Reverse Sign in Crystal report

Hi,
I am working on CR 2008 and SAP BEx query.My report requirement is to change the sign of values.
Suppose if one value is negative then show in the report as positive.same for positive to Negative.
I know how to do in the SAP Bi report.
If any one know then plz let me know how can we do in the crystal report.

Create a formula field and add a simple formula there that multiplies your key figure with -1. Add then the formula filed in your report instead of the original key figure.
Regards,
Stratos

Similar Messages

  • How to reverse sign +/- in FI statement

    Hi Guru
         I create P&L report on t.code OB58 and I want to reverse sign on output report such as the Revenue is generally displayed in the general ledger as a negative number but I want display  the sales are displayed as a positive number ,I try use +/- sign change indicator but not effect . How I can do?
    thanks very much
    methinee.s

    Hello,
    Sales figures in FI will be shown in Negative values (except credit memos) and positive in SD.
    This is standard, this cannot be changed.
    +/- (Debit and Credit Check box) symbol in OB58 is having different meaning.
    If you select this box, the system will display the account under this financial statement item if it has a debit balance / credit balance.
    Regards,
    Ravi

  • Issues with Apache integration with Crystal Reports

    Hi,
    We are using Apache as a reverse proxy to Crystal reports.
    Couple of our users are having an issue with the Re-direction or executing the Crystal reports. The apache logs show,
    [Sun Mar 08 14:42:38 2009] [error] [client 10.13.34.3] proxy: error reading status line from remote server
    I am sure this is to do with the Active X settings on the IE.
    Has anyone seen this issue ?
    Thanks, Nag

    Hi,
    If you are using ESS/MSS 1.0 then its poss thru MSS reports launchpad.
    Here is the link for it :-
    http://help.sap.com/saphelp_erp2005vp/helpdata/en/29/d7844205625551e10000000a1550b0/frameset.htm
    or you can do it from by publishing report first in BW andthen thru appintegrator/crystal iview you can put it into your portal.
    Use following link to create your iView :-
    http://help.sap.com/saphelp_nw04/helpdata/en/36/d4a94076b63713e10000000a155106/frameset.htm
    Crystal Report User guide..
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/90db5db3-a6a7-2a10-bba1-a5ba583cb7a8
    Regards,
    Jigar Oza
    Edited by: jigar oza on Sep 16, 2008 12:36 PM

  • Reverse +/- sign in report painter

    Hi all,
    When I make report painter, I can only define reverse +/- sign for whole row or column. I can't define +/- for each cell in one column. It is really a problem. How can I do?
    Thanks a lot

    can anyone help me, please?

  • Report painter - Reverse signs

    Hi,
    I want to change a report using the report painter. There is one specific line that I want to reverse signs, i.e. if the value is actually 2,500, I want it to be 2,500-.
    I'm trying to select this specific line by clicking on it and then F9 (Select/deselect). Then, I click on F7 (Reverse signs) and I get the message «Signs are reversed for the selected area».
    But the result is not good. It changes ALL the signs of every possible line, and not only the signs that I selected using F9.
    Thanks,
    Julien

    Hi,
    Using f7 u can reverse balance of all not for individual.
    Means If a row bal is cr(-), then it will become Dr(+) and
    if it is Dr(+) it will become  Cr (-).
    In short sigen of any cell depends on row characteristic balance.
    If  u r not able to clarify your doubt please sendus detail query like wether u r using GR31 tcode or else.
    Regards,
    Pari

  • Can't view Crystal Reports from BW

    Hi,
    I'm installing SAP Integration Kit XI 3.1 SP3 with IIS.  I am able to publish reports from BW to BOE but not able view them from BW.  I followed the documentation to use report/report_view.aspx to define the viewer application in Content Administration Workbench.  But it is giving me a "The page cannot be found" error when I try to view Crystal Reports from BW.  I tried looking for the file report/report.aspx but cannot find it.  I was able to locate the file in SAP_CrystalReport_View/report_view.aspx.  I repointed the system to this path but it still giving me the same error. 
    Anybody here encountered this before?
    Thanks,
    Elijah

    Hi Ingo,
    - has the report being saved to BW and then published to BusinessObjects enterprise ?
        Yes, the report is being published from BW to BOE successfully.
    - did you import the ABAP Transports to the BW system ?
        I imported all the transports that came with the Integration Kit.  I'm not sure if the ABAP transport is one of them.
    - has the viewing service in transaction SICF been configured ?
        Yes, the top entry in the handler list is /CRYSTAL/CL_BW_HTTP_HANDLER.
    I did notice that the BW system is on a different subdomain than the web application server.  For example,
       BW system        -  bw01.us.mydomain.com
       BOE web server -   boweb.mydomain.com
    Would that affect the single sign on?

  • Writing and including our own customer data source to Crystal Report Design

    Hi,
    I need to create a Crystal Report based on a locally stored XML and schema. I can do this but the issue Iu2019m facing is that some tags used in the schema and the format is not supported by Crystal. So my plan is to write a database driver which will take our format and then convert it to the format Crystal supports and vise versa. To do this before writing the driver I need to know if itu2019s possible to include my custom database driver source in to the list that is shown in the Crystal Report Designer when selecting a data source to create a report.  Is there such an API available so that I can plugin my data source to Crystal Report Designer? Is this at least possible to do or is there another way?
    Hope you can help me.
    Thanks you in advance.
    Regards,
    Chanaka

    Hi Chanaka,
    Not directly. If you base your driver on OLD DB or ODBC then it will show up in those lists.
    If you are planning on selling a lot of packages then you may want to contact our OEM Sales team and sign up. You'll have more resources to do customized features like this. Not sure if we can but the option is there.
    Thank you
    Don

  • Crystal Reports print preview problem

    Hello
    The problem is that print preview of a report using crystal Report dotnet Print Preview is  making u201Cblank signsu201D inside words. The blank signs occurs near Swedish special signs like u201Cåu201D, u201Cäu201D and u201Cöu201D. Also near u201C.u201D (dot). Maybe there are more signs making this problem.
    The problem occurs for those who have .NetRuntime, or a full installation of Crystal Reports
    The problem started when we installed Crystal Reports 12. In earlier versions we had no problem with this.
    It feels like Crystal Report have some bug in the u201Ctext rendering engineu201D. This is obviously a problem when a customer previews a text before printing it. This preview should look like the printout. Even if the room between two letters not is  a space, there still is a room that is interpreted as a space by a human.
    However, if we zoom to larger % (200%) the preivew is matching the report.
    Regards
    Kamlesh

    Make sure you have SP 2:
    https://smpdl.sap-ag.de/~sapidp/012002523100009038092009E/cr2008win_sp2.exe
    with FP 2.5 on top:
    https://smpdl.sap-ag.de/~sapidp/012002523100002975192010E/cr2008fp25.exe
    If the issue persists, since it is in the CR designer, post to the CR design forum:
    SAP Crystal Reports
    You need to resolve this in the designer, before trying to resolve it in a .NET application.
    Ludek
    Follow us on Twitter http://twitter.com/SAPCRNetSup

  • How do I create a crystal report layout with a table and borders

    My crystal report is a signin sheet. The sign in sheet has an ID column, Name column, Institution column, Place to signin column, and Weekday columns with checkboxes in each column for the visitor to checkoff.
    How do I display the data that is being used int he crystal report in a table layout with borders around each cell? And is it possible to center vertical alignment of the data within eacvh cell like Excel?

    Blahahaha! Great answer Deb!
    Seriously though... There is no vertical alignment in CR. There have been several past threads related to this issue and all of them have various workarounds. None of them are very elegant.
    The best workaround I've found (especially if you are grid or borders) is to turn off the boarders for the field itself and drawl a rectangle around the field(s). Now you can place the field in the lower portion of the rectangle and adjust the rectangles height to place the field text in the center of the rectangle.
    This will give you more control over the height of your elements than using a carriage return before the text.
    Jason

  • Error: 'bobj' is undefined - crystal report for VS2013 - please help ASAP

    Currently we are trying to migrate from VS2008 to VS2013 and we installed Microsoft Visual Studio Ultimate 2013 on a windows 7 laptop. All our crystal report programs are migrated to VS2013. I downloaded Crystal report Support Pack 10 (v. 13.0.10.1385) executable version and installed it. Then opened our old project (from vs2008) in VS2013 and it went through the conversion process. Later I opened each .rpt file and saved in VS2013 so that the crystal report files will be saved in the new format.
    I am getting the Error: 'bobj' is undefined when I try to run the report. Am I using the correct service pack 10, or should I use service pack 9. I have read through all the posts related to this error in earlier version of VS. Is there any correct fixes for VS2013?
    This is urgent, I am stuck with this error. please help??? Thank you.
    JS

    Don,
    I followed Adil Siddiqui's Blog and it worked!!!!
    Add Following code to web.config file
    <configSections>
    <sectionGroup name=“businessObjects“>
    <sectionGroup name=“crystalReports“>
    <section name=“rptBuildProvider” type=“CrystalDecisions.Shared.RptBuildProviderHandler,
    CrystalDecisions.Shared, Version=13.0.2000.0, Culture=neutral,PublicKeyToken=692fbea5521e1304,  Custom=null“ />
           <section name=“crystalReportViewer” type=“System.Configuration.NameValueSectionHandler“ />
    </sectionGroup>
    </sectionGroup>
    </configSections>
    <businessObjects>
    <crystalReports>
    <rptBuildProvider>
    <add embedRptInResource=“true“ />
    </rptBuildProvider>
    <crystalReportViewer>
    <add key=“ResourceUri” value=“~/crystalreportviewers13“ />
    </crystalReportViewer>
    </crystalReports>
    </businessObjects>
    NOTE: “<add key=“ResourceUri” value=“/crystalreportviewers13“ />” worked without the ~ sign.
    Click the link below for the complete post:
    Visual Studio 2012 Crystal Report not working on Windows Server 2012/ 0x800a1391 &amp;#8211; JavaScript runtime error: &…
    Thank you Don for your help.
    JS

  • Crystal Report - problem with passing parameters from J2EE app

    i'm trying to pass a few parameters from my java application to a crystal report using the code below:
    ParameterField pfield1 = new ParameterField();
    ParameterField pfield2 = new ParameterField();
    Values vals1 = new Values();
    Values vals2 = new Values();
    ParameterFieldDiscreteValue pfieldDV1 = new ParameterFieldDiscreteValue();
    ParameterFieldDiscreteValue pfieldDV2 = new ParameterFieldDiscreteValue();
    pfieldDV1.setValue("1056");//dform.getSelectedPeriod());
    pfieldDV1.setDescription("termId");
    vals1.add(pfieldDV1);
    pfield1.setReportName("");
    pfield1.setName("@p_termId");
    pfield1.setCurrentValues(vals1);
    fields.add(pfield1);
    // check here for null condition otherwise will throw nullpointerexception
    pfieldDV2.setValue("elect");
    pfieldDV2.setDescription("allocType");
    vals2.add(pfieldDV2);
    pfield2.setReportName("");
    pfield2.setName("@p_allocType");
    pfield2.setCurrentValues(vals2);
    fields.add(pfield2);
    this report calls a stored procedure (sql server). the report displays the data but the same is not the case when i call ity from my java application. with a single parameter it works fine (even though i get a "Some parameters are missing values" ERROR on the console. But when i pass, say 2 parameters, it give me the above error first and then "JDBC Error: Parameter 2 not set or registered for output"
    Can anyone bail me out of this one?
    thanks,
    ptalkad

    I don't know about naming conventions, but could the @ signs in the variable names cause a problem?
    How have you set up the mapping in Crystal?
    Is this parameter 2 an "out" parameter returning a value?
    What version of Java are you using?
    Version of Crystal?
    What JDBC driver?

  • How to do the reverse po in this report

    Hi,   
          i have a one problem in this report . i don,t know how to display the
    reverse po in this report. reverse po should have a po history cat. 'N' (field is bewtp)
    i connect type 'Q' and the type 'E' but not been able to connect the 'N'. when i connect it will give me the wrong amount and some field should not been displayed. i will provide u the following code.
           please help me.
    Thanks
      dinesh
    *& Report  Z_MM_PURCHASE_REGISTER
    REPORT  Z_MM_PURCHASE_REGISTER.
      Short Description: Purchase Register
    TABLES                                                              *
    TABLES : ekko, taxcom, ekpo, ekbe,ekkn,konv,komv,t007s, j_1imovend, bseg .
    TYPE-POOLS: slis.
    TYPES: Begin with TY_                                               *
    TYPES : BEGIN OF  ty_ekko,
              BSART LIKE EKKO-BSART,
              KNTTP LIKE EKPO-KNTTP,
              ebeln LIKE ekko-ebeln,
              knumv LIKE ekko-knumv,
              lifnr LIKE ekko-lifnr,
              waers LIKE ekko-waers,
              kalsm LIKE ekko-kalsm,
              lands LIKE ekko-lands,
              ekorg LIKE ekko-ekorg,
              wkurs LIKE ekko-wkurs,
              bedat LIKE ekko-bedat,
              ebelp LIKE ekpo-ebelp,   "po line item
              mwskz LIKE ekpo-mwskz,   "tax code
              bukrs LIKE ekpo-bukrs,
              matkl LIKE ekpo-matkl,
              mtart LIKE ekpo-mtart,
             netpr LIKE ekpo-netpr,   "Net price in purchasing document
             meins LIKE ekpo-meins,   "unit
              menge LIKE ekpo-menge,   "quantity
              txz01 LIKE ekpo-txz01,   "material description
              txjcd LIKE ekpo-txjcd,   "tax jurisdiction code
              matnr LIKE ekpo-matnr,
              llief LIKE ekko-llief,
              meins LIKE ekpo-meins,
              bprme LIKE ekpo-bprme,
              netpr LIKE ekpo-netpr,
              peinh LIKE ekpo-peinh,
             lifnr like lfa1-lifnr,
              name1 like lfa1-lifnr,
              pstlz like lfa1-pstlz,
              stras like lfa1-stras,
              text1 like t007s-text1,
    END OF ty_ekko.
    TYPES : BEGIN OF ty_ekbe,
              ebeln LIKE ekbe-ebeln,    "po number
              ebelp LIKE ekbe-ebelp,    "po line item
              buzei LIKE ekbe-buzei,
              belnr LIKE ekbe-belnr,    "Number of material document
              budat LIKE ekbe-budat,    "Posting date in the document
              xblnr LIKE ekbe-xblnr,    "Reference document number
              werks LIKE ekbe-werks,    "plant
              matnr LIKE ekbe-matnr,    "material
              menge LIKE ekbe-menge,    "quantity
              peinh LIKE ekpo-peinh,
              dmbtr LIKE ekbe-dmbtr,    "Amount in local currency
              kalsm LIKE ekko-kalsm,    "Procedure (pricing)
              waers LIKE ekbe-waers,    "currency
              wrbtr LIKE ekbe-wrbtr,    "Amount in document currency
              bwtar LIKE ekbe-bwtar,    "Valuation type
              shkzg LIKE ekbe-shkzg,
              maktx LIKE makt-maktx,
              mwskz LIKE ekbe-mwskz,
              bldat LIKE ekbe-bldat,
              srvpos LIKE ekbe-srvpos,
              packno LIKE ekbe-packno,
              introw LIKE ekbe-introw,
              lfbnr  LIKE ekbe-lfbnr,
              bwart TYPE ekbe-bwart,
              budat1 TYPE ekbe-budat,
              belnr1 TYPE ekbe-belnr,
           END OF ty_ekbe.
    TYPES : BEGIN OF ty_display,
              BSART LIKE EKKO-BSART,
              KNTTP LIKE EKPO-KNTTP,
              lifnr(10) TYPE C,              " LIKE ekko-lifnr,
              ebeln LIKE ekko-ebeln,
              bedat LIKE ekko-bedat,
              budat LIKE ekbe-budat,
              matnr LIKE ekbe-matnr,
              maktx LIKE makt-maktx,
              belnr LIKE ekbe-belnr,
              bldat LIKE ekbe-bldat,
              menge LIKE ekpo-menge,
              peinh LIKE ekpo-peinh,
              dmbtr LIKE ekbe-dmbtr,
              shkzg LIKE ekbe-shkzg,
              custduty LIKE konv-kwert,
              bed LIKE konv-kwert,
              cvd LIKE konv-kwert,
              sertax LIKE konv-kwert,
              sereducess LIKE konv-kwert,
              surcharge LIKE konv-kwert,
              educess LIKE konv-kwert,
              insure LIKE konv-kwert,
              freight LIKE konv-kwert,
              octroi LIKE konv-kwert,
              kursf LIKE rbkp-kursf,
              grossamt LIKE konv-kwert,
              vat4 LIKE konv-kwert,
              vat8 LIKE konv-kwert,
              vat125 LIKE konv-kwert,
              INC LIKE KONV-KWERT,     "
              PF LIKE KONV-KWERT,
              CF LIKE KONV-KWERT,
              INS LIKE KONV-KWERT,
              cst LIKE konv-kwert,
              subdeb LIKE ekbe-dmbtr,
              netamt LIKE ekbe-dmbtr,
              cenvatcreditbed LIKE konv-kwert,
              cenvatcreditecc LIKE konv-kwert,
              vatcredit LIKE konv-kwert,
              bgcharges LIKE konv-kwert,
              srvpos LIKE ekbe-srvpos,
              ktext1 LIKE esll-ktext1,
              sertaxcredit LIKE konv-kwert,
              sereducesscredit LIKE konv-kwert,
              totaltaxbenefit LIKE konv-kwert,
              inventoryvalue LIKE konv-kwert,
              bwart TYPE ekbe-bwart,
              belnr1 TYPE ekbe-belnr,
              budat1 TYPE ekbe-budat,
              lfbnr TYPE ekbe-lfbnr,
              bprme LIKE ekpo-bprme,
              meins LIKE ekpo-meins,
              name1 like lfa1-name1,
              pstlz like lfa1-pstlz,
              stras like lfa1-stras,
              mwskz like ekpo-mwskz,
              text1 like t007s-text1,
              kalsm like t007s-kalsm,
              j_1icstno like j_1imovend-j_1icstno,
              hkont(10) TYPE C,       " like bseg-hkont,
              saknr like ska1-saknr,
              sakan like ska1-sakan,
              ktoks like ska1-ktoks,
              mcod1 like ska1-mcod1,
              WAERS LIKE EKKO-WAERS,
              bukrs like ekpo-bukrs,
              total LIKE ekbe-dmbtr,
            END OF ty_display.
    TYPES : BEGIN OF ty_services,
               ebeln LIKE ekpo-ebeln,
               ebelp LIKE ekpo-ebelp,
               lfbnr LIKE ekbe-lfbnr,
               packno LIKE esll-packno,
               sub_packno LIKE esll-sub_packno,
               srvpos LIKE esll-srvpos,
               ktext1 LIKE esll-ktext1,
               netwr LIKE esll-netwr,
               act_wert  LIKE esll-act_wert,
               menge LIKE esll-menge,
               bldat LIKE ekbe-bldat,
            END OF ty_services.
    TYPES :  BEGIN OF ty_konv,
               ebeln LIKE ekpo-ebeln,
               ebelp LIKE ekpo-ebelp,
               knumv LIKE konv-knumv,
               kposn LIKE konv-kposn,
               kschl LIKE konv-kschl,
               kwert LIKE konv-kwert,
               kbetr LIKE konv-kbetr,
             END OF ty_konv.
    TYPES : BEGIN OF ty_lfbnr,
              belnr TYPE ekbe-belnr,
              lfbnr TYPE ekbe-lfbnr,
            END OF ty_lfbnr.
    TYPES : BEGIN OF ty_miro,
             belnr1 TYPE ekbe-belnr,
             belnr TYPE ekbe-belnr,
             budat TYPE ekbe-budat,
    END OF ty_miro.
    types: begin of ty_lfa1,
           lifnr like lfa1-lifnr,
           name1 like lfa1-lifnr,
           pstlz like lfa1-pstlz,
           stras like lfa1-stras,
           end of ty_lfa1.
    types: begin of ty_t007s,
           mwskz like t007s-mwskz,
           text1 like t007s-text1,
           spras like t007s-spras,
           kalsm like t007s-kalsm,
           end of ty_t007s.
    types: begin of ty_j_1imovend,
           lifnr like j_1imovend-lifnr,
           j_1icstno like j_1imovend-j_1icstno,
           end of ty_j_1imovend.
    types: begin of ty_bseg,
           lifnr like bseg-lifnr,
           dmbtr like bseg-dmbtr,
           shkzg like bseg-shkzg,
           hkont like bseg-hkont,
           BELNR LIKE BSEG-BELNR,
           end of ty_bseg.
    types: begin of ty_ska1,
           saknr like ska1-saknr,
           sakan like ska1-sakan,
           ktoks like ska1-ktoks,
           mcod1 like ska1-mcod1,
           end of ty_ska1.
    DATA : it_lfbnr TYPE STANDARD TABLE OF ty_lfbnr,
           wa_lfbnr TYPE ty_lfbnr,
           it_lfa1 type standard table of ty_lfa1,
           wa_lfa1 TYPE ty_lfa1,
           it_t007s type standard table of ty_t007s,
           wa_t007s TYPE ty_t007s,
           it_j_1imovend type standard table of ty_j_1imovend,
           wa_j_1imovend TYPE ty_j_1imovend,
           it_bseg type standard table of ty_bseg,
           wa_bseg TYPE ty_bseg,
          it_ska1 type standard table of ty_ska1,
           wa_ska1 TYPE ty_ska1,
           it_miro TYPE STANDARD TABLE OF ty_miro,
           wa_miro TYPE ty_miro,
           w_belnr TYPE ekbe-belnr,
           w_lfbnr TYPE ekbe-lfbnr,
           w_belnr1 TYPE ekbe-belnr,
           w_budat TYPE ekbe-budat.
    CONSTANTS: Begin with C_                                            *
    DATA: Begin with W_                                                 *
    DATA :  w_flag TYPE c.
    INTERNAL TABLES: Begin with IT_                                     *
    DATA : it_ekko TYPE STANDARD TABLE OF ty_ekko WITH NON-UNIQUE KEY ebeln
                                                                ebelp,
          it_ekpo type standard table of ty_ekpo,
           it_ekbe TYPE STANDARD TABLE OF ty_ekbe,
           it_ekbe1 TYPE STANDARD TABLE OF ty_ekbe WITH NON-UNIQUE KEY ebeln
                                                                ebelp,
           it_display TYPE STANDARD TABLE OF ty_display,
           it_subdebit TYPE STANDARD TABLE OF ty_ekbe,
           it_services TYPE STANDARD TABLE OF ty_services,
           it_packno TYPE STANDARD TABLE OF ty_services,
           it_konv TYPE STANDARD TABLE OF ty_konv.
    DATA :  it_fieldcat TYPE slis_t_fieldcat_alv,
            it_layout TYPE slis_layout_alv,
            it_komv TYPE STANDARD TABLE OF komv WITH NON-UNIQUE KEY knumv
            kschl.
    WORKAREAS: Begin with WA_                                           *
    DATA : wa_ekbe TYPE ty_ekbe,
           wa_ekbe1 TYPE ty_ekbe,
           wa_ekko TYPE ty_ekko,
           wa_komv TYPE komv,
           wa_display TYPE ty_display,
          WA_LFA1 TYPE TY_LFA1,
          W_GROSS_AMT type KOMV-KWERT,
           wa_subdebit TYPE ty_ekbe,
           wa_packno TYPE ty_services,
           wa_services TYPE ty_services,
           wa_konv TYPE ty_konv,
           wa_taxcom TYPE taxcom,
           wa_ls_fieldcat TYPE slis_fieldcat_alv.
    FIELD-SYMBOLS: Begin with FS_                                       *
    FIELD-GROUPS: Begin with FG_                                        *
    CONTROLS:                                                           *
    SELECT-OPTIONS: Begin with SO_                                      *
    SELECT-OPTIONS : so_lifnr FOR ekko-lifnr ,
                    so_mtart FOR ekpo-mtart,
                     so_ebeln FOR ekbe-ebeln,
                     so_matnr FOR ekbe-matnr,
                    so_date FOR sy-datum no-display,
                     do_date for ekko-bedat,
                     tax_code for ekpo-mwskz,
                     mr_date for ekbe-budat,
                     mat_gr for ekpo-matkl,
                     mat_tp for ekpo-mtart,
                     pr_plant for ekbe-werks,
                     pr_ekorg for ekko-ekorg.
    PARAMETERS: Begin with PR_                                          *
    *PARAMETER : pr_plant LIKE ekpo-werks . "OBLIGATORY.
               pr_ekorg LIKE ekko-ekorg . "OBLIGATORY.
    SELECTION-SCREEN : BEGIN OF BLOCK b1 WITH FRAME TITLE text-001 .
    PARAMETER : pr_preg TYPE c  radiobutton group g1  default 'X',
                pr_ror TYPE c  RADIOBUTTON GROUP g1 .
    SELECTION-SCREEN : END OF BLOCK b1.
    START-OF-SELECTION                                                  *
    START-OF-SELECTION .
    *--- Get the data reguired--
      PERFORM f001-get_data.
    *-------Calculate the tax required -
      PERFORM f002-cal_taxes.
      PERFORM miro_get_data.
    END-OF-SELECTION                                                    *
    END-OF-SELECTION.
    *---Display the report--
      PERFORM f003-display_register.
    *&      Form  F001-GET_DATA
          text
    -->  p1        text
    <--  p2        text
    FORM f001-get_data .
    Clear and Refresh all internal table and work area.
      REFRESH : it_ekko,
                it_ekbe,
                it_services,
                it_packno,
                it_konv,
                it_lfa1,
                it_komv.
      CLEAR   : wa_ekko,
                wa_ekbe,
                wa_services,
                wa_packno,
                wa_konv,
                wa_lfa1,
                wa_komv.
    Get the history records for all the selected PO. from table EKBE of
    type GR.
        IF pr_preg = 'X'.
    *Get Purchasing Document Number, Number of the document condition,
    *Vendor's accountNumber, Currency Key, Procedure , Country for Tax
    *ReturnPurchasing OrganizationExchange rate In an internal table it_ekko
    *break-point.
      SELECT pBSART qknttp pebeln pknumv plifnr pwaers pkalsm plands pekorg pwkurs
         wkurs pbedat  qebelp qbukrs qmatkl qmtart pllief qmeins qbprme
         qtxjcd qmwskz pwkurs qnetpr qmenge QPEINH
        INTO CORRESPONDING FIELDS OF TABLE it_ekko
        FROM   ekko AS p INNER JOIN ekpo AS q
               ON pebeln = qebeln
        WHERE   p~ekorg in pr_ekorg
                AND p~lifnr IN so_lifnr
            AND q~mtart IN so_mtart
                AND p~ebeln IN so_ebeln
                and p~bedat in do_date
                and q~mwskz in tax_code
                and q~matkl in mat_gr
                and q~mtart in mat_tp
                and kalsm = 'SIL000'
                AND EKORG = 'SDOP'.
           GET ALL THE PO FOR WHICH MIRO HAS BEEN DONE
      SELECT ebeln ebelp budat bldat werks
        INTO CORRESPONDING FIELDS OF TABLE it_ekbe1
        FROM ekbe
        FOR ALL ENTRIES IN it_ekko
        WHERE ebeln = it_ekko-ebeln
           AND ebelp = it_ekko-ebelp
           AND bewtp = 'Q'
           AND  werks in pr_plant
          AND budat IN so_date
          AND ( bwart = '101' OR bwart = '102'  ) "OR bwart = '105' OR bwart = '106' OR bwart ='')
           AND ebeln IN so_ebeln
           and budat in mr_date
           AND matnr IN so_matnr.
          AND ( BUDAT >= SO_DATE-low and BUDAT <= SO_DATE-high ).
    Check whether any records is present
      IF sy-subrc = 0.
          IF NOT it_ekbe1 IS INITIAL.
            SELECT ebeln ebelp buzei belnr budat xblnr werks matnr menge
                   dmbtr waers wrbtr bwtar shkzg dmbtr bldat srvpos
                   packno introw lfbnr bwart
                INTO CORRESPONDING FIELDS OF TABLE it_ekbe
                FROM  ekbe
                FOR ALL ENTRIES IN it_ekbe1
                WHERE      ebeln = it_ekbe1-ebeln
                        AND  ebelp = it_ekbe1-ebelp
                        and budat in mr_date
                       AND budat IN so_date
                 and  ( BUDAT >= SO_DATE-low and BUDAT <= SO_DATE-high )
                      AND  bewtp = 'Q'.
                    AND ( bwart = '101' OR bwart = '102' OR bwart = '103' OR bwart = '105' ). "OR bwart = '105' OR bwart = '106' OR bwart ='').
                     AND  bwart = '103'.
                 and  WERKS = PR_PLANT.
            IF sy-subrc = 0.
            ENDIF.
          ELSE.
            SELECT ebeln ebelp buzei belnr budat xblnr werks matnr menge
                  dmbtr waers wrbtr bwtar shkzg dmbtr bldat srvpos
                  packno introw lfbnr bwart
               INTO CORRESPONDING FIELDS OF TABLE it_ekbe
               FROM  ekbe
               FOR ALL ENTRIES IN it_ekbe1
               WHERE      ebeln = it_ekbe1-ebeln
                       AND  ebelp = it_ekbe1-ebelp
                       and budat in mr_date
                     AND budat IN so_date
                 and ( BUDAT >= SO_DATE-low and BUDAT <= SO_DATE-high )
                     AND  bewtp = 'Q'.
                    AND ( bwart = '101' OR bwart = '102' OR bwart = '103' OR bwart = '105' ) . "OR bwart = '105' OR bwart = '106' OR bwart ='').
                    AND  bwart = '102'.
                 and  WERKS = PR_PLANT.
            IF sy-subrc = 0.
            ENDIF.
            ENDIF.
        ENDIF.
    new code added
    *get the venor address
         select alifnr bname1 bpstlz bstras b~lifnr
         into corresponding fields of table it_LFA1
         from ekko as a inner join lfa1 as b
         on alifnr = blifnr
         for all entries in it_EKKO
         where  B~lifnr = it_EKKO-lifnr.
    ***tax code description added*******************
    select mwskz text1 spras kalsm
    from t007s
    into corresponding fields of table it_t007s for all entries in it_ekko
    where mwskz = it_ekko-mwskz and spras = 'E' and kalsm = 'TAXSIL'.
    *******vendor vat no. added*************
    select lifnr j_1icstno
    from j_1imovend
    into corresponding fields of table it_j_1imovend for all entries in it_ekko
    where lifnr = it_ekko-lifnr.
    **********gl code added******************************************
    *select lifnr shkzg dmbtr hkont
    *from bseg
    *into corresponding fields of table it_bseg for all entries in it_lfa1  " it_ekko
    *where  LIFNR = it_lfa1-LIFNR and shkzg = 'S'.
    *************gl code description added*******************************************
    *select saknr ktoks mcod1 sakan
    *from ska1
    *into corresponding fields of table it_ska1 for all entries in it_bseg
    *where sakan = it_bseg-hkont and ktoks = 'MAT'.
    Get the package number , service number , service text , net price ,
    accual amount , qty. etc
        IF NOT it_packno[] IS INITIAL.
          SELECT ppackno psrvpos pktext1 pnetwr pact_wert pmenge
              INTO CORRESPONDING FIELDS OF TABLE it_services
              FROM esll  AS p "inner join ESLL as Q
               on      PPLN_PACKNO = QPACKNO
                  and  PINTROW = QINTROW
              FOR ALL ENTRIES IN it_packno
              WHERE p~packno = it_packno-sub_packno.
          IF sy-subrc = 0.
          ENDIF.
        ENDIF.
    Get Number of the document condition ,line item number, Condition
    value for all selected PO.
        IF NOT it_ekko[] IS INITIAL.
          SELECT  knumv kposn kschl kwert
              INTO CORRESPONDING FIELDS OF TABLE it_konv
              FROM konv
              FOR ALL ENTRIES IN it_ekko
              WHERE  knumv = it_ekko-knumv.
          IF sy-subrc = 0.
          ENDIF.
        ENDIF.
      ENDIF.
    ENDFORM.                    " F001-GET_DATA
    *&      Form  F002-CAL_TAXES
          text
    -->  p1        text
    <--  p2        text
    FORM f002-cal_taxes .
    Calculate taxes for all the PO.
      LOOP AT it_ekbe INTO wa_ekbe.
        CLEAR :  wa_display,
                 wa_ekko.
        READ TABLE it_ekko WITH TABLE KEY ebeln = wa_ekbe-ebeln
                                          ebelp = wa_ekbe-ebelp
                                          INTO wa_ekko.
        IF sy-subrc = 0.
        ENDIF.
        CLEAR wa_taxcom.
    Get the text for the Material.
        SELECT SINGLE maktx
          INTO wa_display-maktx
          FROM  makt
          WHERE     matnr = wa_ekbe-matnr
                AND spras = sy-langu.
        wa_taxcom-bukrs = wa_ekko-bukrs.
        wa_taxcom-budat = wa_ekbe-bldat.
        wa_taxcom-budat = wa_ekko-bedat." change by dinesh
        wa_taxcom-waers = wa_ekbe-waers.
        wa_taxcom-kposn = wa_ekbe-ebelp.
        wa_taxcom-mwskz = wa_ekko-mwskz.
        wa_taxcom-txjcd = wa_ekko-txjcd.
       taxcom-shkzg = 'H'.
        wa_taxcom-xmwst = 'X'.
       IF ekko-bstyp EQ bstyp-best.
        wa_taxcom-wrbtr = wa_ekko-netpr * wa_ekbe-menge * wa_ekko-wkurs.
         WA_TAXCOM-WRBTR = wa_ekbe-dmbtr.
       ELSE.
         taxcom-wrbtr = ekpo-zwert.
       ENDIF.
        wa_taxcom-lifnr = wa_ekko-lifnr.
        wa_taxcom-land1 = wa_ekko-lands.                              "WIA
        wa_taxcom-ekorg = wa_ekko-ekorg.
        wa_taxcom-hwaer = 'INR'.    "t001-waers.
        wa_taxcom-llief = wa_ekko-llief.
        wa_taxcom-bldat = wa_ekbe-bldat.
        wa_taxcom-matnr = wa_ekbe-matnr.         "HTN-Abwicklung
        wa_taxcom-werks = wa_ekbe-werks.          "pr_plant.
          taxcom-bwtar = ekpo-bwtar.
        wa_taxcom-matkl = wa_ekko-matkl.
        wa_taxcom-meins = wa_ekko-meins.
        wa_taxcom-ebeln = wa_ekbe-ebeln.
        wa_taxcom-ebelp = wa_ekbe-ebelp.
        wa_taxcom-mglme = wa_ekbe-menge.
        wa_taxcom-mtart = wa_ekko-mtart.
    *Call function module CALCULATE_TAX_ITEM--
        CALL FUNCTION 'CALCULATE_TAX_ITEM'
          EXPORTING
            i_taxcom     = wa_taxcom
            display_only = 'X'
           dialog       = diakz
          IMPORTING
            e_taxcom     = wa_taxcom
           nav_anteil   = hwert
          TABLES
            t_xkomv = it_komv
          EXCEPTIONS
            OTHERS       = 01.
        IF sy-subrc = 0.
        ENDIF.
        wa_display-bsart = wa_ekko-bsart.
        wa_display-knttp = wa_ekko-knttp.
        wa_display-bprme = wa_ekko-bprme.
        wa_display-meins = wa_ekko-meins.
        wa_display-lifnr = wa_ekko-lifnr.
        wa_display-ebeln = wa_ekbe-ebeln.
        wa_display-bedat = wa_ekko-bedat.
        wa_display-bwart = wa_ekbe-bwart.
        wa_display-budat = wa_ekbe-budat.
        wa_display-matnr = wa_ekbe-matnr.
        wa_display-belnr = wa_ekbe-belnr.
        wa_display-menge = wa_ekbe-menge.
        wa_display-PEINH = wa_ekko-PEINH.
        wa_display-dmbtr = ( wa_ekko-netpr * wa_ekbe-menge * wa_ekko-wkurs ) / wa_ekko-PEINH.
      WA_DISPLAY-DMBTR = WA_EKBE-DMBTR.
        wa_display-srvpos = wa_ekbe-srvpos.
        wa_display-mwskz = wa_EKKO-mwskz.
        wa_display-WAERS = wa_EKKO-WAERS.
    read table it_lfa1 into wa_lfa1 with key lifnr = wa_ekko-lifnr.
    wa_display-name1 = wa_lfa1-name1.
    wa_display-pstlz = wa_lfa1-pstlz.
    wa_display-stras = wa_lfa1-stras.
    read table it_t007s into wa_t007s with key mwskz = wa_ekko-mwskz.
    wa_display-text1 = wa_t007s-text1.
    read table it_j_1imovend into wa_j_1imovend with key lifnr = wa_ekko-lifnr.
    wa_display-j_1icstno = wa_j_1imovend-j_1icstno.
    read table it_bseg into wa_bseg with key LIFNR = wa_lfa1-lifnr.  " wa_ekKO-LIFNR .
    wa_display-HKONT = wa_bseg-HKONT.
    *read table it_ska1 into wa_ska1 with key sakan = wa_bseg-hkont.
    *wa_display-mcod1 = wa_ska1-mcod1.
        READ TABLE it_komv WITH KEY kschl = 'JCDB'
                                    kposn = wa_ekko-ebelp
                                    INTO wa_komv.
        IF sy-subrc = 0.
          wa_display-custduty = wa_komv-kwert .
        ELSE.
          READ TABLE it_konv INTO wa_konv WITH KEY knumv = wa_ekko-knumv
                                                   kposn = wa_ekko-ebelp
                                                   kschl = 'JCDB'.
          IF  wa_ekko-menge <> 0.
            wa_display-custduty = ( wa_ekbe-menge / wa_ekko-menge
                                            ) * wa_konv-kwert * wa_ekko-wkurs.
          ENDIF.
        ENDIF.
    Get the BED OR EXCISE DUTY
         CLEAR :  wa_komv , wa_konv.
        READ TABLE it_komv WITH KEY kschl = 'JMOP'
                                    kposn = wa_ekko-ebelp
                                    INTO wa_komv.
        IF sy-subrc = 0 .
          wa_display-BED = wa_komv-kwert .
        ELSE.
          READ TABLE it_komv WITH KEY kschl = 'JMOQ'
                                      kposn = wa_ekko-ebelp
                                      INTO wa_komv.
          IF sy-subrc = 0.
            wa_display-BED = wa_komv-kwert .
          ELSE.
            READ TABLE it_konv INTO wa_konv WITH KEY knumv = wa_ekko-knumv
                                                  kposn = wa_ekko-ebelp
                                                  kschl = 'JMOP'.
            IF sy-subrc = 0.
              IF  wa_ekko-menge <> 0.
                wa_display-BED  = ( wa_ekbe-menge / wa_ekko-menge
                                            ) * wa_konv-kwert * wa_ekko-wkurs.
              ENDIF.
            ELSE.
              READ TABLE it_konv INTO wa_konv WITH KEY
                                                 knumv =  wa_ekko-knumv
                                                 kposn = wa_ekko-ebelp
                                                 kschl = 'JMOQ'.
              IF  wa_ekko-menge <> 0.
                wa_display-BED  = ( wa_ekbe-menge / wa_ekko-menge
                                            ) * wa_konv-kwert * wa_ekko-wkurs.
              ENDIF.
            ENDIF.
          ENDIF.
        ENDIF.
    ******END OF EXCISE DUTY AND THE BED******************************************************
    Get the  EDUCATION CESS
        CLEAR :  wa_komv , wa_konv.
        READ TABLE it_komv WITH KEY kschl = 'JEC1'
                                    kposn = wa_ekko-ebelp
                                    INTO wa_komv.
        IF sy-subrc = 0 .
          wa_display-educess = wa_komv-kwert .
        ELSE.
          READ TABLE it_komv WITH KEY kschl = 'JESQ'
                                      kposn = wa_ekko-ebelp
                                      INTO wa_komv.
          IF sy-subrc = 0.
            wa_display-educess = wa_komv-kwert .
          ELSE.
            READ TABLE it_konv INTO wa_konv WITH KEY knumv = wa_ekko-knumv
                                                  kposn = wa_ekko-ebelp
                                                  kschl = 'JEC1'.
            IF sy-subrc = 0.
              IF  wa_ekko-menge <> 0.
                wa_display-educess  = ( wa_ekbe-menge / wa_ekko-menge
                                            ) * wa_konv-kwert * wa_ekko-wkurs.
              ENDIF.
            ELSE.
              READ TABLE it_konv INTO wa_konv WITH KEY
                                                 knumv =  wa_ekko-knumv
                                                 kposn = wa_ekko-ebelp
                                                 kschl = 'JESQ'.
              IF  wa_ekko-menge <> 0.
                wa_display-educess  = ( wa_ekbe-menge / wa_ekko-menge
                                            ) * wa_konv-kwert * wa_ekko-wkurs.
              ENDIF.
            ENDIF.
          ENDIF.
        ENDIF.
    *END OF EDUCATION CESS
    Get the SERVICE TAX
        clear : WA_KOMV , WA_KONV.
        read table IT_KOMV with key KSCHL = 'JSRT'
                                    KPOSN = WA_EKKO-EBELP
                                    into WA_KOMV.
        if SY-SUBRC = 0.
          WA_DISPLAY-SERTAX  = WA_KOMV-KWERT .
        else.
          read table IT_KONV into WA_KONV with key KNUMV = WA_EKKO-KNUMV
                                                   KPOSN = WA_EKKO-EBELP
                                                   KSCHL = 'JSRT'.
          WA_DISPLAY-SERTAX  = WA_KONV-KWERT * wa_ekko-WKURS.
        endif.
    END OF SERVICE TAX****************************************
    Get the  EDUCATION CESS ON SERVICE TAX************************
        clear : WA_KOMV , WA_KONV.
        read table IT_KOMV with key KSCHL = 'JEC5'
                                    KPOSN = WA_EKKO-EBELP
                                    into WA_KOMV.
        if SY-SUBRC = 0.
          WA_DISPLAY-SEREDUCESS  = WA_KOMV-KWERT .
        else.
          read table IT_KONV into WA_KONV with key KNUMV = WA_EKKO-KNUMV
                                                   KPOSN = WA_EKKO-EBELP
                                                   KSCHL = 'JEC5'.
          WA_DISPLAY-SEREDUCESS  = WA_KONV-KWERT * wa_ekko-WKURS.
        endif.
    ******END OF SERVICE TAX ON EDUCATION CESS************************************************
    Get the CVD
        CLEAR : wa_komv , wa_konv.
        READ TABLE it_komv WITH KEY kschl = 'JCV1'
                                    kposn = wa_ekko-ebelp
                                    INTO wa_komv.
        IF sy-subrc = 0.
          wa_display-cvd  = wa_komv-kwert .
        ELSE.
          READ TABLE it_konv INTO wa_konv WITH KEY knumv = wa_ekko-knumv
                                                   kposn = wa_ekko-ebelp
                                                   kschl = 'JCV1'.
          IF  wa_ekko-menge <> 0.
            wa_display-cvd  = ( wa_ekbe-menge / wa_ekko-menge
                                            ) * wa_konv-kwert * wa_ekko-wkurs.
          ENDIF.
        ENDIF.
    Get the total INSURANCE
        CLEAR : wa_komv , wa_konv.
        READ TABLE it_komv WITH KEY kschl = 'ZIN1'
                                    kposn = wa_ekko-ebelp
                                    INTO wa_komv.
        IF sy-subrc = 0 .
          wa_display-insure = wa_komv-kwert .
        ELSE.
          READ TABLE it_komv WITH KEY kschl = 'ZIN2'
                                      kposn = wa_ekko-ebelp
                                      INTO wa_komv.
          IF sy-subrc = 0.
            wa_display-insure = wa_komv-kwert .
          ELSE.
            READ TABLE it_konv INTO wa_konv WITH KEY knumv = wa_ekko-knumv
                                                  kposn = wa_ekko-ebelp
                                                  kschl = 'ZIN1'.
            IF sy-subrc = 0.
              IF  wa_ekko-menge <> 0.
                wa_display-insure  = ( wa_ekbe-menge / wa_ekko-menge
                                            ) * wa_konv-kwert * wa_ekko-wkurs.
              ENDIF.
            ELSE.
              READ TABLE it_konv INTO wa_konv WITH KEY
                                     

    Hi Ingo,
    Thanks for the reply. But let me rephrase my question.  In the Bex we get a extra row called overall result in the result set which gives the correct  count/total/average based on exception aggregation.  The question is how we show the overall result row in the crystal or rather how can we map it into crystal.  So i thought as of now we should create a formula to compute the overall result and display it.
    Hope I am clear this time in asking the right question.
    Many many thanks in advance for your reply.
    Kind regards,
    Shiva.

  • How to compare dates in Crystal Reports 2008

    Hello,
    I cannot figure out how to compare the dates in the Crystal reports.
    I need all dates that are in the future to be displayed with the green font.
    So in the formula for the font for this texbox I've tried to use different
    formulas like:
    If DateDiff("d", CurrentDate, {DevelopmentTracking_SELECT.Anticipated}) > 1
    Then
         crGreen
    or
    If {DevelopmentTracking_SELECT.Anticipated} > CurrentDate Then
         crGreen
    (where DevelopmentTracking_SELECT is the stored procedure, and Anticipated
    is a date field).
    None of them worked. All dates are treated like they were in the past
    comparing to the CurrentDate. If I reverse these formulas like:
    If {DevelopmentTracking_SELECT.Anticipated} < CurrentDate Then
         crGreen
    then all dates turn to green, otherwise they always stay black.
    What could be a problem here?
    I would appreciate your help.
    Thank you.

    OK, got it, thank you. It worked.
    However, I also need to use another field value which is not on the report, like this:
    If CurrentFieldValue < CurrentDate And {DevelopmentTracking_SELECT.Completed} = False Then
    crRed
    DevelopmentTracking_SELECT.Completed is not on the report.
    Is it possible to use it with the cross-tab?

  • Crystal Reports Pie Chart showing Sum 100% in Legend.  How to remove?

    I have a Pie chart which displays correctly but in the Legend is displayed the values with the correct percentages AND  the Sum showing 100%.
    I need to either remove the Sum line or be able to change the text from the report since I have to produce the report in 4 languages and the Sum always shows up in the language of the server.
    the legend looks something like;
    value1  25%
    value2  25%
    value3  75%
    Sum     100%   <------  this line must go or be changed  (e.g. in Italian as Totale)
    Running a server for each language is not an option
    There are a variable number of values so I cannot overlay a rectangle on a fixed position.  (awfull solution)
    Is there any way I can simply turn off the Summ (not the whole legend which is needed)?
    any help would be greatly appreciated.
    I am using Crystal Reports 2008
    Best Regards
    Chris Ryder

    Well  Thank you everyone for your suggestions.
    The client is very specific about the look and feel so I cannot change to not using a legend.  However,  the discussions serves to confirm that it is NOT possible which is actually just as useful.
    In Conclusion
    To restate the problem  the client has a report which can be displayed in one of four languages by choice from the end user.  The report contains a pie chart which displays the various segment names and percentages as a legend.  At the bottom of this legend appears automaticaly the word Summ in the langauge of the the 'Server Locale' (in our case german Summe) and the 100% value.
    I wished to know if it was possible to either change the language of this word (without changing the server as I do not have access) or to remove it altogether.
    The answer is NO it is not possible to remove only this word or to change it in anyway.
    Our final workaround is;
    we hide the Legend on the graph and build it as a seperate entity next to the graph.  Not ideal as everything is then done twice and we have an indirect link between the segment colours and the legend colours which is not apparent directly in the report.  But at least the client has signed off on the report.
    once again thank you for taking the time to think about the problem.
    Chris Ryder

  • Reverse sign +/- in a hierarchy

    Hi all
    I need to subtract just one node of a hierarchy. So I ticked the flag reverse sign +/-, and then I set the node I need to be changed.
    The problem is that it doesn´t work. My node sign is not reversed as I expected.
    Should I do anything else?
    thks in advance

    No, what I want to say is this:
    I have a hierarchy and I need to subtrac one node (I need to change the sign), so in maintenance infoobject I tick the option reverse sign of a node.
    the value of my node is -100 and after ticked reverse sign +/- for this node in my hierarchy, when I execute my report the value is -100 instead of 100.
    I don´t know why this is not working.

Maybe you are looking for

  • How to add an AP to a Controller

    Hello,  I'm not familiar with the process of how to add an access point to a controller. DHCP with option 43 has been configured for the subnet where the AP will be installed. The AP has obtained an IP address and I'd like to know how to discover it

  • File-idoc     Unable to convert the sender service  to an ALE logical syste

    Hi experts iam working on file-idoc scenario ,iam getting the below error in sxmb_moni and RWB "Unable to convert the sender service  to an ALE logical system" i checked the partnetr profile, RFC(sm59) and IDX1 t codes. the connection is ok. but stil

  • Firmware 4.0750.31.2.1

    hi friends, i am having n73 ME with FW v3.0638.0.0.30 on update site www.europe.nokia.com/softwareupdate it shows the latest FW available is v4.0750.31.2.1 for product code product code 0543843 is it advisable to upgrade to v4.0750.31.2.1 please help

  • Database connectivity questions

    I have a site made in CS3 that uses db connectivity and works fine.  Now I'm in CS5 and need to add some dynamic pages to it.  The site already has a DSN and works. I don't know if I've just forgotten in the last few years how to do it or if somethin

  • Issue: No aut determination of Picking request during delivery creation

    Hi! I have created a new shipping point as copy of existing shipping point. Issue is that for this new shipping point deliveries are created but not the picking request. I can not find any difference in the set up w/regards to: Plant Storage Location