SCCM- software metering rules.

HI All,
Can some one share the information on how we can create software metering rule for Adobe in SCCM 2007?
Also, where can we find the correct file name or product name for the software to be metered?
Rgs,

Here are the Technet information and a step by step guide about software meetering:
http://technet.microsoft.com/en-us/library/bb633043.aspx
http://blogs.msdn.com/b/minfangl/archive/2011/04/29/step-by-step-on-how-to-use-software-metering.aspx

Similar Messages

  • Automatic creation software metering rules

    hi 
    I have installed SCCM 2012 r2 with two servers .A site server and a database server .I enabled software metering on client settings and software and hard ware inventory .But I ve got a problem that sccm doesn't create software metering rules automatically
    .I had already enabled Automatic create software metering rule on SMW properties . But no luck yet.
    when I create a rule manually It works fine but Its not working automatically . 

    you have configured 2% of computers must use the disabled programs to activate automatically (Specify
    the percentage of computers in the hierarchy that must use a program before a software metering rule is automatically created) .so pls check if any of the computers are using the disabled programs or not.Login to test computer and use the disabled
    program and then check the status.
    Eswar Koneti | Configmgr blog:
    www.eskonr.com | Linkedin: Eswar Koneti
    | Twitter: Eskonr
    I have more than 500 clients with enabled software metering .Dont you think it is enough to create rules automatically .?

  • Software Metering Rule not working SCCM 2012

    No usage data found to generate software metering report.
    mean that the
    machines ran meteriing, but there isnt nothing on the machiine that matches the
    meter rule so it says
    No usage data found to generate software metering
    report, int the SWMTRReportGen.log?
    Please help me in this issue.
    Regards,
    Faisal Alvi

    a common mistake is to configure a specific language and/or version that is not present on all machines.
    Kent Agerlund | My blogs: blog.coretech.dk and
    SCUG.DK | Twitter: @Agerlund | Linkedin:
    Kent Agerlund | Author:
    Mastering System Center 2012 R2 The Fundamentals

  • SCCM 2012 report/data for importing software metering rules..

    Hi, 
    I have a customer who would like to start using software metering. The plan is to create the rules manually, since I guess it would be overkill and/or have an huge performance impact to enable it for all...? We might be talking about 100-300 applications.
    To do it manually, a powershell script can be used for creating these based on a txt file containing the following information.
    Productname,  FileName,  OrginalFileName,  FileVersion
    The customer has then asked for a report/csv file showing these information for all .exe files, so they can pick what they want to have metered. The data amount will for sure be huge and unmanageable.
    Anyone has a good approach for this challenge? :-)
    Thanks in advance.
    Best regards
    Thomas

    The approach is to say NO, what they are asking for is huge in the range of 100,000 different exes, there is no way anyone will go the list. Instead, look at the build in report for count of installed software products and sort from largest count
    to smallest. Then create SWM rules for those applications that have a cost and not everyone has. Aka why would you crate a SWM rule for WORD or EXCEL? But it does make sense to create a rule for Visio or AutoCAD.
    Also why create a rule for two different version of Visio? Do you need it, why? Are you sure?
    Garth Jones | My blogs: Enhansoft and
    Old Blog site | Twitter:
    @GarthMJ

  • Software Metering Security Cannot Create Rule

    I recently created a role in SCCM 2012 using RBAViewer.exe granting yes to all permissions under the Software Metering Rule section. However, when a user with this rule assigned access the console, the ability to create a new rule is grayed out in the
    interface. Is there an additional permission that needs to be granted in order to make this happen?

    Hi,
    The problem should be the security scope. The user can create a new rule when I assign the "Default" security scope to an user or choose "All instances of the objects that are related to the assigned security roles"
    Best Regards,
    Joyce
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

  • SCCM 2012 Software Metering is not working

    SCCM 2012 Software Metering is not working in our environment. Other than software metering, reports work just fine.
    I have created a few simple software metering rules with “Acrobat.exe” and “Outlook.exe”. Rules are enabled. Rules were on at least 6 months.
    When I go to software metering reports, Month parameter value is empty and I can’t choose any value.
    I ran runmetersumm.exe on our server, it did not work as intended. :
    Summarizing data up to 0 hours old.
    File Usage Summary added -1 rows in 0 seconds.
    Monthly Usage Summary added -1 rows in 0 seconds.
    I am stumped. Why would it add minus rows?
    Any ideas how I can make software metering work on our environment?
    Thank you

    Finally figured it out.
    mtrmgr.log did not find any rules when I ran executables. So I knew it wasn't working on the server side.
    After searching for a while, I found the solution from the link below:
    http://social.technet.microsoft.com/Forums/en-US/8f048512-c357-437e-89ec-cee5356a10b1/software-metering-reports-empty?forum=configmanagergeneral
    1. Deleted RULECHG.RTA under policypv.box folder
    2. Removed and recreated metering rules again.
    Everything is working again now.
    Thank you.
    I do wonder how to avoid those problems going forward though.

  • SCCM 2012 Software Metering - Status Message ID

    Hi All,
    I am planning to
    configure “Automatic Software Uninstall”
    based on software metering rules as outlined in the following blogs.
    http://blogs.technet.com/b/neilp/archive/2012/11/27/software-metering-deep-dive-and-automation-part-1-use-it-or-lose-it-the-basics.aspx
    http://blogs.technet.com/b/neilp/archive/2012/11/29/software-metering-deep-dive-and-automation-part-2-use-it-or-lose-it-the-collections.aspx
    However, the account
    is currently installing software based on AD Software install groups.
    If a user does not
    use the software the software metering rule will ensure the machine is
    populated into the application uninstall collection. However, (problem) the
    machine account is still in the Install AD group and therefore, the uninstall
    will not occur, (as install deployment takes precedence over uninstall
    deployment)
    I could configure
    the install collection to exclude the uninstall collection, which would allow
    the software to uninstall. But, then once the machine automatically gets
    removed from the uninstall collection the software will install again as the
    machine is still in the AD group.
    Solution: Remove the machine account from the
    AD install Group.
    Question: What the best automated approach to
    remove the machine from AD install group. I am thinking along the lines of
    using Status Message ID’s based on the metering rule which causes a script to
    fire and remove the machine from the AD group.
    Would I have to
    create a status message Rule for each application? Or is it possible to create
    a generic one that can be leveraged for each application / metering rule
    combination?
    What Status Message ID should I use ?
    I would appreciate
    and comments or suggestions on the matter?
    Thanks
    Paul.

    Hello,
    You referred AD group, did you install this application via group policy?
    I think you can find out these machines via result of software metering. The following article show software metering rule:
    https://technet.microsoft.com/en-us/library/dd334612.aspx
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

  • Software Metering Report Wildly Inaccurate

    I've recently begun using the Software Metering feature in SCCM 2012, and when I pulled a certain report for my supervisor some of the information was incredibly inaccurate. Specifically, the "Total Usage of all Metered Software" report tells me
    that in the month of September we had 20,000+ users open Internet Explorer. However, if you click the software entry for Internet Explorer it reroutes you to the "Usage Trend Analysis" report that displays a much smaller number for that specific
    month - more like 600 users. Other software items have presumably correct entries that are identical in both the Total Usage and Usage Trend reports, but a handful of programs like IE, Chrome, and some Office products are showing up in the Total Usage with
    tens of thousands of users counted while another much more reasonable number is reported in the Usage Trend data.
    I've checked the Software Metering rules, and they're pretty bare bones - executable file name, neutral language or sometimes just English selected, and an asterisk for version numbers.  Nothing special, as far as I can tell.   Any thoughts
    on how this might be happening?

    Well this is interesting - I think the Total Usage for All Metered Software report must be completely screwed up on our system.  I can't tell what the query is searching for, but none of the data appears to be accurate except Terminal Services use. 
    For any software entry, if I click it and compare the "Users" column data from Total Usage for All Metered Software to Total Usage Trend Analysis, it's always off.  The query looks pretty straightforward, insofar as I understand things:
                declare @TimeKey int
                set @TimeKey=100*@Year+@Month
                select mr.ProductName as C018,
                IsNULL(UC.UCount,0) as C049,
                IsNULL(TSUC.TSUCount,0) as C050,
                IsNULL(UC.UCount,0)+IsNULL(TSUC.TSUCount,0) as C051,
                mr.SecurityKey
                from fn_rbac_MeteredProductRule(@UserSIDs) mr
                left join
                select SecurityKey, count(*) as TSUCount
                from
                (select distinct mf.SecurityKey, mus.ResourceID, mus.MeteredUserID
                from fn_rbac_MonthlyUsageSummary(@UserSIDs) mus
                join fn_rbac_MeteredFiles(@UserSIDs) mf on mus.FileID=mf.MeteredFileID
                where mus.TSUsageCount > 0 and
    mus.TimeKey=@TimeKey) as TSUsers
                group by SecurityKey
                ) as TSUC on mr.SecurityKey=TSUC.SecurityKey
                left join
                --select mf.SecurityKey, count(distinct ResourceID) as UCount
                select mf.SecurityKey, count(*) as UCount
                from fn_rbac_MonthlyUsageSummary(@UserSIDs) mus
                join fn_rbac_MeteredFiles(@UserSIDs) mf on mus.FileID=mf.MeteredFileID
                where
                -- mus.TSUsageCount = 0 and
                mus.UsageCount > 0
          and mus.TimeKey=@TimeKey
        group by mf.SecurityKey
    ) as UC on mr.SecurityKey=UC.SecurityKey
    order by mr.ProductName

  • Software Metering Properties greyed out

    Hello,
    I'm trying to configure automatic software metering rule generation, however, the Software Metering Properties button under Software Metering -> Home -> Settings is greyed out.  Software Metering is enabled in the Device Settings that are deployed.
    Please advise.
    Thank you.

    Hi BGeez37,
    Please try the following:
           Log in with the account that installed the primary site server. In the Administration workspace, select Security, Administrative Users and open
    the properties for the ConfigMgr Administrators group.
    Click Add, Security Scope and select "Only the instances of objects that are assigned to the specified security scopes and collections.
    Click OK
    Sratcli

  • Software Metering for SQL Server installations

    Hello everyone,
    I created a software metering rule for "sqlservr.exe" file. I was able to get information, but this information included SQL Express, which is something I don't need. 
    So, my question is, how do you guys meter the SQL Server 2xxx installations in your environment?
    Thanks!

    I may have done a poor job at explaining what kind of report/metering or inventory that I'm trying to get.
    Something like this:
    SERVER1 MS SQL Server 2008 R2
    SERVER2 MS SQL Server 2012
    SERVER3 MS SQL Server 2008 SP1
    SERVER4 MS SQL Server 2008 R2
    I thought I could achieve this kind of report using metering.

  • SCCM 2012 Reporting Capabilities for Software Metering

    Hi,
    I've been requested by my supervisors to get some information on metered software and computer usage in a specific lab, but I am unsure if I can obtain all the information they requested with just using SCCM. 
    I've already set up metering rules for the programs they want information on, software metering is enabled on the clients, and all of the lab computers are in in Configmgr and have good clients on them.  Here's the list of the requests:
    Total number of lab users by day
    Total hours logged into lab computers by day
    Total hours logged into a specific metered program by day
    Total hours running different internet browsers
    Total unique users over the course of a certain period of time
    I am a novice when it comes to reports in SCCM.  Are there built in reports that can give this information or would I have to write my own custom reports, or is this level of detail not possible for SCCM to give?
    Any advice would be appreciated.
    Thanks!

    The most requested information can be found in the obvious reports about
    Software Metering (\Monitoring\Overview\Reporting\Reports\Software Metering).
    My Blog: http://www.petervanderwoude.nl/
    Follow me on twitter: pvanderwoude

  • SCCM 2012 R2 - Software metering Reports Parameters Value not appear to choice

    Hello Every Body
    I hope to get answer as soon as possible
    I have SCCM 2012 R2 & SQL Server 2012 SP1, my problem is ( all software metering Reports Parameters Values Not appear so I cannot select
    Note:-
    ( All parameters Available Value set to Get Values From a Query) 

    Has it been over 45 days since you created the active SWM rules? Do all (most) other SWM reports
    work?
    all other reporting in SWM which doesn't ask for month and year working
    only the problem in year & Month Parameters Values
    note:-
    these reports doesn't need a 45 days to work, alwasy when i install SCCM reports working only from the second day of installation

  • Software Metering SCCM 2012 R2 - Firefox.exe

    We have software metering setup in SCCM 2012 R2 environment and it seems to be working well for most applications we have it configured for, with the exception of Mozilla Firefox. It's configured to monitor firefox.exe and for the version we are using
    the * so we get any version. We have Google Chrome setup the same way for chrome.exe and it works great. However when we run a report for Firefox there is no data. On a test system I have watched the mtrmgr.log and when I open Firefox, it says there are no
    matching rules. Am I missing something here, is there some trick to getting this to work for Firefox? Any insight is greatly appreciated. Thanks!

    Thanks for the quick reply. yes initially I had it set to "Any" for the language. I tried changing it to "English (United States)" to see if that would make a difference but it did not. I also tried browsing to "C:\Program
    Files (x86)\Mozilla Firefox\firefox.exe" and allowing the version to fill in automatically to 31.4.0 (rather than using the *) to see if that would make a difference but it also did not. Any ideas or suggestions? Thanks again!

  • Software metering date not available for selection sccm 2012

    Hi
    I have installed SCCM 2012. 
    While viewing a report for software metering date and year are not available for selection. they are blank. 

    thaks 
    I is showing after restart. 
    Now there is another problem. 
    When I see the software metering report for enabled rule i.e. KasperskyAdminKit I can not understand the figures
    Computers that have run a specific metered software program  
    NetBIOS Name
    Installed Site Code
    Last Usage
    Total Usages
    Average Usages per Day
    Total Duration (min)
    Average Duration of Use (min)
    Average Duration per Day (min)
    WIL-WNR-AV
    PUN
    11/16/2012 5:13:35 PM
    1
    0.03
    7384.27
    7384.27
    246.14
    How to know the the explanations for the underlined items ? 

  • Retrieve Software metering from SCCM 2007 Database using SQL Queries

    Good Morning All,
    Can anybody shed any light on querying the SQL DB for Software metering from SCCM using a machine name. I am basically looking for the table names etc?
    Thanks
    Craig

    Hi,
    They are documented here:
    http://technet.microsoft.com/en-us/library/dd334612.aspx
    Regards,
    Jörgen
    -- My System Center blog ccmexec.com -- Twitter
    @ccmexec