Hello,
We have a boxi 3.1 installation here and i am trying to get the scheduling and sending to inbox to work. I have no problem when i am logged in as the administartor.
Now as a user, when i schedule a report and looking for recipients, i can see all users. ( At Users and Groups in CMC Everyone is set with view objects rights)
However the schedule fails and i get the following error
"recipient error user01 CrystalEnterprise.Managed"
Can you please advise what we are missing here?
Edited by: ramaks on May 26, 2009 4:00 PM

Hi,
we had the same problem. In our case there was a rigth missing. Log in to the CMC and go to the "inbox". Check whether the right "Add objects to the folder" is set for All users on the highest level ("Manage Top Level Security/All Inboxes").
Regards
Kerstin

Similar Messages

  • Scheduled WEBI reports based on File Events not retrieving data

    Dear All,
    We are facing performance related issues with Scheduled WEBI reports based on file based events.
    When running Web Intelligence on demand it takes  4to 5 Minutes.
    Scheduling the same report in Excel format it takes more than 20 minutes.Schedule status showing success but no data found in Excel instance.
    Env:BOXI3.1 Sp3
    Windows 2003
    It woud be great if any one can share your ideas.
    Thanks,
    Kumar

    Hi Kumar,
    Is your report has prompts?
    if you have prompts , make sure that you assigned prompts in the schedule also.
    Hope you have multiple webi processing servers and adpative job servers for better scheduling performance.
    Try below solution .
    On the BusinessObjects Enterprise server, navigate to the folder <install root>\Business Objects\BusinessObjects Enterprise 12.0\win32_X86\dataAccess\connectionServer
    Open the file cs.config in a text editor such as Notepad
    Search the file contents for the string "Traces Active"
    Modify the line from  <Traces Active="Yes">   to  <Traces Active="No">
    Save the cs.config file
    Restart the Web Intelligence Processing Server

  • Error when scheduling WEBI report to FTP server

    Hi
    We are getting error "destination directory error. CrystalEnterprise.Ftp: 550 Requested action not taken" while scheduling WEBI report to FTP server.
    Any help would be appreciated
    Regards,
    Anisa

    Hi All,
    I want a run my report once by scheduling, so i provide a time interval for scheduling a report
    start date/ time : 11:38:AM 10/30/2011
    end date/time : 11:43:AM 10/30/2011
    after completion of end time....report is failed and fetching an error
    Error : Object could not be scheduled within the specified time Interval
    Any solution for resolving this error

  • SharePoint 2010: Scheduled Web Analytics Reports workflow is not sending ANY email

    Hello,
    I've a SharePoint 2010 Enterprise farm. I setup a Scheduled Web Analytics Reports workflow in a site collection with different web analytics reports options checked. So far I've not got ANY email. When I went to Site Workflows, I'm seeing that the workflow
    is running. When I click on Completed status, I see below outcome in the Workflow History section:
    "Email sent but reports with no data were not attached."
    And I see below information in the Workflow History list:
    "Attached are the daily Web Analytics reports for 1/7/2015 through 1/7/2015 for SharePoint Site Collection
    http://server/team/site scheduled by workflow "SharePoint Site Web Analytics Reports". "
    I am able to generate the reports manually by going to Site Collection Web Analytics Reports, but I want to schedule them. The problem is I'm not getting ANY email in my inbox. What am I missing here? Are the emails getting filtered by Outlook or workflow
    is not sending emails at all?
    Please help! This is getting frustrated.
    Thanks,
    Ashish

    Hi Ashish,
    Based on your description, my understanding is that the email is not sent from the Scheduled Web Analytics Reports workflow.
    I recommend to the things below:
    1. Check if the Outgoing email has been configured for the web application where you run the Scheduled Web Analytics Reports workflow.
    In Central Administration > Application management > Manage web applications > select the corresponding web application > click General Settings in the ribbon and select Outgoing E-mail.
    2. Make sure that your account has email address configured.
    Thanks,
    Victoria
    Forum Support
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact
    [email protected]
    Victoria Xia
    TechNet Community Support

  • BO 4.0 Schedule Webi  - Class not found Error

    Hello,
    We are using SDK concerning scheduling Webi-Reports to PDF-format.
    Operating System: Linux
    Business Objects 4.0 (SBOP BI Platform 4.0 SP02 Patch 6 )
    We have developed Java - Program using BO SDK.
    We are using ECLIPSE for development.
    Regarding SDK Libaries we copied all libs from BO 4.0 - system (Unix Directory <businessobjects_root>/java/libe) to client for ECLIPSE.
    Our program should schedule a Webi - Report to PDF format.
    Java Coding is compiled without any errors, all required BO-SDK-Libs are included in source-code.
    Already previously we were able to schedule a crystal report via Java program.
    Unfortunately there are errors concerning scheduling Webi reports.
    We published java-program to BO-server.
    In properties of java-program we inserted name of class.
    After running the java programm this error appears:
    Exception in thread "main" java.lang.NoClassDefFoundError: com/businessobjects/sdk/plugin/desktop/webi/IWebi
         at CargoClass02.scheduleReport(CargoClass02.java:23)
         at CargoClass02.run(CargoClass02.java:14)
         at com.crystaldecisions.sdk.plugin.desktop.program.internal.ProgramWrapper.main(ProgramWrapper.java:174)
    Caused by: java.lang.ClassNotFoundException: com.businessobjects.sdk.plugin.desktop.webi.IWebi
         at java.net.URLClassLoader$1.run(URLClassLoader.java:261)
         at java.security.AccessController.doPrivileged(Native Method)
         at java.net.URLClassLoader.findClass(URLClassLoader.java:249)
         at java.lang.ClassLoader.loadClass(ClassLoader.java:354)
         at sun.misc.Launcher$AppClassLoader.loadClass(Launcher.java:344)
         at java.lang.ClassLoader.loadClass(ClassLoader.java:299)
         at java.lang.ClassLoader.loadClassInternal(ClassLoader.java:367)
    Kind regards,
    Fritz Korntner

    Hello Fritz,
    Sorry - I completely neglected the important bit in your exception trace.
    What you have is a Java Program Object.
    The Program Object is being loaded by the Program Job Server child process, but the classloader is complaining about not finding needed InfoObject classes.
    What's at issue is that, unlike for XI 3.x and previous, the default classloader classpath do not have the BusinessObjects Enterprise Java SDK libraries pre-defined.  You need to define it when publishing the Program Object.
    I don't think what Terry mentions would apply to your situation, since that issue should be caught during compile time with the 4.0 libs.
    Sincerely,
    Ted Ueda

  • Scheduling web intelligence reports from SAP EP Portal : Server Side Trust

    Hello,
    We have set-up SSO between SAP EP 701, SAP BI 701 and Business Object XI 3.1  to allow users to access reports without having to sign-on again as explained here :
    /people/ingo.hilgefort/blog/2008/09/19/businessobjects-and-sap--configure-sap-authentication
    But, we have recently been contacted by some users because when scheduling Webi Report from a link within the portal they have the following errors :
    u201CA database error occured. The database error text is: Unable to connect to SAP BW server System received an expired SSO ticket. (WIS 10901) u201D
    The user told us that he doesn't encounter the error when :
    Login in directly to the BO Infoview (without SSO from the SAP Enterprise Portal.)
    The first Webi scheduling is succesful from the portal (I suppose because the portal token is still valid)
    I understand that we also have to configure the Server Side Trust between BO Enterprise server and the SAP BI7 backend as explained here , but I do not really understand its purpose
    https://websmp106.sap-ag.de/~sapidb/011000358700001646962008E/XI3-1_BIP_SAP_INSTALL_EN.pdf
    I've found a similar discussions here ;
    Issue with SAP Single Sign-On and Scheduling Reports
    I still have some questions :
    If we configure the Server Side Trust between BO Enterprise server and the SAP BI7 backend .
    The Portal Logon ticket will remain an issue at some point of time , does it mean tha the WeBi report job sheduling should not be perfromed from the SAP EP Portal ?
    We haven't configured the Server Side Trust , yet the users told us that they are able to schedule webi report directly from the BO Infoview ? How is it posible ?
    Thank you in advance for your help.
    Regards.

    Thank you Mr Hilgefort for your detailled explanations.
    I now have to provide some explanations to my managers, and to be honest , there are still some points that
    are unclear to me, and it would be extremely helpful if could confirm (or not) the follwoing points.
    When scheduing Webi report from the sap portal, we're getting SSO errors.
    SAP provide the follwoing note explaining how to extend the validity of the J2EE token (Portal token), but this is not a long term solution, at certain point of time the ticket will expire. Webi shceduling should not be perfromed from the Portal.
    Sap note 1352127 - Scheduled Webi report fails with: A database error occurred. The database error text is: Unable to connect to SAP BW server System received an expired SSO ticket
    Webi Scheduling should be performed from BO Infoview. SNC should be configured between BO server and SAP BI7.0 backend.
    We should Configure Server SNC as explained in the BusinessObjects XI Integration for SAP Solutions Installation and Administration Guide at Chapter "Configuring SAP for server-side trust". (1341043)
    The SAP Portal is not involved here and is not an option even with the configuration of SNC/Server side trust.
    thank you for your patience.
    Best Regards.

  • Scheduling webi reports via Java SDK in BI 4.1

    Hi,
    Has anyone been able to schedule a Webi report containing date prompts via Java SDK in BI 4.1? I have tried doing so but it doesn't work when date prompts are involved, I get the exception raised: java.lang.NullPointerException error. Though the scheduled instance is created and the date prompt appears to be correctly populated the report fails with the above mentioned error message. The code is working for other text prompts but fails when I have a date prompt in the report. I am using the populateWebiPrompts() method to populate the prompts.
    CF

    Hi Christopher,
    Try adding the following line in your code before scheduling:
    iWebi.setUserInputLocaleName(documentInstance.getProperties().getProperty(PropertiesType.BASE_LOCALE));
    Also as an FYI, please refer below details.
    For scheduling webi reports with prompts, the only supported way is to use Restful webservices SDKs.
    The feature of scheduling a webi report with prompts were deprected from release BI 4.x and introduced in the new restfull webservices. Restful is the future which SAP is focussing and would be great to have your application on supported terms with SAP.
    You can get details about the restful webservices from the documents and blogs available at below forum
    http://scn.sap.com/community/restful-sdk
    Thanks,
    Prithvi

  • Scheduling webi report

    Hi,
    When i schedule webi report as "Now", it takes some time to start? The status is in "Pending" state fo long time.
    Could you please let me know
    What is the reason behind this? How this can be resolved?
    Thanks & Regards,
    M.A.Jilani

    Hi Khaled,
    Normally when we schedule a report as "Now"..it takes hardly 1 min to start..
    in my case it is taking more than half an hr or more to start...
    Status     Success
    External Destination:     None
    Creation Time:     7/26/2010 5:45 AM
    Start Time:     7/26/2010 6:12 AM
    End Time:     7/26/2010 6:14 AM

  • Date error when scheduling webi reports

    Hi,
    When i click the prompt option in re schedule the scheduled webi report, i got the error "while trying to invoke the method java.util.date.gettime() of a null object loaded from a local variable 'date' "
    The BI version is 4.1 SP03
    The scheduled webi reports failing and got the error as "Unparseable date: "01/01/1900" "
    How to solve this issues?
    Regards,
    Kathir

    This might fix it from the note http://service.sap.com/sap/support/notes/1981477
    Create a WebI report that uses a date object in the Query Filters
    Schedule the report
    Reschedule by manually entering date value which shows only date and no timestampExample: 12/31/2007
    Reschedule by selecting date value from the calendar which shows date timestampExample: 12/31/2007 12:00:00 AM
    Create a biar file using the Import Wizard and migrate to BI 4.1 SP2
    BI 4.1 SP2 BILaunchPad, navigate to and Right click the report and go to “History”
    Right click the instance without a timestamp for the date parameter and select “Reschedule”
    Click on “Prompts” on the left menu and note an error is produced:This error occurred: while trying to invoke the method java.util.Date.getTime() of an object loaded from local variable ‘date’
    Attempting to schedule this instance (as Run Now or Reschedule) without selecting a Prompt value fails with the error:  Unparseable date: “12/31/2007”
    Using the instance with a timestamp works as expected

  • Error When Trying to Schedule Webi report using SAP authentication

    Hii,
    We are trying to Schedule Webi report in CMC for Group of Users using SAP authentication(SSO) ,While Trying this we are geting error Unable to Connect to SAP BW server Incomplete Logon Data ..(IES 10901) .
    Authorization done at BI side and Its working properly.Users are able to login into BI Launchpad and View Report as per authorization
    Some Webi reports are created using BICS connection and some  are created using Universe Design Tool (.UNV) which are migrated from BO 3.1 to BO 4.0
    Server Status:
    BO server and Client Tools-:BO 4.0 SP6
    BW System-7.01
    Please refer attach Screen Shot

    Hi Rupesh,
    Please check the below note:
    Seems issue with SNC/STS settings.
    1798197 - Schedules fails with error "Database error: Unable to connect to SAP BW server Incomplete logon data.. (IES 10901)" in BI 4.0
    https://websmp130.sap-ag.de/sap(bD1lbiZjPTAwMQ==)/bc/bsp/sno/ui_entry/entry.htm?param=69765F6D6F64653D3030312669765F7361…

  • Getting multiple error while refreshing or scheduling WebI report

    Hi BO Admin Experts ,
    Feacing  multiple errors  while refreshing or scheduling webi reports in BI4.0 CMC ,
    Please find the below errors :
    1)report schedule status failed
    2)Parameters : xxxcorp-franklinee; ATOu supply unv
    Error Message : An internal error occured while calling 'ProcessDPcmndsEx' API (Error:ERR_WIS_30270)
    3 ) Format : WebI
    Parameters : 10000000000159270
    Error Message :CORBA error while communicating with the SL service
    Could you please help me on the abive 3 issues for the WebI schedule reports
    Cheers ,
    Pradeep Gorpadu

    Hi,
    While refreshing the WEBI Reports would recommend you check the WEBI PROCESSING Server's last changed date from CMC--> Servers.
    Check when you are refreshing the reports, do you see the time stamp changed of WEBI PROCESSING servers?
    Do you keep getting this error messages for all WEBI reports? Can you re-produce this with simple e-fashion reports as well?
    After that go to the node where WEBI PROCESSING servers installed and check on the event viewer details if you see any relevant error messages.
    Regards,
    Upendra

  • Scheduled Webi Reports Don't Open on iOS's MS Exchange Mail

    Hi all,
    I am not sure if this is the right place to write this post but I will try anyway.
    We are using BO 4.0 SP6 and schedule webi reports as attached xlsx of pdf in e-mails.The problem is that the attached pdf's and excel files don't open right away in iPhone's native mail application when using MS Exchange. A tiny question mark shows up on the top corner of the attachment and when you tap on it, it asks which application to use to open it. We can choose iBooks app for example to view the file. We would like the attachment to open right away as we tap on it as it does usually.
    Here are some test results:
    -We have observed this issue on iOS 8. However, there are rumors that it started with iOS 7. Same rumors suggest that it would work fine before iOS 7.
    -We use iOS' native mail application with a MS Exchange account set up.
    -We have also tested it with a gmail account set up next to the exchange account. The attachment opened with no problem.
    -If someone forwards the mail received from the BO server, to another exchange mail, the attachment opens just fine.
    -We have no problem opening other exchange mails with attachments on mobile.
    We suspect, the exchange mail can't confirm the sender address thus can't trust the attachment if it is really a pdf-excel file. So we tried scheduling the webi report with a valid mail address in the sender information box but it didn't work.
    Has anyone came across such a problem?
    I know this issue involve SAP, Apple and Microsoft and each one will point the other for the blame. But any help will be appreciated.
    Thank you

    Hi Emre,
    Though this appears on Mobile, this belongs to Webi Product team. As the schedule of Webi reports and the email output would be controlled by them. They can work with Apple to identify the cause and fix the defect. Hence, you can post your question in SAP BusinessObjects Web Intelligence
    I would also recommend that you contact Webi Product Support through the official channel http://support.sap.com/incident
    Regards,
    Ashutosh

  • Scheduling Webi reports from SAP Portal.

    is there a way to schedule webi reports from the SAP enterpirse portal.
    Toor.

    Hello Ingo,
    We also need to implement the server side trust configuration.
    I'm searching the document you are refering to but couldn't find it :
    I only found the fowllowing documents which doesn't discuss the server side trust
    BusinessObjects XI Integration Kit for SAP Installation Guide
    BusinessObjects XI Integration for SAP Solutions User's Guide
    Business Objects XI Integration Kit for SAP Release Notes
    I didn't found it there http://help.sap.com/businessobject/product_guides/boexi/en/boxi_DocMap_en.pdf
    Could you provide me the direct link please ?
    Thank you !
    Edited by: Raoul Shiro on Apr 1, 2011 10:05 AM

  • Xi 3.1 SP3 giving java null pointer exception error on scheduling webi

    after we have the system uptime running for a few days and have schedule webi jobs successfully for a few days, we constant get the message java null pointer exception error on scheduling webi.
    This only have days after restarting the environment.
    Seems to be coming up after scheduling a certain amount of webi reports.
    Only doing a stop all services and restart resolves the issue.
    XI 3.1 SP3
    SAP IK Sp3
    Tomcat55
    HPUX-IA64 (Hpunix) platform.

    Hello, I have the same issue.  If someone gives you an answer please let me know how to fix it.

  • App server , process scheduler , web server and DB scripts

    Team,
    Good Morning.
    I am looking for the script which will help me in doing health check-up for app server , process scheduler , web server and DB.
    The script should trigger a email when any one of the domain is down and when it get up.
    Waiting heartly

    If you really only want scripts you should write them yourself. If you don't understand the script how can you be expected to support it, modify it, or add new features? You don't even indicate what OS your using? I could give you a copy of a powershell script but what good is that on a linux box?
    You need to identify what you really are interested in monitoring. Is it process health only? actual system integrity? Do you need to know if a process count goes under a certain threshold? Is the processes scheduler really working? Is queuing occurring somewhere? Is the web server at a critical number of open sessions? log monitoring for keywords? Do you need to actually simulate a web session which would prove the full system is working in one execution, although it won't indicate a failure will occur where some other monitoring might?
    This is why the others have recommended pre-built packages that already offer most of this. If you still want scripts, gather your requirements, think about what you really need, try some stuff on your own, and if you have a specific problem with a script or how to accomplish a particular system check, post a new question, and I'll do my best to help. I think you'll get a better response from everyone if you do that.

Maybe you are looking for

  • Error while updating, now it will not turn on.

    My friend has had this problem, it is not mine, but she asked me to look into it for her. She was having troubles with her iPod Touch, such as when she was looking through the album view, it would stop playing the song that was currently playing and

  • Java Card Game (Carioca)

    Hi everyone. Im currently making a card game in java for a south american game called Carioca originally i had CariocaController, which controlled game logic such as creating cards and players, dealing the cards setting the cards etc. btnStartGame in

  • Table borders reappear in BI template when file reopened

    Hi, Have come across a frustrating issue with a BI Publisher Template. Using BI Report Publisher, I am putting together a sales invoice which has a bank giro slip at the bottom of the document. Due to the format of the slip with contains a number of

  • Why isn't garage band or imovie or iphoto on my macbook air

    i thought they came with the computer

  • Alphabetical sorting problem

    I have an application which has a drop down loaded with some names. These names are loaded from database which are already sorted alphabetically. But if I test it in IE9, the drop down is not sorted where as it's sorted in other browsers like chrome