RFC error with SAPOSS (test connection)

Hello All,
RFC error with SAPOSS Test connection
Language:EN
Client      :001
User        :OSS_RFC
Target system settings:
Balace load = Yes
RFC error is below:
                          Connection test SAPOSS
Connection type:    R/3 connection
Connection error        Error opening an RFC connection.
ERROR                  partner not reached (host 209.94.207.139, service sapdp99)
LOCATION              SAP-Server orionbw_QBW_00 on host orionbw2 (wp 0)
DETAIL                   NiPConnect
CALL                      connect
COMPONENT         NI (network interface)
COUNTER               9
ERROR TEXT           Network is unreachable
ERROR NUMBER    101
MODULE                 nixxi.cpp
LINE                        8628
RETURN CODE       -10
SUBRC                   0
RELEASE               640
TIME                      Wed Jul 30 10:06:05 2008
VERSION               37
Please let me know how to proceed.
Thanks in advance.
Best Regards,
Pratyusha

Hi Markus,
I went to OSS1 transaction  Menu ---> Parameter --> Settings -
> SAP Routers at Customer Site ---> SAP Router 1
i have Added Name and IP address and instance No.
Now its throwing another error:
=============================================
ERROR                   rgcwebsrv: route permission denied (orionbw2.rgc.corp to 147.204.2.5,
LOCATION                SAProuter 37.11 on rgcwebsrv
COMPONENT            NI (network interface)
COUNTER                 5580
MODULE
LINE
RETURN CODE          -94
SUBRC                       0
RELEASE                   640
TIME                           Wed Jul 30 10:41:28 2008
VERSION                     37
=============================================
We are struck here.
Thanks in advance
Best Regards,
Pratyusha

Similar Messages

  • MAM RFC Error with Order and Notification SyncBo's

    Hi everyone, can you please advise on a problem I'm having when downloading 2-WAY SYNCBO MAM objects.
    I am able to download all syncbo's to my client with my username.  This includes Orders and Notifications.
    But.....whenever I use a different username only some of the SyncBO's come over.  I am missing MAM25_001 and MAM25_010 data.  Here is what I have done so far:
    -  Ensured username had exactly the same SAP security profile as I do, including the MI authorization objects.
    -  Ensured username was configured the same in the IMG.
    -  Re-generated and re-replicated my SyncBo's.
    -  Checked table MEREP_10100.  It showed no Order or Notification data.
    It does not make sense why everything works for me, but not for other usernames on my network.
    Here is the RFC error I get from the Middleware using MEREP_MON:
    RFC system Error:
    Z_MEREP_GEN_S01_____MAM25_010 has finished for run number 0000019624 and runtime counter 17.
    Please help.  Thanks.

    Hi Alex,
    Could you please reply the SP levels of the MI Client, MI server and MAM application?
    Also is your client device a PDA?
    You could try out few things ( not sure whether they will help)
    1. Sync several times (may 6 times) for the other users.
    2. Remove the MAM application for the one of the other usernames from the webconsole(which is not able get the data) and reassign it.
    3. Try the username on some other device.
    All the best!!!
    Regards,
    Rahul

  • HELP!error with 8i IIOP connection

    Using Jdev. 3.1 I get the following error while in the connection manager:
    "An error occurred while connecting to the database:
    org.omg.CORBA.CORBA_OBJECT_NOT_EXIST[completed=NO]"
    The database is Oracle 8i 8.1.6
    What does this mean and what do I need to do to resolve this.
    Thanks...
    Frank
    null

    If you can't connect with session shell, drop me a line and I'll send you a white paper that discusses setting up IIOP with Oracle 8i

  • SAPOSS  Test connection

    Dear All,
    in SM59 : RFC  Connection Test  : for SAPOSS throws an
    Return Code  -12
    Please guide to resolve the issue.
    Regards
    SNB.

    Hi,
    SAPOSS is configured automatically on the basis of data in OSS1. However, if SAPOSS isn´t working, please make sure that the entries for 'Technical settings' in OSS1 are correct. Refer to Notes 33135 and 30289 for more information on OSS1. To ensure SAPOSS is maintained with 'load distribution' set to 'yes', please follow note 766505. SAPNET_RFC and SAPNET_RTCC are copies of SAPOSS. They get created automatically when the tools SDCC (SAPNET_RFC) and RTCCTOOL (SAPNET_RTCC) connect to OSS the first time. They get created with 'Loadbalancing' switched on. This makes the entry in the field 'Target Host' appear very short - please note that the full string as described below can only be maintained if 'Loadbalancing' is set to 'No'.  Please note that after an update of SAPOSS via TA OSS1 the client may change to 000 - please update this manually to 001. Also, after an update of SAPOSS via TA OSS1 SAPNET_RFC and SAPNET_RTCC do NOT get updated automatically. The easiest way to ensure they are updated correctly is to delete both destinations, and then start a connection to OSS from the tools ( SAPNET_RFC: SDCC -> Maintenance -> Refresh -> Service Overview. SAPNET_RTCC: SE38 -> RTCCTOOL) Often ( but not always - systems with 2 saprouters can be different) the parameters of a working SAPOSS or SAPNET_RFC destination (where Load balancing is set to 'No' ) are set up like this:
    Target host: /H/X1/S/sapdp99/H/X2/S/sapdp99/H/oss001 with
    X1 = customer saprouter IP address
    X2 = IP address of sapservX    sapserv1 (194.117.106.129) Internet VPN connection
             sapserv2 (194.39.131.34)   Internet SNC connection
             sapserv3 (147.204.2.5)     for customers connected to Germany.
             sapserv4 (204.79.199.2)    for customers in Americas.
             sapserv5 (194.39.138.2)    for customers connected to Japan.
             sapserv6 (194.39.139.16)   for Australia and New Zealand customers.
             sapserv7 (194.39.134.35)   for Asia customers.
    SAPOSS and SAPNET_RFC
          System number = 01
          Client = 001
          User = OSS_RFC
          Password = CPIC
    SAPNET_RTCC
          Client = 001
          User = ST14_RTCC
          Password gets set automatically when the destination is created. In case of problems with the password please delete SAPNET_RTCC and recreate it.
    Hope this should help you.
    Regards
    Tanuj

  • ICweb - RFC error with CRM_FICA_CUST_READ

    Experts,
    We just refreshed our DEV systems:
    CRM2007 sp6
    ECC60 ehp3 sp5
    I'm trying to connect the middle-ware and run ICweb as I usually do.  I've double/triple checked all my RFCs, post copy steps, BDLS, etc on both ends.
    But the FM CRM_FICA_CUST_READ, when executed on the CRM system does not return the proper back-end (ECC) log sys name and RFC dest.
    I double-check tcode  sale --> communications --> determine RFC destinations for method calls (BD97).
    it is correct and has the right RFC which is completely trusted by back-end.  And it works.
    But still, when I execute FM CRM_FICA_CUST_READ I get:
    System settings missing for RFC access to FI-CA system
    The error returned is ICRM_IC_APPL_UI_FICA 208System settings missing for RFC access to FI-CA system
    I guess we'll start over with the system copy/refresh but if you have any hints about other steps to deal with this, please post.
    I also read note 746475  Financial Customer Care - Collections Management
    This is what led me to test that FM.
    Thanks
    NICK

    Hey Denis,
    Basically, all the subscriptions were listed: Business agreements, bus partner relationships, business partners (bupamain), and business transactions.  But they were not assigned to the "site"..aka our ECC system.  And when I clicked on each subscription, it gave me an error.
    So clearly something got messed up when I did my client copy or maybe some transport.  At any rate, we just deleted them and re-added.  then we were good.
    --NICK

  • SAPGui 720 and RRMX - RFC Error with a Message server

    I am testing SAPGui 7.20 before installing it on all workstations. I found an error RFC_ERROR_COMMUNICATION in the following situation.
    Client side:
    WIndows XP SP3
    Office 2003
    SAPGui 720 + patch 2 (gui720_2-10007878.exe)
    BI 7.0 ADDON FOR SAP GUI 7.20 (bi720sp02_200-20006596.exe)
    BW 3.5 ADDON FOR SAP GUI 7.20 (bw350gui720_2-20006857.exe)
    Server side:
    Installed the following notes: 1471630, 1499568, 1477686, 1473879
    I connect to P1B (Production systrem) with my login/password. Then I launch RRMX and the following error appears:
    RFC_ERROR_COMMUNICATION
    SAP_CMINIT3 : rc=20 > Connect to SAP gateway failed
    Connect_PM GWHOST=tosatti, GWSERV=sapgw50, SYSNR=50
    LOCATION CPIC (TCP/IP) on local host
    ERROR hostname 'tosatti' unknown
    TIME Fri Sep 10 10:37:09 2010
    RELEASE 720
    COMPONENT NI (network interface)
    VERSION 40
    RC -2
    MODULE nixxhl.cpp
    LINE 183
    DETAIL NiHLGetNodeAddr: hostname cached as unknown
    COUNTER 2
    This error happens only on Production system. On Development and Quality systems it is ok. The difference between these systems is that Production has a message server (po1bwsc.sapmi.telecomitalia.local) and a Group server defined
    (PROD_P1B that leads to 4 application servers).
    If I force the application server to logon to po1bwsc.sapmi.telecomitalia.local everything works well, but using the
    group server I get the error above.
    Furthermore I found out that:
    if I add the IP address of the GWHOST (tosatti in this case, but I have also donald and alexey) in c:\windows\system32\drivers\etc\hosts file, everything works fine.
    Please notice that with SAPGui 640 there is not this problem, even without adding the above IP addresses to etc\hosts file.
    How can I avoid this problem?
    Thanks
    Roberto Pezzano

    What parameter did yiou have to change for this?
    We are experiencing same issue.
    Thanks in advance!

  • Error with opening a connection to a url (for cgi use)

    i still am having trouble using a cgi executable on my server, but i cant seem to narrow down what my problem is.
    i followed the following tutorial, but am still getting errors.
    http://java.sun.com/docs/books/tutorial/networking/urls/readingWriting.html
                  //  first of all, am I doing this right? all the examples leave out the '.cgi' at the end, why?
                  //does it matter? i tried both ways, i even tried with the ?var1=something stuff at the end. nope.
                  url = new URL("http://www.somewhere.com/" + "write.cgi");
                  urlConnection = url.openConnection();
                  urlConnection.setDoOutput(true);
                  // here is where I get an IOException error ----  error.getCause() yields an output of null
                  PrintWriter out = new PrintWriter(urlConnection.getOutputStream());
                  // i also am not sure how sending to the cgi works. my cgi file was written to parse a string
                  // such as this: "http://www.somewhere.com/fileio.cgi?field1=something&field2=something+else"
                  out.println("whatever i need to send it")
                  out.close();is it possible i'm getting this error because my cgi file isnt set up right? i am confident that it is ok, but i dont know for sure, nor do i know how to test it. typing in
    /fileio.cgi?field1=something&field2=something+else into the working directory of my webpage yields an error that says something like that page isnt readable. i had hoped i could test the cgi this way...is there another way?
    thanks!

    Using the URLConnection output stream doesn't append attributes to the url. If you want to send parameters on the url use
    url = new URL("http://www.somewhere.com/write.cgi?field1=something&field2=something+else");

  • Error with web services connection to B1 DI API

    We are attempting to utilize the web services connection to SAP Business One and are running into difficulty.  Below are the particulars:
    -   We are attempting to make a web services connection to B1 using PHP on Linux.
    -   We are able to establish a session, but not able to make a successful web services request.
    -   The attempted action is to add a Business Partner
    -   Error we are receiving:
    SoapFault exception: Not Found in /var/www/test.php:83 Stack trace: #0 : SoapClient->__doRequest('__call('Add', Array) #2 /var/www/test.php(83): SoapClient->Add(Array) #3
    -         We are also able make a successful web services request to the same B1 server using ASP from Windows.
    -         Once we establish a session through PHP / Linux, the DI Server will not respond to either PHP or ASP on Windows
    Any advice or suggestions would be appreciated.

    Russell,
    Since you are getting a "SoapFault Exception", you must be trying to use SOAP messaging.  The DI API does not understand SOAP messages.  You would need to use the DI Server (SDK Help has information on DI Server) for SOAP based messaging and in turn you may also want to look at the Business One Web Services (B1WS) tool that s located in the Tools section of the SAP Business One main page here on SDN.
    HTH,
    Eddy

  • Error with Discoverer ADministrator connection

    Hello:
    I´m working with IAS and Discoverer 10g R2.(the discoverer installation is in another Server)
    My problem is that i can't connect to Database with Discoverer Administrator because i have the error ORA.12170 of timeout.
    But if try to connect me for SQL*PLUS i dont have any problem.
    If i try with tnsping i get the same error message.
    C:\ora10_bi\opmn\bin>tnsping BDINFRA.aplicativo.com
    TNS Ping Utility for 32-bit Windows: Version 10.1.0.3.0 - Production on 29-AGO-2
    005 17:53:34
    Copyright (c) 1997, 2003, Oracle. All rights reserved.
    Archivos de parßmetros utilizados:
    C:\ora10_bitools\network\admin\sqlnet.ora
    Adaptador EZCONNECT utilizado para resolver el alias
    Attempting to contact (DESCRIPTION=(CONNECT_DATA=(SERVICE_NAME=BDINFRA.aplicativ
    o.com))(ADDRESS=(PROTOCOL=TCP)(HOST=216.187.103.170)(PORT=1521)))
    TNS-12535: TNS:timeout de la operacion
    My host don´t have the ip 216.187.103.170 and i don´t understan why the connection try to connect with the adpater EZCONNECT define in my sqlnet file.
    My tnsnames are:
    discoverer installation.
    BDINFRA =
    (DESCRIPTION =
    (ADDRESS = (PROTOCOL = TCP)(HOST = aplicativo)(PORT = 1521))
    (CONNECT_DATA =
    (SERVER = DEDICATED)
    (SERVICE_NAME = bdinfra.aplicativo.com)
    EXTPROC_CONNECTION_DATA =
    (DESCRIPTION =
    (ADDRESS_LIST =
    (ADDRESS = (PROTOCOL = TCP)(HOST = HOSTNAME)(PORT = 1521))
    (CONNECT_DATA =
    (SERVICE_NAME = PLSExtProc)
    infraestructure instalation
    BDINFRA =
    (DESCRIPTION =
    (ADDRESS = (PROTOCOL = TCP)(HOST = aplicativo)(PORT = 1521))
    (CONNECT_DATA =
    (SERVER = DEDICATED)
    (SERVICE_NAME = bdinfra.aplicativo.com)
    EXTPROC_CONNECTION_DATA =
    (DESCRIPTION =
    (ADDRESS_LIST =
    (ADDRESS = (PROTOCOL = TCP)(HOST = HOSTNAME)(PORT = 1521))
    (CONNECT_DATA =
    (SERVICE_NAME = PLSExtProc)
    How can i solve this problem?
    Thank you.

    Check the firewall settings on your server. Make sure that port 1521 is not blocked.

  • Mush/Audio Errors with MacMini (2012) connected via Firewire with Motu 828mk3

    Hi,
    just bought a Mac Mini (actual model) and wanted to connect my Motu 828 mk3 via Firewire for audio recording. BUT, via FW there are audio errors/mush (sounds like electrical mush) in all the audio outputs. Via USB its all o.k. ! The Motu works fine with an 2008 MacBook Pro on Firewire!
    Has anyone the same problem with audio interfaces on macs using firewire, especially on the actual Mac mini? Is it a problem of the Mac (Mini) Firewire port?
    The Mac Mini has installed the latest Motu drivers and the latest version of OS X Lion. The problem exists in all audio applications (Cubase, AudioDesk, Wavelab, even iTunes).
    Thanks for your help/answers and best regards.

    The problem stems from the Mac (in my case Mac Mini Server 2011).
    Apparently, as I read in various forums looking for Mac and Logic, the new models of Mac Mini (2011) have lowered the voltage Firewire.
    I have the same problem with my new Track-16.
    I can only work fine with USB connection.
    Either we change the computer model, or users of Mac Mini (2011) we can forget a Firewire connection powerful and efficient.
    Only remains for me try to connect to an external HD Motu firewire 800 which is connected to the Mac Mini previously. I guess the external HD, to be powered via AC, will have enough voltage to the Motu.
    Best regards.

  • [28035] Error with a GPRS connection

    Hi to all,
    We always have this problem using GPRS connection calling the sync web service with HTTPS protocol whereas HTTP is always functionning (on both mode : GPRS/wired).
    System.Data.SqlServerCe.SqlCeError: Internal error: HTTP header information is either corrupted or missing in the transport message. It could be a network transmission error or an IIS problem.<u5:p></u5:p>
    \tError Code =28035<u5:p></u5:p>
    \tHResult = -2147012746
    Technical informations:
    PDA on Windows Mobile 6.5
    SQL CE 3.5 SP2
    Device : Motorola MC 65/55
    SQL Server 2008 R2
    We believe that the reverse proxy is involved because when the PDA is using wired connection, no reverse proxy is used because we are already in the company network. Indeed:
    GPRS mode : PDA <-> firewall <-> RP <-> Web servers <-> SQL Servers
    Wired mode : PDA <-> Web server <-> SQL Servers
    Didier.

    Nothing concrete, other than what bing can find:
    http://dbaspot.com/ms-sqlserver/216339-error-28035-header-information-either-corrupted-only-gprs-internet-works-why.html
    Please mark as answer, if this was it. Visit my SQL Server Compact blog http://erikej.blogspot.com

  • HDCP Error with HDMI-VGA connections

    We have been using Apple TV 3 Software Version 7.0.2(6915) for connecting the Apple TV to classroom projectors that have a VGA port in. This was working perfectly till last week, and it seems a new software update was pushed to the Apple TV device now we get "This Content Requires HDCP for playback". Tried multiple different options of soft and hard reboots, resets and restarts nothing helps. Connecting the same Apple TV using HDMI-HDMI cable works fine. We are using Kanex HDMI-VGA adapter. If someone has the same issue please write back since there have 26 Apple TVs in the school and is being actively used by instructors to project their work to the class.

    ravijn wrote:
    We have been using Apple TV 3 Software Version 7.0.2(6915) for connecting the Apple TV to classroom projectors that have a VGA port in. This was working perfectly till last week, and it seems a new software update was pushed to the Apple TV device now we get "This Content Requires HDCP for playback".
    As far as I know, 7.0.2(6915) is the latest software version & nothing new has been pushed out by Apple since its release months ago.
    You problem is most likely exactly what the error message indicates: the content (for example commercial movies from a streaming service or an iTunes library) you are trying play on the ATV is protected by the HDCP encryption standard, so unless the Kanex adaptor supports HDCP internally, the ATV will not output the protected content to it.
    I looked on the Kanex website to see if they claim the ATV Pro adaptor supports HDCP but nothing there says if it does or doesn't. Also, one of the U.S. Apple Store questions about the device has conflicting answers for that, so I suggest you contact Kanex directly for a more definitive answer & perhaps some help with the issue.
    Failing that, you could try your setup with some content you know is not protected by HDCP (like a home movie in an iTunes library). If that works, then the problem almost certainly is that the Kanex doesn't support HDCP & you will not be able to use it with any content so protected.

  • Error with iTunes when connecting for first time.

    Here is the error that I get when I connect my phone to my computer:
    The software required for iPhone is not installed. Run the iTunes installer to remove iTunes. then install iTunes again.
    I have the latest version on iTunes installed (7.3). I have tried removing itunes and reinstalling 4 or 5 times. Evan restarted my computer few times too. I'm running Vista so not sure if that's the problem.

    Hi Bigrash,
    Close iTunes, and disconnect your iPhone from your computer.
    Go to "Control Panel", and go into "Programs".
    Select "Installed Programs".
    Here, find "Apple Mobile Device Support" from the list, and click on it. From the "File" menu, select "Change/Remove", and then click "Remove".
    After that application has been fully uninstalled, go to this page, to download another copy of the iTunesSetup.exe installer:
    Download iTunes - 7.3.0.54
    After you've downloaded the iTunes installation pack again, launch iTunes, and connect your iPhone.
    Do you still get that same error message, or not?
    -Kylene

  • 6230i wierd error with phone when connecting to bl...

    I have had it working on my old computer, and now when i am trying to get it to work on this new computer, i get this error...
    http://img123.imageshack.us/img123/8444/problem15l​v.jpg
    .....Message Edited by titch2349 on 13-Feb-2006
    06:41 PM

    The new PC Suite will want the older version uninstalled first.
    I suggest doing a backup of your phone contents.
    Then backup your PC (if running XP set up a system restore point).
    Copy the existing PC Suite folder (and contents) into a zip file - you need to stop PC Suite from loading automatically to make sure you can copy all the files.
    Then install the new PC Suite.
    If the PC copies of the images etc are no longer present then copy them back from the zip file.
    But....
    Before you do all that - make sure your PC Bluetooth drivers and firmware are up to date. The 6230i only uses 'Component' key pairing whereas most existing (older) equipment uses 'Unit' key pairing.
    Also the Microsoft XP SP2 Bluetooth is Microsofts version of Bluetooth which is not entirely compatible with everyone elses Bluetooth.
    The latest Belkin Bluetooth firmware and software does work with the 6230i.
    goodluck
    SteveMessage Edited by stevemess on 14-Feb-2006
    10:13 AM
    Tech. Project Manager
    Reuters

  • Strange errors with m2 blades connected over fiber channel to a 3par san

    We are seeing numerous errors in the logs saying
    Mar  9 10:00:19 **** kernel: rport-2:0-238: blocked FC remote port time out: removing rport
    These hosts have 4 virtual hbas connected to a 3par san. we are seeing less than optimal io performance.

    Please explain your environment physical connectivity.
    Ram

Maybe you are looking for

  • At new command not working

    Hi all,    I pasted my sample code below. In this i have used "At new event" this command is not working in my code, the values are redundant, How to rectify this problem. Pls help me. Thanks in advance. Tables : RBKP,          RSEG. Data : Begin of

  • A plea to Adobe

    Our company started using Bridge and Version Cue about a month ago and it has solved all of the problems we used to have with keeping everybody up-to-date... when it works. PLEASE Adobe, delete all of your Bridge and Version Cue code and start over f

  • How do I get Vista to go back to the Windows' Vista generic driver after an Extigy upgrade fiasco

    Hello all. First, I'm glad to have the opportunity to be a part of this group. I didn't know it even existed, but here I am...so, let me know what you think. I am a new Windows Vista Ultimate OS owner, and thus far, I'm absolutely thrilled with the a

  • Value  ZERO in BW

    Hi All, Sales Order and Delivery has been created with one line item and  schedule line in R/3. This record has been loaded into BW (DataSource 2LIS_12_VCSCL) Eg:  DelNumb SalesOrd  Lineitem Schedule Line Delqty           1234                   123  

  • Receiving Day / Shipping Point

    Hi Experts! When delivering e.g. to Spain from a German shipping point there is a calendar assigned on customer site that has no holiday at all combined with a fixed receiving day "Friday". The German calendar is assigned to the shipping point. Becau