Hi all,
I need some assitance to understand how can I run RHINTE00.
Our business scenario :
1. Integration will be active (an entry 'X' in t77s0)
2. I want to keep the text ( for eg of object position )maintained in OM with no truncation. 
Please assist. I alos would like to know what should be order of using RHINTE00 and RHINTE30.
Thanks and regards,
Anisha.

Hi Anisha,
To run RHINTE00 use TCode OOHP and for RHINTE30 use OOHQ.
If you have implemented PA and want to transfer datas to OM then use RHINTE00.
If you have implemented OM and want to transfer datas to PA then use RHINTE30.
Regards
Sairam Maharaj S

Similar Messages

  • Transfer one position from One Org unit to another -For multiple positions

    Hello All,
    I want to know is there any easy way to transfer one position form one org unit to diff org units? I <b>dont want to delete the position</b>, infact I want to transfer the same position (the position Id will remain same) to another org unit.
    I need to do multiple positions, hence pls suggest an easy way to do so.
    I know it can be done thorugh<b> PPOM -by drag & drop option ,</b> but the transfer record does not get stored in IT 0000 (actions) for the respective pers no.
    Hence, I want to easy wat, where we can do it for many positions , aslo the record gets stored in IT 0000. I tired with PA40, transfer action....
    but still more easiest way?
    Thanks in adv,
    N.babu

    Hello Nithi,
         Have a look at this link.It may help you.
    http://doa.louisiana.gov/hrhelp/content/orgm-changereportingstructuretoadifferentorganizationalunit/cc/html/index.htm
    Reward points if helpful.
    Regards,
    Manoj.

  • Securities -Positions transfer

    Hi expert,
    Is there a function in SAP Treasury to transfer securities positions from one partner to another partner within a company code at the book value?
    Regards
    Miroslav

    Hello,
    TPM28 is a T.code to do  class transfer in security account.
    To transfer the position from one security account  to another, Both the BP must be in depository bank role.
    Please make necessary setting in Account Assignment Reference Transfer.
    Regards,
    Jain

  • PA OM Integration

    Hello Experts,
    I have few questions arising from reports RHINTE00 and others
    I want to know if we are implementing only PA then do we have to maintain a table where we define org unit, positions etc?
    Now suppose we install OM as well, then when we run RHINTE00, Organizational Management objects like job, position, org units etc. are created in OM so my question is where do they get values from PA  as these objects are created in OM only?
    From this another question arises  Report RHINTE10 enables you to transfer objects created in Organizational Management to HR Master Data, where in Master data? Is it IT 0001.
    If it is IT 0001 then what function does RHINTE30 do because what I have read is - Report RHINTE30 enables you to update the Organizational Assignment infotype?
    What role does HRP 1000 etc tables have here?
    Also what is the difference between OM and PD objects? As per my understanding OM objects are org unit, positions and PD objects are qualification etc. what are personnel planning objects?
    Regards
    Kavita

    First of all set the below integration OM-PA switches active.
    Use the TCode OOPS or table name V_T77S0
    Plogi Orga = X (activates the integration between OM-PA)
    By this OM objects such as Organizational unit, position, job and cost center will be automatically assigned to employee while employee hiring in PA
    Plogi Plogi =1
    Plogi Perli = 999999999
    and go the feature PLOGI TCode Pe03 and it should be maintaiend X
    Then run the reports RHINTE 00/10/20/30
    means
    run the RHINTE Reports once
    before check all the records exists or not
    u2022 RHINTE00 - Transfer PA Records To PD Positions. In another world, it creates the HRP1001 between P to S in the OM side of the world. When you view a record via IT0001, you see this person holds the position, however via HRP1001, that relationship isnu2019t so.
    u2022 RHINTE10 - Generates the required relevant tables. (T513 - Jobs, T513S - Jobs, T528B - Positions, T528T - Work Center, T527X - Org Unit
    u2022 RHINTE20 - checks for all objects for integration between PA and OM. This is a big one and will take awhile to run. What it does is look at table T513/T513T - Jobs, T528/T528T - Position, and T528X - Org Unit. It will then compare it against the HRPxxxx table to find missing objects. If there are any missing objects, it will create the record.
    u2022 RHINTE30 - Transfer OM to PA. This will create infotype 0001. If the conversion strategy is to have SAP auto inherit factor to kick in for IT0001, often time jobs and org unit are missing via IT0001 during the inital conversion load. RHINTE30 will find the relationship and push it through IT0001.

  • OM infotypes not updated with relatioship.

    Hi Experts,
    I made one LSMW to upload info types 0000 (Actions) and 0001 (Org Assignment) using batch input recording method and successfully updated PA infotypes and verified OM info types 1001 (Relationships) for those positions (S) which I assigned new holders (P).
    But OM not got updated and is not showing the holder in those positions which I executed action.
    Can any tell me why it has not updated OM.
    With regards,
    Chandrasekhar
    Edited by: chandra sekhar on Mar 7, 2009 12:22 PM

    means
    run the RHINTE Reports once
    before check all the records exists or not
    u2022     RHINTE00 - Transfer PA Records To PD Positions. In another world, it creates the HRP1001 between P to S in the OM side of the world. When you view a record via IT0001, you see this person holds the position, however via HRP1001, that relationship isnu2019t so.
    u2022     RHINTE10 - Generates the required relevant tables. (T513 - Jobs, T513S - Jobs, T528B - Positions, T528T - Work Center, T527X - Org Unit
    u2022     RHINTE20 - checks for all objects for integration between PA and OM. This is a big one and will take awhile to run. What it does is look at table T513/T513T - Jobs, T528/T528T - Position, and T528X - Org Unit. It will then compare it against the HRPxxxx table to find missing objects. If there are any missing objects, it will create the record.
    u2022     RHINTE30 - Transfer OM to PA. This will create infotype 0001. If the conversion strategy is to have SAP auto inherit factor to kick in for IT0001, often time jobs and org unit are missing via IT0001 during the inital conversion load. RHINTE30 will find the relationship and push it through IT0001.
    Edited by: Sikindar on Mar 7, 2009 12:34 PM

  • Integration between organizational management and personnel administration

    Dear Sirs/Madams,
    I am trying to integrate organizational management and personnel administration to have see positions, jobs, and units which are assigned in PPOME. I made some configuration in T77SO and correct the needed integration in PLOGI position and especially for ORGA.
    Nevertheless, the integration problems did not solve. Now, I was wondering if you would mind helping me in this case.
    Thanks for your considerations,
    Kind Regards,
    Mohammad Hassan Salmani.

    To set up/fix full integration between PA and PD, run below reports in this sequence:
    1. RHINTE00 – Transfer PA records into PD positions –batch
    2. RHINTE20 – Create OM objects in PA tables – Online
    3. RHINTE30 – Bulk update of infotype 0001
    4. RHINTECHECK – Program to check PA to PD
    5. RHCHECKV - Checks all inverse relationships
    Also,It is important to realize that in PA, there are tables that contain objects from OM, i.e. for those items displayed on infotype 0001 Organizational Assignment. Sometimes the tables can get ‘out of step’ with those in PD – table HRP1000. Check those as well. The tables are:
    T513,T513S  Object type C (Job)
    T528B,T528T Object types S (Position) and A (Work center)
    T527X Object type O (Organizational unit)
    Regards,
    Mukesh

  • Things to do after BDC??

    Hi Folks
    I am running BDC with the help of Abaper to upload data in IT0000, IT0001 & IT0002 basically to generate employee code and run BDC for different infotype differently in future.
    BDC is running fine and i could see data in PA30 for the appropriate employees. After running BDC i observe that the position is not being attached with Person in PPOM_old/PPOME...
    This is absolutely working fine if i run Pa40 manually. because i could see person assigned with the position.
    Is there any thing i have to do after running BDC????
    Appreciate any help
    Regards
    Ragavan

    Hi Ragav,
    Its not necessary to run the programs after upload for IT0008, IT0009, IT0014, IT0015, etc. You have to run the programs after upload for IT0000 and IT0001.The programs have the following usage:
    RHINTE00                       Transfer Organizational Assignment (PA -> PD)
    RHINTE10                       Prepare Integration (OM with PA)
    RHINTE20                       Create missing objects (OM or PA)
    RHINTE20_ALT                   Check program for PA-PD integration
    RHINTE30                       Transfer org. assignment in batch input folder for infotype 0001
    RHINTECHECK                    RHINTECHECK
    Please check the documentation of these programs for further details.
    You have to run the program RHINTE20 and RHINTECHECK after the data uplaod for IT0000 and IT0001 is completed.
    Hope this helps!
    Please reward points and close the thread.
    Regaards,
    Rajeev

  • Page-break in alv background job for alv output variant not coming correctl

    Hi,
    I have created an ALV grid report. When i run the report in background i get the output with correct page-break on FIELD1. Now when i run the report in background with an "ALV output variant" (its the ALV variant that controls the fields display in the output; this is not the program variant), i do not get the page-break on FIELD1.  I have already build the sort criteria and using:
    gs_sort-group = '* '.     "New-Page
    Please let me know what could be reason for not getting the page-break in background when i am using the alv output variant and how do i correct this problem.
    Regards,
    Rakesh

    Hello Everyone,
    I have solved the problem. While running the program in background, we get the page-breaks when we use the below part of code in the sort catalogue with the condition that the program variant should not use any ALV layout variant.
    gs_sort-group = '* '.     "New-Page
    If you are using the ALV layout variant in the program variant then we can check the ROWPOS, COLPOS, and NO_OUT for that ALV layout variant and pass them along in the fieldcatalog table. You should be careful with not to pass the layout variant in the DISVARIANT. You can notice that i have cleared it and simply passing the program name into that.
    *C-- Process separately for jobs running in Background. Actually
    *C-- sortcat-group solves the problem only in Foreground. In background
    *C-- when ALV layout variant is not selected then it works otherwise it
    *C-- fails. So for background jobs we are reading the fieldcat and then
    *C-- passing the same in the display FM.
      IF sy-batch = 'X'.
        CALL FUNCTION 'REUSE_ALV_VARIANT_SELECT'
          EXPORTING
           i_dialog                  = ' '
           i_user_specific           = ' '
           i_default                 = ' '
    *   I_TABNAME_HEADER          =
    *   I_TABNAME_ITEM            =
            it_default_fieldcat       = gt_fieldcat
            i_layout                  = gs_layout
    *   I_BYPASSING_BUFFER        =
    *   I_BUFFER_ACTIVE           =
         IMPORTING
    *   E_EXIT                    =
           et_fieldcat               = lt_fieldcat
    *     et_sort                   = gt_sort[]
    *   ET_FILTER                 =
    *     es_layout                 = gs_layout
         CHANGING
           cs_variant                = gs_disvariant
         EXCEPTIONS
           wrong_input               = 1
           fc_not_complete           = 2
           not_found                 = 3
           program_error             = 4
           OTHERS                    = 5
        IF sy-subrc <> 0.
    * MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
    *         WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
        ENDIF.
        CLEAR gs_fieldcat.
        LOOP AT gt_fieldcat INTO gs_fieldcat.
    *C-- Transfer all position changes to gt_fieldcat from lt_fieldcat
          CLEAR ls_fieldcat.
          READ TABLE lt_fieldcat
                INTO ls_fieldcat
                WITH KEY fieldname = gs_fieldcat-fieldname.
          IF sy-subrc = 0.
            gs_fieldcat-row_pos = ls_fieldcat-row_pos.
            gs_fieldcat-col_pos = ls_fieldcat-col_pos.
            gs_fieldcat-no_out = ls_fieldcat-no_out.
            MODIFY gt_fieldcat FROM gs_fieldcat INDEX sy-tabix.
            CLEAR gs_fieldcat.
          ENDIF.
        ENDLOOP.
    *C-- Clear the disvariant for the background job as it contains the ALV
    *C-- layout varinat
        CLEAR gs_disvariant.
        gs_disvariant-report = 'ZGPPMP0001'.
    Then pass gt_fieldcat to 'REUSE_ALV_GRID_DISPLAY'.
    The reason i'm doing it this way is that when we pass the layout variant name, the contents in gt_fieldcat were getting modified.
    One more thing i'd like to point out is that that, i tried to delete the fields with no_out = 'x'. Now when i ran the program in background with all the fields in sort catalog (suppose there are 2 fields field1 and field2) also in fieldcatalog it ran fine. In the next run in background i removed one of the fields in sort catalog from the fieldcatalog (delete the fields with no_out = 'x') and i got dump. Basically i had hidden field1 and so the code which was deleting fields with no_out = 'x' deleted this field from gt_fieldcat. So basically we should not delete fields with no_out = 'x'.
    I was getting ABAP runtime errors    MESSAGE_TYPE_X in the following part of the standard code.
    000310     LOOP AT CT_SORT INTO LS_SORT.
    000320
    000330       READ TABLE IT_FIELDCAT ASSIGNING <LS_FIELDCAT>
    000340            WITH KEY FIELDNAME = LS_SORT-FIELDNAME BINARY SEARCH.
    000350       IF SY-SUBRC NE 0.
         >         MESSAGE X000(0K).
    000370       ENDIF.
    000380
    000390       LS_SORT-SELTEXT = <LS_FIELDCAT>-SELTEXT.
    i have just mentioned this part because when i checked the forum many people were getting such errors "MESSAGE_TYPE_X". This could also be one of the reasons.

  • Posting with MM Movement Type 309 material to material: Error in WM

    Hello,
    i post an MM-Movement type (Bewegungsart) 309 (material to material).
    The MM-goods movement works, but then in warehouse mangagement there is a problem:
    The creation of the transfer order (Transportauftrag) stops in many cases.
    The aim is to post Material A to the same storage bin in Warehouse Management where Material B was before.
    I programmed this in user-exit (ZXLToU03) that by movement type 309, always taking same storage bin. But then I often get the error: transfer order could not be created. Then I have to do the creation of tranfer order in foreground and then I get an error like this:
    capacity of the bin location is not enough.
    The Problem is that I do a posting for example:
    001 010101                   to     922 Umbuchungzone    -->  Transfer order Pos 1
    922 Umbuchungszone  to    001 010101                    --> Transfer order Pos 2.
    And so the first transfer order position is not confirmed when I do the transfer order Pos 2.
    How can I confirm Pos 1 by batch-input? The Programm to do 309 should posting 1000 materials in one step. But in Warehouse management I get those problems?
    Is it possible to increase the capacitiy of the storage bin and then decrease it after creation of transfer order(where can I do this and when)???
    I hope anybody can help me.
    Thanks.

    Hello Kevin,
    I donu2019t think it is necessary to use a user exit to keep the Material B (that is transferred from Material A) in the same bin.
    This can be controlled in the customizing: indicator Post to same bin, that can be set in the WM Movement type (V_T333-KZUAP) and in the Storage type (V_T3010-KZUAP).
    Now I donu2019t know your business process but I am surprised that Material B requires more space than Material A since it is u2018bornu2019 by means of a transfer posting and not a production or packing step that makes it bigger in terms of capacity required.
    A workaround for this could be to transfer (LT10) Material A first to a separate Storage type (with the Post to same bin-flag set) that has no Capacity check and after the 309 posting transfer it back into the warehouse with LT10.
    Success and thanks beforehand for any credits!
    Kind regards,
    Bart

  • OM problem in transporting the request

    Message no. 5W612
    Diagnosis
    The system has transported a relationship to the specified object of an object currently being activated. However, the relationship cannot be activated.
    The problem is usually caused by the related object not being available in the target system.
    System Response
    The object is transported correctly but without the specified relationship.
    Procedure
    Make sure that the related object is available in the target system, or that it is included in the same transport request as the current object, before you repeat the transport.
    If the related object is not required or must not be available in the target system, no further action is required on your part.
    can any one tell me on this

    Hi Sikinder,
    You can try with OM reports like,
    RHINTE00  - transfer organizational Assignment.
    RHINTE10  - prepare Integration.
    RHINTE20 - Create missing Objects
    RHINTE30  - ransfer Org.assignment in batch input folder for infotype 0001
    These reports may help you to find the relationship where you can have so many selection options.
    I think defiitly these will help you.
    Reward me if helps,
    Vasu.

  • Movement type 311 E in WM

    Hi gurus,
    I am working on product support @clients place where we have MTO items.
    Now the scenario is that a material XYZ was Goods Receipted in a wrong storage location (0001) by the Production Order confirmation. This was due to the way it was setup was incorrect.
    So to create a Delivery for these items, I had to move the stock from the current location (0001) to another location(0002) in the same plant.
    For this I used MB1B - 331 E. This worked fine on the IM side.
    Now on the WM side there was an entry e.g. 0001 E - Storage type (010) before the change was done.
    After the change, the transfer posting entered a negative entry for the same quantity of the item. However this negative entry is lying in the Interim storage type 992 e.g. 0001 E - Storage type (992)
    I want to nullify these 2 entries. So i read on some forums & thought of doing a LT01 and transfer the positive value from 0001 E - 010 to 0001 E - 992.
    However for storage type 010, negative stock is not allowed.
    I am confused & dont know what to do in this case.
    Can anyone tell me how to nullify this WM stock ?
    Your help will be really appreciated.
    Thanks
    Dan

    Hi,
    If my understanding is correct. You want to transfer post a stock of material from one storage location to another ( IM perspective ) and from one bin to another bin belonging to different storage types but same plant ( WM perspective ).
    As this transfer posting does not involve any Sales order what is the logic behind the selection of movement type 311 E.
    I hope you can very well make use of 311 movement type for the transfer posting in IM which will lead to the generation of a PCN in the WM side. On confirming the same you will be able to do the reflection of Transfer posting in WM side also.
    I would suggest you to follow the above steps.
    1) First check the transfer posting 311 E which you have already completed a PCN in the background. If it is availble, just try to confirm the posting Change notice which will clear off the negative entry and a correponding postitive entry in the receiving storage type.
    2) In case if the system have not generated the PCN, then better to cancel the material docuemnt and re do the transfer posting to carry out the process from the start with the movement type 311 which will yield a PCN which can be confirmed to see the stock in the required storage type and in the respective bin accoring to the strategy set.
    Regards,

  • E- recruitment requisition not functioning well!

    Hi all!
    I was doing the configuration of the SAP e-Recruitment. The problem which i am facing is that i am not able to attach the vacant position number to the requisition which i am creating. Can any one through light on this.
    Points will be awarded to the person solving the problem.
    Regards
    Saurav

    Hello Saurav,
    positions are assinged on the organizational information tab of the requisition maitanance container sequence. If you use the standard configuration it should be the 2nd tab in the recruiter view. The tab hase a "subsequence" where it is the first tab. This should be visible if not modified as customizing this subtabs will be implemented with ehp3 which is not released yet.+
    In the database this assignment is stored as releation between these 2 objects in IT10001.
    If you are on an integrated system the positions should be available. If you are on an alone installation you have to transfer the positions before assigneing the viw ALE of course. Please note that the vacant flag is not transfered with the ALE so it has no effect for E-recruiting standalone installations. You will find all positions in the search.
    If you are in an old installation you might face the problem that you miss a note which fixes the problem that positions stating in the future were not found in the search but this is quite unlikely as it is really a very old note.
    Best Regards
    Roman Weise

  • Plotting on xy graph based on mouse coordinates

    I am looking into plotting Mouse coordinates on XY Graph continuously based on where i move. My computer's resolution is 1200x800 and i would like it to plot based on where i move.,
    Attached is my progress so far.
    Attachments:
    progress.png ‏74 KB

    The XY Graph has a method which converts coordinates to XY values. You can call it by right clicking the graph and selecting Create>>Invoke Node>>Map Coordinates to XY.
    However, if you look at the help for it, you will see that the coordinates it expects are those of the pane the graph is in, and the coordinates you have are of the screen. You can convert your global coords to pane coords by getting the VI's Front Panel Window. Panel Bounds property, building two matching XY clusters from the data and subtracting them (assuming the VI only has one pane) or you can use another loop with an event structure and a Mouse Move event (which returns local data) on the graph and then transfer the position data to your loop (you could also use a single loop, but that might be more complicated because the event structure will process every move of the mouse as a new event).
    You will also need to keep the data to place in the graph somewhere. If you open the context help window and hover over the graph's BD terminal, you will see the data types it expects and you will need to build one of those yourself. A shift register is something you might want to look into. There are also some examples showing working with graphs in the example finder (Help>>Find Examples).
    Try to take over the world!

  • How to use nokia as a gps antenna for sailing navi...

    hi to everyone.
    it's time for me to buy a new phone and i was interested in the 6110.
    I was wondering . does anyone know if it's possible to use the phone as a gps antenna and connect it to a laptop so i can use the laptop's programs and maps which are specific for sailing navigation?
    maybe through some program for its s60 platform?
    I mean i want the nokia to transfer the positioning infos on my laptop. there are already some external antennas-receivers for this job that are connected through usb or bluetooth but i 'd like to know if i can do that with my nokia.
    thanx in advance for your time

    Hi argotera
    Unfortunately this is not possible as internal GPS is an embedded chip which can only be accessed by applications installed upon 6110 Navigator.
    Happy to have helped forum in a small way with a Support Ratio = 37.0

  • HOW TO INTEGRATE ENTERPRISE STRUCTURE, PERSONNEL STRUCTURE AND ORGANIZATION

    HOW TO INTEGRATE ENTERPRISE STRUCTURE, PERSONNEL STRUCTURE AND ORGANIZATIONAL STRUCTURE?

    Hi assuming u r looking at OM-PA INTEGRATION
    find these relevant reports u've got to run.
    RHINTE00 Transfer Organizational Assignment (PA -> PD)
    RHINTE10 Prepare Integration (OM with PA)
    RHINTE20 Create missing objects (OM or PA)
    RHINTE20_ALT Check program for PA-PD integration
    RHINTE30 Transfer org. assignment in batch input folder for infotype 0001
    RHINTECHECK also is useful.
    also the ensure in T77S0 integration switch PLOGI ORGA X(is activated)Feature PLOGI.