Seeburger FTP
Hello,
if i have to send a file to a FTP using SFTP.
can seeburger FTP adapter help ? and we will need send or rec FTP adapter for this?
Thank you.
1) seeburger SFTP is a different adapter ? or an option to choose in any seeburger adapter?
2) the script for open SSH gets file from remote server to local server using SFTP. How will we configure the scenario for this?
Thank you
Similar Messages
-
Problems with Seeburger FTP Receiver adapter
Hello,
I am working on a scenario sending ORDERS05 Idocs to EDI vendors.
For this i have configured Seeburger Receiver FTP adapter with 2 modules to convert XML-EDI format. Since this is the test, I have pointed Seeburger to local FTP server with following settings
Hostname <Hostname of our FTP server>
Port <Port # of our FTP server>
Host Path/VAN partner id <some local directory of FTP server>
Payload mode: Maindocument.
At runtime i received following exception
Message could not be forwarded to the JCA adapter. Reason: Fatal exception: javax.resource.ResourceException: >> Description: com.seeburger.jftp.app.exception.FtpExceptionSoftProcessingError: Unexpected reply: 500 'SITE system 1': command not understood>> Details: com.seeburger.jftp.app.exception.FtpExceptionRethrowError: Error in session: {type:FTPConnectionId}{binding:82ea8d3089dc3e898ae2e608d9d8487d}{channel:a52d1aaa8dd63ff59c2f590e78586a77}{toparty:TestEDIParty} CAUSED BY: com.seeburger.jftp.app.exception.FtpExceptionOpenConnectionError: Error while connection to remote host CAUSED BY: com.seeburger.jftp.app.exception.FtpExceptionRethrowError: Error while executing command QUOTE site system 1 CAUSED BY: com.seeburger.jftp.app.exception.FtpExceptionSoftProcessingError: Unexpected reply: 500 'SITE system 1': command not understood>>SendingStatus: NOT_TRANSMITTED>>FaultCategory: COMMUNICATION_ERROR>>Retryable: true>>Fatal: true
Few questions related to this
1] can we use Seeburger adapter to generate EDI files on local FTP server
2] If not Seeburger can we use normal File adapter to do the same. I tried the same by configuring BIC module in File adapter so that it would convert XML to EDI format and was hoping file to be generated on FTP server. It generated one line XML file with following text "<info>Converted message locates in a attachment</info>". Any idea how to retreive attachments in File receiver adapter (as far as i know no attachments are supported in File receiver adapter).
Any idea how to generate EDI files with Seeburger FTP on test server?
Thanks in advance.
Regards
RajeevHi Rajeev,
> 1] can we use Seeburger adapter to generate EDI files on local FTP server
Yes we can use.
> Any idea how to generate EDI files with Seeburger FTP on test server?
It is like a normal process, how to generate the EDI files in normal means without FTP. Check this link
https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/10b17369-9522-2c10-84a6-d75d8a8ace22
BIC
https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/00b66651-eeea-2b10-e5a6-8459ec30d948
Regards
Ramesh -
Configuring a Seeburger FTP Receiver Adapter
Hello,
I am trying to build a scenario where SAP ECC 6 sends an invoice to a customer via EDI.
We are using ECC 6.0 and PI 7.0 and the Generic Seeburger EDI Adapters. The VAN is a GEIS EDISWITCH VAN (Eircom in Ireland).
I am able to successfully send an IDoc from ECC 6 and into PI where a Seeburger map converts the message to EDI-XML format. I can use a file adapter to create a file in normal EDI format. But I can't get the Seeburger FTP adapter to work with the VAN.
I have configured the correct IP, port, username and password but I keep getting the following message when the communication channel tries to send the message:
<h6>Message processing failed. Cause: javax.resource.ResourceException: Fatal exception: com.sap.aii.af.ra.cci.XIRecoverableException: >> Description: com.seeburger.jftp.app.exception.FtpExceptionSoftProcessingError: Unexpected reply: 501-Syntax errors in parameter. usage: %[recipient id]%[APRF] where either [recipient] or [APRF] can be omitted. (to change your current default SEND relationship). %% (places you in your 'HOME' TR). &['s'|'single'] ('get' command gets single file). &['m'|'multiple'] ('get' command gets multiple files). >> </h6>
The FTP session is expecting a PUT command with the recipient id and APRF as parameters but these are not getting passed. I suspect this is because I am not passing the correct variables to the receiver adapter but I don't know what variables it expects and where they should be specified. And I can't find the answers in the documentation.
Can anyone shed some light on what I need to do?
Thanks,
BenHi Prateek,
Thanks for your comments. The channel is set to GEIS(GeMarkIII). There is nowhere to specify a directory or filename. The settings I have used are as follows:
Adapter Type: FTP (http://seeburger.com/xi)
Receiver
Transport Protocol: FTP
Message Protocol: GEIS/GeMarkIII
Adapter Engine: Integration Server
Host name: <IP address of VAN server>
port: 21
User Id: <Our mailbox number>
Password: <Correct password>
Host path/VAN Partner ID: <blank>
Script file: <blank>
Transfer type: ASCII
Connection mode: Passive
Use keep alive: <Not checked>
Security Mode: None
Proxy Mode: none
Resource ID: <blank>
Deliver transmission report: <not checked>
Payload mode: Attachment
Attachment ID: SeeburgerMain
Channel status: Active
Use dynamic attributes: <Checked>
Use non-empty attributes: <Checked>
Request displayed report: <Not checked>
Request dispatched report: <Not checked>
Report timeout (minutes): 720
Handle received reports: Refer reports to XI system
There is nowhere in the communication channel configuration that allows me to specify the receiver ID or the APRF. The documentation say this is read from the EDI data and the relevant fields are populated.
Any ideas?
Thanks,
Ben -
Seeburger FTP Adapter And SAP PI 7.1
Hi Everyone,
Just a few questions about Seeburger FTP adapter please. Bit of background for clarity, we are doing an implementation using Seeburger FTP and sap PI 7.1 picking up EDIFACT (Orders) and returning (DESADV, ORDERSP, INVOICES). However we are not using any BIC, using another tool for EDIFACT -> EDIFACT-XML conversion (conversion agent) and in-house mapping development using graphical mapping.
So couple of things which I haven't been able to figure out from the standard documentation for Seeburger FTP adapter:
1) First is the functional ACK which we are meant to send back to the VAN is that a STANDARD FUNCTIONALITY with Seeburger FTP adapter?
2) Because we are receiving a mix bag EDIFACT interchange on the way IN, I need to split messages accordingly and pass them on to the relevant channels and mappings. By using the standard module Splitter can I achieve that?
3) Lastly some of the standard validations which are applicable to EDIFACT are they supported within the FTP adapter automatically? e.g. Counting number of messages in one interchange etc.
Any help in this regard will be really great.
regardsNow a Good news.
If you are using Seeburger version 2.1 (which you should be as you want it for PI 7.1), then there is an Internal Classifier and Split option for FTP adapter. You just need to tick checkbox "Use built-in splitting" and you are done. Then I believe there won't be any need for considering all these problems. The earlier version of Seeburger with PI 7.0 doesn't have such option and that could be the reason you haven't received any appropriate response yet.
Still I will reply all your questions considering that "your case is of PI 7.0". -> remember PI 7.0
>>even with just splitter we should be able to break it up?????? or am I wrong in thinking this?
No. You even need BIC or an equivalent custom module for achieving this.
>>I can't visualize where to handle the overall message count in one Interchange any suggestions?
You need to write an adapter module for this. Not sure about the code but this module has to be added before the split happens.
>> seeburger ftp adapter it does talk about a lot of reports which are available on sender/reciever actions. e.g. delivered, despatched etc. Are these reports not essentially ACKs?
These reports are the ones used at the receiver side for getting the ACKs from the receiver. Your requirement is at present for sender scenario.
Regards,
Prateek -
Hi,
I'm getting a problem when pulling a file with the Seeburger FTP adapter. The error is logged in the ftp.trc file but I'm not seeing anything in sxmb_moni. Any body would know where the "pulled" file is temporary stored before being processed by the integration server?
Rgds,
Yvesok, now it makes a bit more sense, you basically got 2 problems:
1.) you can't see the file the FTP has picked up
2.) BIC runs on error
some suggestions to solve
1) See page 43 of the SAPXI_FTPAdapter_en.pdf documentation
Message Dumping
For debugging purposes, it is possible to dump the complete FTP files to a directory on the SAP XI
Server.
Message dumping can be enabled via the J2EE Admin. Go to the ConnectorContainer service and
select the FTP/VAN Adapter. Go to the ManagedConnectionFactory tab and then to the Properties
sub-tab. Now the transmissionDataDump property can be changed:
When the save button is clicked, the adapter is restarted and dumping is activated / deactivated.
Be sure to only use dumping for debugging purposes, since it reduces the performance of
the FTP/VAN Adapter.
The dump files are saved to the <your sap installation>/server0/seeburger/ftp/dump directory.
Another option is, do you use the Seeburger Archiving Solution ? Then you can configure a FileStore before the BIC Module and you'll be able to download the document from the Archive. See SAPXI_Archiving_en.pdf
2) Total Offset 2409, you can check in the file that your Vendor send you it is probably toward the end of the file. Maybe they have an extra CRLF after the IEA, that would confuse BIC or the VAN adds like an EOF, which can't be processed. Maybe that happens when the VAN is decrypting the Message from AS2.
Why don't you do AS2 directly with your Trading Partner and save the VAN cost ?
Regards,
Andrea -
Hi there,
We have the following scenario. We want to get EDI 861 via ftp from our partner to XI to our R3. The challenge we are facing is getting started with seeburger adapters. We looked into seeburger ftp/van adapter. We are not using VAN. Is it possible to configure this adapter in sender communication channel for our scenario? We tried it, but we are stuck at choosing the message protocol, because we get only the VAN supported message protocols from the drop down menu.
Our goal is to get the EDI 861 from our partner via ftp, parse it to XML representation, map the xml to equvalent IDOC and send it to our R3. Is there a seeburger adapter that receives the edi and parses it into? If yes, how do we go about to solve this issue. Right now, we are not able to configure the adapter right so that we could get the edi flat file via ftp and get the parsed edi xml in xi moni.
Your help is greatly appreciated.
ThanksHi,
You need to configure the AS2_MDN_Sender Communication Channel with transport protocol is AS2 and Message protocol is Reports.
Regards,
Ramesh -
AS2 Adapter MDN option and Seeburger FTP adapter
Hi Experts,
I configured the a scenario AS2 to File, it takes all the signals from customer and placed in a particular folder, later by using some other scenario it goes to the seeburger workbench and process further.
Now I sent one outbound (810) signal to customer, then we will receive the MDN back, so we receive MDN also in the specific folder (by using the above AS2 to File configuration)? or we need to create separate CC and Sender Agreement by using the sender party?
One more Question about Seeburger FTP adapter
I configured the sender side FTP adapter to pick the functional acknowledgement (997), in the component monitoring it is displaying the below error
"Cannot create reservation, reason: Resource not available for reservation!; affected object : Resource (type:LOGICAL/id:ABCFTP/name:Logical resource name for abc to access the FTP mailbox)", I have deleted the old reservation in seeburger work bench resource management, still no luck.
Could you please guide me.
Thanks
RameshHi Experts,
I configured the a scenario AS2 to File, it takes all the signals from customer and placed in a particular folder, later by using some other scenario it goes to the seeburger workbench and process further.
Now I sent one outbound (810) signal to customer, then we will receive the MDN back, so we receive MDN also in the specific folder (by using the above AS2 to File configuration)? or we need to create separate CC and Sender Agreement by using the sender party?
One more Question about Seeburger FTP adapter
I configured the sender side FTP adapter to pick the functional acknowledgement (997), in the component monitoring it is displaying the below error
"Cannot create reservation, reason: Resource not available for reservation!; affected object : Resource (type:LOGICAL/id:ABCFTP/name:Logical resource name for abc to access the FTP mailbox)", I have deleted the old reservation in seeburger work bench resource management, still no luck.
Could you please guide me.
Thanks
Ramesh -
Issues with Seeburger FTP adapter
Can one of you with Seeburger FTP adapter experience share some information on these issues I'm facing
1. Do I need to setup resource management in Seeburger workbench. If so, do I need to configure, resource, server and reservations. Do you have more information and what parameters I need here.
2. In the Seebuger FTP adapter, I have
Module Key - exit
Parameter Name - JNDIName
Paramter Valu - deployedAdapters/SeeXIFTP/shareable/SeeXIFTP
JNDIName, should I be replacing this with some other name. I'm trying to get Seeburger FTP to work and in the messaging monitor, I see the message as passed to Module Processor but it does go anywhere from there.
Can one you throw some light on this subject...what to expect from this definition.
Thank you for all your replies,
ParimalaI'm resending this since I did not have any luck with it the first time.
We also have an oss note waiting to be responded on this subject.
When I send messages using Seebuger FTP adapter, I see the following information in the SAP message monitor -
"Message entered module processor exit bean and will be transferred to JCA adapter".
But does not get to IBM VAN mailbox. How do I trace from this point onwards.
Should I use Seeburger monitoring tool for this? If so, I don't see anything in Seeburger monitoring (used all criteria).
Please let me know if you have any information on this subject.
Thanks,
Parimala -
Difference between Seeburger FTP and OFTP adapters
hi,
Can anybody tell me the difference between Seeburger FTP and OFTP adapters?
On what basis should one make a business decision as to which adapter to go for?
Kindly help urgently.
Regards,
LoveenaHi ! Loveena
Seeburger EDI Adapter provides an EDI solution on internet via HTTP or AS2 to replace the expensive VAN. It provides some pre-built mappings for IDOC to ANSI X12(810,850,855,856 etc.,) and Idoc to EDIFACT(ORDERS,DESADV,INVOIC etc.,) and has the ability to build your own. These pre-defined mappings transform the IDOC-XML to EDI-XML format.
Seeburger Adapters are used to Connect the applications which are using Message protocol/Transport protocol as CrossIndustry(payment), VAN, OFTP, AS2(EDIINT), Generic and EDI based applications.
Re: Seeburger Adapter
Reg seeburger seeburger
installation
https://forums.sdn.sap.com/click.jspa?searchID=2268965&messageID=3210111
OFTP ist a communication protocol. This has nothing to do with the format you have to transfer.
regards the format you have to clear at which standard you have to transfer the messages. This can be any EDI format. At OFTP area the standard are often VDA or ODETTE.
You can create this messages using different EDI adapters (of course also the mendelson adapter ).
Regards OFTP you need additional software which handle the transfer based on the OFTP standard. Mostly you also need an ISDN card for using this protocol.
We can support you with this software for OFTP transport too.
More info also available at http://www.mendelson-e-c.com/.
have a look at the ACTIS OFTP Adapter
Ref: http://www.actis.atosorigin.de/solutions/en/ACTIS_solutions/SAPXI.php
refer this thread also
When we need Seeburger AS2 & FTP?
XI Seeburger adapters
Adapter for OFTP?!
Thanks !! -
Seeburger FTP Adapater Config Frage
Hallo Support
Beim Anlegen FTP Adapter Art Kanal in der Kommunikation, Transport Protokoll und Nachricht Protokoll Werte sind nicht immer in der Combobox zur Auswahl. Wir haben bereits über die seeburger FTP und BIC Adapter, wie es im Setup Guide. .
Bitte schlagen Sie vor, wie man in dieser Situation.
Danke und GrußHello
While creating ftp adapter type in communication channel,transport protocol and message protocol values are not getting displayed in the combo box for selection. We already installed the seeburger FTP and BIC adapter as explained in setup guide.[At present we are not having VAN setup in our end].
Please suggest how to go ahead in this situation.
Thanks and Regards -
Seeburger FTP adapter Configuration
Hi all,
Can anyone help me how to proceed with EDIFACT D96A-->Idoc Scenario.
Thanks
GopiHi
you have to configure the sender file adapter at the sender side. in the sender file adapter you have to use the BIC module that will convert the EDIFACT msg into EDIFACT XML message.
the conversion of EDIFACT to EDIFACT XML is done by the BIC mapping E2X.
you can create the E2X mapping using the BIC mapper by selecting the option createE2Xmapping
Thanks
Rinku -
Hi,
We are using the FTP adapter and the Seeburger BIC adapter (is configured as a module in the FTP communication channel)
When we receive EDIFACT files the first step that is performed is the conversion from EDIFACT to XML messages (done by Seeburger module). This process performs also a XML syntax check. When this syntax check fails the complete process stops. The FTP adapter wants to read the file (with the error) again and again.
When we have 10 files in the directory and the first one is in error, the adapter does'n process the other 9 anymore!!
Quality of service is: Exactly Once.
Thanx
RonFelix / Ron,
In the Seebuger FTP adapter, I have
Module Key - exit
Parameter Name - JNDIName
Paramter Valu - deployedAdapters/SeeXIFTP/shareable/SeeXIFTP
JNDIName, should I be replacing this with some other name. I'm trying to get Seeburger FTP to work and in the messaging monitor, I see the message as passed to Module Processor but it does go anywhere from there.
Can one you throw some light on this...what to expect from this definition.
Thank you,
Pam -
When we need Seeburger AS2 & FTP?
Hi,
when we can make use of Seeburger AS2 and FTP?what are the differences?advantages and dis advantages?
And also how can we install AS2 ?I know how to install Seeburger FTP.
thank you,HI,
I think this question is repeating several times ,
read previos questions and close those posts.
When we are integrating the EDI with XI we need seeburger Adapters
See the below links
/people/bla.suranyi/blog/2006/06/08/sap-xi-supports-edifact
/people/william.li/blog/2006/03/17/how-to-get-started-using-conversion-agent-from-itemfield
/people/paul.medaille/blog/2005/11/17/more-on-the-sap-conversion-agent-by-itemfield
http://www.stylusstudio.com/edi/XML_to_X12.html
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/b0b355ae-0501-0010-3b83-8f2bb566fa47
Details on XI EDI adapter from seeburger
EDI with XI
http://www.seeburger.com
http://www.seeburger.com/fileadmin/com/pdf/AS2_General_Overview.pdf
http://www.seeburger.it/fileadmin/it/pdf/2005_04_sapphire_Ferrero_transcript.pdf
http://www.seeburger.com/fileadmin/com/pdf/SEEBURGER_SAP_Adapter_engl.pdf
http://www.seeburger.com/fileadmin/com/pdf/Butler_Group_SEEBURGER_Technology_Audit.pdf
http://www.sap.com/france/company/events/2006/02-01-Automotive-Seeburger.pdf
http://h41123.www4.hp.com/presentations/ISUG/XISeeBurger.ppt
http://www.sap.com/asia/company/events/nwtechdays/presentation/australia-slides/Pre-Built_Integration.pdf
The complete installation manuals can be supplied by the seeburger vendors.
the adapter specific installations you can find in those manuals
Regards
Chilla.. -
Hi,
We need to connect to a VAN system to poll/post files. We have configured the file adapter in FTP mode, but when trying to post/poll for files, we are getting the following error:
2009-10-09 07:17:57 Error File processing failed with An error occurred while connecting to the FTP server '10.159.48.75:21'. The FTP server returned the following error message: 'com.sap.aii.adapter.file.ftp.FTPEx: 501 Syntax errors in parameter. usage: %[recipient id]%[APRF] where either [recipient] or [APRF] can be omitted. (to change your current default SEND relationship). %% (places you in your 'HOME' TR). &['s'|'single'] ('get' command gets single file). &['m'|'multiple'] ('get' command gets multiple files). '. For details, contact your FTP server vendor.
2009-10-09 07:17:57 Error Adapter Framework caught exception: An error occurred while connecting to the FTP server '10.159.48.75:21'. The FTP server returned the following error message: 'com.sap.aii.adapter.file.ftp.FTPEx: 501 Syntax errors in parameter. usage: %[recipient id]%[APRF] where either [recipient] or [APRF] can be omitted. (to change your current default SEND relationship). %% (places you in your 'HOME' TR). &['s'|'single'] ('get' command gets single file). &['m'|'multiple'] ('get' command gets multiple files). '. For details, contact your FTP server vendor.
2009-10-09 07:17:57 Error Transmitting the message to endpoint <local> using connection File_http://sap.com/xi/XI/System failed, due to: com.sap.engine.interfaces.messaging.api.exception.MessagingException: An error occurred while connecting to the FTP server '10.159.48.75:21'. The FTP server returned the following error message: 'com.sap.aii.adapter.file.ftp.FTPEx: 501 Syntax errors in parameter. usage: %[recipient id]%[APRF] where either [recipient] or [APRF] can be omitted. (to change your current default SEND relationship). %% (places you in your 'HOME' TR). &['s'|'single'] ('get' command gets single file). &['m'|'multiple'] ('get' command gets multiple files). '. For details, contact your FTP server vendor..
Can we directly connect to the VAN using FTP in PI, or do we need to do perform some other configuration.
Regards,
ShiladityaHi,
I think you need to use Seeburger's FTP adapter instead of normal FTP adapter.
Read this discussion for more information:
Re: Seeburger FTP Adapter And SAP PI 7.1
Regards,
Ravi Kanth Talagana -
FTP VAN Sender adapter for Sterling Commerce
Hi,
I have configured an FTP VAN sender adapter from Seeburger. I am trying to connect to Sterling Commerce VAN and have configured all the parameters as what have been described in the Seeburger manual for FTP/VAN adapter. I am using a custom script as I need to change the mailbox for the polling to take place. Below is my custom script:
open [@Key=HOST] [@Key=PORT] [@Key=USER] [@Key=PASS]
cwd SD150xxx/
type [@Key=TRANSFERTYPE]
prompt
mget *
close
I configured the comm. channel to use this custom script as:
file:/temp/script.sh
When I activated the comm. channel and open the comm. channel monitor in RWB, all I get is this message:
Adapter has been started. (xxxxx) as node: xxxx
The polling did not take place although I think I've configured them correctly. The file from the mailbox is not being picked up by the comm. channel. Do you have any idea how to get this to work? FYI, I managed to configure the FTP VAN receiver adapter correctly and it worked. I just have problem with the sender channel but I did not know where I went wrong as the status in RWB did not state any error to the configuration. Pls help.
Thanks.Issue solved.
We need to configure something in the Seeburger Workbench-Resource Management-Resources. The incoming channels need to be set to be greater than 0. The Seeburger FTP VAN adapter now works as expected.
Maybe you are looking for
-
Macbook pro 13 inch early 2011 WILL NOT go to SLEEP on ITS OWN.
I am able to close the lid to have it sleep, and manually click the apple>Sleep button to get it to sleep, but with the Energy Saver preferences set for it to sleep at 1 minute it will not allow it to sleep. The display will turn off, but the Light d
-
Mail search not working + Spotlight keeps indexing
I have an old problem that has resurfaced after creating a new user on my Mac. Mail search brings no results and Spotlight is constantly indexing - day in, day out. It never seems to get there. I tried turning my hard drive to private in Spotlight se
-
Using a wired AND wireless network on one machine for better security
It occurs to me that if I could separate my Internet traffic from my LAN traffic, I could have the best security setup, so that machines on my network would only have file sharing enabled for the WIRED connection and I would use the Internet over the
-
Firefox PDF Viewer Displays Specific PDF Incorrectly
I have a PDF hosted on my website that displays incorrectly when loaded in the FireFox PDF viewer. I would like to simply fix the PDF so that it looks correctly. I understand there are ways to circumvent the PDF viewer, but I have not been able to ge
-
Sorry but I can not print from Adobe Digital edition. I bought and down loaded a book and now can not seem to print as the print request is faded out. Can someone help me thanks