RS232 serial port or 98SE on M105S3041

I need RS232 to communicate with my CNC mill.
I purchased and installed a PCMCIA Serial I/O card but I can't make a serial mouse work. Running XPsp3. Do I have to disable the touchpad? I expected it would work like my M645S4070: plug in a USB mouse, turn off the touchpad, and then the USB mouse is the sole active mouse.
I installed 98SE on the same machine (M105S3041). 512mb RAM. The MS flag banner comes up, and that's as far as it'll go. Anything else I need to do?
Solved!
Go to Solution.

Yes, M645-S4070 is replacement for the M105, as WinXp is no longer supported. I took screenshots on the M105, and sent them to a flash drive to transfer to M645. When I asked to Safely Remove Hardware, I see that the flashdrive is there, and
"CH352 =>PCI SERIAL&&PARALLEL" is also listed.
You say
In Device Manager, double-click the device to open Properties. On the Details tab what does it have for Hardware Ids? Copy the longest line. It looks something like this.
I reply
The longest line is
PCIWEN_104C&DEV_8039&SUBSYS_FF001179&REV_00
Attachments:
Safely remove hardware.jpg ‏71 KB
Device Manager.jpg ‏81 KB

Similar Messages

  • RS232 Serial Port - LEDs

    Hi,
    I have some experience with Java, though not with any direct hardware communication.
    Can anyone help me make a simple program which will allow me to control a couple (or more) of LEDs?
    Any advice much appreciated.
    (I get the impression so far that this is very doable, and that I need CommAPI).
    Thanks in advance,
    J

    presuming the device with the LEDs has a serial connection to your PC, then yes, you'd need to get the Comm API. Then you connect to the device thru it. After that, it's entirely a matter of what the command protocol is that the device expects to receive.

  • VISA unable to communicate with or see RS232 serial com port

     I have a Dell Optiplex GX260 which has recently had Windows XP (Service Pack 2) re-installed on it.  National Instruments VISA is unable to communicate with the single RS232 serial com port on the computer.  Neither the "VISA Resource Name" control in LabVIEW 8.5 nor the "Measurement and Automation Explorer" can see the serial port.  Refreshing the list does not help.  "HyperTerminal"is able to both see and communicate with instruments connected to the serial port.  In Windows "Device Manager, the serialport appear in the list of hardware without any warnings.
    Can anyone please help with suggestions as to how I may be able to get VISA in LabVIEW to 8.5 to see and communicate with the serial port?
    System Details:
    Dell Optiplex GX260 (One RS232 serial port)
    Windows XP Home Edition Service Pack 2
    LabVIEW 8.5
    Solved!
    Go to Solution.

    AKA_TG wrote:
    Just passing by but I gotta say
    Guyts who answer like that do really irritate me
    Someone oughta apologize to the porr guy trying to get some help here.
    Go ahead and put me on your ignore list please!
    First, there is a plethora of messages on this forum and a plethora of information in the NI KnowledgeBase. If someone doesn't make the simple effort to take 5 minutes to perform a search what does that say? The issue being raised has come up, literally, dozens of times. Do you like answering the same question over and over and over and over and over again?
    Second, my feelings are not unique. You will find that the irritation of people not bothering to do a simple search is shared by most of the regulars here. Why do you think search engines are available? Just so that ads can be sold?
    Third, posting the SAME question in multiple threads is self-defeating. People who try to answer don't know what's already been suggested, and end up wasting their time as well as the poster's time in providing the SAME answer and/or suggestions that were provided in the other thread. 
    Fourth, simple forum netiquette. In both threads the poster essentially hijacked someone else's thread. This is frowned upon in just about every forum that I've ever seen.

  • The "VISA Configure Serial Port" VI will only run at 9600 Baud

    I have written a Serial Port monitor "RS232 RW.vi"  that works for the most part. The problem is that it will not respond to alternate port configuration settings.... For instance: the default RS232 Serial port configuration is:
    (COM1,9600 baud,8 data bits,1 Stop bit, None no parity)
    As a test, I am using a Null Modem Cable to connect From my LabView Com1 port to another PC running RealTerm Serial Port Monitor.. Using my newly designed "RS232 RW.vi"  With port settings of (COM1,9600 baud,8 data bits,1 Stop bit, None no parity),  I can send and receive data back and forth all day long no problems....
    However, if I configure the "RS232 RW.vi"  port to any other configuration, such as (COM1,2400 baud ,7 data bits,1 stop bit, Odd parity).. It will not take the expected chances and continues to operate @ 9600 baud etc.
    I then changed the "RS232 RW.vi"  default settings to (2400,7,1,Odd)
    it still refuses to deviate from (COM1, 9600,8,1,None...)
    I also went into the Win XP  Device Manager on the LabView system and manually configured Com1 to 2400,7,1,Odd  
    and still,.... the "RS232 RW.vi"  will only operate @ 9600,8,1,None
    Can anyone else test drive my VI and see if they have the same problem of not being able to see new changes in the Port configuration settings ..other than (COM1, 9600,8,1,None...).... ?
    FYI.. Unfortunately my LabView is running on Version 6.0 so you may need to up-convert the attached vi
    Solved!
    Go to Solution.
    Attachments:
    RS232 RW.vi ‏102 KB

    Instead of just appreciating the comments, you need to implement them.
    Having the VISA close inside the loop is definitely the problem.  And Crossrulz is 100% correct about the problem being that the serial port gets reset to the default baud rate after closing the port.  Here is the proof.
    Note that while you may have set the port settings manually in device manager, those settings are revised by the VISA driver.  If you look in Measurement and Automation Explorer under Devices and Interfaces >> Serial and Parallel, you'll see the default settings that the VISA driver uses.  If you change the setting there, your program will work the way you want.  But that is not the correct fix.  The correct fix is to get the VISA close out of the while loop.
    The port settings are established in this order.
    1.  By the Windows device drivers.
    2.  By the VISA driver as established in MAX.  Since you are useing VISA, these settings will automatically override #1.
    3.  By the port settings you set programmatically in your LabVIEW program.
    Attachments:
    Example_VI.png ‏18 KB

  • Multiple serial ports reading from a shared USB port

    I have a program that reads from 4 flow controllers, which send data through RS232 serial ports. Because the computer is located pretty far away, the vendor suggested to use an Edgeport box to convert RS232 to USB, then convert to ethernet port using a SuperBooster converter. The signal travels long distance in ethernet cable to the computer and get converted back to USB, then to the computer. In MAX, I was able to see 8 com ports from the Edgeport box, and I was able to communicate with my flow controllers.
    The problem is, it will give me some error message occasionally. Sometime it's a VISA Read error, sometime it's a VISA framing error. Could this be caused by the way the signal is transmitted?
    In the program I have four parallel WHILE loops that constantly do READ and WRITE to the 4 flow controllers. Could this be causing the errors? If so, what is the best strategy to design this program?
    Thanks

    I agree with Mike, you will need an error handling strategy that accounts for these errors.  And retries the communications.  This can be a little tricky, but very doable.  I believe some sort of statemachine approach will work best for this. 
    As for your heated probe.  I would make some sort of hardware interlock that will shut it down in case of a coolant failure.  NEVER, EVER trust the computer to be running where safety is concerned, either for personal or hardware.  There are plenty of ICs that can monitor temperature, and have warning, and alarm outputs!  Another option is some sort of watchdog on the communications bus for the coolant control, but I think this is a bit more tricky. 
    Paul <--Always Learning!!!
    sense and simplicity.
    Browse my sample VIs?

  • Error 37 using serial port with an executable file

    Hi all,
    I have developed a VI that controls a setellite receiver using RS232
    serial port (LabVIEW 5.1.1).
    The VI program run properly, but when I compile it and try to run the
    executable file I receive an "Error 37, Device not found" error message.
    I have already put serpdrv and my_file.ini files in the same directory
    of my executable program my_file.exe, but I have not been able to solve
    the problem.
    Any help greatly appreciated.
    Regards
    Antonio
    Sent via Deja.com http://www.deja.com/
    Before you buy.

    [email protected] wrote:
    >
    > Hi all,
    > I have developed a VI that controls a setellite receiver using RS232
    > serial port (LabVIEW 5.1.1).
    > The VI program run properly, but when I compile it and try to run the
    > executable file I receive an "Error 37, Device not found" error message.
    > I have already put serpdrv and my_file.ini files in the same directory
    > of my executable program my_file.exe, but I have not been able to solve
    > the problem.
    > Any help greatly appreciated.
    >
    > Regards
    >
    > Antonio
    >
    > Sent via Deja.com http://www.deja.com/
    > Before you buy.
    Maybe you used the serpdrv from an older version of LV
    Regards, Roland
    Roland Lampka - Nortel Dasa - ESN 565-7257 - FAX 8160

  • Warning 1073676424 from VISA Set I/O Buffer Size.vi on a serial port

    I am porting an application from LabVIEW 6.1 on Windows to LabVIEW 7 on OS X (Mac). It was very painless except some GUI modifications.
    The application involves 30 KB data from a instrument through a RS232 serial port. I found the application misses data whenever the computer is busy. The problem came down to the unchanged buffer size.
    Attempt to change the buffer size of a serial port with "VISA Set I/O Buffer Size.vi" fails with a warning of 1073676424 (The specified I/O buffer is not supported). Even the example vi from NI web site "Advanced _Serial_Write_and_Read.vi" has the same warning.
    I wonder what I am missing.

    Under the hood VISA is using the POSIX serial interface for Mac OS X (same as for Linux and Solaris). This interface does not support changing the buffer size. Hence, the buffer size is fixed to the internal OS buffer size. The only thing that changing the buffer size will do (for the out buffer) is to have VISA not flush the data after every write. This is a limitation in the serial API for Mac OS X. Therefore, VISA reports a warning.

  • Control a generator with a control volage by serial port RS232

    Hello everybody,
    I would like to control a generator thanks to a control voltage. This last one would be sent to a switch wich turns on the generator.
    To do that, I want to link the switch and the computer with a serial port RS232 by using NI-USN 232 cable.
    I made some research on this subject and I am only a beginner on LabView but I would like to use one (or several) pin which will send 5V in voltage when I want.
    Is that possible? Is there another way to make it?
    Thanks in advance.

    Thank you for your answer.
    Maybe, I didn't explain myself correctly. 
    For example, on the Raspberry Pi, you can control a card by sending 3,3V signal with RS232 port (I made it last year so it makes a sense).
    What I want to do here is to control an electronic card that turns on my generator after. I don't have enough to buy a generator controlled unless you know one not very expensive.

  • Interfacing of RS232 serial devices through USB ports within LabVIEW 6.1 and Windows 2000 Pro?

    I have a data acqusition requirement of using 5 RS232 devices, but the motherboard i use only has two serial ports. However, it does have 4 USB ports. Does anyone know if it is possible to use these USB ports to input data from an RS232 device through a serial to USB converter?
    Does LabVIEW 6.1 support this under Windows 2000 Pro?
    Thanks in advance,
    Fraser

    Hi Fraser,
    I just moved an app to a new laptop and had to use a USB to serial comm adapter. At first try the app did not find the comm port.
    After sleeping on it, we downlaoded the most up-to-date driver for the device and upgraded VISA to the latest and gretest version.
    Everything worked fine after that.
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • Thinkpad with serial port (RS232)

    For my job I need a laptop with a serial (RS232) port.
    I have the choice of the following laptops: Lenovo Thinkpad X230, X230T, T430, T530, W530.
    Neither of them have a serial port, right?
    I saw some mention of an adapter for the ultrabay slim bay, that would support an RS232 adapter.
    Does that work for all the above mentioned models?
    And if so, would the RS232 port work in the same way as the regular one? I need to program e.g. an Agilent datalogger with Labview to measure and recieve the measured data through the serial port.
    Kind regards,
    Rachel.

    thare are two ways :
    1. you can buy a usb to seial cable converter.
    2. if your laptop have a Docking Station. there is a serial port in the Docking station.  Put your laptop on the Docking station, the windows system will automatically recognizes the serial port.
    For example, my laptop is thinkpad x61t,  Itself does not have any serial port, But there is a serial port on the Docking station.
    I am a volunteer, don't work for Lenovo. I am a software engineer.
    thinkpad x61t, os:win7 Awavo Software com port monitor serial port monitor

  • Send thru serial port (RS232) the instruction CTRL+"something"

    How to i send thru a serial port (RS232) the instruction "CTRL", like CTRL+"something", im only looking for the special character CTRL, i have seen that it can send a CTRL+A ... CTRL+Z thru a type cast, but  is not what im looking for, im sending a special instruction (CTRL+PQT<package>) thats requires this character.
    reards

    The control key is not something you can send through a serial connection.  It is a modifier key (like Shift and Alt) and not a character that would have an ASCII value associated with it.
    However, many of the special ASCII control characters (those below decimal 32) can often be entered as a CTRL+key combination.  For instance, the beep is ASCII 8 and is also a CTRL-G combination.  The backspace is ASCII 9 and CTRL-H.  CTRL A is ASCII 1 so sending a string set in hex display as 01 or \01 in \codes display would work.
    What is (CTRL+PQT<package> supposed to mean?  Is it Ctrl P followed by Q T then something else?  What equipment are you trying to interface with?

  • "Example on reading combined signals from a serial port and separating them for display purposes". I am a beginner in Labview and would appreciate if anyone help with that

    I am working on a wireless vital sign monitor. I have 3 signals; heart rate and temperature. I filter and amplify the signals before converting them into digital form. I then pass them via MAX232 before passing them to RS232 serial cable.
    I am therefore working on a program to receive the combined signal and separate them.
    I have come across serial read and write examples on ni.com but am looking for one where I can actually separate combined signals and display them separately.

    Reading the serial port will give you a string. How you divide the channels depends on how the data was formatted before it was sent over the serial channel.
    If you are designing the instrument, as it seems from your query, then you can set up any form you wish. If your data is always floating point numeric, you could use space or tab characters to separate data words. You could use and XML format. If the instrument is provided by a vendor, contact them for the protocol.
    If tabs are used between words and returns between sets of readings, the resutlant string can be interpretted by the Spreadsheet String to Array function in LV.
    Things to avoid are characters often used by serial communications systems as control characters. Carraige returns are
    often used as command terminators by serial protocols, but may also be used by the port.
    Lynn

  • Help with reading information coming from a software into LabVIEW through Serial port

    Hi,
    I am new to LabVIEW and also an amateur in using RS232 for communication. I have this software that has these icons like speed increase/decrease, elevation up/down, start/stop. Now, when I click these buttons on the software, they perform the appropriate functions. For example, if I press start button, the signal must go through a serial COM port into LabVIEW to start the machine. How do I do that? How do I find what format the code word is when I press a button on the software? And how to decode the information to read whether the button pushed is start etc...? Any help would be appreciated.

    I may not be perfect, but I'm all I got!

    That information would be in the programming manual for the device you're controlling. Unless you have a device that has no documentation or you cannot get the documentation that's the first place you should look. If you cannot get the documentation at all then you've got some reverse-engineering to do. To do this you will either need a serial port sniffer (a hardware device), or you can try to use a software-based port capturing program. On Windows PortMon is the most prevalent. This will show you how the port was configured (baud rate, stop bits, etc). Warning: the information is technical.
    As far as how to get it running in LabVIEW, you should take a look at the serial port communication examples that ship with LabVIEW. The most problems occur in figuring out how to (a) terminate a write command, and (b) determining when to stop reading. For (a) this is typically done by appending a carriage return or linefeed to the command. This is device dependent. For (b) this is usually done by the byte stream ending with a character like a linefeed. Again, this is device-dependent. 
    You may also want to peruse this KB article: Serial Instrument Control Tutorial. There are also lots of tutorial on the internet for basic tutorials on serial port communication.

  • How to extract data from a .txt file & send it to a serial port automatically

    Hi all
    I'm a final yr B.Tech student. I am new to the entire LABVIEW thing. But i hear its really good. My dept. in collge has purchased labview & i'm tryng to use it
    As i'm new to labview , i need help plz
    " I want to open a .txt file (in my PC) & transmit all the contents of the file via serial (COM) port to an 89%! microcontroller. Also i want to read the feedback messages from the microcontroller thru the serial port & save it to the same file in the PC.All this must be done automatically. ie, no manual intervention after execution starts"
    Kindly help me as i'm stuck here & unable to proceed further with my project

    here is my 20min try without debugging (needs a rs232 and loopback connector )
    use the probe and highlight the dataflow to see how it works.
    as always:  there are many ways to solve your problem
    Greetings from Germany
    Henrik
    LV since v3.1
    “ground” is a convenient fantasy
    '˙˙˙˙uıɐƃɐ lɐıp puɐ °06 ǝuoɥd ɹnoʎ uɹnʇ ǝsɐǝld 'ʎɹɐuıƃɐɯı sı pǝlɐıp ǝʌɐɥ noʎ ɹǝqɯnu ǝɥʇ'
    Attachments:
    read write file to RS232.vi ‏69 KB

  • Urgent!!! Need help in file read/write data to a serial port

    Hi,
    I really need someone's help in order for me to complete my project. I have attached a vi which I have taken from an example and integrate to my project. In the vi, I have managed to get the encoder counts using Ni 9411. I need to read/write that data from ni9411 to ni9870 without using any serial port as they are connected to a NI 9104 chasis. May I know whether I am correct in writing the data to my ni9870 port using the vi I have attached? Does anyone know how i can convert the number of counts to a 8-bit data/byte so that I can send the data through the RS232 port? I really need someone's help as I need to finished in 2 weeks time.
    I have also attached an vi on controlling the epos2 controller using instrument driver. Does anyone know how can i integrate this vi to the fpga vi (the one which I need to read/write data to 9870) as I need to send those data to control my epos2 controller.
    Please help me!!!
    Attachments:
    Encoder Position & Velocity (FPGA).vi ‏23 KB
    SINGLEMOTORMODIFIED.vi ‏17 KB

    Afai,
    As I allready suggested you here, call your local NI Office and ask for assistance!
    You really need assistence in a higher level that we can provide via the forums. Otherwise I don't see a chance for you to finish your project in time.
    1. Convert I32 to U8 to write it to the 9870 could be done like this:
    2. The vi to control the epos2.
    There is NO way ( absolutely NO way) to port this vi to FPGA. It's based on VISA calls, uses an event-structure, both are not available at the FPGA.
    The only thing you could do is to analyze the VI, the instruction set and design an FPGA vi which handles the specific instructions you would need.
    I have no experience with epos2 and I'm not 100% sure if this would work as you would like to use it. And doing this needs deep knowledge of LabVIEW, VISA, Instrument Drivers, the epos hardware, FPGA programming, and so on... 
    Christian

Maybe you are looking for

  • Custom graphics in java.awt.ScrollPane

    Hi all, I have to draw a custom created image in a scroll pane. As the image is very large I want to display it in a scroll pane. As parts of the image may change within seconds, and drawing the whole image is very time consuming (several seconds) I

  • "Could not use the clone stamp tool because of a program error". How to fix this fault?

    When I try to use the Clone Stamp Tool I am met with the message shown above. I have tried in all the ways I could find to beat this: different photos, switched the computer off and on again, run a de-bugging program through it (Advanced System Care

  • IPod to Library

    I KNOW someone has probably already posted this, but I'm too lazy to go digging around for it, so if you helped that person, you can just pass on the same advice to me. SO I need to know IF you can TRANSFER MUSIC FROM YOUR IPOD TO YOUR ITUNES LIBRARY

  • Report Builder RDF, XML, REP and Version Control

    I'm looking to convert our existing RDF reports to XML format to better support version control and have a few questions. - Are there any issues with converting these RDF files to XML and developing them going forward? - When it's time to deploy to t

  • Best way to clean out a hard drive.

    I have a A505 S605 Satelite laptop with a hard drive full of junk. I would  like to start over by cleaning out the hard drive completely. After the hard drive is cleaned out, I will install everything using the recovery disks that I got from the Geek