Schedule Cluster Validation Report

Is there a way to schedule a validation report to run once a day? We would also need to have Storage deselected in the test selection. Thanks.

Alexey provided you with references to use PowerShell.  Here is where you go to learn about the task scheduler -
http://technet.microsoft.com/en-us/library/cc721871.aspx  Or, if you want to use PowerShell for that part, too -
http://technet.microsoft.com/en-us/library/jj649816.aspx
Your question really is not related to Hyper-V, though.  Is there some other reason you posted in the Hyper-V forum?
. : | : . : | : . tim

Similar Messages

  • Failover Cluster Validation Report with warnings

    Hi,
    I have 2 Node cluster on windows 2008 R2.I have run cluster validation report and found following warnings pls suggest and guide me health of cluster and how to fix and remove these warnigns. thx.
    Validate All Drivers Signed
    Validate that tested servers contain only signed drivers.
    Validating that the servers contain only signed drivers...
    The node 'cluster1.domain.com'has unsigned drivers.
    Device Name  Device Class  Driver Version  Driver Date  Manufacturer  Inf Name  Driver Name  Device ID  Description  Status  Start Mode 
    Virtual CloneDrive  SCSIADAPTER  5.4.4.3  1/15/2011 12:00:00 AM  Elaborate Bytes AG  oem1.inf  Value Not Found  ROOT\SCSIADAPTER\0000  Virtual CloneDrive  Value Not Found  Unknown 
    Unsigned drivers were found on one or more of the servers.

    Hi,
    you need to run iso files at your cluster nodes often?
    Well i think you need to provide iso files to your VMs. This is possible without "Virtual CloneDrive"!
    I have seen many errors with this kind of software up to bluescreens.
    But ok if you really need this software just ignore the warning from cluster validation report.
    The cluster will work correctly if this are the only warnings from cluster validation report.
    Regards
    Sebastian

  • Failover Cluster Validation Report Error with IBM USB Remote NDIS Network device

    We are setting up Microsoft Windows Server 2008 R2 Failover Cluster on IBM X3850 X5 and get errors in the Failover cluster Validation Report due to the IBM USB Remote NDIS Network Device is using APIPA adresses and both servers are using same APIPA-adresse.
    How should I configure the Server and OS for the Failover cluster to be MS approved?
    IBM don't recommend that i disable the Network device, but it is a possible solution!?!

    What I did was use ipconfig /all to see the settings it is using and then when and set the ip setting on the NDIS driver to be that except I increment the last value by 1 for each node so that they do not have the same IP address.   I ran the
    cluster validation again and it came up clean and I have not experienced any issues yet.  It does give warnings about it being an Automatic Private IP Address and should not be used, which is ok because we are not going to use it anyways.
    Rich Baumet

  • Hyper-V cluster validation report "Found duplicate physical address" on nic team interfaces.

    I recently built a Windows 2012 Hyper-V cluster with 5 nodes. The validation report shows “duplicate physical address” error (error text pasted below).
    The hardware: HP BladeSystem – servers are BL460c blades, in a c7000 enclosure, connected to HP Virtual Connect switches.
    Each server has 2 physcal nics, teamed in Windows. In the NIC Teaming console, I created the following Team Interfaces and assigned each a VLAN ID:
    “Team1” (the default team)
    “Team1 - VLAN 204 – Management”
    “Team1 - VLAN 212 - 2012HB”
    “Team1 - VLAN 211 -Exchange DAG Replication”
    I also created 2 HV Virtual Switches. Neither one allows management interface to share. They are assigned to “Team1” and “Team1 - VLAN 211 -Exchange DAG Replication” respectively.
    Therefore, in Network Connection, I see the 2 physical Ethernet nics, and 4 “virtual” nics. Only 2 of them have IP addresses assigned: Management and HB. These are the two that the validation wizard complains
    about.
    The MAC address is not configurable in the NIC Teaming console, so I don’t see a way to resolve this error, except to use separate physical nics. I don’t want to do that because a) I would lose the benefits of
    the bandwidth aggregation that Virtual Connect provides, and b) When creating an Interface on a Team in Windows, it looks like it ALWAYS gives it the same MAC address, so that should be a supported configuration.
    Everything works just fine, and there are no other errors or IP conflicts or anything else. But I really want to fix it because I don’t know what unknown problems this may be causing.
    From the Cluster Validation report:
    Found duplicate physical address 10-60-4B-A9-4A-30 on node Cluster201.OurDomain.local adapter
    Team1 - VLAN 212 - 2012HB and node Cluster201.OurDomain.local adapter
    Team1 - VLAN 204 - Management.
    Found duplicate physical address F0-92-1C-13-3C-2C on node Cluster202.OurDomain.local adapter
    Team1 - VLAN 212 - 2012HB and node Cluster202.OurDomain.local adapter
    Team1 - VLAN 204 - Management.
    Found duplicate physical address 68-B5-99-C1-7E-9C on node Cluster210.OurDomain.local adapter
    Team1 - VLAN 212 - 2012HB and node Cluster210.OurDomain.local adapter
    Team1 - VLAN 204 - Management.
    Found duplicate physical address 3C-4A-92-DE-1E-74 on node Cluster211.OurDomain.local adapter VC-Team - VLAN 212 - 2012HB and node Cluster211.OurDomain.local adapter
    VC-Team - VLAN 204 - Management.
    Found duplicate physical address 68-B5-99-C0-3D-50 on node Cluster212.OurDomain.local adapter
    Team1 - VLAN 212 - 2012HB and node Cluster212.OurDomain.local adapter
    Team1 - VLAN 204 - Management.
    Thanks!
    Dan

    Hi Dan,
    "It turns out that both hosts had the same default MAC address ranges for their virtual switches. Since the host vNICs were attached to the virtual switch on each host they received the first couple of MAC addresses from the switches.
    For details please refer to following link:
    http://www.jefflafr.com/blog/4/19/2013/conflicting-mac-addresses-when-building-a-hyper-v-cluster-with-converged-networking
    Hope this helps
    Best Regards
    Elton Ji
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Access is denied messages in Win2012 R2 Failover Cluster validation report and CSV entering a paused state

    Been having some issues with nodes basically dropping out of clusters config.
    Error showing was
    "Cluster Shared Volume 'Volume1' ('Data') has entered a paused state because of '(c000020c)'. All I/O will temporarily be queued until a path to the volume is reestablished."
    All nodes (Poweredge 420) connected a Dell MD3200 shared SAS storage.
    Nodes point to Virtual 2012 R2 DC's
    Upon running validation with just two nodes, get the same errors over and over again.
    Bemused!
    List Software Updates
    Description: List software updates that have been applied on each node.
    An error occurred while executing the test.
    An error occurred while getting information about the software updates installed on the nodes.
    One or more errors occurred.
    Creating an instance of the COM component with CLSID {4142DD5D-3472-4370-8641-DE7856431FB0} from the IClassFactory failed due to the following error: 80070005 Access is denied. (Exception from HRESULT: 0x80070005 (E_ACCESSDENIED)).
    and
    List Disks
    Description: List all disks visible to one or more nodes. If a subset of disks is specified for validation, list only disks in the subset.
    An error occurred while executing the test.
    Storage cannot be validated at this time. Node 'zhyperv2.KISLNET.LOCAL' could not be initialized for validation testing. Possible causes for this are that another validation test is being run from another management client, or a previous validation test was
    unexpectedly terminated. If a previous validation test was unexpectedly terminated, the best corrective action is to restart the node and try again.
    Access is denied
    The event viewer on one of the hosts shows
    Cluster node 'zhyperv2' lost communication with cluster node 'zhyperv1'.  Network communication was reestablished. This could be due to communication temporarily being blocked by a firewall or connection security policy update. If the problem persists
    and network communication are not reestablished, the cluster service on one or more nodes will stop.  If that happens, run the Validate a Configuration wizard to check your network configuration. Additionally, check for hardware or software errors related
    to the network adapters on this node, and check for failures in any other network components to which the node is connected such as hubs, switches, or bridges.
    The Cluster service is shutting down because quorum was lost. This could be due to the loss of network connectivity between some or all nodes in the cluster, or a failover of the witness disk.
    Run the Validate a Configuration wizard to check your network configuration. If the condition persists, check for hardware or software errors related to the network adapter. Also check for failures in any other network components to which the node is connected
    such as hubs, switches, or bridges.
    Only other warning is because the 4 nic ports in each node server are teamed on one ip address split over two switches - I am not concernd about this and could if required split then pairs, I think this is a red herring????

    Hi,
    Such events happen because of the following reason:
    1- Client for Microsoft Networks and File and Printer Sharing for Microsoft Networks not enabled on all network interfaces. Check this KB article: http://support.microsoft.com/kb/2008795
    . Please make sure these two protocols are enabled on all cluster networks
    2- Network connectivity issue can cause this event as well. Please make sure the network cabling/Cards/Switches are correctly configured and working as expected
    3- Connectivity issue with the storage can also cause this event. Please make sure all the nodes are connected to storage. Check HBA/Cabling connectivity to SAN. Make sure
    that the SAN drivers are up-to-date.
    4- Antivirus may interrupt network communication and cause this failure. Please exclude CSV volumes from being scanned by AV: http://social.technet.microsoft.com/wiki/contents/articles/953.microsoft-anti-virus-exclusion-list.aspx
    5- Disable TCP Chimney related settings on all cluster nodes. http://support.microsoft.com/kb/951037
    6- Please check the Network Binding Order (http://social.technet.microsoft.com/Forums/windowsserver/en-US/2535c73a-a347-4152-be7a-ea7b24159520/hyperv-r2-csv-cluster-recommended-binding-order?forum=windowsserver2008r2highavailability)
    7- Firewall Rules For All Inbound and Outbound For Cluster and Hyper-V for all the Profiles
    8- Update NIC Driver/Firmware.
    9- Check Compatibility of the NIC with Windows Server 2012R2
    10- Set-NetAdapterRss - Resources and Tools for IT Professionals | TechNet : http://technet.microsoft.com/en-us/library/jj130863.aspx
    11- Check the Following Article http://social.technet.microsoft.com/Forums/windowsserver/en-US/e06fede9-931c-4dee-8379-4fd985e20f0a/hypervvmswitch-eventid-106
    12- General Updates to be applied on the nodes :
    Windows RT 8.1, Windows 8.1, and Windows Server 2012 R2 update rollup: November 2013 : http://support.microsoft.com/kb/2887595
    Windows 8.1 and Windows Server 2012 R2 General Availability Update Rollup :
    http://support.microsoft.com/kb/2883200
    Hope this helps.
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Validation Report warnings

    In my application, I have 3 processes, and a PDF form,
    the 3 processes reference the PDF form,
    so each time I make a change to the PDF form, I got 3 warnings in the Validation Report tab, saying that the PDF that these processes depend on has been changed.
    I can get rid of those warnings manually by doing the "Validate" on those processes.
    my question is, why it doesn't do the Validate automatically? and stop displaying those warnings all the time?
    is there a way to let it do the Validate automatically?
    thanks

    Hi,
    you need to run iso files at your cluster nodes often?
    Well i think you need to provide iso files to your VMs. This is possible without "Virtual CloneDrive"!
    I have seen many errors with this kind of software up to bluescreens.
    But ok if you really need this software just ignore the warning from cluster validation report.
    The cluster will work correctly if this are the only warnings from cluster validation report.
    Regards
    Sebastian

  • Getting error while schedule a webi report

    Hi All,
    I am getting error "A database error occured. The database error text is: The supplied XML is not valid. [Measures].[4KO5AOUTL3ZKE55WDDOMUB0AI]. (WIS 10901) " while scheduling a Webi report.
    Could anyone help me regarding the error?
    Regards

    Hi Manoj,
    Go to the controls tab in parameters in universe designer and there increase the "Limit size of result set to" and "limit execution time to".
    Also in webi go to the edit query and increase the "maximum rows retrived" and "maximu retrievel time".
    I think this should avoid partial results.
    Thanks,
    Neeraj

  • BPC 7.0MS Validation Report isn't displayed

    Hello colleage,
    This question is related to the following thread.
    [BPC - Submitted data did not pass validation|Re: BPC - Submitted data did not pass validation;
    <Procedure>
    -eSubmit > Validate submission
    -The message is displayed:
    "Submitted data did not pass validation; you may need to resubmit it.
    A Validation report cannot be generated because there is no Validation report template."
    I think that Validation report can be opened on this timing.
    Are there missing settings?
    If you have any information or ideas, could you please help me?
    <Setting>
    Application Parameter
    LOCKREPORT: Validate.xlt
    Validation Report
    eExcel\Input Schedules\Wizard\Validate.xlt
    Thank you in advance.
    Best regards,
    Kei Ogino
    Edited by: Kei Ogino on Jun 24, 2009 11:00 AM

    Hi Ki Ogino,
    We have tested the behaviour for the same scenario.
    You get this error, if the template is opened from the /INPUT SCHEDULE/WIZARD or the template not accessible from the relevant location.
    Otherwise, able to succesfully validate the data submission by both ways:
    1. eSubmit :: Validate Submission
    2. Send Data :: Validate Submission before sending.
    The issue noticed is that data not refreshed / displayed in the input template after succesful sending into BPC database, whereas the same data can be viewed by new template or ANYBYANY report.
    Setting -- APPLICATION PARAMETER for LOCKREPORT.
    The report launches when submission validation for a data region is not u20180u2019 in BPC Excel. The template should be located in the eExcel\Report\ folder., though it is currently available in the path eExcel\Input Schedules\Wizard\Validate.xlt.
    Try this.
    Cheers
    Uma

  • Windows Server 2012 Cluster Validation Failing On List All Potential Cluster Disks

    I'm in the process of setting up a new cluster using Windows Server 2012 with a view to migrate from our existing 2008 R2 cluster.  I am having problems validating the storage and the wizard keeps failing on the List All Potential Cluster Disks
    test (which causes all the other storage tests to be cancelled).
    I'm getting the following error:
    Failed while verifying removal of any Persistent Reservation on physical disk 19ba99a4 at node RC-HYPERV-3.riddlesdown.local.
    When I look in validation report, disk 19ba99a4 is the management LUN (Access LUN 31 as termed by the storage software).
    Looking on my 2008 R2 cluster this doesn't appear in Disk Management.
    Any ideas how I can get rid of it or the error that it is causing?
     

    Hi,
    Thank you for your question.
    I am trying to involve someone familiar with this topic to further look at this issue. There might be some time delay. Appreciate your patience.
    Thank you for your understanding and support.
    Best Regards,
    Aiden
    TechNet Subscriber Support
    If you are
    TechNet Subscription
    user and have any feedback on our support quality, please send your feedback
    here.
    Aiden Cao
    TechNet Community Support

  • Cluster Validation error.

    I have 2012 R2 Failover cluster with two nodes.
    When I try to add third node and run Validation test, I've got error in Validation Report:
    "Two disks have been found on node Hyperv01.local.com with duplicate disk signatures or disk GUIDs. The disks involved are physical disk 2 and physical disk 12. There may be a Multipath I/O (MPIO) problem such as the software is not installed or is not
    working properly. If MPIO is not involved, or MPIO has been verified as working, you must either mask one of these disks off at this node, or run validation and specify a disk list that includes only one of these disks, for example by using the Test-Cluster
    cmdlet in Windows PowerShell."
    But disk signature and disk GUIDs are different.
    All disks connected via ISCSI.
    Can anyone please help?
    Thank you.

    Hi oxyGEN_ua,
    Please confirm your storage compatible with server 2012r2 and your do not use the disk which marked as active and please confirm all your node have the same update and hotfix,
    please install the following update.
    Recommended hotfixes and updates for Windows Server 2012 R2-based failover clusters
    https://support.microsoft.com/kb/2920151/en-us?wa=wsignin1.0
    I’m glad to be of help to you!
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • How to create a event at the time of scheduling a webi report

    if event fires then only it schedules the webi report
    give in a brief steps
    pls its urgent for me.

    Refer to the below blog
    http://scn.sap.com/community/bi-platform/blog/2013/01/07/cmcevents-in-business-objects-and-its-usage
    Thanks,
    Prithvi

  • Schedule a Webi report

    Hi All,
    I am getting error "A database error occured. The database error text is: Failed to execute MDX query. Reason: Inconsistent input parameter (parameter: <unknown>, value <unknown>). (WIS 10901)  " while scheduling a Webi report.
    Could anyone help me regards the error?
    Regards

    This error message means the parameter assigned to the prompt of the report while scheduling, was not correct.
    Please check the parameters in the prompt section while scheduling and assign proper values.

  • SharePoint 2010: Scheduled Web Analytics Reports workflow is not sending ANY email

    Hello,
    I've a SharePoint 2010 Enterprise farm. I setup a Scheduled Web Analytics Reports workflow in a site collection with different web analytics reports options checked. So far I've not got ANY email. When I went to Site Workflows, I'm seeing that the workflow
    is running. When I click on Completed status, I see below outcome in the Workflow History section:
    "Email sent but reports with no data were not attached."
    And I see below information in the Workflow History list:
    "Attached are the daily Web Analytics reports for 1/7/2015 through 1/7/2015 for SharePoint Site Collection
    http://server/team/site scheduled by workflow "SharePoint Site Web Analytics Reports". "
    I am able to generate the reports manually by going to Site Collection Web Analytics Reports, but I want to schedule them. The problem is I'm not getting ANY email in my inbox. What am I missing here? Are the emails getting filtered by Outlook or workflow
    is not sending emails at all?
    Please help! This is getting frustrated.
    Thanks,
    Ashish

    Hi Ashish,
    Based on your description, my understanding is that the email is not sent from the Scheduled Web Analytics Reports workflow.
    I recommend to the things below:
    1. Check if the Outgoing email has been configured for the web application where you run the Scheduled Web Analytics Reports workflow.
    In Central Administration > Application management > Manage web applications > select the corresponding web application > click General Settings in the ribbon and select Outgoing E-mail.
    2. Make sure that your account has email address configured.
    Thanks,
    Victoria
    Forum Support
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact
    [email protected]
    Victoria Xia
    TechNet Community Support

  • Schedule a Webi report from the CMC

    Hi, ALL
    Is there a way to schedule a Webi report from the CMC without using an email account in the
    'from' box? There are other placeholders that can be used but I don't know how
    to use them please advise.
    Thanks.

    Hermant,
          You need to make sure you configure the proper email server.   Go to the CMC - Server > AdaptiveJobServer>Destination>Email.  You may need to enable Email as one of the Destinations.
    You must configure all the HIGHLIGHTED options.
    Regards,
    Ajay

  • CRVS2010 Beta - Error: No valid Report Source is available

    I am new to using crystal reports in .NET so any (un-jargoned) help is much welcomed and appreciated.
    I am implementing an web application on a Windows XP machine using VS2010 and have downloaded and installed the CR4VS2010 beta 2 and the CRforNET40_x86.  All installed OK with no errors.
    I have embedded a crystal report viewer into my web page and have populated a dataset (myDS) successfully from my SQL server connection earlier in the code.
    The report (stoppages.rpt) is an untyped report stored in a separate folder and has 2 datetime parameters to pass in.  When I run the web app it runs fine until the parameter boxes appear - I enter 2 valid date values into the parameter boxes when I hit OK I get an error - No valid report source is available.
    My code is shown below - I have searched other forums and it was suggested to put in the session.add part but the error occurs with or without this bit in...
    Please help - newbie and desparate! Thanks
    Dim myReportDocument = New CrystalDecisions.CrystalReports.Engine.ReportDocument()
                myReportDocument.Load("C:\Reports\stoppages.rpt")
                myReportDocument.SetDataSource(myDS)
                Session.Add("Report", myReportDocument)
                crvThisReport.ReportSource = myReportDocument
    Subject modified as per the sticky post at the top of this forum; [Crystal Reports for Visual Studio 2010 Beta - read before posting|Crystal Reports for Visual Studio 2010 Beta - read before posting;
    Edited by: Ludek Uher on Oct 13, 2010 7:22 AM

    Hi Ludek,  I tried adding
    <startup useLegacyV2RuntimeActivationPolicy="true">
      <supportedRuntime version="v4.0"/>
    </startup>
    to the config file but it didnt resolve the problems. 
    However I think I have found a work-around solution to setting the parameters programmatically rather than use the crystal report viewer pop-up boxes.  I am posting my code to help anyone else who might be experiencing the same problems:
    Dim myReportDocument = New CrystalDecisions.CrystalReports.Engine.ReportDocument()
    myReportDocument.Load(Server.MapPath(strRptPath))
    myDS.WriteXml(Server.MapPath(strXMLPath), XmlWriteMode.WriteSchema)
    myReportDocument.SetDataSource(myDS)
    myReportDocument.Refresh()
    myReportDocument.SetParameterValue("DateFrom", #9/1/2010 6:35:00 AM#)
    myReportDocument.SetParameterValue("DateTo", #9/8/2010 6:35:00 PM#)
    crvThisReport.ReportSource = myReportDocument
    DateFrom and DateTo are the parameter names within my crystal report.
    It seems to be working fine, it stops the crystal report viewer from displaying the parameter pop-up box which stops the error occurring.  However, the error still occurs when you want to interact with the report in other ways, ie page navigation, group tree navigation.  It still allows me to print, export and zoom in and out, so I will have to disable some buttons and features until this error is resolved - the search continues!
    Thanks for all your help and advise.
    Edited by: juliep68 on Oct 14, 2010 11:33 PM

Maybe you are looking for

  • Safari hasn't worked for two weeks....Could I please get some insight/advice?

    For the past two weeks I haven't been able to get Safari to run on my iMAC...it's a 2012 version.  The only thing i've done lately is install a 3TB time machine and I use a 2013 airport express *** a range extender for that. I am totally confused at

  • How to connect two i phone 4 g to one itunes on one pc ?

    Am new to i phone, have a pc (WINDOWS xp) which has i tunes downloaded and synced with one i phone , how can i use the same pc for my new i phone. Please guide. Don't want to create any issues with the existing i phone that has been using the itunes

  • Can you run multiple ATV's?

    Are there any issues with running multiple ATV's at the same time- playing different content? Also, are you able to broadcast the same content (say from itunes on my Mac) to all ATV's at once (I can see this used at parties where I can have all the T

  • Email Address (SMTP-ADDR) in Employee Vendor Creation through PRAA

    Hi All, We have a requirement tp update Vendor Email Address (SMTP-ADDR) from HR master Data (Infotype 0105). I have checked the Available BADI "BADI_EXITS_RPRAPA00" but nothing helpful. Can you please suggest on the same ? Thanks and Regards, -Pooja

  • Attachment getInputStream does not work with REMOTE_CLIENT

    Hi. So, I am working with Worklist attachments. When using the WorkflowServiceClientFactory.REMOTE_CLIENT I can grab the task just fine. However, when using the getInputStream on the task attachment, I get a null input stream. The same cannot be said