Run time error in Bex broadcasting with pdf as output format.

Hi,
In bex broadcasting settings:bursting by e-mail with out put type as pdf format,the out put of query is coing as well up to 3000 records in query output.If number of records in query output is greaterthan 3000,then an runtime error is coming.
If there is an output option as HTML format with "as zip file check box" by default.
But user wants output in "pdf format" only.
Can you suggest if any settings can be made in bex broadcasting settings.
Thnaks in advance.
Yours,
chinna.

Hi,
this might be of timeout error..
plz make timeout settings as per this SAP Note Number: 934275 and try
thnks.

Similar Messages

  • Run Time Errors in BEx Report Designer?....asking for Portal Setup??

    In BEx Report Designer, I keep getting short dumps and timeouts when trying to design flashy reports.
    I keep getting 2 errors when I time out:
    1. 'Query (view) definition cannot be retrieved from Portal.
    Please try again or check query and Portal Setup!
    Time limit exceeded.
    2. xxx Error when reading Query (via BICS)
    Please check query and Portal setup!
    Time limit exceeded.
    We are running ECC 6.0, BI2004s, and SEM 6.0.  All in Sandbox/Dev environment.
    We are NOT running EP. 
    I am aware that we have some memory issues, and we're adding 4Gb more on Thursday....can the solution be that simple, or are these errors telling me we need Portals installed?  I was under the impression that Portals were NOT required for 2004s, so long as you did not use WAD etc.
    Any thoughts??

    You would need to install portals(EP) for the report designer to work. When you design your flashy report in designer and try it launch it... it would try to connect to EP to publish it. It bombs when it doesnt find the portal.
    On a personal note: Report designer have a long way to go when you think the output would be something like crystal .. NO not yet ... But SAP just got started ... I think they would be there pretty soon. And they promise many enhancements as of SP 13.. so lets all wait.

  • Run time error when calling Start() method from an Output counter user control in my class.

    I am new to DAQmx and .NET.
    In my application I need to activate a clock out on counter 2 (HW pci 16 E 4).
    I went through all the steps like the sampling examples but instead of Analog input
    I used counter output , and setup the pulse ratios.
    When I click the switch in the user interface ( a user control databinded to the clock output)
    the output works. Since I need to activate it programmatically I tried to call the daQmxUserControl11.Start()
    method but this causes the following error :
    An unhandled exception of type 'NationalInstruments.DAQmx.DaqException' occurred in nationalinstruments.daqmx.dll
    Additional information: Specified operation cannot be performed while the task is running.
    Task Name: DAQmxTask1
    Status Code: -200479
    Any ideas on what am I doing wrong?
    Thanks David

    Thanks a lot,
    I also discovered that dragging the user control onto my user interface doesn't allow alternate activation.
    ( I actually tried stopping and then starting but the result was the same )
    Calling the routines as indicated in the header comments also gave some hiccups ( I had to remark some code to get the system working progrtammatically.
    public void Start()
    #region Update UI
    this.switch1.Caption = "On";
    this.switch1.Value = true;
    #endregion
    daqmxTask.Start();
    public void Stop()
    #region Update UI
    this.switch1.Caption = "Off";
    this.switch1.Value = false;
    #endregion
    daqmxTask.Stop();
    #region Methods

  • Run time error in Web Application design

    I have several run time errors whe I deal with big web templates in WAD. Sometimes the error raises when i try to move in html section of the web template (run time error 5: invalid procedure call or argument), some time when i try to open the template (run time error 9: subscript out of range).Did someone have the same problem? I saw a forum specking about librfc.dll file, but i couldn't find many details.
    Thanks.
    Valentina

    hi V.,
    support package level for front end 3.5 ?
    you can check in bex, 'business explorer'->help->about.
    the info version 3500.x.yy; x is the support package level.
    i have tried to use front end 3.5 to access bw 3.0, WAD open like to errors, after patch 7 applied, seems ok.
    you may try with front end 3.0b
    hope this helps.

  • Run time error in report for a particular month : "  TIME_OUT"

    hi frends, we have developed a report for PM module in SAP. it is a monthy report. and user have to enter the month for which he wants to see the report. we are facing runtime error for a particular oct. and nov month of 2009 only , all other months are working fine. The error is :
    The program "ZPMR_EQUP_PERFORMANCE_REPORT" has exceeded the maximum permitted
      runtime without
    interruption and has therefore been terminated.
    what could be the reason.

    Hi  Achalmehra,
    By seeing the run time error "TIME_OUT", I suspect this is due to Performance issue.
    There is a chance that they had huge data dump into PM server from other servers and there is also chance that
    They have many records available for these 2 months.
    IN any case, please chk with Run time analysis (SE30) by executing your program...
    If it displays the graph more than 30 % for Database then it is an issue with the Performance.
    Also chk with SQL trace.....
    Second case :
    Check you had not used Nested Loops,  Select queries in Loop.
    Make sure you use Binary search for  Read Statements....
    Third : Chk with the runtime error at which place of the code it is throwing Time_out error at Source code extract.
    To help you further, please paste your code here and also paste the Run time error that you receive with the select queries.
    Regards,
    Kittu

  • ABAP run time error in Plant Maintenanace

    hi experts,
    i am creating order for external service with control key PM03,
    I've done all required configuration and 12 orders were created also,but now ABAP run time error occurs,
    Short text
    with short text description
    Exception condition "RECORD_NOT_FOUND_TCK01" raised.
    i called up ABAP consultant,he told me to check all field and configuration,and am not able to pin point sources of error,
    please  guide for this,
    thanks
    Edited by: Pravin on Oct 20, 2008 11:58 AM

    Dear Praveen,
    I think your problem may be space of hard disk.11 records created succesfully and 12 record was creation problem.in thease reasons may be problem is table space in hard disk.
    you ask first basis guys to check the data storage space and kindly run the sgen
    Hope this may helps you
    Prem.

  • Not able to open PDF or do any changes even if the PDF opens. Run Time Error is shown every time when trying to open PDF. Please help

    Hi,
    Not able to open PDF or do any changes even if the PDF opens. Run Time Error is shown every time when trying to open PDF. Please help

    Hi Shilpa ,
    Please refer to the following link and see if that helps you out.
    https://helpx.adobe.com/acrobat/kb/runtime-error-roaming-profile-workflows.html
    Are you trying to access the PDF with Acrobat or Adobe Reader?
    Regards
    Sukrit Dhingra

  • Run-Time Error '6' Overflow within BEx Analyzer after copy/paste query

    Hi all,
    User is getting a "Run-time error '6' overflow" message which is caused after copying any query in a 'query pack' to any free row/column within the same sheet (BEx Analyzer). This "query pack" has multiple queries within one sheet and covers 1800 rows so there is enough free space left for copying one of the queries to another position in the same sheet.
    Microsoft Office Excel SP2 is used which is part of MS Office professional edition 2003. The BW version is 3.0.
    Please let me know if more details are required or above mentioned error message is recognized and can be explained.
    Thanks and kind regards,
    Raymond Flaton

    Hi VRV,
      This error is caused whenever there is memory issue. If your query is built on a cube which has a BWA index then this problem can be related to the issue with the BWA server. Check your BASIS team to check if there is memory issue presently in the BWA server.
    Sometimes the issue is temporary, where the several users accesing the reports to fetch data from BWA lead to this type of error as the BWA gets overloaded. Try exiting the report and run it after some time again.
    Alternatively you can also try restricitng the selection for fetching the data in the report as suggested.
    Thanks

  • Bex : Run-time Error '13' - Type Mismatch

    Dear,
    I have a trouble with BEX. With some user, they can not start BEX.
    When They start BEX, they have the Run-Time Error '13'  type mismatch.
    With a administrator account, we have not problem.
    When I go in the debug, it stop on "addIn.RunAutoMacros (xlAutoOpen)"
    Could you help me ?
    Thank you,
    Philippe Dupriez

    Phillipe, did you solve this issue. I have a similar issue
    AddIn.RunAutoMacros(xlAutoOpen).
    I appreciate your reply.
    Thanks,
    Parvathi.

  • Run time error when Combining PDF or WORD files

    Good morning everyone
    I have a client who is trying to merge two files either word or PDF files and every time she does this she is getting a run time error on the process.
    the Machine is a Lenevo Desktop with Xp SP3 on the machine
    Running Office 2007 with SP 3 now on the machine
    Adobe Pro X with the latest and current updates Licnesed
    I have done the repair on this unit several times as well as repair of the Office. 
    We can convert the Word files no problem but i get a an error on the merging of the files
    has anyone seen this problem before?
    what do i need to do to resolve this issue?

    Operating system is Windows Vista Home Premium..
    Version of Adobe Reader is 10.1.13.
    Any thoughts on what the issue is?

  • Package failed with run time error: " GETWA_NOT_ASSIGNED".

    Hi,
    One of our custom package is failing with run time error " GETWA_NOT_ASSIGNED". We are getting this error after refresh. Infact this package is working fine both in production and Dev, but in QA system it giving runtime error.
    Here with I am pasting run time error details. Please see...If any one have any idea or clue or if you have faced this kind of error.
    Thanks is advance.
    Error Details.
    What happened?
        Error in the ABAP Application Program
        The current ABAP program "CL_UJK_CUSTOM_LOGIC===========CP" had to be
         terminated because it has
        come across a statement that unfortunately cannot be executed.
    What can you do?
        Note down which actions and inputs caused the error.
        To process the problem further, contact you SAP system
        administrator.
        Using Transaction ST22 for ABAP Dump Analysis, you can look
        at and manage termination messages, and you can also
        keep them for a long time.
    Error analysis
        You attempted to access an unassigned field symbol
        (data segment 32774).
        This error may occur if
        - You address a typed field symbol before it has been set with
          ASSIGN
        - You address a field symbol that pointed to the line of an
          internal table that was deleted
        - You address a field symbol that was previously reset using
          UNASSIGN or that pointed to a local field that no
          longer exists
        - You address a global function interface, although the
          respective function module is not active - that is, is
          not in the list of active calls. The list of active calls
          can be taken from this short dump.
    Regards, Trine

    Hi Trine,
    the error is about some field you are trying to map using field-simbols, that is diferent in the other system.
    Go to the code program in the st22, there you will see when the erros occurs e what field gives the error.
    Best Regards,
    António

  • Run Time Error When opening PDF File on Computer

    I am getting a run time error when I try to open up PDF's on my computer.  The error message reads, "The application has requested the runtime to terminate in an unusual way.  When I click ok the error box I get a message that says adobe reader has stopped working and the program has been closed.  FYI I am using the latest version of adobe reader

    Operating system is Windows Vista Home Premium..
    Version of Adobe Reader is 10.1.13.
    Any thoughts on what the issue is?

  • ABAP/4 run time error with error code  SNAP_NO_NEW_ENTRY

    Dear All,
               I've installed SAP R/3 IDES on Oracle on Windows 2003 server.After clicking Log on button , I should be asked to enter client,user and password.But, my system does not display such details.Instead I get ABAP/4 run time error with error code  SNAP_NO_NEW_ENTRY that too after a long time.
                Can you please address what is the reason for this problem and how to over ride it?
    Regards,
    S.Suresh

    Hi,
    the most probable reason is an archiver stuck. Backup the archived redo log files and delete them afterwards.
    The database will archive some more logs after this. Handle them in the same manor. For complete explanation search for brtools.
    Regards
    Ralph Ganszky

  • System is giving ABAP run time error while perform LT06 or create TO with r

    Hi SAP WM Gurus,
    System is giving ABAP run time error while perform LT06 or create TO with respect to posting change notice, below are runtime analysis details.
    Short dump has not been completely stored. It is too big.
    P_MENGA = P_MENGE.
    007940       P_UMREZ = 1.
    007950       P_UMREN = 1.
    Can you give any idea on this issue.
    Thanks and Regards,
    SHARAN.

    Hi,
    Go to Tcode ST22 and mentione the dump code there and check.
    Also take help[ of Abapers to fix it.
    Thanks
    Utsav

  • ABAP run time error while perform LT06 or create TO with respect to posting

    Hi SAP WM Gurus,
    System is giving ABAP run time error while perform LT06 or create TO with respect to posting change notice, below are runtime analysis details.
    >> Short dump has not been completely stored. It is too big.
    >       P_MENGA = P_MENGE.
    007940       P_UMREZ = 1.
    007950       P_UMREN = 1.
    Can you give any idea on this issue.
    Thanks and Regards,
    SHARAN.

    This part is just the place in the program where the error occured, but why the error occured is mentioned earlier in the dump.
    Maybe you have a too big number in the field and hence a field overflow, maybe you have a character instead of a number in the field.
    Read the dump from the beginning. if you dont know how to read a dump,then try to get help from any local Abaper.

Maybe you are looking for

  • Display adapter causing bsod

    hellloo I am currently trying to fix my bsod issue with my evny dv6 64bit running windows 8 (16gb RAM, intel i7 8 cores), which has been happening since the first month I got it, for many different reasons. Updating drivers and such has fixed a lot,

  • Setting focus in a PDF form

    Hi, I'm trying to move a cursor to a particular field based on certain conditions using JavaScript. The method I am using is xfa.host.setFocus("fldTest"); in the initialize event. For some reason the focus isn't getting set to fldTest, but when I fir

  • How do I get Thunderbird to turn E-mail addresses blue?

    I am used to the E-mail addresses automatically turning blue, in some case underlined. Can Thunderbird do this? If so, How? Chris Previously Incredimail.

  • Using Command Line to move objects from one environment to another enviroment

    Can the Command Line (sacmd) be used to move Job Groups/Jobs and other object from one environment to another environment? If so, how?

  • Save for Web Matte Not Working?

    Hi everyone, I'm having problems with the Matte settings in the Save for Web section to create a smooth transparent .gif image. None of the black matte is showing up in the zoomed preview (picture attached), nor is it saving when I render the file. T