SCOM 2012 Web Transaction alerting after second bad poll

I'm trying to create a synthetic web transaction that will raise an alert after the second bad occurrence.  Anybody have any idea as to how to accomplish this to filter hair trigger errors.

More info:
SCOM 2012 - Monitoring the System Center 2012 App Controller Website
http://kevingreeneitblog.blogspot.com/2012/01/scom-2012-monitoring-system-center-2012.html
Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

Similar Messages

  • Service Monitoring in SCOM which triggers an alert after a wait time

    Hi ,
    I have a requirement to amend on of our services monitors to alert after waiting for 3 minutes after the service goes down.
    Is this possible using SCOM or do we need to script this.
    Please advise.
    Jesty

    For configure that using script, you can refer below link
    http://blogs.technet.com/b/fesiro/archive/2012/11/26/how-to-configure-command-notification-in-scom-2012-with-powershell-script.aspx
    Please remember, if you see a post that helped you please click "Vote As Helpful" and if it answered your question, please click "Mark As Answer"
    Mai Ali | My blog: Technical | Twitter:
    Mai Ali

  • SCOM 2012 Web part won't show up in SharePoint 2013

    Hi
    I'm using SCOM 2012 en installed a test server with SharePoint 2013. I executed the command to install the operationsmanager dashboardviewer:
    .\INSTALL-OPERATIONSMANAGER-DASHBOARDVIEWER.PS1 "C:\TEMP " http://localhost:9000
    Everything went well.
    I activated it under site collection features in sharepoint.
    Under Site Contents > Operations Manager Web Console Environments > Edit i put the correct settings in.
    After that I mad a new web application (since it was a new sharepoint server) and
    affter that i created a site collection. (Collaboration > Team site)
    When i surf to my newly created site, and i choose Add a page > Insert > Web Part, my SCOM plugin doesn't show up. According to several guides there should
    be a categorie "Microsoft System Center" and a webpart "Operations Manager Dashboard", but it doesn't show up.
    Does anyone have an idea how to fix this :s?

    Disclaimer: I know nothing of SCOM's SP integration.
    it sounds like the feature isn't activated at the site collection level... perhaps the powershell script was supposed to be run AFTER the site collection was created? You might be able to activate the feature afterwards, but it may not be very straight forward
    (they may be hidden).
    Scott Brickey
    MCTS, MCPD, MCITP
    www.sbrickey.com
    Strategic Data Systems - for all your SharePoint needs

  • How to use the SCOM 2012 Web Reporting page

    Hello all-
       We are on SCOM 2012 SP1.  I just have a general question about reporting.  I know there is a "Reporting" tab in the real, locally installed, SCOM Operations Console software.  That part I get.  I see that there
    are many pre-made reports the for me to run.  For example under Microsoft Server 2008 Operating System (Monitoring) folder there is a
    Performance History report.  When I double click on it, it takes me to the report window where I can click
    Add Object and add a server and then click
    Run.  
    This is pretty simple in concept.   BUT very few people at my company have the full Operations Console installed on their machine.  And as I'm sure you know, the SCOM Web Console does not have a Reporting Tab.  So they have to use the
    SCOM Reporting website to run such reports.  I found that you can get to this page at the url:
    http://<reporting server>/Reports                       
    This does bring up the Reporting console.  On the list I do see a Report.Windows.Server.2008.PerformanceHistory listed. So this surely seems to be the equivalent from my screenshot above.   However, it's not even close to user friendly like
    the Reporting area in the SCOM operations console software. There's multiple fields at the top. All of which are required, and almost none of which have dropbox or other ways to help you fill them in. I have no idea what to put into these boxes or the format
    to use.
    What am I missing here?  Is there a more user friendly interface anywhere?  In an ideal world, I'd really love to have a user interface where I can post the links to a few popular reports, like CPU and Disk Space for example.  Then ideally
    all the user would have to do is select their servers and the time frame and that's all.   Which really is what you do in the Operations Console software.   So isn't is it that easy in the web reporting tool?  Is there a guide or how-to
    section somewhere I'm missing?  Or just a more friendly looking way to get at this information?

    Well, my first screen shot above is squished, so you really can't see it.  But what I'm saying is that the same report in the SCOM software has the level of configuration I want on it.   It allows you to pick the date range and add objects
    to it, then you can click on Run.     However when I access the same report on the reporting console, it has all these extra fields.  None of which I know how to fill in properly.
    I would ultimately like my customers to be able to do exactly that in the web version.  Pick their server and their date range and run it.   There are not likely going to be too many reports like you're mentioning which I can completely configure
    before hand, so they just click on the link to have it run.  Most times I'd like my users to at least be able to select a server name.
    Any idea how I would simplify the web version of the report?  Or why they look so very different?

  • SCOM 2012 Web Console "An unexpected error has occurred"

    Hi,
    We have installed a new scom 2012 with CU3, when accesing the web console we  receive this error message:
    Please provide the following information to the support engineer if you have to contact Microsoft Help and Support :
    System.ServiceModel.CommunicationException: [HttpWebRequest_WebException_RemoteServer]
    Arguments: NotFound
    Debugging resource strings are unavailable. Often the key and arguments provide sufficient information to diagnose the problem. See System.Net.WebException: [HttpWebRequest_WebException_RemoteServer]
    Arguments: NotFound
    Debugging resource strings are unavailable. Often the key and arguments provide sufficient information to diagnose the problem. See System.Net.WebException: [HttpWebRequest_WebException_RemoteServer]
    Arguments: NotFound
    Debugging resource strings are unavailable. Often the key and arguments provide sufficient information to diagnose the problem. See at System.Net.Browser.BrowserHttpWebRequest.InternalEndGetResponse(IAsyncResult asyncResult)
       at System.Net.Browser.BrowserHttpWebRequest.<>c__DisplayClassa.<EndGetResponse>b__9(Object sendState)
       at System.Net.Browser.AsyncHelper.<>c__DisplayClass4.<BeginOnUI>b__0(Object sendState)
       --- End of inner exception stack trace ---
       at System.Net.Browser.AsyncHelper.BeginOnUI(SendOrPostCallback beginMethod, Object state)
       at System.Net.Browser.BrowserHttpWebRequest.EndGetResponse(IAsyncResult asyncResult)
       at System.ServiceModel.Channels.HttpChannelFactory.HttpRequestChannel.HttpChannelAsyncRequest.CompleteGetResponse(IAsyncResult result)
       --- End of inner exception stack trace ---
       at System.ServiceModel.AsyncResult.End[TAsyncResult](IAsyncResult result)
       at System.ServiceModel.Channels.ServiceChannel.EndCall(String action, Object[] outs, IAsyncResult result)
       at System.ServiceModel.ClientBase`1.ChannelBase`1.EndInvoke(String methodName, Object[] args, IAsyncResult result)
       at Microsoft.EnterpriseManagement.Presentation.Security.ServiceProxies.LogonServiceClient.LogonServiceClientChannel.EndGetConfiguration(IAsyncResult result)
       at Microsoft.EnterpriseManagement.Presentation.Security.ServiceProxies.LogonServiceClient.Microsoft.EnterpriseManagement.Presentation.Security.ServiceProxies.ILogonService.EndGetConfiguration(IAsyncResult result)
       at Microsoft.EnterpriseManagement.Presentation.Security.ServiceProxies.LogonServiceClient.OnEndGetConfiguration(IAsyncResult result)
       at System.ServiceModel.ClientBase`1.OnAsyncCallCompleted(IAsyncResult result)
    I have uninstalled and reinstalled the web console.
    I cheked the pre-requisites, also configure permissions inheritance for the web console.
    Thanks in advance for any help.

    Hello,
    I have the same error as above when accessing the Web Console for our SCOM 2012 R2 environment - I have installed the web console on a standalone machine with mixed authentication - i have windows authentication enabled and NTLM is at the top of the providers
    list. I have gone through the process of registering the SPN's and configuring constraint delegation.
    I have followed the article below when performing the install:
    http://technet.microsoft.com/en-us/library/hh298606.aspx#bkmk_toconfigurepermissionsinheritanceforthewebconsole
    When we try to log into the Web Console remotely it appears to load to 100% but then brings up the error:
    An unexpected error has occured
    Please provide the following information to the support engineer if you have to contact Microsoft Help and Support :
    System.ServiceModel.CommunicationException: [HttpWebRequest_WebException_RemoteServer]
    Arguments: NotFound
    Debugging resource strings are unavailable. Often the key and arguments provide sufficient information to diagnose the problem. See http://go.microsoft.com/fwlink/?linkid=106663&Version=5.1.20913.0&File=System.Windows.dll&Key=HttpWebRequest_WebException_RemoteServer
    ---> System.Net.WebException: [HttpWebRequest_WebException_RemoteServer]
    Arguments: NotFound
    Debugging resource strings are unavailable. Often the key and arguments provide sufficient information to diagnose the problem. See http://go.microsoft.com/fwlink/?linkid=106663&Version=5.1.20913.0&File=System.Windows.dll&Key=HttpWebRequest_WebException_RemoteServer
    ---> System.Net.WebException: [HttpWebRequest_WebException_RemoteServer]
    Arguments: NotFound
    Debugging resource strings are unavailable. Often the key and arguments provide sufficient information to diagnose the problem. See http://go.microsoft.com/fwlink/?linkid=106663&Version=5.1.20913.0&File=System.Windows.dll&Key=HttpWebRequest_WebException_RemoteServer
       at System.Net.Browser.BrowserHttpWebRequest.InternalEndGetResponse(IAsyncResult asyncResult)
       at System.Net.Browser.BrowserHttpWebRequest.<>c__DisplayClassa.<EndGetResponse>b__9(Object sendState)
       at System.Net.Browser.AsyncHelper.<>c__DisplayClass4.<BeginOnUI>b__0(Object sendState)
       --- End of inner exception stack trace ---
       at System.Net.Browser.AsyncHelper.BeginOnUI(SendOrPostCallback beginMethod, Object state)
       at System.Net.Browser.BrowserHttpWebRequest.EndGetResponse(IAsyncResult asyncResult)
       at System.ServiceModel.Channels.HttpChannelFactory.HttpRequestChannel.HttpChannelAsyncRequest.CompleteGetResponse(IAsyncResult result)
       --- End of inner exception stack trace ---
       at System.ServiceModel.AsyncResult.End[TAsyncResult](IAsyncResult result)
       at System.ServiceModel.Channels.ServiceChannel.EndCall(String action, Object[] outs, IAsyncResult result)
       at System.ServiceModel.ClientBase`1.ChannelBase`1.EndInvoke(String methodName, Object[] args, IAsyncResult result)
       at Microsoft.EnterpriseManagement.Presentation.Security.ServiceProxies.LogonServiceClient.LogonServiceClientChannel.EndGetConfiguration(IAsyncResult result)
       at Microsoft.EnterpriseManagement.Presentation.Security.ServiceProxies.LogonServiceClient.Microsoft.EnterpriseManagement.Presentation.Security.ServiceProxies.ILogonService.EndGetConfiguration(IAsyncResult result)
       at Microsoft.EnterpriseManagement.Presentation.Security.ServiceProxies.LogonServiceClient.OnEndGetConfiguration(IAsyncResult result)
       at System.ServiceModel.ClientBase`1.OnAsyncCallCompleted(IAsyncResult result)

  • SCOM 2012 - ServiceNow connector - alert status "Forward Pending"

    Hi,
    Installed the connector available under here:
    http://www.servicenowguru.com/integration-tools/integration-update-sets/
    Steps followed: http://wiki.service-now.com/index.php?title=Microsoft_System_Center_Operations_Manager_SCOM_Integration
    However, the alert status is "Forward Pending". What can be the reason behind it?
    Anyone have the correct configuration steps for this connector? Following warning message logged every second in event viewer:
    Exception in timer function:No such host is known
    Any suggestions much appreciated!!

    For this issue, you can check below link
    http://social.technet.microsoft.com/Forums/systemcenter/en-US/e48cabab-b385-4156-84c1-f732a1285ccb/alert-forwarding-status-in-scom
    Please remember, if you see a post that helped you please click "Vote As Helpful" and if it answered your question, please click "Mark As Answer"
    Mai Ali | My blog: Technical | Twitter:
    Mai Ali

  • SCOM 2012 SP1 - Automating alert ownsership with command channel notification: the command keeps executing

    Hello everyone,
    here is the context: one of my client wants that, when a SCOM operator changes the resolution state of an alert to a specific resolution state "XYZ", the alert's ownership is automatically set to this user's AD Account.
    What I did:
    a PoSh script that takes the alert ID as a parameter, extracts the user ID from the alert's history - get-scomalerthistory - and sets the alert's owner field with this ID - set-scomalert -owner.
    a command channel running the script
    a subscription that triggers for alert with the specific resolution state "XYZ"
    It works great the first time - when the user sets the alert to XYZ state. Problems come right after this as it seems that modifying the alert in anyway - via GUI or script - will trigger the subscription once again.
    So, in fact, I need the subscription to trigger only when the alert CHANGES its resolution state to XYZ.
    Does anyone have an idea about this ?
    Reagrds,
    P. Augras

    Hi, it's predictable behavior as your script updates the alert property but alert property matches criteria specified. So one of methods is to change the resolution state in script to another state, something like XYZProcessed.

  • SCOM 2012 delay forwarding alerts to internal connector

    All,
    Is there anyway to delay alerts being forwarded to a connector similar to how you can with email subscriptions?
    I need to delay alerts being forwarded to AlertItNow connector until a powershell channel subscription has run.
    The powershell script populates Custom Field 1 which is required to run before the alert is forwarded to ServiceNow helpdesk.
    Thanks,
    Darren

    Hi Darren,
    I have to say that, as far as I know, no built-in way to delay forwarding to a connector.
    There is an option for delay aging for notifications configuration.
    http://blogs.technet.com/b/kevinholman/archive/2012/04/28/opsmgr-2012-configure-notifications.aspx
    Regards,
    Yan Li
    Regards, Yan Li

  • Installation of SCOM 2012 R2 with Orchestrator 2012 SP1 already installed

    I'm new here and found this set up.
    SCOM 2012 SP1 that was mis-installed badly. No DW, no Data Read or write account used. SPN's missing etc. Nothing is working on the SCOM Server. It's not connected to any other parts of System Center.
    Orchestrator 2012 SP1 installed and seems to be working fine.
    I know that I'm suppose to upgrade Orchestrator to R2 before upgrading SCOM 2012 to R2. But, I need to install SCOM 2012 R2 right now to ensure monitoring is in place. The question I have is can I install a fresh SCOM 2012 R2 and then go back and upgrade
    Orchestrator to R2 or do I have to upgrade Orchestrator 2012 to R2 before I install the new SCOM 2012 R2?

    Hi Bigredchief,
    Yes, it's recommended by Microsoft to update the Orchestrator first and then SCOM.
    Look at the diagram between SC components here:
    http://social.technet.microsoft.com/wiki/contents/articles/13188.system-center-2012-integration-guide.aspx
    and for Orchestrator here:
    http://social.technet.microsoft.com/wiki/contents/articles/13185.system-center-2012-integration-guide-orchestrator.aspx
    It’s clear visible from diagrams that SCOM monitors the Orchestrator by Management Pack and Orchestrator is connected to SCOM by Integration pack through Operations Manager SDK connection. The second link as well describes the integration between these 2
    components of SC (see #5.3).
    You should analyse your System Center components integration, and check if any Orchestrator runbooks communicate to SCOM. In general it will be 2 risk components in such upgrade (SCOM and then Orchestrator) in my opinion - not supported officially by MS
    in case of any issues, and stopped working SCOM connected runbooks.  
    Natalya

  • Automatic Maintenance Mode SCOM 2012

    What I'm trying to do is get an alert based on a shutdown event to trigger a script that then puts the server into maintenance mode.  I've seen a few solutions to this for 2007, but this is the only one I've seen for 2012. 
    https://overcast.azurewebsites.net/2013/11/auto-maintenance-mode-with-scom-2012/
    Basically, an alert is set up to watch for the shutdown event, which then uses a command channel to execute the script.  The main significant part of that is the use of the ManagedEntityDisplayName parameter in the command channel to pass the server
    name to the script.  If I run the script from a command prompt and pass the FQDN of the server to it as a parameter, it works like a charm.  But when I use SCOM to run it through the command channel, the server never gets put into
    mm.  For troubleshooting, I had it write a couple things to a log file. 
    When I run it from the command prompt, the log file contains the hostname I'm passing it for the ManagedEntity parameter in line 4, and the Instance that is returned from line 6 and it all works.
    When I run it with the command channel in SCOM, it again writes out the ManagedEntity parameter as the hostname, so that part seems to work the same.  But the Instance is returned to the log file as an empty line and then of course the server doesn't
    go into MM.  So it seems like something is different between me passing the FQDN as a parameter from the command line, and the command channel passing the ManagedEntity parameter from SCOM.  Even though they both get written to the log file as the
    hostname of the server.  Any idea what I'm missing?
    Param($ManagedEntityDisplayName)
    $startTime = [DateTime]::Now
    $endTime = $startTime.AddMinutes(15)
    "Managed Entity is $managedentitydisplayname" |out-file log.txt
    import-module OperationsManager
    $Instance = Get-SCOMClassInstance -Name $ManagedEntityDisplayName
    "Instance is $Instance" | Out-File log.txt -Append
    Start-SCOMMaintenanceMode -Instance $Instance -EndTime $endTime

    Hi 
    What version of Power shell are you using on your management server? The I suspect the issue might be that when you run it doesn't actually load "import-module
    OperationsManager" when scom runs it. So when you execute any scom command and save it into a variable it will always be empty.
    To test if this is the issue run this
    Param($ManagedEntityDisplayName)
    $startTime = [DateTime]::Now
    $endTime = $startTime.AddMinutes(15)
    "Managed Entity is $managedentitydisplayname" |out-file log.txt
    import-module OperationsManager
    $SCOMConnection = Get-SCOMManagementGroupConnection
    "Connection is $SCOMConnection" | Out-File log.txt -Append
    $SCOMAgent = Get-SCOMAgent -name $ManagedEntityDisplayName
    "SCOMAgent is $SCOMAgent" | Out-File log.txt -Append
    If you don't get anything for these variables looks like the Import module is the issue.
    I suggest the following:
    Adding the full file path location to the module (might just not be registered correctly)
    see: http://msdn.microsoft.com/en-us/library/dd878350(v=vs.85).aspx
    If the above doesn't fix the issue re installing the console might be needed
    see: http://thoughtsonopsmgr.blogspot.com.au/2013/02/om12-sp1-operations-manager-shell-fails.html
    What version of Power shell are you also running on your Management server/s? If you are running v4 you might also need to include credentials when making a connection to the management server:
    see: http://blogs.technet.com/b/robcost/archive/2008/05/01/powershell-tip-storing-and-using-password-credentials.aspx
    So your after you import the Operations manager module you need
    New-SCOMManagementGroupConnection -ComputerName "localhost" -Credential (Get-Credential WOODGROVE\Administrator)
    see: http://technet.microsoft.com/en-us/library/hh920188(v=sc.20).aspx
    Also how many management servers do you have? If you have more that 1 don't forget to place a copy of the script in the same location on each MS.
    Thanks Martin
    sustaslog.wordpress.com

  • Monitoring services on MSMQ cluster with SCOM 2012

    Hello guys,
    I'm looking a way that SCOM 2012 is able to monitor several services installed on MSMQ cluster. I think it's possible that SCOM 2012 can generate alert through the message queuing service associated to these services but this is an indirect monitoring. I
    would want that SCOM generates the alert for the specific service in problem.
    Any suggestion?
    Thank you very much.

    Hi,
    There is a management pack for ​Message Queuing.
    You can download it from http://www.microsoft.com/en-us/download/details.aspx?id=36775
    Hope it help's
    Greetings,
    Roel Knippen
    Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread.

  • SCOM 2012 SP1 Web Transaction Monitoring with Login test.

    Hi, 
    we setup a web transaction monitor test and did the full recording.  The web site is one that accepts an active directory account for login.  We also setup a runas account that is a valid account for the site and configured NTLM in the settings
    for authetication and set this runas account.
    The test does not fail.    However when we change the runas account password to force a failure, we dont get a failure on the website login test but instead a runas account verfication failure from SCOM.
    How can we configure the web transaction monitor to properly login during the test?   Any guidance would be appreciated.
    Thanks Lance

    So back to the original topic of the thread.
    We setup another test on a site that uses basic authentication.  We setup the web transaction test to use a  login on a initial site that transfers to a second site.  We recorded this entire test and saved.  It seems to work as it gives
    no errors.
    However when we change the Runas account's credentials, which means it CANT login to the site, it still runs fine with no errors.  
    This tells me it is not really logging in but just seeing the http status code is less than 400.
    What am I doing wrong.
    Thanks Lance

  • SCOM 2012 SP1 - PowerShell Script failed to run - 3 alerts appear after every reboot of the SCOM Server

    Brand new SCOM 2012 SP1 install with Update Rollup 1 applied
    Single server, local SQL install, SQL Server 2012 SP1
    Hyper-V VM running on Server 2012.  VM has 8GB Ram, single vCPU
    Going through initial management pack importing and configuration, at this point I have the Windows Server 2012 and SQL 2012 MP's installed.
    See screenshot
    http://i.imgur.com/l0Molh1.png
    I am getting the following alerts in my SCOM console and cannot find a resolution to fix the issue.  I don't want to set an override, as an override will prevent the PowerShell alert in other instances, where I might want to receive an alert.
    Looking at the alert description, it states "The Data Access service is either not running or not yet initialized"
    The SCOM Console launches and responds fine, and I get no other errors.  I check the Data Access service and it is online.  I have left the system alone for a couple of hours and no other errors.  I then closed those alerts and restarted the
    server, and they came right back in, so I know that this is something that is happening at either server startup of during the start of the SCOM services.
    Is it possible that SCOM is trying to execute these scripts and the Data Access service has not come online yet?
    Has anyone else come across this before?

    Please try the method in the following thread:
    Note: As there is operations related to Registry, please perform a backup before doing this.
    OpsMgr 2012 - Power Shell Script failed to run 
    http://social.technet.microsoft.com/Forums/de-DE/systemcenterde/thread/4be37f8d-1e7b-450c-8cb9-f1e95f3b2bd0/
    Thanks.
    Nicholas Li
    TechNet Community Support

  • SCOM 2012 monitoring IIS - windows updates generate SCOM alerts

    We are using SCOM 2012 to monitor our environment. There is a logic implemented to suppress alerts (using maintenance mode) when Windows Updates cause system reboot.
    We followed:<o:p></o:p>
    http://operatingquadrant.com/2009/08/15/scom-automatically-starting-maintenance-mode-when-servers-are-rebooted-for-patching/<o:p></o:p>
    Basically when in system event log event id 1074 appears then system is put in Maintenance mode. There is a problem with some IIS web servers - they
    generate a lot of alerts when Windows Updates are installed (e.g. Microsoft Windows Internet Information Services 2003 Application Pool is Unavailable)
    and before windows reboot. In details:
    5:08 AM - Windows update installation in event log (event id 19)e.g. 
    Installation Successful: Windows successfully installed the following update: Security Update for Microsoft .NET Framework 4 on Windows Server 2003, Vista, Windows 7, Server 2008 x86 (KB2972106)
    5:09 AM - SCOM generates alerts: Microsoft Windows Internet Information Services 2003 Application Pool is Unavailable
    5:17 AM - event id 1074: The process winlogon.exe has initiated the restart of computer. SCOM put this server in Maintenance mode.
    After 5:17 AM no more alerts generated by SCOM 
    We cannot change our logic and put system in maintenance mode based on event ID 19 (windows update installation) because there are a
    lot of event ID 19 events generated almost every day. So we do not want to put our server in maintenance mode each time when windows updates are installed. Just when windows update installation cause some IIS features stops. Any idea?

    For issue 1074, You can refer below link
    http://theitcrownd.blogspot.com/2012/01/set-up-automatatic-scom-maintenance.html
    Please remember, if you see a post that helped you please click "Vote As Helpful" and if it answered your question, please click "Mark As Answer"
    Mai Ali | My blog: Technical | Twitter:
    Mai Ali

  • Orchestrator/SCOM 2012 and UTC Time for Get Alert

    We are currently moving to using Orchestrator to act as a connector between SCOM 2012 and Unicenter for ticket generation.  Right now, the runbook that I have built out does the following.
    Monitor Date/Time > Format Date/Time > Get Alert
    The monitor Date/Time runs every 60 seconds.
    Format Date/Time then pulls from a variable that grabs the current time using now().  I then have it adding 4 hours and 55 minutes to the time to set the UTC time to 5 minutes earlier.
    Get Alert then looks for all alerts that meet a specific criteria.  This includes the time and any alert that was generated within the last 5 minutes, which is why I have it currently set to 4 hours and 55 minutes. 
    In a few months, that's going to break and I'll have to manually update the format date/time to 5 hours and 55 minutes.  What I'm trying to find is a way to do this automatically so the runbook doesn't have to be modified.  I'm thinking of using
    the 'Activity End Time in UTC' from the Monitor Date/Time but want to see if there's any other easier way of doing it.

    Hi again,
    If the question is to have a an easy way to get only Alerts not already seen with "Get Alert" before:
    Use "Update Alert" and update fields like TicketID or ResoultionState after "Get Alert" and exclude this criteria in the Filter tab of "Get Alert" ...
    Regards,
    Stefan
    www.sc-orchestrator.eu ,
    Blog sc-orchestrator.eu

Maybe you are looking for

  • Need help with BC4J/Struts application using a Stored Procedure

    Hi, I am doing a proof of concept for a new project using JDeveloper, Struts and BC4J. We want to reuse our Business logic that is currently residing in Oracle Stored Procedures. I previously created a BC4J Entity Object based on a stored procedure U

  • GPS in offline?

    If i use the phone (5800) in offline mode Can i use maps and GPS?

  • Problems with spacing in table(cs2, PC)

    Hi everyone I have imported a excell file into indesign cs2 (using place). When I mark the whole table I cannot change the height of the rows. I can choose at least or exactly however I cannot change the size, that box I gray. What am I doing wrong?

  • How to make in/out Port vis work with COM interface under different windows versions?

    Hello! I know that the accessHW is necessary for it, so I downlaoded the this file from the homepage of NI, but there are always some problems with it. My program should get the the voltage impulse between the pins DTR and RTS of a COM interface. Aft

  • ACS 4.2 with patch 4 Services restart

    I have installed ACS 4.2 with patch 4 Scertain period after authentication failed. Giving internal error. I need to restart all the services. What could be proble and pl help me in resolving this issue. I am running short of time.