Dear All,
I want to create one role in which,I would like to give access to iw52
Also in this He should be able to create only Y1 and Y3 Notification.
One more thing is there any stanard role for all abap transaction.
I want to give this role as well to user
Thanks
MK..
Edited by: Julius Bussche on Jun 30, 2009 2:18 PM
Subject title changed to a more meaningfull one
Hi,
For IW52 for restriction in Notification please restrict it via auth object I_QMEL and I_VORG_MEL authorization objects. Please check and let us know if any issue.
For ABAP related standard SAP roles please look into the following:
SAP_BC_DWB_ABAPDEVELOPER ABAP Developers
SAP_XI_ADMINISTRATOR_ABAP Exchange Infrastructure: Administration Tasks
SAP_XI_BPE_ADMINISTRATOR_ABAP Exchange Infrastructure: BPE Administration Tasks
SAP_XI_BPE_CONFIGURATOR_ABAP Exchange Infrastructure: BPE Configuration Tasks
SAP_XI_BPE_MONITOR_ABAP Exchange Infrastructure: BPE Monitoring Tasks
SAP_XI_CONFIGURATOR_ABAP Exchange Infrastructure: Configuration Tasks
SAP_XI_CONTENT_ORGANIZER_ABAP Exchange Infrastructure: Organizational Tasks
SAP_XI_DEVELOPER_ABAP Exchange Infrastructure: Development and Design Tasks
SAP_XI_DISPLAY_USER_ABAP Exchange Infrastructure: Display
SAP_XI_MONITOR_ABAP Exchange Infrastructure: Monitoring Tasks
Check and let us know if any issue.
Regards
Aveek.
Similar Messages
-
No quality notification type has been defined for inspection type 89
Hi
When I am creating a manual inspection lot and want to create a quality notification it gives me this error "No quality notification type has been defined for inspection type 89" where do I assign the notifications to the inspection lot.???
I want to know where do I configure it??
Regards
SureshHi
Path for assigning the Qualtiy notification type to Qualtiy inspection type:
SPRO--> Qualtiy Mangement --> Qualtiy inspection --> Inspection lot creation -->
Maintain Inspection types.
Select the inspection type and goto details screen
You can find notification type field in the details.Give the value and Save.
Regards
Ramakrishna -
Pmcs- notification type deactivate from spro
hi pm gurus,
pl help in step by step path for deactivating the existing notification type for users.
thanks & regards
srihariHello Srihari,
depends on what you want to do. If you onyl want to ensure, that no new notifications with these notification types can be created, you should change the authorizations of the users. We've made the same for PM order types, and it works very well (creation of new orders with this type is impossible - already existing orders can be displayed w/o problems). As far as I rememeber, you'll run into problems, when you delete the customizing settings for already used notification types, when you try to access old notifications of this type.
Best regards
Stephan -
QM01 - Add new fields under SUBJECTS tab for notification type Q2
Hi Experts,
My requirement is to add 2 new fields to the create Quality Notification (QM01) Tcode under SUBJECTS tab for Notification type Q2.
I followed the following steps to achieve this :
[ SPRO -> Quality Mnanagement -> Quality Notifications -> Overview Quality Notification Types -> Then I selected Q2 and then selected dcreen structure for extended view -> Double clicked on 10\TAB02 ].
Now I arrived on the screen where we have to define the custom screen area and screen number.
But here in this case (Q2 notification type) all the 5 screen areas are already occupied , so where can I add my custom subscreen ??
Please refer to below screen shot for better understanding :
Please help ! Thanks in advance.
Kind Regards,
Ashish GoyalDear narendra bora
You can enter the more than two persons in but not on header screen. In operation you can make each seperate person responsible for each operation & that can be entered against each operation seperately. Also if operation is carried out by two person then also you can enter that in the form of split.
But it is not possible to enter two users in reported by field.
I hope this will resolve your issue.
Regards -
Transaction CLM1 not allowed for notification type QL
Hello guys,
one of our user try to open the transaction CLM1/CLM2/CLM3 he getting error message Transaction CLM1 not allowed for notification type QL
please any one give solution for this issue.
find the error screen shot for your reference.
Thanks
SuryaHello Surya,
Have you done Basic configuration for Claims processing in SAP Project System.
SPRO > Project System > Claim > Notification - Claim > Notification creation
Also check config for Settings for Claims.
Refer sap help for more details
SAP Library - Claim Management
Regards
Tushar -
Transaction QM03 not allowed for notification type MQ
HI Dears,
The following error is appearing when i want to view my notification created through defects
Transaction QM03 not allowed for notification type MQ
How to rectify it ?
AlagesanHi,
Check IQS3 transaction also....
Cheers,
Tushar -
Where to maintain notification type for txn IW21 in Plant maintanance
Hi Guys,
I like to maintain notification type for txn IW21 in Plant maintanance module. Where can I set this.
Cheers
S KumarHi,
Here is the path to maintain Notification Types.
Use Tcode SPRO
Plant Maintenance & Customer Service -> Maintenance & Service Processing -> Maintenance & Service Notifications -> Notification Creation -> Notification Types -> Define Notification Types
Then,Click "New Entries" button. Enter the Notification which you need & Save. -
Field selection for Notification type
Hi all,
I have a configured a notification type. I want to hide unwanted fields . I checked for " Set Field Selection for Notifications" in spro but i am not able to find these fields.
The Fields are under below tabs
location Data Tab
1.Room-ILOA-MSGRP
2.Plant section-ILOA-BEBER
3.Business Area-ILOA-GSBER
Please guide how to hide theses fields
Anil KumarHi Anil
I have not checked in SAP, butif the hiding of the fields in not possible through SPRO, then an easy way to hide fields is to use GUixT, which comes with std. SAP.
Regards
Manish Bansal -
User Exits for IW21 - Notification Type
Hi ,
I need to access User Exit related to IW21 , IW22 Transactions.
I require the user exit to customize process for a specific Notification type 'KS'.
User exit when a notificatrion Type is created & when it is modified.User Exits and Badi's For IW21 & IW22
BADI's
IQS0_STATUS_MAINTAIN Control of Changeability of User Status
IWO1_SUBSCREEN_0170 Display Additional Data on Object Screen 0170 PhysicalSample
IWOC_LIST_TUNING Performance Tuning for Lists in PM/CS
IWOC_OBJECTINFO_CHNG Changes to Data of Object Info Screen
NOTIF_AUTHORITY_01 Additional Authorization Checks for the Notification
WOC_FL_DETERMINE Determine Date for Determining Installation Loc. Equi.
USER EXITS
IWO10026 User check on setting status 'Do not perform'
IWO10027 User exit: Generate user-defined settlement rule
IWOC0001 Create PM/SM notification: Determine reference object
IWOC0002 PM/SM notification: Check whether status change is allowed
IWOC0003 PM/SM authorization check of ref. object and planner group
IWOC0004 Change single-level list editing PM/QM/SM ALV settings -
Screen Structure for Extended View" in "Overview of Notification Type"
Dear Members,
When I am using the function "Screen Structure for Extended View" in "Overview of Notification Type" in SPRO, I am not able to make any changes to "Tab Page Allocation" and areas under "Screen Area" What should i do to overcome this.
Thanks & RegardsHi,
The "Tab Page Allocation" setting determines how many sub-screens can be added to the tab. It is therefore not possible to change this field for some tabs which are designed to be single screen only. Example - 10\TAB10 (items), 10\TAB11 (tasks).
Should be changeable on tabs that allow multiple subscreens. Exampel - 10\TAB02 (Additional data).
-Paul -
Sales order creation is not possible for this notification type
Hello,
I want to create Sales Order through following menu:
Notification -- Functions - Sales order - CreateSelection of Order Type.
But I get following message:
'Sales order creation is not possible for this notification type'
The message says: No sales order type is assigned to the notification type.
But I did not find any such configuration where I can assign notification type to Sales Order document type.
Please help.
regardsTransaction OIM9
Menu Path
Customizing > Plant Maintenance and Customer Service > Maintenance and Service Processing > Maintenance and Service Notifications > Notification Creation > Notification Types > Define Order Types and Special Notification Parameters
Nomally CS (customer service) area use this function.
Regards
Luke -
Office 365 API, error: The token has invalid value 'roles' for the claim type ''
Hi guys,
I am trying to develop a Daemon / Server application using the new Office 365 APIs. I have added a new application to Azure Active Directory. I am using cURL + the app ID and secret to get a JWT token, this is the exact request:
curl -X POST https://login.windows.net/TENANT_KEY/oauth2/token \
-F redirect_uri=http://spreadyDaemon \
-F grant_type=client_credentials \
-F resource=https://outlook.office365.com/ \
-F client_id=XXXX \
-F client_secret=XXXX=
I get back a JWT however it has no scopes for access set here is the decoded JWT claims:
"ver": "1.0",
"aud": "https://outlook.office365.com/",
"iss": "https://sts.windows.net/TENANT_KEY/",
"oid": "17fa33ae-a0e9-4292-96ea-24ce8f11df21",
"idp": "https://sts.windows.net/TENANT_KEY/",
"appidacr": "1",
"exp": 1415986833,
"appid": "XXXX",
"tid": "e625eb3f-ef77-4c02-8010-c591d78b6c5f",
"iat": 1415982933,
"nbf": 1415982933,
"sub": "17fa33ae-a0e9-4292-96ea-24ce8f11df21"
Therefore when I do a request to the exchange API endpoint I get the following response:
HTTP/1.1 401 Unauthorized
Cache-Control: private
Server: Microsoft-IIS/8.0
request-id: d08d01a8-7213-4a13-a598-08362b4dfa70
Set-Cookie: ClientId=WDALDNO0CAIOOZDZWTA; expires=Sat, 14-Nov-2015 16:40:59 GMT; path=/; HttpOnly
X-CalculatedBETarget: am3pr01mb0662.eurprd01.prod.exchangelabs.com
x-ms-diagnostics: 2000001;reason="The token has invalid value 'roles' for the claim type ''.";error_category="invalid_token"
X-DiagInfo: AM3PR01MB0662
X-BEServer: AM3PR01MB0662
X-AspNet-Version: 4.0.30319
Set-Cookie: exchangecookie=6bf68da033684824af21af3b0cdea6e3; expires=Sat, 14-Nov-2015 16:40:59 GMT; path=/; HttpOnly
Set-Cookie: [email protected]=[email protected]4Wbno2ajNGQkZKWnI2QjJCZi9GckJKBzc/Oy9LOzdLOy6vOycXLz8XKxoGaio2PjZvPztGPjZCb0ZqHnJeekZiak56djNGckJI=; expires=Sun, 14-Dec-2014 16:40:59 GMT; path=/EWS; secure; HttpOnly
Set-Cookie: [email protected]=[email protected]4Wbno2ajNGQkZKWnI2QjJCZi9GckJKBzc/Oy9LOzdLOy6vOycXLz8XKxg==; expires=Sun, 14-Dec-2014 16:40:59 GMT; path=/EWS; secure; HttpOnly
X-Powered-By: ASP.NET
X-FEServer: DB4PR02CA0026
WWW-Authenticate: Bearer client_id="00000002-0000-0ff1-ce00-000000000000", trusted_issuers="00000001-0000-0000-c000-000000000000@*", authorization_uri="https://login.windows.net/common/oauth2/authorize", error="invalid_token",Basic Realm="",Basic Realm=""
Date: Fri, 14 Nov 2014 16:40:59 GMT
Content-Length: 0
I have asked a stack overflow question here: http://stackoverflow.com/questions/26950838/office-365-api-error-the-token-has-invalid-value-roles-for-the-claim-type
Any help on the matter will be hugely appreciated, thanks!Hi Manu,
To wrap this thread up; I have had an answer on stack overflow.
It appears that currently the grant type client_credentials is not supported, according to a comment on this blog post by Matthias' http://blogs.msdn.com/b/exchangedev/archive/2014/03/25/using-oauth2-to-access-calendar-contact-and-mail-api-in-exchange-online-in-office-365.aspx
"There is no way in the code flow to avoid username/password. We're working on a client credential flow for later this fall that will give you the functionality required to run background services. For this you will not need a username/password,
but the application will directly assert its identity and authenticate as itself."
Unfortunately I require client_credentials for a daemon process, Q4 is the scheduled release for support for this grant time.
Thanks for the help,
Nick -
Down time for N2 and N4 PM Notification type
Dear Experts,
We are not getting downtime duration for notification type N2 & N4 (as
it is available for N3 type) in report IW28/29.
Can we have downtime duration for N2 & N4 above reports?
Also effect field is required for N2 & N4 under system info tab as available for N3 type
Thanks in advance.Hi Don,
If N2 and N4 are the notificatin types defined in your system .. then check whether you have configured all the screen structures in simple and extended view as per spro >PM->maintenance and service processing -
>maintenance and service notificatins -
>overview of notification type
you should have screen area 035 & 040 .. for breakdown tick i guess ..
and while creating the notification in iw21 mark the breakdown tick ...
regrds
pushpa -
The QoS retains a notification for a limited period before deleting it. My question is, how long is this notification retain?
Can we have a lost problem if we havent wi-fi or 3g for a long time?
Thanks for your help!Problem Resolved - it is a font issue. Apparently Acrobat can't handle particular fonts and it is best to stick with a very small slection of fonts - Arial, Helvetica, Times Roman.
I haven't test a lot of fonts. If I do, I'll post there results here.
Bob -
IW21 Classification screen structurre for extended view for a notification type
Hi Guru's,
In Spro I added a screen structurre for extended view for a notification type
I have well the subscreen now but the labels are missing and the button classification doesn't work.
I guess that I should implement an user-exit or a badi.
Any idea please ?
Regards,
RahhaouiSee this picture This is from the same thread I referred earlier. I feel there should be better ways of learning these fundamentals about Module-pool programming, rahhaoui !
Best of luck
Jogeswara Rao K
Maybe you are looking for
-
ORA-06502:Numeric or value error ORA-01403: No data found --6502
Dear All I am using Forms 10g. I am calling a report from my form. but when i am calling then it is showing this error: ORA-06502:Numeric or value error ORA-01403: No data found --6502 My code is in Print Button : DECLARE repid REPORT_OBJECT; v_rep V
-
LinkSys e3000: Poor wireless signal
Hi, I have configured a new LinkSys e3000 as as wireless router in our house. I have left the configuration as default (only secured it and turned on the DHCP server). I have only turned on the 2,4 GHz network ( because the 5GH had an even shorter ra
-
Load Balancing help needed...
I've been asked to research/implement load balancing on our Java only NW2004s EP (Unix) installation. I've read the help files here, but not sure I understand what I'm supposed to do, if anything at this point. http://help.sap.com/saphelp_nw2004s/hel
-
why do I see the message "This apple ID has not yet been used in the itunes store"when I enter my password in app store or itunes?
-
I would just like to know what Duke Dollars are and what they do for me, can I make money with them, can I feed the poor with them?