Retryable warning msg

i have 4 Sun StorageTek 2540 connected via fiber to Sun Fire X4600
the below warning appear many times since one month, 15 days ago all the zpool was degraded and i lose part of my data
could any one have solution for such error
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.warning] WARNING: /pci@7a,0/pci10de,5d@d/pci1077,143@0/fp@0,0/disk@w202400a0b85a33bc,9 (sd44):
Nov  4 01:58:41 wteniq1         Error for Command: write(10)               Error Level: Retryable
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.notice]   Requested Block: 348696594                 Error Block: 348696594
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.notice]   Vendor: SUN                                Serial Number:
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.notice]   Sense Key: Unit Attention
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.notice]   ASC: 0xc (write error), ASCQ: 0x0, FRU: 0x0
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.warning] WARNING: /pci@7a,0/pci10de,5d@d/pci1077,143@0/fp@0,0/disk@w202400a0b85a33bc,0 (sd53):
Nov  4 01:58:41 wteniq1         Error for Command: write(10)               Error Level: Retryable
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.notice]   Requested Block: 434132201                 Error Block: 434132201
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.notice]   Vendor: SUN                                Serial Number:
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.notice]   Sense Key: Unit Attention
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.notice]   ASC: 0xc (write error), ASCQ: 0x0, FRU: 0x0
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.warning] WARNING: /pci@7a,0/pci10de,5d@d/pci1077,143@0/fp@0,0/disk@w202400a0b85a33bc,7 (sd46):
Nov  4 01:58:41 wteniq1         Error for Command: write(10)               Error Level: Retryable
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.notice]   Requested Block: 382881665                 Error Block: 382881665
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.notice]   Vendor: SUN                                Serial Number:
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.notice]   Sense Key: Unit Attention
Nov  4 01:58:41 wteniq1 scsi: [ID 107833 kern.notice]   ASC: 0xc (write error), ASCQ: 0x0, FRU: 0x0
many thanks

thank  Pascal
i all ready check it before, where was no alarm  except
A controller cache backup battery has failed Tray.85.Battery.A
i read in one blog in the internet the below
The vendor unique ASC/ASCQ code 0xc0/0x00 within the Solaris host; it indicates that there is an internal timeout on the array because of too much load
do you think is it right
regards

Similar Messages

  • Sales order- Warning msg Static credit check

    Hi, SAP Guru,
    When I create a order & saving it ...a POP UP comes with warning msg the static credit limit exceeds..... Can any one please let me know the how I can remove the warning POP UP . As client do not want any pop up should come while saving the order.
    Please help.
    Thx & regards

    Hi,
    If you remove the entry from the field "Check credit" in "OVAK" T.Code,the credit check will not happen for this order type.Which we don't want.
    We need that the credit check should happen but the pop-up is to be removed.right?
    For this goto the T.Code "OVA8".
    Select your valid entry.Details.
    Remove the value as "blank" for the field "Reaction".Press F4 for more options.
    Beside this there is one more field "status/block" which is ticked means the order will be blocked for further transactions.And also status will be updated accordingly.
    These blocked order have to be released either by using the T.Code "VKM3/VKM1".
    Regards,
    Krishna.

  • WARNING MSG

    had my iphone with me out by the pool... it was on the side face down exposed to the sun... warning msg came up with a yellow triangle with an ! in the middle and the word temperature above it... seems to be working fine now... but was playing my ipod at the time and it just stopped playing...

    If the phone gets too hot, it will shut itself down. See p. 132 of the manual... http://manuals.info.apple.com/enUS/iPhone_UserGuide.pdf

  • Ho do we make msg. CK666 become warning msg when we do costing run?

    Dear Experts,
    The sys. activate transfer price for preserve use.
    When we do costing run for profit center valuation, the following error msg ocurred.
    CK666 Material 227BO0001/plant 1030: Transfer price could not be found.
    Diagnosis
    When switching profit center 0000008000->0000005000 (from the material component to the costing object), a transfer price could not be determined for transfer price variant 0 in respect of material 227BO0001 in plant 1030.
    System Response
    If you carry out costing for a profit center valuation, material 227BO0001 goes into the cost estimate without a value.
    If you create a cost estimate for group valuation, profit from material 227BO0001 is not transferred into the cost component split.
    Procedure
    Check the settings for transfer price variant 0.
    In OKEQ, the variant for TP is blank.
    Ho do we make msg. CK666 become warning msg when we do costing run? and let costing result can be release, or there's another way?
    Thanks in advance.

    There is alternative solution.
    Try using TCode SE91.
    Enter the class - CK and Enter the message number 666.
    Select that line message line.
    Go to Utilities, Click on "Where-Used-list" or press "CtrlShiftF3" from keyboard.
    Select programs and deselect all others.
    Identify your program and double click against that under short description.
    There you can change the letter from "E" to "W" as your requirement.
    NOTE: take assistance of ABAPer of this, Do enquire about the implication of the same in sandbox before doing anything on any other client.
    Thanks & Regards
    JP

  • Where warning msg & error  msg are maintained in SPRO

    Dear All,
                              pl give the menu path to know that Where warning msg & error  msg are maintained in SPRO.
    regards
    sap11

    Hi,
    In case of Purchasing, the path to maintain warning & error messages is:
    Material Management->Purchasing->Environment Data->Define Attributes of System Messages
    In case of Inventory Management,
    Material Management->Inventory Management and Physical Inventory->Define Attributes of System Messages
    In case of External Service Management,
    Material Management->External Services Management->Define Attributes of System Messages
    In case of Logistics Invoice verification,
    Material Management->Invoice Verification->Logistics Invoice Verification->Define Attributes of System Messages
    In case of Material Master,
    Logistics - General->Material Master->Basic Settings->Define Attributes of System Messages
    Then, for eash message no., Maintain whether the message is to be shown as warning or error or information message.
    Reward if useful.
    Thanks & Regards,
    Komal

  • Supress warning msg during RRI

    We have a query that jumps to R/3 tcode. when we try to jump, for some document no's the jump goes smooth .. for some other doc's, it throws a warning msg saying that the infosource is not linked to the source system. this happnes with some of the docs only. But the jump does go thru to R/3.
    I want to supress the warning msg during the jump. I tried in RSRT, but it doesnt help. the error code i get is RSBBS206. where do i have to exactly supress this warning?
    Any pointers or clues would be appreciated.
    thanks,
    Voodi

    Hi Vodi,
    In RSBBS, go to the sender query in change mode. There should be a tab in the middle column where you have to give your infosource name..
    For. eg If you want to jump from Cost centre report (BW) to Masterdata transaction in R/3, you ust assign this particular infosource in RSBBS settings..
    Hope it helps.

  • Warning msg "Signal is not contiguous"

    Hi,
    I used NI FGen to generate a sine wave to pump into a circuit (under test) and use NI Hi-speed Digitizer to capture the output of the circuit.
    The captured signal goes through a low pass filter.  This warning message appear at the filter when it is Run continuously.
    'Run Once' does not have problem.
    Has this got to do with synchronizing  the 2 modules in the PXI system or is it a matter of wrong sample rates.
    I have searched Help and it mentioned using TClk to synchronize the 2 modules. 
    How do you use TClk in Signal Express?
    How to solve this warning msg?
    Someone please help.....thanks.
    Regards,
    SeeMist

    Hello,
    I am glad to hear that you resolved the warning issue.  In regard to the other project, are you just interesting in generating the signal once?  What is the lay out of the steps in the project for both the FGEN and SCOPE?  Is the FGEN set to finite or continous generation mode?  How is the SCOPE step setup in the Execution Control tab? 
    SeeMist wrote:
    Currently (another project) I use the NI-FEN step to generate a signal from a .hws file (a 25khz burst signal).
    It works fine by itself and the "Scope Soft Front Panel" (SFP) is always good at capturing the generated signal.
    (The output of generator is externally connected to the input of the Scope).
    However, after I closed the SFP and inserted NI-Scope Acquire step in Signal Express, I was not always successful in capturing the signal generated.  Sometimes okay, sometimes not.
    The error occurred at the FGen step : "Finite Generation timeout"
    Do I have to initialise or there is a problem with my setting?  Trigger or synchronization problem?
    The setting of the FGen remains the same in both tests.
    The NI-Scope: Trigger = Edge ; Sample rate =100MS/s; Record Length =5000
    Samantha
    National Instruments
    Applications Engineer

  • Warning msg at the time of PR creation

    When I am creating the PR a Warning msg is being displayed as:-
    "Base unit of measure KG adopted from  material master record"
    Could anybody suggest me, why this msg is comming.
    and if I ignore it and go ahead with pressing enter, Is there any future impact by the same.

    Hi There
    When you create the PR, if you have not provide the unit of entry, System will read the master data and bring the base unit of measure,, and provide the warning message,, You can acknowledge that message and proceed further it is not an issue,,
    For more details ref the below link, it provides the details of diff units and usages,,
    http://help.sap.com/saphelp_46c/helpdata/en/a5/63310c43a211d189410000e829fbbd/content.htm
    Thanks
    Senthil

  • Warning msg. when trying to activate MP

    guys,
    I am trying to activate MP, and i am getting following Waring msg. ! what does it mean ? and how serious it it ?
    "The InfoProvider properties for ZCIA_M05 are not the same as the system default
    Message no. BRAIN376"
    thanks

    yes i did assign all the infoobject. i could activate it too, but before i could activate it, i got a warning msg.
    still, i ignore those and activate it.
    but i wasnt sure i serious it. Also i checked MP's properties and its all the same( like other MPs).
    But, i thought let me get some information from Experts about that worning !!!
    let me know if you have any idea about it.
    Also, When i was trying to Activate MP again, it was asking like " its already active, do u still want to active" and if i say yes, it
    gives me an error msg. " MP is not yet Locked"
    Do i need to Lock it ????? what is that ??
    thanks

  • Warning Msg - While checking Mulitproviders

    Hi Frds,
    When i am trying the check the mulitproviders, we are getting warning msg. Below is the warning msg which we getting.
    Error messages from point of view of OLAP processor:
    Message no. R7I127
    Now we have upgrade our patch level from 16 to 21.
    Kindly can anyone give me some solution to overcome these warning msg.
    Thanks
    Yuvi

    Has the MultiProvider ever been activated in the past? If you activate it, and it hasn't been activated previously, you'll get this message from time-to-time (another one of those "undocumented features"). After actiavting it, go back into the MultiProvider in edit mode and run a check on it. It shouldn't throw that warning anymore.

  • WARNING MSG . DURING J1IEX

    Dear All ,
                             user had created a Stock transfer P.o , in this P.o there in no tab of  invoice , now it's Goods rcvd  is done here all excise details are maintained , here exscise base value is visible for all line items . now user had to post J1IEX so as he clicks on simulate a warning msg comes that is -" PLEASE CHECK EXCISE BASE FOR ITEM IS ZERO ! ".
    Pl help what to do .
    sap11

    Thanks guys, I figured it out.
    Message was edited by:
            voodi

  • Warning Msg during RRI

    When I'm trying to jump from a source report to target query via RRI, i get a warning msg (thought the query runs). I want to supress the msg.
    I tried supressing the msg in source query, target query and both of them together. Still the msg is being displayed. Where do I need to supress the msg if its during RRI process?
    The variable and the hierarchies being used for cost center is the same in both the queries. Any thoughts?
    Error msg:
    Invalid filter on 0COSTCENTER: Filter changed
        Message no. BRAIN502
    Diagnosis
        You tried to filter on a characteristic with active presentation
        hierarchy by a node of another hierarchy.
        This can only be done by switching the hierarhcy or for example by using
        the report/report interface.
    System Response
        The filter is not evaluated for the characteristic, but removed instead.
    Procedure
    Procedure for System Administration

    Thanks guys, I figured it out.
    Message was edited by:
            voodi

  • Report to Report Interface warning msg

    Hi,
    I am getting "Incompatible for target selection for fiscal year" warning msg in SAP BEX.I am using same variable in my source and target system to select fiscal year.
    How to supress this warning message?
    thanks
    venkii

    If your report is working fine as per expectation in RRI, and your requirement is to supress the warning message, you can set the global setting of the workbook to supress any warning messages.
    Question:
    Do you have any customer exit on this variable?
    - Danny

  • In Windows 7 warning msg says another version of Adobe CC installer is running while updating LR 5 to 6

    In Windows 7 warning msg says another version of Adobe CC installer is running while trying to update LR 5 to LR 6.

    Hi There,
    Kindly restart the machine and try to initiate the installation again.
    Download Lightroom 6: Digital photography software | Download free Adobe Photoshop Lightroom CC trial
    Serialize Lightroom CC trial to activate as Lightroom 6:https://helpx.adobe.com/lightroom/kb/serialize-lightroom-cc-trial-to-activate-as-lightroom -6.html
    Thanks,
    Atul Saini

  • Transport datasource 0FI_AP_4 on R3 gets warning msg

    RSA6 on R3 and select the datasource 0FI_AP_4, click the truck picture icon which is "Transport datasource", get a warning msg:
    "Warnings have occurred (see log)", click the question mark for log, but still get the same short msg.  What could be the reason? 
    The reason why we are doing this is that we found a new field added to the structure and correspondingly the datasource fails to show up in the target system after transported.
    Thanks

    Hi,
    If your ES in DEV has more filed than ES of QA/PROD , then yiou need to release and import the transport request of that change to ES.
    Without tranporting the change to ES first ,you are trying to transport the request of DS(which internally depends upon the ES) ,so you are getting warning.
    With rgds,
    Anil Kumar Sharma .P

Maybe you are looking for

  • Taxline itmes at Business Area level

    HI Gurus, My client wants Tax line itmes at Busienss Area level. Please help me on validation and substitutions to post taxline itmes at business area level. Below is the Scenario: Input Tax Purchase A/c--------------Dr (Business Area) Input Tax A/c-

  • Problem with removing Search and Advanced Search functionalities in Portal

    Hi,       As per our client requirement, we have removed search and advanced search functionalities in Masthead and those are working fine. But when ever we restarted the portal server, these search options are reappearing in portal.           I am n

  • ADF Rich Client Table

    Hi every one I face problem when creating table :the first things I make data bind : 1- data table collection (List o vector) 2-Element Type (MyBean.java) (for to view property) automatically put all properties from bean to table col my problem is :a

  • [SLVD] `sudo mount` from Apache's (mod_php) context isn't system-wide.

    Title field appears to be limited in acceptable symbols, so, the proper title would be `sudo mount` from Apache's (mod_php) context is successful, but not applied to whole system. Apache is run as http:http, http is added to sudoers as http ALL=(ALL)

  • Why is my iPhone 5 using so much data?

    I have had my iPhone 5 for exactly one month. I have a shared plan with my daughter. We are on wifi all of the time except when she is in school. I have only used .039 gig. Her phone has used14.47 gig in 29 days. 10 of those in the last 3 days. She d