Hi
My operating system is Xp
Developer version is 6I
database 10g
i am runing report through form with run_product
When i run one report its show in background engin Preview i don't want to close this report
and i run 2nd report then its show waiting in preview i want to run 2 or more reports at a time
Regards
Shahzaib ismail
Shahzaib,
In Oracle 6i, you can open only 1 report at a time. As far as i know, there is no option to show more than 1 report.
Regards,
Manu.
Similar Messages
-
When I open up iphoto and click on the events tab then double click on an event, it used to show minis of all the photos in that event. Now it shows only one photo at a time. How do I get it back? Can you help?
On the bottom bar of the window (on the left iPhoto 11, on the right in other versions) note the slider. Drag it left.
Regards
TD -
Report Background Engine Memory Increasing on Reports 6i
Hi... we recently upgraded our ERP system from Developer 2000 to 6i. Some of our functions require many reports to print at once (labels, invoices, pick tickets, etc).. What we've noticed is that when we do this, the report background engine increases in memory significantly and does not release the memory when finished.... and can cripple the work station.
We know we can issue the Oracle_shutdown parameter to close the RBE after each report, but are there any other options as we feel this may slow down our printing?
Thanks,
ScottIf you use "dynamic" ref cursor, your package specification must have "dynamic" ref cursor type for (dynamic) query
(from 9i we can use predefined SYS_REFCURSOR built-in data type) and "static" ref cursor type for Report Layout.
SELECT statement in "dynamic" ref cursor must have the same number and type of columns as "static" ref cursor type.
And, of course, your package must be stored (=database) package, because PL/SQL engine in Reports 6i is v.8.0
but "dynamic" ref cursor is a new feature of PL/SQL v.8.1.
See
re:re:re:Can we create report based on stored procedure
Regards,
Zlatko -
How do I make preview show only one page at a time in full screen
When I show a document using full screen (or slideshow) in Preview, it shows two pages at a time. I just want to show one at a time, but can't find anything that lets me specify this. There is no relevant Preference that I can see, and if I check single page in view and then choose full screen or slideshow in view, the first page is displayed fine, but then subsequent pages are displayed two up.
Hi, Eric,
Thanks. It looks like I didn't quite make my question clear enough, though.
I want to show a multi-page document one page at a time. If I open it and choose "full screen" in view, I get the first page showing just fine. But if I then use the arrow to go to the second page, Preview shows two pages (#2 and 3), and then continues to show the rest of the document two pages at a time when I advance using the arrow.
I want to show one page at a time, and be able to advance to the next page using the arrow.
Can I do this in Preview?
Thanks,
Russ -
How can I set Mail to show only one email at a time
Mail will group emails based on subject or sender and then I keep losing or missing emails because they get buried in a thread. Sometimes under another persons name!
I'm old and easily confused.
I just want one email per line. No grouping. Can't seem to figure out how.
Thanks!Hi Keefer-in-space!
You may need to try turning off the “Include related messages” setting in the preferences of your Mail program:
Lion Mail: View conversations
http://support.apple.com/kb/PH4825
Thanks for coming to the Apple Support Communities!
Cheers,
Braden -
I am able to access my Outlook email, calendar and contacts but some of the functionality I enjoyed on my old PC disappeared when I switched to an iMac.
I've upgraded to Firefox 8 but don't see any difference. Can you provide some guidance on changing the calendar view?
-
How to close the report background engine programatically in developer 6.0?
Friends,
We have developed our application using Oracle Developer 6.0 as front end and Oracle 9iR2 as a back end.
whenever the user is opening the application one session is creating after that if he runs any report the report background engine is started and that engine also creating one session. So, unnecessarily two sessions are opening for a single application.
So, how can we close the report background engine programatically after the report displays all the records?
Moreover, when the user close the application, the report background engine is still open. the user has to close the report background engine manually.
so how can we solve this issue?
Thanks
Sathyguyi got this while searching but its not working.....
Problem Description
Starting reports using a RUN_PRODUCT on Windows platforms starts a
Reports Background Engine (RBE). After leaving the forms application the
background engine is still running and must be terminated by the user.
Solution Description
This is intendet behaviour.
To close the Background Engine programmatically use the Reports Runtime parameter
ORACLE_SHUTDOWN. E.g.
Perform the following actions to stop the RBE when closing the Forms
application:
1) Create a dummy report which only does e.g. a SELECT * FROM DUAL
This report has a DESTYPE=FILE and a DESNAME to e.g. C:\TEMP\DUMMY.OUT
2) In the POST-FORMS trigger add the following code:
DECLARE
pl_id ParamList;
BEGIN
pl_id := Create_Parameter_List('dummy');
Add_Parameter(pl_id,'ORACLE_SHUTDOWN',TEXT_PARAMETER,'Yes');
Add_Parameter(pl_id,'PARAMFORM',TEXT_PARAMETER,'NO');
Run_product(REPORTS,'<<name dummy rapport>>',SYNCHRONOUS, RUNTIME,
FILESYSTEM,pl_id,NULL);
END;
Explanation
The Report Background Engine runs separately from the Forms application and
there is no direct relation between these processes. The Forms should signal
the RBE that is being closed.
When the Form is closed the POST-FORM triggers sends a dummy report to
the RBE. Since the ORACLE_SHUTDOWN=Yes parameter is used after running the
report the RBE is terminated.
A small side-effect of the solution is that a small file (5Kb) is created on
the file-system contaning the output of the dummy report. -
How avoid multi reports background engine (D2K6I + patch7 C/S)
after Developer tools migrate from D2K60 to D2k6i (with patch7), if call multi reports with ASYNCHRONOUS comm mode from forms, these will have multi reports background engine will startup, so need more session will connect to database, this is my need.
So I need have method to avoid startup multi reports background engine.
Not suggest me with SYNCHRONOUS comm mode or automatic close report background engine. the above two methods are difficulty to carry through for me.
Thanks & test regards!Before developer tools migration, When run a set of reports with ASYNCHRONOUS comm mode, only one reports background engine startup, and all report as queue requests in the reports background engine, this is my need. I don't want any change because developer tools migration
Please give me your idea, Thanks again. -
Close Reports Background Engine from reports
Hi,
I have a report that calls another report via SRW.run_report. Qhen the other report is called, Reports Background Engine opens and stays open, even after closing the called report.
How to programmatically close Reports Background Engine when closing the report. I have read on the forum some procedure to close it from "Forms", but not from report.
Thank you,
Jyou can not close the RBE from reports as it would require a report to be executed ... i guess you get the problem.
the only way to close the RBE is from forms.
thanks,
ph. -
What is "Report Background engine"and How to use it ?
Hi
I see this window shows up when I run Report each time, what dose it do?
"Report Background engine"The Reports Background Engine waits for any command lines to run reports. When it receives a command line,
it places that report in its queue. Typically, the Reports Background Engine receives command lines from a form or
graphic using the RUN_PRODUCT packaged procedure, or from a report using SRW.RUN_REPORT.
On Windows, you can use RWISV60 to submit a report to the Reports Background Engine for execution.
This is a more efficient method because it incurs less performance overhead than Reports Runtime. The command
line arguments for RWISV60 are the same those for RWRUN60. RWRBE60 is only used to run reports locally.
Thanks,
Siva -
Closing Reports Background Engine from VB
I have a Visual Basic 6 application that runs Reports 6 reports with the ActiveX control Rwsxa60.ocx. When you close the application, the Reports background engine is still open. Is there a way to close the engine through VB? Thanks in advance for any suggestions.
you can not close the RBE from reports as it would require a report to be executed ... i guess you get the problem.
the only way to close the RBE is from forms.
thanks,
ph. -
Report Background Engine Crashes
I have a problem with Report Background Engine. When I try running a report through forms, the Report Background Engine and the Forms Runtime hangs. And If I End Task the Forms Runtime, the forms runtime closes and the background engine shows the report properly. Now I am not able to run reports properly from the Forms.
In my coding I use RUN_PRODUCT for calling the report from the forms. The O/s is Windows 98.
Please provide me with a solution asap.Please apply latest 6i patchset and try. (Yours is very old. Latest is 6.0.8.0.24. So many bug fixes have gone in since your patchset)
-
Hello all,
I'm calling reports (v6.0.8.11) from forms (v6.0.8.11 ) using RUN_PRODUCT, but the background engine is taking an inordinate amount of time to start up, resulting in the first request to run a report coming back with an integration error. Once the background engine is up and running, then I can call reports without a problem.
To get round this I tried to start the background engine in a pre-form trigger on the form using WIN_API_SHELL.WINEXEC. This resulted in the form itself taking a long time to start up and then the report background engine still took a while before appearing giving me the same problem as earlier.
This is all on a P3 machine with 120m ram, running windows nt4. Does anyone have any bright ideas?We put the background engine into the startup folder in windows to solve this problem and most instance of another one
We get multiple background engines running when a report is started while the background engine is busy. -
How to hide report background engine window
hi
i m using reports6i and when i run a report thorugh forms,reports background engine window also invoke and i want to hide that winodw .any one know how to hide report background engine or is this possibl. if so plz let me how to apply this.
thnx in advanceHi,
call report using this code
begin
srw.run_report('report='||path_forms('R')||'SUB_LEDGER_BALANCE.rep
L=' || :control
|| ' cdate=' || to_char(:cdate));
EXCEPTION
when srw.run_report_failure then
srw.message(30, 'Error runing reports.');
raise srw.program_abort;
end;
if u use this code for calling report then report background engine window not open also u can open multipul report in same time
Rizwan Shafiq
www.rizwanshafiq.blogspot.com -
Reports Background Engine - How To Automatically Close?
I use Developer 6. When I run a Reports, using RUN_PRODUCT built-in from a menu, a REPORTS BACKGROUND ENGINE starts up automatically, and it opens a session with the server, and runs reports. Since it is in another session, I cannot use uncommitted records created in my Forms Runtime session in any of the reports.
Further, when I exit out of my application, this REPORTS BACKGROUND ENGINE stays put. The user is expected to physically go and close this window, and consequently the Oracle session at the server end.
I've been unsuccessful in figuring out how to close this window and exit from my Application.
Could any one enlighten me on how to close this REPORTS BACKGROUND ENGINE while exiting out of my application programatically please?
Regards,
Ramhello,
you can use the ORACLE_SHUTDOWN parameter to shutdown the RBE.
regards,
the oracle reports team --pw
Maybe you are looking for
-
I used to get "suggestions" until the other day. Now I get nothing. "Show Suggestions" is checked. I still have all the same search engines as before (Google, Yahoo, etc). Did the most recent update screw something up?
-
How to have a creative p5800 working in 5.1 mode and microphone at the same time
pls, can somebody advise, how can i use my creative p5800 in 5.1 mode and at the same time to have microphone working properly. for the moment i have installed my creative as stereo speakers and the mic is plugged into the sound card, which is not ve
-
Hi, I'm rather new to JSP / java in general. wondering if some of the experts could tell me how i could get the JVM I'm running on (JVM ID or name) from a JSP. Thanks in advance for your time and efforts.
-
IPhoto Cannot Be Launched!!!!
My iPhoto application was working fine until I enabled Photo Stream and tried to move some pics. to Photo Stream. Now when I try to launch iPhoto, I get a screen that the says "iPhoto application unexpectedly quit while trying to restore its windows.
-
Ipad slow after update help!!!
my iPad 2 is very slow since updating software even though I've got fibre broadban,can anyone had this problem and have a solution?cheers