 Starter

    Hi all,
    We have an application that can be controlled via remote panel. This is working fine in Windows XP PC. But when I try to access the same by opening Internet Explorer in a PC running Windows 7 Starter OS, I only get the 'Downloading 0.00% of 0 bytes'. I have disabled the Windows Firewall and there is no antivirus software also. What could be the reason for this? How could I solve this?
    Thanks in advance,
    Priyadarsini
    Solved!
    Go to Solution.

    The system which had the problem was a netbook that came with Windows 7 Starter. We found out recently that there was some parental controls utility in the netbook that prevented the LabVIEW Remote Panel access. We were not aware of its presence & it had not shown any indication that it had blocked Remote Panel communication. We uninstalled this utility & the Remote Panel started working as intended. Thanks again for your help.

  • Invalid server IP address for Remote Panels under LV 8.0.1

    The other messages for troubleshooting the "invalid server IP address" were very helpful with getting my EXE to operate as a remote panel.  But there is still one issue that I cannot resolve that seems to be caused by the 8.0.1 upgrade.
    The remote panel work perfectly using IE6 on a computer that has the LV 8.0.1 FDS or PDS installed.  When I use a computer that has LV 7.1 or no LV at all, the invalid server IP address appears inside the border of where the VI should appear on the HTML page.  The connection to the remote computer is correct, the HTML file is delivered by the web server in LV, but the panel part of the page returns the error. 
    Does the part of the HTML that loads the Run Time Engine need to be updated for 8.0.1?  Will the LV 8.0 RTE work for a remote panel on an EXE compiled for LV 8.0.1?
    The code is:
    var obj = '<OBJECT ID="LabVIEWControl" CLASSID="CLSID:A40B0AD4-B50E-4E58-8A1D-8544233807AD" WIDTH=1216 HEIGHT=915 CODEBASE="ftp://ftp.ni.com/support/labview/runtime/windows/8.0';
    if (lng.indexOf("fr") != -1) { obj = obj + '/French'; }
    else if (lng.indexOf("de") != -1) { obj = obj + '/German'; }
    else if (lng.indexOf("ja") != -1) { obj = obj + '/Japanese'; }
    obj = obj + '/LVRunTimeEng.exe">';
    Michael Munroe, ABCDEF
    Certified LabVIEW Developer, MCP
    Find and fix bad VI Properties with Property Inspector

    Thanks for the suggestion, Tunde.  After further experimentation, it seems that 8.0.1 was not the problem.  I worked perfectly when I removed the <parameter server=...  > line that I added manually.
    Michael Munroe, ABCDEF
    Certified LabVIEW Developer, MCP
    Find and fix bad VI Properties with Property Inspector

  • Can multiple PCs access one remote panel at the same time?

    I've written a program in labview 7.1 to monitor/control a labview application running in the test cell through Remote Panel. I and my coworker can remotely monitor and/or control this labview application individually. But if my coworker has the remote panel displayed on his PC and I try to get the remote panel on my PC, I get a labview error (63) as below:
    "LabVIEW:  Serial port receive buffer overflow.
    LabVIEW:  The network connection was refused by the server."
    My question is: Can multiple PCs access one remote panel at the same time?
    Thanks in advance!
    Y

    Sorry I wasn't clear. The remote panel license is separate from the number of LabVIEW development licenses. Pricing information on remote panel licenses can be found here.

  • How can I disable messages generated by Remote Panel?

    I created an application (EXE) to server its panel to other network clients.
    I used the Tools > Web Publishing Tool to generate a HTML code to create two different web pages to access this application using Web server:
    - Embedded (for some users who need visualize the panel in real time).
    - Monitor (to display panel snapshots to users updated every 1 second).
    I don't need anyone controlling the remote panel, so I used this option:
    Tools > Options > Web Server: Browser Access and checked Allow Viewing (not controlling) for every client connected.
    Ok, both are working fine. But it a user try to Request control of VI on the Embedded page (right click in the remote panel), the application running in the server displays a message: Denied control request from XXX: Check permissions.
    The embedded page stills working fine, but in the Monitor page that message appears in a box (see attached picture below)..
    Is there a way to disable all messages in the remote panel? I realized that I need to access the computer where the application EXE is running to close the message.
    I'm thinking in two solutions:
    - Unable the right click menu in the embedded page to avoid clients request control of the remote panel.
    - Run a code in the application to erase messages generated.
    Has anyone an idea how to solve this?
    Thanks in advance,
    Klein
    Message Edited by Klein on 08-06-2008 12:54 PM
    Attachments:
    Remote Panel message.jpg ‏10 KB

    Hi Dpcamargo,
    I'm already using monitor with a delay of 1 second and this doesn't seems real time like remote panel visualization.
    But you sent me a good tip: use java code to cancel right clicks at all....
    I will try this solution. 
    Hey, we are both brazilians! So, thank you so much, Dpcamargo.

  • Blink while alarm on using shared variables with remote panel

    I am creating an application where I have front panel indicators data bound to shared variables.  I also set it up to have them blink when the alarm is on.  I am using the DSC module.
    This works great under the development environment.  But when I connect using the remote panel, I can no longer see the blinking indicator if there is an alarm.  I can see the blinking indicator on the machine that is running the program, but no on any of the remote panels (I have no problems connecting to the remote panel and controlling the program).
    I have the remote panel set as embedded, since I want the user to be able to change some settings over the network.
    I am sure I am missing something simple, any ideas??
    thanks
    Kenny

    I have been using IE6 and Firefox, and I have found that the blinking does show up, if you refresh the page.  And then if the alarm stops and the blinking stops, you will not notice it until you refresh again.
    Kenny

  • Remote Panels not working in embedded viewing mode

    Hello,
    I'm trying to develop a web version of my project using Labview remote panels. I configured the web server properties as it's described here: http://www.ni.com/white-paper/4791/en/
    Currently I'm trying to create the web page on the web publishing tool. However when I select the Embedded viewing mode option I get an "Requested VI is not loaded into memory on the server computer" error on the web page that is created. But if I select Snapshot or Monitor viewing mode option the page is loaded without problems.
    I'm using Labview 2013 and oppening the web page in google chrome. The VI from which I'm trying  to create a remote panel has some subVIs that show the front panel when called. Is there anything I'm forgetting to configure, or do I need to have any plugins instaled on my browser?
    Solved!
    Go to Solution.

    Mateus23 wrote:
    I'm now developing the web version in HTML 5, using web services to comunicate with my labview application.
    There you go, good solution. When doing this remember that you have access to the database on the server. A structure I have found effective is to use the server DB like a dropbox that I write to, and the web server reads from.
    Mike...
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

  • Remote panel doesn't work

    I am using 2011 SP1 version of LabVIEW, toolkits and add-ons. I am trying to make the following remote panel opening VI work.
    This used to work well on LabVIEW 8.5 but now I get an Error 7 from the last Invoke Node of the second loop. The top loop works fine. HPAC Main.vi is running as a startup VI on the RT target (PXI-8106). I can open its front panel using this VI. But the second loop can't open ST_viewer 1.vi. File names and paths are all correct. For building HPAC.rtexe, on the Source Files tab, HPAC Main.vi was chosen as a startup VI while ST_viewer 1.vi was put in the Always Included box. The VI server of the PXI is using TCP/IP port 3363. The PXI is directly connected to this host PC by an Ethernet cable.
    I also made a very simple project (attached file named ServerTest), deployed its rtext to the PXI and ran it as startup. After rebooting, I tried to open the remote front panel of main.vi and sub.vi on the PXI using access.vi. I get the following errors at the Invoke Nodes.
    For trying to open main.vi > Error 1352: Requested VI is not loaded into memory on the Server Computer
    Fro trying to open sub.vi > Error 7: File not found......
    As suggested in the article, Real-Time System Manager seems useful but I can't find it. Tools > Real-Time Module > and then I can't find the system manager. I only see Project Wizard, Configure Time-triggered Network and Execution Trace Toolkit. Does 2011 version have something else?
    Any help will be appreciated!
    Attachments:
    HPAC Executable.vi ‏33 KB
    ServerTest.zip ‏215 KB

    Thank you, JaymeW. I found the VI States tab in the Distributed System Manager. And yes, all the steps in that article were already done.
    If I set sub.vi as a startup VI on the PXI along with main.vi, then I can open it using the same method that opens main.vi. However, if I put sub.vi in Always Included box on Source Files tab and use the VI server to open it, I get errors.
    On the VI States monitor, I see main.vi running as a startup VI on top level when I turn on the PXI. Then, I run access.vi and open main.vi successfully. When I click the sub.vi open button, sub.vi appears on the monitor with Run Top Level status but I get error messages.
    At the first attempt to call the remote front panel of sub.vi, I get:
    LabVIEW: Resource not found.
    An error occurred loading VI 'lvfpp0.vi'.
    LabVIEW load error code 3: Could not load front panel.
    From the second call, I get:
    Error 1000 occured at Invoke Node in access.vi
    Possible reason(s):
    LabVIEW: The VI is not in a state compatible with this operation.
    Method Name: Run VI.
    Could you take a look at the attached simple project and suggest a solution? Thank you!
    Attachments:
    ServerTest2.zip ‏218 KB

  • Labview Remote Panel and Client Aspect Ratio

    Dear all professionals,
    I had create an application with remote panel (webserver) enabled. I found that there is relationship between aspect ratio of client device display and the remote panel screen size. Here i attached two images of remote panel in browser which both remote panel are opened using different aspect ratio of client device. 
    The left 1 is the device with 1.5 aspect ratio while the right 1 is the device with 1.78 aspect ratio. 
    As you can seen from the images, both remote panel are shown in different size. May i ask do i miss something in the remote panel configuration? 

    Hi Michel,
    Thank you for your reply. I also notice that the zoom % of browser is one of the issue that caused this behaviour. In the same aspect ratio with server computer( where the application running), changing zoom to 100% will help to fit remote panel that I already set when I developing the remote panel vi. But if for different aspect ratio, no matter how u change the zoom % , it won't fit the frame. I just wondering whether got another solution for this issue or not :-(

  • Remote Panel Over Internet

    Hi All,
    Our office PCs r connected internally through LAN. Each PC set to get Automatic IP address. One PC is connected with external Modem. We have a laptop with internal modem. I am dialing the modem and connect to the PC with modem. Now after connection is established I try to use Remote panel then gives error like "network error" and "Remote Panel server not delivered specified vi" though the require vi is in memeory. I had also tried out by specifing the IP address but the same error repeats.
    Please let me know how could I solve this problem.
    Thanks.
    Vishal

    I have never run across this before, but I will throw out some ideas to get it rolling. Is this a fire wall issue? I assume because you are dialing in that it is not part of the network. Are you able to ping the computer that is hosting the remote panel? Are the run-time and LabVIEW development versions the same?

  • Remote Panel and DSC interfering?

    Hi, I wonder if DSC or OPC is interfering to view my remote panel in a executable, since I installed them and now I cannot see my web page. I mean the instructions says close Labview to gain acces with the executable, does DSC or the shared variabel Server or something is interfering?
    What happened:
    I have a program which monitors temperature for rooms with fruit, We acquire the temps through modbus RTU, and We see that info through internet.
    First I did it with the modbus libraries, and It worked, We had the web page working through remote panels and the web publishing tool.
    But now I saw the DSC toolkit for Labview, and excited about that I migrated the whole functionality to the IO servers, and until the very end, when everything else works ok, the web page or remote server doesn't works, works with the VI but not with the EXE.
    The first time I followed this, and I did this time again with not succes
    http://digital.ni.com/public.nsf/allkb/7F95D43D3F50FCAC8625710E000068E1
    Currently state:
    My Web server is started and works in development, I made a webpage named TRY.html, and it works in Labview with the VI.
    I know that the plugin doesn't works on chrome, but just to let you see that the problem is not IEXPLORER, whetn the web page is static it works on chrome too.
    With IEXPLORER (right) it works in chrome (left)  it doesn't
    Working on IExplorer
    So I followed the steps from the instructions, added the web page to my project, added to the build, and built
    Then I modified my NIconfigserver file, and CLOSED labview entirely, the tutorial says so, I closed at least as much as I used to do before.
    My ni config
    # Web server configuration file.
    # Generated by LabVIEW 14.0
    # 13/06/2015 11:44:16 p. m.
    # Global Directives
    NI.AddLVRouteVars
    ErrorLog "$LVSERVER_ROOT/logs/error.log", level=2, anew
    TypesConfig "$LVSERVER_ROOT/mime.types"
    LimitWorkers 10
    LoadModulePath "$LVSERVER_ROOT/..;$LVSERVER_ROOT/modules;$LVSERVER_ROOT/LVModules"
    LoadModule LVAuth lvauthmodule
    LoadModule LVSnapshot lvsnapshotmodule
    LoadModule LVRFP lvrfpmodule
    Listen 8000
    # Directives that apply to the default server
    NI.ServerName LabVIEW
    DocumentRoot "C:/SMC/data"
    InactivityTimeout 60
    SetConnector netConnector
    AddHandler LVAuth
    AddHandler LVSnapshot snap
    AddHandler LVRFP
    AddHandler LVSnapshot
    AddHandler fileHandler ""
    AddOutputFilter chunkFilter
    DirectoryIndex index.html
    My ini
    [SMC]
    server.app.propertiesEnabled=True
    server.ole.enabled=True
    server.tcp.paranoid=True
    server.tcp.serviceName="My Computer/VI Server"
    server.vi.callsEnabled=True
    server.vi.propertiesEnabled=True
    WebServer.Enabled=True
    WebServer.TcpAccess="c+*"
    WebServer.ViAccess="+*"
    DebugServerEnabled=False
    DebugServerWaitOnLaunch=False
    saveFloaterLocations=True
    find.viListFlags=0
    LastErrorListSize=0,0,0,0
    paletteStyle="NamedIcons"
    And so, I open my EXE, then reload the webpages, and I can see that the web server is started, because it shows the html, but I cannot link to my EXE. It says that can't find my VI
    Requested VI is not loaded into memory on the server computer
    If I close the EXE the server stops
    Remote Panel connection refused by specific server, Make sure Labview Web server is enabled
    And that's my history
    It's always hard for me to get the web page working, but this time I've spent hours without success
    I did the test in my development pc and in the target PC and is the same, on these PC's the webpage was working before using DSC.
    So any help will be appreciated
    My best regards

    The DSC Runtime Engine will be sufficient for the deploying the project to a new computer. The Run Time Engine is equivalent to the DSC Module, but you can't do any programming with it. You will need to purchase a separate license for the Runtime license for each deployment computer also. 
    What is the DSC Run-Time System and When Should I Use It?
    http://digital.ni.com/public.nsf/allkb/E56DB8726DB68F288625770E00594351
    Thanks,
    Frank
    Application Engineer
    National Instruments

  • Remote Panel and DataSocket

    In LabVIEW6.1,there is "Remote Panel"feature.And in http://digital.ni.com/demo.nsf/websearch/3DF73584759FF60986256ABD005BB446?OpenDocument&node=1381_US, there is a demonstration named "Weather Station".In LAN,I can control the VI from another host.But how can I control a VI from a host of different LAN or by Internet.For example ,can I bulid a remote panel which you can control from your own computer?
    Thanks.

    LabVIEW ships with a web server that is used to host your own applications. In LabVIEW 6.1 you find the tools to help you embed your own VI in a web page. These tools are found under Tools >> Web Publishing Tool and Tools >> Options >> Web Server. Most corporate networks have a firewall that you will have to deal with. In order for everybody inside or outside the firewall to access your remote panel, you will have to open a port through the firewall. Also, anyone that wants to view a remote panel will have to have either the LabVIEW Run-Time engine or full developments system installed.

  • Remote panel and selective control access through Security with DSC

    Hi Everyone,
    I looked around to see what labview had to offer concerning security of remote panel and all the solutions I've found only propose full access to a remote panel, or none. The login page is not an option for me as everyone on the intranet can access the remote panel for monitoring but not everyone can have control to the buttons on it.
    With the DSC module, I can give securities to the different controls and it works great with the exe, if I log in or out, the controls appears or disapears. Unfortunately, with remote panels, those controls are always visibles. Furthermore, when I log in from a remote panel, all the other remote panels get logged in with the same username and priviledges. When I log out, same thing, it logs out all the other remote panels. So the last guy who logs in gives its priviledges to every one else who is monitoring the remote panel at that time. when he logs out, he logs everyone out. I used a reentrant vi hoping that this would solve the problem but it didnt.
    I would like to do what my colleague does with Advantech without any problem. He has only 1 .exe is running on the server and whoever connects to it through webserver, just needs to log in and he has all the priviledges of an guest, operator, admin, etc.. with access to controls and features accordingly. All this without interfering with the other people using the remote panels. This colleague has always been doubtful about the capabilities of labview to do SCADA systems and uptil now, I've been able to prove him wrong.. please help me continue
    There are workarounds, using remote desktop to the server instead of webserver but it definitely is not as practical for the client and it will need quite some work to to synchronise all the exes open from the differents sessions, through the use of shared variables, binding and securities.
    Thank you for your help.
    Solved!
    Go to Solution.

    Thank you very much for your reply Jordan.
    The NI security info is on the server (local domain with groups and users), and the running exes as well. The remote panel is not supposed to be accessed by internet, at least not yet, but just by the computers on the network and thinkline computers who are directly connected to the servers. the remote panel is accessed through the simple url: http://serverip/Application.html
    There is no problem with accessing the remote panel of the exes on the server from another computer on the network. But there are several security issues when logging in and out with the NI Security Programmatic Login and logout VIs through the remote panel..
    The 1st problem occurs when several people access the remote panel at the same time. In my setup, everyone is allowed to check what's happening on the front panel of the running exe, go through the tabs, check the graphs, the tables, etc.. , but only the administrators and the operators can send commands to the machines and the production line through this remote panel. Hence some buttons are accessible to all users, while others are only accessible depending  on the privileges of the person logged in.
    So like I said in the 1st post, I configured some buttons to be accessible only by the users of the admin group. When the exe runs, it's perfect, if I log in and out with an admin account, the buttons appears and disappear accordingly. But when I check the remote panel, those admin buttons are always visible, even if I am logged in as a guest or even logged out. Is it because the remote panel only needs minimum runtime engine and doesnt use the dsc runtime engine? if so, any work around?
    Furthermore, another big problem is that if I login as an admin in one remote panel, then login as an guest in another remote panel, and then logout back from the first remote panel, it says: "User Domain/Guest logged out". Hence, my second login logged out my first user. I can actually see the admin buttons appearing and disappearing on the exe when login as admin and guest from the different remote panels.
    So that's it, I would like my remote panel to behave like a normal scada system, with one exe running in the back (on the server) and with all the users accessing it through web server. Several users might/will access the remote panel at the same time and each of the users have a login/password that grant some of them the privileges to take some actions while giving the others only monitoring rights.
    I hope that I have been more clear in this 2nd post,
    Thank you again for your time.
    Best Regards,
    Tom.