RSRV error - ODS objects !

Hello All,
I'm executing the RSRV test --> Foreign Key Relationship of Reporting-Relevant ODS Object and SID Table Characteristics
and I get the error -
SID values missing for 2 specifications of characteristic 0CALDAY
As i understand some values of 0CALDAY are present in the ODS, but have no corresponding SID's in the SID table.
How is this possible? That there are entries in the ODS but no corresponding SID's in SID table of 0calday.
Please advise !
Thanks in advance.

Hi Abhijit,
One case can be that 'Activate even if no master data exists' option is selected and you have not selected the option for 'SID's generation upon activation'. This makes the ODS not suitable for reporting. Hope this helps.
-Raj

Similar Messages

  • Error while activating ODS Object

    Hi,
    I have loaded the data from R/3 to a ODS Object and the activation of ODS failed due to the following errors as shown below..
    -Value '20060 ' of characteristic 0CALQUARTER is     not  plausible
    -Error when assigning SID (details in long text)
    -Activation of data records from ODS object ZODS_02 terminated
    -Error getting SID for ODS object ZODS_02
    I could see that Calendar Quarter as 20060 in PSA. How should i get rid of this error. Any idea would be appreciated.
    Regards,
    Raj

    Raj,
       you are getting this calender qurter from SAP right... check in RSA3 fro the your Datasource. if you are getting same value like '20060'. you can do one thing... you can set 'No Update' in Transfer Rules. you can write a routine in Update Rules for populating the data for calender Week.
    you can call some standard function modules or you can write a small routine. If you want to write a routine check this thread...Re: Date to Quarter
    Possibilites:
    1. updtae rules
    2. if RSA3(PSA) shows the value of the Quarter as '20050', if it is custom extractor(Generic using FM) you can change this.
    3. If it is Standard Extractor or Generic Extractor (using either view/table or Infoset) you can enhance this. you can do the same thing in SAP Side.
    All the best.
    Regards,
    Nagesh Ganisetti.

  • Error while activating ODS Object (urgent)

    Hi Gurus,
    I am getting an error while activating ods object.
    Error/warning in dict. activator, detailed log  --> Detail.
    Row type /BIC/AGLCATODS00 is not active or does not exist.
    Table type /BIC/WAGLCATODS00 could not be activated.
    Table /BIC/AGLCATODS50 could not be activated.
    Table is not yet classified.
    Return code..............: 8.     
    DDIC Object TABL /BIC/AGLCATODS00 has not been activated.
    Error when activating ODS Object GLCATODS.
    If any one have come across this issue please help me out in resolving this issue.
    I will reward points.
    Urs,
    Raki.

    Hi venkat,
    There are only 3 info objects which  i have created it and activated, only those i am pulling in the new ods but its throwing the same error what ever i do changes.
    Is this issue is related to any authorization concerned?
    Urs,
    Raki.

  • Error while activating ODS Object (BIC/WAGLCATODS00 &/BIC/AGLCATODS00 )

    Hi Gurus,
    I am getting an error while activating ods object.
    Error/warning in dict. activator, detailed log --> Detail.
    Row type /BIC/AGLCATODS00 is not active or does not exist.
    Table type /BIC/WAGLCATODS00 could not be activated.
    Table /BIC/AGLCATODS50 could not be activated.
    Table is not yet classified.
    Return code..............: 8.
    DDIC Object TABL /BIC/AGLCATODS00 has not been activated.
    Error when activating ODS Object GLCATODS.
    If any one have come across this issue please help me out in resolving this issue.
    I will reward points.
    Urs,
    Raki.

    Frank,
    There is lot of free space in data base table i already checked it before.... in sm21 it showing database errors.
    Strange i m unable to find out the solution.
    Urs,
    Raki.

  • Error activating ODS object.

    Hi Experts,
    None of the ODS objects gets activated and following are the error messages that i get when i try to activate a ODS object :
    Object ZRSMODS could not be activated
    <b>
    "</b>
    Message no. R7I028
    Transfer structure prefix for source system T90CLNT090 is not defined
    Message no. RSAR325
    Diagnosis
    A prefix is defined for the source system for determining cross-system unique transfer structure names. This prefix is not defined between your source system T90CLNT090 and Warehouse T90CLNT090. There was probably an error when creating the source system.
    Procedure
    If you have not yet loaded data from this source system, delete the source system and then recreate it.
    If the problem occurs again, check the SAP Support Portal. Create a new problem message, if necessary.
    Error when creating the export DataSource and dependent Objects
    Message no. RSDODSO169
    <b>"</b>                                                                               
    Pls send a solution asap. Thank you for the same.

    Hi Aravind,
    Have a look on the following points and see if they are satisfied in your case:
    Check all characteristics involved as described below:
    1. Check the Compounding and Attributes tabs in the characteristics maintenance.
    2. All characteristics here must be active. This is displayed by a green icon.
    If this is not the case for a characteristic involved (a gray icon is displayed on one of the two tabs), activate the characteristic involved. This also activates the inactive dependent characteristics.
    3. After you have checked and repaired all the characteristics involved as described above, the loading/maintenance of master data should work again.
    Because of this you may sometimes get the same error while activating the ODS object.
    Hope it helps...
    Best Regards,
    DMK
    *Assign points if it helps...

  • Error on activation of data records from ODS object

    hi,
    Kindly help with my BW Problem, the error occured on the
    activation of ODS. The error says "<i>Request
    REQU_43MNOPW29W4F5M037J7OAFP52 in ODS ZPUR_O01 must have QM
    status green before it is activated</i>" and "<i>Activation of data
    records from ODS object ZPUR_O01 terminated</i>"
    I tried to check the data in the ODS Object by choosing
    <LS>Administrator Workbench > data targets > context menu on ODS
    Object ZPUR_O01 but the status are green and when i tried to
    activate it the logs says "<i>ODS object ZPUR_O01 was built
    incorrectly. Cannot update request
    REQU_43MODQ3GF69X17B71ZKQMN85I(20,154)
    ODS object ZPUR_O01 was built incorrectly. Cannot update request
    REQU_43MQ8A8F0L1US5COQTUUWX3BA(20,155)
    ODS object ZPUR_O01 was built incorrectly. Cannot update request
    REQU_43MQ8OQQTY21YQ37RMA1WMO06(20,156)
    Data to be activated successfully checked against archiving
    objects                                   
    Activation of data records from ODS object ZPUR_O01 terminated</i>"
    Please help me with this problem.

    Hi Jay
    U need to update these requests to ODS
    REQU_43MODQ3GF69X17B71ZKQMN85I(20,154)
    REQU_43MQ8A8F0L1US5COQTUUWX3BA(20,155)
    REQU_43MQ8OQQTY21YQ37RMA1WMO06(20,156)
    1) delete the current request
    2)Reconstruct the requests above three request
    3)and then Load the current reqest (REQU_43MNOPW29W4F5M037J7OAFP52)
    Then only u will be able to activate the ODS....
    This is an serialization issue...
    hope it helps
    regrds
    AK
    assign points if usefull

  • Error while activation of ODS Object.

    Hi,
    I have loaded the data from R/3 to a ODS Object and the activation of ODS failed due to the following errors as shown below..
    -Value '20060 ' of characteristic 0CALQUARTER is not plausible
    -Error when assigning SID (details in long text)
    -Activation of data records from ODS object ZODS_02 terminated
    -Error getting SID for ODS object ZODS_02
    I could see that Calendar Quarter as 20060 in table /BIC/AZINV_O0240. There is a calendarday mapped to quarter and year in update rules of ODS object. How the calendar quarter is populated in update table in BW. How should i get rid of this error. Any idea would be appreciated.
    Regards,
    Raj

    don't post same issue twice. Bhanu working on your thread.
    check this ...
    Raj,
    you are getting this calender qurter from SAP right... check in RSA3 fro the your Datasource. if you are getting same value like '20060'. you can do one thing... you can set 'No Update' in Transfer Rules. you can write a routine in Update Rules for populating the data for calender Week.
    you can call some standard function modules or you can write a small routine. If you want to write a routine check this thread...Re: Date to Quarter
    Possibilites:
    1. updtae rules
    2. if RSA3(PSA) shows the value of the Quarter as '20050', if it is custom extractor(Generic using FM) you can change this.
    3. If it is Standard Extractor or Generic Extractor (using either view/table or Infoset) you can enhance this. you can do the same thing in SAP Side.
    All the best.
    Regards,
    Nagesh Ganisetti.

  • Error while loading data to ods object from flatfile

    hello all
    Iam loading data from flatfile to ods object and the processing type is PSA and then to data target(package by package),data arrived in PSA(its green) but in monitor the request is in red and in details tab of <b>subsequent processing</b> <b>its showing as ODS activation</b><b>?(change-log):not yet activated</b> and overall the error is <b>Missing Messages</b>.
    and its also saying like "Activation of data records from ODS object ODS_SALES terminated.
    and in help node its saying like data arrived in BW and try to change the request from red to green?
    can anyone tell me what will be the problem?
    In settings of ODS object everthing is set to automatically.
    many thanks
    balaji

    Hi praveen
    problem is <b>generic</b> here.
    In monitor tab the <b>request</b> and <b>overall</b> the statuts is "<b>RED</b>",but when I went into the <b>mange</b> tab of ODS object here the request is "<b>GREEN</b>",but the data is not available here.but data is still available in "<b>New data</b>",how come data is not yet activated.
    bcoz in settings all are set to "automatically",so there is no question of manual activation?
    One more question is in Settings Iam finding one column like "<b>Unique Data Records</b>",whats's this,if v check this what happens ifnot what happens?
    regrads
    balaji

  • Error when transporting ODS Object

    Hi All,
    I got the following error when transporting ODS object.
    "The creation of the export DataSource failed"
    "RFC connection to source system QB1CLNT100 is damaged ==> no Metadata upload"
    "Error when creating the export DataSource and dependent Objects. Error when activating ODS Object 0FIGL_O10"
    Maybe somebody can help me.
    Thanks a lot and appreciate that,
    -Martin-

    hi Martin,
    check oss note 597326 - Activating ODS: Error when creating the export DataSource
    Symptom
    When you activate or transport ODS objects, the following errors appear in the log:
    "The creation of the export DataSource failed". Message number RSBM 035
    "Error &1 in function module &2". Message number RSBM 006
    "<b>Error when creating the export DataSource and dependent Objects</b>". Message number RSDODSO 169
    "Error when activating the ODS object &1". Message number RSDODSO 168
    Other terms
    RSBM 035, RSBM 006, RSDODSO 169, RSDODSO 168
    Reason and Prerequisites
    A characteristic involved is active but it is using new or inactive attributes.
    Characteristics involved are all characteristics used in the ODS object.
    Solution
    Check all characteristics involved as described in the following:
    Check the Compounding and Attributes tabs in the characteristics maintenance.
    All characteristics here must be active. This is displayed by a green icon.
    If this is not the case for a characteristic involved (a gray icon is displayed on one of the two tabs), activate the characteristic involved. This also activates the inactive dependent characteristics.
    After you have checked and repaired all the characteristics involved as described above, the loading/maintenance of master data should work again.

  • Error:Activation of data records from ODS object terminated

    Hi All
    i got error while loading the data "Activation of data records from ODS object terminated '
    could you please tell me procedure how can i solve this issue?
    regards
    vasu.

    - First check the Error Messages from the context menu of the activation step. Also check ST22 & SM21. This will tell you where the error is. Sometimes you might get duplicate records.
    - Next use the "Manage" context menu for the ODS in RSA1. Check if any of the previous records are red. If its red, it would mean that either load/activation has failed for previous request which needs to be corrected first b4 you correct the current one.
    - If al the above are OK, simply repeat the Activation step.
    Hope this helps.
    Regards
    Anujit Ghosh

  • ODS activation error"Activation of data records from ODS object terminated"

    Hi All,
    While activating ODS request I am getting following error
    "Activation of data records from ODS object KFI02O50 terminated ".
    data load is suceesful for ODS but during activation of the request it is giving error.
    I tried to change the status to green manually & then activated the request but still same problem.
    Also I tried to delete request & loaded again from PSA & then activated the request but still same problem
    If anybody has some solution please let me know.
    Thanks in advance
    Regards
    Sonal

    Hi Sonal,
              Sometimes when there is erroeneous records that time while activating the Request request get fails.To check this go to manage tab of the ODS there under log u can see the log icon click on that and check y activation got failed..
    Assign points if its helpful
    Regards,
    vid.

  • Error loading data into ODS object

    Hi,
    I am trying to load some data into an ODS object, which actually does not seem very difficult. I got the InfoObjects  and structure of the ODS object all set up. Transfer rules are defined and I succeed in loading the data into PSA.
    From there i trigger the forwarding into the ODS object. And this is what i get (I use the BI in German, so maybe the translations are not 100% correct):
    message missing: tranfer rules finished.
    seems like the system does not get a esponse as to whether the transfer rules are worked through yet. this results in a timeout because nothing happens.
    i'm sorry i cant give any more detailed information. maybe someone can give me a direcion in which to search for mistakes.  irebuilt the transfer rules and compared with others, and found nothing. still the same problem...
    cheers,
    stefan

    Oh yeah, that error message i've been talking about was actually a note in the details of the monitor.
    you can see it here:
    http://www.fape.info/files/data_transfer_monitor_details.bmp
    let me give you some translation.
    - status: some error occured.
    -- data request, ok
    -- extraction, some error
    -- transfer
    ****data packet 1: received in bw, data not processed yet
    ****data packet 2: ...
    ****data packet 3: ...
    -- processing
    --- data packet 1:
    ++++ transfer into PSA, no problem
    transfer rules: error
    ******processing started
    ******missing response: transfer rules complete
    i hope this gives an idea.
    i couldn't come up with any solution so far. don't know why this response is missing after the processing of the data started.

  • SAP BW ERROR OCCURS WHILE CREATING ODS OBJECT

    HI TO SAP BW GURUS
    AFTER CREATING ODS OBJECT,AND ODS OBJECT STRUCTURE,WHILE ACTIVATING THE STRUCTURE I AM GETTING MESSAGE AS
    <b>message : STDO:LOG COULDNOT BE WRITTEN ON OUTPUT DEVICE T</b>
    COULD ANYONE PLS TELL ME HOW TO RECTIFY THT
    VENKAT

    Read the information message carefully. Then proceed, if you intend to have custom  "standard" texts (sort of an oxymoron, but everyplace I've been does this)...
    If you are working in a customer system, only create standard texts using the following naming convention:
    Initial letter Y or Z in the text name with any text ID
    or
    Initial letter Y or Z in the text ID with any text name

  • Ods object must be regenerated

    hi bcsgurus
    lemme know when does this error occur n how do i eradicate it
    i am copying the databasis and generating  it.
    ods object must be regenerated
    data may get lost when this is is regeneated.
    i tried activating the ods again too.
    thanks

    hi bcsgurus
    Sorry for the SMS language.
    thanks for the welcome
    I am creating a databasis whihc is using a z123cube
    and when i generate the data basis
    "ods object must be regenerated
    data may get lost when this is is regeneated." is the error .
    i tried activating the ods again too.
    is it because of using the same cube which has already been used?
    let me know if i have to create another cube.
    thanks

  • ODS object failing to activate

    Hello All,
    I will greatly appreciate your help with the following issue:
    I have an ODS object that is failing to activate complaining that "Value 'HAGas Cartridge Actu.in safety enclosure  ' (hex. '00480041004700610073002000430061007200740072006900') of characteristic 0PROD_DESCR contains invalid characters"
    If I am correct - invalid characters were uploaded to an InfoObject (0PROD_DESCR) and now the ODS object does not want to activate (0PROD_DESCR is an InfoObject inside the ODS object). To fix this - does a reload of this characterstic 0PROD_DESCR need to be done without the invalid characters?
    Regards,
    Keith Kibuuka

    Hi Keith,
    If you notice the data that is coming for the field 0PROD_DESCR.
    One thing is it has data with lower case letters,
    secondly from the error message you can notice that '." is also present.
    If you analyse all the data in the request either in the PSA or in the active data table of the ODS you will find out what other special characters are used.
    If you want to load the data as it is you can add the special chars in RSKC, the text ALL_CAPITAL is not sufficient.
    If you do not want to add the special chars then you should edit the data in the PSA and reload the data in to the ODS and then activate the same
    Assign points if useful
    Regards
    Venkata Devaraj
    Message was edited by:
            Venkata Devaraj

Maybe you are looking for

  • Copy text in pdf gives me gibberish. Is there a way to OCR to correct?

    I have a few documents that are complete gibberish when I select text and copy. If I open them in Acrobat Pro, select text, Copy, and "Show Clipboard" in Finder, I see a bunch of "skull characters", and if I open them in Preview and do the same, I se

  • Calling functions in a package from jdbc

    I am trying to call a function in a PL/SQL package from a java program using JDBC. Is this a valid option? The statement I am using is the following: stProc = myconnect.prepareCall ("{? = call process_monitor_pkg.open_sod_cursor}"); I am receiving th

  • Solaris 10 Installed with VMware Server 1.0.3 free version

    Hello I am a beginner in S 10 and planned to start learning it installing S 10 on a VMware server 1.0.3 (free) on my machine where I have win xp pro pre-installed. I downloaded S 10 SW as ISO for CD and installed the same. My problem is the entire fi

  • About Forms JAVA UI Component AppletSecurityException

    Hi, I have been researching how to access a custom OCX control from Web Forms 6i application, and I came up with a third-party JAVA to COM bridging solution, J-Integra from Intrinsyc. With J-Integra I was able to build a PJC compatible JAVA component

  • Multple Reports From One Master

    I am a new user of Hyperion Reports. I would like to export a report in HTML to an external directory using the descendants of a dimension. There are approximately 2,000 descendants. Then I would like to link the exported HTML reports to individual w