Runtime error in enhancement spot-' mereq_topline does  not exists.'

Hi all,
I have implemented an implicit enhancement spot in ME53n.
When i applied break point in enhancement spot and control goes to ebhancement spot in debugging mode, i got purchse requisition number in mereq_topline.
When i tried to use this structure value in code i get runtime error-
' mereq_topline does  not exists.'
Can you please guide how to resolve  this runtime error.
thanks.
Edited by: Sanjay_lnt on Sep 20, 2010 8:52 AM

Sanjay,
try to delete the enhancement and recreate it
Thanks
Bala Duvvuri

Similar Messages

  • Error 1070023 Configured Disk volume does not exist.

    Hi
    I installed Essbase 11.1.1.2 in stand alone mode. When I am trying to start Sample.Basic, I am getting the below error
    Error 1002097 Unable to load database Basic.
    The App log showed the following error
    Error 1070023 Configured Disk volume does not exist.
    Please help..

    So everything works when the volume is set to E?
    If so, you might be able to use DISKVOLUMES E in the essbase.cfg file which sets a default (for BSO cubes, at least), but you shouldn't have to do that.
    The DISKVOLUMES documentation says that the volume that contains your ARBORPATH is the one used by default. Not completely sure I trust that it's up to date, and isn't now ESSBASEPATH or something else, but regardless, do those variable all look to be set correctly? To be honest, that's a longshot, as I'd be surprised if a missing / incorrect value there wouldn't cause bigger problems...

  • Error 1075: The dependency service does not exist or has been marked for deletion

    Windows 7 Pro laptop will not connect to corporate domain. Multiple identical twin laptops have no problem.
    Best suggestion so far has been to leave the domain and rejoin it, BUT the relevant buttons are grayed out and the comment says "Note: The identification of the computer cannot be changed because:- The Workstation service is not running. Open the Services
    snap-in (services.msc) to ensure it is running and set its Startup Type as "Automatic"."
    In services.msc the Workstation service is already set to Automatic but is not started. When I try to start it manually the response is "Windows could not start the Workstation service on Local Computer." and then "Error 1075: The dependency service does
    not exist or has been marked for deletion."
    Rebooting gets me nowhere.
    In all other respects that laptop appears fine and can connect to the Internet, but NOT to the network. I have brought it and a twin laptop home to try on my domestic network and get the same results.
    Any ideas, please?

    Hi,
    Let us go to services.msc and navigate to Network Store Interface Service. Please check whether this service has been set to Automatic and turned on.
    Kim Zhou
    TechNet Community Support

  • SCCM 2012 R2 reporting error: "The DefaultValue expression for the report parameter 'UserTokenSIDs' contains an error: A specified logon session does not exist. It may already have been terminated. (rsRuntimeErrorInExpression)"

    Hi,
    I have two SCCM environments under same active directory domain and one service account have been used for SCCM configurations on both the environments (QA and PRODUCTION). I am facing similar error as mentioned above while trying to fetch reports on
    PRODUCTION site, but the QA site is working fine, though same service account have been used for configuring both. While looking at the reportserverservice_<date> log on my Production DB server i see the following error
    "processing!ReportServer_0-3!2124!01/02/2015-09:09:30:: e ERROR: Throwing Microsoft.ReportingServices.ReportProcessing.ProcessingAbortedException: , Microsoft.ReportingServices.ReportProcessing.ProcessingAbortedException: An error has occurred during
    report processing. ---> Microsoft.ReportingServices.ReportProcessing.ReportProcessingException: Cannot read the next data row for the dataset DataSet1. ---> System.Data.SqlClient.SqlException: Conversion failed when converting the nvarchar value 'Override
    Default' to data type int."
    My DB and SCCM primary site are different and the reorting services point is installed on remote DB server. Please help me resolving the issue.
    Troubleshooting performed:
    1.Disabled the registry key 'EnableRbacReporting' from HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\SMS\SRSRP to 0 and then restarted SSRS service and the reporting worked for some minutes after that the registry key reverted back to 1 automatically and
    reporting started throwing errors again.
    2. Checked with the permissions on DB whether or not 'sysadmin' role is assigned to the SCCM service account.
    3. re-registered the SQL management Provider WMI class.
    mofcomp.exe “C:\Program Files (x86)\Microsoft SQL Server\110\Shared\sqlmgmproviderxpsp2up.mof”

    Hi All,
    Finally found exact solution to the reporting error.
    Error: while launching SCCM reports (both from Console and web based) an unexpected error occured with error message as "The DefaultValue expression for the report parameter ‘UserTokenSIDs’ contains an error: A specified logon session does not exist.
    It may already have been terminated. (rsRuntimeErrorInExpression)"
    Solution: This is password replication issue for the domain account used to configure reporting services point in SCCM. If your SQL SSRS reporting services instance and databse runs with local default account whereas the reporting services point on SCCM
    primary site is configured with domain account, (As in My case) you need to perform the following in order to get rid of the error.
    Launch 'Reporting Services Configuration Manager' from the SQL SSRS box(either Local or Remote), Connect to Report Server Instance->Go to 'Execution Account' tab->Specify the 'Execution Account' as domain account and password which is used to configure
    Reporting Services Point in SCCM Primary Site, and then click apply.
    Now Lauch the report either way (Web based or from Console), the error will disappear and all your default reports will execute perfectly as before.

  • Error MSB4057: The target "PlatformPrepareForBuild" does not exist in the project._

    Hi to all,
    I tried to compile my .sln with VS2010 but I had this error.
    error MSB4057: The target "PlatformPrepareForBuild" does not exist in the project.
    It occurs only compiling with win32 configuration but not with x64 one.
    Ideas?
    Thank you in advanced

    In which version of Visual Studio did you create this solution? And What type of the project in this solution? And could you please post the proj file here?
    If this solution is created in VS2012 or VS2013, please make sure the original solution is not corrupt, it can be opened and built successfully in the corresponding Visual Studio. For probable compatibility issues, you could check the documents here:
    Visual Studio 2012 Compatibility
    Visual Studio 2013 Compatibility
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click
    HERE to participate the survey.

  • Part of Photoshop isn't functioning.  Under adjustments, when HDR toning is clicked on I get a code:  Error 48: File or folder does not exist.  Line:11  - $.evalFile(g_StackScriptFolderPath   "StackSupport.jsx");  How can it be fixed?

    The phone company was here working on something while I was gone.  They sat down at my computer (iMac) and since then HDR toning doesn't work.  Get the code:   Error 48: File or folder does not exist.    Line: 11     ->  $.evalFile(g_StacScriptFolderPatch + "StackSupport.jsx");   How can this be fixed?   

    Go to //Applications/Adobe Photoshop [Version]/Presets/ Scripts/Stack Scripts Only/ and see if StackSupport.jsx is there. If it is not, uninstall and reinstall Photoshop to have it added back in. If it is there, first try recreating the Photoshop Preferences (hold down Command+Option+Shift while launching Photoshop).

  • HDR Toning Error 48: File or Folder Does Not Exist

    After migrating to a new computer HDR Toning is no longer available.
    I get a pop-up: Error 48: File or Folder Does Not Exist
                             Line 11  -> $. evalFile(g_StackScriptFolderPath + "StackSupport.jsx");
    What's the fix for this, if anyone knows?
    Thanks.

    Go to //Applications/Adobe Photoshop [Version]/Presets/ Scripts/Stack Scripts Only/ and see if StackSupport.jsx is there. If it is not, uninstall and reinstall Photoshop to have it added back in. If it is there, first try recreating the Photoshop Preferences (hold down Command+Option+Shift while launching Photoshop).

  • Ruler Tool- Error 48: File or folder does not exist

    I am trying to use the new RULER TOOL in CS5 (64-bit mode) running 10.6.4 and I get the following error:
    Error 48: File or folder does not exist.
    Line: 31
    ->  $.evalFile( g_StackScriptFolderPath + "Geometry.jsx");
    Any ideas?

    i'm getting the exact error using Windows XP with CS5.5
    error 48: file or folder does not exist
    line: 31
    -> $.evalFile(g_StackScriptFolderPath + "Geometry.jsx");
    HELP!!!
    someone
    hello ... anyone out there?
    how do we get support for this error?
    e

  • Error message FI 759: Fund does not exist in FM area

    Hill!
    I have to make a distribution in CO-OM (tr KSV5) according to fund
    But if I customize fund as sender, choose fund from the fund catalog  and make a formal chek of cycle I see an error message FI 759: Fund does not exist in FM area. How can I make it go away?

    Hi Irina,
    As per the note 489315, you must choose a layout that contains the exact data for the active objects.
    When planning for non-FM company codes you will have to change the profile/layout that only contain the elements that are active in the company code.
    If you encounter error: KAFF002 while doing the above then please can you see if point 3 of note 555134 will help to by-pass the message.
    Once you add the field Fund and set it to optional you should be able to use planning.
    Note 555134:
    3.  The fields of the Funds Management are defined as 'Required entry
        fields' in the standard layouts, in other words depending on the
        permissibility of the initial value for a field an entry is always
        demanded. To prevent this there are two options:
        a) Copy the desired standard layout into an own (transaction KP65,
           KPG5, OPO1) and via "Extras -> Variables -> Variables definition'
           set the corresponding field to 'Optional". Then, add this layout
           to your planner profile with transaction KP34.
        b) Implement the attached program ZK555134 (correction instruction
           461025). After the entry of planning area and layout all fields
           of the Funds Management are set depending on your selection of
           'Optional' or 'Not optional' (standard system). Like this you can
           also change standard layouts. The check for the fields for which
           'initial' is not a valid value is still carried out.
    If you want to use FUND Accounting, I suggest you to read note 518610 for your reference. This note contains information about FUND Accounting and its effect.
    If you only want to use 'Fund' in Funds Management, you do not have to activate the 'Fund' account assignment element.
    If you activated the FUND account assignment element, which is at CLIENT level activation, the fund would always have to be filled as a required  entry field in CO, FI-AA and HR for all company codes in the client concern.
    Please also refer to notes 625262 and 659086.
    or re-import the standard planning layout from the client 000. In the note 320197 is descriped how to do this.
    I believe this will resolve your issue.
    Best Regards,
    Vanessa.

  • Error(27,78): Reference PartnerLink1 does not exist as wire target

    I am starter to BPEL.. when i am trying to invoke webservice(http://www.webservicex.net/convertMe...ight.asmx?WSDL) i am getting these errors
    Error(27,78): Reference PartnerLink1 does not exist as wire target
    Error(90): Element 'targets' not expected.
    Edited by: 974508 on Dec 2, 2012 8:09 PM

    maybe you first created the partnerlink in the bpel instead of the composite?
    create the reference in the composite, see if you get the wire from the bpel to your convert-service and then go to the bpel process and use the invoke to call the partnerlink
    if you did all this (recreating the service in the composite would maybe be the easy fix)

  • Build error :package com.sun.javadoc does not exist

    Question from a Turing machine expert who is new to Java.
    Trying to run a sample program from Richardson's book "Java JDK 5 Edition" Chapter 1.
    In Netbeans 5.5 receive build error :package com.sun.javadoc does not exist
    for "import com.sun.javadoc.*;"
    Believe missing classes are in tools.jar in C:\Sun\SDKee5SDK\jdk\lib
    How do I define this to Netbeans and/or JDK?
    Using java_ee_sdk-5_01
    and netbeans-5_5-windows downloads.
    Platform is XP.
    Netbeans has been updated to date.
    Appreciate.

    sony_tj wrote:
    D:\Xyz.java:22: package com.sun.javadoc does not exist
    import com.sun.javadoc.*;After getting this error, I have set my classpath to C:\Program Files\Java\jdk1.5.0_03\lib\tools.jar. But still the error persists. Could anyone please tell me how do I solve this problem.You have failed in setting your classpath in that case.

  • Build Question: error 7 occurred at source does not exist

    I have VIs built in LabVIEW 6.1. It works and built well. In LabVIEW
    7, It works well. But when I try to build it. I got error.
    I first use the mass conpile to compile VIs and then build the exe
    with default settings. I got:
    Error 7 occurred at source does not exist
    Possible reason(s):
    LabVIEW: File not found. The file might have been moved or deleted,
    or the file path might be incorrectly formatted for the operating
    system. For example, use \ as path separators on Windows, : on Mac OS,
    and / on UNIX.
    NI-488: Non-existent board.
    But It does not point out which file does not exist.
    Anyone can help me out?

    Hello yqin,
    Here are some more KnowledgeBases that may pertain to your issue.
    Error 7 When Building Applications and DLLs That Use the LabVIEW Report Generation Toolkit
    Why Do I Get Error 7 When Building an Executable from a Build Script?
    Error 7 at Invoke Node When Building a LabVIEW Executable
    If the above KnowledgeBases do not work, we will want to try the following procedure.
    1. Open your Main VI.
    2. Hold + a
    nd click the run arrow (forces recompile).
    3. Close the VI and mass compile it.
    4. Keep the VI closed and build the application from scratch (do not use a script).
    5. Ensure that all VIs called dynamically are included as support files before building.
    Please let me know if you have any questions,
    Matt
    Keep up to date on the latest PXI news at twitter.com/pxi

  • Error 7 occurred at source does not exist

    I have VIs written in LabVIEW 6.1 and works fine. I try to use LabVIEW 7 to build it. But I got error:
    Error 7 occurred at source does not exist
    Possible reason(s):
    LabVIEW: File not found. The file might have been moved or deleted, or the file path might be incorrectly formatted for the operating system. For example, use \ as path separators on Windows, : on Mac OS, and / on UNIX.
    NI-488: Non-existent board.
    Application Builder: Error copying files.
    It does not point out which file is not exsisted? Why?

    Hello �
    From your question, I understand that you are trying to build an executable for LabVIEW 7.0 of some VIs that were built in LabVIEW 6.1.
    You need to save all the VIs and subVIs that will be contained in the executable (or DLL) in LabVIEW 7.0 first. For this, the only thing you need to do is to open them in LabVIEW 7.0 and re-save them. If you want to keep copies for both versions of LabVIEW, you could even create a different folder for the version 7.0 ones. When re-saving your VIs just go to File >> Save As and browse to the directory you just created.
    Then, you will be able to build the executable for LabVIEW 7.0.
    Another possible solution to the problem is what is mentioned in this 5F09C86256745006E4494?OpenDocument>Knowledgebase.
    Hope this helps!
    S Vences
    Applications Engineer
    National Instruments

  • FTXP-error-Domain MWART fixed value  does not exist- Message no. F4341

    Hi,
    I am trying to created a new record for a tax code, and i get this error
    Domain MWART fixed value  does not exist
    Message no. F4341
    I looked up OB40, and not sure how to fix this. Do you know how to check the tax codes? How to validate OB40?
    Thanks.

    Hello,
    Please follow this procedure for the input tax codes which experience
    the error F4341:
    1) Go to SE16 and enter table T007A
    2) Hit enter and in the next screen choose the following parameters
       and enter values that represent the tax code for input tax which are
       encountering the problem.
       KALSM (tax procedure)
       MWSKZ (tax code)
    3) Click on the "execute" button.
    4) Take special attention to column MWART which represents tax type.
       This should only have a value "V" to represent input tax (or "A" if
       output tax).
    5) The cause of the error F4 341 is when this column does not contain
       any value or is blank.  Which means that there is no defined tax type
       "A" or "V" maintained in customizing.
    6) To correct this you should maintain the value again via FTXP for the
       corresponding tax codes and complete all the customizing settings
       relating to tax on sales and purchases thereunder. Afterwhich you
       should no longer experience the error message.
    Regards,
    REnan

  • Standard Data Collection Failing with Error ORA-04054: database link  does not exist.

    Hi Gurus,
    When I am running Standard Data Collection in ASCP(APS) instance R12.1.3, its failing with error : ORA-04054: database link  does not exist.
    There is no such Database link exits which is showing in above error.
    Also the database link name in the above error is not profile values in the database.
    I think, concurrent might be fetching this database link name  from some tables related to plan.
    I am not having much knowledge about how this ASCP/APS works.
    Need your help to resolve this issue.
    Thanks,

    Hi,
    ASCP Collections looks at the dblink from instances definitions from.
    1. Responsibility: Advanced Planning Administrator
    2. Navigation: Admin > Instances
    You may review the note in support.oracle.com - Understanding DB Links Setup for APS Applications - ASCP and ATP Functionality (Doc ID 813231.1)

Maybe you are looking for

  • PC won't recognize iPod

    My daughter is going off to college and I'm trying to install her new iPod on a new Toshiba PC laptop. I've installed and uninstalled and reinstalled all of the software way too many times (why couldn't she use a mac at college). Anyways, the last ti

  • Ipod cant connect and can't play songs

    Hi guys, hope u can help. My ipod stopped working last night for no appernet reason (comes up with the apple ogo then goes to folder icon with www.apple.com/support/ipod below it). I've tried installing itunes and updater but can't connect to the ipo

  • Calendar: why can't I get time 30.03.2003 02:00:00?

    Why can't I display the date/time 30.03.2003 02:00:00?? See code example below. When I put these values in Calendar the system displays "Sun March 30 01:00:00 CEST 2003. The date is correct but time is wrong. Hour 02 is skipped and hour 01 is display

  • Issue in stock category

    hi,   i am posting gr.po in migo for x- material as 10 quantity then TR is created automatically with stock category as "Q" after quality inspection once i put TO for that material the stock category as "Q" not as available stock . my requirement is

  • Object Browser crashing??

    Hello all. Has anyone seen where you try to view items in the object browser by selecting the object type in the pull down menu, and no matter what you select, the browser window automatically closes? It just started exibiting this behavior and I hav