ROS - SRM Vs, Vendor management -E-Sourcing

Hi all
How vendors are screened in e-Souricng in Vendor management arena. I learnt that e-sourcing too accept and manage vendors .
Supplier screening is very important in procurement busisness.
Is it like Registration of suppliers (ROS) in SRM?
Are after created a vendor in e-sourcing , will u push to ECC or SRM. How vendor data are sync with Backend systems like ECC /SRM.
really vendor data relate with accouting data will be stored in ECC. what about in e-sourcing.
since customer expect this functionality. ARe in e-sourcing can used for only Vendor management for large scale customers. for eg tomorrow DUN And BRADSHEET wanted to use Vendor management functionality via e-Sourcing. is it possible.
Any help is apprecited. I am Mostly interested  How vendors are selected / what are the main factors are considered to accept a vendor .
Thanks
Muthu

Hi Muthu
Check out this note
1313088  Integration of SAP E-Sourcing 5.0/5.1 and SAP ERP
on page 2 and 3
Replication of SAP E-Sourcing Supplier to SAP ERP Vendor
This scenario supports the replication of suppliers that have been created in SAP E-Sourcing
for a sourcing event. Suppliers can be replicated back to SAP ERP individually on an asneeded
basis with user intervention.
When transmitting supplier master data from SAP E-Sourcing to SAP ERP, only external
number assignment is supported. This means that SAP E-Sourcing determines the supplier
number that is assigned to the vendor when it is created in SAP ERP. This is possible via SAP
E-Sourcing configuration mechanisms.
Internal number assignment in SAP ERP is not supported in the current integration package.
This means that SAP E-Sourcing does not allow a supplier to be published to SAP ERP when
internal number assignment is used. An error message is displayed in this case.
Linking is possible only through a manual process (that is, you must create the vendor in SAP
ERP manually and then link it to the SAP E-Sourcing supplier manually).
Supplier changes cannot be replicated from SAP E-Sourcing back to SAP ERP. Only the initial
creation of the supplier is supported.
The following basic SAP ERP vendor fields are supported:
SAP E-Sourcing Supplier Fields SAP ERP Vendor Fields......
cheers
alex

Similar Messages

  • ERROR [IM002] [Microsoft][ODBC Driver Manager] Data source name not found and no default driver specified in windows server 2008 r2

    ERROR [IM002] [Microsoft][ODBC Driver Manager] Data source name not found and no default driver specified in windows server 2008 r2.I made a application in asp.net c#.I am using ODBC connection.When I deployed my application in windows server2008 r2.There
    is no Microsoft ODBC driver shown in ODBC Data source administrator.Then I go to the C:\Windows\SysWOW64 and open  Odbcad32.exe and add Microsoft ODBC2 driver for Oracle and when I run my application I got following error
    ERROR [IM002] [Microsoft][ODBC Driver Manager] Data source name not found and no default driver specified
    I am using follwoing string
     <connectionStrings>
    <add name="theconnetion" connectionString="DSN=abdb;UID=abc;PWD=xyz"/>
     </connectionStrings>
    Guide me What I do?

    Did you add a System DSN or a User DSN? If you added a User DSN from your own login, the asp.net application will not be able to use it unless its application Pool in IIS is configured to run under the same credentials that you used for creating
    the DSN. It's better if you add a System DSN.
    Also, be careful to ensure that you are using a 64 bit DSN, unless you configure the application to run in 32 bits. If the 64 bit application attempts to use the 32 bit driver you get the same error message "Data source name not found and no default
    driver specified". See this KB article:
    http://support.microsoft.com/kb/942976/en-us

  • How to select the vendor from the source list in the PO(me21n) screen ??

    Hi
    How to select the vendor from the source list in the PO(me21n) screen.
    Is there any Sources of Supply tab in the PO just like we have in the PR.
    I don't want a PO raised from a PR which has got the Vendor assigned to it already.
    Or the SAP doesnot provide the option of Source list/Assign source/Sources of Supply .....in the PO.
    Kindly reply

    There is not any facility available for Source Determination in PO. Only you can select the line item and click Menu Environment > Source List and view the list of sources available for the material but you can not chooss and assign. If you wan to assign the vendor then change the vendor already entered in PO and put the desired vendor.

  • SQL Server Reporting Services: ERROR [IM002] [Microsoft][ODBC Driver Manager] Data source name not found and no default driver specified

    Hey everyone, So I am trying to get a report onto the server, and in BIDS I kept getting a login screen repeating over and over when I tried to deploy my report, so I tried to upload the file at http://<servername>/Reports This worked, but then trying
    to run this report from http://<servername>/Reports did not work either because "An error has occurred during report processing. (rsProcessingAborted) Cannot create a connection to data source 'FTYDataSource'. (rsErrorOpeningConnection) For more information
    about this error navigate to the report server on the local server machine, or enable remote errors" Anyways I tried to add a New Data Source (which I would use in the report) at http://<servername>/Reports, type ODBC, with the connection string Dsn=blah_blahblah.
    I try to test the connection here and get the error ERROR [IM002] [Microsoft][ODBC Driver Manager] Data source name not found and no default driver specified This is really getting old fast, everything I try, a new error comes up. Granted I am new at this,
    but this still should not be this troublesome. Does anyone have any ideas on what could FINALLY allow me to just put a report out onto the server?!? THANK YOU in advance for ANY help.

    Hi,
    Please try setting the credentials of the datasource.
    1. Double click and open the datasource in your project.
    2. Click on the credentials tab, and click on option button 'Use this username and password'
    3. Enter the username and password to connect to the datasource
    4. Deploy or upload the datasource to the report server and try accessing the reports.
    Hope this helps.
    Please click "Mark as Answer" if this resolves your problem or "Vote as Helpful" if you find it helpful.
    BH

  • Need SRM BW Vendor Evaluation Report Names with format

    It would be really appreciable if someone can share the SRM BW Vendor Evaluation Report Names along with the format.
    Cheers,
    Sheetika

    Hi Sheeetika,
    please check here..
    http://help.sap.com/saphelp_nw70/helpdata/en/42/de4c7e2f842cede10000000a1553f7/content.htm
    hope this will help you.
    Thanks,
    vijay.

  • Linked Server [Microsoft][ODBC Driver Manager] Data source name not found and no default driver specified

    Hi  I have SQL2012 installed on my local machine and have also installed MySQL 5.6.23 installed with a test database.
    I also have my SQL connector installed and MYSQL ODBC Driver 3.51.   
    Which happily connects to the Mysqldb.
    The Datasource Name : mySQL conn
    TCP/IP Server : localhost and Port :3306
    User root
    with pwd
    On the SQL side I have used the following
    EXEC master.dbo.sp_addlinkedserver
      @server = N'MYSQLSRV',
      @srvproduct=N'mySQL conn',
      @provider=N'MSDASQL',
      @datasrc=N'mySQL conn'
    However when I try to selet using open query
    SELECT * FROM OPENQUERY ( [MYSQLSRV], 'SELECT * FROM students' )
    it comes back with
    OLE DB provider "MSDASQL" for linked server "MYSQLSRV" returned message "[Microsoft][ODBC Driver Manager] Data source name not found and no default driver specified".
    Msg 7303, Level 16, State 1, Line 1
    Cannot initialize the data source object of OLE DB provider "MSDASQL" for linked server "MYSQLSRV".
    I cant understand what I have done wrong .   Any help in this would be great as Ive hit a bit of a brick wall

    Hi Robert3975,
    In addition to other post, please also note the following things.
    1. If you use the 32-bit driver on a 64-bit machine, please run the 32bit version of "odbcad32.exe" by running "c:\Windows\SysWOW64\odbcad32.exe"
     from Start/Run menu and
    create your ODBC DSN. However, for the 64-bit driver, use c:\windows\system32\odbcad32.exe to create your ODBC DSN. For more details, please review this similar
    thread.
    2. Expand the folder Providers under Linked server directory in SSMS and go to properties of MSDASQL provider and configure it properly as described in this blog:
    Creating Linked server to MYSQL from SQL Server.
    Thanks,
    Lydia Zhang
    If you have any feedback on our support, please click
    here.
    Lydia Zhang
    TechNet Community Support

  • SRM - Catalog Content Management

    Hi SRM Masters
    Can any one could send me the config documentaion for SRM Catalog Content Management document and functionality(other than SRM260 and SRM270 both I have).
    and also SUS config documents and functionality.
    Regards
    Rajesh

    Hi,
    Check these links....
    http://www.sap.com/usa/solutions/businesssuite/srm/pdf/BWP_SID_Catalog_Content_Mgmt.pdf
    http://www.jhu.edu/hopkinsone/documents/SRMCatalogandContentManager_000.pdf
    Reward points if useful....
    Regards
    AK

  • Vendor Management / Tracking the Product or Material

    Hi Friends:
    Is it possible to follow up on Vendor Management. the case study is as under :
    In an organization, the customer has a problem with the product, & the organization offers Customer Service ( which may be mapped in CS Module), in-house repair & on site repair.
    There is a case wherein the engineer from the service provider side ( organization) is not able to solve the problem & due to technical or lack of spare part or any other reason, the product / or its part is sent back to VENDOR either fo the Replacement or REPAIR of the product, and the customer does not know where is the product or its part is neither the service engineer s know, And when customer makes a call to enquire about his product, no one in the company has the answer asto where the product is either with the service provider or at the VENDOR site.
    So, in order to track the product immediately... where can the same be tracked & which Module of ERP (R/3)? CS Module, MM Module or any other Module ?
    Kindly Suggest & advice.
    Regards, Pradeep

    Hi,
    As per your scenario, try these following steps:
    1. Create the Service Notification
    2. Create the Service Order based on notification
    3. Based on analysis, either operation can be done internally (PM01 Control Key) or externally (PM02 Control Key)
    4. PR would be generated for the External Operation
    5. Components may be issued based on that order for the External Operation
    So based on that document flow in notification, you can track the status of the service notification. Even you can define the tasks to be done for the service in the notification, so that, you can track that notification very well.
    Regards,
    Maheswaran.

  • SRM-SUS Vendor registration BSP enhancement.

    Hello Gurus,
    Need help on vendor registration screen enhancement on SRM SUS. Its BSP application. How to enhance the BSP application. I need to add almost 20-25 fields in the SRM-SUS Vendor registration process screen. How to achieve this.
    Appriciate for the immediate responce.
    Thanks,
    Ram

    Hello Veda,
    Do we have an option to edit a specific page form SUS application without the need to create a Z copy of the same. Say I want to provide a new field on SUS PO screen in standard SUS application.
    Does system requires an access key for editing this object at Page level or BSP application level ?
    I cannot check the same in my system as it asks for normal workbenc request to edit the object.
    If you are aware of this access key, please provide some details.
    Thanks,
    Mridula

  • Vendor Managed Inventory

    Hi All,
    Can any body help me by giving some useful links regarding Vendor Managed Inventory (VMI), from where can i get Best practice document related to VMI.
    regds,
    CB

    Hello,
    Following  SAP help link may help you;
    http://help.sap.com/bp_blv1600/V5600/BBLibrary/HTML/139_EN_IN.htm
    http://help.sap.com/erp2005_ehp_04/helpdata/en/c6/af3c415e5dde2be10000000a1550b0/content.htm
    http://help.sap.com/saphelp_scm70/helpdata/en/5c/3f9df8bbc34413809579fc5d18414e/content.htm
    BR,
    Tushar

  • Vendor Managed Consignment

    Hi All
    Can some send me a process flow diagram on Vendor Managed Consignment.
    Please include the following together with notes
    1. Goods Issue against a reservation
    2. checking of Consignment stock balances
    3. Back Order creation
    4. consignment physical inventory
    Vishnu

    Hi vishnu,
    Pl. find the link for PDF file http://help.sap.com/printdocu/core/Print46c/en/data/pdf/MMIM/MMIM_ST.pdf
    http://sap-img.com/sap-sd/consignment-sales-process-in-sap.htm
    http://www.easymarketplace.de/online-pdfs.php
    Regards
    hareesha

  • [unixODBC][Driver Manager]Data source name not found, and no default driver

    Hi,
    I'm running
    Red Hat Linux 5, MySQL and BOXI 3.1
    I try and schedule a report in the CMC and the report fails with the error
    A database error occured. The database error text is: {Driver Manager} Data source name not found, and no default driver specified. (WIS 10901)
    I've went through the steps in the Bus Obj's Documentation outlining how to install the unixODBC (though this doco was for R2 - I'm not certain whether this install is needed for 3.1).  
    Error WIS 10901 details
    Database error: . Contact your administrator or database supplier+
    for more information. (WIS 10901)
                  The database that provides the data to this document has generated an error.
    Cause
                  Details about the error are provided in the section of the message indicated
                  +by the field code: .
                  Contact your BusinessObjects administrator with the error message
    Action
                  information or consult the documentation provided by the supplier of the
                  database.
    Any pointers suggestions on how to set up correctly the unixODBC will be looked into.
    Thanks for taking the time to view this post.
    Cheers

    Hi again Aravind,
    I hope you're not beginning to wish you had never answered that first question from me since it seems as if I'm now backing up the truck with regard to the entire question. If I'm asking too much from you let me know I don't wanna overstep the line with repect to what should and shouln't be asked in these forums'
    anyway I looked in that env.sh script. It was huge (pity I can't attach the file, I've appended it but it makes these threads somewhat lengthy)
    DEFAULT_ODBCFILE="$BOBJEDIR"defaultodbc.ini
        export DEFAULT_ODBCFILE
        +ODBC_HOME="$odbc"+
        export ODBC_HOME
    also
      # setup the mysql env variables
        if [ -d "$BOBJEDIR"/mysql ]; then
                # mysql env variables
    set up the odbc symlink to work around:*
    The DataDirect SQL Server ODBC driver on UNIX will not function properly under a*
    locale other than "en_US" due to strong dependencies on their locale files.*
                MYSQL_UNIX_PORT="$BOBJEDIR"mysql/mysql.sock
                export MYSQL_UNIX_PORT
        We want to be able to source the config file multiple times.
    fi
    if [ -d "$BOBJEDIR"/tomcat ]; then
    set the JAVA_OPTS for tomcat
    I see what you were referring to earlier with
    if [ -d "$ODBC_HOME/locale" ]; then
          the javascript files are kept here
    The machine name
    The user name
    MYLOCALE=`locale | grep LC_MESSAGES | sed -e 's|LC_MESSAGES="||g' -e 's|"$||g'`The default registry
          if [ ! -d "$ODBC_HOME/locale/$MYLOCALE" ]; then
            ln -s "$ODBC_HOME/locale/en_US" "$ODBC_HOME/locale/$MYLOCALE"
          fi
        fi
    Again cheers for your help in this matter.
    #!/bin/sh
    BOBJEDIR="/home/eberwick/BO_3_1/bobje/"
    export BOBJEDIR
    BODIR="`dirname $BOBJEDIR`/"
    export BODIR
    DEFAULTFILE="$
    check for existence of u flag, if it is there, turn it off.
    Set a flag so we don't source the environment more than once
    webi config file
    ccm.config"
    if [ -f "$DEFAULTFILE" ]; then
        . "$DEFAULTFILE"
    fi
    . "${BOBJEDIR?}setup/modify_ko_locale.sh"
    SOFTWARE=`uname -s`
    OBJECT_MODEL=`grep Platform $BODIR/setup/ProductID.txt | awk '{print $4;}'`
    [ -z "$OBJECT_MODEL" ] && OBJECT_MODEL=32
    SOFTWAREPATH=`grep SoftwarePath $BODIR/setup/ProductID.txt | awk '{print $3;}'`
    U_FLAG=0
    if [ X"$SOFTWARE" = "XHP-UX" ]; then
    unset the LANG so that we don't get the localized version of 'unlimited' if the localized system messages are installed.
    raise the ulimits to max allowed
    undo that bug workaround from above
    figure out what architecture we're on
    now that we're localized, deal with unknown architecture
    we include English, as localization may have failed
    set the JDK variable
        if [ x`echo $- | grep "u"` != "x" ]; then
            set +u
            U_FLAG=1
        fi
    fi
    if [ x"$BOBJE_ENV_SOURCED" = x ]; then
        if [ -f "$setup/boconfig.cfg" ]; then
        HKEY_LOCAL_MACHINE="$setup/boconfig.cfg"
            export HKEY_LOCAL_MACHINE
        fi
        BOBJE_ENV_SOURCED="true"
        export BOBJE_ENV_SOURCED
        BOBJEVERSION="12.0"
        export BOBJEVERSION
        LANGWAS="$LANG"
        unset LANG
        LC_ALLWAS="$LC_ALL"
        unset LC_ALL
        ulimit -Sn `ulimit -Hn` # max file descriptors
        ulimit -S -c `ulimit -H -c` # max core file size
        ulimit -S -d `ulimit -H -d` # max data segment size
        ulimit -S -f `ulimit -H -f` # max file size
        ulimit -S -s `ulimit -H -s` # max stack
        ulimit -S -t `ulimit -H -t` # max CPU time
        LANG="$LANGWAS"; export LANG
        unset LANGWAS
        LC_ALL="$LC_ALLWAS"; export LC_ALL
        unset LC_ALLWAS
        case X"$SOFTWARE" in
            XLinux) SOFTWARELC="linux"; SHAREDLIBSUFFIX=".so"; CB1LIBSUFFIX="${SHAREDLIBSUFFIX?}.12.0"; CB1SYMLINKLIBSUFFIX="${SHAREDLIBSUFFIX?}.12" ;;
            XAIX)   SOFTWARELC="aix"; SHAREDLIBSUFFIX=".so"; CB1LIBSUFFIX=".12.0${SHAREDLIBSUFFIX?}"; CB1SYMLINKLIBSUFFIX=".12${SHAREDLIBSUFFIX?}";;
            XSunOS) SOFTWARELC="solaris"; SHAREDLIBSUFFIX=".so"; CB1LIBSUFFIX="${SHAREDLIBSUFFIX?}.12.0"; CB1SYMLINKLIBSUFFIX="${SHAREDLIBSUFFIX?}.12";;
            XHP-UX)
                    SOFTWARELC="hpux";
                    if [ "$SOFTWAREPATH" = "hpux_ia64" ]; then
                            SHAREDLIBSUFFIX=".so";
                    else
                            SHAREDLIBSUFFIX=".sl";
                    fi
                    CB1LIBSUFFIX="${SHAREDLIBSUFFIX?}.12.0";
                    CB1SYMLINKLIBSUFFIX="${SHAREDLIBSUFFIX?}.12";;
        esac
        export SOFTWAREPATH
        export SOFTWARE
        export SHAREDLIBSUFFIX
        export CB1LIBSUFFIX
        export CB1SYMLINKLIBSUFFIX
        if [ "$SOFTWAREPATH" = "" ]; then
            echo "$UNKNOWNPLATFORM (unknown platform): $SOFTWARE"
            exit 1
        fi
        if [ -d "$BOBJEDIR"/jdk ]; then
          JAVA_HOME="$jdk"
          export JAVA_HOME
        fi
          JAVA_OPTS="-d$OBJECT_MODEL -Dbobj.enterprise.home=$
    fi
    setting AAHOME here so when CAD starts the value is set
    enterprise120 -Djava.awt.headless=true -Djava.net.preferIPv4Stack=false"
          if [ "$SOFTWARE" = "AIX" -o "$SOFTWARE" = "SunOS" -o "$SOFTWARE" = "Linux" -o "$SOFTWARE" = "HP-UX" ]; then
            JAVA_OPTS="$JAVA_OPTS -Xmx1024m -XX:MaxPermSize=256m"
          fi
          export JAVA_OPTS
        if [ -d "$Dashboard_Analytics_120" ]; then
            AAHOME="$Dashboard_Analytics_120"
            export AAHOME
        fi
        WCSDIR="$enterprise120/$SOFTWAREPATH/wcs/"
        export WCSDIR
        WCSBINDIR="$bin/"
        export WCSBINDIR
        WCSCOMPONENTDIR="$components/"
        export WCSCOMPONENTDIR
        BINDIR="$enterprise120/$SOFTWAREPATH/"
        export BINDIR
        LIBDIR="$enterprise120/$SOFTWAREPATH/"
        export LIBDIR
        PLUGINDIR="$enterprise120/packages/"
        export PLUGINDIR
        PLUGINDIST="$enterprise120/$SOFTWAREPATH/plugins/"
        export PLUGINDIST
        LOGDIR="$append the new valuelogging/"
        export LOGDIR
        if [ x"$BOE_LOGGER_ENVIRONMENT" = x ]; then
            BOE_LOGGER_ENVIRONMENT="-loggingPath $LOGDIR"
        else
            BOE_LOGGER_ENVIRONMENT="$BOE_LOGGER_ENVIRONMENT -loggingPath $LOGDIR"
        fi
        export BOE_LOGGER_ENVIRONMENT
        SCRIPTDIR="$enterprise120/generic/"
        export SCRIPTDIR
        JAVASCRIPTDIR="$setup/jscripts/"
        export JAVASCRIPTDIR
        MACHINENAME=`uname -n`
        export MACHINENAME
        removeUTF8SpecificsForKorean
        STRIPPEDMACHINENAME=`hostname | sed -e 's/\..*//'`
        export STRIPPEDMACHINENAME
        if [ x"$BOBJEUSERNAME" = x ]; then
          BOBJEUSERNAME=`id | sed -e "s|).\$||" -e "s|^.(||" `
          export BOBJEUSERNAME
        fi
        restoreUTF8SpecificsForKorean
        DEFAULT_REGFILE="$BOBJEDIR"setup/.defaultreg
        export DEFAULT_REGFILE
        REGFILE="$BOBJEDIR"data/.bobj
        export REGFILE
        BOE_REGISTRYHOME="$REGFILE/registry"
        export BOE_REGISTRYHOME
        DEFAULT_ODBCFILE="$BOBJEDIR"defaultodbc.ini
        export DEFAULT_ODBCFILE
        ODBC_HOME="$odbc"
        export ODBC_HOME
    the PID file location
        PIDDIR="$BOBJEDIR"serverpids
        export PIDDIR
        SQLRULEDIRECTORY="$LIBDIR"
        export SQLRULEDIRECTORY
        PATH="$BINDIR:$crpe/xvfb:$PATH"
        export PATH
        CRPEPATH="$enterprise120/$SOFTWAREPATH/crpe/"
        export CRPEPATH
        MWHOME="$mw/"
        export MWHOME
        BOBJEXVFBPATH="$xvfb/"
        export BOBJEXVFBPATH
        MWUSER_DIRECTORY="$once the crpe is in, we should exit if this file doesn't exist.
    Uncomment this to turn off Xvfb security and allow connections from
    everyone. 
    MW_XVFB_AC="1"
    export MW_XVFB_AC
    Use a seperate .Xauthority file.  Comment out this line if you want
    to use the user's .Xauthority file for storing the Xvfb authentication
    tokens.
    registry/"
        export MWUSER_DIRECTORY
        MWRT_MODE="professional"
        export MWRT_MODE
        MWREGISTRY=":$MWUSER_DIRECTORY/hklm_$
    Mainwin can deadlock unless this is set
    Prevents Mainwin from popping up dialogs in some situations, causing a deadlock
    variables merged from RAS
    XVFB Manager
    Environment Variables:
          MW_XVFB_EXE         = Name of the Xvfb exe.
                                Default is 'Xvfb'.
          MW_XVFB_DAEMON      = Name of the XvfbDaemon exe.
                                Default is 'XvfbDaemon'.
          MW_XVFB_DAEMON_PORT = Port number that Xvfb Daemon will listen too.
                                Default is 5222.
          MW_XVFB_DAEMON_HOST = Host on which the XvfbDeamon is running.
                                Default is Local host.
          MW_XVFB_DAEMON_XVFB = Number of Xvfb to run.
                                Default is '5'.
          MW_XVFB_DAEMON_DISPLAY = Starting display number for Xvfb.
                                Default is '1'.
          MW_XVFB_DAEMON_PROFILE = Path to the Security Profile for Xvfb.
                                Default is 'SecurityProfile'.
          MW_XVFB_DAEMON_TRACE = Set to turn on tracing information.
                                Default is undefined.
          MW_XVFB_DAEMON_DIE  = Turn off the exit code if no more connections.
                                Default is undefined.
          MW_XVFB_FONT = Locations from which to load font
    By this symbol being defined, the checking for a current set display is disabled.
    Set to turn on tracing info when defined.  Default is undefined.
    MW_XVFB_DAEMON_TRACE=defined
    export MW_XVFB_DAEMON_TRACE
    RAS Home
    .bin"
        export MWREGISTRY
        MWCORE_PRIVATE_DATA="$MWUSER_DIRECTORY/core_data"
        export MWCORE_PRIVATE_DATA
        if [ -f "$MWHOME"setmwruntime ]; then
            . "$MWHOME"setmwruntime
        fi
        MWNT_OLE_DOCS=true
        export MWNT_OLE_DOCS
        MWPRINTER_DPI=600
        export MWPRINTER_DPI
        MWVISUAL_CLASS="TrueColor"
        export MWVISUAL_CLASS
        if [ "$SOFTWAREPATH" = "hpux_ia64" ]; then
            MWTHREAD_STACK="200000"
        else
            MWTHREAD_STACK="FA000"
        fi
        export MWTHREAD_STACK
        MWFONT_DIR_PATH="$fonts/"
        export MWFONT_DIR_PATH
        MW_XVFB_DAEMON_FONT="$misc/"
        export MW_XVFB_DAEMON_FONT
        XAUTHORITY="$xvfb/.Xauthority"
        export XAUTHORITY
        MWDEBUG_LEVEL=0
        export MWDEBUG_LEVEL
        MWINVISIBLE_DISPLAY=1
        export MWINVISIBLE_DISPLAY
       MWNO_SIGCHLD_IGNORE=1
       export MWNO_SIGCHLD_IGNORE
       MWLOOK=motif
       export MWLOOK
            MW_XVFB_DAEMON_PROFILE="$BOBJEXVFBPATH/SecurityPolicy"
            export MW_XVFB_DAEMON_PROFILE
            MW_XVFB_DAEMON_IGNORE_DISPLAY="true"
            export MW_XVFB_DAEMON_IGNORE_DISPLAY
            if [ "$SOFTWARE" = "HP-UX" ]; then
                MW_XVFB_DAEMON_XVFB=10
            else
                MW_XVFB_DAEMON_XVFB=5
            fi
            export MW_XVFB_DAEMON_XVFB
            MWNO_FILE_LOCKING=true
            export MWNO_FILE_LOCKING
            MWNO_SIGNAL_CATCHING=true
            export MWNO_SIGNAL_CATCHING
        RASHOME="$enterprise120/$SOFTWAREPATH/ras/"
        export RASHOME
        LIBRARYPATH="$LIBDIR:$WCSCOMPONENTDIR:$PLUGINDIST/auth/secEnterprise:$enterprise120/$SOFTWAREPATH/crpe:$:$PLUGINDIST/desktop/CrystalEnterprise.Report:$enterprise120/$SOFTWAREPATH/ras:$
    May optionally be set to MALLOCMULTIHEAP=heaps:n[,considersize]
    where n is scaled to the number of CPUs (usually 2x).
    Setting to MALLOCMULTIHEAP=1 enables system defaults.
    setting MALLOCMULTIHEAP to 'considersize' fixes an AIX memory leak and significantly reduces the memory footprint.
    env variable to fix the default cpu affinity
    env variable to fix dlopen/dlclose behaviour to be more like ELF-based systems
    aix thread stack overflow guarding : won't catch if overflow is more than 4k, but better than nothing
    aix specific ulimit changes
    unset the LANG so that we don't get the localized version of 'unlimited' if the localized system messages are installed.
    undo that bug workaround from above
    set the aix thread scope to system (1:1)
    better core naming for aix 5
    Check if memory windows is enabled in the kernal parameters
    We will support memory windows, either through the "BOE120_HP_MEMWIN_ID" environment variable,
    or through the "BusinessObjectsEnterprise120" memory window key in /etc/services.window
    Use memory windows if available on HP-UX.
    For both HPUX Itanium and PA-RISC
    Reduce the number of arenas from 8 (default) to 1 (min) which solves memory blowup issue.
    Enable the thread local cache to compensate.
    http://www.docs.hp.com/en/B2355-60130/malloc.3C.html
    mysql/lib"
        if [ "$SOFTWARE" = "AIX" ]; then
            LIBPATH="$LIBRARYPATH:$LIBPATH"
            export LIBPATH
            if [ x"$MALLOCMULTIHEAP" = x ]; then
                CRConfig env variable for DCP
                MALLOCMULTIHEAP="considersize"
                export MALLOCMULTIHEAP
            fi
            RT_GRQ=ON
            export RT_GRQ
            LDR_CNTRL=IGNOREUNLOAD
            export LDR_CNTRL
            AIXTHREAD_GUARDPAGES=1
            export AIXTHREAD_GUARDPAGES
            LANGWAS="$LANG"
            unset LANG
            LC_ALLWAS="$LC_ALL"
            unset LC_ALL
            ulimit -S -m `ulimit -H -m` # max memory
            LANG="$LANGWAS"; export LANG
            unset LANGWAS
            LC_ALL="$LC_ALLWAS"; export LC_ALL
            unset LC_ALLWAS
            AIXTHREAD_SCOPE="S"
            export AIXTHREAD_SCOPE
            Version=`uname -v`
            Release=`uname -r`
            if [ "$Version" -gt 4 ]; then
                CORE_NAMING=ON
                export CORE_NAMING
            fi
            AIXTHREAD_MUTEX_DEBUG=OFF
            export AIXTHREAD_MUTEX_DEBUG
            AIXTHREAD_COND_DEBUG=OFF
            export AIXTHREAD_COND_DEBUG
            AIXTHREAD_RWLOCK_DEBUG=OFF
            export AIXTHREAD_RWLOCK_DEBUG
        elif [ "$SOFTWARE" = "HP-UX" ]; then
            if [ "$SOFTWAREPATH" = "hpux_ia64" ]; then
                SHLIB_PATH="$LIBRARYPATH:$SHLIB_PATH:$JAVA_HOME/jre/lib/IA64W.0/server"
            else
                SHLIB_PATH="$LIBRARYPATH:$SHLIB_PATH:$JAVA_HOME/jre/lib/PA_RISC2.0/server"
            fi
            export SHLIB_PATH
            MAX_MEM_WINDOW=`/usr/sbin/kctune | grep max_mem_window | awk '{print $2}'`
            if [[ "$MAX_MEM_WINDOW" != "0" ]]; then
                if [[ "$BOE120_HP_MEMWIN_ID" = "" && -r "/etc/services.window" && -x "/usr/bin/getmemwindow" ]]; then
                  BOE120_HP_MEMWIN_ID="`/usr/bin/getmemwindow BusinessObjectsEnterprise120`"
                  export BOE120_HP_MEMWIN_ID
                fi
                if [[ -x "/usr/bin/setmemwindow" ]]; then
                    if [[ "$BOE120_HP_MEMWIN_ID" != "" ]]; then
                        CE_CMDLINE_PREFIX="/usr/bin/setmemwindow -f -i $BOE120_HP_MEMWIN_ID "
                    fi
                fi
                export CE_CMDLINE_PREFIX
            fi
            export MARENA_OPTS=1:8
            export MCACHE_OPTS=100:8:0
        elif [ "$SOFTWARE" = "Linux" ]; then
            LD_LIBRARY_PATH="$LIBRARYPATH:$perl/lib/5.8.0/i386-linux-thread-multi/CORE:$LD_LIBRARY_PATH"
            export LD_LIBRARY_PATH
        else
            LD_LIBRARY_PATH="$LIBRARYPATH:$LD_LIBRARY_PATH"
            export LD_LIBRARY_PATH
        fi
        CRCONFIGFILE="$java/CRConfig.xml"
        if [ -f "$CRCONFIGFILE" ]; then
          CRConfig11="$CRCONFIGFILE"   
          export CRConfig11
        fi
        if [ -d "$ODBC_HOME/locale" ]; then
    set up the odbc symlink to work around:
    The DataDirect SQL Server ODBC driver on UNIX will not function properly under a
    locale other than "en_US" due to strong dependencies on their locale files.
          MYLOCALE=`locale | grep LC_MESSAGES | sed -e 's|LC_MESSAGES="||g' -e 's|"$||g'`
          if [ ! -d "$ODBC_HOME/locale/$MYLOCALE" ]; then
            ln -s "$ODBC_HOME/locale/en_US" "$ODBC_HOME/locale/$MYLOCALE"
          fi
        fi
    This was originally called TMPDIR, but now MainWin supports MW_TMPDIR, so we export MW_TMPDIR
    ADAPT00506764 tracks the original issue with TMPDIR/Essbase Connectivity
    MySQL now sets its TMPDIR in mysqlstartup.sh
    set the tmp dir locally, if the value is not already set.
        if [ x"$MW_TMPDIR" = x ]; then
          if [ ! -d "$BOBJEDIR"/tmp ]; then
            mkdir -p "$BOBJEDIR"/tmp
          fi
          MW_TMPDIR="$BOBJEDIR"/tmp
          export MW_TMPDIR
        fi
    Comment this out to turn off custom Solaris memory allocator
        if [ "$SOFTWAREPATH" = "solaris_sparc" ]; then
            LD_PRELOAD="libhoard.so.1"
            export LD_PRELOAD
    Need to set up 64-bit specific library path so that 64-bit processes will
    preload the 64-bit version of the memory allocator, and not the 32-bit version
            LD_LIBRARY_PATH_64="$enterprise120/solaris_sparcv9"
            export LD_LIBRARY_PATH_64
        fi
    setup the mysql env variables
        if [ -d "$BOBJEDIR"/mysql ]; then
    mysql env variables
                MYSQL_UNIX_PORT="$BOBJEDIR"mysql/mysql.sock
                export MYSQL_UNIX_PORT
        fi
    call env.sh from sub-directories (presumably from add-on installs)
        for dir in "${BOBJEDIR?}/setup"/*
        do
            if [ -r "${dir?}/env.sh" ]; then
                . "${dir?}/env.sh"
            fi
        done
    fi
    if [ X"$SOFTWARE" = "XHP-UX" ]; then
    check for existence of u_flag, if it is, turn it back on.
        if [ "$U_FLAG" = 1 ]; then
            set -u
        fi
    fi

  • Notification from SRM to vendor, who wins the bid

    Hi Friends
    Could you tell me, how can I send the notification from SRM to vendor, who wins the bid?
    Now I can only send invitation to the bid invitation.

    We activated special WF for bids

  • Factory-class in data-sources.xml managed-data-source

    OracleAS_1\j2ee\home\config has
    data-sources.xml
    Using managed-data-source.
    For connection-pool, connection-factory factory-class If I use OracleDriver instead of OracleDataSource, what difference would it have? In terms of performance?
    Thanks.

    Oops, a case issue...
    class="oracle.jdbc.pool.Oracle[b]OCIConnectionPool"

  • Differ. VMI(Vendor Managed Inventory) and SMI(Supplier Managed Inventory)?

    Hi all~
    I'm beginner in SNC.
    SNC have SMI scenario. But I think SNC-SMI is same as MM-VMI scenario.
    SMI
    ======================================================
    http://www50.sap.com/businessmaps/1D59B26B277611D5B359000102ACA9A3.htm
    The SMI process is a supplier-driven replenishment and planning process, which is based on min/max stock balance levels, on current demand, in-transits and planned shipments.
    ======================================================
    VMI
    ======================================================
    [http://www50.sap.com/businessmaps/459B5C21A96411D3870B0000E820132C.htm|http://www50.sap.com/businessmaps/459B5C21A96411D3870B0000E820132C.htm]
    With vendor managed inventory scenarios, manufacturers can offer their customers a value added service by performing the replenishment planning task for their business partners.
    ======================================================
    Anyone can help to verify differ or same?
    Thank you.
    SKY.

    Hello ,
      To add to above two answers,in SNC supply chain is as follows.
    SUPPLIER -
    >       MANUFACTURE     -
    > CUSTOMER
    SNC as an aplication will be installed at Manufatcurer site.
    Now if Supplier is managing inventory for manufacturer than it is SMI.In this case supplier will login into SNC ( hosted at Manufatcuring site ) and manage inventory.
    If Manufacturer is managing inventory for CUSTOMER than it is VMI.
    Basically SMI and VMI are mirror image of each other.
    Hope it will help.
    Regadrs
    Rahul

Maybe you are looking for