SCCM 2012 R2 and Windows 8.1

Hi,
I have installed SCCM 2012 R2. SCCM client deployed on 10 PCs and I can explore Hardware resources on all PCs except 1 PC which is 8.1
so my question now does SCCM 2012 R2 supports 8.1?
Thanks,
Kareem Behery

Hi,
Yes, ConfigMgr 2012 R2 supports Windows 8.1. Check the Windows 8.1 computer to make sure that the SCCM client is operational and sends in Inventory to the Site server. Inventpryagent.log file on the computer is a good place to start.
Regards,
Jörgen
-- My System Center blog ccmexec.com -- Twitter
@ccmexec

Similar Messages

  • Wifi profiles SCCM 2012 R2 and Windows Intune

    Hi All,
    A quick question regarding SCCM 2012 R2 and the new Wifi Profiles feature...
    Can anyone confirm if you need windows Intune combined with SCCM 2012 R2 to be able to deploy WIFI profiles to users devices i.e Windows 8.1, IOS and Android platforms?  Microsoft documentation is not clear on this subject.
    Any help would be much appreciated.
    Regards PowerShell90

    It not as straight forward as one would hope. I am running the latest version of SCCM 2012 R2 CU2 connected to my Windows Intune subscription. There are a lot of hickups. One is that the direct of management needs to be all or nothing. In other words you
    either need to use Windows Intune solely to manage your devices or SCCM 2012 R2 (via connector). If the later then you must do everything from in SCCM 2012 R2. You cannot hybrid manage your devices as this will screw things up.
    Android for some reason is left out on a lot of features. I would think that MS Devs would work hard on the market share that being Android, not iOS. Any way, accord to some official MS articles Android is supported, but others claim that not all features
    are, these being the important ones like Email and Wi-Fi Profiles. They simply do not work.
    I think MS is heading in the right direction but there is a lot of work that needs to be done before this is a competitive product. I could care less if connects to my SCCM 2012 R2 server or not. Here are few things that I sent o a MS Support Rep today that
    need to be address.
    1. Better response time when updating devices after enrollment (e.g. Name change).
    2. The ability to locked down uninstalling Windows Intune from device.<o:p></o:p>
    3. The ability to locked down certain features in the Windows Intune app on device (e.g. User can reset device with Windows Intune app, rename, etc...).<o:p></o:p>
    4. Ability to rename device in either Windows Intune Admin Portal and/or SCCM 2-12 R2.<o:p></o:p>

  • SCCM 2012 R2 and windows 7 folder redirection

    Hello gurus
    I want to ask a quick question. Does anyone know if I can do folder redirection, offline folders, roaming profiles and network drive on Windows 7 using SCCM 2012 R2?
    Thanks in advance. 
    Regards,

    The setting does not apply to Windows 7. I tested and DCMagent just thought it is Non-applicable.
    Juke Chou
    TechNet Community Support

  • SCCM 2012, Intune and Windows OS Support

    I am just trying to confirm what I believe I am reading about Microsoft OS Support for Windows Intune when integrated with SCCM 2012 R2...
    What I believe to be the case:
    Windows RT, Windows RT 8.1, Windows 8.1 all have the ability to enroll via OMA-DM, thus can be managed by SCCM.
    Down-level OS's such as XP SP3, Vista, and Windows 7 require the Intune Client to be installed, thus can only be managed by a standalone Intune subscription?
    Can anyone confirm this?
    Thanks!

    More or less correct.
    Generally, even for Win 8.1 and WinRT, IBCM or DirectAccess are a better choice than OMA-DM as it can only enable management of a limited subset of features. Two important ones cannot be: software updates and endpoint protection.
    As you've seen (based on your other thread), you can still use the Intune subscription that is connected to your ConfigMgr site to manage devices with the Intune client installed. Effectively, there are two halves of the Intune subscription, the full client
    management half and MDM half which can be controlled by Intune or ConfigMgr. Just because the MDM half is controlled by ConfigMgr does not technically preclude you from still utilizing the full client management half. That's not at all saying you should do
    this though, but you certainly could.
    Jason | http://blog.configmgrftw.com

  • Windows 8.1 mobile device management using integrated environment of SCCM 2012 R2 and Windows intune

    Can we avoid the dependency on the Symantec certificate  for enabling windows phone enrollment under Administration->Cloud services -> Windows InTune subscriptions - Windows Phones. My environment will have only windows 8.1 phones.
    Regards
    Leela

    See http://status.manage.microsoft.com/StatusPage/ServiceDashboard. 
    Engineers are investigating a service issue impacting access to portal via mobile devices.
    (Started on 12/30/2014 8:00:00 AM UTC)
    1/8/2015 11:42:49 PM (UTC)
    Current Status: Engineers are continuing to troubleshoot potential issues related to Active Directory Federation Services (ADFS). Engineers have gathered additional traces and logging data for deeper analysis. User Experience: Affected users with Windows Phone,
    iOS, or Android devices are unable to access their company portal and receive repeated prompts to enter credentials. If incorrect credentials are entered, users will receive an error stating that they have entered a bad password. Customer Impact: Engineers
    have received reports that some customers are experiencing this issue. A subset of users are affected by this event. Other users remain unaffected. Incident Start Time: Tuesday, December 30, 2014, at 8:00 AM UTC Next Update by: Tuesday, January 13, 2015, at
    12:00 AM UTC
    Torsten Meringer | http://www.mssccmfaq.de

  • Microsoft Intune and SCCM 2012 R2 Integration - Windows 7 clients.

    Hi All,
    This is our scenario I am trying to find out more about Intune integration with SCCM 2012 R2 and what solution is best for us.
    We have a SCCM 2012 R2 instance up and running which services/monitors machines on our internal network. All of these machines are Windows 7 OS. We have laptops that travel frequently and need for these to report back to our SCCM server whilst connected
    via internet connections. Also we have multiple "off domain" machines (ie workgroup machines) which we also need to report back to the same SCCM server.
    I have read a lot about Intune integration with SCCM but it appears to be targetted at MDM not around PC management.
    What would be the best way for us to move forward?
    Thanks in advance.

    Just see my reply in the ConfigMgr forums. 
    Torsten Meringer | http://www.mssccmfaq.de

  • Deploy Java Updates using SCCM 2012 SP1 and SCUP 2011

    What is the best way to deploy Java updates using sccm 2012 SP1 and SCUP 2011?

    I didn´t find Kent´s blog useful when talking about Java. I can deploy Adobe products fine, but I have to import Java manually because not having Shavlik certificate. So with that said, I have the fallowing problem;
    I have full offline installer unpacked, .msi file and Data1.cab. When I´m importing these binaries to SCUP, I only can point to .msi. Doing that, installation fails in client side fails because of lack of data1.cab fine, which is the main file.
    Should I use some other downloaded files of Java? I couldn´t find any Java-update-file only type of files to download.

  • Just FYI, Windows Server 2012 R2 and Windows Server 2012 BranchCache Deployment Guide in Word format in the TechNet Gallery

    The Windows Server 2012 R2 and Windows Server 2012 BranchCache Deployment Guide is now available for download in Word format in the TechNet Gallery at
    http://bit.ly/1pYZT3F
    Thanks -
    James McIllece

    hello again,
    meanwhile I was lucky to find this article about Idenity Mapping in TechNet in the Storage Team Blog:
    http://blogs.technet.com/b/filecab/archive/2012/10/09/nfs-identity-mapping-in-windows-server-2012.aspx
    Likely to be overseen at the end of one paragraph it says:
    "Client for NFS does not support NFS V4.1 in Windows 8 or Windows Server 2012"
    Question : Is this an official statement and is it still valid with most recent
    Windows Server 2012 R2 that NFS client does NOT support NFSv4.x  ??
    thanks - Rainer

  • Cannot publish Flash Updates Verification of file signature failed for file SCUP 2011, SCCM 2012 R2 and WSUS all on same Windows Server 2012 machine

    I am attempting to distribute Adobe Flash updates using SCUP 2011, SCCM 2012 R2, WSUS ver4 and Windows Server 2012.  Everything installs without error.  I have acquired a certificate for SCUP signing from the internal Enterprise CA.  I have
    verified the signing certificate has a 1024 bit key.  I have imported the certificate into the server's Trusted Publishers and Trusted Root CA stores for the computer.  When I attempt to publish a Flash update with Full content I receive the following
    error:
    2015-02-13 23:00:48.724 UTC Error Scup2011.21 Publisher.PublishPackage PublishPackage(): Operation Failed with Error: Verification of file signature failed for file:
    \\SCCM\UpdateServicesPackages\a2aa8ca4-3b96-4ad2-a508-67a6acbd78a4\3f82680a-9028-4048-ba53-85a4b4acfa12_1.cab
    I have redone the certificates three times with no luck.  I can import metadata, but any attempt to download content results in the verification error.
    TIA

    Hi Joyce,
    This is embarrassing, I used that very post as my guide when deploying my certificate templates, but failed to change the bit length to 2048.  Thank you for being my second set of eyes.
    I changed my certificate key bit length to 2048, deleted the old cert from all certificate stores, acquired the a new signing cert, verified the key length was 2048, exported the new cert to pfx and cer files, imported into my Trusted publishers
    and Trusted Root Authorities stores, reconfigured SCUP to use the new pfx file, rebooted the server and attempted to re-publish the updates with the following results:
    2015-02-16 13:35:44.006 UTC Error Scup2011.4 Publisher.PublishPackage PublishPackage(): Operation Failed with Error: Verification of file signature failed for file:
    \\SCCM\UpdateServicesPackages\a2aa8ca4-3b96-4ad2-a508-67a6acbd78a4\3f82680a-9028-4048-ba53-85a4b4acfa12_1.cab.
    Is there a chance this content was already created and signed with the old cert, so installing the new cert has no effect?  In ConfigMgr software updates I see 4 Flash updates, all marked Metadata Only (because they were originally published as "Automatic." 
    No Flash updates in the ConfigMgr console are marked as downloaded.  I can't find any documentation on how the process of using SCUP for downloading content for an update marked Metadata Only actually works. 
    Comments and suggestions welcome.

  • Windows 8.1 Update (with WinPE 5.1) ADK + SCCM 2012 R2 and WinXP

    Hello,
    I see new ADK version (8.1 Update) is released
    http://www.microsoft.com/en-US/download/confirmation.aspx?id=39982
    It contains WinPE 5.1 and new USMT (which version?), does it support migration from WinXP to Win7?
    Previously I used USMT5 (instead of 6.3) and modified WinPE 5.0 with bootsect.exe from WinPE 4.0 (from ADK 8.0) on SCCM 2012 R2 CU3.
    And can I use ADK 8.1 Update with SCCM 2012 R2?

    He does answer your question about the USMT version.
    The rest still applies in terms of XP support. See below.
    http://blogs.technet.com/b/mniehaus/archive/2014/01/09/migrating-from-windows-xp-to-windows-8-1-using-mdt-2013.aspx
    Yes, ConfigMgr 2012 R2 is supported.
    http://blogs.technet.com/b/configmgrteam/archive/2014/04/03/understanding-the-adk-for-windows-8-1-update-and-configmgr-osd.aspx
    Daniel Ratliff | http://www.PotentEngineer.com
    in the article I found:
    Windows PE version 5.1 is not needed for Configuration Manager and can actually be problematic if you try to use it. Windows PE 5.0 can continue to be used to deploy Windows 8.1 Update. There is a documented process to upgrade Windows PE to version 5.1,
    but this should be considered incompatible with Configuration Manager at this time.
    So for a new installation of SCCM 2012 R2 I can install ADK 8.1 update because in contains WinPE 5.0 and option to update to 5.1. And unclear about XP, it seems XP is not supported again.
    Also fourth release was in September 2014, but article was posted in April 2014.

  • Deploy UDI Windows 10 with SCCM 2012 R2 and MDT 2013 Update 1

    Hi,
    Trying use "User-Driven Installation"  with
    SCCM 2012
    R2 CU4 and MDT
    2013 Update 1 for deploy Windows
    10.
    Created MDT Task Sequences with
    template "Client Task sequence"
    and Deployment Method "User-Driven Installation".
    When I try to deploy I have error like:
    Failed to run the last action: Error in the task sequence. Execution of task sequence failed.
    The operation cannot be completed because other resources are dependent on this resource. (Error: 00001389; Source: Windows)
    ZTI deployment failed, Return Code = 5001 InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    Unable to create WebService class InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    Command line returned 5001 InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    Process completed with exit code 5001 TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Part smsts.log
    !--------------------------------------------------------------------------------------------! TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Expand a string: WinPEandFullOS TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Executing command line: smsswd.exe /run: cscript "%deployroot%\scripts\ztierrormsg.wsf" TSManager 22.04.2015 11:36:57 1160 (0x0488)
    [ smsswd.exe ] InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    PackageID = '' InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    BaseVar = '', ContinueOnError='' InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    ProgramName = 'cscript "C:\_SMSTaskSequence\WDPackage\scripts\ztierrormsg.wsf"' InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    SwdAction = '0001' InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    Set command line: Run command line InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    Working dir 'not set' InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    Executing command line: Run command line InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    Process completed with exit code 5001 InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    Microsoft (R) Windows Script Host Version 5.12 InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    Copyright (C) Microsoft Corporation. All rights reserved. InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    Microsoft Deployment Toolkit version: 6.3.8216.1000 InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    The task sequencer log is located at X:\WINDOWS\TEMP\SMSTSLog\SMSTS.LOG. For task sequence failures, please consult this log. InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    ZTI deployment failed, Return Code = 5001 InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    Unable to create WebService class InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    Command line returned 5001 InstallSoftware 22.04.2015 11:36:57 1740 (0x06CC)
    Process completed with exit code 5001 TSManager 22.04.2015 11:36:57 1160 (0x0488)
    !--------------------------------------------------------------------------------------------! TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Failed to run the action: Error in the task sequence.
    The operation cannot be completed because other resources are dependent on this resource. (Error: 00001389; Source: Windows) TSManager 22.04.2015 11:36:57 1160 (0x0488)
    MP server http://sccm.domain.com. Ports 80,443. CRL=false. TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Setting authenticator TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Set authenticator in transport TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Sending StatusMessage TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Setting message signatures. TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Setting the authenticator. TSManager 22.04.2015 11:36:57 1160 (0x0488)
    CLibSMSMessageWinHttpTransport::Send: URL: sccm.domain.com:80 CCM_POST /ccm_system/request TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Request was successful. TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Set a global environment variable _SMSTSLastActionRetCode=5001 TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Set a global environment variable _SMSTSLastActionSucceeded=false TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Clear local default environment TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Let the parent group (Gather Logs and StateStore on Failure) decides whether to continue execution TSManager 22.04.2015 11:36:57 1160 (0x0488)
    The execution of the group (Gather Logs and StateStore on Failure) has failed and the execution has been aborted. An action failed.
    Operation aborted (Error: 80004004; Source: Windows) TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Failed to run the last action: Error in the task sequence. Execution of task sequence failed.
    The operation cannot be completed because other resources are dependent on this resource. (Error: 00001389; Source: Windows) TSManager 22.04.2015 11:36:57 1160 (0x0488)
    MP server http://sccm.domain.com. Ports 80,443. CRL=false. TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Setting authenticator TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Set authenticator in transport TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Sending StatusMessage TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Setting message signatures. TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Setting the authenticator. TSManager 22.04.2015 11:36:57 1160 (0x0488)
    CLibSMSMessageWinHttpTransport::Send: URL: sccm.domain.com:80 CCM_POST /ccm_system/request TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Request was successful. TSManager 22.04.2015 11:36:57 1160 (0x0488)
    Executing command line: X:\WINDOWS\system32\cmd.exe /k TSBootShell 22.04.2015 11:37:31 696 (0x02B8)
    The command completed successfully. TSBootShell 22.04.2015 11:37:31 696 (0x02B8)
    Successfully launched command shell. TSBootShell 22.04.2015 11:37:31 696 (0x02B8)

    MDT Updates for Windows 10 Technical Preview Build 10041
    Если Вам помог чей-либо ответ, пожалуйста, не забывайте жать на кнопку "Предложить как ответ" или "Пометить как ответ".
    http://zalozny.com.ua

  • SCCM 2012 R2 and client content sharing on Windows 7 Pro

    Is it possible to use "Allow clients to share content with other clients on the same subnet" option on Windows 7 Pro clients? It's bit confusing  because based on documentation, branch cache is only available on Windows 7 Enterprise and
    Ultimate editions. Why does Windows 7 Pro have branch cache service when it's not usable?

    Hi,
    Is Branch Cache working with Windows 7 Professional?
    No, it will not work with Windows 7 professional . Only Windows® 7 Enterprise and Windows® 7 Ultimate will support it.
    We can confirm that form the official link below:
    Client computer. A computer at a branch office that is running either Windows 7 Enterprise or Windows 7 Ultimate and that has BranchCache enabled.
    BranchCache Overview
    http://technet.microsoft.com/en-us/library/ee307962(WS.10).aspx
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Software Update Point doesn't show Win 2012 R2 and Windows 8.1 updates

    I started deploying Windows 2012 R2 Datacenter servers and some Windows 8.1 workstations. I wanted to make sure that my Software Update Point was downloading updates available to those OS's and after going in to Administration -> Overview -> Site Configuration
    -> Sites -> Configure Site Components -> Software Update Point, I notice that those OS's weren't available to select. 
    I then did some searches on the web and thought my problem was two fold:
    1 - I was using SCCM 2012 SP1. 
    2 - My SCCM 2012 Software Update Point was on a Win 2008 R2 server
    So the first thing I did was upgrade from SCCM 2012 SP1 to SCCM 2012 R2. I then created a Windows 2012 R2 Datacenter server and installed WSUS on it. I then added the server as a Site System Server, added the Software Update Point to it and configured it.
    Unfortunately, this still didn't help me as you can see from the screen shots below:
    What am I doing wrong and what needs to be done to have all the updated Operating Systems and Microsoft Software added to my Product list?
    Thanks... Frank

    To follow on to narcoticoo's statement, have you actually initiated a catalog sync from within the ConfigMgr console yet? If so, has it completed successfully (you can check the moniotring workspace or you can watch the wsyncmgr.log).
    Jason | http://blog.configmgrftw.com
    Jason...
    I just ran a Synchronize Software Updates from ConfigMgr Console. I then went Monitoring -> Software Update Point Sync Status. It's showing my new WSUS server ( 2012 R2 ) but it's not showing any updates are being sync'd through it. See this screen shot:
    I then went to the wsyncmgr.log file on my site server which is the OLD WSUS server ( Win 2008 R2 ) and say this:
    STATMSG: ID=6703 SEV=E LEV=M SOURCE="SMS Server" COMP="SMS_WSUS_SYNC_MANAGER" SYS=PREP-SCCM12.<domain.org> SITE=STA PID=5224 TID=4028 GMTDATE=Wed Feb 26 19:00:40.236 2014 ISTR0="getSiteUpdateSource" ISTR1="WSUS update source not found on site STA. Please refer to WCM.log for configuration error details." ISTR2="" ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=0 $$<SMS_WSUS_SYNC_MANAGER><02-26-2014 14:00:40.236+300><thread=4028 (0xFBC)>
    Sync failed. Will retry in 60 minutes $$<SMS_WSUS_SYNC_MANAGER><02-26-2014 14:00:40.279+300><thread=4028 (0xFBC)>
    Setting sync alert to active state on site STA $$<SMS_WSUS_SYNC_MANAGER><02-26-2014 14:00:40.313+300><thread=4028 (0xFBC)>
    Sync time: 0d00h00m00s $$<SMS_WSUS_SYNC_MANAGER><02-26-2014 14:00:40.360+300><thread=4028 (0xFBC)>
    Deleting file \\?\UNC\prep-dpsccm12\WSUS Updates\Win 7 Updates up to Aug 2012\0048da55-f46f-4452-b4c1-37c0f295333b\IE9-langpack-Windows7-x86-xho.exe, FAILED, Win32 Error = 5 $$<SMS_WSUS_SYNC_MANAGER><02-26-2014 14:00:41.042+300><thread=4028 (0xFBC)>
    Failed to delete orphaned content folder \\prep-dpsccm12\WSUS Updates\Win 7 Updates up to Aug 2012, error 0x5 $$<SMS_WSUS_SYNC_MANAGER><02-26-2014 14:00:41.067+300><thread=4028 (0xFBC)>
    Deleting file \\?\UNC\prep-dpsccm12\WSUS Updates\Win2k8 Updates Until Aug 2012\000f8a0a-825c-457b-a15b-57ade145a09b\windows6.0-kb2653956-x64.cab, FAILED, Win32 Error = 5 $$<SMS_WSUS_SYNC_MANAGER><02-26-2014 14:00:41.119+300><thread=4028 (0xFBC)>
    Failed to delete orphaned content folder \\prep-dpsccm12\WSUS Updates\Win2k8 Updates Until Aug 2012, error 0x5 $$<SMS_WSUS_SYNC_MANAGER><02-26-2014 14:00:41.144+300><thread=4028 (0xFBC)>
    Deleting file \\?\UNC\prep-dpsccm12\WSUS Updates\Win 7 Updates for Sept 2012\10f3ec1c-f096-4a82-ae41-440ba5328467\Windows6.1-RTM-Client-NEUTRAL-X86.EXE, FAILED, Win32 Error = 5 $$<SMS_WSUS_SYNC_MANAGER><02-26-2014 14:00:41.173+300><thread=4028 (0xFBC)>
    Failed to delete orphaned content folder \\prep-dpsccm12\WSUS Updates\Win 7 Updates for Sept 2012, error 0x5 $$<SMS_WSUS_SYNC_MANAGER><02-26-2014 14:00:41.199+300><thread=4028 (0xFBC)>
    Deleting file \\?\UNC\prep-dpsccm12\WSUS Updates\XP Updates Until Sept 30\17165524-99fa-49f7-91e6-457d43d4a48e\Windows-KB890830-V4.12.exe, FAILED, Win32 Error = 5 $$<SMS_WSUS_SYNC_MANAGER><02-26-2014 14:00:41.228+300><thread=4028 (0xFBC)>
    Failed to delete orphaned content folder \\prep-dpsccm12\WSUS Updates\XP Updates Until Sept 30, error 0x5 $$<SMS_WSUS_SYNC_MANAGER><02-26-2014 14:00:41.254+300><thread=4028 (0xFBC)>
    It appears to me that when doing a Sync, it's still trying to use my OLD WSUS server instead of my new one. I removed the Software Update Point from the OLD WSUS server and uninstalled WSUS from it. I'm not sure why it's still trying to sync from the old
    server rather than the new one. Any ideas?
    Thanks... Frank

  • SCCM 2012 SP1 and MDT 2012 Task Sequence Templates, MDT File/Settings Packages

    We're setting up SCCM 2012 integrated with MDT 2012 for our OSD. My main issue is finding actual reference material for the MDT task sequence templates when integrated with SCCM. The MDT documentation has a lot of information on variables and task sequences
    outside of SCCM integration. 
    One thing I'd love to find information on is what's actually going on during an MDT Client Task Sequence template. I found this http://social.technet.microsoft.com/Forums/en-US/645a77b2-5be6-431d-818c-57d24b1435cc/understanding-mdt-task-sequence?forum=configmgrosd but
    it doesn't delve into the kind of detail I'm looking for. I can dig up information through the MDT reference material on some things, but I just can't find anything out there that actually walks you through an SCCM/MDT task sequence template. For instance,
    under State Restore what is being referenced in Install Software with base variable name PACKAGES, vs Install Applications and base variable name COALESCED APPS. And, where are you supposed to put these applications? That's just a specific example, I'm hoping
    to find some kind of walkthrough.
    Two things I'm hazy on are the MDT packages. What exactly are the MDT Settings Package, and the MDT Files Package? What are they used for? What benefits do you get out of using them? And, how exactly do you use them? I know one of them has something to do
    with customsettings.ini, but what's the point of using SCCM with MDT if you still have to muck around in the customsettings.ini file?
    Either way, it seems like there are a lot of references to SCCM task sequences, and a lot of references to MDT task sequences. But, not together. Which is a bit annoying since the MDT-integrated task sequence templates are very obviously different than either
    SCCM or MDT by itself. Any help would be appreciated, even just information on where to look. Maybe I'm just really bad at finding reference material for SCCM/MDT. Thanks. 

    When MDT integrated with SCCM, We need the following MDT components to be created:
    MDT Boot image
    MDT Toolkit Files
    MDT Settings
    The MDT boot image (for example) gives you extra abilities over the standard ConfigMgr boot image such as the ability to display a HTA Refer here:
    http://www.windows-noob.com/forums/index.php?/forum/98-frontends-and-web-services/
    MDT Files once created, you will find UDIWizard_Config.Xml file in which you can start User driven Installation OSD using UDI designer.
    Refer these links for better understanding:
    http://www.windows-noob.com/forums/index.php?/topic/5131-using-sccm-2012-rc-in-a-lab-part-16-integrating-mdt-2012-rc1-with-configuration-manager-2012/
    http://www.windows-noob.com/forums/index.php?/topic/5221-using-sccm-2012-rc-in-a-lab-part-17-using-mdt-2012-rc1-within-configuration-manager-2012/
    http://www.windows-noob.com/forums/index.php?/topic/5250-using-sccm-2012-rc-in-a-lab-part-18-deploying-a-udi-client-task-sequence-with-mdt-2012-rc1-integrated-in-configuration-manager-2012/
    Thanks, Prabha G
    Thanks for the quick reply. But, what about the MDT Settings Package? Also, both have a pretty big folder structure for each package. Surely it does more than just provide a couple xml and ini files? I'm not looking for anyone to spoon-feed me the information,
    but at least a pointer in the right direction for finding the reference material. It seems for SCCM/MDT integration you have to go all over the place finding scraps of information to put together. 
    Also, any info on the SCCM/MDT task sequence templates? Thanks. 

  • SCCM 2012 Client and Workstation Audio and Video Problems

    SCCM 2012 SP1 environment.
    We have pushed out the SCCM Client successfully to our systems - however we have found that on some computers the SCCM Client is causing an audio/video problem - specifically it appears to be with computers that connect monitors via DVI.  As an example,
    on my laptop (Dell e6420, Win7 x64) I have a docking station that connects my laptop to 2 external monitors.  With the SCCM Client installed I cannot listen to music or watch videos - the result is an unusable choppiness/stuttering listening to music
    and with a video the audio and video get out of sync.  As well, my mouse no longer functions smoothly - it jumps around.  This happens whether accessing content from a website or simply a local file on my computer.  If I uninstall the SCCM client,
    the issue goes away entirely.  I have tried disabling the SMS and Remote control services but doing so does not resolve the issue, only a client uninstall. Note that this only happens when the laptop is on the docking station - with DVI - it doesn't
    happen when the laptop is running without an external monitor or if plugged into an HDMI output device.
    At first we believed this was limited to this model of laptop in our environment (Win8 or Win7 - both result in the same problem), but now we are hearing about "audio and video issues" on Dell 990 workstations as well.  I believe these stations
    have DVI connected monitors.  Driver updates do not appear to resolve the issue.
    Has anyone experienced this in their environment?  Note that this happens on imaged workstations and workstations installed from a vanilla Windows 7 or 8 CD.

    Try installing the client without Silverlight and see if it helps (this is only used for the Application Catalog).
    ccmsetup.exe /skipprereq:silverlight.exe
    Gerry Hampson | Blog:
    www.gerryhampsoncm.blogspot.ie | LinkedIn:
    Gerry Hampson | Twitter:
    @gerryhampson

Maybe you are looking for

  • How to find out if running 64 bit jvm

    Hi all, I have an application which can be run using 64 bit JNI libraries, or 32 bit libraries depending on the command line parameters. I want to know if there is any way for me to find out if the JVM is running in 64 bit mode (the -d64 parameter wa

  • Hard Disk filling up on AIX

    I am running Oracle 9.2.0.1.0 on AIX 5.5.1. We are experiencing problems in that our /ora1 file system, which is the mount point where Oracle is installed and our one database has its control files, system tablespace, and undo tablespace (the other d

  • Getting full 1080p to a Sharp Aquos 42'' HD LCD TV

    Okay, I've been struggling and struggling with this one for a good month or two and I have pretty much use up all my lifelines except the apple forums I have a Sharp Aquos 42'' LCD HDTV that is 1080p capable, and has 2 HDMI inputs. I have been using

  • ROOP ROOP ROOOOOP: What's that red circle thing?

    now i am getting panicky. i see my iWeb icon in my Dock. That icon has a RED DOT WITH A WHITE #1 in it. What does this mean? I looked over my iWeb pages but see nothing that tweets a bell. PLEASE, is something going hot on my iWeb? Is it going south?

  • What SAP modules are required for insuance sector

    what SAP modules are required for insuance sector