Round off problem in unit of measurement

Dear Experts
We are in SAP 4.7 , we are having more than 12 plants using same client.
One of our plant requirement we were changed the UOM 'Nos' with 3 decimels allowed.So where ever we not useing decimel places we have to use UOM as 'EA' (each).This is dont have any decimel places.
Now we are in implementation project for our one more new plant in same client. But for them we are going to introduced Batch specific unit of measurement. Base unit of measurement is KG and Batch specific UOM is EA.
All sale material have both unit of measurement , inward or production posting in KG and we will create batch number. We will enter the coversion value of how many quantity per kg for each batch.This will be in 'EA'
While i'm doing transfer posting or consumption or sales for the material in UOM 'EA' , it is coming with 3 decimel places.
If the same UOM 'EA' in normal condition (without batch specific UOM) it is working correctly.It is getting roundoff correctly.
Please help me out on this.I need the consumption should not be decimel places for UOM 'EA'.
Suresh

Hi Senthilkumar SD,
You have not read the thread before posting.
It quite clearly states that the UOM EA already has NO DECIMAL PLACES.
Quote "<b>we have to use UOM as 'EA' (each).This is dont have any decimel places."</b>
It is good to see lots of people trying to help and so I am pleased to see you trying, but it really doesn't help if you haven't read the question before posting the answer.
Steve B

Similar Messages

  • Problem with Unit of measurement

    Hi,
    I am having problem with Unit of measurement with different languages.
    Eg:
    In SPRO, I am able to see the unit of measure T3 Description: (Trading unit).  in SAP 200 client .the logon language is EN(english).
    But if I logon into same client(200) with different language DE(german) version, I am not able to see the description in German, the description field is blank.
    Kindly give me a solution for this problem as it is very urgent.
    Thanks in advance.
    Regards,
    Shankar

    Hi Aishwarya,
    I can think of 2 possibilities:
    1. You need to verify passing the Target UoM with the ISO Code as well as the update flag in the 'X' structures.
    2. The material that you are trying to pass some UoM does not have the conversion maintained in the Material Master. (Base UoM --> Target UoM conversion in Material Master, contact Functional Consultant).
    Also, if you can verify by performing the action manually and check if the Sales Order is getting created manually with the Target UoM .
    Regards,
    Pranav.

  • Problem of unit of measurment in production system

    Hi Friends,
    I'm facing a peculiar problem of unit of measurement like error in all quantity and curreny fields in report output after transporting a query from quality system to production system but this query is generated from multiprovdier. what might be the problem.   
    Regards,
    Srinivas.

    Hi Dave,
    Thanks for ur reply. but to trace in monitor it is not showing any error message.
    My Mail ID is [email protected]  Please the send the document
    Regards,
    bharat

  • Conversion Problem in Unit of measure 1PAC=100,000 EA

    Hi Experts,
    I am facing the problem in conversion of Unit of Measures.
    If some material has the conversion unit when we order to Vendor.
    The Unit of measure is EA, the Order unit is PAC.
    The conversion is 1PAC=100,000 EA
    But the System is allowing as 1PAC=10,000 EA only and it is not allowing to enter 100,000 EA and throughing the error
    Entry too long (enter in the format __,___)
    Message no. 00089
    How can we increase the characters of the Unit of measure. Like this we have some 50 Materials, I need to increase the length of the conversion spaces. How to do it, Please guide me.
    rgds
    Swamy

    Hi
    you can check this out the denominator factor is Stored in structure - SMEINH - field UMREN.
    Best option is to maintain decimal place for the UOM , which is more easier to mainatin.
    Even if you go through the note the same is explained. Please read below for Too large numerators and denominators
    When 120000 CM3 = 0,2 tons (TO), you can no longer save numerator and denominator of conversion ratio 600000 CM3 = 1 TO as numerator and denominator may have maximally five digits.
    Here, you must either select a larger volume unit or a smaller unit of weight: With DM3 the conversion ratio would be 600 DM3 = 1 TO, with KG the conversion ratio would be 600 CM3 = 1 KG.
    Generally, the alternative units of measure and the base unit of measure should result in quantities that are in the same dimension since the conversion factors may not be larger than 99999/1 and not smaller than 1/99999.
    Thanks & Regards
    KK
    Edited by: Kishore Kumar Chiluka on Apr 22, 2008 8:25 AM

  • Pricing Record Problem (alternative Unit of Measure)

    I am facing a problem in Pricing i.e that the Price is mainly maintained in Base unit of measure(CRT) but the selling is both in Crates and Bottels and the bottels is alternate UOM and Crate is the main unit of measure 90 % sales in crates. but when i enter the qty in alternative uom i.e is bottel price is not calcuated propery
    Example
    1 crt 24 bt
    Price of one crate =216
    when i enter bottels as uom the price should be 9 but system is showing 9.07

    Hi
    Litres is the Base unit of measure and Bottles and Carats are Sales unit of Measure in Ur case and u have maintained wrong figures
    Please maintained in this fashion
    1) 1 bottle  =  x litres
    2) 1 carat  = y litres
    in this way when u enter the 1 carat in Sales order system will go here and take the price of  1 litre and then multiply by ( This conversion factor in ur case y units)
    so u will get price as 1*y rs .
    In pricing please check what condition record u have maintained . Generally condition records are maintained in Base unit of measure i.e the condition record will say 1litre cost Rs  11 .
    Hope this calrify .
    Please reward -

  • Currency Conversion Round-off problem

    Hello
    My customer is in import business.
    When a journal entry is made in Dollar it is converting into Indian Rupee (local currentcy), which is correct
    but it is not rounding off. Also user cannot change it mannualy to adjust the roundo-off figure
    Is there any solution to this
    Regards
    Indrajit

    Hello Indrajit,
    What is your rounding setting for currency?
    Thanks,
    Gordon

  • Problem in Unit of measure

    Dear Guru,
    There is a problem with one material
    One material on jan converion ( material master) should change
    1 to 7.369 to 1 to 6.39
    at the end of feb order is created for that material, Now po will take the old conversion
    at the time of R&D iam deleting the info record from Po, then it will take right conversion
    Please suggest me why it is happened
    Regards
    Kashyap Kumar

    1 to 7.369 to 1 to 6.39 is this convertion maintained info record.if yes ,after deleting inforecord system will pick convertion from material master.Check inforecord what convertion factor maintained.

  • Round off problem?

    A ColdFusion program is trying to store a value or 0.25 into a column of type decimal(11,6) of SQL Server table but 0.0000000 is getting stored. 0.50 is getting stored at 1.0000000. This started happenning after using cfqueryparam. Maxlength is 17.
    What am I doing wrong?

    Was using cf_sql_decimal. Numeric didn't workeither but float did.
    Why is this?
    Thank you very much.

  • Price per unit is getting round off to two decimal places.

    Hi Gurus,
    In the Billing output, the Price per unit is getting round off to two decimal places.
    How can we avoid this or allow 4 decimal places for such cases.
    In the same pricing procedure, we have two pricing condition types PR02 and ZR01.
    When PR02 is being used,it doesnt rounds off Price per unit.e.g .578888 = .578888
    But when ZR01 is being used the system rounds off price per unit.e.g.578888 = .58
    Please suggest where is the setting for it.
    Thanks
    Montee

    Hi,
    Which currency you are using? If its INR, then it will do only for 2 decimal places.
    The solution for ur problem can be ractified by changing the scales :
    Also check OSS 80183
    Thanks,
    Raja

  • Unit of measure in BOM

    Hi...
    I have one problem with unit of measure in BOM.
    We can maintain item quantity upto 3 decimal point.My problem is with one of material having consumption of  0.01042 for 1pc of header material.
    Due to constraint in maintining decimal point in BOM we maintained it as 0.011 & it leads to undesired result after BOM explosion.
    I know there is one way of going with base qty. of header to be changed.
    Suggest  other else?How to get out of this.....
    Regards
    Tushar

    Hi Brhamankar...Thanx for your valuable i/p.
    We have got solution to the said problem as below(Without increasing the base quantity of header)...
    1)Create new unit of measure say TP
    2)Maintain it as alternate unit of measure with conversion as 1000TP=1042PC in material master of that component
    3)Maintain the quantity in BOM as 0.01TP
    4)Make plan entry for header level say for 50000
    5)After MRP run , procurement proposal for component as 521PC(Previously it was 550PC because restriction of 3 decimal point, in BOM rounded with 0.01042 =0.011PC)
    6)After MFBF, material consumption is also found ok
    Regards
    Tushar

  • Decimal places for unit of measure

    Dear All ,
    If i change the Decimal Places for rounding in Customizing for Unit of measure ( CUNI tcode) for KG as 6 from 3 whether it will calculate with the 6 decimal places like 0.004756 ( earlier with 3 decimal places it will calculate any multiplication with 0.004 now i want the same with 0.004756 Kg )
    whether it will work ?
    and where it will impact

    Hi
    No it will not work like that. And it depend on the transaction where you enter that. In case of Purchase order quntity field it will be always with 2 decimal places because field MENGE has 2 decimal places only. If your system is already live then it is not advisible to do such changes.
    Regards
    Antony

  • Unit of measure - rounding off during creation of planned order

    Dear All,
    We have defined one material OIL in MM41 and its UoM is EA also we have put alternative UoM is L(liter).
    now we create BOM of semifinished material we use this oil as a component and enter its value in decimal points.
    e.g 0.375 EA
    During planned order creation or REM backflush system convert this quantity to 1 EA ,WE dont want this automatic conversion .
    We have uploaded all master data in production and now it is very difficult to change all BOM
    So what is the solution of this that system can not convert qty (rounding off).EA
    Kindly reply
    Sunil

    Hi Sunil,
    IN CUNI Transaction Field Decimal Places is for displaying the decimals,there is a decimal place Rounding off field below,there try to maintain 3 decimals and check whether it is working.
    One more thing is Unit EA will be used always as non decimal unit,But i dont know in your buisness how for unit EA there is a decimal qty
    Edited by: Girish  Adaviswamy on Mar 2, 2010 10:59 AM

  • Rounding off unit of measurement

    Hi Experts,
    IWe are currently implementing ECC 600 for one of our client.
    Most of there products are items with unit of measure as Each (EA).
    Each unit is used for parts and hence it should not allow any decimal places like 1.4, 0.5, etc if the unit is EA.
    But in the standard SAP system available this check is not there and it allows to create PR, PO, GR, etc for such quantities. Allowing such unit of measure can cause problem later on.
    We need to block decimal place to be allowed for EA but could not find any settings for restricting this in Config (t.code CUNI). The field for decimal places is already blank and we have made no changes in the standard unit of measures.
    Kindly suggest how to achieve this, is there any setting we are missing?, is it that it is a bug in SAP and a note is released for the same?, if none of this than any work around or exits available.
    GANESHA
    Edited by: ganesh_pall on Nov 10, 2011 8:18 AM

    if your EA would be physically really an EA then the user would post any fractions.
    I personally feel that you have just used a wrong unit.
    a Wheel would for example have the unit EA, even it is technically possible to post with decimals, no user would really do it as it does not make any sense.
    but if you have a drum with 200 kg of a material, then you better use KG as base unit in case user remove the content from the drum partially.
    Technically SAP will always post with 3 decimals in inventory managment. you can hide the decimals from beeing displayed with settings in CUNI, but you cannot really restrict it.
    Better educate your users and talk to the guys who have done the movement which caused decimals to get knowledge why they have done it this way.

  • Alternate unit of measure should show in round off figures

    hi, in my material master, i have defined that 1 PAL (pallet)= 25kg.
    where base unit is kg and PAL is the alternate unit of measure.
    now in mmbe, if i view the report in "pal", the system shows in decimal values.
    i selected "Decimal Places as per unit" while running mmbe
    and in CUNI, I entered 0 in front of "decimal places" and "0" in front of "Decimal pl. rounding" but no luck. can any expert help me out plz.
    thanks

    can any1 plz tell me what is the purpose of "Decimal pl. rounding" in CUNI???
    i beleive proper use of this field could solve my issue.
    chakrapani thanks for ur input.

  • Valuation of characteristics for unit of measure "" causes rounding diff

    Dear gurus,
    I am facing a problem on Goods Issue and Transfer Posting. My Material is maintained with Batch Specific Unit of Measure.
    Base Unit = Kg ,and Batch specific unit of Measure = BAL(Bales).
    My unit of Issue = BAL. For every bale at the the time of GR, i m storing the wieght of the Bales in the system. Now at the time of Issue and transfer posting, system is giving the following error message:
    "Valuation of characteristic for unit of measure BAL causes rounding diff"
    In unit = KG, Decimal places = 7, Decimal places rounding = 7
    In Unit = BAL, decimal places = 3, Decimal places rounding = 3.
    Kindly help me guys...
    Thanks

    Dear Johi,
    See SAP NOTE 147489 - Error XU033 in goods movement with active ingredient. If you doesn't need to check rounding errors:
    "For this use the following path: Logistics -> General -> Batch Management -> Define System Message Attributes (Transaction OCHS)."
    Edit the system message XU03 to no errors.
    Regards

Maybe you are looking for