SAN Port-Channel between Nexus 5000 and Brocade 5100

I have a Nexus 5000 running in NPV mode connected to a Brocade 5100 FC switch using two FC ports on a native FC module in the Nexus 5000. I would like to configure these two physical links as one logical link using a SAN Port-Channel/ISL-Trunk. An ISL trunking license is already installed on the Brocade 5100. The Nexus 5000 is running NX-OS 4.2(1), the Brocade 5100 Fabric OS 6.20. Does anybody know if this is a supported configuration? If so, how can this be configured on the Nexus 5000 and the Brocade 5100? Thank you in advance for any comments.
Best regards,
Florian

I tried that and I could see the status light on the ports come on but it still showed not connected.
I configured another switch (a 3560) with the same config and the same layout with the fiber and I got the connection up on it. I just cant seem to get it on the 4506, would it be something with the supervisor? Could it be wanting to use the 10gb port instead of the 1gb ports?

Similar Messages

  • Issues with a port-channel between Nexus 5K and 4506

    I'm having some trouble configuring an up-link from a Cisco 4506 to a set of Nexus 5k switches and cannot get either side to recognize the media. My configuration is as follows...
    Nexus 5k
    interface Ethernet1/22
      description ## 1A ##
      switchport mode trunk
      switchport trunk native vlan 150
      speed 1000
    Cisco 4506
    interface GigabitEthernet1/6
     switchport trunk encapsulation dot1q
     switchport trunk native vlan 150
     switchport mode trunk
    I am using 1gb sfp's (GLC-SX-MM) and I have verified that the fiber cables I am using and the fiber between closets is in working condition. But I cannot get the interface to come up. 

    I tried that and I could see the status light on the ports come on but it still showed not connected.
    I configured another switch (a 3560) with the same config and the same layout with the fiber and I got the connection up on it. I just cant seem to get it on the 4506, would it be something with the supervisor? Could it be wanting to use the 10gb port instead of the 1gb ports?

  • SAN Port Channel between 6120 and Brocade

    Has anyone setup or know how to setup a SAN Port Channel between 6120s and a Brocade FC switch? I know that it requires UCS firmware 1.4 but I don't know what the Brocade requirements are.

    The SAN port channel is Cisco proprietory. You cannot setup SAN port channel with Brocade. Sorry

  • Port channel between Nexus and Server is initializing

    Hi all, 
    I will need your help. 
    I have Nexus 5000, there is a POrt Channel between Nexus and Server, but one port always is in initializing.
    sh interface Ethernet101/1/27
    Ethernet101/1/27 is down (initializing)
      Hardware: 1000/10000 Ethernet, address: c8f9.f920.5b5c (bia c8f9.f920.5b5c)
      MTU 1500 bytes, BW 10000000 Kbit, DLY 10 usec
      reliability 255/255, txload 1/255, rxload 1/255
      Encapsulation ARPA
      Port mode is trunk
      auto-duplex, 10 Gb/s, media type is 10G
      Beacon is turned off
      Input flow-control is off, output flow-control is on
      Rate mode is dedicated
      Switchport monitor is off
    Any idea?
    Regards

    how many ports are you using in this port channel.
    can you paste the configuration of the channel ports and the interface.
    check the sh log if you are getting any log related to the port channeling.

  • Create port channel between UCS-FI and MDS 9124 (F Mode)

    Dear Team,
    We were trying to create  port channel between UCS FI and MDS 9124
    But the port channel not getting active in F mode on MDS 9124
    FI is in FC End Host Mode
    We have enabled FC uplink trunking on FI
    We have enabled NPIV on MDS
    We have enabled trunk on MDS
    FI and MDS in default VSAN
    To check we changed the FI mode to FC Switching mode and port channels became active but in E mode
    when we enabled FC uplink trunking on FI and FC Switching mode port channels became active in TE mode
    but in both the above cases showflogi database shows WWPN of SAN alone not showing any from FI.
    How to achive this?
    Have read that no need to change the swicthing mode to FC Switching mode and keep as FC Endhost mode
    SO how to achieve Port channel with F mode in MDS and FI ( Mode showing as NProxy)
    Does it has to do anything with MDS NX-OS version? (https://supportforums.cisco.com/thread/2179129)
    If yes how to upgrade as license for ports came along with Device and we do not have any PAC/PAK or license file as it came
    with license
    Also we have seen 2 files availabe for download (m9100-s2ek9-kickstart-mz.5.2.8b.bin and m9100-s2ek9-mz.5.2.8b.bin) which to use
    Thanks and Regards
    Jose

    Hi Jo Bo,
    what version of software if your MDS running?
    On your UCS do connect nxos and show inteface brieft and look at the mac address.
    it is possible that you might be hitting the bug below. if this is the case you might need to upgrade the firmware on your MDS.
    Add MAC OUI "002a6a", "8c604f", "00defb" for 5k/UCS-FI
    http://tools.cisco.com/Support/BugToolKit/search/getBugDetails.do?method=fetchBugDetails&bugId=CSCty04686
    Symptom:
    Nexus switch unable to connect any other Nexus or other Cisco Switch in NPV mode with a F port-channel.   Issue might be seen in earlier 5.1 releases like
    5.1.3.N1.1a
    but not the latest
    5.1.3.N2.1c
    release. Issue is also seen in
    5.2(1)N1(1)
    and
    6.0(2)N1(1)
    and later releases.
    Conditions:
    Nexus configured for SAN PortChannels or NPIV trunking mode Nexus connected to UCS via regular F port channel where UCS in NPV mode  NPV edge switch: Port WWN OUI from UCS FI  or other Cisco manufactured switch:  xx:xx:00:2a:6a:xx:xx:xx   OR  xx:xx:8c:60:4f:xx:xx:xx
    Workaround:
    Turn-off trunking mode on Nexus 5k TF-port Issue does not happen with standard  F-PORT Remove SAN Portchannel config
    Further Problem Description:
    To verify the issue please collect  show flogi internal event-history errors  Each time the port is attempted OLS, NOS, LRR counters will increment. This can be determined via the following output,  show port internal info all show port internal event-history errors

  • Configure port channel between IO Module and FI

                       Hi,
    I have the current setup
    UCS chassis (4 uplinks) --> FI --> (Port channel) --> N5K --> (port channel) --> VSS 6500
    I configure port channel between IO Module and the FI by changing to policy to "Port Channel" and set the link to 4
    FI has created a portchannel under "Internal" containing all the FI interfaces that are connected to the IO module.
    I have installed ESXI on a blade but i was unable to reach it, even the esx was unable to ping the gateway.
    VLAN tagging is enabled from the ESX server.
    I have issued the command "show mac address-table | inc <mac address of the vnic assigned from thre service profile> on both the N5K and thr 6500 and the mac is there.
    I have allowed all the vlans on the vNIC from the service profile.
    am I missing anything?
    thanks

    Hello,
    Can you please check whether your ESXi vmkernel interface ip address learned on right VLAN on FI / upstream switch or not.
    connect nxos
    show mac-address-table | inc 
    Padma

  • UCS FI 6248 to Nexus 5548 San port-channel - not working

    Hi all,
    I'm sure I am missing something fairly obvious and stupid but I need several sets of eyes and help.
    Here is the scenario:
    I want to be able to create san port-channels between the FI and Nexus.  I don't need to trunk yet as I can't even get the channel to come up.
    UCS FI 6248:
    Interfaces fc1/31-32
    Nexus 5548
    interfaces fc2/15-16
    FI is in end-host mode and Nexus is running NPIV mode with fport-channel-trunk feature enabled.
    I'm going to output the relevants configurations below.
    Nexus 5548:
    NX5KA(config)# show feature | include enabled
    fcoe                  1         enabled
    fex                   1         enabled
    fport-channel-trunk   1         enabled
    hsrp_engine           1         enabled
    interface-vlan        1         enabled
    lacp                  1         enabled
    lldp                  1         enabled
    npiv                  1         enabled
    sshServer             1         enabled
    vpc                   1         enabled
    interface san-port-channel 133
      channel mode active
      no switchport trunk allowed  vsan all
      switchport trunk mode off
    interface fc2/15
      switchport trunk mode off
      channel-group 133 force
    no shutdown
    interface fc2/16
      switchport trunk mode off
      channel-group 133 force
    no shutdown
    NX5KA# show vsan membership
    vsan 1 interfaces:
        fc2/13            fc2/14          
    vsan 133 interfaces:
        fc2/15            fc2/16            san-port-channel 133
    vsan 4079(evfp_isolated_vsan) interfaces:
    vsan 4094(isolated_vsan) interfaces:
    NX5KA# show san-port-channel summary
    U-Up D-Down B-Hot-standby S-Suspended I-Individual link
    summary header
    Group  Port-      Type    Protocol               Member Ports
           Channel
    133    San-po133  FC      PCP      (D)  FC       fc2/15(D)    fc2/16(D)   
    UCS Fabric Interconnect outputs:
    UCS-FI-A-A(nxos)# show san-port-channel summary
    U-Up D-Down B-Hot-standby S-Suspended I-Individual link
    summary header
    Group  Port-      Type    Protocol               Member Ports
           Channel
    133    San-po133  FC      PCP      (D)  FC       fc1/31(D)    fc1/32(D)   
    UCS-FI-A-A(nxos)#
    UCS-FI-A-A(nxos)# show run int fc1/31-32
    !Command: show running-config interface fc1/31-32
    !Time: Fri Dec 20 22:58:51 2013
    version 5.2(3)N2(2.21b)
    interface fc1/31
      switchport mode NP
      channel-group 133 force
      no shutdown
    interface fc1/32
      switchport mode NP
      channel-group 133 force
      no shutdown
    UCS-FI-A-A(nxos)#
    UCS-FI-A-A(nxos)# show run int san-port-channel 133
    !Command: show running-config interface san-port-channel 133
    !Time: Fri Dec 20 22:59:09 2013
    version 5.2(3)N2(2.21b)
    interface san-port-channel 133
      channel mode active
      switchport mode NP

    !Command: show running-config interface san-port-channel 133
    !Time: Sat May 16 04:59:07 2009
    version 5.1(3)N1(1)
    interface san-port-channel 133
      channel mode active
      switchport mode F
      switchport trunk mode off
    Changed it as you suggested...
    Followed the order of operations for "no shut"
    Nexus FC -> Nexus SAN-PC -> FI FC -> FI SAN-PC.
    Didn't work:
    NX5KA(config-if)# show san-port-channel summary
    U-Up D-Down B-Hot-standby S-Suspended I-Individual link
    summary header
    Group  Port-      Type    Protocol               Member Ports
           Channel
    133    San-po133  FC      PCP      (D)  FC       fc2/15(D)    fc2/16(D)
    NX5KA(config-if)#
    Here is the output as you requested:
    NX5KA(config-if)# show int san-port-channel 133
    san-port-channel 133 is down (No operational members)
        Hardware is Fibre Channel
        Port WWN is 24:85:00:2a:6a:5a:81:00
        Admin port mode is F, trunk mode is off
        snmp link state traps are enabled
        Port vsan is 133
        1 minute input rate 1256 bits/sec, 157 bytes/sec, 0 frames/sec
        1 minute output rate 248 bits/sec, 31 bytes/sec, 0 frames/sec
          3966 frames input, 615568 bytes
            0 discards, 0 errors
            0 CRC,  0 unknown class
            0 too long, 0 too short
          2956 frames output, 143624 bytes
            0 discards, 0 errors
          46 input OLS, 41 LRR, 73 NOS, 0 loop inits
          257 output OLS, 189 LRR, 219 NOS, 0 loop inits
        last clearing of "show interface" counters never
        Member[1] : fc2/15
        Member[2] : fc2/16
    NX5KA(config-if)#
    NX5KA(config-if)# show int brief
    Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                      Mode   Trunk                          Mode  Speed  Channel
                             Mode                                 (Gbps)
    fc2/13     1      auto   on      sfpAbsent        --     --           --
    fc2/14     1      auto   on      sfpAbsent        --     --           --
    fc2/15     133    F      off     init             swl    --           133
    fc2/16     133    F      off     init             swl    --           133

  • FC Port Channel between UCS and MDS.

    Hi All,
    I am new to Cisco Fabric Concepts. In my enviornment i have a F port channel(8 Port Group) created on MDS 9513 switch and this Fport 
    channel is connected to Cisco UCS 6296 FI. The Cisco UCS Blade servers are connected to the Fabric Interconnect .
    On MDS NPIV is enabled.
    Can anyone explain the below questions.
    1. Why do we create an F port Channel Group and connect it to the UCS FI? Is this something similar to Brocade Edge to AG Switch Connectivity.
    2. How to configure F port Channel Group in MDS . Can anyone explain with an example.
    3. Do we need to make any Configuration on UCS FI ports for server connectivity and Channel port Connectivity if yes what are the steps required to 
    do the same.Does the WWPN shows up in the FLOGI Database if the connectivity and configuration looks good in UCS FI and MDS.
    4. What happens when a VSAN on MDS switch is added to the Port Channel.
    Thanks and Regards,
    Santosh surya

    Look at my remarks in
    https://supportforums.cisco.com/discussion/12468266/fc-port-channels-between-mds-and-ucs-fi-best-practice
    1. Why do we create an F port Channel Group and connect it to the UCS FI? Is this something similar to Brocade Edge to AG Switch Connectivity.
    F port channel is proprietary; therefore any such F port channel between UCS FI and Brocade doesn't work.
    2. How to configure F port Channel Group in MDS . Can anyone explain with an example.
    see eg.
    https://supportforums.cisco.com/sites/default/files/legacy/9/9/2/53299-UCS_1-4-1_F-port_channel-trunk-v1.pdf
    3. Do we need to make any Configuration on UCS FI ports for server connectivity and Channel port Connectivity if yes what are the steps required to 
    see eg.
    https://supportforums.cisco.com/sites/default/files/legacy/9/9/2/53299-UCS_1-4-1_F-port_channel-trunk-v1.pdf
    Does the WWPN shows up in the FLOGI Database if the connectivity and configuration looks good in UCS FI and MDS.
    flogi database is on the MDS, not FI; there are however UCS CLI commands, like "show npv ...."
    4. What happens when a VSAN on MDS switch is added to the Port Channel.
    If its not created on UCS, it will just not become the status "up"

  • LACP port channel between 6509 and Nexus 7K

    We are in the process of migrating from dual 6509's to dual 7010's.  We have moved our 5k/2K's behind the 7K and have layer 2 up between the 6509 and 7K.  This link is configured as a port channel with 2 1gig links using LACP.  The port channel is up and working and traffic is passing but it doesn't appear the load it equally distributed between the links.  Both the 7K and 6K are setup for src-dst-ip for the load balancing.  The links have been in place for over 12 hours and I would have expected them to "equal" out.  Has anyone had this issue in or is this to be expected?  For clarification there is not VPC inolved in this configuration it is simply a port-channel between one 6509 and a 7010.
    Thanks,
    Joe

    We are in the process of migrating from dual 6509's to dual 7010's.  We have moved our 5k/2K's behind the 7K and have layer 2 up between the 6509 and 7K.  This link is configured as a port channel with 2 1gig links using LACP.  The port channel is up and working and traffic is passing but it doesn't appear the load it equally distributed between the links.  Both the 7K and 6K are setup for src-dst-ip for the load balancing.  The links have been in place for over 12 hours and I would have expected them to "equal" out.  Has anyone had this issue in or is this to be expected?  For clarification there is not VPC inolved in this configuration it is simply a port-channel between one 6509 and a 7010.
    Thanks,
    Joe

  • FC port channels between MDS and UCS FI best practice?

    Hi,
    We would like to create FC port channels between our UCS FI's and MDS9250 switches.
    At the moment we have 2 separate 8Gbps links to the FI's.
    Are there any disadvantages or reasons to NOT do this?
    Is it a best practice?
    Thanks.

    As Walter said, having port-channels is best practice.  Here is a little more information on why.
    Let's take your example of two 8Gbps links, not in a port-channel ( and no static pinning ) for Fibre Channel connectivity:
    Hosts on the UCS get automatically assigned ( pinned ) to the individual uplinks in a round-robin fashion.
    (1)If you have some hosts that are transferring a lot of data, to and from storage, these hosts can end up pinned to the same uplink and could hurt their performance. 
    In a port-channel, the hosts are pinned to the port-channel and not individual links.
    (2)Since hosts are assigned to an individual link, if that link goes down, the hosts now have to log back into the fabric over the existing working link.   Now you would have all hosts sharing a single link. The hosts will not get re-pinned to a link until they leave and rejoin the fabric.  To get them load balanced again would require taking them out of the fabric and adding them back, again via log out, power off, reload, etc...
    If the links are in a port-channel, the loss of one link will reduce the bandwidth of course, but when the link is restored, no hosts have to be logged out to regain the bandwidth.
    Best regards,
    Jim

  • Nexus 5000 and MDS 9509 FC

    Greetings Everyone,
    I have been beating my head on the desk for the last few days tring to get a FC connection established between a NX5010 and a MDS9509.  The 9509 is running the legacy storage systems but we are moving to FCoE on the NEXUS.  I am not getting link on the fiber between the 2 devices.  I have checked and verified the MM cable both SFP units have been swapped out.
    I keep getting the following on the MDS when I bring up the interface.
    2011 Apr 22 20:39:42 MDS9509_01 %PORT-5-IF_DOWN_INACTIVE: %$VSAN 1%$ Interface fc1/9 is down (Inactive)
    fc1/9 is down (Inactive)
        Port description is Connection to Nexus 5kSW01 [FC2/1]
        Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
        Port WWN is xxxxxxxxxxxxxxx
        Admin port mode is auto, trunk mode is on
    On the NX 5010 I have
    fc2/1 is down (Link failure or not-connected)
        Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
        Port WWN is xxxxxxxxxxxxxxxxx
        Admin port mode is auto, trunk mode is on
        snmp link state traps are enabled
        Port vsan is 1
        Receive data field Size is 2112
    I dont have anything really configured I am just tring to get a link to establish.  If someone has a sample configuration for this or a suggestion, I would certainly appreciate it.
    Cheers
    Mike

    Yes, the trunk interfaces must be assigned into active VSAN, even though they are trunk (TE) ports and might not even be trunking that VSAN.
    There is no concept of Spanning-Tree in Fibre Channel. Don't confuse Ethernet with FC, a lot of things a different. VSANs are similar to VLANs and  they allow you to segregate traffic, and VSAN trunking also has the same goal as VLAN trunking, but that's where the similarity with Ethernet ends.
    The loop prevention is achieved through FSPF (FC shortest path first) algorithm. Think of it as OSPF. Each VSAN runs its own FSPF process. Each FC switch has a unique Domain ID (value from 1 to 254) assigned by the FC Domain process in each VSAN. FSPF process is automatically on, it detects other switches and determines a best path between domain IDs based on FSPF interface costs (per VSAN). So it's actually more like IP routing than Ethernet STP. FC addresses are 3-byte FCID addresses where the first byte is the domain ID of the switch that the node (storage or HBA) is connected to. You are probably familiar with WWN's, but WWN's are not actually used in fibre channel frame headers, instead they are mapped to FCIDs.
    FC/SANOS is a fun topic, consider becoming CCIE Storage expert (http://www.iementor.com/ccie-storage-workbook-walkthrough-bundle-p-338.html)
    I'm not sure why it took 2 minutes for interface to come up, it should have been instanteneous, are you saying the actual interfaces didn't go Up for two minutes after changes were made?
    There's no VPC concept in fibre channel. There is a regular port channel that Cisco has on MDS/NX-OS FC switches. Yes, you can configure Port channel between NX-OS on N5K and SAN-OS/NX-OS on MDS9K. It must be configured between two switches and can't span multiple switches.

  • UCS - san-port-channel over vpc

    Hi,
    I'm hoping someone can help out with this,
    I have a setup with 2 Nexus 5548's connected over a vpc peer link and a keepalive, These two nexus switch's have a standard VPC connection to an upstream 6500. this is working fine,
    Then there are multiple native FC connections from the 5548's to 6248's. I know there is the option to configure FC port-channel's on the UCS 2.0 but is it possible to put fc interfaces of the nexus 5548 into a san port-channel across a vpc between the the nexus 5548's.
    so for example, can i port-channel the following across a vpc or is a san port-channel restricted to ports on the same nexus switch only.
    Fabric A  fc1/31 & fc1/32    uplinked to  -> NX5K-1  Port fc1/31 & NX5K-2 Port fc1/32 (san port-channel 10 over a VPC)
    Fabric B  fc1/31 & fc1/32    uplinked to  -> NX5K-1  Port fc1/32 & NXFK-2 Port fc1/31 (san port-channel 11 over a VPC)
    Thanks,
    Ray.

    This is not possible. Vpc is layer 2 only ethernet port channel. San port channel cannot be built accross vpc
    Sent from Cisco Technical Support iPhone App

  • What can be the max difference in cable lengths that we can have between the ISLs in a port-channel between MDS switches?

    Hello All
    What can be the max difference in cable lengths that we can have between the ISLs in a port-channel between MDS switches? Do we have any documentation?
    Thanks
    Chetan

     competitive solution instead recommends a distance variance of 30 meters or less among ISLs within a trunk. If the distance variance is greater than 30 meters, undesired and degraded performance will occur. For example, if a trunk has a distance of 100 kilometers, the competitive trunking solution allows a cable length variance of only 0.03 percent!
    ref;
    http://www.cisco.com/c/en/us/products/collateral/storage-networking/mds-9500-series-multilayer-directors/white_paper_c11-534878.html
    hth
    regards
    inayath
    **********PLZ dont forget to rate if this info is helpfull.

  • Creating san-port-channel on 6248 using CLI

    I can create the san port channel using UCS manager. But I would like to know the syntax using CLI. So far I was able to figure out the following. One thing missing was moving the port channel from the default VSAN(1) to a different VSAN i.e VSAN 10 in my case. I have looked at the CLI guide, but have not found the commands syntax. Appreciate if anyone can post the syntax
    ### Create Port Channel ###
    scope fc-uplink
    scope fabric a
    create port-channel 1
    enable
    set name port-channel-1
    set adminspeed auto
    commit-buffer
    end
    ### Add interfaces to Port Channel ###
    scope fc-uplink
    scope fabric a
    scope port-channel 1
    create member-port 1 29
    exit
    create member-port 1 30
    commit-buffer
    end

    Thanx Wdey. That's exactly what I was looking for. Here is the syntax which works for me.
    scope fc-uplink
        scope fabric a
            create port-channel 1
            enable
            set name port-channel-1
            set adminspeed auto
        commit-buffer
    end
    scope fc-uplink
        scope fabric a
            enter port-channel 1
                enable
                enter member-port 1 29
                enable
                exit
                enter member-port 1 30
                enable
                exit
                set adminspeed auto
            exit
            enter vsan VSAN10 10 10
                set fc-zoning disabled
                set fcoe-vlan 10
                set id 10
                enter member-port-channel a 1
                exit
                localize
             exit
         end
    commit-buffer

  • Port-channel between ACE4710 and switch

                   Hi all,
    I have configured port-channels on ACE and switch. Full-duplex and speed 1000Mbps are set on both sides. The configurations of port-channel on both sides is same. But there are output drops on the switch. See:
      Last clearing of "show interface" counters 00:31:24
      Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 536
    Why there are output drops on the switch? There is no half-duplex and both sides have the same speeds.
    Thank you
    Roman

    Hi Roman,
    Please paste the configuration of the ACE and Switch
    Cesar R
    ANS Team