Searching non-key fields in table maintainance

Hi..
How to find non-key fields or how can we enble the FIND button in maintaince table ?
Please reply....
Thanks ...

Hi,
When you are on the table maintenance screen, you can :
1. Goto menu options. Selection-->By Content
2. Choose the fields you want to search data on and Press enter
3. Enter the operator and the value  (you can append or insert a new field here as well )
4. Click on the choose button.
regards,
Advait

Similar Messages

  • How to Set Position Cursor Option to Non key fields in Table Maintenance .

    Hi,
    I have created a Ztable and i am using table maintenance for that table. In TMG ,by default  we have position cursor option to key fields only . User wants that position cursor option for non key fields also. Please help me out of this issue .
    How to provide Position Cursor option to Non key fields.
    Thanks & Regards,
    Prasad.

    Hi Nabheet,
    I tried using TYPE S DISPLAY LIKE E and am setting vim_abort_saving as X and sy-subrc as 4. However, this is also not enabling the fields. In this case, the first 2 fields - key fields are getting enabled but not the required ones. The above snapshot is for the same.
    lv_date1 = table1-date1.
       lv_date2 = table1-date2.
       lv_diff = lv_date2 - lv_date1.
       IF lv_diff LT 0.
         CLEAR: lv_err_msg.
         lv_err_msg = text-005.
         MESSAGE lv_err_msg TYPE 'S' DISPLAY LIKE  lc_e.
         vim_abort_saving = lc_x.
         sy-subrc = 4.

  • Validating non key fields in table maintenance generator

    Hi,
    I ma using events for table maintenance generator event 05 ,there i want to validate non key fields ......i am throwing error message ....all the non key fields are getting in display mode ...i need them to enable to enter values ....
    please suggest
    Thanks,
    Shailaja Ainala.

    Hi Shailaja,
    Its property of error message, which makes it as non-editable.
    You can display either status or info message after validation check.
    And finally before saving (before save event) display error message, so that it invalid entries doesnt get saved.
    Thanks,
    Nisha Vengal.

  • Non key field in Maintainance View

    Hi,
    I have generated a maintainance view for a Z table. I want to sort data from SM30 by means of a selection screen, for that, in the 'View Flds' tab in the maintainance view, i have entered a 'S' for which ever fields i want to filter the data on.
    When i execute the table maintainance, i am able to see only the key fields and not the non-key ones in the selection popup, though i have put a 'S' for both, the key and non-key fields.
    Can anyone please let me know how to get the non-key fields on the selection popup when i execute the maintainance view?
    Cheers,
    Raghav.

    Not possible via this functionality. A workaround was suggested by Raymond in this thread:
    Transaction code for Table Maitainence for table
    Thomas

  • Key fields and non-key field of condition table

    Hello Gurus,
          what is key fields and non-key field of condition table?
    thanks very much!

    Key field
    Each condition table contains keys that can be used for creating dependent condition records.
    for example let take condition type PR00.
    PR00 uses access sequence PR02 .
    Access sequence PR02 has following tables associated with it namely 304, 305 & 306
    When you create a conditon record for PR00 with transaction VK11 or VK31, you have a button 'key combination' which is nothing but fields associated with tables 304, 305 & 306.
    In brief, Condition records are always created using specific keys. Condition tables are used to define the structure of the keys of a condition record.
    Non key field
    For example take condition table 144 - sales deal basic data.
    Table 144 is associated with access sequence PBUD.
    If you check the fields associated with this table (click technical view button), there are three fields at bottom which do not have 'key' check mark -KDATU, PLTYP, KSTAF
    So, when you create a condition record for PBUD, system does not propose these 3 fields in 'key combination' and hence are non key fields.
    Please reward points for good answers as this would help increase the total donation that SAP will make to the United Nations World Food Programme.

  • Changing Non key field to Key field in a custom table

    Hello Abap gurus:
    I have a requirement in which i need to change a non key field in my custom table(Z TABLE) to key field.
    For example; i have field sequence as
    field 1  key field
    field 2 key field
    field 3 key field
    field 4 non-key field
    field 5 non-key field
    field 6 non-key field
    field 7 non-key field.
    i want to change field 7 as key field.
    Can i do perform operation??
    when i am tryingto perform bove operation it is taking long time to get the table activated.
    Could any one please help me in getting this resolved.
    regards,
    Sravanthi.

    Use DB Utility (se14) to perform alter table or conversion. The latter is used when atemps to perform first operation fails. Which one is used, really depends on system and current DB table state (i.e. if has any content and what is being adjusted).
    The way Max suggested is similar to [conversion process|http://help.sap.com/saphelp_nw04/helpdata/EN/cf/21f1b8446011d189700000e8322d00/content.htm] which system takes care of itself.
    Refer [Adjusting Database Structures|http://help.sap.com/saphelp_nw04/helpdata/EN/cf/21f1ab446011d189700000e8322d00/content.htm] and already given link to conversion.
    Please also consider potential errors while doing conversion . This can lead to data loss, so you should think of some backup to prevent that.
    Regards
    Marcin

  • It is possible to assign value range to non key fields in the table?

    Hi,
    I want to give some range of values to the fields which are non key fields in the table.
    is it possible?
    can anybody tell me the procedure.
    Thanks in Advance,
    venkat

    HI,
    It is higjly possible in case of Z-table. but in standard table you can't make any modification.
    You assign the value range to the domain of field.
    go to SE11 and open the database table.
    Select the Data Element of the fieldto which  you want assign the range.
    Click on its domain .
    click on Value Range tab.
    Set the range.
    Regards,
    anirban

  • How can we hide the non key field values in the sm30 display

    hello experts,
    I have to protect the non key field values in the sm30 display , can u help me out wat changes i have to do in the layout.

    Hello Gopal,
    What do you mean by 'protecting' your non-key field value?
    1) You want to display it, but make it non-changeable
    A - Make the field as output-only in screen, as already answered by a preivous collegue
    2) You do not want to display this field at all
    A - Goto the DDIC definition of the view (not possible for a table directly), and maintain the required field as a Hidden. After activating, remember to re-generate the maintenance dialogue. Also, please maintain Event 21, in case you want to access/change the value of this field in background.
    3) You want to maintain special validations/checks for the field
    This can be easily done by introducing your modules within the CHAIN-FIELD commands in the PAI of the generated screens.
    Best Regards,
    Rekha

  • Error in collect statement(non-key fields must be numeric)...

    Error in collect statement(non-key fields must be numeric)...
    Hello Experts,
    I created an internal table based from a ztable. The structure of the ztable is
    as follows:
    1. MANDT -> PRIMARY KEY
    2. BUKRS -> PRIMARY KEY
    3. TXK50 -> PRIMARY KEY
    4. ANLKL -> PRIMARY KEY
    5. KTANSW -> PRIMARY KEY
    6. KOSTL  -> PRIMARY KEY
    Then the remainder of the fields(around 8 fields) are currency data types(ANBTR).
    An error is showing saying 'You can only use the collect command in a table if all of its non-key
    fields are numeric(type I,P or F).
    I searched the forum and it said that non-keys must be numeric in order for the
    collect command to work. But all of my primary keys are non-numeric.
    Below is my declaration:
    CLASS-DATA: gt_output_acq TYPE hashed TABLE OF zsd_output_acq
                                  WITH UNIQUE KEY bukrs txk50 anlkl
                                                  ktansw kostl,
                    gt_output_ret LIKE gt_output_acq,
                    wa_output_gen LIKE LINE OF gt_output_acq,
                    gt_output_net TYPE HASHED TABLE OF zsd_output_net
                                  WITH UNIQUE KEY bukrs txk50 anlkl
                                                  ktansw kostl,
                    wa_output_net LIKE LINE OF gt_output_net,
                    gt_sort_crit  TYPE SORTED TABLE OF t_sort_crit
                                  WITH NON-UNIQUE KEY bukrs kostl,
                    wa_sort_crit  LIKE LINE OF gt_sort_crit.
    FIELD-SYMBOLS: <fs_output_acq> LIKE LINE OF gt_output_acq,
                       <fs_output_ret> LIKE LINE OF gt_output_ret,
                       <fs_output_net> LIKE LINE OF gt_output_net.
    COLLECT <fs_output_acq> INTO gt_output_acq.     "Here is the error

    Hi Vijay,
    Here it is:
    CLASS-DATA: gt_output_acq TYPE hashed TABLE OF zsd_output_acq
                                  WITH unique KEY bukrs txk50 anlkl
                                                  ktansw kostl,
                    gt_output_ret LIKE gt_output_acq,
                    wa_output_gen LIKE LINE OF gt_output_acq,
                    gt_output_net TYPE hashed TABLE OF zsd_output_net
                                  WITH unique KEY bukrs txk50 anlkl
                                                  ktansw kostl,
                    wa_output_net LIKE LINE OF gt_output_net,
                    gt_sort_crit  TYPE SORTED TABLE OF t_sort_crit
                                  WITH NON-UNIQUE KEY bukrs kostl,
                    wa_sort_crit  LIKE LINE OF gt_sort_crit.

  • How can we protect the  ztable non key fields data in sm30 display.

    Hi experts,
         I have created tablemaintenence generator for one z table, in sm30 user has access to enter the data.
    in that maintenence i have to protect the non key field values data  like once the user saves his data.than in the edit mode it has to show the nonkey fields data  but  dont access to edit some nonkey fields... please help

    Hi
    U need to change the screen flow generated by maintenance view generator: here go to Enviroments->Modifications->Screen; doubleclick on your screen and the system take you to screen painter.
    Here go to screen flow and in PBO add new module in order to protect the field for the old records: u can use the statament LOOP AT SCREEN./ENDLOOP to do it.
    LOOP AT SCREEN.
       IF .....
         SCREEN-INPUT = 0.
         MODIFY SCREEN.
       ENDIF.
    ENDLOOP.
    Max

  • Old key field FROMNUMBER is now non-key field

    Hi All,
    I am getting one issue with NRIV table.When I tried to activate this table from se11 it is giving error as
      Program start============================================================
      Mass activation
      =========================================================================
      Process..................: presap_4
      User.....................: ABAP1
      Date, time...............: 19.02.2007, 12:50:33
      Platform.................: CUSTOMER-PRE(620)/ORACLE/WindowsNT/presap
      Tool.....................: SE11_OLD/RADMASG0
      Log......................: T, ABAP120070219125033
      Program parameters:
      Input medium..............: Direct object entry
      Activation method.........: Activ
      Chk. mode.................: O
      Version to be activated...: M
      Versions to Be Deleted....: Delete only active versions
      Lock against paral. exec..: Shared
      Parallel mode.............: Switched off
      =========================================================================
      Start phase 001 **********************************************************
            Activation of objects
    Activate objects at level 1
        Old key field FROMNUMBER is now non-key field
      Structure change at field level (convert table NRIV)
            Activation of objects
      End phase  001 ***********************************************************
               Activation of objects
    Activate objects at level 1
           Old key field FROMNUMBER is now non-key field
         Structure change at field level (convert table NRIV)
               Activation of objects
         End phase  001 ***********************************************************
         Start phase 002 **********************************************************
               Final log
         Following objects not activated/deleted or activated/deleted w. warning:
         Table NRIV could not be activated
         (E- Structure change at field level (convert table NRIV) )
           Final log
    End phase  002 ***********************************************************
    Start phase 003 **********************************************************
           Statistics on activated and deleted objects
    Number of objects to be activated............:  1
    Objects not activated........................:  1
    Activated objects with errors in dependencies:  0
    Objects activated with warning...............:  0
    Successfully activated objects...............:  0"
    Can any one help in this.It is bit urgent.
    Thanks,
    Krishna

    Hi Brend,
    Thanks for the reply.
    But could you tell me how to convert this table and what to convert.
    Posibble could you give this with step by step, we are struck with number range issues with this problem and needed with critical.
    Thanks for the help in advance.
    Krishna

  • To pass non key field data to workflow

    Hello,
    I want to pass data from webdynpro application to workflow. For this i used FM 'SWE_CREATE_EVENT' to trigger the workflow.
    I filled the container table with following values
    wa_cont-element = 'NAME2'
    wa_cont-value = 'James Anderson'.
    APPEND wa_cont to it_cont.
    wa_cont-element = 'STRAS'
    wa_cont-value = 'Hampshire'.
    APPEND wa_cont to it_cont.
    wa_cont-element = 'PSTLZ'
    wa_cont-value = '104010'.
    APPEND wa_cont to it_cont.
    wa_cont-element = 'ORT01'
    wa_cont-value = 'London'.
    APPEND wa_cont to it_cont.
    wa_cont-element = 'LAND1'
    wa_cont-value = 'United Kingdom'.
    APPEND wa_cont to it_cont.
    Also i created a custom business object 'ZHRADCHO'. In which i decleared
    KEY FIELDS as ->
    PERNR
    SUBTY
    ENDDA
    BEGDA
    METHODS ->
    send_data_to_wf
    I created Import/Export parameters for this method ->
    NAME2 (Import and Export parameter)
    STRAS (Import and Export parameter)
    PSTLZ (Import and Export parameter)
    ORT01 (Import and Export parameter)
    LAND1 (Import and Export parameter)
    EVENTS ->
    CHANGE
    In SWDD transaction -> basic data -> binding
    I did the following binding
    &_EVT_CREATOR&                             =>     &_WF_INITIATOR&
    &_EVT_OBJECT.PERSONNELNUMBER&        =>     &WA_ZHRAD.PERNR&
    &_EVT_OBJECT.SUBTYPE&        =>               &WA_ZHRAD.SUBTY&
    &_EVT_OBJECT.ENDDATE&        =>     &WA_ZHRAD.ENDDA&
    &_EVT_OBJECT.STARTDATE&        =>     &WA_ZHRAD.BEGDA&
    WA_ZHRAD is structure type of custom table ZHRAD in which i want the data. So in the workflow container i created the element of type ZHRAD. How do i get the rest of the fields which i declared in the method. I am able to get the data in the key fields which are binded as above. But if i bind the rest of the fields i get an error. How do i get the data in non-key field elements?
    Regards,
    Yayati Ekbote

    Hello Rick,
    I am passing the other values through container only. But my question is, in workflow side, in which parameters will i recieve the values?
    In the method of the BO i wrote in the automatically generated program.
    swc_get_element container  'C/o ' CO.
    swc_set_element container  'C/o ' CO.
    swc_get_element container  'StreetHouseNo '  STREETHOUSENO.
    swc_set_element container  'StreetHouseNo ' STREETHOUSENO.
    Like wise for all non-key parameters.
    So in SWDD transaction, which parameters should i bind to get the values in the fields of workflow container?
    Regards,
    Yayati Ekbote

  • INFNR - Non-key field

    Hi SAP Lords,
    I need table where INFNR should be a non-key field.
    I have MATNR, WERKS, VKORG,LIFNR,EKORG in hand but just cant find the table to extract INFNR.

    EBAN                             Purchase Requisition
       EINA                             Purchasing Info Record: General Data
       EINE                             Purchasing Info Record: Purchasing Organization Data
       EIPA                             Order Price History: Info Record
       EKPO                             Purchasing Document Item
       ELBM                             Vendor Evaluation: Material-Related Item
    Nabheet

  • How many key fields can we maintained in dso or ods

    HI
    pls let me know how many key fields can we maintained in DSO or ODS.
    Thanks and Regards.
    ASIM.

    Hi,
    Key fields can only be 16 you cannot exceed this. but if you have more key fields, you can combine fields using a routine for a key field
    Max Data Fields - 749 data fields can be added in a DSO.
    Regards,
    Marasa.

  • How to update key fields for table

    Hi,
    how to update key fields for a table.The update statement is not working for the same.
    Regards,

    Hi,
    See the below example.
    TABLES SPFLI.
    DATA WA TYPE SPFLI.
    MOVE 'AA' TO WA-CARRID.
    MOVE '0064' TO WA-CONNID.
    MOVE 'WASHINGTON' TO WA-CITYFROM.
    UPDATE SPFLI FROM WA.
    MOVE 'LH' TO SPFLI-CARRID.
    MOVE '0017' TO SPFLI-CONNID.
    MOVE 'BERLIN' TO SPFLI-CITYFROM.
    UPDATE SPFLI.
    CARRID and CONNID are the primary key fields of table SPFLI. All fields of those lines where the primary key fields are "AA" and "0064", or "LH" and "0017", are replaced by the values in the corresponding fields of the work area WA or the table work area SPFLI.
    Regards,
    raj.

Maybe you are looking for

  • Additional results doesn't work with multi-line string dat

    I observed an erratic behavior with "Additional Results" in TestStand 2010. The problem statement is as follows: 1. I have a variable "Locals.FirstName" 2. I have another variable "Locals.LastName" 3. Concatenate these two strings with a line feed or

  • Office 2013 Professional Plus configures each time you start

    I have a problem that has been well documented for Office 2010. I have just installed Office 2013 as an upgrade from Office 2010 and every time I open an Office 2013 application I get the following message: 'Please wait while windows configures Micro

  • Listing of error messages?  can't burn CD

    All of a sudden i can't burn a CD off of my itunes playlist. It says error code 4550, or 4500, can't remember which one. It worked just fine last week. I'm a fitness instructor and burn CD's several times a week for my classes. I need this fixed. Ple

  • Where is System Pref to disable Quad Cores?

    I cannot find the Processor System Preference that lets you enable or disable the processor cores on the Quad. Where can this be found? I read an article that states they can disable the cores, but cannot find where?

  • Reader 9 & X will not install

    I am getting the below errors when trying to install Adobe Reader.  Either 9 or X.  It is also the same dll file that crashes IE9 randomly also. I have run malwarebytes, Symantec, Hijackthis, TDDSKiller, GMER and I have no idea what is going on. I ca