RFC Destination from CE is unwantedly using SSO

Hi,
Our developers are testing some services from Service Browser in CE 7.11 system. They are using the RFC Destination SAP_ECC which we have created from NWA --> Configuration Management --> Security --> Destinations.
In this RFC, we have given the details of the backend ECC system and also selected the user type as "Technical User" and provided a user/password. Pinging the destination from here works just fine.
But, when one of our services from Service Browser calls this destination SAP_ECC to access the backend system, then the call is not connecting to the backend using the technical user supplied in the destination, but is trying to use SSO. Thus the user being passed is not the technical user but the user of the developer who is calling the service. The error message says:
This system rejects all logons using SSO tickets
We do not have any intention of using SSO here.
Can someone suggest how to figure out why SSO is coming into picture and what can we do to elimincate this issue?
Thanks,
Shitij

set the sso parameters in the backend.

Similar Messages

  • HOw to find out the RFC destination from BW system to ISU

    Hi,
    Currently my requirement is to call a function module which is written in ISU (remote enabled) from BW system.
    I am unable to find out the rfc destination from BW to ISU system.
    In CRM we have table like smofparsfa1. Is there any table in BW which can provide me the ISU destination?
    I need to compare the records stored in isu as well as in BW system.
    I need to call a function module which will provide me the data from isu.
    please help me in this regard.
    Krishna

    Hi,
    You can check it in SM59 if there are any RFC destinations for the above systems.
    Alternatively ,check the table RFCDEST if any entries are maintained
    Regards,
    Lakshman.

  • RFC destination from XI ABAP engine to 4.5 B system

    I tried to create an RFC destination from XI ABAP engine to 4.5 B system.
    It does not work and gives an error.
    <b>Error Details     DETAIL: NiIGetSockName</b>
    -Naveen.

    Hi Naveen,
    First of all try to ping 4.5B system from XI system (Through TELNET)... This is to ensure the connectivity and the access. The error is not a common error, i suppose, So better first we check the phisical connectivity...
    Plz. confirm...
    Regards,
    Audy

  • Pass RFC destination from Portal

    Hello all:
    I am developing a webdynpro abap application, and i have to pass RFC destination from protal to MY webdynpro abap applcation.
    Could some one pelase let me know how to acheive this.
    Thanks,
    Ratna.

    and i have to pass RFC destination from protal to MY webdynpro abap applcation.
    Hi.,
    I didnt get u.  If you want to pass a parameter dynamically from Portal check this Article : [How to integrate Web dynpro in ABAP and pass Parameters to WDA.|http://www.sdn.sap.com/irj/scn/index?rid=/library/uuid/008fc414-997f-2e10-3899-fd895ec8eb5e]
    hope this helps u.,
    Thanks & Regards,
    Kiran

  • Export or transport all the RFC destination from one system to another syst

    Hi
    Is there any method to Export or transport all the RFC destination from one system to another system

    Hi,
    the information is stored in table rfcdes.But there are also some other RFC*-tables which have some relations. Nevertheless the RFC-connectons will possibly not work anymore  in the new system(depending on the release your systems are), as the passwords are stored in the Sec store with system-dependent keys.
    b.rgds, Bernhard

  • Error message when calling a Business Connector RFC destination from SRM

    Hello all,
    We are facing one problem with data Purchase Order transmission between SRM 5.0 (SRM_SERVER 5.5, extended classic scenario) and Business Connector 4.7.
    We made needed customizing in order to have "XML / XI" output medium available in tab 'Company Data' in "Manage Business Partners" web transaction (by updating BBP_USE_AI table in SM30 transaction).
    Then, we implemented BAdI definition BBP_EBPXML_OUT_BADI with method PURCHASEORDER in order to change XI system type to Business Connector.
    In this way, PO transfer data between SRM and BC is done using BC Module Function BAPI_POEC_XML_SEND (TCP/IP RFC connection was defined for Purchase Order in BBPC_RFCDEST table).
    Nevertheless, even if method BBP_PO_SEND_XML is correctly triggered when PO is created with a vendor with XML output medium, we have in the document output log ("Process Purchase Order" web transaction) an error message:
    ' Error (Unknown Partner and Message Type. Routing Rule created. Sender: SMR Receiver:) when calling RFC destination BC '
    where SRM is the SRM log. sys. and BC the Business Connector log. sys.
    Our EAI team is working on it, but if you have any idea, your are welcome !
    Thank you in advance.
    Regards.
    Laurent

    Hello Christian,
    Thank you for your help. However, we abandoned this solution between SRM and Business Connector.
    So, we followed instructions indicated in OSS note 883693 - "ECS: PO output determination in R/3".
    Nevertheless, in order to restrict this behaviour for specific vendors and purchasing organizations, we added some filters.
    It is working fine.
    However, when the PO is modified in SRM, then order again, PO is modified in R/3 (by the RFC user from SRM) more than once.
    As a consequence, we have as much messages as modifications of the order in R/3 (due to multiple RFC access with the SRM RFC user).
    Does anybody have an idea to have only one R/3 output message when the PO is modified in SRM ?
    One solution could be to check in the NAST table if the time creation of the last output message is lower than, for example, one minute.
    If it is the case, we do not allow R/3 ouput message.
    Any suggestions is welcome.
    Regards.
    Laurent.

  • RFC Destination of TCP/IP type :: Using Explicit Host Option

    Hi
    We need to call the executable file in an External non-sap system.
    We created the RFC detination for this & follow below steps -->
    *) Create RFC Destination of type TCP/IP
    *) Select option " <i>Start Explicit Host</i> "
    *) In Program parameter provide the path & name of the executable file e.g c:\windows\notepad.exe
    *) In Target Host providing the name of non-sap system.
    But while using Test Connection we are getting following error -->
    <b>ERROR timeout during allocate
    LOCATION SAP-Gateway on host clxstst02 / sapgw00
    DETAIL no connect of TP net from host CLWBRIDGE after 22 sec
    COMPONENT SAP-Gateway
    COUNTER 34
    MODULE gwr3cpic.c
    LINE 1785
    RETURN CODE 242
    SUBRC 0
    RELEASE 640
    TIME Thu Dec 14 15:28:33 2006
    VERSION 2</b>
    Pls. suggest what needs to be done.
    Regards
    - Lalit -

    Hello Lalit,
    Even though DNS is used you may have to have entires in host file.
    Suppose the SAP server is A and the PC is B.
    The the hostname/IP address for B should be maintained in A and vice versa should also happen.
    Also check if you are able to ping the PC from the SAP servers and vice versa.
    Regards.
    Ruchit.

  • RFC  destination from XI instance to R/3 instance.

    Hi
        This is sekhar i am searching for a job and while practicing XI i am not able to connect to the R/3
    while from R/3 i can able to connect to XI  instance as iam not concerned about basis can give any suggestion to solve it out

    hi raj
    see the below link:
    Is it possible to use the RFC sender adapter for asynchronous calls?    Async call
    http://help.sap.com/saphelp_nw04/helpdata/en/f6/e002416225f023e10000000a155106/frameset.htm
    http://help.sap.com/saphelp_nw04s/helpdata/en/f6/daea401675752ae10000000a155106/frameset.htm
    http://expertanswercenter.techtarget.com/eac/knowledgebaseAnswer/0,295199,sid63_gci983752,00.html
    <a href="http://File to RFC using BPM-Starter Kit: By Arpit Seth">http://File to RFC using BPM-Starter Kit: By Arpit Seth</a>
    reward points if helpful
    regards
    sreeni

  • How to get the RFC destination from logical system

    Dear all  ,
      i am working on one system and want to fetch data from another R3 sys
      i have written call ' FM' dest 'HPCR3' where HPCR3 is hardcoded.
      now if i want to remove the hardcoding i need to find out the RFC dest ( HPCR3)
      form logical sys(HPCPPT100) .
      i have used FM LOG_SYSTEM_GET_RFC_DESTINATION but not working
      kindly help
    Tarang

    hi,
    goto SM59 -> click on create rfc -> define rfc of receiver -> save -> give target host n system no -> give user id n password -> clicko n test connection -> if yes [u ll get info of remote connection ] -> remote login -> u can get intial screen of remote system.
    if helpful reward some points.
    with regards,
    Suresh Aluri.

  • CPI-C ERROR CM_PRODU while creating RFC destination from BW to R/3

    hi,
    i am trying to create connection between R/3 and BW and getting the error -
    partner not reached/ CPI-C ERROR CM_PRODU.
    could anybody plz. help.
    thanks, sunil.

    Hi,
    I think is because the SAP gateway host is deactivated.
    As per SAP notes, issue statement ping <IP address> (In this example:192.168.4.2) No reply: Boot SAP Gateway host required.
    An answer:Check whether the TCP/IP port 33xx is open (where xx corresponds to the system number) and start the SAP gateway.
    The TCP/IP port is also partially defined in the services file as an sapgw<SID> or sapgwxx entry (where xx corresponds to the system number). The services file is in the Windows directory or in WinNT/System32/drivers/etc.
    Rgs
    Antonino

  • RFC call from Excel using VBA

    I am trying to do an RFC call from Excel to SAP using VBA. RFC is working fine for most the RFC enabled Function Modules except DDIF_FIELDINFO_GET and DDIF_FIELDLABEL_GET.
    What can be the reason for this?
    Can someonme please help me with a macro code where these FMs are working.
    Also can someone please help me with some tutorial on SAP connection with Excel.
    <REMOVED BY MODERATOR - REQUEST OR OFFER POINTS ARE FORBIDDEN>
    Edited by: Alvaro Tejada Galindo on Nov 12, 2008 9:14 AM

    Hello Jon.
    DDIF_FIELDINFO_GET is not working for me either. But I have used another FM (/ZOPTION/LIVE_DDIF_FIELDINFO):
    Public Sub RFC_FIELDINFO()
    Dim Func As Object
    Dim sapConn As Object
    Dim tblFIELDTAB
    Dim tblFIXED_VALUES
    Dim intRow%
    Dim intCol%
    '* Sub     : Call FM /ZOPTION/LIVE_DDIF_FIELDINFO                         *
    '* Author  : Holger Köhn                                                  *
    '* Created : 23.08.2014                                                   *
    '* Changed :                                                              *
    ThisWorkbook.Sheets("TEST").Activate
    Cells.Select
    Selection.ClearContents
    ThisWorkbook.Sheets("TEST").Range("A1").Select
    '* create RFC-Connection                                                  *
    Set sapConn = CreateObject("SAP.Functions")
    sapConn.Connection.RfcWithDialog = True
    If sapConn.Connection.LogOn(1, False) <> True Then
        MsgBox "Cannot Logon to SAP"
        Exit Sub
    End If
    DoEvents
    '* run FM /ZOPTION/LIVE_DDIF_FIELDINFO                                    *
    Set Func = sapConn.Add("/ZOPTION/LIVE_DDIF_FIELDINFO")
    Func.Exports("TABNAME") = "AUFK"
    Set tblFIELDTAB = Func.Tables("FIELDTAB")
    If Func.Call = False Then
         MsgBox Func.Exception
         Exit Sub
    Else
        Application.ScreenUpdating = False
            For intCol = 1 To tblFIELDTAB.ColumnCount
                ThisWorkbook.Sheets("TEST").Cells(1, intCol).Value = tblFIELDTAB.ColumnName(intCol)
            Next
            If tblFIELDTAB.RowCount > 0 Then
                For intRow = 1 To tblFIELDTAB.RowCount
                    For intCol = 1 To tblFIELDTAB.ColumnCount
                        ThisWorkbook.Sheets("TEST").Cells((intRow + 1), intCol).Value = tblFIELDTAB(intRow, intCol)
                    Next
                Next
                ThisWorkbook.Sheets("TEST").Activate
            End If
            Columns.AutoFit
        Application.ScreenUpdating = True
    End If
    '* clear tblFIELDTAB                                                      *
    Do Until tblFIELDTAB.RowCount = 0
         Call tblFIELDTAB.Rows.Remove(1)
    Loop
    Set sapConn = Nothing
    Set Func = Nothing
    Set tblFIELDTAB = Nothing
    End Sub

  • Unable to change RFC destination in IT Performance reporting wizard

    Hi Experts,
    I am setting up IT Performance Reporting in my Solman EHP1 system. In the first page of the PErformance reporting wizard, it asked me for RFC destination from BI to Solman(1st field) and Solman to BI (2nd field). I initially entered an existing RFC destination that we are already using in a separate application that has a user with very-limited authorization. Now, I am trying to change the RFC destination by running the same "Configure IT Performance Reporting" wizard but both fields are already GREYED out.
    I tried deleting the RFC destination previously defined in an attempt to reenable the fields but only the 2nd field was enabled. When I try to continue the setup, it results into a Shortdump because it is still looking for the initially defined RFC dest which is defined in the 1st field that cannot be edited.
    SAP has not yet provided us with a solution.Your help is greatly appreciated.
    Thank you very much.

    You canprovide the RFC destination in DOE administration portal. Goto Configurations link and search for "BACKEND DESTINATION" parameter in "BACKEND CONFIGURATION" link. Here you can provide RFC destination at SWCV level or at Data object level.
    After deleting RFC destination in SM59, it will never take you to backend system.

  • Creation of RFC Destination problem

    Hi Experts,
    I need to establish an RFC communication between TREX7.0 server running on windows 2003 server and the SAPR/3 4.7 EE server running on windows2000.
    server. Initially i used TREXAdminTool to create RFC Destination, i was unable to create successfully
    Then i used SAPR/3 server from  TCODE: SM59, here also am facing the same problem, what are the values i have to give  for
    1. RFC Destination, 2. Program id 3. Gateway Host and Gateway Service.
    PLZ  guide me step by step procedure with some example values to create RFC Destination to TREX Server successfully using TREXAdminTool or from SAPR/3 server---SM59
    ADV Thanks
    Regds
    phanikumar

    Hi,
    Till now i didn't install explicitly any SAP Gateway on TREX server.
    I installed TREX server along with SAP Netweaver WEB AS java.
    Shall i need to install any SAP Gateway to configure RFC Destination?
    If so can you give me the procedure how to install explicitly SAP gateway?
    Regds
    Phanikumar

  • RFC Destination - Unicode / non - Unicode behavior

    Hi All,
    In our current production system the RFC destination from R3 to Xi is non-unicode.We have currently 300 Interfaces running using this RFC destination in production.
    In few upcoming requirements for some 15 Interfaces some special characters will come from R3 to Xi system.In this case we need a unicode RFC Destination.
    I have a query here , can i go ahead and change the existing RFC destination to Unicode or is it suggestible to create a new RFC destination only for these 15 Interfaces?
    Need expert advice on this?
    <<Text removed>>
    Regards,
    RK
    Edited by: Matt on Oct 5, 2011 9:38 AM

    Hello,
    The Non-Unicode Single code page systems are supported by SAP for older applications for historical reasons - unicode was not available when they were released. These systems are restricted to only processing characters from their specific code page. This means their can be restrictions if they need to support language combinations that span multiple code pages - basically it is not possible. In addition some languages are not fully available at all for single code page systems like Thai. In addition the Euro symbol is not available.
    Unicode is the future for all applications - SAP or otherwise. The significance at the moment is where customers who needs to convert to unicode to support additional business requirements like additional languages. Converting a system, although a simple process is not a trivial process in terms of time and resources.
    So u can go ahead and change the existing RFC destination to Unicode .it will not create any prob. for other interfaces which are using non unicode setting.
    Regards
    Monica

  • RFC destination for VMC (Virtual Machine Container)

    Hi ,
    Just loaded the CRM 70 system (customers, materials, contacts, ... ) and the KB from the back-office (ECC 6.0).
    Calling the IPC via transaction COMMPR01 for a configurable material we have the following call in error :
    FUNCTION ipc_get_knowledgebase.
    CALL FUNCTION 'CFG_API_GET_KNOWLEDGEBASE' DESTINATION gv_vmc_dest
    The RFC destination 'gv_vmc_dest' is empty . How to setup the RFC destination for VMC and the configuration so SAP know the RFC destination is the one to use for the VMC.
    Thank you

    Klaus ,
    Thank you , yes VMC is on the same CRM7.0 server , I do get the following short-dump .
    Short text
        "Found no handler for remote function module CFG_API_GET_KNOWLEDGEBASE"
    What happened?
        Error in the ABAP Application Program
        The current ABAP program "SAPLIPC_API_CFG_COMMAND" had to be terminated because
         it has
        come across a statement that unfortunately cannot be executed.
        The error occurred during an RFC call to another system.
        In the target system, a short dump has been written as well.
        More detailed information on the error cause can be found there.
    Error analysis
        An error occurred when executing a REMOTE FUNCTION CALL.
        It was logged under the name "RFC_EXTERNAL_ABORT"
        on the called page.
    Trigger Location of Runtime Error
        Program                                 SAPLIPC_API_CFG_COMMAND
        Include                                 LIPC_API_CFG_COMMANDU07
        Row                                     19
        Module type                             (FUNCTION)
        Module Name                             IPC_GET_KNOWLEDGEBASE

Maybe you are looking for

  • How to get certification for MY Adapter.

    Hi guys,   Now i am working on Adapter Development.Can anyone tell me what are the conditions i should satisfy to get my Adapter certified by SAP. Regards, Gowtham K.

  • Speeding up of spatial Queries - SDO_Intersection

    HI, I'm running a basic query - calculating the area of spatial intersection sbetween two polygonal datasets: select  s.Designation, SUM ( sdo_geom.sdo_area( sdo_geom.sdo_intersection (s.geoloc, m.geoloc, 0.0005), *0.0005, 'unit = HECTARE')) total_ov

  • Create a document link iview

    Hello, Can anybody please tell me about how to create a km document 'link' iview ? I mean i want to create a document iview that can be link to a url, but this is not a url iview. In this case, i will create a document iview that show a .jpg file, an

  • BC4J Classes and API Document

    Folks, We need to make a quick decision whether we will build our application using BC4J as our J2EE framework. I have gone through some documents from Oracle web site and Jdeveloper's tutorial and BC4J samples. But I fail to see any published class

  • Error  Import process

    I've a problem with import processes of mapping . When I want to import a old mapping in another repository, I need before delete it . When I delete it I lost the audit information of this mapping for each execution. Is possible import a old mapping