Reset Activation Count

I got a new nook and when I try to activate it it says I have too many devises. When I troubleshoot it tells me to contact customer support to reset my activation count. When I call the # it hangs up on me. There is not e-mail address to customer care? At a loss as to what I can do at this point??? Looks like its in Adobe's hands but there's absolutely NO SUPPORT.

I agree that your explanation matches my experience when I was fortunate enough to chat with a knowledgeable technician during the last few years. However, here are some of the responses received recently from two technicians when I asked them to perform the reset. One of them agreed to perform the task but only after I strongly insisted that she do so.
"I have checked that you are facing issues with a free product of Adobe,let me inform you that we do not have any chat support for freewares so kindly visit forums.adobe.com to get help from our experts."
"So kindly visit forums.adobe.com to get help from our experts as there is no chat support available for this."
"I am sorry but ADE is a freeware as per Adobe policies".
"Please visit forums.adobe.com for the support of your product"
"We currently do not have phone and chat support available for Adobe Digital Editions and older products (How-To issues) ; however, we do have support documents available on our support portal".
"... we are not trained on digital editions and support is only available on forums.adobe.com"
I'm going to use your excellent response as a platform for my concerns regarding the inconsistent service provided by Adobe because the sample comments (listed above) made by the technicians are unhelpful and, frankly, unacceptable.
First of all ADE isn't "freewares". Each time a customer "purchases" an ebook or a library licenses an ebook for patron use, a fee is paid to Adobe. The content provider undoubtedly pays a large fee to obtain the Adobe Content Server utility (I've read this is around $15,000) and a maintenance fee yearly (some say this is $1100). These costs are passed to the end user (us), one way or another.
Secondly, a request by an end user to reset his/her authorizations doesn't constitute a "How-to" session. Forum members, virtually the only individuals to respond to forum questions (how often does an actual Adobe employee respond?), are the only people closely matching the tech's term for "expert". Obviously, none of us can reset each other's activations.
Thanks again for your clear explanation of not only the required procedure but also the, gently implied, warning that a member may have some difficulty obtaining needed assistance.

Similar Messages

  • "E_ACT_TOO_MANY_ACTIVATIONS or Adobe Activation Request Error 2004," contact us to have the activation count reset.

    "E_ACT_TOO_MANY_ACTIVATIONS or Adobe Activation Request Error 2004," to have the activation count reset.

    "E_ACT_TOO_MANY_ACTIVATIONS or Adobe Activation Request Error 2004," contact us to have the activation count reset. Can someone help please

  • How do I reset my activation count for cs4?

    I can't uninstall cs4 from my old computer.  I was told I could reset my activation count by contacting adobe is this true and can someone post  a link to contact them?

    Adobe ID, sign in, and account help
    Click the "Still Need Help?" links and you'll see a chance to connect with Web Chat.

  • Please reset my Adobe ID.  activation count  because of reinstalled and wiped phone without deauthor

    Please reset my Adobe ID.  activation count  because of reinstalled and wiped phone without deauthorize of  ID first.
    Did email support disappear?  Don't have time to waste chating with online support.

    how do you "Chat with an agent" to reset the activation count on the weekend or evening? 

  • Please reset my activation count for my adobe id

    Please reset my activation count for my adobe id [email protected]

    Adobe ID, sign in, and account help
    Click the "Still Need Help?" links and you'll see a chance to connect with Web Chat.

  • Reset Adobe ID activation count - who can i contact apart from live chat

    I need to reset my Adobe ID activation count. I have new hardware and when I try to activate ADE it says Too Many Activations.  The forums tell me to contact Live Chat but that is useless.  The last two operators have basically said that they have no expertise in this area and kicked me off.  Extremely frustrated right now.  Can anyone tell me who I should contact?

    Keep trying Chat.  There is a noticable lack of uniform training in the
    Chat operators.  They can reset the activation counter.  Also, you could
    open a case via the web, and if that's the way the Chat operators want you
    to do it, then they should be able to tell you how to open a case.
    ===============

  • Maximum activation  count (1 user) already reached on a new install

    I just installed a new Adobe Acrobat XI Standard package ordered from a third party. The first time I invoked the application, I received an error message that the maximum activation count (1 user) had been reached. I had 30 days to deactivate one user and activate this computer, What has to be done to overcome this problem?
    I have contacted the seller, but have yet to hear from him.

    contact adobe support and ask for an activation count reset, http://www.adobe.com/support/chat/ivrchat.html

  • Creating an array in a 'for' loop (resetting loop count)

    Hi,
    I am trying to integrate an acceleration signal coming from a CRIO analogue input to obtain the speed and then further integrate to get the displacement of a vibration system.
    I understand that in order to perform the integration, an array has to be fed in. My problem is that I could not buffer the signal in a buffer block as I couldn't find any buffer blocks. so I decided to create my an array of data using a 'for' loop. The 'for' loop nests inside a timed loop. The problem that I got stuck at is how to reset the 'for' loop in order to refill the buffer again at every iteration of the outer timed loop.
    I have attached the code if that helps. Note that I am using labview 2013.
    I would be gratefull if someone who had encountered a similar issue before can help me.
    Regards
    Ali
    Solved!
    Go to Solution.
    Attachments:
    acc_test.vi ‏42 KB

    Dear Altenbach,
    Many thanks for your reply.
    I need to make it clear that I have not had enough hands-on with labview, I have only used it for sometime in the past and now I have to in order to perform some active damping on a 50Hz running machine. I must stress the fact that what i find more intuitive to do in a different programming language (matlab or C) is not as straightforward in labview. so please bear with me if my code has basic mistakes .
    All what i am trying to do is obtain the speed and position from an acclerometer signal. unfortunately i dont have a position sensor so i have to measure acceleration then perform time integrations in order to obtain the speed and position respectively. I am using a compact Rio (later in FPGA mode) to take physical measurements of acceleration from the vibratory machine and where i managed to do this bit successfully. when it came to performing the integration, i had to create an array inside my timed loop since i couldn't find a buffer block. I implemented a 'for' loop inside a timed loop in order to build the array. however i got stuck at resetting the count of the 'for' loop in order to refill the array with new values at every new iteration of the outer timed loop. unfortunately, even a sensible answer has been suggested before, i dont seem to have been capable of doing it yet. I really spent all my day trying to figure a way out but not achieved it yet, nevertheless I have learnt many many things by playing around.
    I would be gratefull if you could comment on a possible way of doing what i am trying to do.
    Kind Regards
    Ali

  • Mail activity counter

    I've noticed that the "MAIL ACTIVITY" counter in the lower left corner is accumulating so that when I receive a new email it shows as receiving hundreds of emails and when I send an email similarly shows a high number that increases by one each time I send a new email.  Is there a way to reset the counter?
    Thanks

    I have the same problem as many other users. The displayed number of Incoming Messages shows anywhere between 1 and 100 or so but the actual received/downloaded messages can be between 0 and 10 or 20. Obviously I am not receiving a lot of messages on my iMac because I can get them on my iPad 2 or using my ISP webmail, messages show up there which never appear in my Mail.app on the iMac. But answering mail on my iPad is often inconvenient if I have to refer to previous data held on the iMac.
    The 'missing' messages are nowhere on Mail.app on the iMac. Not in Archive, not in Junk.
    I do not have IMAP or GMAIL accounts; just two standard POP acoounts with the one ISP. The ISP server has no problems because of the webmail and iPad mail as mentioned above.
    I have tried the latest 'cure' of taking accounts off line then back on but to no avail. Quit Mail and relaunch has no fix. 10.9.1 no fix.
    What to do? Wait for 10.9.2? I am so far reluctant to use third party mail apps as I always want to use Apple's inbuilt apps where possible. But this hassle is really tiring.
    Yes, I have sent feedback. And rebuilt Mailboxes.

  • How do i reset a counter in crio scan interface mode

    Hai,
         I am using cRIO 9104 with NI 9421(DI SINKING) module for my counter application in scan mode.
    I have a doubt that how do i reset my counter previous value when my system is in idle mode(i.e stable mode).I tried to use a timeout in property node, But i am not able to put a timeout in my code ,herewith I have attached the printscreen of my program.You can see the timeout option is in hide mode.Any other option is there to reset a counter.Kindly solve this problem and let me know the details.
    Thanks and Regards
    Jayanthi.K
    Attachments:
    Untitled.png ‏292 KB

    You need to get a refnum for the module.  The simplest way to do this is to drag the module in the project onto your block diagram.  It will drop a refnum constant for the module.  You will find all kinds of useful properties and methods on this refnum.  In this case the refnum is of a class named "SD Module" (where "SD" stands for "Specialty Digital") and it has a method on it for resetting counters.  See the attached screenshot of the block diagram.
    Ross Houston
    Senior Software Engineer
    RIO Software R&D
    Attachments:
    reset_counter.png ‏3 KB

  • How to reset a counter on external signal in LabView?

    Hallo there!
    I am using LabView v 8.5 and the NI USB-6211 to acquire signals, among them are the following:
    1) angular pulses from a rotary encoder
    2) a reference pulse for the rotary encoder witch will give a pulse on a specific position of the movement for every rotation
    3) value from a pressure sensor
    What I am trying to do is to create a pressure/volume diagram based on the pressure and volume inside a cylinder of an IC engine. To do this, I will need the angle of the engines crankshaft to calculate the pistons position in the cylinder. This way I can calculate the volume and put it in a xy graph to represent the volume (x-axis) and the pressure(y-axis).
    I am using clk0 to count the pulses from the angular encoder, and this works great. However I now need the reference pulse to somehow reset the count at the precise time it goes high in order to precisely know the angular position.
    How can I do this? And how precise will this be? And will I need any kind of synchronization with my pressure measurements? If so, how?
    The relevant part of the program I am working on resembles the Count Digital Events with reset.vi 33 KB as found in this thread. However, I don't know how to get the reference pulse to reset as the stop button is. How can I do this?
    In addition: the fast pulses of the angular encoder = 0-> ~10kHz. I seem to lose information if I use the basic level trigger detection.vi when I put this signal on an analog port.
    -J

    Hi Nick,
    If you have an X Series or 2nd Generation cDAQ chassis (basically any cDAQ chassis except for the 9172 or 916x sleeves) then you can implement:
    1,2,3,4,5,6,7,8,9,10,(reset),1,2,3,4,5,6,7,8,9,10,(reset),1,2...
    You would have to configure an Edge Count Task, set the initial value to 232 - 6 (such that the 6th count causes the counter to rollover, which generates a pulse on the counter output), and enable the count reset using your external signal:
    The count reset isn't currently available for other DAQ devices, but I believe it should be available on M Series (62xx) and TIO (660x, 6624) with a future driver release (some time in 2012).
    If you don't have an X Series (or gen II cDAQ), don't despair.  On other hardware, you can get close to the previous behavior with a counter output task, with the exception that the "reset" signal would only be detected after the 2nd tick after your pulse is output.  Also, the reset signal would have to occur at the beginning to arm the counter the first time.
    Or, you can get the 3rd behavior that you asked for by doing a continuous counter output task with the external signal as the source of the timebase ticks.  For example:
    1,2,3,4,5,6,7,8,9,1,2,3,4,5,6,7,8,9
    In toggle mode (default):
    6 ticks of initial delay, 2 ticks high, 7 ticks low, 2 ticks high, 7 ticks low, ... etc.
    In pulse mode:
    6 ticks of initial delay, 9 ticks high, 9 ticks low, 9 ticks high, 9 ticks low, ... etc.
    See here for an overview of the difference of the two modes.  Basically, pulse mode will emit a short pulse when TC is reached, and toggle mode will toggle the state of the counter.  You can't have less than 2 ticks as a high time, low time, or initial delay.
    Best Regards,
    John Passiak

  • T-code that  resets the counts in the storage bins

    hello,
    is there any T-code that  resets the counts in the storage bins.
    As we do our weekly counts it keeps a running total of how many bin are completed and allows us to track the warehouse's progress.
    Regards
    Goutham

    Of cource, very sorry to waste your time,
    I didn't even notice LOL
    But your question is a easy question so I am sure some one will respond with a good answer for you.
    our program name is RLREOLPQ
    not sure if the program is custon or just t-code
    gl
    Edit: may be a bad sign for you, maybe no standard t-code if we had to create a custum one
    Edited by: Arakish on Apr 1, 2010 10:32 PM

  • Using a hardware trigger to reset a counter

    Hi all...I am trying to using a quadrature encoder with A,B,Z outputs on an e-series card (pci-6052e). the problem is that the card does not support the z output since it only has 2 counters. So i am trying to find a way to get around this problem. I start off using ctr 1 (to the source pin of which i connect the A signal)..to count the events which will tell me how many angles the shaft has rotated through. The only other thing i need is to use the single pulse generated on the z line to reset the count each time it turns high. From reading posts it seems like i have to stop and restart the counter task to accomplish this. So the thing i dont know how to do is to convert that pulse on the z-line to a boolean value so i can run a case loop to stop and restart the task. I can use a daq-mx start trigger to look at the pulse but how do i convert that to a boolean value to run the case loop.
    Thanks in advance, Shyam.

    Hi Shyam,
    Depending on how fast the encoder will be rotating, you can do a few things. The simplist is to just read the Z index on a digital line as you have begun doing. Using a DAQmx Read, you can detect the state of the line and if the rotation is slow enough, you can use the boolean value. Again, this is not ideal. The newer M-Series boards have a counter input for the Z index in addition to being able to do change detection on digital lines which will make this task much easier. See if this works for your needs.
    Regards,
    Kent
    Applications Engineer 
    Digital Multimeter Home

  • NI-6602 - Encoder capture - resetting the counter to 0 through software - DAQmx

    Hello. A simple one. I'm using DAQmx to set up a task to set channel 0 on an NI-6602 as an angular encoder capture port. This is working fine and I can grab the position in degrees. The simple question is - How do I reset the counter to 0 through software. I can set up ZIndex to do it but how do I either reset the counter or set it with an arbritrary number? I can see a method to set it on startup but not during capture.
    Thanks.
    Will

    If working in LabVIEW, there are DAQmx property nodes that will allow you to set the "initial count" value, but ONLY while the task is stopped.
    If you can't count on a hardware z-index reset, another software technique I've used to avoid stopping the DAQmx task.  I make a wrapper function for all my encoder task access (see the Action Engine nugget for ideas...).   Inside this "Action Engine" wrapper, I use an uninitialized shift register to store my encoder's "virtual 0".  I add a simple function to the action engine for setting the "virtual 0" to be the current encoder position value.  Every time I read from the encoder, I first subtract off the virtual zero before returning the data.  As far ast the rest of the app is concerned, the encoder data it gets is just as if I were able to make a software call to DAQmx to set the raw count to zero.
    -Kevin P.

  • Generate a event every X seconds and reseting a counter

    Hi!
    I'm quite newby in programming in Labview and I need your help.
    I've programmed a counter that is send to a MySQL database every time I click a button. Now I want to change this click event to an event ocuring every X seconds and that every time this event occurs it resets the counter. How can I do that?
    I think it's not a difficult question for someone used to programming Labview but I can't find an accurate solution.
    Thanks a lot.
    Solved!
    Go to Solution.

    Something like this?
    Jean-Marc
    Jean-Marc
    LV2009 and LV2013
    Free PDF Report with iTextSharp
    Attachments:
    Automatic event LV86.vi ‏26 KB

Maybe you are looking for

  • BI : Error while creating generic datasource

    Hi Experts, While creating the generic DS , It is giving the me the below error: :Invalid extract structure template ZFI_AGED_TR_BAL of DataSource ZFI_AGED_BALANCE". Kindly advise. thanks & regards, M.S

  • Possible to recover data from a formatted partition? HELP!

    So I have the Windows 7 RC installed on a 150 gb hard drive. On a seperate drive, I had a storage partition sitting at the very end with all my documents, pictures, etc. It was 122 gb. I had 110 gb of unallocated space before it, so I decide to expan

  • Check for Payment Service Invoices - Canada

    When printing checks for Payment, using 2007A SP01 PL09, in the Canadian localisation, the stub lines print twice when printing a check for payment involving  service type AP invoices. It prints the lines correctly, then prints the invoice keys again

  • HT3204 The network connection timed out

    I ran a diagnostics test. It came back as: Connection attempt to Apple web site was unsuccessful. The network connection timed out. Basic connection to the store failed. The network connection timed out. Connection attempt to Gracenote server was suc

  • Local Procedures Calling Database Packages

    I have a procedure in a form which is calling a procedure in a database package. There are various parameters being sent to the package. The package is not executing. If I copy the same code of the package in to the form procedure, the same code is e