Sap script  - Incrementing Counter

Hi all,
This is the code I have written in the main window of sap scrpt.
/: BOX FRAME 10 TW
/E MAIN
p3 &spaces(3)&&itab-carrid& &spaces(35)& &itab-connid&
= &spaces(25)&&itab-fldate&
/: PERFORM Z_V_SCRIPT IN PROGRAM Z_V_SCRIPT_SR
/: USING &COUNTER&
/: CHANGING &COUNTER&
/: ENDPERFORM
/: IF &COUNTER& EQ '1'
/: &ULINE(45)&
/: DEFINE &COUNTER& = 0
/: endif
This is the code for external subroutine z_v_script_sr.
REPORT  Z_V_SCRIPT_SR.
FORM z_v_script TABLES  IN_PAR STrUCTURE ITCSY
                      OUT_PAR STRUCTURE ITCSY.
data : cntr type i value  -1.
data : ch(3) type c.
read table in_par with key 'COUNTER'.
if sy-subrc = 0.
cntr = in_par-value.
endif.
cntr =  cntr + 1.
ch  = cntr.
read table out_par with key 'COUNTER'.
if sy-subrc = 0.
out_par-value = ch.
endif.
MODIFY OUT_PAR INDEX SY-TABIX.
write : 'vijay'.
endform.
I do not understand where I am going wrong.If I debug the subroutine the value of counter is being changed to 1 but it is not reflected when I debug my script. Please explain me where I am going wrong.
Regards,
Varun

You counter must be held in global memory, otherwise it will always be the same.  PUt the data statement at the top of your print program.  Having it defined in the routine, means that everytime the routine is fired, it will be that value. In this case -1.
data : cntr type i value -1.
ALso, comment out the USING line in the SAPscript.
/: PERFORM Z_V_SCRIPT IN PROGRAM Z_V_SCRIPT_SR
<b>/* USING &COUNTER&</b>
/: CHANGING <b>&COUNTER&</b>
/: ENDPERFORM
/: IF &COUNTER& EQ '1'
/: &ULINE(45)&
/: DEFINE &COUNTER& = 0
/: endif
Also shouldn't the counter field be defined in the print program as well.   
Is COUNTER defined in the print program?
Regards,
Rich Heilman

Similar Messages

  • Problem in sap-script, page count when trigger new page.

    Hi to all,
    Please help on my sap-script problem. When I trigger new-page the page count should continue.
    Ex: I have total of 2 pages, the second page is trigger in new-page. the page count of 2nd page should show as Page 2 of 2. but it shows on me is still Page 1 of 2.
    my command of new-page is in the zprogram. using function command_control
    thanks to all,
    I will reward points.
    Booh.

    Hi ,
    use &PAGE& of &SAPSCRIPT-formpages&
    IF Found Helpfull.
    Do Reward.
    Regards.
    Eshwar

  • Counting lines in SAP script

    Hi Gurus,
    Can someone help me count the number of lines in a sap script in a page.
    Thanks in advance!

    Hi rajbans..
    Try with this  code....
    /: DEFINE &COUNTER& = &Counter& + 1.
    /: DEFINE &SAPSCRIPT-COUNTER_9& = 0
    /: &SAPSCRIPT-COUNTER_9(+)&
    I hope this will work but am not sure.
    Thanks & Regards
    Gopal.B

  • How to print the text in points wise in sap script

    hi friends,
    how to print the text in points wise in sap script.
    ex: if suppose paragraph consists of 15 lines. then according to one sentence or one fullstop (.) it should give point 1. like that...
    1. hai how ru.
    2. what r  u doing.
    3.where r u.
    like this i want numbering.. waiting for ur replys.
    thanks,
    kiran

    declare a counter
    data : cnt type char 4.
    print :
    cnt = cnt + 1.
    &cnt& &text&
    cnt = cnt + 1. and so on.
    or.
    if the data is in an internal table
    loop at internal_table.
    cnt = cnt + 1.
    write form.
    in script -&cnt& &text&
    endloop.
    Edited by: NIKHILKUMAR POOJARI on Nov 17, 2008 11:18 AM

  • Find line no in sap script page

    In sap script there are five pages to be printed
    I want to check in each page the first line exists or not.
    as well as to identify the first line of each page.
    How to get a line number for each page in Sap script
    Please revert back asap
    Thanks

    hi ,
    there is no specific field for this you have to put a counter for that check these links
    Link for SAP Scripts (step by step procedure)
    http://smoschid.tripod.com/How_to_do_things_in_SAP/How_To_Create_A_SAPSCRIPT_Form/How_to_Create_SAPSCRIPT.html
    SAPScripts
    http://esnips.com/doc/1ff9f8e8-0a4c-42a7-8819-6e3ff9e7ab44/sapscripts.pdf
    http://esnips.com/doc/1e487f0c-8009-4ae1-9f9c-c07bd953dbfa/script-command.pdf
    http://esnips.com/doc/64d4eccb-e09b-48e1-9be9-e2818d73f074/faqss.pdf
    http://esnips.com/doc/cb7e39b4-3161-437f-bfc6-21e6a50e1b39/sscript.pdf
    http://esnips.com/doc/fced4d36-ba52-4df9-ab35-b3d194830bbf/symbols-in-scripts.pdf
    http://esnips.com/doc/b57e8989-ccf0-40d0-8992-8183be831030/sapscript-how-to-calculate-totals-and-subtotals.htm
    SAP SCRIPT FIELDS
    http://help.sap.com/saphelp_erp2005vp/helpdata/en/d1/8033ea454211d189710000e8322d00/content.htm
    scripts easy material
    http://www.allsaplinks.com/sap_script_made_easy.html
    regards,
    venkat.

  • Finding last page in SAP Script when there are  multiple layouts involved?

    Hi,
    I want to find out the last page in the SAP script. I have used &NEXTPAGE& = '0', this is finding the last page of a one layout however I do have three layouts in my script. I have also used the &SAPSCRIPT-JOBPAGES(3ZC)& and I have taken one counter and comapred as follows-
    If &SAPSCRIPT-COUNTER_1(+)&  = &SAPSCRIPT-JOBPAGES(3ZC)&
    LAST PAGE.
    endif.
    This is also not working. Please advise if there is anyway to find out the last page from print program.
    Thanks,
    Jyoti

    Hi,
    U can do like this, Set a flag in ur driver program when u reach to print the last layout then pass this flag value to Script. In script check when this FLAG = 'X' & &NEXTPAGE& = 0 then u print the required in ur last page.
    Eg:
    define a FLAG in ur driver program and make the value as 'X' when it reach the last layout.
    in script, write the condition like:
    /:  IF &FLAG& = 'X' AND &NEXTPAGE& = 0
         write text.
    /:  ENDIF.
    Hope it helps!!
    Rgds,
    Pavan

  • How to display the number of line items in sap-script report?

    Hi friends,
    I need a help regarding the SAP Script. In my script (report) I create two pages and created three windows (MAIN, HEADER, FOOTER) for each pages. Now the problem is while displaying the fewer line item which can come under the main window of the 1st page these line items are comming perfectly but for the remaining line items that comes on the second page the table headings and the boexs are not comming.
    Also it is displaying the total and the amount in text in every pages that should be display in last page.
    Here if I eleminate or comments the total and the amount in text for the first page the same is reflected in second page. Also I need to display the page-nor for each pages to displayed.
    I am requesting all the people out there kindly help me to solve this issues.
    Thanks and Regards

    There is no pre built solution for this. But we can show total pages in the report body.
    one way is Create a other column in the report with code sum(count(1))/25. that gives you total number of pages. 25 here is no of rows in each page. The code you can write in narrative "Total pages in the report are @5" and out put may be "Total Pages in the report are 30".
    If you are using pivot tables, you can try this.
    http://oraclebizint.wordpress.com/2008/01/17/oracle-bi-101332-pagination-in-pivot-tables/
    - Madan

  • Problem in Sap Script while printing

    HI,
    This report calling when I print billing document .this report getting data and call some sap script form but it prints 20 pages in place of only one page. Please
    Guide me to finding the exact problem.the code is below..
    REPORT zsd_excinv LINE-SIZE 110 LINE-COUNT 100 MESSAGE-ID vn.
    TABLES: vbco3,           "Keyfelder Vertriebsbeleg: Dokumentendruck
            tvko,            "Verkaufsorganisation
            sadr,            "Adressen
            komk,            "Communicationarea for conditions
            komp,            "Communicationarea for conditions
            komvd,           "Communicationarea for conditions
            vbdkr,           "Druck Rechnung: Kopfdaten
            vbdpr,           "Druck Rechnung: Positionsdaten
            conf_out,        "Configuration data
            vbpla,           "Druck Packliste   : allgemeine Daten
            vbplk,           "Druck Packliste   : Versandelementkopfdaten
            vbplp,           "Druck Packliste   : Versandelementinhaltsdaten
            vbpls.           "Druck Packliste   : Summendaten Verpackung
    TABLES : j_1iexchdr, j_1iexcdtl, vbrk,eikp,j_1imocust,likp,
             j_1iregset, itcpp,kna1, t001w.
    *PARAMETER : p_grp LIKE j_1iexchdr-exgrp.
    *SELECT-OPTIONS : so_num FOR j_1iexchdr-exnum.
    *PARAMETERS : p_num LIKE j_1iexchdr-exnum.
    DATA : wa_j_1iexchdr TYPE j_1iexchdr,
           it_j_1iexchdr TYPE TABLE OF j_1iexchdr.
    DATA : wa_j_1iexcdtl TYPE j_1iexcdtl,
           it_j_1iexcdtl TYPE TABLE OF j_1iexcdtl.
    DATA : wa_vbrk TYPE vbrk,
           wa_vbrp TYPE vbrp,
           wa_lips TYPE lips,
           wa_j_1iregset TYPE j_1iregset,
           wa_j_1iwrkcus TYPE j_1iwrkcus,
           wa_j_cust TYPE j_1imocust,
           it_vbrp TYPE TABLE OF vbrp.
    DATA : BEGIN OF wa_header,
             exnum TYPE j_1iexchdr-exnum ,
             exdat TYPE j_1iexchdr-exdat ,
             exccd TYPE j_1iregset-j_1iexccd,
             excrg TYPE j_1iregset-j_1iexcrg,
             excd1 TYPE j_1iregset-j_1iexcdi,
             bstnk_vf TYPE vbrk-bstnk_vf,
             zterm TYPE vbrk-zterm,
             iever TYPE eikp-iever,
             btgew TYPE likp-btgew,
             chapid TYPE j_1iexcdtl-chapid,
             traid TYPE likp-traid,
             rdoc TYPE j_1iexchdr-rdoc,
             maktx TYPE j_1iexcdtl-maktx,
             meins  TYPE likp-gewei,
          END OF wa_header.
    *DATA : BEGIN OF wa_header,
            exnum TYPE j_1iexchdr-exnum ,
            exdat TYPE j_1iexchdr-exdat ,
            exccd TYPE j_1iregset-j_1iexccd,
            excrg TYPE j_1iregset-j_1iexcrg,
            excd1 TYPE j_1iregset-j_1iexcdi,
            bstnk_vf TYPE vbrk-bstnk_vf,
            zterm TYPE vbrk-zterm,
            iever TYPE eikp-iever,
            btgew TYPE likp-btgew,
            ntgew TYPE likp-ntgew,
            chapid TYPE j_1iexcdtl-chapid,
            traid TYPE likp-traid,
            rdoc TYPE j_1iexchdr-rdoc,
            maktx TYPE j_1iexcdtl-maktx,
            meins  TYPE likp-gewei,
         END OF wa_header.
    *DATA : BEGIN OF wa_detail,
           zeile TYPE j_1iexcdtl-zeile,
           matnr TYPE j_1iexcdtl-matnr,
           maktx TYPE j_1iexcdtl-maktx,
           menge TYPE j_1iexcdtl-menge,
           rate TYPE konv-kbetr,
           amount TYPE konv-kwert,
           fob TYPE konv-kwert,
            meins  TYPE j_1iexcdtl-meins,
    *END OF wa_detail.
    *DATA : BEGIN OF wa_duties,
          zpr0 TYPE konv-kbetr,
          jadc TYPE konv-kbetr,
          st1 TYPE konv-kwert,
          jexp TYPE konv-kbetr,
          jecs TYPE konv-kbetr,
          st2 TYPE konv-kwert,
          jetc TYPE konv-kbetr,
          st3 TYPE konv-kwert,
          jsad TYPE konv-kbetr,
          st4 TYPE konv-kwert,
          st5 TYPE konv-kwert,
          vat TYPE konv-kbetr,
          st6 TYPE konv-kwert,
          zint TYPE konv-kbetr,
          jead TYPE konv-kbetr,
          zect TYPE konv-kbetr,
          zsad TYPE konv-kbetr,
          vat_per TYPE konv-kbetr,
          vat_val TYPE konv-kwert,
          total TYPE konv-kwert,
          remtime TYPE j_1iexchdr-remtime,
          exdat TYPE j_1iexchdr-exdat,
    *END OF wa_duties.
    *DATA : wa_t618t TYPE t618t.
    *DATA : in_words  TYPE spell,
          word TYPE spell-word,
          decword TYPE spell-decword,
          gv_plant_adrnr TYPE t001w-adrnr,
          lv_iever TYPE eikp-iever,
          lv_btgew TYPE likp-btgew,
          lv_ntgew TYPE likp-ntgew,
          lv_traid TYPE likp-traid,
          lv_regid TYPE j_1iregset-j_1iregid,
          gv_cust_adrnr TYPE kna1-adrnr,
          gv_ecsduty TYPE konv-kbetr,
          gv_tot_cen_amt TYPE konv-kwert,
          gv_zterm TYPE tvzbt-vtext,
          gv_tot_amt TYPE konv-kwert,
          lv_ins TYPE konv-kbetr,
          lv_fre TYPE konv-kbetr.
    *CONSTANTS : c_ecs TYPE j_1iexcdtl-ecsrate VALUE '0.368'.
    *SELECT-OPTIONS : so_num FOR j_1iexchdr-exnum.
    DATA : BEGIN OF wa_detail,
            zeile TYPE j_1iexcdtl-zeile,
            matnr TYPE j_1iexcdtl-matnr,
            maktx TYPE j_1iexcdtl-maktx,
            menge TYPE j_1iexcdtl-menge,
            rate TYPE konv-kbetr,
            amount TYPE konv-kwert,
            fob TYPE konv-kwert,
            meins  TYPE j_1iexcdtl-meins,
    END OF wa_detail.
    DATA : BEGIN OF wa_duties,
           zpr0 TYPE konv-kwert,
           jadc TYPE konv-kwert,
           st1 TYPE konv-kwert,
           jexp TYPE konv-kwert,
           jecs TYPE konv-kwert,
           st2 TYPE konv-kwert,
           jetc TYPE konv-kwert,
           st3 TYPE konv-kwert,
           jsad TYPE konv-kwert,
           st4 TYPE konv-kwert,
           st5 TYPE konv-kwert,
           vat TYPE konv-kwert,
           st6 TYPE konv-kwert,
           zint TYPE konv-kwert,
           jead TYPE konv-kwert,
           jeap TYPE konv-kwert,
           jeap_per TYPE konv-kbetr,
           zect TYPE konv-kwert,
           zect_per TYPE konv-kbetr,
           zecs TYPE konv-kwert,
           zsad TYPE konv-kwert,
           vat_per TYPE konv-kwert,
           vat_val TYPE konv-kwert,
           zlst_per TYPE konv-kwert,
           zlst_val TYPE konv-kwert,
           zcst_per TYPE konv-kwert,
           zcst_val TYPE konv-kwert,
           zeap TYPE konv-kwert,
           zeap_per TYPE konv-kbetr,
           total TYPE konv-kwert,
           remtime TYPE j_1iexchdr-remtime,
           exdat TYPE j_1iexchdr-exdat,
    END OF wa_duties.
    DATA : wa_t618t TYPE t618t.
    DATA : temp    TYPE konv-kwert VALUE 0,
           cen_amt TYPE konv-kbetr VALUE 0.
    DATA : in_words  TYPE spell,
           word TYPE spell-word,
           decword TYPE spell-decword,
           gv_plant_adrnr TYPE t001w-adrnr,
           lv_iever TYPE eikp-iever,
           lv_btgew TYPE likp-btgew,
           lv_traid TYPE likp-traid,
           lv_regid TYPE j_1iregset-j_1iregid,
           gv_cust_adrnr TYPE kna1-adrnr,
           gv_ecsduty TYPE konv-kbetr,
           gv_tot_cen_amt TYPE konv-kwert,
           gv_zterm TYPE tvzbt-vtext,
           gv_tot_amt TYPE konv-kwert,
           gv_amount TYPE konv-kwert,
           lv_ins TYPE konv-kbetr,
           lv_fre TYPE konv-kbetr.
    CONSTANTS : c_ecs TYPE j_1iexcdtl-ecsrate VALUE '0.368',
                rdocyr TYPE j_1iexchdr-docyr VALUE 2006.
    DATA : wa_t685t TYPE t685t.
    DATA : gv_zint TYPE t685t-vtext,
           gv_vat TYPE t685t-vtext,
           gv_zect TYPE t685t-vtext,
           gv_jetc TYPE t685t-vtext,
           gv_jeap TYPE t685t-vtext,
           gv_jecs TYPE t685t-vtext,
           gv_zlst TYPE t685t-vtext,
           gv_zcst TYPE t685t-vtext,
           gv_zeap TYPE t685t-vtext,
           gv_jadc TYPE t685t-vtext.
    INCLUDE rvadtabl.
    DATA: BEGIN OF lvbplk OCCURS 0.
            INCLUDE STRUCTURE vbplk.   "Packlistenkopf
    DATA: END OF lvbplk.
    DATA: BEGIN OF lvbplp OCCURS 0.
            INCLUDE STRUCTURE vbplp.   "Packlistenposition
    DATA: END OF lvbplp.
    DATA: BEGIN OF lvbpls OCCURS 0.
            INCLUDE STRUCTURE vbpls.   "Packlistenstruktur
    DATA: END OF lvbpls.
    DATA: BEGIN OF tvbdpr OCCURS 0.        "Rechnungspositionen
            INCLUDE STRUCTURE vbdpr.
    DATA: END OF tvbdpr.
    DATA: BEGIN OF tvbplp OCCURS 10.       "Packlistenposition
            INCLUDE STRUCTURE vbplp.
    DATA: END OF tvbplp.
    DATA: BEGIN OF tkomv OCCURS 50.
            INCLUDE STRUCTURE komv.        "Kommunikation
    DATA: END OF tkomv.
    DATA: BEGIN OF tkomvd OCCURS 50.
            INCLUDE STRUCTURE komvd.       "Kommunikation
    DATA: END OF tkomvd.
    DATA: BEGIN OF *tkomvd OCCURS 50.
            INCLUDE STRUCTURE komvd.
    DATA: END OF *tkomvd.
    DATA: BEGIN OF hkomvd OCCURS 50.
            INCLUDE STRUCTURE komvd.
    DATA: END OF hkomvd.
    DATA: BEGIN OF tkomcon OCCURS 50.
            INCLUDE STRUCTURE conf_out.
    DATA: END   OF tkomcon.
    DATA: retcode   LIKE sy-subrc.         "Returncode
    DATA: repeat(1) TYPE c.
    DATA: xscreen(1) TYPE c.               "Output on printer or screen
    DATA: pr_kappl(01)   TYPE c VALUE 'V'. "Application für Preisfindung
    DATA: print_mwskz.                     "Mehrwertsteuer-Kz drucken
    data for access to central address maintenance
    INCLUDE sdzavdat.
          FORM ENTRY                                                    *
          Einstieg für Nachrichtensteuerung                             *
    -->  RETURN_CODE                                                   *
    -->  US_SCREEN                                                     *
    FORM entry USING return_code us_screen.
      CLEAR retcode.
      xscreen = us_screen.
    Formular öffnen, aufbereiten und schließen
      PERFORM formular_invoice USING us_screen.
      CASE retcode.
        WHEN 0.
          return_code = 0.
        WHEN 3.
          return_code = 3.
        WHEN OTHERS.
          return_code = 1.
      ENDCASE.
    ENDFORM.                    "ENTRY
          FORM FORMULAR_INVOICE                                         *
          Formular abarbeiten                                           *
    FORM formular_invoice USING proc_screen.
    Werte aufbauen
      PERFORM get_data.
    Beleg unvollständig
      IF vbdkr-uvall NE space OR
         vbdkr-uvals NE space OR
         vbdkr-uvprs NE space.
        IF proc_screen = space.
          retcode = 3.
          IF vbdkr-uvall NE space OR vbdkr-uvals NE space.
            syst-msgno = '201'.
            syst-msgid = 'VN'.
            syst-msgty = 'I'.
            PERFORM protocol_update.
          ENDIF.
          IF vbdkr-uvprs NE space.
            syst-msgno = '200'.
            syst-msgid = 'VN'.
            syst-msgty = 'I'.
            PERFORM protocol_update.
          ENDIF.
        ELSE.
          IF vbdkr-uvall NE space OR vbdkr-uvals NE space.
            MESSAGE i201.
          ENDIF.
          IF vbdkr-uvprs NE space.
            MESSAGE i200.
          ENDIF.
        ENDIF.
      ENDIF.
      CHECK retcode = 0.
    SAP-SCRIPT STEUERUNG festlegen
      PERFORM form_open USING proc_screen vbdkr-land1.
      CHECK retcode = 0.
    Formular aufbereiten
      PERFORM sd_invoice_suppl.
      CHECK retcode = 0.
    Formular schließen
      PERFORM form_close.
      CHECK retcode = 0.
    ENDFORM.                    "FORMULAR_INVOICE
          FORM GET_DATA                                                 *
          Daten besorgen                                                *
    FORM get_data.
    PERFORM vbdkr_data.    "Rechnungskopf und -liste
    PERFORM vbpla_data.    "Packliste
    ENDFORM.                    "GET_DATA
          FORM FORM_OPEN                                                *
          Formular öffnen                                               *
    -->  US_SCREEN  Output on screen                                   *
                     ' ' = printer                                      *
                     'X' = screen                                       *
    -->  US_COUNTRY County for telecommunication and SET COUNTRY       *
    FORM form_open USING us_screen us_country.
      DATA: xdevice(8) TYPE c.
      SET LANGUAGE nast-spras.
      CLEAR itcpo.
      MOVE-CORRESPONDING nast TO itcpo.
      itcpo-tdcover   = nast-tdocover.
      itcpo-tddest    = nast-ldest.
      itcpo-tddataset = nast-dsnam.
      itcpo-tdsuffix1 = nast-dsuf1.
      itcpo-tdsuffix2 = nast-dsuf2.
      itcpo-tdimmed   = nast-dimme.
      itcpo-tddelete  = nast-delet.
      itcpo-tdcopies  = nast-anzal.
      itcpo-tdprogram = sy-repid.
      itcpo-tdteleland = us_country.
      itcpo-tdsenddate = nast-vsdat.
      itcpo-tdsendtime = nast-vsura.
      IF us_screen NE space.
        itcpo-tdpreview = 'X'.
        itcpo-tdnoprint = 'X'.
      ENDIF.
      IF sy-tcode EQ 'J1IP'.
        itcpo-tdpreview = 'X'.
      ENDIF.
      CASE nast-nacha.
        WHEN '1'.
          xdevice = 'PRINTER'.
        WHEN '2'.
          xdevice = 'TELEFAX'.
          itcpo-tdtelenum = nast-telfx.
          IF nast-tland IS INITIAL.
            itcpo-tdteleland = us_country.
          ELSE.
            itcpo-tdteleland = nast-tland.
          ENDIF.
        WHEN '3'.
          xdevice = 'TELETEX'.
          itcpo-tdtelenum = nast-teltx.
          IF nast-tland IS INITIAL.
            itcpo-tdteleland = us_country.
          ELSE.
            itcpo-tdteleland = nast-tland.
          ENDIF.
        WHEN '4'.
          xdevice = 'TELEX'.
          itcpo-tdtelenum = nast-telx1.
          IF nast-tland IS INITIAL.
            itcpo-tdteleland = us_country.
          ELSE.
            itcpo-tdteleland = nast-tland.
          ENDIF.
        WHEN OTHERS.
          xdevice = 'PRINTER'.
      ENDCASE.
      CALL FUNCTION 'OPEN_FORM'
        EXPORTING
          form           = tnapr-fonam
          language       = nast-spras
          OPTIONS        = itcpo
          archive_index  = toa_dara
          archive_params = arc_params
          device         = xdevice
          dialog         = ' '
        EXCEPTIONS
          OTHERS         = 1.
      IF sy-subrc NE 0.
        retcode = sy-subrc.
        PERFORM protocol_update.
      ENDIF.
      SET COUNTRY us_country.
    ENDFORM.                    "FORM_OPEN
          FORM FORM_CLOSE                                               *
          Formular schließen                                            *
    FORM form_close.
      CALL FUNCTION 'CLOSE_FORM'           "...Ende Formulardruck
           EXCEPTIONS OTHERS = 1.
      IF sy-subrc NE 0.
        retcode = 1.
        PERFORM protocol_update.
      ENDIF.
      SET COUNTRY space.
      SET LANGUAGE space.
    ENDFORM.                    "FORM_CLOSE
          FORM SD_INVOICE_SUPPL                                         *
          Rechnung aufbereiten                                          *
    FORM sd_invoice_suppl.
      CLEAR : wa_j_1iexchdr, wa_j_1iexcdtl, wa_lips,  wa_duties,
              gv_tot_amt.
    get data from excise header
      SELECT * FROM j_1iexchdr INTO TABLE it_j_1iexchdr
      WHERE exgrp = '31'
      AND rdoc = nast-objky
      AND trntyp = 'DLFC'
      AND lifnr = space
      AND docyr = rdocyr.
    AND exdat IN so_dat.
      SORT it_j_1iexchdr BY exdat exnum.
      READ TABLE it_j_1iexchdr INTO wa_j_1iexchdr INDEX 1.
      SELECT * FROM j_1iexcdtl INTO TABLE it_j_1iexcdtl
      FOR ALL ENTRIES IN it_j_1iexchdr
      WHERE exnum = it_j_1iexchdr-exnum
      AND trntyp = 'DLFC'
      AND docno = it_j_1iexchdr-docno.
      SORT it_j_1iexcdtl BY exdat exnum.
    LOOP AT it_j_1iexchdr INTO wa_j_1iexchdr.
    *open form
    PERFORM open_form USING  'ZSD_EXCINV' 1
                              'printer'  'X'.
      MOVE : wa_j_1iexchdr-exnum TO wa_header-exnum,
            wa_j_1iexchdr-exdat TO wa_header-exdat,
            wa_j_1iexchdr-rdoc TO wa_header-rdoc.
    get plant details
      SELECT SINGLE * FROM j_1iwrkcus INTO wa_j_1iwrkcus
      WHERE j_1iwerks = wa_j_1iexchdr-werks.
      SELECT SINGLE * FROM j_1iregset INTO wa_j_1iregset
      WHERE j_1iregid = wa_j_1iwrkcus-j_1iregid.
      SELECT adrnr INTO gv_plant_adrnr FROM t001w
      WHERE werks = wa_j_1iexchdr-werks.
      ENDSELECT.
      MOVE : wa_j_1iregset-j_1iexccd TO wa_header-exccd,
             wa_j_1iregset-j_1iexcrg TO wa_header-excrg,
             wa_j_1iregset-j_1iexcdi TO wa_header-excd1.
    get order no. from vbrk
      SELECT * INTO wa_vbrk FROM vbrk
      WHERE vbeln = wa_j_1iexchdr-rdoc.
      ENDSELECT .
      MOVE : wa_vbrk-bstnk_vf TO wa_header-bstnk_vf,
       wa_vbrk-zterm TO wa_header-zterm.
      SELECT vtext FROM tvzbt INTO gv_zterm
       WHERE zterm = wa_vbrk-zterm
       AND   spras = 'EN'.
      ENDSELECT.
    get nature of removal
      SELECT iever INTO lv_iever FROM eikp
      WHERE refnr = wa_vbrk-vbeln.
      ENDSELECT.
      SELECT SINGLE * FROM t618t INTO wa_t618t
      WHERE expvz = lv_iever
      AND   spras = 'E'.
       MOVE : lv_iever TO wa_header-iever.
    *get consignment weight.
      SELECT SINGLE * FROM vbrp INTO wa_vbrp
      WHERE vbeln = wa_vbrk-vbeln.
      READ TABLE it_j_1iexcdtl INDEX 1 INTO wa_j_1iexcdtl.
      SELECT btgew traid gewei INTO (lv_btgew, lv_traid, wa_header-meins) FROM likp
      WHERE vbeln = wa_j_1iexcdtl-rdoc1.
      ENDSELECT.
      MOVE : lv_btgew TO wa_header-btgew,
             lv_traid TO wa_header-traid.
              lv_weight to wa_header-meins.
    *get chapter id
      READ TABLE it_j_1iexcdtl INTO wa_j_1iexcdtl WITH KEY exnum = wa_j_1iexchdr-exnum .
      IF sy-subrc = 0.
        MOVE : wa_j_1iexcdtl-chapid TO wa_header-chapid,
               wa_j_1iexcdtl-maktx TO wa_header-maktx.
      ENDIF.
    *get customer details.
      SELECT adrnr FROM kna1 INTO gv_cust_adrnr
      WHERE kunnr = wa_j_1iexchdr-kunag.
      ENDSELECT.
      SELECT SINGLE * FROM j_1imocust INTO wa_j_cust
      WHERE kunnr = wa_j_1iexchdr-kunag.
    *write invoice header details
      PERFORM write_form  USING '' 'APPEND' 'BODY' 'LOCCODE' .
    *get data from excise details.
      LOOP AT it_j_1iexcdtl INTO wa_j_1iexcdtl.
        MOVE : wa_j_1iexcdtl-zeile TO wa_detail-zeile,
               wa_j_1iexcdtl-matnr TO wa_detail-matnr,
               wa_j_1iexcdtl-maktx TO wa_detail-maktx,
               wa_j_1iexcdtl-menge TO wa_detail-menge,
               wa_j_1iexcdtl-meins TO wa_detail-meins.
        SELECT  SINGLE * FROM vbrp INTO  wa_vbrp
            WHERE vbeln = wa_vbrk-vbeln
            AND   matnr = wa_j_1iexcdtl-matnr.
        SELECT kbetr kwert  FROM konv
        INTO (wa_detail-rate, wa_detail-amount)
        WHERE knumv = wa_vbrk-knumv
        AND   kposn = wa_vbrp-posnr
        AND  kschl  = 'ZPR0'.
        ENDSELECT.
        SELECT kwert  FROM konv
        INTO lv_ins
        WHERE knumv = wa_vbrk-knumv
        AND   kposn = wa_vbrp-posnr
        AND  kschl  = 'ZINS'.
        ENDSELECT.
        SELECT kwert  FROM konv
        INTO lv_fre
        WHERE knumv = wa_vbrk-knumv
        AND   kposn = wa_vbrp-posnr
        AND  kschl  = 'ZFRE'.
        ENDSELECT.
         wa_detail-fob = wa_detail-amount + lv_ins + lv_fre.
        gv_tot_amt = gv_tot_amt + wa_detail-amount.
       gv_amount  =   gv_amount + wa_detail-amount.
    write item details
        PERFORM write_form  USING 'LINE_ITEMS' 'SET' 'BODY' 'MAIN' .
      ENDLOOP.
    **get insurance .
    SELECT kwert INTO lv_ins FROM konv
    WHERE knumv = wa_vbrk-knumv
    AND  kschl = 'ZINS'.
    ENDSELECT.
    **get freight .
    SELECT kwert INTO lv_fre FROM konv
    WHERE knumv = wa_vbrk-knumv
    AND  kschl = 'ZFRE'.
    ENDSELECT.
    **get net value .
       MOVE wa_vbrk-netwr TO wa_costs-grandtot.
    **calculate netvalue(fobvalue)
       wa_costs-fobval = wa_costs-grandtot + wa_costs-insurance + wa_costs-freight.
    gv_tot_amt = gv_tot_amt + lv_ins + lv_fre.
    *get values for different condition types.
    SELECT kbetr INTO wa_duties-zpr0  FROM konv
    WHERE knumv = wa_vbrk-knumv
    AND   kposn = wa_vbrp-posnr
    AND  kschl  = 'ZPR0'.
    ENDSELECT.
      SELECT kwert  INTO wa_duties-jadc FROM konv
      WHERE knumv = wa_vbrk-knumv
       AND   kposn = wa_vbrp-posnr
      AND  kschl  = 'JADC'.
        temp = temp + wa_duties-jadc.
        CLEAR : wa_duties-jadc.
      ENDSELECT.
      MOVE  : temp TO wa_duties-jadc.
      CLEAR : temp.
       wa_duties-st1 = wa_duties-zpr0 + wa_duties-jadc.
      SELECT kwert  INTO wa_duties-jexp FROM konv
       WHERE knumv = wa_vbrk-knumv
        AND   kposn = wa_vbrp-posnr
       AND  kschl  = 'JEXP'.
        temp = temp + wa_duties-jexp.
        CLEAR : wa_duties-jexp.
      ENDSELECT.
      MOVE  : temp TO wa_duties-jexp.
      CLEAR : temp.
      SELECT kwert  INTO wa_duties-jecs FROM konv
        WHERE knumv = wa_vbrk-knumv
       AND   kposn = wa_vbrp-posnr
        AND  kschl  = 'JECS'.
        temp = temp + wa_duties-jecs.
        CLEAR : wa_duties-jecs.
      ENDSELECT.
      MOVE  : temp TO wa_duties-jecs.
      CLEAR : temp.
      wa_duties-st3 =  gv_tot_amt + wa_j_1iexchdr-exbed + wa_j_1iexchdr-ecs.
      SELECT kwert  INTO wa_duties-jetc FROM konv
            WHERE knumv = wa_vbrk-knumv
             AND   kposn = wa_vbrp-posnr
            AND  kschl  = 'JETC'.
        temp = temp + wa_duties-jetc.
        CLEAR : wa_duties-jetc.
      ENDSELECT.
      MOVE  : temp TO wa_duties-jetc.
      CLEAR : temp.
       wa_duties-st3 =  wa_duties-zpr0 + wa_duties-st2 + wa_duties-jetc.
      SELECT kwert  INTO wa_duties-jsad FROM konv
      WHERE knumv = wa_vbrk-knumv
       AND   kposn = wa_vbrp-posnr
      AND  kschl  = 'JSAD'.
        temp = temp + wa_duties-jsad.
        CLEAR : wa_duties-jsad.
      ENDSELECT.
      MOVE  : temp TO wa_duties-jsad.
      CLEAR : temp.
      SELECT kbetr kwert  INTO (wa_duties-jeap_per, wa_duties-jeap) FROM konv
      WHERE knumv = wa_vbrk-knumv
       AND   kposn = wa_vbrp-posnr
      AND  kschl  = 'JEAP'.
        temp = temp + wa_duties-jeap.
        CLEAR : wa_duties-jeap.
      ENDSELECT.
      MOVE  : temp TO wa_duties-jeap.
      CLEAR : temp.
      wa_duties-jeap_per = wa_duties-jeap_per / 10.
      SELECT kbetr kwert INTO (wa_duties-zeap_per, wa_duties-zeap) FROM konv
      WHERE knumv = wa_vbrk-knumv
       AND   kposn = wa_vbrp-posnr
      AND  kschl  = 'ZEAP'.
        temp = temp + wa_duties-zeap.
        CLEAR : wa_duties-zeap.
      ENDSELECT.
      MOVE  : temp TO wa_duties-zeap.
      CLEAR : temp.
      wa_duties-zeap_per = wa_duties-zeap_per / 10.
             (st2jetcjsad)
       wa_duties-st4 =   wa_duties-st2 + wa_duties-jetc + wa_duties-jsad.
             (zpr0+st4)
       wa_duties-st5 =   wa_duties-zpr0 + wa_duties-st4 .
       SELECT kbetr  INTO wa_duties-vat FROM konv
             WHERE knumv = wa_vbrk-knumv
             AND   kposn = wa_vbrp-posnr
             AND  kschl  = 'VAT'.
       ENDSELECT.
      SELECT kbetr kwert INTO (wa_duties-vat_per, wa_duties-vat_val) FROM konv
            WHERE knumv = wa_vbrk-knumv
           AND   kposn = wa_vbrp-posnr
            AND  kschl  = 'ZVAT'.
        temp = temp + wa_duties-vat_val.
        CLEAR : wa_duties-vat_val.
      ENDSELECT.
      MOVE  : temp TO wa_duties-vat_val.
      CLEAR : temp.
      wa_duties-vat_per = wa_duties-vat_per / 10.
      SELECT kbetr kwert INTO (wa_duties-zcst_per, wa_duties-zcst_val) FROM konv
           WHERE knumv = wa_vbrk-knumv
           AND   kposn = wa_vbrp-posnr
           AND  kschl  = 'ZCST'.
        temp = temp + wa_duties-zcst_val.
        CLEAR : wa_duties-zcst_val.
      ENDSELECT.
      MOVE  : temp TO wa_duties-zcst_val.
      CLEAR : temp.
      wa_duties-zcst_per = wa_duties-zcst_per / 10.
      SELECT kbetr kwert INTO (wa_duties-zlst_per, wa_duties-zlst_val) FROM konv
            WHERE knumv = wa_vbrk-knumv
           AND   kposn = wa_vbrp-posnr
            AND  kschl  = 'ZLST'.
        temp = temp + wa_duties-zlst_val.
        CLEAR : wa_duties-zlst_val.
      ENDSELECT.
      MOVE  : temp TO wa_duties-zlst_val.
      CLEAR : temp.
      wa_duties-zlst_per = wa_duties-zlst_per / 10.
             (st5+vat)
       wa_duties-st6 =   wa_duties-vat_val + wa_duties-st5 .
      SELECT kwert  INTO wa_duties-zint FROM konv
            WHERE knumv = wa_vbrk-knumv
             AND   kposn = wa_vbrp-posnr
            AND  kschl  = 'ZINT'.
        temp = temp + wa_duties-zint.
        CLEAR : wa_duties-zint.
      ENDSELECT.
      MOVE  : temp TO wa_duties-zint.
      CLEAR : temp.
      SELECT kwert  INTO wa_duties-jead FROM konv
               WHERE knumv = wa_vbrk-knumv
               AND   kposn = wa_vbrp-posnr
               AND  kschl  = 'JEAD'.
        temp = temp + wa_duties-jead.
        CLEAR : wa_duties-jead.
      ENDSELECT.
      MOVE  : temp TO wa_duties-jead.
      CLEAR : temp.
      SELECT kbetr kwert  INTO (wa_duties-zect_per, wa_duties-zect) FROM konv
            WHERE knumv = wa_vbrk-knumv
             AND   kposn = wa_vbrp-posnr
            AND  kschl  = 'ZECT'.
        temp = temp + wa_duties-zect.
        CLEAR : wa_duties-zect.
      ENDSELECT.
      MOVE  : temp TO wa_duties-zect.
      CLEAR : temp.
      wa_duties-zect_per = wa_duties-zect_per / 10.
      SELECT kwert  INTO wa_duties-zsad FROM konv
        WHERE knumv = wa_vbrk-knumv
         AND   kposn = wa_vbrp-posnr
        AND  kschl  = 'ZSAD'.
        temp = temp + wa_duties-zsad.
        CLEAR : wa_duties-zsad.
      ENDSELECT.
      MOVE  : temp TO wa_duties-zsad.
      CLEAR : temp.
      IF wa_vbrk-kalsm = 'ZINSCR'.
        wa_duties-total = gv_tot_amt
                       + wa_duties-jexp
                       + wa_duties-jecs
                       + wa_duties-zlst_val
                       + wa_duties-zint
                     + wa_duties-jead
                       + wa_duties-vat_val
                       + wa_duties-zcst_val.
                     + wa_duties-jecs
                     + wa_duties-zeap
                     + wa_duties-zecs
                     + wa_duties-zsad
                     + wa_duties-jadc.
      ELSEIF wa_vbrk-kalsm = 'ZINFAC'.
        wa_duties-total = gv_tot_amt
                       + wa_duties-jexp
                       + wa_duties-jecs
                       + wa_duties-zlst_val
                       + wa_duties-zint
                       + wa_duties-jeap
                       + wa_duties-vat_val
                       + wa_duties-zcst_val
                     + wa_duties-jecs
                       + wa_duties-zeap
                       + wa_duties-zect.
                     + wa_duties-zsad
                     + wa_duties-jadc.
      ENDIF.
    Get Condition descriptions.
      SELECT SINGLE * FROM t685t INTO wa_t685t
      WHERE kschl = 'ZVAT' AND spras = 'EN'.
      MOVE wa_t685t-vtext TO gv_vat.
      CLEAR wa_t685t.
      SELECT SINGLE * FROM t685t INTO wa_t685t
      WHERE kschl = 'ZVAT' AND spras = 'EN'.
      MOVE wa_t685t-vtext TO gv_vat.
      CLEAR wa_t685t.
      SELECT SINGLE * FROM t685t INTO wa_t685t
      WHERE kschl = 'ZLST' AND spras = 'EN'.
      MOVE wa_t685t-vtext TO gv_zlst.
      CLEAR wa_t685t.
      SELECT SINGLE * FROM t685t INTO wa_t685t
      WHERE kschl = 'ZCST' AND spras = 'EN'.
      MOVE wa_t685t-vtext TO gv_zcst.
      CLEAR wa_t685t.
      SELECT SINGLE * FROM t685t INTO wa_t685t
      WHERE kschl = 'ZECT' AND spras = 'EN'.
      MOVE wa_t685t-vtext TO gv_zect.
      CLEAR wa_t685t.
      SELECT SINGLE * FROM t685t INTO wa_t685t
      WHERE kschl = 'ZEAP' AND spras = 'EN'.
      MOVE wa_t685t-vtext TO gv_zeap.
      CLEAR wa_t685t.
      SELECT SINGLE * FROM t685t INTO wa_t685t
      WHERE kschl = 'JETC' AND spras = 'EN'.
      MOVE wa_t685t-vtext TO gv_jetc.
      CLEAR wa_t685t.
      SELECT SINGLE * FROM t685t INTO wa_t685t
      WHERE kschl = 'JEAP' AND spras = 'EN'.
      MOVE wa_t685t-vtext TO gv_jeap.
      CLEAR wa_t685t.
      SELECT SINGLE * FROM t685t INTO wa_t685t
      WHERE kschl = 'JECS' AND spras = 'EN'.
      MOVE wa_t685t-vtext TO gv_jecs.
      CLEAR wa_t685t.
      SELECT SINGLE * FROM t685t INTO wa_t685t
      WHERE kschl = 'JADC' AND spras = 'EN'.
      MOVE wa_t685t-vtext TO gv_jadc.
      CLEAR wa_t685t.
       gv_ecsduty = wa_j_1iexchdr-exbed * ( c_ecs / 100 ).
      cen_amt = wa_duties-jexp + wa_duties-jeap.
      gv_tot_cen_amt = cen_amt + wa_duties-jecs.
      MOVE wa_j_1iexchdr-remtime TO wa_duties-remtime.
      MOVE wa_j_1iexchdr-exdat TO wa_duties-exdat.
    Convert amount to words.
      CALL FUNCTION 'SPELL_AMOUNT'
        EXPORTING
          amount    = wa_duties-total
          currency  = 'INR '
          filler    = space
          language  = sy-langu
        IMPORTING
          in_words  = in_words
        EXCEPTIONS
          not_found = 1
          too_large = 2
          OTHERS    = 3.
      IF sy-subrc <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
      ENDIF.
      MOVE : in_words-word TO word,
           in_words-decword TO decword.
    write  duty details
      IF wa_vbrk-kalsm = 'ZINSCR'.
        PERFORM write_form USING 'ZINSCR' 'APPEND' 'BODY' 'GRANDTOT' .
      ELSEIF  wa_vbrk-kalsm = 'ZINFAC'.
        PERFORM write_form USING 'ZINFAC' 'APPEND' 'BODY' 'GRANDTOT' .
      ENDIF.
    *close form
       PERFORM close_form.
    ENDLOOP.
    ENDFORM.                    "SD_INVOICE_SUPPL
          FORM FORM_TITLE_PRINT                                         *
          Formulartitel entsprenchend des Feldes VBTYP drucken          *
    FORM form_title_print.
      CASE vbdkr-vbtyp.
        WHEN 'M'.
          CALL FUNCTION 'WRITE_FORM'
            EXPORTING
             element = 'TITLE_M'
              window  = 'HEADER'
            EXCEPTIONS
              element = 1
              window  = 2.
          IF sy-subrc NE 0.
            PERFORM protocol_update.
          ENDIF.
        WHEN 'N'.
          CALL FUNCTION 'WRITE_FORM'
            EXPORTING
              element = 'TITLE_N'
              window  = 'TITLE'
            EXCEPTIONS
              element = 1
              window  = 2.
          IF sy-subrc NE 0.
            PERFORM protocol_update.
          ENDIF.
        WHEN 'O'.
          CALL FUNCTION 'WRITE_FORM'
            EXPORTING
              element = 'TITLE_O'
              window  = 'TITLE'
            EXCEPTIONS
              element = 1
              window  = 2.
          IF sy-subrc NE 0.
            PERFORM protocol_update.
          ENDIF.
        WHEN 'P'.
          CALL FUNCTION 'WRITE_FORM'
            EXPORTING
              element = 'TITLE_P'
              window  = 'TITLE'
            EXCEPTIONS
              element = 1
              window  = 2.
          IF sy-subrc NE 0.
            PERFORM protocol_update.
          ENDIF.
        WHEN 'S'.
          CALL FUNCTION 'WRITE_FORM'
            EXPORTING
              element = 'TITLE_S'
              window  = 'TITLE'
            EXCEPTIONS
              element = 1
              window  = 2.
          IF sy-subrc NE 0.
            PERFORM protocol_update.
          ENDIF.
        WHEN 'U'.
          CALL FUNCTION 'WRITE_FORM'
            EXPORTING
              element = 'TITLE_U'
              window  = 'TITLE'
            EXCEPTIONS
              element = 1
              window  = 2.
          IF sy-subrc NE 0.
            PERFORM protocol_update.
          ENDIF.
        WHEN OTHERS.
          CALL FUNCTION 'WRITE_FORM'
            EXPORTING
              element = 'TITLE_M'
              window  = 'TITLE'
            EXCEPTIONS
              element = 1
              window  = 2.
          IF sy-subrc NE 0.
            PERFORM protocol_update.
          ENDIF.
      ENDCASE.
      IF repeat NE space.
        CALL FUNCTION 'WRITE_FORM'
          EXPORTING
            element = 'REPEAT'
            window  = 'REPEAT'
          EXCEPTIONS
            element = 1
            window  = 2.
        IF sy-subrc NE 0.
          PERFORM protocol_update.
        ENDIF.
      ENDIF.
    ENDFORM.                    "FORM_TITLE_PRINT
          FORM REFERENCE_NUMBER                                         *
          Referenznummer ausgeben                                       *
    FORM reference_number.
      CHECK vbdkr-vbtyp CA 'MUN'.
      CALL FUNCTION 'WRITE_FORM'
        EXPORTING
          window = 'INVOICE'
        EXCEPTIONS
          window = 2.
      IF sy-subrc NE 0.
        PERFORM protocol_update.
      ENDIF.
    ENDFORM.                    "REFERENCE_NUMBER
          FORM HEADER_TEXT_PRINT                                        *
          Kopftexte ausgeben                                            *
    FORM header_text_print.
      CALL FUNCTION 'WRITE_FORM'
        EXPORTING
          element = 'HEADER_TEXT'
        EXCEPTIONS
          element = 1
          window  = 2.
      IF sy-subrc NE 0.
        PERFORM protocol_update.
      ENDIF.
    ENDFORM.                    "HEADER_TEXT_PRINT
          FORM ITEM_PRINT                                               *
          Rechnungsposition ausgeben                                    *
    FORM item_print.
    Kopieren LVBPLP für direkt Zugriff
      LOOP AT lvbplp.
        MOVE-CORRESPONDING lvbplp TO tvbplp.
        APPEND tvbplp.
      ENDLOOP.
      LOOP AT tvbdpr.
        vbdpr = tvbdpr.
        IF tvbdpr-charg IS INITIAL.
          PERFORM get_item_prices.
          PERFORM get_item_characteristics.
          CALL FUNCTION 'CONTROL_FORM'
            EXPORTING
              command = 'PROTECT'.
          CALL FUNCTION 'WRITE_FORM'
            EXPORTING
              element = 'ITEM_LINE'.
          PERFORM item_price_print.
          PERFORM item_characteristics_print.
          CALL FUNCTION 'CONTROL_FORM'
            EXPORTING
              command = 'ENDPROTECT'.
          PERFORM different_consignee.
          PERFORM different_order_no.
          PERFORM different_delivery_no.
          PERFORM different_extern_no.
          PERFORM different_purchase_order_no.
          PERFORM item_packing_print.
        ELSE.
          IF NOT tvbdpr-fkimg IS INITIAL.
            PERFORM get_item_prices.
            PERFORM item_price_print.
          ENDIF.
        ENDIF.
      ENDLOOP.
    ENDFORM.                    "ITEM_PRINT
          FORM ITEM_PACKING_PRINT                                       *
          Verpackung zu einer Position ausgeben                         *
    FORM item_packing_print.
      DATA: count LIKE sy-index.
      DATA: BEGIN OF hvbplp OCCURS 0,
              stufe     TYPE i.
              INCLUDE STRUCTURE vbplp.
      DATA: END OF hvbplp.
      DATA: vs_element LIKE vbplp-venum.
      CLEAR   hvbplp.
      REFRESH hvbplp.
    Aufbau Versandelementstruktur für Ausgabe
      LOOP AT tvbplp WHERE vbeln = vbdkr-vbeln AND posnr = tvbdpr-posnr.
        hvbplp-stufe = 1.
        MOVE-CORRESPONDING tvbplp  TO hvbplp.
        APPEND hvbplp.
        vs_element = tvbplp-venum.
        IF vs_element EQ ' '. EXIT. ENDIF.         "unverpackt
        CLEAR lvbplk.
        WHILE lvbplk-kzobe NE 'X'.       "nicht oberstes VS-Ele
          suchen übergeordnetes Versandelement
          LOOP AT lvbplp WHERE unvel = vs_element.
            hvbplp-stufe = hvbplp-stufe + 1.
            MOVE-CORRESPONDING lvbplp  TO hvbplp.
            APPEND hvbplp.
            EXIT.
          ENDLOOP.
          vs_element = lvbplp-venum.
          lesen übergeordnetes Versandelement
          READ TABLE lvbplk WITH KEY vs_element.
          IF sy-subrc NE 0.
            EXIT.
          ENDIF.
        ENDWHILE.
      ENDLOOP.
      SORT hvbplp BY stufe venum.
      CLEAR vbplp.
      LOOP AT hvbplp.
        lesen Versandelement
        CLEAR vbplk.
        CLEAR vbpls.
        IF hvbplp-venum EQ ' '.

    Hi,
    SAPScript addresses are formated by postal standards...irrespective of the data populated....
    In line
    /: ADDRESS PARAGRAPH LZ
    change to
    /: ADDRESS DELIVERY PARAGRAPH LZ
    that should bring the street into the address
    Regards
    Stu

  • Issue in New Page Display in a SAP Script

    Hi All
             I have applied a line count logic in my SAP script, such that if lines are more than 32, Sub Total is displayed on this page(Sub Total needs 4 lines to display) and from next page,another heading starts. (Total around 39 lines can be displayed  in one page)
    Sub Total Text contains 2 lines of text, and 2 blank lines after it (Total 4 lines)
    Now, if number of lines is around 36, Sub Total, doesnt fully display in this page and the 2 blank lines gets passed to the next page. And I am also firing a new page from my code. As a result, the 2nd page comes fully blank and the data is now being displayed at the 3rd page. How can I prevent the 2nd page from coming blank ??
    I am using Function Module 'CONTROL_FORM' (or WRITE_FORM) to fire a new page.
    I do not want to apply a line count logic for this as this wont be fool proof !!
    I hope I have made the issue clear. Kindly help !!
    Thanks
    KP

    Hi,
    otherwise u can do one thing: U call the PERFORM in the SCRIPT FORM passing the &PAGE&(Contains the current Page No) value to it. take a loal variable and pass the PAGE value to the local variable and check for every line whether both &PAGE& & local varaiable are same, if not then set the FLAG value to 'X' (it means the new page has triggered).
    Eg:
    In Script:
    /:  lv_tabix = lv_tabix + 1.
    /: PERFORM new_page_flag IN PROGRAM ZXXXXX
    /: USING &PAGE&
    /: USING &lv_tabix&
    /: CHANGING &FLAG&
    In ZXXXXX Program:
    FORM new_page_flag USING int_tab STRUCTURE itcsy
                                CHANING out_tab STRUCTURE itcsy.
    data : lv_page TYPE i,
             lv1_tabix TYPE i.
    READ TABLE int_tab WITH KEY name = 'LV_TABIX'.
    IF sy-subrc EQ '0'.
      lv1_tabix = int_tab-value.
      clear : int_tab.
    ENDIF.      
    IF lv1_tabix EQ '1'.
      lv_page = '1'.
    ENDIF.
    READ TABLE int_tab WITH KEY name = 'PAGE'.
    IF lv1_tabix GT '1'.
      IF lv_page NE  int_tab-value.
        READ TABLE out_tab WITH KEY name = 'FLAG'.
        IF sy-subrc EQ 0.
           out_tab-value = 'X'.
           MODIFY out_tab.
           clear : out_tab.
        ENDIF.
      ENDIF.
    ENDIF.
    IF sy-subrc EQ '0'.
      lv_page = int_tab-value.
    ENDIF.                          
    Hope it helps!!
    Rgds,
    Pavan

  • How to use print control in Sap script

    I would like to use print control in Sap script.Actualy my problem I have security font Troy ECF. Using this font I would like to print amount field in Check printing.
    we count download this font with sap .we talked to customer care they told we should hard code in sapscript. pls can any1 help on this how to do and how to use print control for this fonts.

    call this funcation. crate_text.
    CALL FUNCTION 'CREATE_TEXT'
             EXPORTING
               FID               =
               FLANGUAGE         =
               FNAME             =
               FOBJECT           =
             SAVE_DIRECT       = 'X'
             FFORMAT           = '*'
             TABLES
               FLINES            =
           EXCEPTIONS
             NO_INIT           = 1
             NO_SAVE           = 2
             OTHERS            = 3
           IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
           ENDIF.

  • Sap Script - putting dynamic height value in box command

    Hello All,
    In SAP scirpt I have to display a table which might have variable number of line items. So in box command I cannot mention the height statically.
    Is it possible to specify that dynamically like by using a variable and incrementing it every time the element is called from the loop?
    Thanks
    Indrajit

    no in SAP-SCRIPT this aint possible. But you could do this in an external perform, and have your incremented value back, tho since a external perform is beeing called from the form, the box statement might already have been interpreted.
    this again would mean that this way wouldnt work as well then.

  • Sap script & Check no.

    Hi ALL
         I am working on Check print using f110_prenum_chck.
    The problam is  that if the  invoice line item overflow to next page then the first page should be considered as first check and it should not get voided. the remaining pages, check should not be printed or can be void..........
    Also check number should take just one insted of 10 if the invoice line items contains up to 10 pages
    Can any one help me.
    thanks,
    Lakshmi.

    You should re-consider this as SAP offers here the good solution - minimum development with standard output.
    The major problem here is that you never know if you will need 1 or n pages.
    But if you want to solve your case I would test two directions:
    1. Find the VOID part in the print program. I would assume it is a check if the page moves to the next it voids the current page. If that is found you need to remove the counter counting up in the same time. In SAP-SCRIPT you need now to direct your NEXT page always to a different TRAY (this solution requires printer with more than one 1 tray). Set the print logic on the printer up the way that this page will be printed on a different tray.
    2. If above solution does not work and is not liked take only beginning with the VOID part and move it for all further pages and change the check counter usage.
    Can you say why you would wish to do that?
    In our case we were able to convince customers that the development and support of special solutions is a way more expensive than the usage of a view checks.

  • Enquiry in SAP SCRIPT

    Hi,
    I want to increment the vertical line dynamically according to the line items in SAP SCRIPT.
    How will I do it??
    Pooja

    hi..,
    each time u print the record in sap script at the end write &vline&.. give a tab postion for all these vertical lines and use the tab correctly....then onli u will get a straight and complete vertical line...
    plz, do remember to close the thread when ur problem is solved !!
    reward if it helps u..
    sai ramesh

  • Subroutine call from SAP Script

    Hi,
    I need to calculate required/outstanding qty. hence am passing existing values of reservation#/item# and issued qty.
    both req/out qty are returned blank by the code. please help.
    Following is my code segment for a external routine call from SAP Script.
    /:   PERFORM P_GET_QTY IN PROGRAM ZTEST
    /:   USING &MSEG-RSNUM&                     
    /:   USING &MSEG-RSPOS&                     
    /:   CHANGING &REQ_QTY&                     
    /:   CHANGING &MSEG-MENGE&                  
    /:   CHANGING &OUT_QTY&                     
    /:   ENDPERFORM
    REPORT ztest .
    TABLES resb.
    DATA: wa_resb TYPE resb,
          req_qty TYPE resb-bdmng,
          isd_qty TYPE mseg-menge,
          out_qty TYPE resb-bdmng.
    FORM p_get_qty TABLES input  STRUCTURE itcsy
                          output STRUCTURE itcsy.
      DATA: avlbl TYPE resb-bdmng.
      READ TABLE input WITH KEY 'MSEG-RSNUM'.
      CHECK sy-subrc = 0.
      wa_resb-rsnum = input-value.
      READ TABLE input WITH KEY 'MSEG-RSPOS'.
      CHECK sy-subrc = 0.
      wa_resb-rspos = input-value.
      READ TABLE input WITH KEY 'REQ_QTY'.
      CHECK sy-subrc = 0.
      req_qty = input-value.
      READ TABLE input WITH KEY 'MSEG-MENGE'.
      CHECK sy-subrc = 0.
      isd_qty = input-value.
      SELECT SINGLE * INTO wa_resb
                      FROM resb
                      WHERE rsnum = wa_resb-rsnum
                      AND   rspos = wa_resb-rspos.
      CHECK sy-subrc = 0.
      avlbl   = wa_resb-bdmng - wa_resb-enmng.
      req_qty = avlbl - out_qty.
      out_qty = req_qty - isd_qty.
      output-name = 'REQ_QTY'.
      output-value = req_qty.
    MODIFY output TRANSPORTING name value WHERE name = 'REQ_QTY'.
      APPEND output.
      output-name = 'OUT_QTY'.
      output-value = out_qty.
    MODIFY output TRANSPORTING name value WHERE name = 'OUT_QTY'.
      APPEND output.
    ENDFORM.
    Thanks,
    Ram.

    Hi Ram,
    I think you have to use MODIFY instead of append for the OUTPUT table.
    MOdify the table with KEY. This should resolve the problem.
    Ram, you can check this code and see how the MODIFY is to be used.
    REPORT YLSD999A.
    DATA  W_LENGTH TYPE I.
    *   GENERAL PURPOSE SUBROUTINES FOR CALLING FROM SAPSCRIPTS
    FORM DISPLAY_POUND TABLES IN_TAB STRUCTURE ITCSY
                              OUT_TAB STRUCTURE ITCSY.
      DATA: COUNT TYPE P VALUE 16.
      DATA: W_VALUE(17) TYPE C.        "defined as 7 chars to remove pence
      DATA: W_CHAR TYPE C.
      DATA: W_DUMMY TYPE C.
      DATA: W_CURR(3) TYPE C.
    *    Get first  parameter in input table.
      READ TABLE IN_TAB INDEX 1.
      WRITE IN_TAB-VALUE TO W_VALUE .
    * get second parameter in input table
      READ TABLE IN_TAB INDEX 2.
      MOVE IN_TAB-VALUE TO W_CURR.
      IF W_CURR = 'GBP'.
        W_CURR = '£'.
      ENDIF.
      W_LENGTH = STRLEN( W_CURR ).
    *    look for first space starting at right.
      WHILE COUNT > -1.
        W_CHAR = W_VALUE+COUNT(1).
    *  W_CHAR = IN_TAB-VALUE+COUNT(1).
        IF W_CHAR = ' '.
          COUNT = COUNT - W_LENGTH + 1.
          W_VALUE+COUNT(W_LENGTH) = W_CURR.
          COUNT = -1.
        ELSE.
    *     W_VALUE+COUNT(1) = W_CHAR.
          COUNT = COUNT - 1.
        ENDIF.
      ENDWHILE.
    * read only parameter in output table
      READ TABLE OUT_TAB INDEX 1.
      OUT_TAB-VALUE = W_VALUE.
      MODIFY OUT_TAB INDEX SY-TABIX.
    ENDFORM.
    Cheers
    VJ

  • EXPERTS PLZ HELP ME IN SAP SCRIPT URGENT

    Hi experts
    plz help me
    i m very new in sap scripts
    i have a script WESCHEINVERS1 and the driver prog is SAPM07DR
    i ill have to copy this script and have to add two more feild in the text element W1LGMAT
    fields are :
    CAWNT-ATWTB
    EKPO-REVLV
    now wat i think i cannot make changes to standard driver prog so it wud be better to call a subroutine 4 it
    so plz guide me how i ill have to fetch data nd pass to the script
    plz write the code if possible 4 u
    FYI:
    MSEG : Document Segment Material
    MANDT     Client
    MBLNR     Number of material Document
    MJAHR     Material Document Year
    ZEILE     Item in Material Document
    MATNR     Material Number
    LIFNR     Account number or vendor
    EBELN     Purchase order number
    EBELP     Item number of PO
    EKPO : Purchasing document item
    MANDT     Client
    EBELN     Purchase order number
    EBELP     Item number of PO
    MATNR     Material Number
    REVLV     Revision Level
    LFA1 : Vendor Master (General section)
    MANDT     Client     
    LIFNR     Account number of vendor or creditor     MSEG-LIFNR
    SPRAS     Language key     
    AUSP : Characteristic Values
    MANDT     Client     
    OBJEK     Key of object to be classified     MSEG-MATNR
    ATINN     Internal characteristic     ZO-QUALITY-LEVEL
    ATZHL     Internal counter     
    ATWRT     Characteristic Value     
    CAWNT : Value texts
    MANDT     Client     
    ATINN     Internal characteristic     ZO-QUALITY-LEVEL
    ATZHL     Internal counter     AUSP-ATZHL
    SPRAS     Language Key      LFA1-SPRAS
    ATWTB     Characteristic Value Description     
    thanks in advance

    Refer the links to know about calling subroutines ins cript -
    subroutine in script
    How to call a subroutine in a script ?
    EXTERNAL SUBROUTINE IN SAP SCRIPT
    Regards,
    Amit
    Reward all helpful replies.

Maybe you are looking for

  • I feel scammed and cheated by your deskjet 1000. picked it up, looked at the specs on the box...

    and there was no disclaimer that i would need anything aside from my computer to get this up and running.  once i install everything, i find out i need a special usb cord, which i might have somewhere but i cant find it, and so now i am going to have

  • 23" HD Display (ADC/2004 model); Display Software Won't Load

    I have a Quicksilver 733Mhz w/OSX Tiger and just bought a used 23" HD Cinema Display (ADC) which works great. Yet as the menu bar appears very small I thought the Display S/W (v2.2.2) will not load--during license agreement/select destination load, t

  • Weird problem and I need your help!

    Hello, I'll keep this short and hopefully someone will be able to give me a simple answer to this problem - it's been driving me nuts for days! Here's the situation, as concise as I can be: - import clips from my video camera to iMovie, no problem -

  • Invisible text in acrobat forms

    For a number of years and a number of different versions of Acrobat we have noted that a form filled out across platforms may not show the filled in text unless it is highlighted.  I've searched Google and the Adobe site and found a number of discuss

  • JDBC connection to AS/400 in SQL0204 error

    Hi, I'm trying to execute a statement on AS/400 from a JDBC receiver adapter. The statement looks like this: <ns0:MT_PriceCall_JDBC_Article_Request xmlns:ns0="urn:delixl:poc">   <Statement>     <KT0100S action="EXECUTE">       <CUSTOMER type="VARCHAR