RFC connection for nonSAP system

Hi all
i want to send and receive data from b/w SAP and NON-SAP systems. plz tell me which type of RFC connection i will use.
Regard
Imran Khan

Imran,
Check the attached link.
[https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/50d69314-1be0-2b10-11ab-8045021f0c3a]
Manoj

Similar Messages

  • No trusted/login RFC connection for system BCP in TA SMSY

    Hi,
    i got this error  Early Watch Report  for only production System.
    No trusted/login RFC connection for system BCP in TA SMSY
    Amit

    HI,
    I hope the error message is straight forward.
    Please Check whether you have established RFC connections to the BPC system and the same is avaiable under the RFC connections in TRXn SMSY-Your system -.Test the connections in SM59-BPCs-> READ and Trusted RFCs.
    If its not present, Generate the RFCs again manually.
    Hope this helps.
    Revert for any issues.
    Thanks,
    Jagan
    Edited by: jagadheeshan govindasamy on Oct 9, 2009 3:24 PM

  • WHY do we set up a RFC connection for workflows

    Guys please tell me why do we setup a RFC connection for workflows.
    I am getting few dumps for function module IDOC_ERROR_WORKFLOW_START_R in transsactional RFC connection.
    Looks like it is because of temporary disconnection.
    i want to know what is the relationship of RFC with wirkflows.
    Thanks in advance

    Quoting text in automatic WF customizing transaction (SWU3):
    Function
    The workflow runtime system always executes its tRFC (transactional RFC) calls on the logical destination WORKFLOW_LOCAL_xxx (xxx stands for the three-digit number of the client).
    The workflow runtime system only operates within one client. The naming for the logical destination guarantees that these names are unique across the system.
    If you carry out this activity automatically, the logical RFC destination WORKFLOW_LOCAL_xxx is created (if it does not already exist). The user WF-BATCH (system user) is assigned to this destination.
    If you belong to the SUPER user group, and the WF-BATCH user does not exist, it is created and automatically gets the maximum authorization of the current user (SY-UNAME). This function is to be performed once by a user who belongs to the SUPER user group.
    If you perform this activity manually, you can maintain another system user and another password.
    In SWU3 you can configure RFC destination.

  • How to setup RFC Connection for SAPOSS?

    Dear Experts,
    I tried to setup the RFC connection for SAPOSS based on the following settings, but when I test connection, it failed.
    Target system : OSS
    Msg. Server : ... ( this where I stuck which I'm not sure what to fill in)
    Group : EWA
    Client : 001
    User : OSS_RFC
    Password : CPIC
    Does anyone know the right settings?
    Regards,
    Abraham

    Hi all,
    Do I really need to setup our own SAProuter if our firewall doesn't block any outbound IP address?
    I've tried the following settings in OSS1 but still failed to connect.
    SAProuter at SAP :-
    Name : sapserv3 ( or sapserv7 or sapserv2)
    IP address : 147.204.2.5   (or 194.39.134.35 or 194.39.131.34)
    Instance no : 99
    SAPNet Message Server
    Name : oss001
    DB Name : 001
    Instance No : 01
    I left the SAProuter1 and SAProuter2 (at customer site) blank.
    Did I miss out anything?

  • RFC connection to source system ABPCLNT310 is damaged

    Hello,
    I'm importing a transport in BW Prod (condition type data for billing and orders), but receive this error message in STMS:
    The creation of the export DataSource failed
    Reading the Metadata of 0SD_O05 ...
    Creating DataSource 80SD_O05 ...
    RFC connection to source system ABPCLNT310 is damaged ==> no Metadata upload
    RFC connection to source system ABPCLNT310 is damaged ==> no Metadata upload
    Error when creating the export DataSource and dependent Objects
    Error when activating ODS-objekt 0SD_O05
    The creation of the export DataSource failed
    The import worked fine in BW QA system. Why do I get this error? It is possible to manually generate the export data source from the ODS object, but when I try to import again, it once again fails...
    Best regards,
    Fredrik

    hi Fredrik,
    check if helps oss note 597326, 886102, 184322
    RFC connection to source system Damaged
    Error when transporting ODS Object
    597326 - Activating ODS: Error when creating the export DataSource
    Symptom
    When you activate or transport ODS objects, the following errors appear in the log:
    "The creation of the export DataSource failed". Message number RSBM 035
    "Error &1 in function module &2". Message number RSBM 006
    "Error when creating the export DataSource and dependent Objects". Message number RSDODSO 169
    "Error when activating the ODS object &1". Message number RSDODSO 168
    Other terms
    RSBM 035, RSBM 006, RSDODSO 169, RSDODSO 168
    Reason and Prerequisites
    A characteristic involved is active but it is using new or inactive attributes.
    Characteristics involved are all characteristics used in the ODS object.
    Solution
    Check all characteristics involved as described in the following:
    Check the Compounding and Attributes tabs in the characteristics maintenance.
    All characteristics here must be active. This is displayed by a green icon.
    If this is not the case for a characteristic involved (a gray icon is displayed on one of the two tabs), activate the characteristic involved. This also activates the inactive dependent characteristics.
    After you have checked and repaired all the characteristics involved as described above, the loading/maintenance of master data should work again

  • Unable to open RFC connection to SAP System NSP

    Hi all,
    During installation i am getting an error which is as follows,
    "Unable to open RFC connection to SAP System NSP.
    Solution: Start the system."
    And the second problem is that there are no connections shown in SAPGUI.
    Please help me out.
    Thanking you,
    Kranthi

    HI Kranthi,
    Have you checked this thread NW Preview Installation error?
    Regards

  • RFC connection to source system is damaged , no Metadata uploaded

    Hello Friends,
    I need your help to understand and rectify why my transport is failing again and again.
    RFC connection to source system BT1CLNT200 is damaged ==> no Metadata upload
    Environment - Production Support (Dev - Quality - Testing - Production)
    Alive scenario - Need to create two InfoObject and incorporate the fields in to data targets and reports.
    What we have did?
    1st request - We have created new request and captured two Infoobjects in to the request.
    2nd Request - We have captured the replicated Datasource along with that the below sequence displayed by default in the same package.
    Communication structure
    DataSource Replica
    Transfer Rules
    InfoSource transaction data
    Transfer structure
    3rd Request - we have captured DSO and Cube only in this request.
    4th Request - Captured 2 update rules (ODS) Update Rule (Cube)
    The above 3rd request failed in the testing system (successful in Quality System) and ODS is inactive in the Testing system.
    Testing system Error Message:
    The creation of the export DataSource failed
    RFC connection to source system BT1CLNT200 is damaged ==> no Metadata uploa
    RFC connection to source system BT1CLNT200 is damaged ==> no Metadata uploa
    Error when creating the export DataSource and dependent Objects
    Error when activating ODS Object ZEOINV09
    Error/warning in dict. activator, detailed log    > Detail
    Structure change at field level (convert table /BIC/AZEOINV0900)
    Table /BIC/AZEOINV0900 could not be activated
    Return code..............: 8
    Following tables must be converted
    DDIC Object TABL /BIC/AZEOINV0900 has not been activated
    Error when resetting ODS Object ZEOINV09 to the active version
    So we have captured the data mart Datasource and created a new( 5th ) request (transported only 5th request )and transported in the below sequence
    Communication structure
    Datasource Replica
    Transfer Rules
    Infosource transaction data
    Transfer structure
    development to Quality - Successfully
    Failed in testing system again.
    How to rectify this error, please help us
    Thanks,
    Nithi.

    Hello All,
    *Question -1*
    I have checked the connections and typed the steps below - what i have seen in the screen.
    Steps :
    R/3 Connection - I have double clicked on the BT1CLNTXXX and tested the connections.
    Connection Type :
    Logon - 0KB , 10 KB , 20KB, 30 KB
    R/3 connection:
    5 msec, 0msec, 1msec,1msec,1msec
    Please let me know whether RFC connection is OK or not.
    Question - 2
    I want to know is there is any option to check before transporting the TR from Developement to Quality - "Preview Check " the sequence , so that we can avoid the Transport failure because of TR sequence.
    Regards,
    Nithi.

  • Couldn't create jco client connection for logical system

    Dear Experts,
    we are facing a strange issue in our custom webdynpro java application, few of our portal users are getting the "couldn't create jco client connection for logical system" for Model Data JCO Destination. below are details
    1. portal version 7.02 SP14 (we have recently updated to SP14 from SP02-- is this is causing the issue ?)
         1.1. updated the NWDI track with SP14 SCA files as well as added latest WD Runtime SCA file deployed the applications to Production also.
    2. above said exception is inconsistent and happening for only few users
    3. ping and test of jco destinations are successfull in content administration as well as in SLD, destinations were added in the SLD system.
    4. cleared the JCO ARFC meta data cache in webdynpro console
    5. jco destinations are configured using uid/pwd, configured user is not locked active and tested in the backend by logging in with the same user.
    6. restarted the portal server
    even though, we are getting the above said exception for few of portal users randomly.
    Please help me on this ASAP, as i am not getting any further help on this.
    Thanks,
    Ram.

    Hello Ram,
    Check the JCo Pool Configuration settings of your JCO Destination. This message normally comes when the maximum connections has been reached. Increase the "Maximum Connections" to some number depending on the usage. A good habit is to disconnect the jco connection after executing the same in your webdynpro code if you don't want it to be synchronous.
    <ModelName>.modelInstance().disconnectIfAlive()
    Hope this helps.
    Regards
    Vijay

  • EWA Reporting for NONSAP Systems

    Hi all,
    we need an EWA reporting for NONSAP systems. Is it possible to generate EWA Reports containing OS information (like CPU Utilization, Memory consumption, Filesystems ...) from the monitored systems.
    If possible , are there any "How to guides" for implementing the NONSAP system in SMSY.
    Thanks in advance for your help.
    Regards
    Anton Brehm

    Hello,
    I would refere you to SAP Note 1257308 - FAQ: Using EarlyWatch Alerts
    If you look at section 1. Products and components for whcih teh EarlyWatch Alert is Available, the answer to your question is there, and states the products under section 1.1 and the components under section 1.2.
    This should clarify the answer for you.
    Regards,
    Paul

  • Creating RFC Destination For UNICODE system From NON-UNICODE system

    hi
    how can i create RFC Destination For UNICODE system( XI ) From NON-UNICODE (R/3) system.
    thanks and regards
    Mithlesh Kumar Jha

    Hi,
    Check these blogs , Hope u would be getting some idea
    <b>/people/thomas.jung3/blog/2004/06/24/bsp-150-a-developer146s-journal-part-v-xml-for-rfcs
    /people/thomas.jung3/blog/2004/11/15/bsp-150-a-developer146s-journal-part-xiii-developing-abap-webservices
    /people/sap.user72/blog/2004/06/19/how-i-started-with-sap-web-development</b>
    Regards,
    Sridhar Reddy

  • Clarification on RFC connections for MM-SUS set up in SRM

    Hi All,
    I am stuck with replication of vendor from R/3 to SUS. I have made the RFC connections as mentioned below
    R/3 Side: R/3 to XI - Type 3
    SUS Side: SUS to R/3 - Type 3
                    SUS to XI (LCRSAPRFC) - Type T
                    SUS to XI (SAPSLDAPI) - Type T
                    SUS to XI - Type H
    XI Side: XI to R/3 - Type 3
                XI to SUS (LCRSAPRFC) - Type T
                XI to SUS (SAPSLDAPI)  -  Type T
    Can you please confirm whether these connections are sufficient for MM-SUS set up.
    Thanks in advance!
    Regards,
    Ram
    Edited by: Ram K on Sep 21, 2008 10:16 AM

    Hi Ram,
    Vendor Master data R/3 to SRM
    1.Find the vendor group in  SRM
    TC= PPOMV_BBP
    Ex:- VG Id= 50000041
    2.TC= BBPGETVD     in  SRM
    Give the following parameters
    System(R/3), Vendor no in R/3, Pur. Org, Object ID:50000041
    Then  click on start transfer.
    3.TC= SLG1   Check the Q if have strucked
    4.Check the vendor no in SRM System use TC= PPOMV_BBP
    Note:-
    R/3 & SRM number range shoul be same
    R/3 internal/External No. range equal to SRM External number, Then only replicated
    If u need more details pls contact to my Id bvnvrao yahoo.com.
    I will forward screen shot document.
    I think it will help.
    WR
    Rao

  • Configuring RFC connections for load balancing.

    Hi ,
    We have the following landscape for our systems.
    The database is installed on z/os , db2 (mainframe). The central services( SCS and ASCS) are also on the mainframe. So the message server is on mainframe.
    The CI is on AIX and The DI is on AIX.
    We have Logon groups configured and load balancing Configured and is RFC enabled.
    1) When we connect to SAP using the SAPGUI and  the portal connection is made to either CI or DI depending upon the best response times.  Now recently we are running the mercury load testing, all the users are connecting to DI. Why are the users connecting to DI even though we have load balancing?
    2) I have a system with SID BP0, with one CI and one DI. The logon group is BP0 and the message server name is cyrix. Now I have other another system EP0. I have created a RFC connection from EP0 to BP0. In SM59 I have selected the load balancing option, and provide the message server name, SID and logon group name. The connection does not work. If I connect directly to the CI or DI the connection works. Please tell me how can I configure load balancing for RFC connections.
    Thanks
    Manmath.

    Dear 917996,
    There are two types of load balancing:
    - Client-side load balancing (setting up the tnsnames.ora on client side). More information here (http://ggsig.blogspot.co.uk/2012/04/client-side-
    load-balancing-in-oracle.html). Very good video produced my friend Igor Melnikov is here (http://www.dsvolk.ru/oracle/racdd4d/demos/video/loadbalance/client/clientloadbalance_viewlet_swf.html)
    -Server-side load balancing (remote_listener and setting service parameter clb_goal). Very good Igor Melnikov's video is here (http://www.dsvolk.ru/oracle/racdd4d/demos/video/loadbalance/server/serverloadbalance_viewlet_swf.html).
    I have read about client side and server side load balancing. By editing tnsnames.ora I have enabled client side load balancing which is suppose to select listeners at random. then why does it only go to second node?Could you please show your tnsnames.ora on client?
    Please can anyone help me to configure server side load balancing with SCAN. I have read many many post but couldn't find a clear answer.Based on your output (remote_listener string cmbtrnrac-scan:1521) you have already configured the server side load balancing.
    SQL> show parameter listener
    NAME TYPE VALUE
    listener_networks string
    local_listener string (DESCRIPTION=(ADDRESS_LIST=(AD
    DRESS=(PROTOCOL=TCP)(HOST=10.1
    7.67.214)(PORT=1521))))
    remote_listener string cmbtrnrac-scan:1521How many SCANs do you use? Do you use DNS?
    regards,
    Gennady

  • RFC User for satellite systems

    Hello Gurus,
    I just wanted to ask about one issue. We are a SAP partner and using Solution Manager in VARs scenario. There are many systems of our customers connected to our Solution Manager..
    Now I want to ask about RFC user(s). As I see, in our Solution Manager there are many users(communications type C) with Synthax SOLMAN<system id> or something like that. It means basically, that we have for every particular customerS system one SOLMAN user for RFC(cust_scout) in our Solution Manager. My question is if we can replace all of these users with only one RFC user for all the systems and customers?
    Many thanks in advance for your help
    Miloslav Pudil
    IDS Scheer
    Prague
    Czech Republic

    >
    Miloslav Pudil wrote:
    > I just wanted to ask about one issue. We are a SAP partner and using Solution Manager in VARs scenario. There are many systems of our customers connected to our Solution Manager..
    > Now I want to ask about RFC user(s). As I see, in our Solution Manager there are many users(communications type C) with Synthax SOLMAN<system id> or something like that. It means basically, that we have for every particular customerS system one SOLMAN user for RFC(cust_scout) in our Solution Manager. My question is if we can replace all of these users with only one RFC user for all the systems and customers?
    Hi Miloslav,
    Technically, it will work that you define one common RFC user in your SolMan for communication (RFC BACK destination) from all connected managed systems.
    BUT, I would never recommend it.
    Once a managed system cause issues in your SolMan, you are not able (or at least it's much more difficult) to identify the managed system. Same happens, if a invalid password in the BACK destination leads to a locked user.
    My recommendation: Spend the extra effort in creating a user per managed system. Operation will be much easier later.
    See also this guide:
    [Activating EarlyWatch Alert [EWA] in End Customeru2019s System |http://service.sap.com/~form/sapnet?_SHORTKEY=00200797470000089947&_OBJECT=011000358700000567342009E]
    Best regards,
    Ruediger

  • Connection with Nonsap System

    Dear All ,
    Can We connect the Solman to nonsap systems.

    Yes
    how to create system for non sap and non abap
    http://help.sap.com/saphelp_sm32/helpdata/en/a9/33482d238eac4ab9ab9596c9c0afd6/frameset.htm
    trans smsy
    Specify main instance of non-ABAP SAP and non-SAP products
           1.      Select the system for which you want to specify main instances, and set the Relevant flag for the relevant main instances, in the Main Instance Selection tab.
    The system copies the selected main instances into the left-hand screen area, under the system.
           2.      Select the main instance and enter the required data at the right-hand side of the screen.
           3.      Save your entries.
    Pls check service.sap.com too.
    Regards
    Prakhar
    Edited by: Prakhar Saxena on Feb 20, 2009 10:33 AM

  • RFC Connection for HR

    Hi,
    I'm trying to create a rfc connection between hr client and custimizing client for other modules. but is SALE when I'm trying to distribute my distribution model I always face this error:
    "name or password is incorrect".
    I changed the RFC password and my communication user many times but it didn't work. would you please tell me what is the problem?

    Create an 8 character long password which is all in UPPER CASE letters and change the user type to SYSTEM.
    Does that work?
    Cheers,
    Julius
    ps: see RZ11 param: login/password_downwards_compatibility for background to why I am asking.
    Edited by: Julius Bussche on May 31, 2011 5:02 PM

Maybe you are looking for