SCCM 2012 SP1 CU5 - Unknown error code when deploying Bitlocker encryption (happens during check for Bitlocker partition)

Hi
It says in the smsts.log file from the laptop:
Evaluating a WMI condition expression TSManager 03-02-2015 13:34:58 7304 (0x1C88)
Expand a string: root\cimv2 TSManager 03-02-2015 13:34:58 7304 (0x1C88)
Expand a string: SELECT * FROM Win32_DiskPartition WHERE DiskIndex = 0 and Index = 0 and Size = 100 TSManager 03-02-2015 13:34:58 7304 (0x1C88)
The condition for the action (Create BitLocker partition) is evaluated to be true TSManager 03-02-2015 13:34:58 7304 (0x1C88)
Expand a string: smsswd.exe /run: cmd.exe /c bdeHdCfg.exe -target default -size 300 -quiet TSManager 03-02-2015 13:34:58 7304 (0x1C88)
Expand a string:  TSManager 03-02-2015 13:34:58 7304 (0x1C88)
Start executing the command line: smsswd.exe /run: cmd.exe /c bdeHdCfg.exe -target default -size 300 -quiet TSManager 03-02-2015 13:34:58 7304 (0x1C88)
!--------------------------------------------------------------------------------------------! TSManager 03-02-2015 13:34:58 7304 (0x1C88)
Expand a string: WinPEandFullOS TSManager 03-02-2015 13:34:58 7304 (0x1C88)
Executing command line: smsswd.exe /run: cmd.exe /c bdeHdCfg.exe -target default -size 300 -quiet TSManager 03-02-2015 13:34:58 7304 (0x1C88)
Creation event received for process 7976 mtrmgr 03-02-2015 13:34:58 4564 (0x11D4)
[ smsswd.exe ] InstallSoftware 03-02-2015 13:34:58 4668 (0x123C)
PackageID = '' InstallSoftware 03-02-2015 13:34:58 4668 (0x123C)
BaseVar = '', ContinueOnError='' InstallSoftware 03-02-2015 13:34:58 4668 (0x123C)
ProgramName = 'cmd.exe /c bdeHdCfg.exe -target default -size 300 -quiet' InstallSoftware 03-02-2015 13:34:58 4668 (0x123C)
SwdAction = '0001' InstallSoftware 03-02-2015 13:34:58 4668 (0x123C)
Getting linked token InstallSoftware 03-02-2015 13:34:58 4668 (0x123C)
failed to get the linked token information. It may not be available. Error 1312 InstallSoftware 03-02-2015 13:34:58 4668 (0x123C)
Process ID 7976 is for process C:\Windows\CCM\smsswd.exe mtrmgr 03-02-2015 13:34:58 4564 (0x11D4)
No matching rule found for process 7976 mtrmgr 03-02-2015 13:34:58 948 (0x03B4)
Working dir 'not set' InstallSoftware 03-02-2015 13:34:58 4668 (0x123C)
Executing command line: Run command line InstallSoftware 03-02-2015 13:34:58 4668 (0x123C)
Creation event received for process 7452 mtrmgr 03-02-2015 13:34:58 4564 (0x11D4)
Process ID 7452 is for process C:\Windows\system32\cmd.exe mtrmgr 03-02-2015 13:34:59 4564 (0x11D4)
Found match against RuleID LGR00188 mtrmgr 03-02-2015 13:34:59 948 (0x03B4)
Creation event received for process 7940 mtrmgr 03-02-2015 13:34:59 4564 (0x11D4)
Tracked usage for process 7452 mtrmgr 03-02-2015 13:34:59 948 (0x03B4)
Process ID 7940 is for process C:\Windows\system32\conhost.exe mtrmgr 03-02-2015 13:34:59 4564 (0x11D4)
Creation event received for process 3104 mtrmgr 03-02-2015 13:34:59 4564 (0x11D4)
Found match against RuleID LGR00183 mtrmgr 03-02-2015 13:34:59 948 (0x03B4)
Tracked usage for process 7940 mtrmgr 03-02-2015 13:34:59 948 (0x03B4)
Process ID 3104 is for process C:\Windows\system32\BdeHdCfg.exe mtrmgr 03-02-2015 13:34:59 4564 (0x11D4)
Creation event received for process 7552 mtrmgr 03-02-2015 13:34:59 4564 (0x11D4)
No matching rule found for process 3104 mtrmgr 03-02-2015 13:34:59 948 (0x03B4)
Process ID 7552 is for process C:\Windows\System32\vdsldr.exe mtrmgr 03-02-2015 13:34:59 4564 (0x11D4)
Creation event received for process 7152 mtrmgr 03-02-2015 13:34:59 4564 (0x11D4)
No matching rule found for process 7552 mtrmgr 03-02-2015 13:34:59 948 (0x03B4)
Process ID 7152 is for process C:\Windows\System32\vds.exe mtrmgr 03-02-2015 13:34:59 4564 (0x11D4)
No matching rule found for process 7152 mtrmgr 03-02-2015 13:34:59 948 (0x03B4)
Termination event received for process 3104 mtrmgr 03-02-2015 13:35:00 4564 (0x11D4)
Termination event received for process 7452 mtrmgr 03-02-2015 13:35:00 4564 (0x11D4)
Process completed with exit code 3231711234 InstallSoftware 03-02-2015 13:35:00 4668 (0x123C)
Termination event received for process 7940 mtrmgr 03-02-2015 13:35:00 4564 (0x11D4)
BitLocker Drive Preparation Tool version 6.1.7601 InstallSoftware 03-02-2015 13:35:00 4668 (0x123C)
InstallSoftware 03-02-2015 13:35:00 4668 (0x123C)
opyright (C) 2006-2008 Microsoft Corporation. InstallSoftware 03-02-2015 13:35:00 4668 (0x123C)
InstallSoftware 03-02-2015 13:35:00 4668 (0x123C)
InstallSoftware 03-02-2015 13:35:00 4668 (0x123C)
Command line returned 3231711234 InstallSoftware 03-02-2015 13:35:00 4668 (0x123C)
Termination event received for process 7976 mtrmgr 03-02-2015 13:35:01 4564 (0x11D4)
Process completed with exit code 3231711234 TSManager 03-02-2015 13:35:01 7304 (0x1C88)
!--------------------------------------------------------------------------------------------! TSManager 03-02-2015 13:35:01 7304 (0x1C88)
Failed to run the action: Create BitLocker partition.
Unknown error (Error: C0A00002; Source: Unknown) TSManager 03-02-2015 13:35:01 7304 (0x1C88)
Set authenticator in transport TSManager 03-02-2015 13:35:01 7304 (0x1C88)
Set a global environment variable _SMSTSLastActionRetCode=-1063256062 TSManager 03-02-2015 13:35:01 7304 (0x1C88)
Set a global environment variable _SMSTSLastActionSucceeded=false TSManager 03-02-2015 13:35:01 7304 (0x1C88)
Clear local default environment TSManager 03-02-2015 13:35:01 7304 (0x1C88)
Failed to run the action: Create BitLocker partition. Execution has been aborted TSManager 03-02-2015 13:35:01 7304 (0x1C88)
Set authenticator in transport TSManager 03-02-2015 13:35:01 7304 (0x1C88)
Failed to run the last action: Create BitLocker partition. Execution of task sequence failed.
Unknown error (Error: C0A00002; Source: Unknown) TSManager 03-02-2015 13:35:01 7304 (0x1C88)
Set authenticator in transport TSManager 03-02-2015 13:35:01 7304 (0x1C88)
Termination event received for process 6188 mtrmgr 03-02-2015 13:35:03 4564 (0x11D4)
Termination event received for process 7552 mtrmgr 03-02-2015 13:35:06 4564 (0x11D4)
Task Sequence Engine failed! Code: enExecutionFail TSManager 03-02-2015 13:35:07 7304 (0x1C88)
**************************************************************************** TSManager 03-02-2015 13:35:07 7304 (0x1C88)
Task sequence execution failed with error code 80004005 TSManager 03-02-2015 13:35:07 7304 (0x1C88)

Hi Jason
See below. The problem is that on some of our laptops not anywhere geographically close to our IT department, the laptop has been setup with 2 partitions and on some only with 1 partition (we used another deployment system 2 years ago), so I am trying
to prepare all our corporate laptops for Bitlocker encryption. The reason why I made this task sequence was to hit all those laptops that is not being reinstalled / installed again in the near future.
Do you have any suggestions, should it help to remove the cmd.exe /c in front of the Bitlocker cmd line ?
We have tried the MBAM solution, but in my opinion too many problems with the MBAM client.

Similar Messages

  • Best practice - Heartbeat discovery and Clear Install Flag settings (SCCM client) - SCCM 2012 SP1 CU5

    Dear All,
    Is there any best practice to avoid having around 50 Clients, where the Client version number shows in the right side, but client doesn't show as installed, see attached screenshot.
    SCCM version is 2012 SP1 CU5 (5.00.7804.1600), Server, Admin console have been upgraded, clients is being pushed to SP1 CU5.
    Following settings is set:
    Heartbeat Discovery every 2nd day
    Clear Install Flag maintenance task is enabled - Client Rediscovery period is set to 21 days
    Client Installation settings
    Software Update-based client installation is not enabled
    Automatic site-wide client push installation is enabled.
    Any advise is appreciated

    Hi,
    I saw a similar case with yours. They clients were stuck in provisioning mode.
    "we finally figured out that the clients were stuck in provisioning mode causing them to stop reporting. There are two registry entries we changed under [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\CCM\CcmExec]:
    ProvisioningMode=false
    SystemTaskExcludes=*blank*
    When the clients were affected, ProvisioningMode was set to true and SystemTaskExcludes had several entries listed. After correcting those through a GPO and restarting the SMSAgentHost service the clients started reporting again."
    https://social.technet.microsoft.com/Forums/en-US/6d20b5df-9f4a-47cd-bdc3-2082c1faff58/some-clients-have-suddenly-stopped-reporting?forum=configmanagerdeployment
    Best Regards,
    Joyce
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

  • Ipod getting unknown error code when plugging it in to itunes 9

    My ipod was restored with itunes 9, but after it's done it wont get recognized with itunes. Itunes says there is a unknown error code(OxE800000A). How do i get itunes to recognize my ipod. I have 3.1.2 firmware, its a 2nd generation, 8gb.

    Hi Demo, thank you for your suggestions.
    I've tried updating in the following conditions:
    1. "Over The Air" at one location;
    2. On a Windows computer running the latest version of iTunes at the same location;
    3. On Mavericks (10.9.4) running the latest version of iTunes (11.4 (18)) at another location;
    4. On Mavericks, latest iTunes over a VPN with a server location in US;
    5. On Mavericks, using a 3G connection shared from an iPhone;
    6. On Yosemite developer preview with a previous version of iTunes at the same location.
    I got the same results in most cases except for an occasional error with code 9; I'll try again in other conditions.
    Interestingly enough, I've successfully updated my devices to iOS 7.1.2 and to iOS8 GM without any issues at the same location but, of course, no two conditions are exactly the same

  • SCCM 2012 SP1 CU5 PATCH Property

    I've recently updated my site from SCCM SP1 to SCCM SP1 CU5 (http://support.microsoft.com/kb/2978017) successfully.  I've verified through the registry that the Server is on CULevel 5 and
    the consoles have been updated.  In addition I have verified the MSP applies successfully and the clients report 5.00.7804.1600 for a client push through SCCM or manually running the patch.  The problem is during OSD.
    What I did was go to my original Client install folder under SMS_XXX folder.  I created a folder called "hotfixes" and then inside there a folder called "amd64" and "x86".  Inside their I copied "kb2978017.msp"
    to the X86 and the AMD64 folder.  I then updated the distribution points for the original client package (so they receive the new hotfixes folder I added).  From there I went in the task sequence and on the "Setup Windows and Configuration Manager"
    step I added the "Installation Properties" line as shown below:
    SMSMP=XXX.xxx.com PATCH="C:\_SMSTaskSequence\OSD\XXX00003\hotfixes\%PROCESSOR_ARCHITECTURE%\kb2978017.msp"
    When the computer finishes imaging it still reports "5.00.7804.1000" and not the .1600 version.  All the guides I've seen mentioned using the PATCH= property and pointing it to the correct package ID number (I verified this).  Not sure
    what I'm doing wrong.  I did see an alternative of a step to manually copy the patch to the local drive with xcopy and then the Setup CM Client step to just call the local machine for the patch instead off this "C:\_SMSTaskSequence".  What
    has other peoples experience been?  
    Be kind and Mark as Answer if I helped.

    Yes, I did copy the hotfixes to the client source folder (I checked the data source of the package in SCCM to ensure I was updating files/folders in correct directory) and then I right clicked the package in SCCM and selected Updated Distribution Points
    and verified they did get updated successfully.  I checked the CCMSetup.log after a machine is imaged and it reports at the top of the log the command run to install SCCM Client and it just shows CCMSetup.exe without my SMSMP= property or the PATCH= property.
      Its like the client install doesn't even recognize the commands I've used in the task sequence.  Attached is a picture of the step in SCCM with the Server and Site name blanked out for obvious reasons:
    CCMSETUP.log here : https://drive.google.com/file/d/0Bzodkg-HoMIhMHMwMnJZbkxpUHc/edit?usp=sharing
    Be kind and Mark as Answer if I helped.

  • Unknown error occurs when I connect my iphone to itunes for the first time, what does that mean

    Everytime I connect my iphone to my laptop and start up itnes get an error messaage stating that an error has occurred and my phone can not be read

    Read here:
    http://support.apple.com/kb/ht1207

  • SCCM Device Query for SCEP 2012 SP1 CU5

    Dear all,
    I want to create a device query rule for SCEP client agent installed machines , SCCM version we are using SCCM 2012 SP1 CU5. If any one has the query , please let me know.
    Thanks,
    Sengottuvel M

    select distinct SMS_R_System.Name from SMS_R_System inner join SMS_G_System_SYSTEM_ENCLOSURE on SMS_G_System_SYSTEM_ENCLOSURE.ResourceID = SMS_R_System.ResourceId inner join SMS_G_System_ADD_REMOVE_PROGRAMS on SMS_G_System_ADD_REMOVE_PROGRAMS.ResourceID = SMS_R_System.ResourceId full join SMS_G_System_ADD_REMOVE_PROGRAMS_64 on SMS_G_System_ADD_REMOVE_PROGRAMS_64.ResourceID = SMS_R_System.ResourceId where (SMS_G_System_ADD_REMOVE_PROGRAMS.DisplayName = "System Center 2012 Endpoint Protection" or SMS_G_System_ADD_REMOVE_PROGRAMS_64.DisplayName = "System Center 2012 Endpoint Protection")

  • DP Job queue manager not working- SCCM 2012 SP1

    
    I am getting below error when trying to open DP job queue manager in sccm 2012 SP1
    Please find the details information
    see the end of this message for details on invoking
    just-in-time (JIT) debugging instead of this dialog box.
    ************** Exception Text **************
    Microsoft.ConfigurationManagement.ManagementProvider.WqlQueryEngine.WqlQueryException: The SMS Provider reported an error. ---> System.Management.ManagementException:
    Invalid query
       at System.Management.ManagementException.ThrowWithExtendedInfo(ManagementStatus errorCode)
       at System.Management.ManagementObjectCollection.ManagementObjectEnumerator.MoveNext()
       at Microsoft.ConfigurationManagement.ManagementProvider.WqlQueryEngine.WqlQueryResultsObject.<GetEnumerator>d__0.MoveNext()
       --- End of inner exception stack trace ---
       at Microsoft.ConfigurationManagement.ManagementProvider.WqlQueryEngine.WqlQueryResultsObject.<GetEnumerator>d__0.MoveNext()
       at DPJobMgr.Form1.SummaryRefresh_Click_real(Object sender, EventArgs e)
       at DPJobMgr.Form1.SummaryRefresh_Click(Object sender, EventArgs e)
       at System.Windows.Forms.TabControl.OnSelectedIndexChanged(EventArgs e)
       at System.Windows.Forms.TabControl.WmSelChange()
       at System.Windows.Forms.TabControl.WndProc(Message&
    m)
       at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd,
    Int32 msg, IntPtr wparam, IntPtr lparam)
    ************** Loaded Assemblies **************
    mscorlib
        Assembly Version: 4.0.0.0
        Win32 Version: 4.0.30319.1008 (RTMGDR.030319-1000)
        CodeBase: file:///C:/Windows/Microsoft.NET/Framework64/v4.0.30319/mscorlib.dll
    DPJobMgr
        Assembly Version: 5.0.0.0
        Win32 Version: 5.0.7958.1000
        CodeBase: file:///C:/Program%20Files%20(x86)/ConfigMgr%202012%20Toolkit%20R2/ServerTools/DPJobMgr.exe
    System.Windows.Forms
        Assembly Version: 4.0.0.0
        Win32 Version: 4.0.30319.1002 built by: RTMGDR
        CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Windows.Forms/v4.0_4.0.0.0__b77a5c561934e089/System.Windows.Forms.dll
    System.Drawing
        Assembly Version: 4.0.0.0
        Win32 Version: 4.0.30319.1001 built by: RTMGDR
        CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Drawing/v4.0_4.0.0.0__b03f5f7f11d50a3a/System.Drawing.dll
    System
        Assembly Version: 4.0.0.0
        Win32 Version: 4.0.30319.1001 built by: RTMGDR
        CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System/v4.0_4.0.0.0__b77a5c561934e089/System.dll
    Microsoft.ConfigurationManagement.ManagementProvider
        Assembly Version: 5.0.0.0
        Win32 Version: 5.0.7958.1000
        CodeBase: file:///C:/Program%20Files%20(x86)/ConfigMgr%202012%20Toolkit%20R2/ServerTools/Microsoft.ConfigurationManagement.ManagementProvider.DLL
    System.Core
        Assembly Version: 4.0.0.0
        Win32 Version: 4.0.30319.233 built by: RTMGDR
        CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Core/v4.0_4.0.0.0__b77a5c561934e089/System.Core.dll
    System.Data.Linq
        Assembly Version: 4.0.0.0
        Win32 Version: 4.0.30319.1015
        CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Data.Linq/v4.0_4.0.0.0__b77a5c561934e089/System.Data.Linq.dll
    System.Management
        Assembly Version: 4.0.0.0
        Win32 Version: 4.0.30319.1 (RTMRel.030319-0100)
        CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Management/v4.0_4.0.0.0__b03f5f7f11d50a3a/System.Management.dll
    AdminUI.WqlQueryEngine
        Assembly Version: 5.0.0.0
        Win32 Version: 5.0.7958.1000
        CodeBase: file:///C:/Program%20Files%20(x86)/ConfigMgr%202012%20Toolkit%20R2/ServerTools/AdminUI.WqlQueryEngine.DLL
    System.Configuration
        Assembly Version: 4.0.0.0
       Win32 Version: 4.0.30319.1015 (RTMGDR.030319-1000)
        CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Configuration/v4.0_4.0.0.0__b03f5f7f11d50a3a/System.Configuration.dll
    System.Xml
        Assembly Version: 4.0.0.0
        Win32 Version: 4.0.30319.1015 built by: RTMGDR
        CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_MSIL/System.Xml/v4.0_4.0.0.0__b77a5c561934e089/System.Xml.dll
    System.Data
        Assembly Version: 4.0.0.0
        Win32 Version: 4.0.30319.237 (RTMGDR.030319-2300)
        CodeBase: file:///C:/Windows/Microsoft.Net/assembly/GAC_64/System.Data/v4.0_4.0.0.0__b77a5c561934e089/System.Data.dll
    ************** JIT Debugging **************
    To enable just-in-time (JIT) debugging, the .config file for this
    application or computer (machine.config) must have the
    jitDebugging value set in the system.windows.forms section.
    The application must also be compiled with debugging
    enabled.
    For example:
    <configuration>
        <system.windows.forms jitDebugging="true"
    />
    </configuration>
    When JIT debugging is enabled, any unhandled exception
    will be sent to the JIT debugger registered on the computer
    rather than be handled by this dialog box.

    Hi,
    That is as expected, the new tools require Configuration Manager 2012 R2 to work. From the download page of Configuration Manager 2012 R2 toolkit.
    "Note: Items with an * are new in the R2 Toolkit and require Microsoft System Center 2012 R2 Configuration Manager for full functionality. 
    Server Based Tools
    * DP Job Manager - A tool that helps troubleshoot and manage ongoing content distribution jobs to Configuration Manager distribution points.
    * Collection Evaluation Viewer - A tool that assists in troubleshooting collection evaluation related issues by viewing collection evaluation details.
    * Content Library Explorer - A tool that assists in troubleshooting issues with and viewing the contents of the content library"
    So you need to upgrade to R2 before you can use the new tools.
    Regards,
    Jörgen
    -- My System Center blog ccmexec.com -- Twitter
    @ccmexec

  • SCCM 2012 SP1 OSD in 802.1X environment

    Dears, 
    we have SCCM 2012 SP1 CU5, and the network team has enabled the CISCO port security (802.1X network authentication) on the desktops VLAN and OSD is not working since then until port security is removed. i've seen some guides regarding how to make SCCM 2007
    OSD, WinPE 3.0 and 802.1X work together like : http://myitforum.com/cs2/blogs/lakey81/archive/2011/07/06/configuring-802-1x-network-authentication-for-winpe-3-0-and-configmgr-deployments.aspx  , but ot's very confusing.
    does anybody have the same scenario with SCCM 2012, WinPE 5.0, and 802.1X . please help me.

    Hello,
    What confused you here? 802.1X authentication is to authenticate before sending network packages. That is why we need import netwrok profile to win pe for anthentication. The point is authenticate, so I think it won't be any difference between
    ConfigMgr 2012 and 2007.          
    Another good article here:
    http://blogs.technet.com/b/deploymentguys/archive/2010/03/02/adding-support-for-802-1x-to-winpe.aspx
    Please also pay attention to the shared document in the blog.
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

  • SCCM 2012 SP1 errors when downloading updates

    Currently using SCCM 2012 SP1 with CU2 and I am having some update download issue with Automatic Deployment Rules.
    The Environment is:
      Server 2008 R2
      SCCM 2012 SP1 CU2 (Upgraded from SCCM 2012 CU2)
    I created an Automatic Deployment Rule for Adobe Flash. Since I was having the same issue with Adobe Reader, when I published via SCUP to WSUS I chose not to sign the updates.
    After publishing to WSUS I then sync SCCM, I see the updates and then in the ADR I had it download the updates and I see this error:
    Authentication of file C:\Windows\TEMP\CABDEC5.tmp failed, error 0x800b0004 Software Updates Patch Downloader 8/15/2013 6:49:43 PM 3712 (0x0E80)
    ERROR: DownloadContentFiles() failed with hr=0x80073633 Software Updates Patch Downloader 8/15/2013 6:49:43 PM 6876 (0x1ADC)
    Failed to download the update from internet. Error = 13875 SMS_RULE_ENGINE 8/15/2013 6:49:43 PM 6876 (0x1ADC)
    Failed to download ContentID 16845337 for UpdateID 16841530. Error code = 13875 SMS_RULE_ENGINE 8/15/2013 6:49:43 PM 6876 (0x1ADC)
    Now the funny thing is if I go to the update itself within update group that Flash is a member I can right click it and choose download and the error doesn't occur.
    I observed that the UNC path for ADR Adobe flash, when the rule is ran, is populated with folders that have a name something like 44738297895427890.1 or 423154325378u867234789.1. I have come to realize that those are failed downloads. So for the
    heck of it I then right clicked the update itself and chose download and it downloaded without issue. Now I'm guessing that when I chose to download directly from the update maybe the system is getting the update from adobe and not from wherever the rule was
    trying to get it from.  I then see the .1 removed from the directory name and there are updates within them.
    Just for clarity here are the steps I go through from SCUP to Syncing...
    Log in to WSUS server
    Run SCUP as administrator
    Get notified there are updates from Adobe and let SCUP download updates
    Find the updates the specify the following publishing options
    Full Content
    Sign all software updates with a new publishing certificate .... (Is this necessary by the way?)
    Then click Next
    After that's done I then go to SCCM Manager Console and go to Software Updates and right click to Synchronize them.
    After that's done then I run the ADR for Adobe Flash and when it goes to download the updates that's when the error occurs.
    What am I missing?
    Also, while I wait for help I just recently added the WSUS SCUP certificate to the SCCM server to see if by chance that fixes stuff. If it does then I'll post the results of adding the certificate to the SCCM server.
    One other thing, is there a way to delete updates? When I was having this issue in the past, I went in to SCUP I marked the updates as expired and then deleted the updates. Went to SCCM and synchronized the updates and they went from not expired to expired
    then I waited, maybe 30 days or so before I could add the updates back in.
    Thanks for the help!

    Yes, I know this is an old post, but I’m trying to clean them up. Did you solve this problem, if so what was the solution?
    Have you seen the note at the bottom of this page about this error?
    http://technet.microsoft.com/en-us/library/bb932193.aspx
    Garth Jones | My blogs: Enhansoft and
    Old Blog site | Twitter:
    @GarthMJ

  • System task 'policyevaluator_unlock ' returned error code 0x8000fff in windows pacth deployment on windows 7 by sccm 2012 Sp1

    hi All,
    I have faced mentioned error in Win7's ccmexec.log file doing windows pacth deployment on windows 7 by sccm 2012 Sp1
    system task 'policyevaluator_unlock ' returned error code 0x8000fff
    Kirpal Singh

    Thanks for reporting this symptom. We investigated and found that this error occurs when user unlocks the workstation. Due to this error, ccmexec service doesn’t request for user required policies when user
    unlocks the workstation. We will investigate and address this symptom. Other than user unlock, all other user policy scenarios will be functioning as expected. The client will process user policies when user logs on as well as in the regular user policy polling
    schedule”.
    BC

  • Software Update error - SCCM 2012 SP1

    HI,
    I have SCCM 2012 SP1 installed on Windows server 2008 R2 server. I have configured SUP role and tried sync from sccm console. I get the below error.
    LOg:
    WSUS sync running~  $$<SMS_WSUS_CONFIGURATION_MANAGER><01-30-2014 14:11:42.047+00><thread=3840 (0xF00)>
      WSUS sync running~  $$<SMS_WSUS_CONFIGURATION_MANAGER><01-30-2014 14:12:42.255+00><thread=3840 (0xF00)>
    Microsoft.SystemsManagementServer.WSUS.WSUSMSPException: WSUS sync failed with UssCommunicationError: ~~   at Microsoft.SystemsManagementServer.WSUS.WSUSServer.IsSyncRunning()  $$<SMS_WSUS_CONFIGURATION_MANAGER><01-30-2014 14:13:12.462+00><thread=3840
    (0xF00)>
    Done using DEVSWAD\SWDTR-SRV-CMPATCH credentials~  $$<SMS_WSUS_CONFIGURATION_MANAGER><01-30-2014 14:13:12.478+00><thread=3840 (0xF00)>
    Failed to set Subscriptions on the WSUS
    . Error:(-2146233088)Unknown error 0x80131500~  $$<SMS_WSUS_CONFIGURATION_MANAGER><01-30-2014 14:13:12.478+00><thread=3840 (0xF00)>
    STATMSG: ID=6603 SEV=E LEV=M SOURCE="SMS Server" COMP="SMS_WSUS_CONFIGURATION_MANAGER" SYS=DCMPSTPV01.devswad.net SITE=SCW PID=2764 TID=3840 GMTDATE=Thu Jan 30 14:13:12.479 2014
    I have configured proper proxy account which can connect to microsoft website and the port i have configured in proxy to allow is
    80 and 443. I feel the port i need to allow may be i am not sure 8530 and 8531. Or 80 and 443 is fine. Please help
    Regards, Pratap

    It says to check WCM.log which i posted above
    wsync log:
    Sync failed: WSUS update source not found on site SCW. Please refer to WCM.log for configuration error details.. Source: getSiteUpdateSource  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 14:02:14.118+00><thread=4388 (0x1124)>
    STATMSG: ID=6703 SEV=E LEV=M SOURCE="SMS Server" COMP="SMS_WSUS_SYNC_MANAGER" SYS=DCMPSTPV01.devswad.net SITE=SCW PID=2764 TID=4388 GMTDATE=Fri Jan 31 14:02:14.119 2014 ISTR0="getSiteUpdateSource" ISTR1="WSUS update source not found on site SCW. Please
    refer to WCM.log for configuration error details." ISTR2="" ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=0  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 14:02:14.122+00><thread=4388 (0x1124)>
    Sync failed. Will retry in 60 minutes  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 14:02:14.122+00><thread=4388 (0x1124)>
    Setting sync alert to active state on site SCW  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 14:02:14.123+00><thread=4388 (0x1124)>
    Sync time: 0d00h00m00s  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 14:02:14.132+00><thread=4388 (0x1124)>
    Wakeup for a polling cycle  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 15:02:14.495+00><thread=4388 (0x1124)>
    Starting Sync  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 15:02:15.157+00><thread=4388 (0x1124)>
    Performing sync on retry schedule  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 15:02:15.163+00><thread=4388 (0x1124)>
    Read SUPs from SCF for DCMPSTPV01.devswad.net  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 15:02:15.577+00><thread=4388 (0x1124)>
    Found 1 SUPs  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 15:02:15.830+00><thread=4388 (0x1124)>
    Found active SUP DCMPSTPV01.devswad.net from SCF File.~  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 15:02:15.833+00><thread=4388 (0x1124)>
    Sync failed: WSUS update source not found on site SCW. Please refer to WCM.log for configuration error details.. Source: getSiteUpdateSource  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 15:02:15.876+00><thread=4388 (0x1124)>
    STATMSG: ID=6703 SEV=E LEV=M SOURCE="SMS Server" COMP="SMS_WSUS_SYNC_MANAGER" SYS=DCMPSTPV01.devswad.net SITE=SCW PID=2764 TID=4388 GMTDATE=Fri Jan 31 15:02:15.882 2014 ISTR0="getSiteUpdateSource" ISTR1="WSUS update source not found on site SCW. Please refer
    to WCM.log for configuration error details." ISTR2="" ISTR3="" ISTR4="" ISTR5="" ISTR6="" ISTR7="" ISTR8="" ISTR9="" NUMATTRS=0  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 15:02:15.892+00><thread=4388 (0x1124)>
    Sync failed. Will retry in 60 minutes  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 15:02:15.912+00><thread=4388 (0x1124)>
    Setting sync alert to active state on site SCW  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 15:02:15.915+00><thread=4388 (0x1124)>
    Sync time: 0d00h00m01s  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 15:02:17.024+00><thread=4388 (0x1124)>
    Next scheduled sync is a retry sync at 31/01/2014 16:02:15  $$<SMS_WSUS_SYNC_MANAGER><01-31-2014 15:02:17.151+00><thread=4388 (0x1124)>
    Regards, Pratap

  • SCCM 2012 SP1 CU4 migrated DP shows package status "unknown"

    I have a SCCM 2012 SP1 CU4 environment and have shared SCCM 2007 distribution points.
    Today I migrated one of the DP's which seems to work well.
    However all my packages shows now the status "unknown" for this migrated DP.
    This is a problem which should be fixed in CU4 according to the CU4 description. But it is not :-(
    Any idea how to solve this ? R2 install ?

    Some additional information:
    I noticed that the package sources are still available at the "old" ditribution point share abd not on the new sccm 2012 distribution point share. When performing actions described in step 3 below the package becomes available on the distribution point
    share......then i guess i can remove the content from the "old" distribution point share ????
    I noticed that when a package got the status "unknown" for de migrated DP the following action fix the problem:
    --> i remove the DP from the package and immediately add it again, the package status becomes "Successful".....hummm....ok....maybe a script could be created for this
    I noticed that when a package got the status "unknown" and the package is also located on the "distribution point share" then following will fix the issue:
    --> edit the package and remove the migrated DP and remove the checkbox for string on the distribution point share. Then add the DP again, click Apply and then set the checkbox for storing on the distribution point share and Apply again. Then wait and package
    will become available Successful and the package will become available on the distribution point share
    But i have 800 packages and 50 to be migrated DP's.....this is not a solution....but what is ????
    Any help, ideas, tips, hints, recommendations ?
    My overal thoughts are that migrating of a SCCM 2007 DP is not really working at all !!!!!
    Or does someone has other experience with e.g. R2 installed ? If so then I will upgrade first...

  • Error in push sccm client CcmSetup failed with error code 0x80070643 ccmsetup sccm 2012

    i want to push sccm client for all computer i enable automatic side-wide client installation 
     some computer get error code 0x80070643
    ccmsetup sccm 2012 this 
    when i tray manual installation get same error and ccmsetup.exe stopped 

    Duplicate of
    https://social.technet.microsoft.com/Forums/en-US/3bac4677-46b0-4d96-b63d-a819efcc7f35/error-in-push-sccm-client-ccmsetup-failed-with-error-code-0x80070643-ccmsetup-sccm-2012?forum=configmgrgeneral
    Please don't double post.
    Jason | http://blog.configmgrftw.com | @jasonsandys

  • Error installing SCCM 2012 SP1 client

    Hi All,
    I am getting the following error, detailed in the client.msi.log, when trying to install the SCCM 2012 SP1 client on a couple of windows 2008 R2 servers.
    Error 1904. Module C:\Windows\CCM\StatusAgentProxy.dll failed to register.  HRESULT -2147010895
    The ccmsetup.log details the same message without Error 1904 indicated.
    I am installing the client using the SUP method, which has worked without any problems on all 180 other windows servers I have done.  ccmsetup starts and downloads all pre reqs required for the client rollout, but it then hits this error and does not
    finish the installation.
    Any help would be much appreciated?
    Regards PowerShell90

    Hi,
    I've seen this issue a couple of times and usually it's related to incorrect Versions of C++ Library installed on the system you try to install the Client. Try and remove any existing installations, reboot and install this version;
    http://www.microsoft.com/en-us/download/details.aspx?id=26368
    Let me know how it goes.

  • It says it needs to be connected to itunes and restored.  when i do that, it goes through the whole process then comes up with "iphone could not be restored. unknown error code (-1)".  Please help

    My brother gave me his old iphone when the touch screen went out on mine.  It's in great shape but when I received it, it says that it needs to be connected to itunes to be restored.  I have done this and it goes through the whole process then says iphone "iphone" could not be restored.  unknown error code (-1).  There is not a -1 code on the list and I have tried most of the suggestions.
    Does my sim card need to be in when I am doing this?  And any other suggestions?

    I did put it in DFU mode but its still not working, although everytime it shows your iphone needs to be restored. Kindly help.