RT Communication Wizard error 1055

When i use the Real Time Communication Wizard i get this message: Error 1055 occurred at Property Node in RTCW Script NPL (TCP).vi->RTCW Wizard.vi
Whats wrong??? I get this Error in every VI but i´ve already re-installed RT

This is a known and solved issue that is documented in the NI knowledgebase. Please follow this link.
Best regards
Jochen Klier
National Instruments Germany

Similar Messages

  • Visio Database Wizard Error

    I try to connect visio 2013 to a sql database. Purpose is to have shape data in sql database (not in excel or access).
    I use the database wizard from the Add-Ons section in Visio and whatever existing table I select or whatever table I create from within this wizard (Define Table option) I get the following Visio Database Wizard Error:
    'The selected table has one field or contains no definition information. The Database Wizard requires a minimum of one key field and one additional data field.'
    Note that I tested succesfully to export the complete existing drawing to a database table using one of the other options and that I get exactly the same error when pointing to this exact table in sql server when starting the database wizard.
    To be complete: I use Visio 2013 pro and SQL 2008 R2 Express edition.
    Any thoughts?

    Hi,
    To the error message, the reason this error occurs is that the length of the Filepath to the sql database is too long. Visio has a hard limitation of 128 characters for a complete path.
    There are a couple of ways to avoid this issue.  
    1. On a local drive, move the files to a location ‘higher’ in the folder list, to shorten the full pathname. 
    2. For a remote share, change the level of the drive letter mapping to a higher level to shorten the full pathname.
    Similar to issue described in article:
    http://support.microsoft.com/kb/287624/en-us
    Regards,
    George Zhao
    TechNet Community Support
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • I'm getting error 1055

    I'm getting an error 1055 in the report generation - my Labview ver is 8.6.1
    I don't know what to do here to resolve this  
    I thank for your help.
    Dana
    Solved!
    Go to Solution.
    Attachments:
    err vi.png ‏71 KB

    thank you very much that works !!

  • Error 1055 occurred at Property node

    Generating the error:
    "Error 1055 occurred at Property Node in ...   Possible reason(s):  LabVIEW object reference is invalid."
    when I try to wire the IMAGE OUT output from the IMAQdx Snap vi to the value property of an externally referenced image display control.
    To describe in more detail, I have a parent vi with an image display control and a child vi which has a control refnum linked to the parent vi display. In the child vi I create a value property for the refnum and try to write images to it, essentially to drive the parent display from the child vi.
    The technique works elsewhere, though I can't think of what I could have done differently to generate this error?

    Hi Mike - looks like I may not need to. I've been working away at this and have found the original cause and something else a bit weird...
    I deleted the objects from the sub-VI that was giving me errors, then cut and pasted the objects (image display refnum and value property) from a VI that was working and this solved the problem. So you might think that the issue was just some obscure configuration item, or I'd used the wrong type in my reference or something.
    I found the display reference in the parent VI was not even wired to the sub VI - duh! Error between keyboard and chair. So at least the original error message made sense, but I have no idea why it actually worked after pasting in the new objects. Are these references using some sort of auto-magic? Who knows. Safer to wire up my sub-VI's properly methinks.
    Sorry for wasting forum time on this one.

  • Build error after upgrading from 8.2.1 to 8.5 "Error 1055 occurred at Invoke Node..."

    After upgrading to 8.5, I'm getting the following error when trying to build an EXE:
    Visit the Request Support page at ni.com/ask to learn more about resolving this problem. Use the following information as a reference:
    Error 1055 occurred at Invoke Node in AB_Source_Library.lvclass:Close_Reference.vi->AB_Build.lvclass:Copy_Files.vi->AB_Application.lvclass:Copy_Files.vi->AB_Build.lvclass:Build.vi->AB_EXE.lvclass:Build.vi->AB_Engine_Build.vi->AB_Build_Invoke.vi->AB_Build_Invoke.vi.ProxyCaller
    Possible reason(s):
    LabVIEW:  Object reference is invalid.
    I have been building this application for both Windows and Mac OS, and I even get the same error when building the .app on an Intel Mac.
    Things that I've already tried:
    * Mass-compiling all my code
    * Created the project from scratch
    * Enabled each panel of the "diagram disable structure" one at a time and compiled again
    Any ideas?

    Hi Travis,
    Ben’s advice if definitely the best place to start. Error 1055 is a very general LabVIEW error for “Object reference is invalid.” The cause is usually a bad install where important LabVIEW function aren’t placed in the right directory or aren’t installed at all.
    Charlie M. CLD

  • Import expoort wizard error on sql server 2008r2

    - Executing (Warning)
    Messages
    Warning: Preparation SQL Task 1: Multiple-step OLE DB operation generated errors. Check each OLE DB status value, if available. No work was done. (SQL Server Import and Export Wizard)
    Warning: Preparation SQL Task 1: Multiple-step OLE DB operation generated errors. Check each OLE DB status value, if available. No work was done. (SQL Server Import and Export Wizard)
    - Copying to `tblSFUpload` (Error)
    Messages
    Error 0xc0202009: Data Flow Task 1: SSIS Error Code DTS_E_OLEDBERROR.  An OLE DB error has occurred. Error code: 0x80004005.
     (SQL Server Import and Export Wizard)
    Error 0xc0209029: Data Flow Task 1: SSIS Error Code DTS_E_INDUCEDTRANSFORMFAILUREONERROR.  The "input "Destination Input" (615)" failed because error code 0xC020907B occurred, and the error row disposition on "input "Destination
    Input" (615)" specifies failure on error. An error occurred on the specified object of the specified component.  There may be error messages posted before this with more information about the failure.
     (SQL Server Import and Export Wizard)
    Error 0xc0047022: Data Flow Task 1: SSIS Error Code DTS_E_PROCESSINPUTFAILED.  The ProcessInput method on component "Destination - tblSFUpload" (604) failed with error code 0xC0209029 while processing input "Destination Input" (615).
    The identified component returned an error from the ProcessInput method. The error is specific to the component, but the error is fatal and will cause the Data Flow task to stop running.  There may be error messages posted before this with more information
    about the failure.
     (SQL Server Import and Export Wizard)
    Error 0xc02020c4: Data Flow Task 1: The attempt to add a row to the Data Flow task buffer failed with error code 0xC0047020.
     (SQL Server Import and Export Wizard)
    Error 0xc0047038: Data Flow Task 1: SSIS Error Code DTS_E_PRIMEOUTPUTFAILED.  The PrimeOutput method on component "Source - tblSFUpload" (1) returned error code 0xC02020C4.  The component returned a failure code when the pipeline engine
    called PrimeOutput(). The meaning of the failure code is defined by the component, but the error is fatal and the pipeline stopped executing.  There may be error messages posted before this with more information about the failure.
     (SQL Server Import and Export Wizard)
    - Post-execute (Success)
    Messages
    Information 0x4004300b: Data Flow Task 1: "component "Destination - tblSFUpload" (604)" wrote 65535 rows.
     (SQL Server Import and Export Wizard)
    Can someone tell me what to do with this please?

    Hi faiz,
    >>Error 0xc02020c4: Data Flow Task 1: The attempt to add a row to the Data Flow task buffer failed with error code 0xC0047020.
    According to this message, it can be caused by that there is not enough memory available or the buffer size is too small. To resolve this issue, I recommend you perform the following steps.
    1. Change the Server memory configuration of the SQL server. For example, you can increase maximum memory via the following scripts. For more information, please review this article:
    Server Memory Server Configuration Options.
    sp_configure 'show advanced options', 1;
    GO
    RECONFIGURE;
    GO
    sp_configure 'max server memory', 4096;
    GO
    RECONFIGURE;
    GO
    2. Adjust the buffer size by increasing the DefaultBufferMaxSize and DefaultBufferMaxRows properties of Data Flow tasks. For more information about it, please review this article:
    Data Flow Performance Features.
    Thanks,
    Lydia Zhang

  • XI Communication Channel Error Explanation

    Hi All,
    Does anyone happen to know :-
    1)  Is it possible to use CCMS to email the errors coming from a communication channel error Explanation field
    2)  Are these messages stored in a table I can check
    The reason I need to know this is because we sometimes encounter an error such as "Conversion of file content to XML failed at position 838: java.lang.Exception: ERROR converting document line no. 839 according to structure 'XXX_XXX_XXX':java.lang.Exception: ERROR in configuration / structure 'XXX_XXX_XXX.': More elements in file csv structure than field names specified!
    This tells us exactly where the error occurred but using Communication Channel Monitoring the error message only remains for a little while before the polling messages remove it from the display.  Since the process runs early hours of the morning we never get to see these messages.
    Any help appreciated.
    Thanks
    Craig

    Hi Raquel,
    Let me try to clear out some things in this thread . First of all you do your alert configuration which you say you have already done. Thats good . Now you ask that you want only to monitor the communication channels and you want specific guide . Here is the specific guide.
    If you have configured alerts you will know that when you create an alert rule you have the option to choose radio button where did the error occur it could be no restriction , integration engine or adapter engine. You need to choose adapter engine.
    Now whenever the colour of the lights change to red. You will get your alerts.
    Regards
    joel
    Edited by: joel trinidade on Apr 9, 2009 9:41 AM

  • View not copied or enhanced with wizard Error while creating Event Handler method in Z Component

    Hello Friends,
    In one Z Component (Custom Component), in one of the views, while creating event handler, it gave me error message that view not copied or enhanced with wizard.
    I am aware that in Standard Component, if we want to create the event handler method then we need to first Enhance the Component and then we need to enhance the view.
    But, in the Z Component (Custom Component), how to create event handler method in one of the views as while creating event handler method i am getting view not copied or enhanced with wizard error.

    Hi,
    Add a method in views impl class with naming convention eh_on__* with htmt and html_ex parameters.  I dont have have the system right now. Please check any existing event import export parameters.
    Check out do handle event method in the same class.
    Redefine that method.  Call that event method in this handle method. See existing code for reference.
    Attach that event to the button on click event in .htm page.
    Regards,
    Bhushan

  • When deploy: Wizard error a connection to the deployment share could not be made "check physical connection"

    Hello everybody,
    yet another issue with deploying a masterdisk. I will give you a short explanation of the situation.
    I need to deploy Windows 8.1 PRO x86. 
    Using: Microsoft Deployment Workbench Microsoft Version: 6.2.5019.0
    1. Reference PC: Windows 8.1 PRO x86 is installed on ORACLE Virtual Box.
    2.  I installed  MDT on my workstation Windows 7 x64, where "C:\DeploymentShare\Windows8" is located.
    3. To change the Unattended.xml file, I have second ORACLE Virtual Box with
    Windows 8.1 PRO x86 with MDT, which connected to the DeploymentShare of Windows 7 x64.
     - The reason is because the Reference PC is x86 and the Unattended.xml file can be changed only if MDT is installed on x86 Windows, otherwise it is not possible.
    The image capture is successful.
    Then I create bootable USB device using rufus-1.4.12.exe. I use: C:\DeploymentShare\Windows8\Boot\LiteTouchPE_x86.iso
    I use a real PC (not virtual machine) and when the deployment starts
    I see: 
    1 Welcome screen, where I select: Run the deployment wizard to  install a new operating system.
    2. The next screen is an error screen where I see the error: 
    "Wizard error
    A connection to the deployment share (\\ComputerName\C\DeployemntShare )could not be made
    DHCP Lease was not obtained for any Networking devices!
    Possible cause: Check physical connection
    I am relatively new with MDT.
    Any suggestions are more than welcome.

    Nick,
    Thank you for the answer!
    Yesterday, I figured out that I need to create an offline bootable disk. 
    The issue is caused, because creating a bootable disk with rufus.exe include only the ISO file and not the WIM file. That is the reason why during OS installation process it asks me for the shared folder...

  • Getting end-of-file on communication channel error on this query

    Hi guys,
    I'm getting the end-of-file on communcation channel error when running the following query in SQL PLUS, If run it in a stored procedure called through code of JDBC, it gave "no more data to read from socket" error. Any idea what went wrong? kind of frustrated now. We are using the Oralce 9.0.1.4.0, which suppose to fix some sdo_uion and sdo_buffer bugs. Thanks a lot!!
    select SDO_GEOM.SDO_BUFFER((SELECT SDO_AGGR_UNION(MDSYS.SDOAGGRTYPE(GEOLOC, 0.011119487)) FROM GEOTEL_SOURCE where MSA='5000' and COMPANY_NAME ='AMERICAN FIBER SYSTEMS'),1.0,5,'unit=MILE arc_tolerance=0.05') from GEOTEL_SOURCE a where a.MI_PRINX = 1;

    Hi Daniel,
    Just tried the 9.2.0.2 patch, seems to work better now. At least I don't get the end-of-file on communication channel error. But how about the speed thing? I isolated the problem, and find out that sdo_aggr_union is taking too long to finish( 1 Hour!!! for 2300 lines with the same city. Any clue to optimize it, I tried some hint like /*+ordered*/ No_Merge and something like that, does not improve though. Thanks!                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           

  • OIM 11g Server Configuration Wizard Error - Cannot Connect to Oracle DB

    I appreciate any and all suggestions or thoughts on how to best continue troubleshooting this error that I am describing below.
    I am attempting to install Oracle Identity and Access Management Suite 11g on a Windows 7 machine…in following the installation guides I have successfully installed the following Oracle Components
    - Oracle Database 11.2.0.1.0
    - Created Schemas using RCU 11.1.1.3.3
    - Oracle WebLogic Server 10.3.3.0
    - Oracle SOA 11.1.1.2.0
    - Oracle SOA 11.1.1.3.0 (Patch Set)
    - Oracle IAM SUITE 11.1.1.3.0
    Following the above installations, I created a new WebLogic Domain and as the next step am running the OIM Configuration Wizard to configure the OIM Server, however I am unable to setup a connection to the Oracle DB via the OIM Configuration Wizard. I am getting an error message when attempting to setup the connection to the Oracle Database using the OIM 11g Server Configuration Wizard:
    ERROR:*
    INST:6102 Unable to connect to the database with the given credentials.
    *+[DETAILS] Check the values. Make sure the Database is up and running and connect string, user name, and password are correct.+*
    INST:6102 Unable to connect to the database with the given credentials.
    *+[DETAILS] Check the values. Make sure the Database is up and running and connect string, user name, and password are correct.+*
    When installing the Oracle Database 11gR2 I used the following install configuration:
    Oracle base: C:\MyApps\Oracle
    Software location: C:\MyApps\Oracle\DB_HOME\11.2.0\dbhome_1
    Database file location: C:\MyApps\Oracle\DB_HOME\oradata
    Database Edition: Personal Edition (3.27 GB)
    Character Set: Unicode (AL32UTF8)
    Global database name: orcl.dev.com
    Administrative Password: Password1
    Confirm Password: Password1
    When creating my Schemas using RCU 11.1.1.3.3 I used the following Database Connection Details
    DB TYPE: Oracle Database
    HOST NAME: localhost
    PORT: 1521
    SERVICE NAME: orcl.dev.com
    USERNAME: sys
    PASSWORD: Password1
    ROLE: SYSDBA
    I used a Prefix of “DEV” when creating the schemas so Schema Owners DEV_OIM and DEV_MDS where created. Also, I configured to use the same password for all Schemas: “Password1″. So the password for DEV_OIM and DEV_MDS should be the same, “Password1″.
    REPRODUCING THE ERROR
    To reproduce the error, when I launch the Oracle Identity Management 11g Configuration Wizard I am first brought to the “Welcome” Screen. I click the [Next>] button.
    Next, I am on the “Components to Configure” screen where I select OIM Server and OIM Design Console and click the [Next>] button. (NOTE I have also tested by simply selecting only the OIM Server)
    Next, I am on the “Database” screen where I enter the connection information
    Connection String: localhost:1521:orcl.dev.com
    (NOTE I have also tested using localhost:1521:orcl)
    OIM Schema User Name: DEV_OIM
    OIM Schema Password: Password1
    MDS Schema User Name: DEV_MDS
    MDS Schema Password: Password1
    When I click the [Next>] button after entering the Database Connection details I encounter the following two errors (1 error for each logon DEV_OIM and DEV_MDS)
    INST:6102 Unable to connect to the database with the given credentials.
    INST:6102 Unable to connect to the database with the given credentials.
    TROUBLESHOOTING
    NOTE: I can successfully start the Oracle DB Services and connect via the Enterprise Console, SQL Plus, and JDBCTest Java Client…I just cannot get past this connection error in the OIM Server Configuration Wizard.
    JDBCTest.java TEST CLIENT
    NOTE: THIS IS THE JAVA TEST CLIENT THAT I AM USING TO TEST DATABASE CONNECTIVITY THRU A SPECIFIED JDBC URL AND DRIVER THAT WORKS SUCCESSFULLY.*
    import java.sql.Connection;
    import java.sql.DatabaseMetaData;
    import java.sql.DriverManager;
    import java.sql.ResultSet;
    public class JDBCTest {
    public static void main(String[] args) throws Exception {
    String url = "jdbc:oracle:thin:@localhost:1521:orcl";
    String driver = "oracle.jdbc.OracleDriver";
    String user = "DEV_OIM";
    String password = "Password1";
    try {
    Class.forName(driver);
    Connection conn = DriverManager.getConnection(url, user, password);
    // Get the MetaData
    DatabaseMetaData metaData = conn.getMetaData();
    // Get driver information
    System.out.println("");
    System.out.println("#########################################");
    System.out.println("# ***DRIVER INFORMATION***");
    System.out.println("#");
    System.out.println("# Driver Name = " + metaData.getDriverName());
    System.out.println("# Driver Version = " + metaData.getDriverVersion());
    System.out.println("#");
    System.out.println("#########################################");
    System.out.println("");
    System.out.println("");
    // Get database information
    System.out.println("#########################################");
    System.out.println("# ***DATABASE INFORMATION***");
    System.out.println("#");
    System.out.println("# Database Product Name = " + metaData.getDatabaseProductName());
    System.out.println("# Database Product Version = " + metaData.getDatabaseProductVersion());
    System.out.println("#");
    System.out.println("#########################################");
    System.out.println("");
    System.out.println("");
    // Get schema information
    ResultSet schemas = metaData.getSchemas();
    System.out.println("#########################################");
    System.out.println("# ***SCHEMA INFORMATION***");
    System.out.println("#");
    System.out.println("# Schemas:");
    while (schemas.next()) {
    System.out.println("# " + schemas.getString(1));
    System.out.println("#########################################");
    System.out.println("");
    System.out.println("");
    // Get table information
    System.out.println("Tables");
    ResultSet tables = metaData.getTables("", "", "", null);
    while (tables.next()) {
    System.out.println(tables.getString(3));
    conn.close();
    } catch (Exception ex) {
    ex.printStackTrace();
    *"lsnrctl status" COMMAND TEST SUCCESSFUL*
    When the Listener Service is on I get the following output using lsnrctl status command
    C:\> lsnrctl status
    LSNRCTL for 32-bit Windows: Version 11.2.0.1.0 - Production on 21-SEP-2010 15:59:43
    Copyright (c) 1991, 2010 Oracle. All rights reserved.
    STATUS of the LISTENER
    Alias LISTENER
    Version TNSLSNR for 32-bit Windows:Version 11.2.0.1.0 - Production
    Start Date 21-SEP-2010 14:43:57
    Uptime 0 days 1 hr. 15 min. 46 sec
    Trace Level off
    Security ON: Local OS Authentication
    SNMP OFF
    Listener Parameter File C:\MyApps\Oracle\DB_HOME\11.2.0\dbhome_1\NETWORK\ADMIN\listener.ora
    Listener Log File c:\myapps\oracle\diag\tnslsnr\\listener\alert\log.xml
    Listening Endpoints Summary…
    (DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)(HOST=127.0.0.1)(PORT=1521)))
    Services Summary…
    Service “CLRExtProc” has 1 instance(s).
    Instance “CLRExtProc”, status UNKNOWN, has 1 handler(s) for this service…
    Service “orcl.dev.com” has 1 instance(s).
    Instance “orcl”, status READY, has 1 handler(s) for this service….
    Service “orclXDB.dev.com” has 1 instance(s).
    Instance “orcl” status READY, has 1 handler(s) for this service…
    The command completed successfully

    Whenever installing oracle databases, i install the software only first. Then i setup the listener. Then i create a database instance using the dbca tool. This way all the information is added to the pre-existing listener configurations rather than trying to create the listener afterwards. Also, during the dbca database creation, i supply a full service name such as orcl.hostname and use the service name in future configurations where it asked. This usually solves any issues of the listener or database not being found correctly.
    -Kevin

  • Fatal two-task communication protocol error (when using  db link)

    I have created the db link betwen two databases of oracle version 9i 9.0.2
    the db link connects to specific user
    when i access the table with same name as user then recieve following message
    ORA-03106: fatal two-task communication protocol error
    when i access the other tables having different name that the user to which the db link connects
    that works alright
    so what is solution of problem in this particular case?

    What is your Oracle release? Is it 9.0.1.2 or 9.2.0?
    What version of Sql*Plus client are you using?

  • Transport error: Communication failure error

    I am trying to access Crystal Enterprise that is behind a firewall and am getting an Transport error: Communication failure error.  I have tried the following:
    1)  Opened the 6400 port for the CMS.
    2)  Set -requestport in the command line to a different port, that is also open, for the Output Server and the Input Server.
    Does anyone know what I am doing wrong?  I haven't been able to locate the documention on how to run behind a firewall.  I am newby on the admin side.
    I am running this on Windows 2003 server.
    Thanks in advance.

    I can tell you from Business Objects Enterprise perspective. 6400 is the port on which CMS listens. We have web server in the DMZ so we had to open another set of ports also. We opened 2000-5000 ports also between Web server and application server ( where services are installed). The reason being that CMS listens on 6400 but other services listens on randomly selected ports different from 6400. Look into the registry entry and you will find CER. Inside CER there are two Keys RequestLowerPort and RequestUpperPort. We have defined these as 2000 to lower and 5000 to upper one.
    You can set ports using -requestport and open that ports and see how it works. Opening only 6400 would not  work is my guess.

  • ORA-03113: end-of-file on communication channel ERROR

    After applying Database patch 3095277 to my 9.2.0.1.0 installation
    in order to update it to 9.2.0.4.0,I'm getting ORA-03113: end-of-file on communication channel
    ERRORS when attempting various tasks. This is a local installation running on a Windows XP Workstation.
    I've even tried creating a new test database but the result is the same.
    The reason for moving up to 9.2.0.4.0 is so I can start using Advanced Queuing, which I understand had problems in earlier releases.
    However before the update I could at least create the JMS queue tables without ERROR whereas now I get the following errors when attempting to create a queue table in SQL Plus from within Enterprise Manager Console.
    SQL*Plus: Release 9.2.0.4.0 - Production on Thu Sep 18 08:20:08 2003
    Copyright (c) 1982, 2002, Oracle Corporation. All rights reserved.
    Connected.
    BEGIN SYS.DBMS_AQADM.CREATE_QUEUE_TABLE(Queue_table=> 'JMSQTBL',Queue_payload_type=>'SYS.AQ$_JMS_STREAM_MESSAGE',multiple_consumers=> false); END;
    ERROR at line 1:
    ORA-03113: end-of-file on communication channel
    BEGIN SYS.DBMS_AQADM.CREATE_QUEUE(Queue_name=> 'JMSQUE',queue_table=> 'JMSQTBL'); END;
    ERROR at line 1:
    ORA-03114: not connected to ORACLE
    I would be grateful of any pointers as to how to resolve this problem.
    Regards
    Gary.

    Chris, Thanks for the suggestion,
    I took a look in the trace log and found the following entries that point to a ORA-00600 as you mentioned earlier.
    This is only a test database so there's no great loss if
    I have to re create it, but in saying that I did create a new test02 from scratch and had the same problem.
    Is it posible something went wrong when applying the 9.2.0.4.0 patch ?.
    Regards
    Gary.
    Dump file c:\oracle\admin\test01\udump\test01_ora_2556.trc
    Wed Sep 17 16:25:14 2003
    ORACLE V9.2.0.4.0 - Production vsnsta=0
    vsnsql=12 vsnxtr=3
    Windows 2000 Version 5.1 Service Pack 1, CPU type 586
    Oracle9i Enterprise Edition Release 9.2.0.4.0 - Production
    With the Partitioning, OLAP and Oracle Data Mining options
    JServer Release 9.2.0.4.0 - Production
    Windows 2000 Version 5.1 Service Pack 1, CPU type 586
    Instance name: test01
    Redo thread mounted by this instance: 1
    Oracle process number: 10
    Windows thread id: 2556, image: ORACLE.EXE
    *** 2003-09-17 16:25:14.046
    *** SESSION ID:(7.17) 2003-09-17 16:25:14.031
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** Object defn.s out of sync w/ data
    *** 2003-09-17 16:25:14.281
    ksedmp: internal or fatal error
    ORA-00600: internal error code, arguments: [qmxiUnpPacked2], [121], [], [], [], [], [], []
    Current SQL statement for this session:
    select 1
    from resource_view
    where any_path = '/xdbconfig.xml'
    ----- PL/SQL Call Stack -----
    object line object
    handle number name
    6A4FA348 6 package body XDB.DBMS_REGXDB
    6A504D88 1 anonymous block
    6A576AB8 639 package body SYS.DBMS_REGISTRY
    6A1DBB6C 1 anonymous block

  • Application builder error 1055

    ed. cross-post: http://lavag.org/topic/18047-application-builder-error-1055/
    Hello everyone
    I have a big problem with building applications lately. The build is running fine until the end, when it throws:
    Error 1055 occurred at Property Node in VISL_findDependentVISvr.vi->VISL_findAndProcessVISvrList.vi->VISL_detectAndCopyVISvr.vi->AB_Engine_Copy_CustomIOServer_Files.vi->AB_EXE.lvclass:Copy_Files.vi->AB_Build.lvclass:Build.vi->AB_Application.lvclass:Build.vi->AB_EXE.lvclass:Build.vi->AB_Engine_Build.vi->AB_Build_Invoke.vi->AB_Build_Invoke.vi.ProxyCaller
    Possible reason(s):
    LabVIEW: Object reference is invalid.
    Has anyone seen this error in app builder? Does anyone have any idea how can I resolve this problem?

    Lennard, Valko
    I'm using LV 2013 f2. Let me give you some more details and... The story how I fixed it:
    The project is pretty big (~1500 VIs) and highly object-oriented (~300 classes). It has RT (PXI) and PC part. Some of the classes are shared between PC and RT. The problem with build was present only on PC - build for RT was ok.
    I had DSC module installed, but it was not used in this project at all. Despite that, when I found information from Lennards link, I've tried to build it using "Enable Enhanced DSC Run-Time support". It didn't help. I started to wonder if the sharing of classes between RT and PC has something to do with the problem. So I refactored the project, splitted it into two projects (one for PC, one for PXI) and reduced number of shared classes (especially some specific classes, which implement "threads"). Afterwards, the build could be done just fine, but only in those refactored projects.
    Now for the plot twist: before refactoring, I've tried to build the project on another computer. It was build without any problems! So I started to look for the differences. First of all, just before the build I've updated one of our internal libraries in VIPM and changed its name - so it was my main suspect (I needed to update dependencies in project as the change of VIPM package name changed it folder in vi.lib). This + disconnecting code from VIs and I though that I've just found another way of destroying LV compiler completely. Still, I couldn't fix it in any way...
    As per Valko suggestion I've uninstalled DSC module completely. Once again - my project does not explicitly use this module at all! Removing the module didn't broke anything in the project. And guess what? The build was done without problems! I've even tried to do this build again on the code revision before refactoring, and the build was done!
    tl;dr: REALLY NI!!?!? REALLY!? YOU'VE BROKEN SOMETHING IN THE MODULE WHICH I DON"T EVEN EXPLICITLY USE AND MADE ME LOSE FEW DAYS OF WORK JUST TO FIND IT OUT? REEEEAAAAALYYYYY!?

Maybe you are looking for