SeeBurger Adapter PostInstallation

Hi guys,
I'm back with another cool doubt...
We're using SeeBurger AS2 Adapter and we've followed every installation step described in the corresponding manuals.
I'd like to try a short example, sending a test message to a partner just to check if the installation is working properly. However, I've bumped at the point when I was creating the sender communication channel. When trying to select the AS2 Adapter, there's no signal of it. I can only get all the SAP BASIS Adapters (RFC, Idoc, etc...) list displayed, no signal of AS2.
So I thought, let me check if the corresponding SWCV is correctly installed.
After digging up on SLD I've found the corresponding:
     Installed Software Component AS2Adapter and
     Installed Support Package: AS2Adapter
However, there was something that caught my eye. They both have version '0'. That seemed a bit odd, since evey component has the corresponding version after the installation. Can any of you guys who worked with the Seeburger Adapter check if this setting is alright? Can you guys check your SLD SWCV?
If you think there's something missing and the SLD setting has nothing to do with it, please give me an idea....
Thanks a lot in advance.
Another Question:
The imported .tpz in the IntegrationRepository 'SEEBURGER_EDI_ADAPTER' responsible for the corresponding AS2 Adapter which I'm trying to use in the IntegrationDirectory corresponds to a Software Component Version with a key from the SLD where we can check the associated GUID.
Well, I was expecting to see this SWCV in the SLD, but nothing...I've searched all the generated GUIDS in the SLD from ContentMaintenance and there's not there...
Am I missing any activation?
Edited by: Gonçalo Mouro Vaz on Apr 17, 2008 12:44 PM

Hi........
          As far as the version is concerned it has nothing to do with the functioning of that particular SWC in SLD.....its not a mandatory requirement........u can simply import the SWCV in the
Integration Repository->Tools->Transfer from System Landscape Director->Import Software Component Versions...  and carry on with your work...
No activation as such is needed.....
compliment with points if helpful.........
Thank you.

Similar Messages

  • Bsi mapping in seeburger adapter

    hi experts,
    i want to know about bic mapping in idoc to edi scenarios in which i am using seeburger adapter.please help me and provide me some documentation.

    Hi,
    BIC is mapping tool which converts EDIFACT to EDI_XML.
    You will be accepting EDI flat file i.e. csv file and using BIC you will map it 1:1 mapping ....this flat file will be converted into EDI_XML after mapping.
    Check this for Conversions-
    /people/bla.suranyi/blog/2006/06/08/sap-xi-supports-edifact
    http://www.seeburger.it/fileadmin/it/pdf/2005_04_sapphire_Ferrero_transcript.pdf
    http://www.seeburger.com/fileadmin/com/pdf/AS2_General_Overview.pdf
    SAP Adapters
    EDI with XI
    http://www.seeburger.com
    http://www.seeburger.com/fileadmin/com/pdf/SEEBURGER_SAP_Adapter_engl.pdf
    http://www.seeburger.com/fileadmin/com/pdf/Butler_Group_SEEBURGER_Technology_Audit.pdf
    http://www.sap.com/france/company/events/2006/02-01-Automotive-Seeburger.pdf
    http://h41123.www4.hp.com/presentations/ISUG/XISeeBurger.ppt
    http://www.sap.com/asia/company/events/nwtechdays/presentation/australia-slides/Pre-Built_Integration.pdf
    http://h41123.www4.hp.com/presentations/ISUG/XISeeBurger.ppt
    Regards,
    Akshay Jamgaonkar.
    Don't forget to reward points.
    Message was edited by:
            Akshay Jamgaonkar

  • EDI SEEBurger Adapter

    We are evaluating  XI for ANSI X12 EDI , Have some  EDI Quesitions using SEEBurger Adapter.
    1) Does SEEBurger Adpater has ANSI X12 Enveloping and De-Enveloping capabilities ???  If Yes,how this is configured /Developed.
    2) Does SEEBurger Adapter has capability of generating sequential ISA control numbers by Trading Partner ??? If Yes,how this is configured /Developed.
    3) Can It perform  EDI Structure validation based on the  EDI standard  rules (For eg: Looping structures, Element qualifier restriction list .....)

    Hi,
    Seeburger is a tool which will conver any type of standard EDI format into XML.
    All standard EDi mappings are predefined in seburger,we have to install in XI Server and use that standard mappings.
    Check this links
    SEEBURGER
    http://www.seeburger.com
    Please see the below blogs
    /people/bla.suranyi/blog/2006/06/08/sap-xi-supports-edifact
    /people/william.li/blog/2006/03/17/how-to-get-started-using-conversion-agent-from-itemfield
    /people/paul.medaille/blog/2005/11/17/more-on-the-sap-conversion-agent-by-itemfield
    http://www.stylusstudio.com/edi/XML_to_X12.html
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/b0b355ae-0501-0010-3b83-8f2bb566fa47
    Details on XI EDI adapter from seeburger
    Check this for Conversions-
    /people/bla.suranyi/blog/2006/06/08/sap-xi-supports-edifact
    http://www.seeburger.it/fileadmin/it/pdf/2005_04_sapphire_Ferrero_transcript.pdf
    http://www.seeburger.com/fileadmin/com/pdf/Butler_Group_SEEBURGER_Technology_Audit.pdf
    http://www.seeburger.com/fileadmin/com/pdf/AS2_General_Overview.pdf
    SAP Adapters
    EDI with XI
    http://www.seeburger.com
    http://www.seeburger.com/fileadmin/com/pdf/AS2_General_Overview.pdf
    http://www.seeburger.it/fileadmin/it/pdf/2005_04_sapphire_Ferrero_transcript.pdf
    http://www.seeburger.com/fileadmin/com/pdf/SEEBURGER_SAP_Adapter_engl.pdf
    http://www.seeburger.com/fileadmin/com/pdf/Butler_Group_SEEBURGER_Technology_Audit.pdf
    http://www.sap.com/france/company/events/2006/02-01-Automotive-Seeburger.pdf
    http://h41123.www4.hp.com/presentations/ISUG/XISeeBurger.ppt
    http://www.sap.com/asia/company/events/nwtechdays/presentation/australia-slides/Pre-Built_Integration.pdf
    http://www.seeburger.com
    http://www.seeburger.it/fileadmin/it/pdf/2005_04_sapphire_Ferrero_transcript.pdf
    http://www.seeburger.com/fileadmin/com/pdf/Butler_Group_SEEBURGER_Technology_Audit.pdf
    http://www.sap.com/france/company/events/2006/02-01-Automotive-Seeburger.pdf
    http://h41123.www4.hp.com/presentations/ISUG/XISeeBurger.ppt
    http://www.seeburger.com/fileadmin/com/pdf/AS2_General_Overview.pdf
    http://www.seeburger.it/fileadmin/it/pdf/2005_04_sapphire_Ferrero_transcript.pdf
    http://www.seeburger.com/fileadmin/com/pdf/SEEBURGER_SAP_Adapter_engl.pdf
    http://www.seeburger.com/fileadmin/com/pdf/Butler_Group_SEEBURGER_Technology_Audit.pdf
    http://www.sap.com/france/company/events/2006/02-01-Automotive-Seeburger.pdf
    http://h41123.www4.hp.com/presentations/ISUG/XISeeBurger.ppt
    http://www.sap.com/asia/company/events/nwtechdays/presentation/australia-slides/Pre-Built_Integration.pdf
    Regards,
    Phani
    Reward Points if Helpful

  • EDI TRADACOM through Seeburger Adapter into PI

    Has anybody configured communication channel in PI using Seeburger Adapter to convert EDI TRADACOM into xml ?
    Is there a useful tutorial to have a look at ?

    >>Has anybody configured communication channel in PI using Seeburger Adapter to convert EDI TRADACOM into xml ?
    Yes
    >>Is there a useful tutorial to have a look at ?
    Well, there is nothing specific avauilable for TRADACOM. TRADACOM is just a type of format as we have EDIFACT OR X12. You can search for EDIFACT related articles/blogs on SCN (there are many). The only thing you then need is to use TRADACOM related mapping name in BIC module wherever you see EDIFACT mapping name.
    One more thing, for using TRADACOM, there is a separate licence where Seeburger provides the TRADACOM related SWC with all the formats. So talk to Seeburger about this as well.
    Regards,
    Prateek Raj Srivastava

  • Seeburger adapter XML-EDI info

    I would like know about Seeburger EDI adapter( XML-EDI) how it works, If any body have Seeburger adapter documentation pls. send some to [email protected] Thanks in advance.

    Please see the below blogs
    /people/bla.suranyi/blog/2006/06/08/sap-xi-supports-edifact
    /people/william.li/blog/2006/03/17/how-to-get-started-using-conversion-agent-from-itemfield
    /people/paul.medaille/blog/2005/11/17/more-on-the-sap-conversion-agent-by-itemfield
    http://www.stylusstudio.com/edi/XML_to_X12.html
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/b0b355ae-0501-0010-3b83-8f2bb566fa47
    Details on XI EDI adapter from seeburger
    Check this for Conversions-
    /people/bla.suranyi/blog/2006/06/08/sap-xi-supports-edifact
    http://www.seeburger.it/fileadmin/it/pdf/2005_04_sapphire_Ferrero_transcript.pdf
    http://www.seeburger.com/fileadmin/com/pdf/Butler_Group_SEEBURGER_Technology_Audit.pdf
    http://www.seeburger.com/fileadmin/com/pdf/AS2_General_Overview.pdf
    SAP Adapters
    EDI with XI
    http://www.seeburger.com
    http://www.seeburger.com/fileadmin/com/pdf/AS2_General_Overview.pdf
    http://www.seeburger.it/fileadmin/it/pdf/2005_04_sapphire_Ferrero_transcript.pdf
    http://www.seeburger.com/fileadmin/com/pdf/SEEBURGER_SAP_Adapter_engl.pdf
    http://www.seeburger.com/fileadmin/com/pdf/Butler_Group_SEEBURGER_Technology_Audit.pdf
    http://www.sap.com/france/company/events/2006/02-01-Automotive-Seeburger.pdf
    http://h41123.www4.hp.com/presentations/ISUG/XISeeBurger.ppt
    http://www.sap.com/asia/company/events/nwtechdays/presentation/australia-slides/Pre-Built_Integration.pdf
    http://www.seeburger.com
    http://www.seeburger.it/fileadmin/it/pdf/2005_04_sapphire_Ferrero_transcript.pdf
    http://www.seeburger.com/fileadmin/com/pdf/Butler_Group_SEEBURGER_Technology_Audit.pdf
    http://www.sap.com/france/company/events/2006/02-01-Automotive-Seeburger.pdf
    http://h41123.www4.hp.com/presentations/ISUG/XISeeBurger.ppt

  • Seeburger Adapter Module Error

    Hi
    I have a scenario orders idoc to x12,I have done bic maaping & deployed sda file to SDM.And the paramater i have defined at the adapter module
    bic mappingname
    bic destTargetMsg
    bic destSourceMsg
    And the error i am getting is
    2007-04-16 16:13:51 Success process()
    2007-04-16 16:13:51 Error process()
    2007-04-16 16:13:51 Error process()
    2007-04-16 16:13:51 Error MP: exception caught with cause java.lang.NullPointerException
    2007-04-16 16:13:51 Error Exception caught by adapter framework: null
    2007-04-16 16:13:51 Error Delivery of the message to the application using connection File_http://sap.com/xi/XI/System failed, due to: com.sap.aii.af.ra.ms.api.RecoverableException: java.lang.NullPointerException.
    2007-04-16 16:13:51 Error The message status set to NDLV
    Any hep would be highly appreciated
    Thanks
    sri

    Hi Sriram,
    Which Seeburger Adapter are you using to transmit your converted X12 message?
    Rgds,
    Sam Raju
    null

  • Error in Oubound message using Seeburger Adapter

    Hi,
    I'm getting this error on the Adapter engine when trying to generate an outbound EDI message with Seeburger adapter:
    2007-01-24 13:33:29      Error      Unable to forward message to JCA adapter. Reason:
    Fatal exception: com.seeburger.xi.connector.queue.QueueEntryRejectedException:
    Entry rejected due to error in resource management: null, Entry rejected due to
    error in resource management: null     
    2007-01-24 13:33:29      Error      MP: exception caught with cause
    javax.resource.ResourceException: Fatal exception:
    com.seeburger.xi.connector.queue.QueueEntryRejectedException: Entry rejected due
    to error in resource management: null, Entry rejected due to error in resource
    management: null     
    2007-01-24 13:33:29      Error      Exception caught by adapter framework: Fatal
    exception: com.seeburger.xi.connector.queue.QueueEntryRejectedException: Entry
    rejected due to error in resource management: null, Entry rejected due to error
    in resource management: null     
    2007-01-24 13:33:29      Error      Delivery of the message to the application using
    connection File_http://sap.com/xi/XI/System failed, due to:
    com.sap.aii.af.ra.ms.api.RecoverableException: Fatal exception:
    com.seeburger.xi.connector.queue.QueueEntryRejectedException: Entry rejected due
    to error in resource management: null, Entry rejected due to error in resource
    management: null: javax.resource.ResourceException: Fatal exception:
    com.seeburger.xi.connector.queue.QueueEntryRejectedException: Entry rejected due
    to error in resource management: null, Entry rejected due to error in resource
    management: null.     
    Any ideas?
    Rgds,
    Yves

    Yves,
    I think there is some problem in invoking the seeburger adapter. Have you installed the adapter? Also after installing you have to import the metadata. Check this document for further help:
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/6dc02f5d-0601-0010-cd9d-f4ff9a7e8c33
    ---Satish

  • How do we do File content conversion using SFTP SEEBURGER Adapter

    HI All,
              Can we do FCC using SFTP SEEBURGER adapter. If yes how?
    XIer

    Dynamic attributes are part of the XI message. They provide options for dynamical configuration of SFTP receiver channels (Outbound direction) using parameters that have been dynamically added or set by modules and mappings before the SFTP adapter. These attributes can be set using the Attribute Mapper module for example. Besides, the SFTP adapter dynamically adds specific parameters to the XI message on Inbound case, which can be used by the modules and mappings after SFTP adapter.
    Check also
    /people/william.li/blog/2006/04/18/dynamic-configuration-of-some-communication-channel-parameters-using-message-mapping
    /people/daniel.graversen/blog/2006/10/05/dynamic-configuration-in-adapter-modules
    Regards
    Naycho

  • How to configure SFTP seeburger adapter

    Hi All,
               Has anyone worked with Seeburger adapter? Could someone tell me how to configure it in XI ?
    XIer

    Hi XIer,
    Check out the following links
    http://www.seeburger.com/sftp_xi/
    http://www.seeburger.com/fileadmin/com/pdf/SAP_Exchange_Infrastructure_Integratio_Strategy.pdf
    Best Regards,
    Guza
    Message was edited by:
            liad aharoni

  • Integration of Seeburger Adapter in Solution Manager for Monitoring

    Hi Experts ,
    Can we Integrate the  monitoring of Seeburger adapter into the Solution Manager dashboard under central PI Monitoring ?
    We are using   AS2, FTP and sSFTP seeburger adapters here.
    Regards,
    Kamal
    Edited by: KAMAL KUMAR on Jan 11, 2012 2:33 PM

    Hi,
    check  [this.|http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/408e1501-fb8c-2e10-edba-f51f13cde64e?QuickLink=index&overridelayout=true]
    Page 29 has useful information on adapter/channel monitoring.
    -santosh.

  • Error in Seeburger Adapter

    Hi Experts,
              We are sending a message to a Partner, and i can see the message processed succesfully in the SXMB_MONI and also in the Runtime Workbench, but when i see in the seeburger adapter monitoring for the MDN's i noticed that the message was in Error  MIC not verified # MIC values not verified sha1-null. At first i thought the error was related to certificate, but when the message was retried after some time it was sucessfully processed and we got positive MDN's also. Could you please let me know when exactly the Error comes? and what can be done to solve this issue.
    Many Thanks.
    Edited by: Ravi Kumar Nakerikanti on Aug 13, 2008 4:51 AM

    Hi,
    You have used the AS2 Message type MDN (Message Disposition Notification).
    An MDN may optionally be signed, in which case the recipient can authenticate the sender of the MDN and check its integrity. A valid, signed MDN together with a valid MIC reported by the MDN can be used by the sender of the payload message
    But here this validation is failed ...and have raised the error like
    "MIC not verified # MIC algorithms not verified [LOC: com.seeburger.as2.component.MDNHandler.parseMDN]"
    refer
    http://www.seeburger.com/fileadmin/com/pdf/SEEBURGER_AS2_Spoke_Unit_for_Trading_Partner_Integration.pdf
    Thanks
    Swarup

  • Sender / Receiver ID mapping for EDI interfaces and Type of seeburger adapt

    We need to set up a interface using Seeburger adapter for Purchase order IDOC to 850 EDI mapping.. After reading from SDN,
    1) We can use the standard mapping in BIC MD to do E2X and X2E mapping..
    2) We can use any of the AS2, EDI generic adapter, Seeburger FTP adapter or Seeburger SFTP adapter...
    How do we decide which adapters should be chosen? I can see that it makes sense to use SFTP adapter or AS2 adapter for security...
    Also how do we map Sender and Receiver IDs on the EDI message.. Should this be hardcoded as part of mapping or is there any facility in seeburger adapter to do this? I saw some references to Party Identifiers and not sure how it is used in setting up Sender/ Receiver ID
    Also the graphical mapping to convert IDOC XML to EDI XML, Do we have standard mapping defined or do we need to create our own graphical mapping.

    Hi Kris,
    I had worked in the somehow same scenario, It was IDOC to EDIFACT file.
    I can give you few clues which might be helpful
    In BIC MD you have to create your own mapping if the standard mapping is not available (First check all the standard mappings in BIC). For your reference you need X2E mapping, as your scenario is IDOC to 850 EDI.
    "the graphical mapping to convert IDOC XML to EDI XML, Do we have standard mapping defined or do we need to create our own graphical mapping."
    In graphical mapping i created my own mapping, Seeburger has given some sample mappings you can check those for your reference (SEEBURGER_GENERIC_EDI software component). Mostly you have to create your own. You need a document from your functional consultant so that you are able to map correct fields and constants.
    "how do we map Sender and Receiver IDs on the EDI message.. Should this be hardcoded as part of mapping or is there any facility in seeburger adapter to do this? I saw some references to Party Identifiers and not sure how it is used in setting up Sender/ Receiver ID"
    This has been generally hardcoded in message mapping (In my case i hardcoded). If any of ur IDOC field contains that data you can map that field. But better Idea is ask your functional expert.
    "How do we decide which adapters should be chosen? I can see that it makes sense to use SFTP adapter or AS2 adapter for security... "
    You can choose adapter according to your requirement. In my case i used File adapter as i have to create file in PI server only. My suggestion you can use SFTP for seeburger
    Hope these points are helpfu for u
    Regards,
    Shradha

  • How to import seeburger adapter and mdm adapter in sap pi 7.3

    Hi all,
    how to import seeburger adapter and mdm adapter in sap pi 7.3

    Hello
    To import the Seeburger adapters, follow the instructions in the Master Installation guide and the individual guides for each of the adapters. These are available with the Seeburger software downloads.
    Regarding the MDM adapter, this is the wrong forum for that question. Try the MDM forum (but first, try searching the forum as this is a very basic question).
    Regards
    Mark

  • Seeburger adapter monitoring

    We are running Seeburger AS2 adapter with XI3.0.
    All inbound messages that the adapter can handle are passed to XI and we have access to those from XI message monitoring.
    From there we have alerting setup.
    Whenever an external party presents a message with a bad certificate the AS2 adapter refuses the message.
    We can see trace of that in the adapter monitor. But there is no message in error passed to XI. So nothing we could get in message monitoring.
    We saw we have a logfile containing those errors on the server. We could setup a logfile monitor on this file and get errors in CCMS. And from there, we could trigger alerts. But that does not look very elegant.
    Is there a best way to get Seeburger adapter error generating alerts ?

    Hi,
    If the check is happening in the Adapter then the Alerts needs to be raised by Adapter framework.
    So you have to set up Alert rule for the Adapter framework.
    The message goes to message montioring only if the adapter sends the date to the Adapter engine and then you can see the message in the message monitoring.
    If the rejection is at AF levelt hen you need to check in the Communication Channel if you are getting the Error?
    Regards
    Vijaya

  • Seeburger Adapter

    Hi all,
    I have installed a generic seeburger FTP adapter, but I dont have any VAN connectivity at present. Can I convert the EDI ANSI X12 format to xml with this installation or it requires VAN connectivity to do this.
    In this case do we require the BIC mapper? if so how to work with BIC mapper?
    In the communication channel, I am able to see the installed Seeburger FTP adapter but it does not show the transport and message protocol. Is this related to the Installation/setup of VAN connection.
    Regards,
    Nithiyanandam

    Hello..
    SeeBurger is a leading provider of global business integration solutions.
    Market launch of the most successful EDI solution for the automotive industry in 1986.
    the company today serves more than 7,000 customers in 42 countries and more than 15 industries through its flagship B2B Gateway and related products and services.
    First company worldwide to receive certification for SAP R/3
    Building a closer partnership with SAP.
    Extended any-to-any-conversion.
    The SEEBURGER Business Integration Converter (BIC) is an Any-To-Any Format converter, used to translate EDI data and legacy data formats into XML and vice versa. It can also be used for complex,high performance XML-to-XML mappings or to interface to existing JDBC Data Sources.
    Supported EDI formats include: ANSI, EDIFACT, INHOUSE, IDOC, XML Schema, XML DTD, CSV,Delimited Data, positional data, SWIFT, EANCOM and many more.
    Mapping Designer, a graphical tool, easily defines data format conversions via drag and drop functionality, enabling easy integration between source and destination files. A central mapping reposiu00ADtory enables comprehensive support of versioning and deployment support, such as self-testing and auditing.
    The SAP Exchange Infrastructure message format is based on XML, but it also can work with non-XML data using attachments. In some cases it may be necessary to convert the main XML document in a message, into a non-XML document. The use of BIC is very common in Business-to-Business scenarios where EDI standards are in use.
    The Business Integration Converter (BIC) of Seeburger is based on Java JIT Technology and can be used for small real-time messages, as well as very large master data (i.e.Catalogs) batches.
    BIC can convert outbound invoices from XML format (used in SAP XI) to an EDIFACT invoice. The conversion can be executed before the message is transmitted to the business partner. The other way around, once an EDIFACT message has been received from the business partner, it must first be converted to XML format, which is the format SAP XI supports.
    The most direct way of using the Seeburger adapters is to configure the BIC as a module. BIC will allow you to do the following
    Once you install BIC, you need to do Import the Generator Mappings into the Project Explorer of BIC MappingDesigner.
    You can find Generator Mappings as a ZIP file in the following location <BICMappingDesignerInstallationDirectory>\user\bicmd\Exchange and select the file prj_GeneratorMappings.zip.bicmd.
    In MappingDesigner select File Import Generator Mappings Zip File prj_GeneratorMappings.zip.bicmd Clik on “Add” and “OK”.
    Once Import is done you can see “Generator Mappings” in BIC Mapping Designer.
    The SEEBURGER Adapter runs on the SAP WEB AS (J2EE Engine)
    The SEEBURGER Adapter is integrated into the SAP Exchange Infrastructure over JCA (Java Connector Architecture)
    Consequence :
    Supply of the complete SEEBURGER EDI/B-to-B-Technology-Suite within SAP NetWeaver
    Central File of Business Content (mappings, integration processes) in the Integration Repository of SAP XI
    Central configuration and design by using the Tools of XI in the configuration
    Central monitoring and alerting over SAP XI
    Seeburger Solutions Overview
    BIC Mapping Module
    Functional Acknowledgement Solution
    Operational Dashboard / Archiving
    Invoice Solutions
    Communication
    The Business Integration Converter (BIC) from SEEBURGER is a converter for the implementation of data formats.
    Following formats are available:
    ANSI X.12 (American National Standards Institute)
    CSV (Comma Separated Variable formats)
    EDIFACT (all subsets)
    INHOUSE (VDA, flatfiles, e. g. SAP IDoc)
    SWIFT (banks)
    TRADACOM (Trading Data Communications Standard)
    XML (DTD‘s and SCHEMATA)
    Able to classify messages into the following message types:
    XML
    EDIFACT
    Ansi X 12
    Tradacom
    VDA
    IDOC
    Swift
    Inhouse
    XML Ansi X 12
    XML EDIFACT
    XML Tradacom
    XML VDA
    XML IDOC
    Go through this links..
    Some more..
    http://www.seeburger.com
    http://www.seeburger.com/fileadmin/com/pdf/AS2_General_Overview.pdf
    http://www.seeburger.it/fileadmin/it/pdf/2005_04_sapphire_Ferrero_transcript.pdf
    http://www.seeburger.com/fileadmin/com/pdf/SEEBURGER_SAP_Adapter_engl.pdf
    http://www.seeburger.com/fileadmin/com/pdf/Butler_Group_SEEBURGER_Technology_Audit.pdf
    http://www.sap.com/france/company/events/2006/02-01-Automotive-Seeburger.pdf
    http://h41123.www4.hp.com/presentations/ISUG/XISeeBurger.ppt
    http://www.sap.com/asia/company/events/nwtechdays/presentation/australia-slides/Pre-Built_Integration.pdf
    Reward Points if it is really useful to you.....
    Thanks,
    Satya Kumar..

Maybe you are looking for

  • I can't hear an incoming call, but they can hear me

    I can make a call, and it connects but I can't hear the person I'm calling. They can hear me.  I figured out that I can hear only if I set the call on Speaker. 

  • Creation of a dashboard link into a report

    Hi, I created a dashboard to display reports folders. A user can access to the link and select the report needed. User doesn't use standard Oracle IHM. I would like to create others dashboards and add it as link into the first dashboard (cannot use t

  • Audio Preview Problem

    I'm capturing a bunch of video and want to preview the audio at the same time. The Preview works fine until I push the "Log Clip" button after setting the in and out for my first clip, when I resume playback the audio goes all sketchy. It still plays

  • 970A-G46 CPU Compatability?

    I want to upgrade to the AMD FX 9370 but do not see it listed as being compatible?  I'm wondering if the compatability page is current?

  • Default dashboards for users

    How can I set default dashboards for users on startup? I mean always a user start OBI,one (default) dashboard should be shown...How can I set this property? Can anyone tell me in detail?