SCOM 2012 event id 10801 cluster disks don't discovered.

Hello.
I have errors in Operations Manager log:
Discovery data couldn't be inserted to the database. This could have happened because  of one of the following reasons:
     - Discovery data is stale. The discovery data is generated by an MP recently deleted.
     - Database connectivity problems or database running out of space.
     - Discovery data received is not valid.
 The following details should help to further diagnose:
 DiscoveryId: 5a84ee62-20c2-46a2-10b9-3dedaff65df6
 HealthServiceId: 3aeaca7c-48de-c0fc-0441-ffd5ef7aa7c3
 Microsoft.EnterpriseManagement.Common.DiscoveryDataInvalidRelationshipTargetException,The relationship target specified in the discovery data item is not valid.
Relationship target ID: 2478193e-1a5f-4087-1b5f-95459123321e
Rule ID: 5a84ee62-20c2-46a2-10b9-3dedaff65df6
Instance:
<?xml version="1.0" encoding="utf-16"?><RelationshipInstance TypeId="{acfe2f40-0a73-6764-21a5-bf59c41b2844}" SourceTypeId="{00000000-0000-0000-0000-000000000000}" TargetTypeId="{00000000-0000-0000-0000-000000000000}"><Settings
/><SourceRole><Settings><Setting><Name>5c324096-d928-76db-e9e7-e629dcc261b1</Name><Value>SQL-01</Value></Setting><Setting><Name>af13c36e-9197-95f7-393c-84aa6638fec9</Name><Value>\\.\PHYSICALDRIVE18</Value></Setting></Settings></SourceRole><TargetRole><Settings><Setting><Name>5c324096-d928-76db-e9e7-e629dcc261b1</Name><Value>PDC-S-SQL-01.sibgenco.local</Value></Setting><Setting><Name>af13c36e-9197-95f7-393c-84aa6638fec9</Name><Value>Disk
#18, Partition #0</Value></Setting></Settings></TargetRole></RelationshipInstance>.
SQL-01 is server with clusters disks, and cluster disks are don't discovered.

Hi,
Hope the below articles can be helpful:
Cluster resource groups are not monitored! Is there anything I can do?
http://blogs.msdn.com/b/mariussutara/archive/2008/05/03/cluster-resource-groups-are-not-monitored-is-there-anything-i-can-do.aspx
Event ID 10801 and 33333 in Operations Manager log
http://www.itbl0b.com/2014/02/event-id-10801-33333-operations-manager-log.html#.U-QwunmKBes
Please Note: Since site is not hosted by Microsoft, the link may change without notice. Microsoft does not guarantee the accuracy of this information the web.
Regards, Yan Li

Similar Messages

  • SCOM 2012 - Event ID 6024 (Launching Restart Health Service. Health Service exceeded Process\Handle Count or Private Bytes threshhold.)

    I am getting event ID 6024 (LaunchRestartHealthService.js : Launching Restart Health Service. Health Service exceeded Process\Handle Count or Private Bytes threshhold.) within an interval ranging from 12-17 minutes.
    I am using SCOM (2012 SP1 and 2012 R2) on Windows Server (2008 R2 / 2012 / 2012 R2).
    This issue is occurring only on agent managed computer (acting as proxy and discover managed objects on other computers setting is enabled) which i am using for monitoring my device. All discovery scripts (powershell) and monitors are targeted on this agent
    managed computer.
    There are total 80 discoveries and 900 monitors. 55 discoveries and 550 monitors are enabled by default and rest all are disabled.
    I am seeing event id 6024 frequently only on agent managed computer. Can anyone help me to resolve this issue.
    Thanks,
    Mukul

    To fix issue 6024, you can follow below steps:
    1. Open SCOM console. Go to Monitors -> Agent -> Entity Health -> Performance -> Health Service Performance -> Health Service State.
    2. Double click Health Service Handle Count Threshold monitor and go to Overrides page.
    3. Click Override -> For a specific object of Class: Agent. Select the affected SCOM agent QMXServer.
    4. Check on the parameter Agent Performance Monitor Type - Threshold. Change the default value 2000 to an appropriate value, like 4000. You can check the Health service handle count alert in SCOM console to get the value when the alert is generated. You
    can also launch the health explorer against QMXServer to check the value when the monitor state is changed from healthy to critical.
    Also you can refer below links
    http://blogs.technet.com/b/omx/archive/2013/10/17/health-service-restarts-on-service-manager-servers-with-scom-agents.aspx
    Please remember, if you see a post that helped you please click "Vote As Helpful" and if it answered your question, please click "Mark As Answer"
    Mai Ali | My blog: Technical | Twitter:
    Mai Ali

  • SCOM 2012 Event Log Alarming

    I currently am using a Unit Monitor - Windows Events - Simple Event Detection - Windows Event Reset Monitor.
    This monitor looks for event ID 3003 and looks for "Down" or "Up".  This will open or close an alert depending on its operational status.
    The question/problem I am having is....the application i am monitoring always writes events under event ID 3003.  If I have multiple devices go down at the same time and then go down or come up in a different order, how can I get scom to differentiate
    between the events so its properly opening and closing the correct alerts?
    Your help or ideas are greatly appreciated.
    Thanks!

    The only option is create a event monitor for every devices which spot the event id 3003, event source, I assume that event source is the indication of which device generate the event, and event description is "Up" or "Down". This means
    that you should has 10 rules if you has 10 devices, 20 rules f you has 20 devices.
    Roger

  • SCOM 2012 Event ID 21006 and 21016

    I'm having a connection issue with a newly created gateway server to my management server, that sits in an untrusted DMZ. I have been able to get one gateway working from the DMZ but the one in question is receiving;
    Event ID 21006 :  The OpsMgr Connector could not connect to frw0725.gecio.corp.net:5723.  The error code is 11004L(The requested
    name is valid, but no data of the requested type was found.).  Please verify there is network connectivity, the server is running and has registered it's listening port, and there are no firewalls blocking traffic to the destination.
    Event ID 21016 : OpsMgr was unable to set up a communications channel to frw0725.gecio.corp.net and there are no failover hosts. 
    Communication will resume when frw0725.gecio.corp.net is available and communication from this computer is allowed.
    I have performed the following actions and verifications;
    Services have been restarted on both servers
    certimport has been completed and gatewayapproval has been completed.
    I was able to telnet from MS to GW and from GW to MS, so connection through the firewall is ok.
    DNS appears to be ok, ping’s issued from both servers and they resolve to the correct IP address, however they timeout which is expected
    Event ID 20053 is being received stating that the OpsMgr Connector has loaded the specified authentication certificate successfully.
    I checked the serial number for the personal certificate against what is listed in the registry (reversed) and it matches.
    The Private Key is in place and the cert path is correct
    I also verified in HKLM\Software\Microsoft\Microsoft Operations manager\3.0\Agent Management Groups\" that the correct configuration is being picked up
    I'm looking for some additional guidance or suggestions on what else I can check to get this gateway to show monitored from teh console. Thanks for the help.

    Please check if the certificate was stored in the GW server Computer Personal Store when you first installed it.
    Asuming that the certificate is ok since it is actually working in another GW, perhaps the certificate is in the wrong store (Current User Personal store instead of
    Computer's personal store). In that case you only need to move the certificate to the right store and run momcertimport.exe again. Check Link Below for a detailed step-by-step
    If you still want to clear certificates from the server's personal store, you can do it through both certificates mmc snap-in or certutil.exe -delstore command line
    Also you may want to check this great Step by Step article about installing an OpsMgr GW server:
    http://blogs.technet.com/b/pfesweplat/archive/2012/10/15/step-by-step-walkthrough-installing-an-operations-manager-2012-gateway.aspx 
      Regards

  • SCOM 2012 - Event log analyzing?

    Hey all,
    I am new in scom and have a question about event logs. it is possible to analyze the event logs of servers or can it only use for monitoring of events ?
    Did anybody have more information about that?
    Please help and thanks in advice.

    If you dump those logs on a server with a SCOM agent, you can create a monitor that will use the log reader module to parse through the log to find matching data and raise alerts.  The logs reader provider has a few different types of files it can read.
     Check it out.
    http://social.technet.microsoft.com/Forums/systemcenter/en-US/aa3ad3b8-9a28-48c2-959a-cb628db1d647/text-log-monitorrule-and-cleared-logfile?forum=operationsmanagerauthoring
    Regards, Blake Email: mengotto<at>hotmail.com Blog: http://discussitnow.wordpress.com/ If my response was helpful, please mark it as so, if it answered your question, then please also mark it accordingly. Thank you.

  • Guide to productively use SCOM 2012 ?

    Hello everyone,
    I am having a hard time trying to find what to do with the SCOM 2012 R2 UR4 installation I have done. I personally think that SCOM has a very steep learning curve. Seems to me one needs a PhD degree in rocket science to be able to fully use SCOM!!
    Other monitoring tools like (spiceworks) are so very easy to setup and use.
    I wish someone could tell me (in plain words) what is the sequence of things a SCOM admin should do to be productive.
    Is there a guide out there?
    Here are some of the questions I still have in my mind:
    I have SCOM installed, now what?
    I am supposed to install agents on all my 150+ servers or just a few?
    How can I make sure SCOM watches over the servers? (warn me for simple things like disk space, CPU pegged etc)
    Create dashboards on a wall mounted display?
    Here is what I have been able to do until now...done the installation.... started monitoring a couple of web applications...you know... basic website is up/down notifications. But I wanna do more.
    Please help me!
    -Rajeev rajdude.com

    SCOM is a sophisticated monitoring tool and has a easy setup and use characteristic.
    1) Built up SCOM infrastructure: SCOM Managment Server, DB Server, SCOM console and SCOM reporting 
    http://blogs.technet.com/b/kevinholman/archive/2013/10/18/opsmgr-2012-r2-quickstart-deployment-guide.aspx
    2) Deploy SCOM Agents to machines which you want to monitor: In your situation, i recommend that you should deploy SCOM agent to 150+ server by using discovery method
    http://prajwaldesai.com/installing-scom-agent-on-windows-based-computers/
    3) Deploy rquired MP:In your situation, it is recommend that Windows OS MP should be installed and the latest version should be downloaded from
    http://www.microsoft.com/en-hk/download/details.aspx?id=9296
    4) Create dashboards:http://blogs.technet.com/b/momteam/archive/2011/09/27/introducing-operations-manager-2012-dashboards.aspx
    5) If you want to receive email alert in addition to SCOM alert, you should configure email notification and subscription:http://blogs.technet.com/b/kevinholman/archive/2012/04/28/opsmgr-2012-configure-notifications.aspx
    6) Tunning threshold for your environment
       There are serveral built-in performance based monitors in Windows OS MP which need you attention. By deafult, Windows OS built-in monitors threshold is good but may not fit your company requirement which you should change it vale by using override
       a) Disk space monitor:
          - Windows XXX Logical Disk Space monitor:
            System Disk:
                Warning: free space below 10% and 500MB
                Error: free space below 5% and 300MB
            Non-system Disk:
                Warning: free space below 10% and 2000MB
                Error: free space below 5% and 1000MB
          - Windows XXX Logical Disk Free Space (%) Low:
            System Disk:
                Warning: free space below 10% for 1 hour
                Error: free space below 5% for 1 hour
            Non-system Disk:
                Warning: free space below 10% for 1 hour
                Error: free space below 5% for 1 hour
          - Winodws XXX Logical Disk Free Space (MB) Low:
            System Disk:
                Warning: free space below 500MB for 1 hour
                Error: free space below 300MB for 1 hour
            Non-system Disk:
                Warning: free space below 2000MB for 1 hour
                Error: free space below 1000MB for 1 hour
           Pay attention: By default, Windows XXX Logical Disk Free Space (%) Low and Winodws XXX Logical Disk Free Space (MB) Low is no enabled.
       b) Processor usage:
          - total CPU utilization Percentage: The default threshold is more than 95 % and CPU Queue length more than 15 for more than 45 minutes
       c) Memory usage:
          - Available megabytes of memory:Default threshold is below 100Mb for 45 minutes
    Roger

  • SCOM 2012 SP1 UR4 management servers grey state

    Hi,
    My SCOM environment is made up of the below :-
    SCOM 2012 SP1 UR4.
    3 SCOM Management Servers all on Windows 2008 R2 SP1.
    Shared SQL 2008 cluster with 2 Windows nodes also on same OS.
    Just recently all our SCOM management servers have been flipping in and out from grey to green state.  Gateways/agents all look ok as showing green.  Alerting from agents appears normal as can see lots of them in console.
    Have flushed the health state cache folder on all 3 SCOM MS's and still the same issue.
    Appreciate any help on this one.

    Event id: 7011 - Was your server recently patched (Installed by any automatic updates) ?
    IS SCCM Configured in your MS? If Yes disable and check?
    Is Windows update service running ? Stop if for one or two days and check if this issue still appears
    Reference threads:
    http://social.technet.microsoft.com/Forums/en-US/b86e5a3d-0c2e-4d5e-9d3d-905da91fc982/scom-2012-event-id-7011-service-control-manager-error-when-fep-definition-updates-apply?forum=configmanagersecurity
    http://stefanroth.net/2012/09/26/scom-2012-event-id-7011-service-control-manager-error/
    Solution also available in: http://technet.microsoft.com/en-us/library/cc756319(v=ws.10).aspx
    ===========================================
    For Event id 20026 - 
    1. Does your Operationsmanager database have enough space ? Check that first.
    What is you DB size ?
    How much is the free space left ?
    2. Was there any resent change in the SCOM Action accoutn password ? Or has the password expired. Try re entering the SCOM Action password by re directing your self to Administration tab --> Run as Config -- > Accounts --> SCOM Action account.
    The description would be - This is the user account under which all rules run by default on the agent.
    Right click and go to properties and re enter the account name and password there and check.
    Refer the below screen shot
    Check this article as well:
    http://social.technet.microsoft.com/Forums/systemcenter/en-US/102d443c-db0e-4bf2-b0d6-31d7f9328537/all-agents-greyed-out-multiple-event-errors-with-ids-20026-20028?forum=operationsmanagergeneral
    ============================================
    Event id : 11904 - As per my knowledge appears due to incorrect Alrting string display name selected in any Rule or monitor.
    Also the description what you pasted in Event id : 11904 says Microsoft.SystemCenter.HealthService.ActionAccountConfigured.Error as highlighted below.
    Suggest to re enter the action account password and tell the results.
    Also is the Healthservice on the MS running using System account or Domain account ?
    =================================================================
    Description : The Microsoft Operations Manager Expression filter Module failed to query the delivered item, item was dropped.
    Property Expression: Reachability/State
    Error : 0XC00EE22
    One or more workflows were affected by this. Workflow
    name: Microsoft.SystemCenter.HealthService.ActionAccountConfigured.Error
    Gautam.75801

  • SCOM 2012 Agent - Best Practices with Base Images

    I've read through the
    SCOM 2012 agent installation methods technet article, as well as how to
    install the SCOM 2012 agent via command line, but don't see any best practices in regards to how to include the SCOM 2012 agent in a base workstation image. My understanding is that the SCOM agent's unique identifier is created at the time of client installation,
    is this correct? I need to ensure that this is a supported configuration before I can recommend it. 
    If it is supported, and it does work the way I think it does, I'm trying to find out a way to strip out the unique information so that a new client GUID will be created after the machine is sysprepped, similar to how the SCCM client should be stripped of
    unique data when preparing a base image. 
    Has anyone successfully included a SCOM 2012 (or 2007 for that matter) agent in their base image?
    Thanks, 
    Joe

    Hi
    It is fine to build the agent into a base image but you then need to have a way to assign the agent to a management group. SCOM does this via AD Integration:
    http://technet.microsoft.com/en-us/library/cc950514.aspx
    http://blogs.msdn.com/b/steverac/archive/2008/03/20/opsmgr-ad-integration-how-it-works.aspx
    http://blogs.technet.com/b/jonathanalmquist/archive/2010/06/14/ad-integration-considerations.aspx
    http://thoughtsonopsmgr.blogspot.co.uk/2010/07/active-directory-ad-integration-when-to.html
    http://technet.microsoft.com/en-us/library/hh212922.aspx
    http://blogs.technet.com/b/momteam/archive/2008/01/02/understanding-how-active-directory-integration-feature-works-in-opsmgr-2007.aspx
    You have to be careful in environments with multiple forests if no trust exists.
    http://blogs.technet.com/b/smsandmom/archive/2008/05/21/opsmgr-2007-how-to-enable-ad-integration-for-an-untrusted-domain.aspx
    http://rburri.wordpress.com/2008/12/03/untrusted-ad-integration-suppress-misleading-runas-alerts/
    You might also want to consider group policy or SCCM as methods for installing agents.
    Cheers
    Graham
    Regards Graham New System Center 2012 Blog! -
    http://www.systemcentersolutions.co.uk
    View OpsMgr tips and tricks at
    http://systemcentersolutions.wordpress.com/

  • Logical Disk space on a virtual Computer (not a Server) in SCOM 2012

    Hello all-
       I have a sort of unique situation for our SCOM environment.  We are already doing logical disk space monitoring on all of our SERVERS with no issues.  Now we have one user who requires monitoring on their computer.  This is really
    a virtual workstation, as opposed to a real computer.   Since it's virtual, it's really online all the time.    Whether its right or wrong, they are using this virtual workstation sort of as a server.  Anyway, they want me to
    monitor the disk space for the C drive on this virtual computer.  I'm having difficulty setting up such a monitor on a computer like that...
    I got the SCOM agent installed onto the computer.  SCOM is reporting it as being "Healthy".   Now how can I define a logical disk space monitor for it?   I attempt to create a monitor:   Windows Performance Counters,
    Static Thresholds, Single Threshold.  Then how can I direct the monitor at the C drive on the computer?  I have to fill in the Object, Counter and Instanace.  Normally I would click on the
    Select button, then I would type in the server name and hit Enter and it would bring up all the objects it will allow me to monitor.  Unfortunately it doesn't let me type in the computer name and hit enter in the same way.  When I
    do so, it says "The network path was not found".  If I click on the
    ... button next to the Computer field, it brings me to a Select Computer screen.  In here, I am type in the computer name and then I click
    Check Name and it does appear to find it, and it underlines the computer's name.    So I then click
    OK to bring me back to the previous screen where it presents me with the same  "The network path was not found" error immediately. So I can't seem to navigate to the computer in SCOM and select the C drive, as I would be able
    to for a server.
    I tried to sort of force it in, instead of browsing for the computer and selecting the C drive.  I simply put
    LogicalDisk in for the Object then Free Megabytes for the Counter, then
    C: for the Instance (as shown in the attached screen print.
    Then I just applied my new rule to the computer via SCOM.  I don't get any error messages when setting it up that way, but it certainly doesn't work.
    So with all that said, can anyone help me out setting up a logical disk space monitoring for a COMPUTER in SCOM 2012 SP1 please?  Please let me know if you need any more information!

    Thanks, that would probably do it, I'm going to keep that as my backup plan.  However, my current feeling is that it might be a bit overkill to install a whole management pack, when all I want to do is monitor a single C drive on a single workstation. 
    The rest of the monitors in the management pack I wouldn't have any interest it.   Let me ask you a question maybe you will know the answer to... Shouldn't I be able to monitor that drive even without that management pack installed?   I
    mean some combination of settings for the Logical Disk Space rule in that management pack works for computers/workstations.  Shouldn't I be able to reproduce that one single rule without the management pack?  Does anyone have that management pack
    installed?  Could you possibly look at the Client OS Logical Disk Space rule and send me some screen shots or something?   Or am I missing something?  Is the management pack needed for other reasons in order to monitor this?

  • Cannot add cluster disk on windows 2012

    I have 2 servers connected to a shared storage array using Fibre Channel.  Currently there are 2 luns on the storage device.  
    From the Failover Cluster Manager, when I select “Add Disk” from Storage – Disks, both luns show up and I can add them without problems.  But if I choose to only
    add one of them first (it doesn't make a difference which one is added first), then it will not allow adding the second one later.  I get a message: "No disks suitable for cluster disks were found. For diagnostic information about disks available to the
    cluster, use Validate a Configuration Wizard to run Storage tests."
    When I do add one (or both disks at the same time), they work just fine for failover clustering.
    I can’t imagine this is by design. Is this a known/unknown issue, or is there something special that needs to be done?
    Thanks

    Ok, no problem. I run the validation tests (Validate Cluster - Storage only) and I received the details shown below. I can clearly see that Cluster Validation tool does not find any disk suitable for 2012 cluster, and even I can see why (it is plain English).
    Unfortunately this still does not explain how to fix the problem. Recommendations like "run Clear-ClusterDiskReservation PowerShell cmdlet to remove the Persistent Reservation from the disk" do not work - this discussion is available in another thread where
    people having the same issue and no luck so far. I guess that I'm using old SAN (and I know that) that simply does not support SCSI-3 persistent reservation so those disks cannot be used in 2012 cluster. Oh well, will have to wait fro new SAN and then I can
    play again...
    Validation test results:
    Physical disk with identifier {95059d50-a173-49bd-b029-fec326acd78c} has an existing Persistent Reservation placed on it, and will be removed from the validation set. This disk may already be clustered, on a different cluster or in use by another system.
    Please verify the storage configuration and LUN zoning. If you wish to cluster this disk, you can use the Clear-ClusterDiskReservation PowerShell cmdlet to remove the Persistent Reservation from the disk.
    Physical disk with identifier {0b301c72-c88f-47ee-9389-11efdeed6cdb} has an existing Persistent Reservation placed on it, and will be removed from the validation set. This disk may already be clustered, on a different cluster or in use by another system.
    Please verify the storage configuration and LUN zoning. If you wish to cluster this disk, you can use the Clear-ClusterDiskReservation PowerShell cmdlet to remove the Persistent Reservation from the disk.
    Physical disk with identifier {eec0be37-5dfe-47f7-a149-4f1dec18450b} has an existing Persistent Reservation placed on it, and will be removed from the validation set. This disk may already be clustered, on a different cluster or in use by another system.
    Please verify the storage configuration and LUN zoning. If you wish to cluster this disk, you can use the Clear-ClusterDiskReservation PowerShell cmdlet to remove the Persistent Reservation from the disk.
    Physical disk with identifier {dcb8b1fe-7671-41c9-b996-da26c0b93751} has an existing Persistent Reservation placed on it, and will be removed from the validation set. This disk may already be clustered, on a different cluster or in use by another system.
    Please verify the storage configuration and LUN zoning. If you wish to cluster this disk, you can use the Clear-ClusterDiskReservation PowerShell cmdlet to remove the Persistent Reservation from the disk.
    No disks were found on which to perform cluster validation tests. To correct this, review the following possible causes:
    * The disks are already clustered and currently Online in the cluster. When testing a working cluster, ensure that the disks that you want to test are Offline in the cluster.
    * The disks are unsuitable for clustering. Boot volumes, system volumes, disks used for paging or dump files, etc., are examples of disks unsuitable for clustering.
    * Review the "List Disks" test. Ensure that the disks you want to test are unmasked, that is, your masking or zoning does not prevent access to the disks. If the disks seem to be unmasked or zoned correctly but could not be tested, try restarting the servers
    before running the validation tests again.
    * The cluster does not use shared storage. A cluster must use a hardware solution based either on shared storage or on replication between nodes. If your solution is based on replication between nodes, you do not need to rerun Storage tests. Instead, work
    with the provider of your replication solution to ensure that replicated copies of the cluster configuration database can be maintained across the nodes.
    * The disks are Online in the cluster and are in maintenance mode. No disks were found on which to perform cluster validation tests.

  • System center data access service crashes with event id 26339 ad 26380 in SCOM 2012 Sp1 RTM

    hi all,
    I have deployed scom 2012 sp1 rtm on Os 2012 std and database is on another VM Machine having SQL 2012 sp1 with OS 2008 R2 SP1 std, suddenly sql vm get stopped and unable to start , so I have delete it from hyper-v 2012 console and imported the VM again
    in Hyper-0S 2012 cluster.
    Now, System centre data access service get crashed again and again with mentioned events
    event 26339, OpsMgr SDKService
    event 26380, opsmgr SDkService
    An exception was thrown while initializing the service container.
    Exception message: Initialize
    Full exception: HTTP could not register URL
    http://+:51905/ConnectorFramework/ because TCP port 51905 is being used by another application.
    The System Center Data Access service failed due to an unhandled exception. 
    The service will attempt to restart.
    Exception:
    System.ServiceModel.AddressAlreadyInUseException: HTTP could not register URL http://+:51905/ConnectorFramework/ because TCP port 51905 is being used by another application. ---> System.Net.HttpListenerException: The process cannot access the file
    because it is being used by another process
       at System.Net.HttpListener.AddAllPrefixes()
       at System.Net.HttpListener.Start()
       at System.ServiceModel.Channels.SharedHttpTransportManager.OnOpen()
       --- End of inner exception stack trace ---
       at System.ServiceModel.Channels.SharedHttpTransportManager.OnOpen()
       at System.ServiceModel.Channels.TransportManager.Open(TransportChannelListener channelListener)
       at System.ServiceModel.Channels.TransportManagerContainer.Open(SelectTransportManagersCallback selectTransportManagerCallback)
       at System.ServiceModel.Channels.HttpChannelListener`1.OnOpen(TimeSpan timeout)
       at System.ServiceModel.Channels.CommunicationObject.Open(TimeSpan timeout)
       at System.ServiceModel.Dispatcher.ChannelDispatcher.OnOpen(TimeSpan timeout)
       at System.ServiceModel.Channels.CommunicationObject.Open(TimeSpan timeout)
       at System.ServiceModel.ServiceHostBase.OnOpen(TimeSpan timeout)
       at System.ServiceModel.Channels.CommunicationObject.Open(TimeSpan timeout)
       at Microsoft.EnterpriseManagement.ConnectorFramework.ServiceDataLayer.ConnectorFrameworkDataAccessChannel.Initialize()
       at Microsoft.EnterpriseManagement.ServiceDataLayer.DispatcherService.Initialize(InProcEnterpriseManagementConnectionSettings configuration)
       at Microsoft.EnterpriseManagement.ServiceDataLayer.DispatcherService.InitializeRunner(Object state)
       at System.Threading.ExecutionContext.RunInternal(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean preserveSyncCtx)
       at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean preserveSyncCtx)
       at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state)
    Kirpal Singh

    Hi Kirpal
    Can you try this it might help as its an known issue of getting event id 's 26361,26380 try out & lets see if it helps.
    The manifest files are located on the RMS at the \Program Files\System Center Operations Manager 2007\ root directory. The manifest files will need to be edited for the config and sdk service on affected RMS. The file names are:
    Microsoft.Mom.Sdk.ServiceHost.exe.config
    Microsoft.Mom.ConfigServiceHost.exe.config
    In between the EXISTING <runtime> and </runtime> lines – you need to ADD a NEW LINE with the following:
    <generatePublisherEvidence enabled="false"/>
    This solution disables CRL checking for the specified execute-ables, permanently.

  • Creating SCOM 2012 Logical Disk Space Availability View

    Hi Everyone,
    I am looking to create a SCOM 2012 Logical Disk Space Availability View and having a little trouble finding documentation on how to do this. It would be really handy to see all of the servers being monitored and how much free space they have all in one view.
    Has anyone created a view like this before.
    Thanks in advance for all your help.
    JD

    Hi,
    Below are some blogs that will help you to understand more about disk space monitoring
    Writing monitors to target Logical or Physical Disks
    http://blogs.technet.com/b/kevinholman/archive/2009/11/24/writing-monitors-to-target-logical-or-physical-disks.aspx
    OpsMgr: Logical Disk free space alerts don’t show percent and MB free values in the alert description
    http://blogs.technet.com/b/kevinholman/archive/2011/11/17/opsmgr-logical-disk-free-space-alerts-don-t-show-percent-and-mb-free-values-in-the-alert-description.aspx 
    Thanks.
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • SCOM 2012 SP1 Datawarehouse event id 31553 and after 2 minutes successful id 31572

    Hello guys,
    I'm running SCOM 2012 SP1 and in one of my 3 Management groups i got the following events. I get them every few minutes and i cannot explain it. I have checked the aggregation of the DW and its fine. I Have extended the timeout from 5 to 15 minutes ... What
    should i do next. Please help with this. I have checked all 2007 posts but they are not related to my problem. I have tried a number of queries but they don't return any result. Do I have a SQL server performance issue ?
    Date and Time:
    10/27/2014 11:05:10 AM
    Log Name:
    Operations Manager
    Source:
    Health Service Modules
    Generating Rule:
    Data Warehouse related event collection
    Event Number:
    31553
    Level:
     Error
    Logging Computer:
    User:
    N/A
    Description:
    Data was written to the Data Warehouse staging area but processing failed on one of the subsequent operations. Exception 'SqlException': Transaction (Process ID 71) was deadlocked on lock resources with another process and has been chosen as the deadlock
    victim. Rerun the transaction.
    One or more workflows were affected by this.
    Workflow name: Microsoft.SystemCenter.DataWarehouse.CollectPerformanceData
    Instance name: server2.mymg.corp
    Instance ID: {EBD49B2A-D314-07DF-9E2C-B79CF86B1A72}
    Management group: MyMG
    Date and Time:
    10/27/2014 11:26:36 AM
    Log Name:
    Operations Manager
    Source:
    Health Service Modules
    Generating Rule:
    Data Warehouse related event collection
    Event Number:
    31553
    Level:
     Error
    Logging Computer:
    server10.mymg.corp
    User:
    N/A
    Description:
    Data was written to the Data Warehouse staging area but processing failed on one of the subsequent operations. Exception 'SqlException': Transaction (Process ID 68) was deadlocked on lock resources with another process and has been chosen as the deadlock
    victim. Rerun the transaction.
    One or more workflows were affected by this.
    Workflow name: Microsoft.SystemCenter.DataWarehouse.CollectPerformanceData
    Instance name: server10.mymg.corp
    Instance ID: {DBDD19A5-98B3-F90A-641E-7C4693BFD6EB}
    Management group: MyMG
    Event Data:
     View Event Data
    < DataItem
    type ="
    System.XmlData "
    time =" 2014-10-27T11:26:36.2773982-05:00
    " sourceHealthServiceId
    =" DBDD19A5-98B3-F90A-641E-7C4693BFD6EB
    " >
    < EventData
    >
    < Data > MyMG</
    Data >
    < Data >
    Microsoft.SystemCenter.DataWarehouse.CollectPerformanceData
    </ Data
    >
    < Data > server10.mymg.corp
    </ Data
    >
    < Data >
    {DBDD19A5-98B3-F90A-641E-7C4693BFD6EB}
    </ Data >
    < Data >
    SqlException </
    Data >
    < Data >
    Transaction (Process ID 68) was deadlocked on lock resources with another process and has been chosen as the deadlock victim. Rerun the transaction.
    </ Data
    >
    </ EventData
    >
    </ DataItem
    >
    User:
    N/A
    After 2 minutes i will have the 31572 which is
    Data writer successfully performed data maintenance operations. What would be the reason for this ?

    There are a few things that can cause this. Your hint here is the deadlock message; processes are competing to write data in the DW, so you need to find out what that is. You also have a message stating that data is written to staging, but timing out moving
    the data. If you happen to be running the Exchange MP, this creates an additional data set that can quietly clog up the works--but you would see that dataset in the event message as well.
    Because you say aggregation is moving, try following these steps, they have served me well. I think you are seeing the results of data getting 'stuck' that causes the system to slowly choke itself. Note: You can focus on just the perf dataset, but always
    a good idea to make sure everything is healthy while you're at it.
    Steps:
    Check to see if the staging area for data written to the DW is clear and data is moving:
    select count(*) from Alert.AlertStage
    select count (*) from Event.eventstage
    select count (*) from Perf.PerformanceStage
    select count (*) from state.statestage
    These values normally rise and fall rapidly. If you open each table, they should also only contain recent data. If you find any data points older than a day, something is stuck. In one case I found state.statestage stuck around 14300. A look at the data
    showed a few hundred rows of data that had information 4 months old.
    See if data is moving (if you have old data, the answer is evident):
    1. select * from StandardDataset
    2. Plug the appropriate GUID into exec StandardDatasetMaintenance @DatasetId='<GUID from query>'
    3. See if the count decreases
    If it doesn't, if the data is expendable, just truncate the table (don't be afraid to do this--if OpsMgr is choking, stop the choking, and don't fret over missing data points)
    truncate table state.statechange
    Optional query:
    Plug the DatasetId into the below query
    USE [OperationsManagerDW]
    DECLARE @DataSet uniqueidentifier
    SET @DataSet = (SELECT DatasetId FROM StandardDataset WHERE DatasetId = '138B1324-BE31-42D7-A6CB-EA10139E309C')
    EXEC StandardDatasetMaintenance @DataSet
    Note: Valid current values are Event, Alert, CM, Perf, State
    If these check out, it's time to
    See if any SQL jobs are running that could be interfering
    If you are not out of space, but close, and autogrow is killing your performance
    Run the large table query to see if you have unchecked perf data growth that exceeds the performance capability of the SQL box
    You may indeed have a SQL performance issue, but that's the last thing you troubleshoot--make sure OpsMgr is healthy first

  • SCOM 2012 R2 Exchange Correlation Service , we receive almost at every day in the Event log Application the Event720

    HI
    Since the SCOM was Upgrade to R2 
    Almost at every Day, we receive in the Event log application the Event 720 from the correlation service Source MSExchangeMonitoring Correlation
    This arrives always around 7:20AM, someday is at 7:19, other at 7:21. It is always approximately at the same hour, but we never have any problem during weekend
    The description of the Event
    Exceeded maximum time (15 minutes) to wait for completion of all CorrelateBatchTask threads.
    After that the correlation stop to work. At the Same time if we tried to open the SCOM Console on that server we was unable to open it. Also we was not able to open the SCOM PowerShell
    And also we cannot from that server to get which server is the RMS if we run get-SCOMRMSEmulator .  (This the RMS Server)
    When this arrive, the only thing we found, it to reboot the server or restart de SCOM service, after the Reboot the Correlation begin to work
    We got also many Event 714 Critical and after this Event 711 Warning
    Thank

    Have a look at: https://social.technet.microsoft.com/Forums/systemcenter/en-US/e75e84d9-0c9e-4d83-b3da-45a143757f85/exchange-2010-monitoring-with-scom-2012-correlation-service-issue
    One user reported an issue with the exchange correlation engine after upgrade and said that:
    I had issues with the corellation engine after upgrading scom 2012 to R2.
    The MomBidLdr.dll version changed in the SCOM directories, and needs to be updated in the:
    C:\Program Files\Microsoft\Exchange Server\v14\Bin directory.
    That seemed to stop the errors for me.
    Some troubleshooting steps listed here also:
    https://technet.microsoft.com/en-us/library/ff360495(v=exchg.140).aspx
    Cheers,
    Martin
    Blog:
    http://sustaslog.wordpress.com 
    LinkedIn:
    Note: Posts are provided “AS IS” without warranty of any kind, either expressed or implied, including but not limited to the implied warranties of merchantability and/or fitness for a particular purpose.

  • SCOM 2012 R2 installtion wizard not able to contact SQL server cluster

    Hi,
    This is about the error faced while installing SCOM 2012 R2.
    My customer has SQL 2012 SP1 cluster installed. I am trying to install the SCOM 2012 R2 with this installed SQL cluster. The SQL cluster is installed with default instance and with AAG (Always on Availability Group).
    The edition of SQL server is, SQL Server Enterprise edition with SP1
    After check services on both the SQL nodes found that SQL Full text is not installed (as the related SQL Full text service not present in the services.msc) on any of the SQL cluster node & SQL Browser service is not running.
    The running services for SQL are, SQL Server (MSSQLSERVER) & SQL Server Agent (MSSQLSERVER).
    When I started to install the SCOM 2012 R2, Within a SCOM 2012 wizard, On the Configure the Operational Database screen, entered only the name of SQL cluster & no instance as it is with default instance MSSQLSERVER.
    I faced error as, This SQL Server could not be found.
    After installed SQL full text, the service is showing in services.msc as "SQL Full-text Filter Daemon Launcher (MSSQLSERVER)".
    Now when I started to install the SCOM 2012 R2, Within a SCOM 2012 wizard, On the Configure the Operational Database screen, entered only the name of SQL cluster & no instance as it is with default instance MSSQLSERVER.
    I faced error as, The installed version of SQL Server could not be verified or is not supported. 
    Followings test carried out for the connectivity between SCOM 2012 MS &SQL Cluster
    Ping SQL Cluster successfully
    Telnet SQL Cluster for port 1433 successfully
    Tracert SQL Cluster – completed successfully with single hops.
    The windows firewall is off on both sides
    The SQL services running on the Active node 1 of the cluster are as follows:
    SQL Full Text Filter Daemon Launcher (MSSQLSERVER) -- Running & Manual
    SQL Server (MSSQLSERVER) -- Running & Automatic
    SQL Server Agent (MSSQLSERVER) -- Running & Automatic
    SQL serve Browser - Stopped & Manual
    SQL Server VSS Writer -- Running & Automatic
     The SQL services running on the Passive node 2 of the cluster are as follows:
    SQL Full Text Filter Daemon Launcher (MSSQLSERVER) -- Running & Manual
    SQL Server (MSSQLSERVER) -- Running & Automatic
    SQL Server Agent (MSSQLSERVER) -- Stopped & Automatic
    SQL serve Browser - Stopped & Manual
    SQL Server VSS Writer -- Running & Automatic
    The SQL Server Agent (MSSQLSERVER) service is not running on the second node. It is running only on first node which is active.
    The account used to install SCOM has the local admin privilege on the SQL server
    To ping the cluster use the cluster name & it solved the whole FQDN of cluster in ping result. When ping with IP address with -a it not resolve to name.
    Is any one can provide their valuable inputs.
    Regards,
    SandeepK

    Hi SandeepK,
    Before Installing Operations Manager on an availability group, please
    1. Make sure to use the Group listener Name and port when installing Operations Manager for the databases that are going to be added to the availability databases.
    2. The first management server will use the Group listener to get the primary SQL instance, and will install the databases on that instance.
    System Requirements: System Center 2012 R2 Operations Manager
    http://technet.microsoft.com/en-us/library/dn249696.aspx#BKMK_ClusterConfig
    Niki Han
    TechNet Community Support

Maybe you are looking for

  • Facetime on 2 ios devices

    trying to use 2 ios devices linked to the same apple id, set up different emails in each but the recipient device just rings once then says "xxxx is busy" does it make any difference being on the same wireless network? wouldnt have thought so, where

  • Using iMac as Home Stereo

    Is there a way to use my iMac Intel as my home stereo? I have an old receiver that isn't working anymore. I just had my kitchen redone, and my brother-in-law (the electrician) put in speaker wires to my deck and in my kitchen/new bar area. All of my

  • Question related to webgate

    When a request comes to a webserver having webgate installed, the webgate contact Policy Manager to check for authenitcation/authorization required. The Policy Manager contact the LDAP to check that. This will happen to all the resource on that webse

  • Synch/Asynch Bridge TimeOut

    Hi, I am sending data to R/3 system through XI and waiting for response. If the R/3 takes half an hour to respond will my Synch/Asynch bridge will be still waiting for the response or will it die because of TIME_OUT. Can anyone let me know. Regards,

  • Question:  m4a vs. m4p, & movie trailers not showing up

    In the past, when I downloaded tunes from the iTunes Store, they would be in .m4a format. Now, all my new downloads are in the .m4p format. What is the difference between the 2 formats. What can I do with them....burn audio cd's? Next, I d/l'd the ne