RME 4 - Inventory Collection Failure

I am getting the following RME inventory collection error on 4 devices.  These 4 devices were recently added to the network and were all attached to a new radius server.  I have tested AAA to the 4 switches and am confident that radius is working as intended.
The devices are a mix of 2950 and 3550 switches.
Here is the error.
RICS0001:Internal Error,unable to process the collected data from the device.
Thanks in advance.

In that case, this is probably CSCsk65355 which should be fixed in 4.1.1.  However, 4.1.1 suffers from CSCsm97530.  So I would suggest to first upgrade to RME 4.1.1.  If you continue to see this, then you can contact TAC and apply patch for CSCsm97530 over 4.1.1.

Similar Messages

  • Inventory Collection Failure Following Upgrade to 3.2

    We have 90 Cisco VPN 3002 Hardware clients deployed that we manage using Ciscoworks. Before our recent upgrade from 3.1 to 3.2 all VPN 3002 devices previously inventoried and fetched configs successfully.
    Following upgrade this week we are seeing Inventory Collection failures for some (not all) of the VPN 3002 devices.
    Not sure if upgrade from 3.1 to 3.2 installs a new device package for this device, but checked following upgrade and there are no Software, Device or Package updates on CCO that we need to install.
    I have attached output from IC_Server.log for one of the failed VPN 3002 devices and it looks like the Inventory Collection failure is SNMP related (see attached).
    Any idea if we need to upgrade code on the VPN 3002 devices? I tried deleting device from Ciscoworks and readding without success and Config Fetch is working on readded device.

    There appears to be a problem getting the ifTable from these devices. It would be helpful to see a sniffer trace filtering on SNMP traffic to one failing device, then on one successful 3002 when performing inventory collection to see if there are any obvious problems. The device is replying with a noSuchName error, but it's not obvious exactly which object is causing the problem.
    The other error here is related to the following Altiga objects:
    alSepModuleStatsType
    alSepModuleStatsState
    alSepModuleStatsDspCodeVersion
    Again, a noSuchName error is coming from the device.
    There were no code changes in the 3.2 device package for VPN3000 devices, so something must be going on with these devices.

  • RME 3.2 Inventory Collection Failure with error

    Hi,
    Inventory collection fails with error is "Timed out. Make sure that ICServer is running”. But the ICServer process is running. I enabled debug on could see the following in the IC_Server.log which I'm not sure if it indicates any issues.
    I can find the devices in DCR and the devices are classified as Normal in RME.
    Series of following message for all the devices
    DEBUG,[Thread-26],com.cisco.nm.rmeng.inventory.ics.core.Request,115,Removing device 181from request 1255347128972
    DEBUG,[Thread-26],com.cisco.nm.rmeng.inventory.ics.core.PriorityQueue,163,Removing, 175
    DEBUG,[Thread-26],com.cisco.nm.rmeng.inventory.ics.core.PriorityQueue,171,got device, 175
    DEBUG,[Thread-26],com.cisco.nm.rmeng.inventory.ics.core.Device,51,Removing request 1255347128972 for device 175
    DEBUG,[Thread-26],com.cisco.nm.rmeng.inventory.ics.core.PriorityQueue,177,Removed2 dev, 175from Priority of the ENUM is : 0
    then,
    DEBUG,[Thread-25],com.cisco.nm.rmeng.inventory.ics.core.PriorityQueue,89,Adding Device :175
    DEBUG,[Thread-25],com.cisco.nm.rmeng.inventory.ics.core.Device,46,Adding request 1255347128973 for device 175
    DEBUG,[Thread-25],com.cisco.nm.rmeng.inventory.ics.core.PriorityQueue,142,Found dup device in queue: 175
    DEBUG,[Thread-25],com.cisco.nm.rmeng.inventory.ics.core.Request,75,Adding device 175 to request 1255347128973
    and then the below messages
    DEBUG,[Timer-0],com.cisco.nm.rmeng.inventory.ics.threadpool.ThreadPool,69, Timer Tasks Run method is called.
    DEBUG,[Timer-0],com.cisco.nm.rmeng.inventory.ics.threadpool.ThreadPool,69, Timer Tasks Run method is called.
    DEBUG,[Timer-0],com.cisco.nm.rmeng.inventory.ics.threadpool.ThreadPool,69, Timer Tasks Run method is called
    I highly appreciate any help on this. Thanks

    The ICServer process could have locked up which means a full thread dump will be required to see why this is happening. Open a TAC service request, and they can walk you through getting this.

  • Inventory Collection Failure with LMS 3.2

    Hi,
    I've been running LMS 3.2 with RME 4.3.1.
    Inventory Collection fails while trying to collect data from 7825I Media Convergence Servers running Call Manager 6.1.
    It fails with the following error:
    RICS0001:Internal Error,unable to process the collected data from the device.
    I have tried deleting and adding the device again, but with no effect.
    The Call Manager server has ip 192.168.5.5, here it is the IC_Server.log attached.
    Looking at the log, I see there is some kind of database error, but I don't know how can be avoided.
    Any suggestions?
    Regards,
    Velin

    I have removed the Call Managers from RME, and then re-added them again.
    After that I started a inventory collection job but it failed again with the same error. I've tried some times with the inventory job but it fials every time.
    I read about the bug you've mentioned and it is advised to patch the RME. Since i'm running the latest version, what can i do?

  • RME 4.3, Inventory Collection doesn't work for 6500

    I have a issue with Inventory collection for 6500 devices running IOS 12.2.33 SXI1, fails with a message, "device collection failed"
    From IC_Server log i could see SNMP Request timeout exception, so increased SNMP timeout to 10  under device attributes for the device but still it fails.
    attacehd is the extract from IC_Server log.
    Could anybody help me on this? Thanks

    You have not increased the timeout properly.  You need to go to RME > Devices > Device Management > RME Devices, and edit the attributes for the required device.  Select the device from the list in the left-hand pane to pre-populate the current attributes.  Then increase the SNMP timeout to 10, and save the changes.  On the previous screen, you will need to APPLY those changes before the 10 second timeout will take effect.

  • LMS 3.0.1, RME 4.1.1 - Inventory Collection Status displays too many device

    Running LMS 3.0.1 with RME 4.1.1 on a Windows box. On the Inventory Collection Status screen I see the following:
    Inventory Collection Status No. of Devices
    Inventory Collected: 1246
    Inventory Never Collected: 0
    Inventory Recently Failed: 34
    Total 1246
    The problem with this is that I only have 668 devices. Is this just a cosmetic issue?

    Assuming you're not integrated with ACS, then yes.  If integrated with ACS, some of the devices may not be authorized.  You will need to check your ACS configuration to make sure all devices in LMS are known to ACS and that your user (and the System Identity User) is authorized to manage them.

  • Prime Infrastructure 2.0: Inventory Collection - Partial Collection Failure on 2 of 4 VSS WS-C6509-E

    Hello,
    I've got a strange behaviour regarding the inventory collection for 2 of 4 virtual switching systems.
    That means the inventory collection for two VSS is succesfull (inventory collections status = Completed) for the other two systems it is not, see attachments.
    The device credentials like SNMP-RW, SSH acces are OK. I've already tried to increase SNMP timout and retries as well as telnet/ssh timout without success
    All 4 systems are identical regarding hardware model and software vesion.
    HW: WS-C6509-E
    SW: 12.2(33)SXJ3
    Any ideas or suggestions?
    Best regards,
    Bastian

    TAC and I found a bug, CSCum05301.
    May be that is also helpfull for others.
    https://tools.cisco.com/bugsearch/bug/CSCum05301/
    Symptom:
    Inventory collection will fail if following keywords are used as part on description command on the interface config level of IOS device: 1Gbps, 10Mbps etc.
    Following error message is visible on the DWC:
    Inventory Collection Status: Partial Collection Failure
    Collection Status     Failed feature(s)
    Unable to configure DSL, Serial, POS, Ethernet, Loopback, Virtual-Interface, Tunnel, Vlan, Switchport and Service Module interfaces on ISR, ASR and Switches.
    Conditions:
    Speed keywords like 1Gbps, 10Mbps etc. available as part of descrption command in IOS interface level.
    For example:
    interface FastEthernet0/3
    description 10Mbps
    Workaround:
    Use a space character between number and unit keyword, like 1 Gbps.

  • Inventory Collection problem for RME 4.3.1 LMS 3.2

    I recently upgraded from LMS 3.1 to LMS 3.2 and RME v 4.3.1. I have problems with the inventory collection. It will start scanning, but stops after approximately 10 devices. The rest of them will have a pending state. If I stop the collection job and start it again none (0) devices will be scanned. If I restart the ICServer it will result in the first option. That is, it will scan only 10 devices and then stop. I have extended the SNMP timeout to 30 secs and zero retries. Any suggestion would be appreciated

    I have read through the dump and cant find anything in particular. Another discovery I've made is that the SNMP walk of an unsuccessful device takes 10 times longer than a successful device. An inventory job on a unsuccessful device only goes into pending and the job never starts.

  • LMS 3.2 - RME 4.3.1 Inventory Collection never stops (Job Result = pending)

    Hello all,
    with our LMS-System running on Solaris 10 we have the following problem:
    - Inventory Collection never stops after starting
    - This can be seen with all devices or 1 device selected
    - Config-Mgmt is working
    - After re-init of RME-DB the problem persists
    In Logfile (IC_Server.log) no problems are shown.
    In Job-Logfile only the collection request is shown.
    Any help is appreciated
    Thanks for your feedback
    Lothar

    Hi Joe,
    with further troubleshooting this problem I discoverd the following.
    - Having problems with inventoring certain Cat4000 we requested patch for Bug-ID CSCtb16925 (LibInventory.zip-File).
    - Replacing this file with the old one or installing the newest IDU for RME the problem was solved.
    It seems that the LibInventory.zip file given with Bug-ID CSCtb16925 is somewhat buggy (maybe in context with device-number) greater
    than 1000.
    Thanks for your support.
    Lothar

  • LMS 3.2 RME 4.3.1 Inventory collection failing for switches

    I have 6 switches that inventory is failing for.  They do run the 12.2(33)SXI3 software but I have the CSCtb16925-1.0  patch installed.  I've tried to increase the SNMP timeout for the devices but they still fail.
    Ideas?
    Chris Jasztrab

    You did not properly increase the SNMP timeout.  Go to RME > Devices > Device Management > RME Devices, and edit the attributes of the device in question.  Perform an inline edit.  Click on the device name, then change the existing SNMP timeout value to 10.  Then save your changes, and apply them on the previous screen.  Then inventory collection should work.

  • RME 4.3.1 Inventory collection failing for cisco 3925

    Hi,
    I've a customer having LMS 3.2 and RME 4.3.1. He has 14 Cisco 3925 routers out of which inventory collection for 2 fails.
    Router IOS is: c3900-universalk9-mz.SPA.150-1.M.bin".
    Can someone suggest what might be going wrong? Attached is the  IC_Server log file for reference.
    Thanks in advance,
    inner_silence

    Hi,
    Here are the exception found from the log :-
    [ Fri Mar 18  16:28:24 EDT 2011 ],ERROR,[Thread-17],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,729,Exception for device 10.103.251.12 is
    java.lang.reflect.InvocationTargetException
        at sun.reflect.GeneratedMethodAccessor12.invoke(Unknown Source)
        at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25)
        at java.lang.reflect.Method.invoke(Method.java:585)
        at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:719)
        at java.lang.Thread.run(Thread.java:595)
    Caused by: com.cisco.nm.xms.xdi.ags.system.CollectionFailed: java.lang.StringIndexOutOfBoundsException: String index out of range: 2
        at com.cisco.nm.xms.xdi.pkgs.LibInventory.EnergyWise_HelperMethods.getDeviceEnergyWise(EnergyWise_HelperMethods.java:72)
        at com.cisco.nm.xms.xdi.pkgs.SharedInventoryCatIOS.EnergyWiseAGI_ENERGYWISE_Mib.g$eval(EnergyWiseAGI_ENERGYWISE_Mib.java:51)
        at com.cisco.nm.xms.xdi.ags.EnergyWiseAGI.g$eval(EnergyWiseAGI.java:21)
        at com.cisco.nm.xms.xdi.SdiEngine.initAndEvalAGIs(SdiEngine.java:383)
        at com.cisco.nm.xms.xdi.SdiEngine.request(SdiEngine.java:309)
        at com.cisco.nm.xms.xdi.SdiEngine.getDevRepr(SdiEngine.java:302)
        at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:539)
        ... 1 more
    [ Fri Mar 18  16:28:24 EDT 2011 ],ERROR,[Thread-17],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,761, Collection failed for the device : 63
    com.cisco.nm.xms.xdi.ags.system.CollectionFailed: java.lang.StringIndexOutOfBoundsException: String index out of range: 2
    Kindly check if the your device is running the required IOS on the device as per the device supported list :-
    http://www.cisco.com/en/US/docs/net_mgmt/ciscoworks_lan_management_solution/3.2/device_support/table/lms32sdt.html
    There are two 3925 listed with different versions :-
    Cisco 3925 Integrated Services Router   --> 1.3.6.1.4.1.9.1.1042  --> 15.0(1)M [RME]. if this is your device then upgrade to
    3925 to 150-1.M2
    and
    Cisco 3925E Integrated Services Router  --> 1.3.6.1.4.1.9.1.1144 --> 15.1(1)T
    Thanks,
    Gaganjeet
    If this post answers your question, please click the "Correct Answer" button

  • RME 4.31 inventory collection failed on 122-33SXI3

    Hi
    I have the same issue with IOS 122-33 SXI3  running on 6513.
    RME unable to collect the inventory details eventhough updated to LMS 3.2 .
    RME version : 4.3.1
    Is any workaround to solve this issue on LMS 3.2
    Regards
    Dileep

    Hi Clarke,
    I am also facing the similar issue with IOS 12.2(33) SXI1, the Core Switches are in VSS mode. Inventiry collection shows failed for these devices. I am using LMS 3.1 with the following submodule versions:
    Name
    Version
    License Status
    Size
    CiscoWorks Common Services
    3.2.0
    Licensed
    Not applicable
    Campus Manager
    5.1.0
    Purchased
    5000
    CiscoView
    6.1.8
    Licensed
    Not applicable
    CiscoWorks Assistant
    1.1.0
    Licensed
    Not applicable
    Device Fault Manager
    3.1.0
    Purchased
    5000
    Internetwork Performance Monitor
    4.1.0
    Purchased
    5000
    Integration Utility
    1.8.0
    Licensed
    Not applicable
    LMS Portal
    1.1.0
    Licensed
    Not applicable
    Resource Manager Essentials
    4.2.0
    Purchased
    5000

  • RME 4.3.1 - No inventory collection of some 65xx devices

    Hi all,
    my problem is, that LMS3.2 with RME 4.3.1 does not make an inventory of some 65xx devices. What I've tried so far to correct this problem:
    # read the other incidents regarding this problem
    # increased the RME device attribute "SNMP timeout" from 2s to 10s -> no success
    # increased SNMP timeout for one device (192.168.90.7) from 10 to 20s and the retries from 2 to 3 -> no success
    What I've observed:
    # no credential problem (I can backup the configs)
    # no SNMP problem (I can snmpwalk through the device)
    # Inventory collection takes always only app. 10s until the above error unless I've increased SNMP timeout and retries
    # IC_Server.log generates always following error:
    [ Tue Dec 15  12:22:59 CET 2009 ],ERROR,[Thread-21],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,729,Exception for device 192.168.90.7 is
    java.lang.reflect.InvocationTargetException
    at sun.reflect.GeneratedMethodAccessor12.invoke(Unknown Source)
    at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25)
    at java.lang.reflect.Method.invoke(Method.java:585)
    at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:719)
    at java.lang.Thread.run(Thread.java:595)
    Caused by: java.lang.NumberFormatException: EPLOYMENT RELEASE SOFTWARE (fc1)
    TAC Support: http://www.cisco.com/tac
    Seems if RME has a problem with this special IOS version.
    Enclosed you will find the complete IC_Server.log and the screenshot from the inventory collection of 192.168.90.7.
    Thank you in advance for help.
    Kind regards
    Alfred Brunner

    This is CSCtb16925.  A patch is available from TAC to correct the problem.

  • Inventory collection fails for ACE module (RME 4.3.1)

    I am trying to collect the inventory and ultimately the configurations for my ace modules.  When i try to do an inventory collection I get the error
    Device sensed, but collection failed
    Anybody have any ideas?
    Chris

    Post your IC_Server.log.
    Please support CSC Helps Haiti
    https://supportforums.cisco.com/docs/DOC-8895
    https://supportforums.cisco.com

  • LMS 3.2 Inventory collection - Job timeouts after ~5h, all devices "Not attempted"

    Hello All,
    We have a strange problem with LMS 3.2 regarding Inventory Collection.
    This problem started immediatelly after the LMS installation/upgrade (LMS 3.2 was installed on a new server, and LMS 2.6 database migrated to it).
    All Jobs finish as failed, with all devices "not attempted".
    Job hangs for a five and a half hours and then reports failed status.
    The symptoms are the same for scheduled jobs and manually created jobs.
    I also have opened a TAC case, but it seems that nothing relevant can be found in the IC_Server.log.
    Also, according to a packet capture, it seems that LMS does collect SNMP data from devices after a job is started...
    We tried to upgrade RME 4.3.0 to 4.3.1.
    One Job immediately after the upgrade was succesful (Inventory was collected for manually selected device), but the next day all Inventory Jobs were failing again with the same symptoms...
    Does anyone have a sugestion where to look for a problem trace?
    Thanks in advance!
    Ragards,
    Jasmina

    Hi Jasmina ,
    Please chech the Existing MDF pacakge :
    go to common service > software center > device update >>> check the checkbox for Cisco works common service   and click on check for updates
    --if there is an Update , please upgarde the MDF version..
    --Similarly look for any Available Device Pacakges update for RME , if there are Upgarde all the Device Pacakages ....
    --After all of the above Task is done , Now re-run the Job and it still fails then share the IC_server.log  again..
    Thanks--
    Afroj

Maybe you are looking for

  • Unable to create datawarehouse tables using DAC client

    Hi, We are facing error while creating data warehouse tables in DAC Client. Please find the below mentioned error message ===================================== STD OUTPUT ===================================== CREATING SIEBEL DATABASE OBJECTS F:\DAC\b

  • Sony hvr-a1u connection to macbook

    Has anyone actually connect it up via firewire? I have trial and errored it to death to get it to connect. Anyone have the settings of the camera to help me out? Thanks Thom

  • E-mail is continuously hacked

    I have written on this fourm before about a issue I am having with mail.  I currently use yahoo as an e--mail account.  I have heard 2 different stories on the news concerning this issue. 1. There is a security breach with apple computers allowing pa

  • My iPod will NOT charge anymore while it's turned on

    My iPod will NOT charge anymore while it's turned on, I have to plug it in then shut it off for it to charge. And when I connect it to the computer [Or any computer] It Says it cannot recognize the device..I've tried EVERYTHING to fix this...and I do

  • Can you take a snapshot or picture from IMovies?

    Can you take a snapshot or picture from IMOVIES? On my PC I simply paused the video and hit something that said snapshot and it was done. I am struggling a little bit with IMOVIES as I have never had APPLE before. Like it, but am new to it.