Selection icons destroyed by AT SELECTION SCREEN OUTPUT

Hello
I have a following code excerpt:
AT SELECTION-SCREEN OUTPUT.
  LOOP AT SCREEN.
    IF screen-name = 'CUSTORDS' OR
       screen-name = 'TRNSORDS' OR
       screen-name = 'REASONCD'.      
      screen-input = '1'.
    ELSEIF ( screen-group1 = 'ONE'
             AND custords = set_x ) OR
           ( screen-group1 = 'TWO'
             AND trnsords = set_x ).
      screen-input = '1'.
    ELSE.
      screen-input = '0'.
    ENDIF.
    MODIFY SCREEN.
  ENDLOOP.
The problem is, that when user gives special selection criteria for select-option field, the icon which appears to the left ('=', '>', etc) next to the affected select-option field inherits the screen-group from the select-option and the coding sets screen-input = 1 for this icon thus destroying it. Instead of an icon a text appears, just like this: '@20\QSelect: Equal to@'.
How can this behavoiur be prevented ?

Add screen-group3 ne 'OPU' to the elseif statement:
ELSEIF ( screen-group1 = 'ONE' and screen-group3 ne 'OPU'
AND custords = set_x ) OR
( screen-group1 = 'TWO' and screen-group3 ne 'OPU'
AND trnsords = set_x ).
Regards
Sridhar

Similar Messages

  • How do I select which bluetooth speakers to play out of? My iPod connects to both kitchen and living room speakers. My old iPod had a selection icon on the now playing screen, but my new one doesn't.

    Hi,
    Our setup
    A new iPod Touch 5 with iOS 8.3.
    Living room speakers that use a Logitech Bluetooth Audio Adapter.
    Kitchen speakers that use an AmazonBasics Bluetooth 4.0 Audio Receiver.
    The iPod connects to both but always wants to play to the kitchen. To play in the living room, we have to unplug the power to the kitchen speakers. Bluetooth settings screen doesn't let you select between Bluetooth connections. All I seem to be able to do is forget the connection.
    We also have an old iPod Touch (not sure of the generation, but it has iOS 6.1.6). On that one, there is a little icon on the now playing screen that would open a little pull-down menu to let you select which Bluetooth connection to use for playing audio.
    I don't see the "select output" icon on the new now playing screen
    Jimmy
    PS the iPod seems very aggressive in connecting. I hear the living room speakers activate when my wife gets out of the car in the driveway. Then as she comes into the living room, the sound switches to the kitchen.

    Thanks, this was the clue I needed to figure it out.
    From Settings you can pull up Control Center.
    In Control Center you can enable "Access from within Apps" (also "Access from Lockscreen")
    Now when I'm playing music, I can swipe up from the bottom and a little control center window slides up. Neat - this is new since my old iPod. On this window, the name of the current Bluetooth connection appears. Tap on that, and a list of connected Bluetooth items appears. I just tap on the one I want to connect to and I am now playing through the speakers I want.
    Jimmy

  • Help Needed in At selection screen output

    Hi Experts,
    I need your help in AT SELECTION SCREEN OUTPUT event. My issue is i have 4 radio button and with each radio button couple of parameters that need to be filled in selection screen of report. My requirement is that sometimes user enters details in second radio button parameters but forgot to change the radio button to second one so kindly suggest a solution so that radio button gets selected as per user input in parameter like if user clicks on certain parameter to enter value then automatically corresponding radio button gets selected.
    Thanks in advance for all your help.

    example from a checkbox in one of my progs..but you can do same approach with radio butts
    parameters p_test as checkbox default abap_on user-command test.
    at selection-screen.
        if sy-ucomm = 'TEST'.
          perform birth_mnth_chck.
        endif.

  • AT SELECTION-SCREEN OUTPUT.

    Hi All,
    I have a selection screen which i need to influence before it is shown in the screen after the transaction is executed.
    I want the user to influence one of the fields in selection screen by an user exit.So if in the user exit the parameter is set by the user ,then only that particular field should be enabled or else it should be disabled.
    I know i can use AT SELECTION-SCREEN OUTPUT.
    but i am not sure that i can influence it with an user exit.
    Could anybody let me know the logic or code to write this.
    It would be very much help full.
    Regards,
    Priya.

    Hi Priya,
    you can make properly for loop at screen. with modify screen..
    it applied for enabled or disabled screen proceed.
    thx,
    s.suresh

  • I Just received the update to iTunes, when I I look at the screen I do not see the normal icons.  When I select movies I do not get the new downloads unless i select the list in the sub file. How do I get backto the old method of seeing and using iTunes??

    I Just received the update to iTunes, when I I look at the screen I do not see the normal icons.  When I select movies I do not get the new downloads unless I select the list in the sub file. How do I get back to the old method of seeing and using iTunes??

    I can tell you that this is some of the absolutely worst customer service I have ever dealt with. I found out from a store employee that when they are really busy with calls, they have third party companies taking overflow calls. One of those companies is Xerox. What can a Xerox call center rep possibly be able to authorize on a Verizon account?  I'm Sure there is a ton of misinformation out there due to this. They don't note the accounts properly or so everyone can see them. I have been transferred before and have asked if they work for Verizon or a third party also and was refused an answer so, apparently they aren't required to disclose that information. I spent a long time in the store on my last visit and it's not just customers that get the runaround. It happens to the store employees as well and it's beyond frustrating.

  • At selection screen output dialog

    how i can make
    i have customer i want when i click enter to get the description.
    the program is dialog , i get always err,and when i put in PBO or PAI.

    Hi Little ,
      What i understand is that you are working on a report and not a module pool.
    If it is a report then you will first have to modify the selection screen , go to SE51 , put in the program name and the screen number ( which is generally 1000) , on the screen add a new I/O box which is for Output only let it be KNA1-NAME1 .
    Now you need to write the code in the event AT SELECTION-SCREEN OUTPUT .
    Here is the sample code for the same
    tables : kna1.
    parameter : kunnr type kna1-kunnr.
    at selection-screen output.
    if not kunnr is initial.
      select single name1 into kna1-name1
        from kna1
        where kunnr =  kunnr.
    endif.
    Hope this helps.
    Regards
    Arun

  • At selection screen output problem

    Hi all,
    I am trying to make a few fields disabled based on the selection of a radio button. I have done it in dialog programming, but in report its not working. Please tell me where i have gone wrong. My code:
    * Selection Screen
    SELECTION-SCREEN BEGIN OF BLOCK b1 WITH FRAME TITLE text-t01.
    PARAMETER : rb_dwld RADIOBUTTON GROUP radi DEFAULT 'X',
                rb_upld RADIOBUTTON GROUP radi.
    SELECTION-SCREEN END OF BLOCK b1.
    SELECTION-SCREEN BEGIN OF BLOCK b2 WITH FRAME TITLE text-t02.
    SELECT-OPTIONS : so_cctrl FOR /dceur/z_crconar-crdt_ctrldsa MODIF ID
                                             sc1 NO INTERVALS OBLIGATORY,
                     so_cusno FOR /dceur/z_crdtlmt-dealer MODIF ID sc1.
    SELECTION-SCREEN END OF BLOCK b2.
    SELECTION-SCREEN BEGIN OF BLOCK b3 WITH FRAME TITLE text-t03.
    SELECT-OPTIONS : so_ctrl1 FOR /dceur/z_crconar-crdt_ctrldsa MODIF ID
                                             sc2 NO INTERVALS OBLIGATORY.
    PARAMETER pa_fname TYPE rlgrap-filename MODIF ID sc2.
    SELECTION-SCREEN END OF BLOCK b3.

    Hi,
    Please check the below code.
    This is one of my requirement.
    * Creation of two blocks with parameter fields for create and update
    SELECTION-SCREEN: BEGIN OF BLOCK b1 WITH FRAME.
    PARAMETER p_create LIKE rlgrap-filename MODIF ID crt.
    SELECTION-SCREEN: END OF BLOCK b1.
    SELECTION-SCREEN: BEGIN OF BLOCK b2 WITH FRAME.
    PARAMETER p_update LIKE rlgrap-filename MODIF ID upt.
    SELECTION-SCREEN: END OF BLOCK b2.
    * Making one parameter field active at a time
    AT SELECTION-SCREEN OUTPUT.
      IF rb_crt = 'X'.                              "CREATE BUTTON IS SELECTED
        PERFORM hide_rb_options.
        CLEAR p_create.
      ELSE.                                         "UPDATE BUTTON IS SELECTED
        PERFORM hide_rb_options.
        CLEAR p_update.
      ENDIF.
    *&      Form  hide_rb_options
    FORM hide_rb_options .
      IF rb_crt = 'X'    .
        LOOP AT SCREEN.
          CASE screen-group1.
            WHEN 'CRT'.
              screen-active = 1.
              MODIFY SCREEN.
            WHEN 'UPT'.
              screen-active = 0.
              MODIFY SCREEN.
          ENDCASE.
        ENDLOOP.
      ELSE.
        LOOP AT SCREEN.
          CASE screen-group1.
            WHEN 'UPT'.
              screen-active = 1.
              MODIFY SCREEN.
            WHEN 'CRT'.
              screen-active = 0.
              MODIFY SCREEN.
          ENDCASE.
        ENDLOOP.
      ENDIF.
    ENDFORM.                    " hide_rb_options
    May it helps you.
    Regards.
    DS.

  • At-selection screen output and radio button together

    Hi all,
    I want to make  a screen with radio buttons and a drop down menu on selection screen as soon as I check any button and click on Open from drop down menu the output should come according to the button cheked but the problem is that desired output is not coming.
    Please see if something could be done.
    Thanks,
    Shweta

    Hi,
    Here is the code see y it didnt responds,
    I made ZMENU2 in SE41 with Menu bar as OPEN , also activated buttons BACK and EXIT.
    tables : sscrfields.
    CONSTANTS : buttonselected TYPE c LENGTH 1 VALUE 'X'.
    DATA: ok_code LIKE sy-ucomm.
    SELECTION-SCREEN BEGIN OF BLOCK frame1 WITH FRAME TITLE text-001.
    SELECTION-SCREEN ULINE /1(60).
    PARAMETERS: first RADIOBUTTON GROUP rad DEFAULT 'X',
    second RADIOBUTTON GROUP rad,
    third RADIOBUTTON GROUP rad,
    fourth RADIOBUTTON GROUP rad,
    fifth RADIOBUTTON GROUP rad.
    SELECTION-SCREEN END OF BLOCK frame1.
    AT SELECTION-SCREEN OUTPUT.
      SET PF-STATUS 'ZMENU2'.
      If first = buttonselected and ok_code = 'OPEN'..
             WRITE 'You selected first button'.
        ELSEIF second = buttonselected and ok_code = 'OPEN'..
            WRITE 'You selected second button'.
        ELSEIF third = buttonselected and ok_code = 'OPEN'.
            WRITE 'You selected third button'.
        ELSEIF fourth = buttonselected and ok_code = 'OPEN'.
            WRITE 'You selected fourth button'.
        ELSEIF fifth = buttonselected and ok_code = 'OPEN'.
            WRITE 'You selected fifth button'.
        ELSEIF ok_code ='BACK'.
           LEAVE PROGRAM.
        ELSEIF ok_code ='EXIT'.
          LEAVE PROGRAM.
      ENDIF.

  • At Selection-screen output event

    Hi
    can any one give me some examples for at selection-screen output event
    with regards
    nagaraj
    Moderator message: please search for available information/documentation.
    Edited by: Thomas Zloch on Nov 8, 2011 12:13 PM

    Thanks Benedict
    Creating Module %_S_KOSTL and write our own logic to bring the parameter id value of Cost center from User profiles is NOT possible in program RM06BF00,  screen 1000.
    We can do that in Copied program of RM06BF00 ..which is the very last option.
    I wanted to do that with User-exits or BADI or Enhancement spot etc...which i Couldn't do it so far...
    The alternate might be Zprog and Ztcode or an SNOTE..
    if you ALL think its NOT possible with User-exits or BADI or Enhancement spot or SNOTE etc..Then i will close this Thread...
    Please let me know ASAP...
    Thanks
    Govi

  • AT SELECTION-SCREEN OUTPUT not working!

    Hi,
    I am useing the statement AT SELECTION-SCREEN OUTPUT to disable some input fields based on a check box(PR_FILE).however when I execute the program the changes on the screen are not reflected!I have written the AT SELECTION-SCREEN OUTPUT stmt immediately after SELECTION-SCREEN stmt .
    Defination for the screen elements is  as  follows:
    SELECT-OPTIONS s_plants FOR  ls_selected_plant-plant
                                                         NO INTERVALS.
    SELECTION-SCREEN BEGIN OF BLOCK filesel WITH FRAME TITLE text-012.
    PARAMETERS pr_file TYPE xfeld .
    PARAMETER : pr_path LIKE rlgrap-filename .
    SELECTION-SCREEN END OF BLOCK filesel.
    AT SELECTION-SCREEN OUTPUT.
      IF pr_file = 'X'.
        LOOP AT SCREEN.
          IF screen-name = 's_plants'.
            screen-input    = '0'.
            MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
      ELSE.
        LOOP AT SCREEN.
          IF screen-name = 'pr_path'.
            screen-input    = '0'.
            MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
      ENDIF.
    Can anybody suggest what wrong i have done??

    You need to use the User Command for the checkbox and the Modificaiton ID (Group) for the fields.
    Try like this:
    TABLES: VBRP.
    SELECT-OPTIONS S_PLANTS FOR VBRP-WERKS NO INTERVALS MODIF ID GP1.
    SELECTION-SCREEN BEGIN OF BLOCK FILESEL WITH FRAME TITLE TEXT-012.
    PARAMETERS PR_FILE TYPE XFELD USER-COMMAND USR1.
    PARAMETER : PR_PATH LIKE RLGRAP-FILENAME MODIF ID GP2 .
    SELECTION-SCREEN END OF BLOCK FILESEL.
    AT SELECTION-SCREEN OUTPUT.
        IF PR_FILE = 'X'.
          LOOP AT SCREEN.
            if screen-group1 = 'GP1'.
              SCREEN-active = '0'.
              MODIFY SCREEN.
            ENDIF.
          ENDLOOP.
        ELSE.
          LOOP AT SCREEN.
            IF SCREEN-group1 = 'GP2'.
              SCREEN-active = '0'.
              MODIFY SCREEN.
            ENDIF.
          ENDLOOP.
        ENDIF.
    Regards,
    Naimesh Patel

  • At selection- screen output issue

    Hi,
    I have a issue regarding at selection-screen output event with radio buttons, 
    Fields are like,
    Block B1
      RB1
    Block B2
    RB2
       field 1 (Check box)
       field 2 (Check box)
    User can select one radio button at a time. If the user clicks on radio button RB1 then fields under Block B2 will be disabled. If user click on RB2 field 1 and fields 2 will be input enabled. Could you please give the solution asap
    Note: Radio buttons are in different selection screen blocks.

    Check this code -
    *SELECTION-SCREEN BEGIN OF BLOCK B WITH FRAME.
    *PARAMETERS:
    *Pi1 TYPE C  RADIOBUTTON GROUP G1 DEFAULT 'X',
    *Pi2 TYPE CHAR25,
    *Pi3 TYPE C  RADIOBUTTON GROUP G1,
    *Pi4 TYPE CHAR25.
    *SELECTION-SCREEN END OF BLOCK B.
    *PARAMETERS check AS CHECKBOX.
    *PARAMETERS show_all AS CHECKBOX USER-COMMAND flag.
    *SELECTION-SCREEN BEGIN OF BLOCK b1 WITH FRAME.
    *PARAMETERS: ip1(10) TYPE c,
               ip2(10) TYPE c,
               ip3(10) TYPE c.
    *SELECTION-SCREEN END OF BLOCK b1.
    *SELECTION-SCREEN BEGIN OF BLOCK b2 WITH FRAME.
    *PARAMETERS: ip4(10) TYPE c MODIF ID bl2,
               ip5(10) TYPE c MODIF ID bl2,
               ip6(10) TYPE c MODIF ID bl2.
    *SELECTION-SCREEN END OF BLOCK b2.
    *AT SELECTION-SCREEN OUTPUT.
    LOOP AT SCREEN.
       IF show_all <> 'X' AND
          screen-group1 = 'BL2'.
          screen-active = '0'.
       ENDIF.
       MODIFY SCREEN.
    ENDLOOP.
    Regards,
    Amit Khare
    reward all helpful replies.

  • At selection-screen output probelm

    Hi ,
    I am using 4 parameters in the selection screen . I am entering data in the 3 input fields. Then I am doing concatenate 3 fileds data into the 4 th field in the event AT SELECTION-SCREEN OUTPUT, bur my problem is  When ever i click ENTER , then only 4th field is updating. With out ENTER key , Is it possible update 4th filed.
    regards,
    ramajay reddy

    Hi,
    This is not possible without a user action on the screen, unless your fields are drop down lists, check box or radiobutton respectively, Reason is that the SAP Screen processing will not trigger the PAI event unless there is a user action on the screen like pushing a button, radiobutton , checkbox or selecting a value from a dropdown list. And hence PBO will not get triggered either. Thus entering value in input fields and pressing the tab key is not enough. The user must press 'Enter' if the PAI--PBO should be triggered.
    Pressing 'Enter' is much more user friendly and convinient than adding a button/radiobutton/checkbox on the selection screen to update other fields on the selection screen as in your scenario.
    regards,
    Advait

  • At selection-screen output and  at selection-screen on

    Hi Experts,
    I had coded in both at selection-screen output for disabling input of certain fields and at selection-screen for validation like this:
    AT SELECTION-SCREEN output.
      IF p_amt = 'X'.
        LOOP AT SCREEN.
          CASE screen-name.
            WHEN 'P_AMT'.
              screen-input = '1'.
            WHEN 'P_TST'.
              screen-input = '1'.
            WHEN 'P_B4C'.
              screen-input = '1'.
            WHEN 'P_AFC'.
              screen-input = '1'.
            WHEN 'P_COM'.
              screen-input = '1'.
            WHEN 'P_COM1'.
              screen-input = '1'.
            WHEN 'P_COM2'.
              screen-input = '1'.
            WHEN OTHERS.
              screen-input = '0'.
          ENDCASE.
          MODIFY SCREEN.
        ENDLOOP.
      ENDIF.
      IF p_amt = 'X'.
        LOOP AT SCREEN.
          CASE screen-name.
            WHEN 'P_AMT'.
              screen-input = '1'.
            WHEN 'P_TST'.
              screen-input = '1'.
            WHEN 'P_B4C'.
              screen-input = '1'.
            WHEN 'P_AFC'.
              screen-input = '1'.
            WHEN 'P_COM'.
              screen-input = '1'.
            WHEN 'P_COM1'.
              screen-input = '1'.
            WHEN 'P_COM2'.
              screen-input = '1'.
            WHEN OTHERS.
              screen-input = '0'.
          ENDCASE.
          MODIFY SCREEN.
        ENDLOOP.
      ENDIF.
      IF p_pdf = 'X'.
        LOOP AT SCREEN.
          CASE screen-name.
            WHEN 'P_PDF'.
              screen-input = '1'.
            WHEN 'P_TST'.
              screen-input = '1'.
            WHEN 'P_PATH'.
              screen-input = '1'.
            WHEN OTHERS.
              screen-input = '0'.
          ENDCASE.
          MODIFY SCREEN.
        ENDLOOP.
      ENDIF.
      IF p_afc = 'X'.
        LOOP AT SCREEN.
          CASE screen-name.
            WHEN 'P_TST'.
              screen-input = '1'.
            WHEN 'S_FID-LOW' OR 'S_FID-HIGH'.
              screen-input = '0'.
            WHEN 'S_ORG-LOW' OR 'S_ORG-HIGH'.
              screen-input = '0'.
            WHEN 'S_OFF-LOW' OR 'S_OFF-HIGH'.
              screen-input = '0'.
            WHEN 'S_DAT-LOW' OR 'S_DAT-HIGH'.
              screen-input = '0'.
          ENDCASE.
          MODIFY SCREEN.
        ENDLOOP.
      ENDIF.
    AT selection-screen on block b5.
    if p_tst is initial.
      message text-016 type 'E'.
    endif.
    AT selection-screen on block b2.
    if p_amt ne 'X' and p_pdf ne 'X'.
    if s_fid is initial and s_org is initial.
    message text-000 type 'E'.
    endif.
    if s_dat is initial.
    message text-000 type 'E'.
    endif.
    endif.
    when i comment out at selection-screen validations the input is disabled for the screen fields as set, else the validations are executed first.
    Any solution for this???
    Thanks in advance.

    AT SELECTION-SCREEN
    Syntax
    AT SELECTION-SCREEN selscreen_event.
    Effect
    This statement defines event blocks for different events selscreen_event that are triggered by the ABAP runtime environment during selection screen processing.
    Selection screen events occur immediately before sending a selection screen and after certain user actions on a displayed selection screen. They assist in selection screen processing in the ABAP program.
    AT SELECTION-SCREEN is triggered at least twice during actions on selection screens that are linked into another selection screen as a subscreen - first for the linked selection screen itself, and then for the linking selection screens.
    Note
    The event blocks after AT SELECTION-SCREEN are implemented internally as procedures. Declarative statments in these event blocks create local data.

  • At selection screen output not responding

    Hi ppl,
    I've 4 selection options in my screen. however I just need user to insert only 1 of the 4 for searching. Therefore i included 4 radio buttons. when user select <i>rbf</i>, <i>sfileno</i> will activer and other 3 will be grayed out, when user select <i>rbi</i>, <i>sidnum</i> will active and other will not be active and so forth. You can see the codes below.
    However, during the program running, I found out when i select <i>rbf,</i> the other select options fields - <i>sfileno</i>, <i>sidnum</i> n <i>scompsno</i> are not inactive/grayed. It is the same when I seledt the other radio button. I just seem that i receive no response from the program. What have i done wrong here. please help. TQ
    SELECTION-SCREEN BEGIN OF BLOCK frm1 WITH FRAME TITLE text-t01 .
    SELECT-OPTIONS : sfileno FOR zlic_masterdb-nofailpermohonan modif id f01
                      sidnum FOR zcustomer-idnumber modif id i01,
                      sconame FOR zcustomer-contactname modif id n01,
                      scompsno FOR zcom_compdhdr-compsno modif id c01.
    PARAMETERS: rbf RADIOBUTTON GROUP g1 ,
    rbi RADIOBUTTON GROUP g1,
    rbn RADIOBUTTON GROUP g1,
    rbc RADIOBUTTON GROUP g1.
    SELECTION-SCREEN END   OF BLOCK frm1.
    INITIALIZATION.
    sfileno = '00001'.
                     AT SELECTION-SCREEN OUTPUT
    AT SELECTION-SCREEN OUTPUT.
      LOOP AT SCREEN.
      CHECK SCREEN-GROUP1 = 'f01' OR
    SCREEN-GROUP1 = 'i01' OR
    SCREEN-GROUP1 = 'n01' OR
    SCREEN-GROUP1 = 'c01'.
    IF rbf = 'X'.
      IF SCREEN-GROUP1 EQ 'f01'.
        SCREEN-ACTIVE = 1.
      ELSEIF SCREEN-GROUP1 EQ 'i01'.
        SCREEN-ACTIVE = 0.
      ELSEIF SCREEN-GROUP1 EQ 'n01'.
        SCREEN-ACTIVE = 0.
      ELSEIF SCREEN-GROUP1 EQ 'c01'.
        SCREEN-ACTIVE = 0.
      ENDIF.
    ELSEIF rbi = 'X'.
      IF SCREEN-GROUP1 EQ 'i01'.
        SCREEN-ACTIVE = 1.
      ELSEIF SCREEN-GROUP1 EQ 'f01'.
        SCREEN-ACTIVE = 0.
      ELSEIF SCREEN-GROUP1 EQ 'n01'.
        SCREEN-ACTIVE = 0.
      ELSEIF SCREEN-GROUP1 EQ 'c01'.
        SCREEN-ACTIVE = 0.
      ENDIF.
    ELSEIF rbn = 'X'.
      IF SCREEN-GROUP1 EQ 'n01'.
        SCREEN-ACTIVE = 1.
      ELSEIF SCREEN-GROUP1 EQ 'f01'.
        SCREEN-ACTIVE = 0.
      ELSEIF SCREEN-GROUP1 EQ 'i01'.
        SCREEN-ACTIVE = 0.
      ELSEIF SCREEN-GROUP1 EQ 'c01'.
        SCREEN-ACTIVE = 0.
      ENDIF.
    ELSEIF rbc = 'X'.
      IF SCREEN-GROUP1 EQ 'c01'.
        SCREEN-ACTIVE = 1.
      ELSEIF SCREEN-GROUP1 EQ 'f01'.
        SCREEN-ACTIVE = 0.
      ELSEIF SCREEN-GROUP1 EQ 'n01'.
        SCREEN-ACTIVE = 0.
      ELSEIF SCREEN-GROUP1 EQ 'i01'.
        SCREEN-ACTIVE = 0.
      ENDIF.
    ENDIF.
    MODIFY SCREEN.
    continue.
    ENDLOOP.

    hi Enzo
    Check my sample code
    TABLES: eban,
            SSCRFIELDS.
    SELECTION-SCREEN BEGIN OF SCREEN 100 TITLE title.
    SELECTION-SCREEN BEGIN OF BLOCK b1 WITH FRAME TITLE text-t01.
    PARAMETER:rad1 RADIOBUTTON GROUP rad USER-COMMAND frad1 DEFAULT 'X',
              rad2 RADIOBUTTON GROUP rad .
    SELECTION-SCREEN END OF BLOCK b1.
    SELECTION-SCREEN BEGIN OF BLOCK b2 WITH FRAME TITLE text-t02.
    PARAMETER: mtr AS CHECKBOX MODIF ID g3 USER-COMMAND chk1,
               p_matnr TYPE eban-matnr MODIF ID g1,
               sloc AS CHECKBOX MODIF ID g3 USER-COMMAND chk2,
               str_loc TYPE eban-lgort MODIF ID g4.
    SELECTION-SCREEN END OF BLOCK b2.
    SELECTION-SCREEN BEGIN OF BLOCK b3 WITH FRAME TITLE text-t03.
    SELECT-OPTIONS: matnr1 FOR eban-matnr MODIF ID g2.
    SELECTION-SCREEN END OF BLOCK b3.
    SELECTION-SCREEN PUSHBUTTON /20(10) name USER-COMMAND UCOM.
    SELECTION-SCREEN END OF SCREEN 100.
    name = 'FETCH'.
    title = 'Test Report'.
    CALL SELECTION-SCREEN '100'.
    TYPE-POOLS slis.
    * declaration of internal tables and work areas to be used
    DATA: BEGIN OF it_pr OCCURS 0,
          banfn TYPE eban-banfn,
          bnfpo TYPE eban-bnfpo,
          loekz TYPE eban-loekz,
          statu TYPE eban-statu,
          ekgrp TYPE eban-ekgrp,
          matnr TYPE eban-matnr,
          werks TYPE eban-werks,
          lgort TYPE eban-lgort,
          preis TYPE eban-preis,
          peinh TYPE eban-peinh,
          END OF it_pr.
    DATA: BEGIN OF it_mat OCCURS 0,
          matnr TYPE eban-matnr,
          END OF it_mat.
    *DATA:BEGIN OF ITAB1 OCCURS 0,
      DATA: l_answer.
    DATA: it_fieldcat TYPE slis_t_fieldcat_alv,
          wa_fieldcat LIKE LINE OF it_fieldcat,
          it_event TYPE slis_t_event,
          wa_event TYPE slis_alv_event.
    * declaration of variables to be used
    DATA: r_ucomm TYPE sy-ucomm,
          mat_no TYPE eban-matnr,
          len TYPE i VALUE 1,
          count TYPE i VALUE IS INITIAL,
          iflag TYPE i VALUE IS INITIAL,
          iflag1 TYPE i VALUE 0.
    DATA :pr_id TYPE sy-repid,
    rt_extab TYPE slis_t_extab.
    INITIALIZATION.
      pr_id = sy-repid.
    probably it would sol;ve ur problem
    regards
    ravish
    <b>plz dont forget to reward points if helpful</b>

  • At selection screen output problem when a field is obligatory

    Hi All,
    I have two radiobuttons on the selection screen and when I select first radiobutton one screen should display and the other should not be displayed and vice-versa. It is working fine if I do not have a mandatory field.I am pasting my code here.Can anyone please help me how to handle this situation when we have some mandatory fields on one of these screens.
    TABLES : mara,marc.
    SELECTION-SCREEN BEGIN OF BLOCK b1 WITH FRAME TITLE text-001.
    PARAMETERS : p_meth1 RADIOBUTTON GROUP g1 USER-COMMAND g1,
                 p_meth2 RADIOBUTTON GROUP g1.
    SELECTION-SCREEN END OF BLOCK b1.
    SELECTION-SCREEN BEGIN OF BLOCK matnr WITH FRAME TITLE text-002.
    SELECTION-SCREEN SKIP 1.
    SELECT-OPTIONS : so_matnr FOR marc-matnr MODIF ID m1 obligatory.
    SELECTION-SCREEN SKIP 1.
    SELECT-OPTIONS : so_werks FOR marc-werks MODIF ID m1 .
    SELECTION-SCREEN END OF BLOCK matnr.
    SELECTION-SCREEN BEGIN OF BLOCK file WITH FRAME TITLE text-003.
    SELECTION-SCREEN SKIP 1.
    PARAMETERS: p_fpath TYPE ibipparms-path MODIF ID m2 LOWER CASE.
    SELECTION-SCREEN END OF BLOCK file.
    SELECTION-SCREEN BEGIN OF BLOCK date WITH FRAME TITLE text-004.
    SELECTION-SCREEN SKIP 1.
    PARAMETERS : p_date TYPE datuv.
    SELECTION-SCREEN END OF BLOCK date.
    AT SELECTION-SCREEN OUTPUT.
    LOOP AT SCREEN.
    CASE screen-group1.
    WHEN 'M1'.
    IF p_meth1 = 'X'.
    screen-active = 1.
    ENDIF.
    IF p_meth2 = 'X'.
    screen-active = 0.
    ENDIF.
    WHEN 'M2'.
    IF p_meth2 = 'X'.
    screen-active = 1.
    ELSE.
    screen-active = 0.
    ENDIF.
    IF p_meth1 = 'X'.
    screen-active = 0.
    ENDIF.
    ENDCASE.
    MODIFY SCREEN.
    ENDLOOP.
    Thanks in advance
    Sandeep

    Obligatory fields with your requirement will not work, reason : The GUI checks obligatory fields before passing the control back to the program (i.e Before triggering the PAI )
    If you check for empty fields and give appropriate error message in the PAI, the program will not allow you to switch to the other radio button until you fill something in the fields because the moment you select a radiobutton, it will validate the field and issue the error message.
    So it is like a catch 22 situation.
    All you can really do is to check see which radio button is clicked and then do your processing. Also make sure to assign a user command to the radiobutton and query it in the AT SELECTION SCREEN and based on the radiobutton selected, decide which fields should be validated.
    " Additon...
    INITIALIZATION  " Default values
    p_meth1 = 'X'.
    AT SELECTION-SCREEN.  " General PAI
    if p_meth1 EQ 'X'.
    "validate fields for meth1.
    elseif p_meth2 EQ 'X'.
    " validate fields for meth2.
    endif.
    regards,
    Advait

Maybe you are looking for

  • How to make project across two DVDs with one DVD menu

    Hi! I'm working on a large project (3 hours of video with about 10 chapters, over 50 pictures in a playlist, and special feature chapter) and wondering is it possible to make an project across 2 or more DVDs, but to have menu only on first one? I'd l

  • TS3989 how can i see photos in iCloud?

    how can i see the photos from photo stream on icloud.com?

  • OpenGL via Solaris Studio

    Hello all! Present: Oracle Solaris 10 9/10 x86 and Solaris Studio 12.2 Whether there is at whom skeleton for С\С ++ OpenGL application. I can not find the decision - how to begin

  • Can't delete OR find Mal/Phish-A

    Hello Everyone, I hope you can help me with a challenge I am having. Currently I have Sophos Anti-Virus Home Edition version 9.2.4 on my Mac (OS X Yosemite 10.10.3) Reason for the post is I have a virus (Mal/Phish-A) that keeps coming up and I am not

  • Convert iMovie to Real Media (.rm) file

    I need to create a Real Media (.rm) video for my class but I haven't found a way to convert the video I created in iMovie to that format. Is there a way? I've tried flip4mac and looked at ffmpegX, but I don't think they solve my problem. Thanks for a