SELECT OPTION in logical database PNP

Hi,
when i use ligical database PNP and i'm entering a range in personnel number, in which variables is that stored?
The select option in pnppernr, but this one is initial in start-of-selection and get event.
Is there any othe structure containing the range?
Regards
  Rainer

I think that PNPPERNR is the range.  This sample program works for me.
report zrich_0001.
TABLES: pernr.
parameters: p_check.
start-of-selection.
GET pernr.
write:/ pnppernr.
  check sy-subrc = 0.
Regards,
Rich Heilman

Similar Messages

  • How to hide some select-option of Logical Database in report?

    How to hide select-option of  Logical Database in report?eg . In Logical Database 'PNP' , my code is 'GET  PERNR' , excute the report , select-screen is displayed . I want to hide some select-options , such as PNPPERNR-LOW .
    Edited by: rongrong wang  on Mar 26, 2008 9:31 AM

    U need to write code in initialization as
    initialization.
    loop at screen.
    if screen-name = 'PNPPERNR-LOW'.
    screen-active = '0'.
    modify screen.
    endif.
    if screen-name = 'PNPPERNR-HIGH'.
    screen-active = '0'.
    modify screen.
    endif.
    endloop.

  • Selection screen for logical database PNP..

    hi all,
    I am having a requirement to produce a HR Report where i need to use logical database PNP. Now the issue is i need to supress some of the elements of standard selection screen of PNP and add a couple of fields of mine.
    i have been looking all around and i got few of the below methods.
    its good to use a report category.
    somewhere it says include it in ur program using selection screen block..
    can you please guide me which is the best way and what would be a perfect solution?
    thanks in advance,
    Reena

    Hi reeena,
    1. simple
    2. u want to
      a) add ur own fields
      b) suppress some fields
    3. a) is simple, just add your parameters,
       in your program, and they will appear
       b) use SCREEN logic
    4. just copy paste to get a taste of it
      (it will HIDE the PAYROLL AREA field)
      and add MATNR field
    5.
    report abc.
    TABLES : PERNR.
    PARAMETERS : MATNR LIKE MARA-MATNR.
    AT SELECTION-SCREEN OUTPUT.
      LOOP AT SCREEN.
        IF SCREEN-NAME CS 'ABKRS'.
          SCREEN-INVISIBLE = '1'.
          SCREEN-INPUT = '0'.
          MODIFY SCREEN.
        ENDIF.
      ENDLOOP.
    regards,
    amit m.

  • Selection screen and logical database PNP

    hi all,
    I am having a requirement to produce a HR Report where i need to use logical database PNP. Now the issue is i need to supress some of the elements of standard selection screen of PNP and add a couple of fields of mine.
    i have been looking all around and i got few of the below methods.
    its good to use a report category.
    somewhere it says include it in ur program using selection screen block..
    can you please guide me which is the best way and what would be a perfect solution?
    thanks in advance,
    Reena

    In the Program Attributes, click on the pushbutton 'HR Report Category'.Click on the 'Create' icon in the pop-up  window that comes up. You will get a list of all the available Report Categories. Go through the list & if you don't find one that suits you, select one that is closest & click on the 'Copy As' icon in the menu bar..
    Now, you can remove the unwanted fields & add yours for selection. save it & and attach it to report in the attributes.
    ~Suresh

  • Customizing user selection fields of Logical database PNP

    Dear Gurus,
    I had made a z-copy of payslip program for incorporation of Logo. Now we need to put this report in Enterprise Portal (EP). Now since we would not want any user to view any other person's payslip, I need to disable the selection field (PERNR) for user selection.
    Problem is this field for user selection is coming from standard Logical Database (LDB - PNP) used in the program. So how can I make this field hardcoded as sy-uname and non-modifiable without making z-copy of LDB-PNP.
    Also I wish to harcode Payroll Area writing some code (from table PA000) but again I cannot write this in std. PNP LDB and writing it in driver program will not help.
    Thanks in advance.
    Regards,
    Amit

    Write the highlighted coding in initialization ...
    initialization .
    select single pernr from pa0105
           into pernr-pernr
           where usrid = sy-uname.
    if sy-subrc = 0.
      PNPPERNR-sign = 'I'.
      PNPPERNR-option = 'EQ'.
      PNPPERNR-LOW = pernr-pernr.
      Append PNPPERNR.
    endif.
    loop at screen.
    if screen-name = 'PNPPERNR-LOW' or
    screen-name = 'PNPPERNR-HIGH'.
    screen-input = '0'.
    endif.
    modify screen.
    endloop.
    at selection-screen output.
    loop at screen.
    if screen-name = 'PNPPERNR-LOW' or
    screen-name = 'PNPPERNR-HIGH'.
    screen-input = '0'.
    endif.
    modify screen.
    endloop.

  • Restrict Select-Options for Logical Database field

    The way we restrict select options for custom defined select option fields on selection screen.. can we restrict select options for standard Logical Database fields?
    i.e. report uses PNPCE logical database and has field called PERNR. I want to restrict select options for this PERNR field so that it has options for 'Select single values' only.
    Thanks,
    Falguni
    Edited by: Falguni V on Nov 13, 2010 6:42 AM

    You can user AT SELECTION-SCREEN event, and check whether any record is having high value for PNPPERNR.

  • How to get dynamic select options from logical database?

    Hi,
    in one of my extended reports (means - overwritten standard SAP functionality in Z-namespace) I'm using LDB 'DDF'. I've been requested to validate some of the dynamic selection options (for example - field HKONT at Document level) and to split the logic depending on the particular value(s).
    Tracking what is happened in the LDB program I found that this select option is added as dynamic WHERE clause to the SELECT statement - in a way:
    WHERE bukrs = p_burks AND ... AND
    (where_tab)
    Is there a way to get values of these LDB dynamic select options into my report and if yes - how?
    Thanks in advance.
    Regards,
    Ivaylo Mutafchiev
    Senior SAP Abap Consultant

    Hi,
    Try to use the following fm in your report and check
      call function 'RS_REFRESH_FROM_DYNAMICAL_SEL'
        exporting
          curr_report        = sy-cprog
          mode_write_or_move = 'M'
        importing
          p_trange           = gt_dyn_trange
        exceptions
          not_found          = 1
          wrong_type         = 2
          others             = 3.
    PS please make a whereused of this fm , how it has been used in LDB's to get dynmic selection values

  • Selection screen for HR report with logical database PNP

    Hi All,
       I am writing a HR report. And I use the logical database PNP. Also I create a HR report category for this report. In the report category, I can define the selection screen field. But all these fields are selection option format. My question is How can I add parameters, radiobutton group and checkbox in the selection screen. Thanks.
    Alex

    Hi Alex,
    Sorry for replying so late. Please try this tutorial:
    w w w. s a p t e c h n i c a l. c o m -> tutorials -> ABAP-HR -> Creating HR Report category in PNP logical database
    Sorry, I put it like this, because direct link doens't let me post the answer. Don't know why.
    It can also be something with your custom code in selection screen. Though it works fine for, try to remove COMMENTs and observe the result. Maybe parameters are overlapping somehow. First try this:
    SELECTION-SCREEN begin of BLOCK blk2 WITH FRAME TITLE text-002.
    PARAMETERS RefDate type DATS.
    parameter BFlag type c RADIOBUTTON GROUP grp1.
    PARAMETER FFlag type c RADIOBUTTON GROUP grp1.
    parameters days type i.
    PARAMETERS spvsr like PA0001-MSTBR.
    selection-SCREEN end of BLOCK blk2.
    If that works together with the report category, try to extend it with adding a selection-screen comment, but do this in reversed order (comment goes first and FOR FIELD addition is supplied) like this:
    SELECTION-SCREEN begin of BLOCK blk2 WITH FRAME TITLE text-002.
    PARAMETERS RefDate type DATS.
    SELECTION-SCREEN begin of line.
    SELECTION-SCREEN COMMENT 3(10) text-003 for field bflag.  "FOR FIELD, and goes first
    parameter BFlag type c RADIOBUTTON GROUP grp1.
    SELECTION-SCREEN COMMENT 16(10) text-004 for FIELD fflag.  "here two
    PARAMETER FFlag type c RADIOBUTTON GROUP grp1.
    SELECTION-SCREEN end of line.
    parameters days type i.
    PARAMETERS spvsr like PA0001-MSTBR.
    selection-SCREEN end of BLOCK blk2.
    If still not working, see if text-003 and text-004 are not too long (you expect them to be 10 chars), This may somehow affect selection screen.
    You may also try with setting cursor position explicity by:
    SELECTION-SCREEN begin of line.
    SELECTION-SCREEN POSITION 3.
    SELECTION-SCREEN COMMENT (10) text-003 for field bflag. 
    parameter BFlag type c RADIOBUTTON GROUP grp1.
    SELECTION-SCREEN POSITION 16.
    SELECTION-SCREEN COMMENT (10) text-004 for FIELD fflag.  "here two
    PARAMETER FFlag type c RADIOBUTTON GROUP grp1.
    SELECTION-SCREEN end of line.
    It is really hard to identify where can be a bug as it is working fine for me. Keep trying with different variations, it should finally run with some.
    Regards
    Marcin

  • How to hide selection fields when using logical database PNP

    hi.
    i m using a logical database PNP and report catagory 1PY_DEF in my program.
    but when i execute it , it shows to selection box. one name is period and second is selections.
    but i just want to show only period box selection fields , not the selection box fields.
    how it iz possible.

    HI,
    In my case i haved used the PNP logical database..in the selection box i don't wnat to display Contorling area,Cost Center & Organizational Unit. i have written this code to hide those fields..
    AT SELECTION-SCREEN OUTPUT.
      LOOP AT SCREEN.
        IF screen-name CS 'PNPKOKRS' OR
           screen-name CS 'PNPKOSTL' OR
           screen-name CS 'PNPORGEH'.
          screen-active = '0'.
          screen-invisible = '1'.
          MODIFY SCREEN.
          CLEAR screen.
        ENDIF.
      ENDLOOP.
    Try modify hide the total block instead of individual fields in that block.

  • Selection screen of logical database

    hello all,
    i need to find a way to gray out and put a default value in the selection screen generated by the logical database PNP using the HR Report Category X10002.  how would i be able to do this?
    thanks in advance!

    Hi,
    try that
    NODES pernr.
    INITIALIZATION.
    *<b>gray out</b>
      LOOP AT SCREEN.
        IF screen-name = 'PNPBUKRS-LOW'
        OR screen-name = 'PNPBUKRS-HIGH'.
          screen-input = 0.
          MODIFY SCREEN.
        ENDIF.
      ENDLOOP.
    *default
      pnppernr-low = 4711.
      PNPPERNR-sign = 'I'.
      PNPPERNR-option = 'EQ'.
      append PNPPERNR.
    Andreas

  • ABAP Report Program Logical Database PNP

    I have a ABAP program using the logical database PNP. The report is config to run on MSS using EP. I have added code to capture the Org Unit when it is pass to the program from MSS.  My issue is how do i capture the org unit value that is passed to the program.   I have added code to capture field pnporgeh  in the START OF SELECTION event.   This works great if you are running the program from R3, but none of my edit checking against field pnporgeh works.

    Hi John,
    I am also having same trouble where in i have added a new custom(Z) report in the MSS ->My Staff -> Reporting under report category -> Time Management (MSS). I am not able to find how the value of org unit which is selected on portal screen is passed to report in R/3 which is using PNP logical db.
    I tested in debugging but selection screen parameter PNPORGEH contains nothing.
    Many Thanks in advance for the help.
    Edited by: Ankit Kashyap on Nov 17, 2010 12:40 PM

  • Logical Database PNP

    Hi,
    im using standard logical database PNP. After the user filles the selection screen, i want to manipulate some of the selection fields, but evrything i tried out til now does not change the amount of data i got by GET PERNR. How can i manipulate the selection fields to get results according to the new settings?
    cu
      Rainer

    e.g.the user entered start date 01.01.2005 and enddate 30.11.2005.
    The report shouls always take end of year so i want to manipulate the user entered 30.11.2005 to 31.12.2005.
    Manipulating pn-endda does have no effect.
    So which structers or fields i have to change?

  • How does works default parameters in a program with logical database PNP?

    Hi Friends,
      I have a basic program, i need to filter info with period parameters in a program that uses logical database PNP, but it doesn't work.
      If i use "person selection period" that it's suposed to filter info according to infotype 0001 (as the sap help says), it doesn't work, i use: PNPBEGPS = today and PNPENDPS = today, and the result it's a lot of registers that doesn't meet that criteria.
      Also i tried with: data selection period, today, up to day, current month. And the result it's with the same problem.
      How does works period parameters in a program with logical database PNP?
    This it's the program example, i use the default category.
    REPORT  ZRPHRTEST.
    tables: pernr.
    infotypes: 0001.
    start-of-selection.
    get pernr.
      write: pernr-pernr, p0001-begda, p0001-endda.
    end-of-selection.
    write 'fin'.

    Hi,
    Define pernr table under tables statement then and use GET PERNR event.This get event is followed by End-Of-Selection.
    Syntax: Tables pernr.
                Get pernr.
    Try, activate and test. This should solve your problem.
    Regards,
    Abhijeet

  • To use logical database PNP in class builder

    Hi
    Inside the class builder (SE24), i have a created a method.
    Now while implementing that method, that is between method and endmethod
    statement can i implement logical database PNP or PNPCE.
      If 'yes' how to use it.
      if 'no' what is the other way to implement authorization.
    Pls help me

    Hello,
    assume that the routines GET_ITnnnn are written by yourself. For reading infotypes ABAP Objects provides us with same very helpful classes as shown below:
    * define data
      DATA:
        gif_employee      type ref to if_pt_employee,
        go_employee       type ref to cl_pt_employee,
        gt_infotypes      TYPE tim_tmw_itlist_tab,
        go_control        TYPE REF TO if_pt_td_control,
        go_data           TYPE REF TO if_pt_td_base,
        go_pnnnn          TYPE REF TO if_pt_td_itnnnn,
        gt_p0001          TYPE TIM_P0001_TAB,
        gt_p0002          TYPE TIM_P0002_TAB,
        gt_p0003          TYPE TIM_P0003_TAB.
    start-of-selection.
    GET pernr.
    <b>* Create employee instance</b>
      gif_employee = cl_pt_employee=>get_employee( pernr ).
      go_employee ?= gif_employee.
    <b>* Get master infotypes (0001, 0002)</b>
      CALL METHOD go_employee->get_master_data
        EXPORTING
          im_begda = id_fromdate
          im_endda = id_todate
        IMPORTING
    *      EX_I0000 =
          EX_I0001 = gt_p0001
          EX_I0002 = gt_p0002
    *      EX_I0007 =
    *      EX_I0008 =
    <b>* Append all other required infotypes to itab</b>
      APPEND '0003' TO gt_infotypes.
      CALL METHOD go_employee->get_infotypes
        EXPORTING
          i_itlist      = gt_infotypes
          i_fromdate    = id_fromdate  " start date
          i_todate      = id_todate    " end date
    *      I_FILTER      =
          i_noauthcheck = 'X'
        IMPORTING
          e_result      = gt_infty_request
          e_retcd       = gd_retcd.
    * Please see documentation of parameter e_retcd...
      LOOP AT gt_infty_request INTO go_control.
        go_data = go_control->data.  <b>" get data object</b>
    *   Casting
        TRY.
            go_pnnnn ?= go_data.
          CATCH cx_sy_move_cast_error.
            CONTINUE.
        ENDTRY.
    <b>*   Convert infotype (semi-transparent -> transparent)</b>
        CALL METHOD cl_hr_pnnnn_type_cast=>prelp_to_pnnnn
          EXPORTING
            prelp = lo_pnnnn->prelp
          IMPORTING
            pnnnn = gs_p0003.
        APPEND gs_p0027 TO gt_p0003.
      ENDLOOP.
    The class CL_PT_EMPLOYEE provides us already with very easy access to so-called master infotypes (000, 0001, 0002, 0007 and 0008). All other infotypes can be read using method GET_INFOTYPES.
    Using these classes we have a very convenient and standardized way of accessing all kinds of infotypes.
    Vasanth

  • Logical DataBase PNP - Adding customised Field

    How do everyone,
    I have recently added a new field to the HR master infotype 0001.
    How does one include this new field within the locgical database i.e. PNP, PNPCE
    so that it is automatically included in the report selection screen??
    Any help or suggestions would be much appreciated.
    Andy

    Hi,
    Follow the link.
    Re: Logical Database PNP. HR and Unicode
    Regards
    Rajesh Kumar

Maybe you are looking for

  • How to snap guides in illustrator?

    hello id like to know as in ps we can snap our guide lines to the middle of the canvas and they snap making a nice intersection so we know where the middle of the canvas is,so we can place our object,how can it be done in illustrator?the guide lines

  • ADD push button in selection-screen

    Hi Guys, I have a requirement. In the selection screen on the report, I need a push button "Click". When i "Click"  First Time this it should display all the selection screen Blocks B1,B2,B3 from my selection screen. For second "Click" it should Hide

  • Camera raw is not updating to 8.6 only the DNG converter is, please help

    I have Camera raw 7.1 , it doesn't open Nikon D810 NEF files, I Downloaded the 7.2 , the 8.3 and 8.6 but the package from Adobe only updates my DNG converter and not my camera raw... I tried and tried, nothing is working. I need to get photoshop and

  • Drop-Downs text is wiped out

    RH X 5, webhelp layout To retreive topics that were deleted from a project, I've imported the corresponding output (htm) files. Aside from the red boxes (java script), the topic looks fine only the the text on the drop-down hotspots has been cleared

  • HT201320 Is there a way to "select all" to mark a bunch as read?

    I just got an iPhone 5S and I can add an email account, but when I do (and this isn't the first time) I have to mark hundreds of messages as read!  Is there an easier way than one at a time?  There wasn't a way when I had my iPhone 3G, and it looks l