RM887- change rem profile regarding generation of postprocessing records.

Hi,
While doing MFBF (GR GI) I am getting error "change rem profile regarding generation of postprocessing records" Message No RM887. I am using same REM profile for many other materials for which MFBF is working fine. There are no COGI errors pendings for the materials for which I am gettinh error. But in MF47 there are some pending records which I neither can change nor delete, I am geting same message as in MFBF in MF47. So I have two issues here 1) How to adress error in MFBF. 2) Why records are seen in MF47 and not in COGI?
Thanks
Suresh.

Dear,
Please refer the OSS notes 383141,202654, 885798.
In OSP2 Transaction, check whether the REM Profile having the Tick for "Create Cumulated post processing records".
If this is not there, and allowing the entries to go to COGI with Execute Correction in dialogue mode "Optional" will be a problem
Please try and come back.
Regards,
R.Brahmankar

Similar Messages

  • Kanban : Changed REM profile regarding generation of postprocessing records

    Dear Gurus,
    I am trying make a kanban container from empty to full and i am getting the below error message.
    Changed REM profile regarding generation of postprocessing records - RM887
    I have not change the production version or rem profile. This error is when i scan them to FULL so I have not used "Execute correction in dialog box mode" option in OSP2. NO COGI errors...
    Any advice is highly appreciated.
    Regards,
    Senthil
    Edited by: Senthilkumaran Virudhanayagam on Feb 24, 2010 3:54 AM
    Edited by: Senthilkumaran Virudhanayagam on Feb 24, 2010 3:55 AM

    Dear Senthilkumaran,
    Was there any changes made in the REM profile in OSP2 related to creating individual post processing records or cumulated,if not
    was the REM profile changed in the material master?
    Can you please check this and reply?
    Regards
    Mangalraj.S

  • Changed REM Profile regarding generation of postprocessing records

    Hello Team,
    I have tried to backflush a part number. I get this error:
    Changed REM Profile regarding generation of postprocessing records
    The intrigue here is that this same part number was backflushed last week without error.
    I will appreciate your inputs.
    Thank you in advance.

    Joel,
    Check the material master for changes in REM Profile assignment, looks like the REM profile assigned to the material does not allow Post Processing records, so if there are errors during backflush like less stock, no storage location, batch not assigned, system would give error and it would not allow you to post the backflush.
    If there are no changes in the material master for REM profile assignment then the assigned REM profile itself must have been changed in configuration in the path mentioned by fellow forum member. Please check and for "Error correction for backflushing" section definations.
    Regards,
    Prasobh

  • Bacgflush error: Change REM profile

    Hi Gurus,
    I have tried to backflush a part number. I get this error:
    'Changed REM Profile regarding generation of postprocessing records'.
    From my knowledge we didn't chnge the REM profile and product cost collecter is also avilable.
    Please help to resolve the error.
    Thank you.
    Naveen

    Dear Naveen,
    Check whether did you make any config changes in the REM profile in OSP2 or else assigned some other REM profile which
    allows reprocessing.
    In my understanding if already some reprocessing exists for that material in MF47,and if you try to change the REM profile and
    try to backflush,this will give this error.
    Check and correct me if i 'm wrong.
    Regards
    Mangalraj.S

  • Issues in REM Profile(AGI)

    Hi Gurus
    We are working of REM , we are using AGI Profile for Goods issue, from last 3 or 4 days we have started facing problem in that
    when we are running AGI , it is giving message (Changed REM profile regarding generation of postprocessing records & Collective mess. for mat. XXXXin plant XXX with version 0001 not executed on 20100319* )*  in this it is showing for one or 2 material whereas it is runnning fine for other materails
    It is also running fine for other 2 plants
    Please help me

    Hi,
    1. Did u change the Rem Profile any time recently ?
    Reg
    Dsk

  • REM profile

    Hi,
    In Repetitve Manufacturing , i was doing Assembly backflush.
    If i want to do Activity backflush with reporting point, ( I have maintained Milestone control key also in Routing) whether i have to change my REM profile in Material master.?
    If i am changing , system shows the error related to costing.
    Help me out of this. I would like to understand this process clearly.
    Santhosh.

    Dear Santhosh,
    Assuming you have made the configuration changes to the existing REM profile in T.Code OSP2,now modify your routing/rate
    routing with operations containing milestone confirmation set control key.
    If my understanding is correct then I dont think a new PCC is required for the same material.Instead in KKF6N--->enter the
    material,plant,select the production version,now click on change mode--->Shift+F6 and then click on cost calculator for pre.cost
    estimate for the product cost collector(Shift+F1) and then save the data,now check in MFBF as I have explained in my earlier
    thread.
    check and revert back,
    Regards
    Mangalraj.S

  • Bloqued Stock Default into REM Profile

    Hi everyone:
    I need to know how can i be able to set the Stock Type to REM Profile, 'cause I need that the result of the Posting into MFBF T.code be Blocked Stock, instead of, Unrestr. Stock.
    I was trying by the REM Profile into: IMG guide: Production> REM > Control > Profile...  but... I don't get to find out the check or the configuration parameter to set this stock type. I know that into the MFBF there is a function with F5 to Change Detailed Setting but, I need this parameter pre set for all access into that screen and don't is changing it each time i go to this T code.
    Please & Thanks in advance for your help.
    Regards
    Omar Perea

    Hi OMAR ,
    Could you pleasse breif How you did the setting, even i require GR atomatic By MFBF, I tried with 103 it is giving Below error ,
    Update control of movement type is incorrect (entry 103 X X _ F)
    Message no. M7226
    Diagnosis
    The system could not find entry 103 X X _ F in any of the movement type control tables.
    Procedure
    Cancel current processing.
    Contact your system administrator.
    Action to be taken by the system administrator
    Check in Customizing for Inventory Management under Copy, Change Movement Types whether the entry is contained in the Update control view for the movement type.
    If the entry is missing, proceed as follows:
    For standard movement types, this means that the given process is not supported using the present data combination. Do not create any entries without prior arrangement with your SAP consultant. Otherwise, incorrect postings may result.
    For customer-defined movement types (beginning with 9, X, Y, or Z), this may mean that they have not been fully defined. Delete the movement type and re-create it by copying a standard movement type.
    so could u explain me the process how u did ,
    Thanks in advance.
    Madhu

  • Diff bet REM profile

    Hi,
    What is the diff between REM profile 0001- W/o activity backflush & 0002 - with activity backflush. Is it activity backflush is necessary?
    Regards,
    Dharma

    hi Dharma,
    the only difference between the
    >Final backflsh w/o activities profile 0001 &
    >Final backflsh w activities profile 0002
    is that in profile 0001 u cannot post the activities to the product cost collector while in profile 0002 u can when u backflush.
    the activities which are posted in the to the collector can be done based on
    >standard cost estimate
    >preliminary cost estimate
    standard costing is done usually at the start of the year and is not changed while preliminary costing calculates the costs for the  production process which can be for a particular production version or for a combination of BOM or Routing.
    so choosing between these two profiles depends on how u want the capture the cost while backflushing.
    hope this gives the required info
    regards,

  • User Profile Incremental Sync does not views changes in profiles.

    User Profile Incremental Sync does not views changes in profiles. I make full sync - all ok. then I change the phone number for example, and then start incremental sync and nothing moves to AD. 
    All the stages of FIM sync just state 0 records to process. Looks like it does not see the changes
    1.profile property is set up to sync with AD attribute (with EXPORT).
    2.no errors in Windows logs or FIM UI client, nor in sharepoint UI
    3. sharepoint server 2010 SP1, "CU June 2012"  14.0.6123.5002
    4. I have just reprovisioned sync service, set up AD connections and property-attribute relations. before
    there was this problem http://social.msdn.microsoft.com/Forums/en-US/cb2b8aeb-d1b6-49a6-a788-2491ca45308a/critical-error-6398-userprofileimportjob-problem-profile-sync-malfunction?forum=sharepointadminhttp://social.msdn.microsoft.com/Forums/en-US/cb2b8aeb-d1b6-49a6-a788-2491ca45308a/critical-error-6398-userprofileimportjob-problem-profile-sync-malfunction?forum=sharepointadmin,
    which I resolved by clearing timer service cache.
    Help with advice, urls or solurions please..

    Hi  VlH,
    According to your description, the issue can be caused by the Profile or Profile Values table.
    You can check the event log and ULS log to see detail error message.
    To check event log, click the Start button and type “Event Viewer” in the Search box.
    For SharePoint 2013, by default, ULS log is at      
    C:\Program Files\Common Files\Microsoft Shared\Web Server Extensions\15\LOGS
    For your issue you can refer to the similar thread:
    http://social.technet.microsoft.com/Forums/sharepoint/en-US/bc3cd2ff-dc12-4223-a80b-e4cae616e861/user-profile-sync-doesnt-update-the-profiles-from-ad?forum=sharepointadminlegacy
    Also a good blog for user profile synchronization:
    http://www.harbar.net/articles/sp2010ups.aspx
    Best Regards,
    Eric
    Eric Tao
    TechNet Community Support

  • REM profile Product Type - Cost Collector Order Type

    Hi all,
               I am trying to create a Repetitive Manufacturing Profile, at that time standard Production Type PKMN is automatically arriving from table V_T437S_GES.
    and I would like to assign the cost collector order type (self defined) to the REM profile which I am going to create.
    where I need to assign the cost collector order type for production type "PKMN" while creating REM profile.
    If I copy the exisiting REM profile and I am able to get the cost collector order type  that I am able to see in TABLE : T437S (Repetitive Manufacturing Profile Table). If I create the REM profile newly, I am unable to get the cost collector order type in the table T437S.
    So please guide to the self defined cost collector order type for newly creating REM profile.
    Thanks in Advance

    Madhan,
    Order type "PKMN", is internally defined by SAP. Forr all cost accounting purpose, we would be using standard order type "RM01" when creating a new product cost collector for material. If required you can create your own order type say "ZM02" using transaction KOT2, please remmember you need to create with order category "05"- Product Cost Collectors.
    This new Order type can be used when we are creating product cost collectors for a material.
    I really dont find a reason why a new Order type is required to be created. Can you explain why?
    Regards,
    Prasobh

  • Windows 2012: change network profile

    Hi i have a query, how to change network profile to public from domain in a server on Windows 2012?
    Best regards
    Edgar 
    Best Regards Edgar

    Hi,
    Thanks for your post.
    If the server is domain joined, when it starts to detect the network location, the machine will contact a DC via port 389. If this detection successful, it will get the domain profile. And we cannot change it. If the domain was not found or process failed,
    NLA will let you to determine which firewall profile will be used, private or public.
    For more information about Network Location Awareness, you may refer to the following article. It also applies to Windows 2012.
    Network Location Awareness (NLA) and how it relates to Windows Firewall Profiles
    http://blogs.technet.com/b/networking/archive/2010/09/08/network-location-awareness-nla-and-how-it-relates-to-windows-firewall-profiles.aspx
    Best Regards,
    Aiden
    TechNet Subscriber Support
    If you are
    TechNet Subscription
    user and have any feedback on our support quality, please send your feedback
    here.
    Aiden Cao
    TechNet Community Support

  • Changing dynamic profile-parameters in batch

    Hello,
    want to change dynamic profile parameters (rdisp/btctime) in batch.
    I know that i can change this in Transaction RZ11 - but i must change it, depending on our
    batchstrategy in the night.
    best way for me - is to change it via batchprogram - with variant 'parameter' - 'value'.
    thank you for help
    best regards
    L.Misof
    R&S

    Hi,
    why don't you use the operation modes for increasing batch work processes in night ?
    Thanks
    Sunny

  • Change of Profile email

    Hi All,
    I would like to change the profile email such that I receive all the notifications from SCN.
    But I was unable to find the same in the profile settings. Can anyone help me to change the ID?
    Thanks in advance.
    Regards,
    Narender.

    Just put some effort in searching.. There are too many discussions here about changing email id..
    Have a look into the document Everything I know about... Managing SCN eMail Notifications or just click into this LINK.
    **Edited by: Dëv Päträ

  • Backflush and REM profile and control key ...

    Hi all,
    in REM manufacturing, the backflush is control by routing control key or  REM profile settign in configuration ?

    HI..
    In REM scenario the backflush is controlled only by REM Profile.u can configure it in SPRO.
    path is ..production> Repetitive manfacturing> control data> rem profle
    u can create with the help of assistant given in SPRO
    plz revert me if it works for u
    Regards
    Anupam Sharma

  • REM profile for finished material and its raw material

    Dear Experts
    My question is ,for a repetitive manufacturing scenario
    1) We are maintaining REM profile finished material . Is it necessary to maintain REM profile for its raw materials ?
    2)For raw materials do we need to create the seperate REM profile which is having seperate stock determination rule ?
    Regards ,
    Vishwas.K

    Dear Vishwas,
    1.REM profile assignment is required only for the materials for which production confirmation will be made through T code MFBF or
    MF42N.
    2.For stock determination rule check in control data 2 in the REM profile itself. This setting is linked to the REM profile and further to
    the goods movements posting for the raw materials.(check this setting in T code OSP2).
    Regards
    Mangalraj.S

Maybe you are looking for

  • HT3887 How can i connect my Dr Dre wireless headphones to my mac pro,

    when i try connecting my headphones to my mac it keep saying that there was an error

  • Broken micro SD card in Nokia 6300

    My friend has a 6300 and stuck the micro sd card in upside down, then proceeded to break itin two, with a bit of the card lodged in the phone. What I want to know is there any way I can open up the phone to open up the slot to remove the piece of the

  • Adobe Reader automatically removes itself

    Hey, I need some help. One of the laptops at work needs Adobe Reader installed for PDF use. I install it, however, after every system shutdown, Adobe Reader is automatically removed and i have no idea why. I've tried googling this, with not luck.. Ha

  • Two questions: about volatile and operator

    Howdy! I need a little info on these lil' critters I've got here... First: What is the volatile modifier...? What does it do...? And second: What is the >>> or <<< operator...? First I just assumed they were bit rotation, but now I'm not so sure... I

  • Cisco 1841 with 2 public WAN IP's and NAT

    OK currently the network is setup as follows: Zyxel SHDSL Router --> Linksys Router --> 10/100 Switch --> PC's x.x.x.145/28__________x.x.x.146/28____________________192.168.1.0/24 The Linksys router is running inbound one-to-many PAT (eg. x.x.x.146:8