RFC & Logical Name difference-connectivity

Hi
I have by mistake given different name of logical & RFC systems in CRM & ECC. Like if name of logical & RFC systems in CRM is X, then in ECC I have named them as Y.
Now I have downloaded BP & Products without any problem. My question is :
In future can it cause, problem in any way. I have seen various documents but no where it is mentioned that they have to be same in the two systems.
Thanx in advance.
Cheers
Hits

Hi Piyush
Thanx for your reply. In my scenario name of CRM system is different in ECC & CRM. In CRM I have defined RFC & Logical CRM system name as X, whereas in ECC it is Y.
When I goto SMWP for adapter status information, in ECC table CRMRFCPAR it is expecting value X. The status of adapter status is yellow. Till now I have downloaded product & BP, no problem has occured.
Cheers
Hits

Similar Messages

  • Source System Logical Name change

    Hello,
    We are refreshing our R3Qas system with a copy of our R3Prd system.  As part of this task our R3Qas logical name is changing from QASC230 to QASC200.
    I am at the point in the refresh where I am beginning tasks on the existing BWQas system. 
    I Right Click on the source system representing the R3Qas system "QAS client 230" technical name: QASC230.  I choose 'Restore'  I then provide the logon information but the system it jumps to is the Old R3Qas not the new R3Qas.
    I know that it is jumping based on the RFC, So I assume I can change that RFC to jump to the new system, what do you think?  Also what about the Source System name an technical name, will it always be QAS Client 230 and QASC230 or can that be changed to reflect the new name of QASC200?
    Thanks for your advice and assistance!
    Nick

    Since the BWQ system was already an existing system that was attached to the previous R3Q system, this task was essentially busy work.
    The change that occured was that the existing R3Q system (Physical Name: QAS01 Logical Name: R3QASC230) was being replaced with a new R3Q system (A copy of Production was used) (Physical Name: QAS02 Logical Name: R3QASC200).
    The actions that I needed to take to connect BWQ to the new R3Q follow:
    1. On QAS02 visit TX SE37. and run RSAP_BIW_DISCONNECT, Choose 'Single Test'.  For I_BIW_LOGSYS: I provided BWP001 which corresponds to the logical name of our Production BW system. For I_OLTP_LOGSYS: I provided R3PRDC200 which corresponds to the logical name of the QAS02 system (this system).  I then Click 'Execute' and 10 seconds later this step is done.
    2. On QAS02 visit TX: BDLS.  For the 'Old Logical System Name' provide BWP001.  For the 'New Logical System Name' provide BWQ001.  Ensure the 1st radio button is selected, and deselect all checkboxes.  From the Program menu choose to 'Execute' in background (it took about 45 minutes). Confirm the 'Mapping System Name'.
    3. Again on QAS02 visit TX: BDLS.  For the 'Old Logical System Name' provide R3PRDC200.  For the 'New Logical System Name' provide R3QASC200.  Ensure the 1st radio button is selected, and deselect all checkboxes.  From the Program menu choose to 'Execute' in background (BASIS already did this step so a message appeared to that effect)
    4. On the BWQ box visit TX: BDLS.  For the 'Old Logical System Name' provide R3QASC230.  For the 'New Logical System Name' provide R3QASC200.  Ensure the 1st radio button is selected, and deselect all checkboxes.  From the Program menu choose to 'Execute' in background (it took about 45 minutes). Confirm the at the prompt and run.
    5. On BWQ create new RFC's based on the old ones to point at the new QAS02 system.  Modify the old ones with an X in the 'Target Host' so they do not function.
    6. Open up the BWQ client in SCC4.  (or perhaps try SM30 to modify the table in the next step)
    7. On BWQ visit TX: SE16.  Tablename: RSLOGSYSDEST.  Change the 'Old' reference to the QAS box to the 'New' information.  (ie: R3QASC230 became R3QASC200).
    8. On BWQ visit TX: WE20.  Expand 'Partner Type LS', Select 'R3QASC200', click the classification tabe, change the 'Partn.Status' from I to 'A' and save.
    9. On BWQ right click on the R3 Source system and choose 'Restore' Provide the passwords that are required.  When prompted to logon to the remote system use an ADMIN (BASIS) level Account.  Click 'Continue' when you get the 'User exists...' prompt.  Click 'Only Activate' when prompted.  you will then get a termination message regarding the port description.
    10. On BWQ Back at WE20: Expand 'Partner Type LS', Select R3QASC200, double click on RSRQST.  Under 'Outbound Options' click the drop down for 'Reciever port'  Select the 'new' correct system and 'Save'.
    11. On BWQ right click on the R3 Source system and choose 'Restore' Provide the passwords that are required.  When prompted to logon to the remote system use an ADMIN (BASIS) level Account.  Click 'Continue' when you get the 'User exists...' prompt.  You will get a prompt to Use or Check, choose 'Use'.  When prompted about 'Connection cannot be used' click 'Delete'. Logon again as ADMIN account, Click 'Continue' when you get the 'User exists...' prompt. Click 'Replicate as well' when prompted.  you will then get a termination message regarding the port description.
    You should be all set now!
    Nick

  • BW Development Logical Name Change Impact

    Hi,
    what is going to be the impact on our BW system (extraction / modelling / reporting) if we change the BW logical name.
    Example:- BW Development current logical name is BWCL005
    New Name change to BW005.
    Can you please help
    Regards
    Rajiv

    some of the impacts i can comment on are as above.
    1. wherever u have hardcoded logical name, there u have to modify to new name.
    2. regarding the RFC connection with other servers make sure there is there is 2 way communication with the every server, this is basically a BASIS task and needs to confirm with great care.
    hope it helps.
    kindly assign the points if it helps.

  • Logical Name and Physical Name of OWB Objects?

    Hi,
    I am using OWB 10G R1. Version: 10.0.1.0.4
    I would like to know, is there any table/script to get list of physical name and logical name of OWB objects (mapping / process flow).
    Any help would be appreciated greatly.
    Thank you,
    Regards,
    Gowtham Sen.

    Hi,
    I only have a skript for OWB 10.2.0.3, maybe it will work with 10gR1 as well:
    SELECT object_type,
           object_name,
           logical_name,
           object_path
      FROM (SELECT owm_view_utilities.classified_obj_type2(f.elementid, f.classname) AS object_type,
                   f.NAME AS object_name,
                   f.logicalname as logical_name,
                   sys_connect_by_path(f.NAME, '/') as object_path
              FROM firstclassobject_v f
             WHERE 1 = 1
            CONNECT BY f.owningfolder = PRIOR f.elementid
             START WITH f.NAME = 'MY_PROJECT')
    WHERE object_type IN ('Process', 'TransformMap')
    ORDER BY object_type,
              object_name
    ;Just replace 'MY_PROJECT' with your project name.
    Regards,
    Carsten.

  • RFC as type of connection in transaction sm04 of Database server

    Hello I wander what means RFC as type of connection in transaction sm04 of Database server.
    Does it mean an user logged on applicaton server is displayed on database server as RFC?

    Hi Jan
    User login to SAP may be possible with either GUI or RFC. GUI implies to direct logon to SAP though the SAP GUI. This is characterised by the user name.
    The other way is RFC which implies to remote access to the system. This is usually characterised by IP address or the domain address .
    I hope this helps
    Regards
    Chen

  • System NSP client 001 has no logical name!

    HI all.Im install SapNetWeaverSneakPreviewABAP.
    -client copy (txn SCC4) into say 001
    -log on to 001 with **** and pass
    transaction SCCL source client 000 and target client 001.
    -now run transaction RSA1 for initial bw setup
    AND SAP output System NSP client 001 has no logical name!
    And two button - create and assign...
    Please howto info

    hi,
    have you assigned client 001 to logical system ?
    spro->bus inf warehouse->link to other systems->general connection settings->assign client to logical system.
    take a look
    http://help.sap.com/bp_biv235/BI_EN/BBLibrary/documentation/B84_BB_ConfigGuide_EN_DE.doc
    hope this helps.

  • Report issue , logical name of the system has been changed

    Hi
    Recently our system has been upgraded to ECC5.0. In a particular report  while drilling down we get  error. The error says the original doc can not be shown as it belongs to logical system ( DRH-123) . Now we know that this logical name of the system was in old box . The new logical name is DRH-100 . We are saying it's a basis issue and the basis team is saying it's FICO issue.Has any body encountered this type of problem. ? In my report  i have never mentioned logical name of the system.Hence unable to understand it. But so far what I have understood , that the each box  has been partioned and given a system name which is called logical name.Now that logical name they have changed in new box.My initial response was change the logical name but basis says that is a big task and more over it has been a while when they changed it.
    Gurus, Kindly shed some light on this mess.
    Thanks in advance
    Satya

    Which report are you pulling out? T-code?
    This link has some that may help you:
    www.scribd.com/doc/24447/SAP-R3-IDoc-Cookbook-for-EDI-and-Interfaces-by-Axel-Angeli
    Do CTRL+F to find Logical Systems
    If the link doesnt work use the following keywords and google it, shoose second result: EDI IDOCS interface axel angeli sap
    You may also want to get in touch with the person who was involved in developing LS. Talk with your ABAPer, they normally have an idea about these things (well atleast my ABAPer knows!)
    Message was edited by:
            Vj

  • Physical path and Logical name in File adapter

    Hi All-
    I am using a file adapter, in which i need to specify the physical path or logical path.
    In dev environment my file adapter's input path is /c01/interface/dev/input, but in my test environment it is /u01/interface/test/input.
    So everytime I have to change the path and deploy it in two different environment.
    I am using unix environment, is there any way i can use some environmental variable $INPUT_DIR and use it in logical name so that in logical name i can use as $INPUT_DIR/input, where in dev $INPUT_DIR will be /c01/interface/dev and in test environment it is /u01/interface/test.
    I have tried this but there is still some probelm, I want to know is the approach I am using is correct? or is there any other solution for it?
    Regards,
    Sreejit

    Hi,
    1. physical name: use a specific directory (e.g. /u01/....
    2. logical name: use a LogicalDirectory like "InputFileDir" and rewrite this inside the bpel.xml
    http://download-uk.oracle.com/docs/cd/B31017_01/integrate.1013/b28994/adptr_file.htm#CACDEBBH
    and
    http://download-uk.oracle.com/docs/cd/B31017_01/integrate.1013/b28981/appx_deploydesc.htm#CHDBDIIF
    But what about creating a softlink like this on your testsystem:
    ln -s /u01 /c01

  • Does mxctrllib provide a call which returns a reference to all the logical names in MAX?

    I'm looking for a call that returns all the MAX logical names on a system. I would populate a drop-down box with those names to allow the user to select a name at program run-time. Currently I hard code a particular logical name as a string and init the session. This is not flexible. Thanks ...

    The NiMxCtrl.dll which is the server for the mxctrllib objects is meant for National Instruments internal product use only. There is no documentation for developing 3rd party apps that utilize its functionality.
    I'm not sure if you are talking about the IVI logical names listed in MAX or not, but if you want to know where you can get a list of these, they are in the ivi.ini file found in your C:\VXIpnp\Win95\niivi directory. Just parse this file to read all of your IVI logical names and setup parameters.
    Jason F.
    Applications Engineer
    National Instruments
    www.ni.com/ask

  • Using File Adapter with Logical Name

    I am creating a file adapter with Logical name. Apart from giving the Logical name is there any other configuration that I am suppose to do on the Web Logic before I start using it?
    Thanks in Advance.

    After configuring the file adapter, all you need to do is , give the path as a value for the logical name which you have created earlier. That you can do on the file adapter property inspector. There is no need to do anything on the server level. Lemme know
    Thanks,
    N

  • Finding a logical name for PXI5112 modules to be used in niScope_Init

    I need to dynamically allocate the number of PXI5112 modules on several PCs in a C++ program. After going through great length using VISA calls to obtain the VISA logical name ( PXI3::11::INSTR, etc.), I found out that niScope_Init is expecting an IVI or DAQ logical names. How does one go about to get the logical name for those PXI modules so niScope_Init can use? Hardcoding the name such as DAQ::1 is out of the question because the number of modules is different from test to test. Thanks.
    Software:
    niScope driver: 2.6
    Microsoft Visual studio.net 2003
    Measurement Studio 7.0
    Windows XP SP2
    Hardware:
    Group1 : 5 PXI5112s
    group2 : 3 PXI5112s
    group3 : 7 PXI5112s

    Here's a quick and dirty example of how to use the niModInst API in C:
    ViSession sessionHandle = VI_NULL;
    ViInt32 numberOfDevices = 0,
    i = 0;
    ViChar deviceNameBuffer[256] = "";
    niModInst_OpenInstalledDevicesSession(
    "niScope",
    &sessionHandle,
    &numberOfDevices);
    for (i=0; i < numberOfDevices; i++) {
    niModInst_GetInstalledDeviceAttributeViString(
    sessionHandle,
    i,
    NIMODINST_ATTR_DEVICE_NAME,
    256,
    deviceNameBuffer);
    printf("%s\n", deviceNameBuffer);
    niModInst_CloseInstalledDevicesSession(sessionHandle);
    The device names that you're printing out in this example can be used as the resourceName input to the niScope_init function.
    In practice, though, be sure to check the status that is returned from each function. You can get further information about an error using the niModInst_GetExtendedErrorInfo function. All the functions I used above can be found in the niModInst.h file.
    Hope that provides some more help.

  • Retrive logical names of table in oracle?

    Hi,
    Select * from tab;
    Gives the physical name of table....
    How to retrive the logical name of table?

    Duplicate post!
    retrive logicl names of table?
    Please stick to one post.

  • Server Name Shutdown Connection Prematurely

    HI,
    We are in process of doing load testing of the application. And at one scenario when, we keep 100 database connections, IAS max pool size 100 and IAS Study Pool Size 100, we get this error in Load Testing tool. And after successfull 20 user, it starts giving me error "<Web Server Name>Shutdown Connection Prematurely". And we are not able to test this scenario due to this. We tested another scenario when 1 database connection, IAS Max Pool Size 1 and Study pool size is 1. At this scenario we get 19 users going through successfully.
    Thank you in advance for help.

    hi..
    my server name is SERKANPROX\LOCALHOST No it isn't. Get the right server name. This problem has nothing to do with your username and password and such.

  • Problem with font logical names method

    Concerning font logical names, the Java tutorial states: To get the logical name for a Font object, call java.awt.Font.getName. Would someone kindly offer a few lines of code to demonstrate how getName would be implemented in this regard -- say using Century Gothic as the font? I've been having trouble overcoming error messages trying to implement this.
    Thanks.
    Jody Widelitz

    Pretty simple, just call getName() on a Font object once you have it. For example, this will list all the font names on your system:import java.awt.*;
    public class Test
        public static void main(String[] args)
            Font[] fonts = GraphicsEnvironment.getLocalGraphicsEnvironment().getAllFonts();
            for(int j = 0; j < fonts.length; j++)
                System.out.println(fonts[j].getName());
    }

  • Logical names lost after database corruption removal

    Hi,
    I am working on a PXI based project using NI 5663 and NI 5673. The MAX database in system got corrupted recently due to power cut.
    I did a database corruption removal and the only issue I face now is that there are no logical names for the devices. I am following the steps from the site below to create the same –
    http://www.ni.com/white-paper/4594/en
    But after I create a new logical name say for the LO 5652 (associated with 5663), I do not know which driver session to associate with it.
    There are driver sessions for niFGen, ni5450 in the list but no session for 5663 or 5673.
    Could someone please help me out with creating logical names and associating them to the devices?
    Thanks so much,
    Sharmi 

    Hello,
    To configure your 5663, you can refer to the RF Vector Signal Analyizer Getting Started Guide pages 37 - 39.
    You should open Measurement & Automation Explorer and rename the devices such as VSA_LO, VSA_DC, VSA_DIG for the local oscillator, downconverter and digitzer respectively. Next you will need to associate the downconverter with the local oscillator and digitizer by right clicking the downconverter and selecting properties
    To configure the 5673 the steps will be fairly identical, rename the devices if you wish and then associate the upconverter (IQ Vector Modulator) with the arbitrary waveform generator and the local oscillator. You can also refer to the RF Signal Generator Getting Started Guide on pages 23 - 24.
    Which programming language are you using the VSA and VSG with? You normally wouldn't need to configure any IVI sessions the the devices. The only configuration normally is just associating the upconverter or downconverting with the LO or digitizer/AWG module.
    Anthony F.
    Product Marketing Engineer
    National Instruments

Maybe you are looking for

  • HT201209 how can I buy an iTunes gift certificate for someone living in Colombia?

    How do I buy an iTunes gift certificate from US iTunes for someone who lives in Colombia?  The fine print on the gift certificate page says it can only be redeemed in a US iTunes store. Is this true? And if so is there a work around?

  • IDOC Generation Using XSLT Mapping[Query]

    Hi, I am working on File to IDOC scenario. I have used XSLT mapping. It is necessary to generate EDI_DC40 segment for IDOC in XSLT? -Kavita

  • Importing DVD video (burned by iDVD) back to editable format

    Is this possible? I burned a DVD of some video footage (so that I don't waste HD space with a large video file)--I cannot seem to import it with iMovieHD for editing or further manipulation.

  • ITunes 8.0 - Genius - unknown error 4010

    iTunes 8.0 gathers data about my music library well enough and sends it to Apple too; but then 10-15 seconds into "processing" by Apple, iTunes stops and reports that "Genius results can't be updated right now. An unknown error occurred (4010)." I th

  • SLD Parameter Object Server

    Hi! When I access http://<localhost>:50000/sld, then clicking on to Technical Landscape, I get an error "Please set the SLD Parameter Object Server first". I suspect that I haven't activated SLD.  So I searched on how to activate it and found this pr