Screen with table control which works like SM30

Hello,
I have a screen with some parameters in order to obtain some records from
a custom table. In the same screen I must insert a table control which
shows the extracted records.
This table control has to work exactly like transaction SM30, that is the
user can modify, insert, delete or copy a record.
Does anybody know if exists a way (or method) to include this transaction
in the table control ? Or I have to use custom control to obtain this ?
N.B. the user wants a screen with parameter and table control (or custom control)
and not a call function to transaction sm30.
I thank you in advance.                      Paolo.

Hi Rob,
thanks for your interest; no it's not a reason of authorization, but simply
the user wants to modify a report that actually works with some parameters
at the top of the screen and a customer control which shows an Alv_grid
with the extracted record;
Now the user needs to modify this records (insert and delete) directly from
this list. So I don't know if there's a way to obtain this goal without replace
the custom control with a table control.
The screen look like this:
   Param.1  XXXXXXX
   Param.2  XXXXXXXXXXXX
Custom Contr. with ALV_grid  (for extracted record)
                                                                         Regards.
                                                                         Paolo.

Similar Messages

  • ABAP HR How to create infotype with table control in it like Infotype 0008

    Hi Experts.
    I need help from u guys. My client requirement is to create custom infotype just like 0008 infotype which contain table control to save amount and wage types. I try to create infotype with table control using PM01, but that table control is in display mode only, i almost search every where to create custom infotype with table control but what ever threads in forum all are they unanswered and most of the threads for creating infotype. But i already done with infotype , but my main problem is table control.
    If any one have some suggestion for this please share with me.
    <removed by moderator> i am looking for positive reply.
    Edited by: Thomas Zloch on Aug 30, 2011 12:54 PM

    Hi
    I've created several infotypes with a Table Control and it is always the same story. You have to create a custom Z table to store the Table Control data (if you can have unlimited records), so in the PSXXXX structure you need to add a TABNR field to link the PAXXXX table and the Z one, just like the type table OM infotypes.
    Then in your code you have to control every possible operation, INS, MOD, DEL... and update the Z table accordingly (the standard code won't do that)
    If your TC fields appear in display mode, take a look at the Groups 1 and 3 in your fields, the must be set with the usual values for a PA infotype.
    If you have more questions, just ask,
    Regards

  • Error when displaying a field on Screen with Table Control

    Hi,
    It is going to 'Dump' when I am trying to display data on the screen with the help of Table Control. From the dump, What I have observed is , there is a field 'ZTSV_FSRDATA-ANZFEHLER'. If this field has negative value, then it is going to 'Dump' saying that the length is not enough. If it has a positive value then it is working fine. But the type of the field in the Internal table & on the screen are same.
    Please help me to resolve this error.
    I am posting here the Dump message also:
    A conversion error occurred while the program was trying todisplay data on the screen.
    The ABAP output field and the screen field may not have the same format.
    Some field types require more characters on the screen thanin the ABAP program. For example, a date field on a screen needstwo characters more than it would in the program. When attempting to display the date on the screen, an error will occur that triggers the error message.
    Thanks,
    Sreenivas Reddy Maddi.

    Hi Sreenivas,
       Refer this thread:
    how to display negative values in a screen field of a screen
    Re: negative values not allowed
    Regards,
    Sampath

  • Add Custom field to standard screen with table control

    Hello,
    I need to add two custom fields to a standard screen in CAT2 transaction(not using any screen exit).I will be given SSCR key.The standard screen (screen no. 2100) only has a table control.
    How can I add the custom field such that it appears as a field on the screen when CAT2 transaction is opened.
    Do i need to write any code?
    I'm new to ABAP so could you please give a detailed explanation.
    Also, do i need to change the 'fixed columns' field in the table control?
    Regards,
    Monica.

    hi,
    1) find the screen
    2) add new fields to the screen
    3) program PBO and PAI
    regards,
    Wojciech

  • Problem with Table control lines

    Hi Friends,
    This is the problem with table control lines:
    I have screen with table control and I would like change the table control lines dynamicaly.
    Exp:
    In my PBO the Internal table which I am using to loop the TC is havig 7 records and its displayed with 7 records, now I have added one more record into my ITAB and now ITAB is having 8 records, when I am looping this ITAB with TC its taking the TC lines 7 only.
    here is the code:
    Initial values in gt_scr400 = 8
    Initial values in tc_scr400 = 8
    Now added one more recor into gt_scr400 , now gt_scr400  = 9.
      LOOP AT   gt_scr400
           INTO wa_scr400
           WITH CONTROL tc_scr400
           CURSOR tc_scr400-current_line.
      ENDLOOP.
    I have used this logic :
      DESCRIBE TABLE gt_scr400 LINES g_rec_300 .
      tc_scr300-lines = g_rec_300.
    but its not modifying the lines in my table control.
    How to change the TC lines based on ITAB total records.
    Thanks,
    Sridhar

    there is a field in TableViewName-xxx
    don't remember the exact field name for (total no of records)
    you can check it in debug.  when you add records in Internal table, u need to modify this field which is set at the first time when table control is populated.

  • Screen enhancement with table control IW31, IW32, IW33.

    Hi Gurus,
    I am facing issues with enhancement implementation for Maintenance Orders transaction IW31, IW32, IW33. (SAP basis version 4.7)
    1) I have implemented enhancement IWO10018 for creating an Enhancement tab in transactions Iw31/ 32/ 33. This tab has got a table control which has 4 columns: -Operations, Operation short text, Estimated Cost and Currency Unit.
    First two fields are non editable and are populated for all the Operations in Operations tab. Last two columns are editable and value entered in these are stored in the database on saving. Now the issue is I am able to fetch all the operations from  AFVC table but these are the one which have been saved. Suppose I navigate between the tabs Operations and Enhancement and enter a new operation in Operations tab, I should get the same in my Enhancement tab table control field as well.
    Though we can obtain one value from structure (SAPLCOIH)AFVGD but this gives only one value. If we need to get the table of values, is their any option ???
    P.S. Assumption in this requirement was that there can be at max 50 operations in an order and 200 new fields are created for this in include CI_AUFK in table AUFK.
    2) In standard report transction IW39 to display the orders and operations, if we need to display additional columns for displaying Estimated Costs and Units per order, how do we need to implement enhancement IWOC0004. Do we need to add all custom fields in structure RIHAUFK_LIST as well. If you could please elaborate its implementation, it would be helpful.
    3) In standard report transaction IW49N, is there any enhancement available to add new fields in ALV display. (SAP basis version 4.7).
    I would be grateful if i can get a quick response as I am stuck in middle of something important.
    Edited by: shreya tagra on May 12, 2010 8:32 PM

    Hey All,
    To my questions further, I had found the runtime internal table where Operations are stored before saving.
    It is AFVGD_BT and its main program is SAPLCOBO. So it can be accessed through (SAPLCOBO)AFVGD_BT[].
    Also for 2 and 3 question, the given enhancement would work and we need to update fieldcatalog with custom fields.
    For this add our fields in RIHAUFK_LIST.
    Now, I am facing another issue. Since the enhancement tab is a subscreen, i am not able to get its okcodes. eg: When I click enhancement tab, sy-ucomm is 'CUK', when I scroll up or down again it is 'CUK', if I press enter again it is '+CUK'. To enable scrolling functions I need to get correct okcodes and differentitaed ones because on each user command, a different action is required. Any pointers how can this be achieved.
    Will post my solution once i m completly done with it. Till then your pointers are awaited..
    Thanks,
    Shreya

  • How can I work lsmw with table control using mm01 appl?

    Hi
    How can I work lsmw with table control using mm01 appl?
    Is it difefrent the way we handle table control in BDC?
    Thank You

    Hi
    How can I work lsmw with table control using mm01 appl?
    Is it difefrent the way we handle table control in BDC?
    Thank You

  • Customer Control in screen painter in Module pool - work like container?

    Customer Control option in screen painter in Module pool - work like container?
    is it true? How?
    Is like any work area or what?
    what is the excat use of that option?
    regards.

    Hello,
    In screen painter ,custom control is used to define the control area on the screen.Just click on that and make your own container area.When you create an ALV grid or TEXT EDITOR or any other control,it will get attached to the screen in that area through the custom container.
    Name the container area as say '<b>CONTAINER</b>'.(in capitals.)
    When you actually create the custom conatiner programatically,you should give the container area name.ie.
    Data : cont type ref to cl_gui_custom_container.
    Create object cont
    exporting
    parent = '<b>CONTAINER</b>'.
    Now,this container that you created-cont is attached to the screen in the area defined by CONTAINER.
    Regards,
    Beejal
    **Reward if this helps

  • How to handle the table control While working with LSMW?

    How to handle the table control While working with LSMW?

    its possible in lsmw,
    Hi,
    LSMW will have a Indicator for headr and itam, i do not remember the correct field, but it will have an indicator, check the fields, there will be a single charecter lenght field, that should be the indicator, and using that we can write the logic.
    check that single charecter field, it that is X that means the header record is processed, and do the items.
    and, this is another way, try this out also
    YOu can do this in "Define Source Structures" step,
    the HEADER is defined first,
    then the DETAIL below the HEADER.
    add the fields to the structures.
    Both should have some common key field
    Please take care that the name of the common field is the same.
    Once you do this it is linked. The you have a header and item corresponding to that header. then run the LSMW as you would.
    Thanks

  • Problem in SCROLLING  of TABLE CONTROL which is designed using WIZARD

    Hello Friends ,
                              I have designed a entry screen by using table control with wizard.  My table control layout  has 11 rows. I have used all 3 facilities i.e. SCROLLING , INSERT/DELETE  & SELECT/DESELECT by cheking ( ticking ) check boxes while designing table control with wizard.  
      Now i have 3 problems.
    1> In my entry screen , if 11 entries are entered , they are displayed in entry screen and are saved correctly in DB.
         But when  i copy a file of suppose 15 entries into entry screen then it displays only 11 entries in entry screen and after that  if  i click/move  VERTICAL SCROLL BAR to see remaining/next 4 entries  then it does not display  12th 13th 14th &15th entry in entry screen. So the problem is i am unable to display remaining/next 4 entries  in entry screen & also to save them DB.
    2>  At the same time when i click/move  VERTICAL SCROLL BAR to see remaining/next 4 entries  then  earlier 11 entries  are disappeared/ get cleared from entry screen.
    3> The FIRST PAGE, PREVIOUS PAGE , NEXT PAGE , LAST PAGE and INSERT , DELETE push buttons are dispalyed in my entry screen . But they are not working or doing their opertions on table control though there is system generated code for them written in module pool program and  PBO & PAI OF SCREEN 100 on which table control is present.
       So eagerly waiting for POSITIVE replies  &  Correct solutions from all ABAP techies.
    THANKS & REGARDS,
      Ashish.

    Hi friend,
                         I have visited the link u have given . But it is a report program .it is available in ABAPDOCU tcode.
    ABAPDOCU----
    >ABAP User Dialogs -
    >Screens -
    >Complex Screen Elements -
    >Table Control with Scrolling .
    It is a REPORT program. and not a module pool program. plz check this in ur link also.
    REPORT demo_dynpro_tabcont_loop.    &
    *SELECT * FROM spfli INTO CORRESPONDING FIELDS OF TABLE itab.* -
    > this statement is used only in report program and system does not allow us to use in module pool program.
    Second thing here data is retrived from spfli table where as my data will be whatever enduser enters it may be 15 lines , may be 50 lines or may be 200 lines and it shold be displayed on entry screen before clicking SAVE or any other user action.
    My main problem is that I am unable to enter more than 11 entries in my entry screen. I want dynaamic table. Mean whichever enteries are entered they should be displayed on entry screen as well as can be scrolled up & down before saving and get saved after clicking SAVE button. here table control design is not imp because entry data depends on table control layout rows & which has limit. It can not be extended beyond certain level. i think max will be 20 Or 25 rows in layout. How to make it dynamic so that we can get any no. of entries in entry screen hiich canbe scrolled up & down.
    Anyways thanks for ur reply And send some other soln.
    Thanks & regards,
    Ashish

  • Strange issue with table control in dialog programming! Please help!

    Hello everyone:
                I have a table control on screen painter and I have atleast 10 rows on display when user calls the screen. If I have 15 columns then ofcourse user has to scroll down to see extra rows. I have line selection set to "single" for table control so that user can select only one row at a time. This works fine when user does not have to scroll to see extra rows. It is tough for me to explain i.e., if the table control displays 10 rows when the screen opens up then they can only select single row at a time (rows 1 -10). For example user selected row 7 and now they scroll down to see extra rows (for example 13) then it lets them select row 13 also even though I set line selection to "single" in the properties for table control! They should be able to select only one row at a time. Is this some limitation with table control in SAP? Please give me any information you have.
    Thanks.
    Mithun

    Hi,
    As you suspected, this is a limitation in the table control.  You need to take care of the single-selection functionality yourself except for the rows that are actually being displayed.  See [Note 588284|https://service.sap.com/sap/support/notes/588284] for the official SAP explanation.
    Regards,
    Jamie

  • Sort up and sort Down push buttons in module pool with table control wizard

    hi,
    i have created 2 buttons for Sort up and sort Down push buttons in module pool with table control wizard
    please any one can help me.
    regards

    Hi
    Following code is to enable and disable the tbl control using two buttons. Just alter the code and for each button write the sort code.
    REPORT  YJAN27_SCREEN                                               .
    TABLES: SFLIGHT, YFLIGHT_28.
    TYPES: BEGIN OF struct1,
          carrid like sflight-carrid,
          connid like sflight-connid,
          fldate like sflight-fldate,
           END OF struct1.
    CONTROLS TBL1 TYPE TABLEVIEW USING SCREEN 2700.
    DATA: OK_CODE LIKE SY-UCOMM,
          CARRID LIKE SFLIGHT-CARRID,                                    "cols in tbl ctrl
          CONNID LIKE SFLIGHT-CONNID,
          FLDATE LIKE SFLIGHT-FLDATE,
          itab TYPE TABLE OF STRUCT1 WITH HEADER LINE,
          cols like line of TBL1-COLS,
          FLAG TYPE I.
    FLAG = 1.
    CALL SCREEN 2700.
    *&      Module  STATUS_2700  OUTPUT
    *       text
    MODULE STATUS_2700 OUTPUT.
      SET PF-STATUS 'BACK'.
    *  SET TITLEBAR 'xxx'.
    ENDMODULE.                 " STATUS_2700  OUTPUT
    *&      Module  USER_COMMAND_2700  INPUT
    *       text
    MODULE USER_COMMAND_2700 INPUT.
    OK_CODE = SY-UCOMM.
    CASE OK_CODE.
      WHEN 'BACK'.
        LEAVE PROGRAM.
      WHEN 'DIS'.                                                         "write code for sort up
        loop AT TBL1-COLS INTO COLS.
           COLS-SCREEN-INPUT = 0.
            MODIFY TBL1-COLS FROM COLS.
        ENDLOOP.
        FLAG = 2.
      WHEN 'ENA'.                                                       "write code for sort down
        loop AT TBL1-COLS INTO COLS.
            COLS-SCREEN-INPUT = 1.
            MODIFY TBL1-COLS FROM COLS.
        ENDLOOP.
        FLAG = 1.
    ENDCASE.
    ENDMODULE.                 " USER_COMMAND_2700  INPUT
    *&      Module  GET_DATA  OUTPUT
    *       text
    MODULE GET_DATA OUTPUT.
      select carrid connid fldate from SFLIGHT into table itab.
    ENDMODULE.                 " GET_DATA  OUTPUT
    *&      Module  POPULATE_TBL  OUTPUT
    *       text
    MODULE POPULATE_TBL OUTPUT.
        MOVE-CORRESPONDING ITAB TO SFLIGHT.
    ENDMODULE.                 " POPULATE_TBL  OUTPUT
    *&      Module  CHANGE_SCREEN  OUTPUT
    *       text
    MODULE CHANGE_SCREEN OUTPUT.    " use this module if you want to hide the other button
    CASE FLAG.
      WHEN 1.
        LOOP AT SCREEN.
          IF SCREEN-NAME = 'B_ENA'.
            SCREEN-INVISIBLE = 1.
             MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
        LOOP AT SCREEN.
          IF SCREEN-NAME = 'B_DIS'.
            SCREEN-INVISIBLE = 0.
             MODIFY SCREEN.
          ENDIF.
       ENDLOOP.
      WHEN 2.
        LOOP AT SCREEN.
          IF SCREEN-NAME = 'B_DIS'.
            SCREEN-INVISIBLE = 1.
            MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
        LOOP AT SCREEN.
          IF SCREEN-NAME = 'B_ENA'.
            SCREEN-INVISIBLE = 0.
             MODIFY SCREEN.
          ENDIF.
       ENDLOOP.
    ENDCASE.
    ENDMODULE.                 " CHANGE_SCREEN  OUTPUT
    PROCESS BEFORE OUTPUT.
    MODULE STATUS_2700.
    MODULE CHANGE_SCREEN.     " use this if you want to display one button at a time
    MODULE GET_DATA.
    loop at itab WITH control TBL1.
        MODULE POPULATE_TBL.       " populate tbl ctrl
    endloop.
    PROCESS AFTER INPUT.
    MODULE USER_COMMAND_2700.    " do the sort operations
    loop at itab.
      endloop.
    Hope this helps
    Regards,
    Jayanthi.K

  • How to create bdc with table control

    hi all.
    please some body tell me how to create bdc with table control
    or suggest any www with screen shots
    thanks in advance ,
    aparna

    Hi AParna,
    Its very Simple.
    ALl you have to do is set up a counter based on the number of lines in the tabke. when the counter reaches the number of lines in the table hit the next page button which is at the top of every screen in SAP.
    Please refer to the following BDC program I had developed using Table control,
    this is for ME01 transaction.
      LOOP AT T_EORD_HED.
        SELECT SINGLE * FROM MARA WHERE MATNR = T_EORD_HED-MATNR.
        IF SY-SUBRC = 0.
          PERFORM BDC_DYNPRO      USING 'SAPLMEOR' '0200'.
          PERFORM BDC_FIELD       USING 'BDC_CURSOR'
                                        'EORD-MATNR'.
          PERFORM BDC_FIELD       USING 'BDC_OKCODE'
                                        '/00'.
          PERFORM BDC_FIELD       USING 'EORD-MATNR'
                                        T_EORD_HED-MATNR.       "'58335'.
          PERFORM BDC_FIELD       USING 'EORD-WERKS'
                                        T_EORD_HED-WERKS.       "'0253'.
          L_COUNT = 1.
          LOOP AT T_EORD WHERE MATNR = T_EORD_HED-MATNR
                           AND WERKS = T_EORD_HED-WERKS.
            SELECT SINGLE * FROM LFA1 WHERE LIFNR = T_EORD-LIFNR.
            IF SY-SUBRC = 0.
    * Look into the if condition below
              IF L_COUNT = 010.
                L_COUNT = 1.
                PERFORM BDC_DYNPRO      USING 'SAPLMEOR' '0205'.
                PERFORM BDC_FIELD       USING 'BDC_CURSOR'
                                      'EORD-MATNR'.
                PERFORM BDC_FIELD       USING 'BDC_OKCODE'
                                       '=NS'.
                L_COUNT = L_COUNT + 1.
              ENDIF.
              PERFORM BDC_DYNPRO      USING 'SAPLMEOR' '0205'.
              PERFORM BDC_FIELD       USING 'BDC_CURSOR'
                                            'EORD-AUTET(01)'.
              PERFORM BDC_FIELD       USING 'BDC_OKCODE'
                                            '/00'.
              CONCATENATE 'EORD-VDATU' '(' L_COUNT ')' INTO OPR_FIELD.
              WRITE SY-DATUM TO T_EORD-VDATU.
              PERFORM BDC_FIELD       USING OPR_FIELD
                                            T_EORD-VDATU.
              CONCATENATE 'EORD-BDATU' '(' L_COUNT ')' INTO OPR_FIELD.
              WRITE T_EORD-BDATU TO V_BDATU.
              PERFORM BDC_FIELD       USING OPR_FIELD
                                            V_BDATU.
              CONCATENATE 'EORD-LIFNR' '(' L_COUNT ')' INTO OPR_FIELD.
              PERFORM BDC_FIELD       USING OPR_FIELD
                                            T_EORD-LIFNR.
              CONCATENATE 'EORD-EKORG' '(' L_COUNT ')' INTO OPR_FIELD.
              PERFORM BDC_FIELD       USING OPR_FIELD
                                            '0001'.
              CONCATENATE 'EORD-RESWK' '(' L_COUNT ')' INTO OPR_FIELD.
              PERFORM BDC_FIELD       USING OPR_FIELD
                                            T_EORD-RESWK.
              WRITE T_EORD-MEINS TO V_MEINS.
              CONCATENATE 'EORD-MEINS' '(' L_COUNT ')' INTO OPR_FIELD.
              PERFORM BDC_FIELD       USING OPR_FIELD
                                            V_MEINS.
    *          CONCATENATE 'EORD-EBELN' '(' L_COUNT ')' INTO OPR_FIELD.
    *          PERFORM BDC_FIELD       USING 'OPR_FIELD'
    *                                        T_EORD-EBELN.
              CONCATENATE 'EORD-EBELP' '(' L_COUNT ')' INTO OPR_FIELD.
              PERFORM BDC_FIELD       USING OPR_FIELD
                                            T_EORD-EBELP.
              IF T_EORD-FLIFN NE SPACE OR T_EORD-FRESW NE SPACE OR
                 T_EORD-FEBEL NE SPACE.
                CONCATENATE 'RM06W-FESKZ' '(' L_COUNT ')' INTO OPR1_FIELD.
                PERFORM BDC_FIELD       USING OPR1_FIELD
                                              'X'.
              ENDIF.
              IF T_EORD-NOTKZ <> ''.
                CONCATENATE 'EORD-NOTKZ' '(' L_COUNT ')' INTO OPR_FIELD.
                PERFORM BDC_FIELD       USING OPR_FIELD
                                              'X'.
              ENDIF.
              CONCATENATE 'EORD-AUTET' '(' L_COUNT ')' INTO OPR_FIELD.
              PERFORM BDC_FIELD       USING OPR_FIELD
                                            T_EORD-AUTET.
              L_COUNT = L_COUNT + 1.
            ENDIF.
          ENDLOOP.
          PERFORM BDC_FIELD       USING 'BDC_CURSOR'
                                        'EORD-MATNR'.
          PERFORM BDC_FIELD       USING 'BDC_OKCODE'
                                        '=BU'.
          CALL TRANSACTION 'ME01' USING I_BDCDATA
                        MODE UP_MODE
    *                     optIONS  FROM l_opt
                        MESSAGES INTO I_BDCMSGCOLL.
          PERFORM FORMAT_OUTPUT.
        ENDIF.
      ENDLOOP.

  • Last night I did an update and now when I turn on my macbook it just goes to the white screen with the apple and stays like that.

    Last night I did an update and now when I turn on my macbook it just goes to the white screen with the apple and stays like that. How do I fix this issue?

    Take each of these steps that you haven't already tried. Stop when the problem is resolved.
    To restart an unresponsive computer, press and hold the power button for a few seconds until the power shuts off, then release, wait a few more seconds, and press it again briefly.
    Step 1
    The first step in dealing with a startup failure is to secure the data. If you want to preserve the contents of the startup drive, and you don't already have at least one current backup, you must try to back up now, before you do anything else. It may or may not be possible. If you don't care about the data that has changed since the last backup, you can skip this step.
    There are several ways to back up a Mac that is unable to start. You need an external hard drive to hold the backup data.
    a. Start up from the Recovery partition, or from a local Time Machine backup volume (option key at startup.) When the OS X Utilities screen appears, launch Disk Utility and follow the instructions in this support article, under “Instructions for backing up to an external hard disk via Disk Utility.” The article refers to starting up from a DVD, but the procedure in Recovery mode is the same. You don't need a DVD if you're running OS X 10.7 or later.
    b. If Step 1a fails because of disk errors, and no other Mac is available, then you may be able to salvage some of your files by copying them in the Finder. If you already have an external drive with OS X installed, start up from it. Otherwise, if you have Internet access, follow the instructions on this page to prepare the external drive and install OS X on it. You'll use the Recovery installer, rather than downloading it from the App Store.
    c. If you have access to a working Mac, and both it and the non-working Mac have FireWire or Thunderbolt ports, start the non-working Mac in target disk mode. Use the working Mac to copy the data to another drive. This technique won't work with USB, Ethernet, Wi-Fi, or Bluetooth.
    d. If the internal drive of the non-working Mac is user-replaceable, remove it and mount it in an external enclosure or drive dock. Use another Mac to copy the data.
    Step 2
    If the startup process stops at a blank gray screen with no Apple logo or spinning "daisy wheel," then the startup volume may be full. If you had previously seen warnings of low disk space, this is almost certainly the case. You might be able to start up in safe mode even though you can't start up normally. Otherwise, start up from an external drive, or else use the technique in Step 1b, 1c, or 1d to mount the internal drive and delete some files. According to Apple documentation, you need at least 9 GB of available space on the startup volume (as shown in the Finder Info window) for normal operation.
    Step 3
    Sometimes a startup failure can be resolved by resetting the NVRAM.
    Step 4
    If a desktop Mac hangs at a plain gray screen with a movable cursor, the keyboard may not be recognized. Press and hold the button on the side of an Apple wireless keyboard to make it discoverable. If need be, replace or recharge the batteries. If you're using a USB keyboard connected to a hub, connect it to a built-in port.
    Step 5
    If there's a built-in optical drive, a disc may be stuck in it. Follow these instructions to eject it.
    Step 6
    Press and hold the power button until the power shuts off. Disconnect all wired peripherals except those needed to start up, and remove all aftermarket expansion cards. Use a different keyboard and/or mouse, if those devices are wired. If you can start up now, one of the devices you disconnected, or a combination of them, is causing the problem. Finding out which one is a process of elimination.
    Step 7
    If you've started from an external storage device, make sure that the internal startup volume is selected in the Startup Disk pane of System Preferences.
    Start up in safe mode. Note: If FileVault is enabled in OS X 10.9 or earlier, or if a firmware password is set, or if the startup volume is a software RAID, you can’t do this. Post for further instructions.
    Safe mode is much slower to start and run than normal, and some things won’t work at all, including wireless networking on certain Macs.
    The login screen appears even if you usually log in automatically. You must know the login password in order to log in. If you’ve forgotten the password, you will need to reset it before you begin.
    When you start up in safe mode, it's normal to see a dark gray progress bar on a light gray background. If the progress bar gets stuck for more than a few minutes, or if the system shuts down automatically while the progress bar is displayed, the startup volume is corrupt and the drive is probably malfunctioning. In that case, go to Step 11. If you ever have another problem with the drive, replace it immediately.
    If you can start and log in in safe mode, empty the Trash, and then open the Finder Info window on the startup volume ("Macintosh HD," unless you gave it a different name.) Check that you have at least 9 GB of available space, as shown in the window. If you don't, copy as many files as necessary to another volume (not another folder on the same volume) and delete the originals. Deletion isn't complete until you empty the Trash again. Do this until the available space is more than 9 GB. Then restart as usual (i.e., not in safe mode.)
    If the startup process hangs again, the problem is likely caused by a third-party system modification that you installed. Post for further instructions.
    Step 8
    Launch Disk Utility in Recovery mode (see Step 1.) Select the startup volume, then run Repair Disk. If any problems are found, repeat until clear. If Disk Utility reports that the volume can't be repaired, the drive has malfunctioned and should be replaced. You might choose to tolerate one such malfunction in the life of the drive. In that case, erase the volume and restore from a backup. If the same thing ever happens again, replace the drive immediately.
    This is one of the rare situations in which you should also run Repair Permissions, ignoring the false warnings it may produce. Look for the line "Permissions repair complete" at the end of the output. Then restart as usual.
    Step 9
    If the startup device is an aftermarket SSD, it may need a firmware update and/or a forced "garbage collection." Instructions for doing this with a Crucial-branded SSD were posted here. Some of those instructions may apply to other brands of SSD, but you should check with the vendor's tech support.  
    Step 10
    Reinstall the OS. If the Mac was upgraded from an older version of OS X, you’ll need the Apple ID and password you used to upgrade.
    Step 11
    Do as in Step 9, but this time erase the startup volume in Disk Utility before installing. The system should automatically restart into the Setup Assistant. Follow the prompts to transfer the data from a Time Machine or other backup.
    Step 12
    This step applies only to models that have a logic-board ("PRAM") battery: all Mac Pro's and some others (not current models.) Both desktop and portable Macs used to have such a battery. The logic-board battery, if there is one, is separate from the main battery of a portable. A dead logic-board battery can cause a startup failure. Typically the failure will be preceded by loss of the settings for the startup disk and system clock. See the user manual for replacement instructions. You may have to take the machine to a service provider to have the battery replaced.
    Step 13
    If you get this far, you're probably dealing with a hardware fault. Make a "Genius" appointment at an Apple Store, or go to another authorized service provider.

  • HT4085 how to lock the tauch screen with some password or dots like android to prevent misuse. And also screen lock to prevent interruption while watching movie reading books etc.

    how to lock the tauch screen with some password or dots like android to prevent misuse. And also screen lock to prevent interruption while watching movie reading books etc.

    You can set a passcode to be requied to unlock the iPad via Settings > General > Passcode Lock. In terms of locking the actual screen whilst using an app, then that isn't currently possible, but with iOS 6 in the Autumn there will be a new 'accessibility' feature (from here) which will allow you :
    ... to limit an iOS device to one app by disabling the Home button, as well as restrict touch input on certain areas of the screen

Maybe you are looking for

  • CS 6 lässt sich nicht mehr installieren.

    Hallo, habe vor kurzem große Probleme mit meinem Betriebssystem gehabt. Deswegen habe ich sämtliche Software von meinem Laptop entfernt. Unter anderem auch CS 6 und sämtliche Adobe-Produkte. Darauf hin habe ich auch das Adobe Creative Cloud Cleaner T

  • What 32inch plus tv to buy in the UK to use with new intel Mac mini

    As the title - What 32inch plus tv to buy in the UK to use with 1.83 intel Mac mini. It does not have to have freeview as I will be using tubestick. I do want to use the hdmi connection. Who's got a great setup, with no issues - model numbers appreci

  • Cash Discount taken after overdue

    Hi, I am a supplier to an SAP customer. Our Terms are  2% net 31, from receipt of the product. They 'always' take the 2% discount, though often they write the check in 32-35 days (the weekends are not the reason for the delay, as they receive usually

  • Maximize Purchase Order -- Error -- Its Urgent!!!!

    Hai To All,               Iam customizing Purchase Order Form. There iam adding one button near cancel button. If i maximum purchase order form i got the following error and SAP Application is closed. The instruction at "0x77fcb333" referenced memory

  • YouTube's H.264 isn't Working?

    I've noticed that ClickToFlash isn't loading H.264 video anymore from YouTube. In addition, iTubeX (which is a download from YouTube program) is downloading a 0KB FLV file more often then not, whereas a few weeks ago it was downloading an MPEG-4 file