Selection screen field not accepting 0 as a value

i have declared a field in the selection screen as
SELECT-OPTIONS:  s_level    FOR  crmm_territory-level_id .
and this field will comprise of values from 0-9. but when im executing the report this field is not accepting 0 as a value, instead it is treating it as a blank and providing me all the values for s_level from 0-9.
its working fine with any other value and is displaying their respective values for 1-9
only problem is when i give the value as zero.
also in the debugger i tried to IF s-level[] is not initail...its showing it as initial
while i have provided it a value of 0.
thanks.

Hello Divya,
If you are giving 0 in the select-options....
if that field is numeric... it means that it is inital.
If that field is character... then it will display the result accordingly.
Check with the data element of the reference field.
Reward If Helpful
Regards
Sasidhar Reddy Matli.

Similar Messages

  • Selection screen field not working in Query

    Hi Gurus!
    I have a small problem with one of my query that I just created for finding status of our customers. I have a code section which handles it all . The problem is that I ahve a user field called "Check date" which I ahve used in selection screen as well as the layout, when I put a value in this field in the selection screen the report dosent give any output " NO data to display" but when I leave it open it does give me the out put with the saem check date as I ahd entered earlier in my selection screen.
    I am not sure where my selection code is working wrong . Could anyone please help me out please.
    DATA: ls_vakpa LIKE vakpa.
    DATA old_date LIKE sy-datum.
    old_date = key_date - num_days.
    status = 'ACTIVE'.
    check_date = old_date.
    * (If I entere this field (check_date) with any date
    *  and run it does not give me output and without
    * entry it dioes give output.
      SELECT SINGLE * FROM vakpa INTO ls_vakpa
          WHERE kunde = kna1-kunnr
       AND audat > old_date.
          IF sy-subrc <> 0.
        SELECT SINGLE * FROM vakpa INTO ls_vakpa
            WHERE kunde = kna1-kunnr
          AND audat < old_date.
          IF sy-subrc = 0.
          ls_audat = ls_vakpa-audat.
          ls_vbeln = ls_vakpa-vbeln.
        ELSE.
          CLEAR ls_audat.
          clear ls_vbeln.
        ENDIF.
        status = 'INACTIVE'.
      ELSE.
        ls_audat = ls_vakpa-audat.
        ls_vbeln = ls_vakpa-vbeln.
      ENDIF.
    Edited by: Rob Burbank on Apr 7, 2010 12:08 PM

    DATA: ls_vakpa LIKE vakpa.
    DATA old_date LIKE sy-datum.
    old_date = key_date - num_days.
    status = 'ACTIVE'.
    check_date = old_date.
    if old_date is initial.
       old_date = key_date - num_days.
       check_date = old_date.
    endif.
      SELECT SINGLE * FROM vakpa INTO ls_vakpa
          WHERE kunde = kna1-kunnr
    *      AND audat > old_date.
        AND audat > check_date.
      IF sy-subrc <> 0.
        SELECT SINGLE * FROM vakpa INTO ls_vakpa
            WHERE kunde = kna1-kunnr
    *        AND audat < old_date.
          AND audat < check_date.
        IF sy-subrc = 0.
          ls_audat = ls_vakpa-audat.
          ls_vbeln = ls_vakpa-vbeln.
        ELSE.
          CLEAR ls_audat.
          clear ls_vbeln.
        ENDIF.
        status = 'INACTIVE'.
      ELSE.
        ls_audat = ls_vakpa-audat.
        ls_vbeln = ls_vakpa-vbeln.
      ENDIF.

  • Selection Screen - Field dehighlight

    Hello All,
    How can i make an Selection screen field not as an Input field.
    The field is a parameter P_GJAHR which will always be set to 2005. So, i would like to see FY 2005 on the selection screen field as dehighlighted.
    Would be glad if views are provided on this.
    Regards,
    - PSK

    PARAMETERS : P_GJAHR LIKE BKPF-GJAHR MODIF ID SG1.
    AT SELECTION-SCREEN OUTPUT.
      LOOP AT SCREEN.
        IF SCREEN-GROUP1 = 'SG1'.
          SCREEN-INPUT = '0'.
          MODIFY SCREEN.
        ENDIF.
      ENDLOOP.
    Hope this helps,
    Erwan.

  • Selection screen fields are not getting detected in an infoset in code

    Hi All,
    I am developing an infoset query using logical database 'PNPCE'. I am facing problem while writing a validation on selection screen fields on an infoset query at infoset code level.
    The fields that are under program specific selection are determined at runtime with variables viz. SP$00001, SP$00002 etc. There are actually select options on selection screen of an infoset query.
    So I cannot write a direct  code on these fields as they do not exist at infoset level and hence cannot be detected.
    I want to put down a validation that if user does not select anything on selection-screen and executes the query, then he should get a pop-up message 'Narrow down your search...' and he should go back to selection screen again.
    Is there any alternative way to achieve this?

    hi,
    Your Screen resolution is more in the system that's why while creating it was fine and while executing it was gone after the next field.
    so you better create a frame and place that inside it or you can change cols size  in the properties about the columns you want

  • Selection screen field

    Hi,
    A field in the selection screen of the report program should be disabled by default.
    I have written the logic for the same in at selection-screen output.
    If the user enters value in another field in selection screen,the field should be enabled for input.
    When the user executes the program,o/p is displayed.
    When the user clicks back button in the o/p screen,the field is again shown in disabled mode as the event at selection screen o/p is being triggered.
    The field should be enabled when the user cliks back button in the o/p.
    How to achieve this? => by writing the code. And we cannot do that for you.
    Moderator Message:
    Also,
    Total Questions:  141 (102 unresolved)
    suggests that you do not get back to the people who spend time on your issues. Be a responsible forum member by acknowledging people's time and effort.
    Edited by: kishan P on Nov 11, 2010 4:16 PM

    Hi,
    If i understood correctly you requirement you just have to make use of a global variable i.e. gv_enabled, which will be used as flag. Before disable the field in at selection-screen output event, check if gv_enabled is initial. When you enable the field for input, for the first time just move 'X' to gv_enabled.
    Best Regards
    George Zervas

  • Selection screen field problem

    Hello experts..
    i have a selection screen , in that i have a field   s_bwart for mseg-bwart.
    some times the user will input the data in the field and sometimes he wont. we have fixed movement types combination like
    11-21 , 13-24 , 13-56 , 101-543 , 101-544 etc.
    if the user did not input any thing in the selection screen , i am populating s_bwart in at-selection screen event with all the mvt types. after executing the report when user presses the back button to come to the selection screen, there the s_bwart field is containing all the mvt types in single values ie in the select options screen. So the user dont want that, if he comes back nothing should be there in the selection screen field s_bwart if he has not inputted anything. if he inputs only 11 mvt type then when he comes back after executing the report he should see only 11 in the select screen field ie s_bwart. Please send the replies on how to solve the problem.

    hi,
    in ur program try to display values for users in START-OF-SELECTION event as it triggers after the selection screen displayed for users. if user doesn't give any input then display default values in this event. and also create a variable
    for ex:
    data: ws_flag type c,
             p_value type i.
    after u display default values for users in selection screen assign the flag as ' X '
    ws_flag = 'X'.
    before leaving ur program based on flag try to do like this.
    if ws_flag = ' X '.
        clear s_data. // s_data is the select options for u.
    else.
         s_data = p_value. // the value which user gave in selection screen as i/p.
    endif.
    if helpful reward some points.
    with regards,
    Suresh Aluri.

  • Regarding Selection-Screen Field Display

    Hi All,
    I have issues with Selection-Screen field display.
    The Actual issue is i had declared a selection screen field as: <b>s_exgen FOR embk-exgen</b>.
    <b>EMBK-EXGEN</b> is actually <b>20</b> Char length field.
    But in output display it is being shown as <b>18</b> Char field though i can type in all <b>20</b> characters.
    But <b>display</b> restricted to <b>18</b> Characters only.
    Can anybody give me the solution for the same!
    Thanks in advance.
    Thanks & Regards,
    Prasad.

    Hi,
    You can decrease the visible length of the field but you can not increase more than database field length. check SAP help on this :
    select-options: s_exgen FOR embk-exgen VISIBLE LENGTH 5.
    ... VISIBLE LENGTH vlen
    Effect
    This addition allows you to shorten the visible length of the corresponding screen field on the selection screen to vlen.
    Variant 2
    SELECT-OPTIONS sel FOR (f).
    Additions as in variant 1.
    Effect
    In this variant, (f) must be a field containing the name of the actual reference field at runtime. The system creates the LOW and HIGH fields as character fields with length 45. However, their appearance on the selection <b>screen is inherited from the reference field whose name is contained in field f at runtime.</b>
    Regards
    Appana

  • F4 Help for the selection screen field

    Hi Gurus,
    I have to display F4 help for a selection screen field. i am using following code:
        CALL FUNCTION 'F4IF_INT_TABLE_VALUE_REQUEST'
             EXPORTING
                  retfield        = 'CODE'
                  dynpprog        = lw_repid
                  dynpnr          = sy-dynnr
                  VALUE_ORG       = 'S'
             TABLES
                  value_tab       = gi_text
                 field_tab       = li_fields_tab
                  return_tab      = pi_return_tab
             EXCEPTIONS
                  parameter_error = 1
                  no_values_found = 2
                  OTHERS          = 3.
    My internal table gi_emp has two fields CODE & TEXT. When i select 1 particular value, it returns the CODE value in the pi_return_tab table.
    But my requirement is i have to capture the corresponding TEXT value for the Returned CODE. Ex: following is the F4 help being displayed: -
    001    test
    001    test1
    but is i select code 001(First Value), i also need to capture it's corresponding Text value. In return table pi_return_tab i have only Code value.
    Please help me out.
    Note: Based on return code i can't search into the internal table gi_code, because as shown in the example, code has multiple text.

    Sachin,
    I think this is what you need. The following code will return the key and the text (OR any other columns), if both columns are in the selection screen the selected values (both columns) will also be passed to the corresponding parameters. If you only need the text to be in the return table and not passed to the selection screen then set the parameter for text with NO-DISPLAY option.
    REPORT zktest01 .
    DATA :
      BEGIN OF value_tab OCCURS 0,
        field  LIKE e070-trkorr,
        text   LIKE e07t-as4text,
      END OF value_tab.
    DATA: t_fldtab LIKE dfies OCCURS 0 WITH HEADER LINE,
          t_rettab LIKE ddshretval OCCURS 0 WITH HEADER LINE,
          t_dynmap LIKE dselc OCCURS 0 WITH HEADER LINE.
    PARAMETERS : p_field  LIKE value_tab-field,
                 p_text   LIKE value_tab-text. "NO-DISPLAY.
    INITIALIZATION.
      t_fldtab-tabname   = 'VALUE_TAB'.
      t_fldtab-fieldname = 'FIELD'.
      t_fldtab-langu     = 'E'.
      t_fldtab-position  = 1.
      t_fldtab-offset    = 0.
      t_fldtab-fieldtext = 'Key'.
      t_fldtab-reptext   = 'Key'.
      t_fldtab-leng      = 20.
      t_fldtab-intlen    = 20.
      t_fldtab-outputlen = 20.
      t_fldtab-datatype  = 'CHAR'.
      t_fldtab-inttype   = 'C'.
      t_fldtab-headlen   = 20.
      t_fldtab-keyflag   = 'X'.
      t_fldtab-lowercase = ' '.
      APPEND t_fldtab.
      t_fldtab-tabname   = 'VALUE_TAB'.
      t_fldtab-fieldname = 'TEXT'.
      t_fldtab-position  = 2.
      t_fldtab-offset    = 20.
      t_fldtab-fieldtext = 'Text'.
      t_fldtab-reptext   = 'Text'.
      t_fldtab-leng      = 60.
      t_fldtab-intlen    = 60.
      t_fldtab-outputlen = 60.
      t_fldtab-headlen   = 60.
      t_fldtab-keyflag   = ' '.
      t_fldtab-lowercase = ' '.
      APPEND t_fldtab.
      value_tab-field = '101'.
      value_tab-text = 'dddd'.
      APPEND value_tab.
      value_tab-field = '202'.
      value_tab-text = 'aaaa'.
      APPEND value_tab.
      t_dynmap-fldname = 'FIELD'.
      t_dynmap-dyfldname = 'P_FIELD'.
      APPEND t_dynmap.
      t_dynmap-fldname = 'TEXT'.
      t_dynmap-dyfldname = 'P_TEXT'.
      APPEND t_dynmap.
    AT SELECTION-SCREEN ON VALUE-REQUEST FOR p_field.
      CALL FUNCTION 'F4IF_INT_TABLE_VALUE_REQUEST'
           EXPORTING
                retfield        = 'FIELD'
                dynpprog        = 'ZKTEST01'
                dynpnr          = '1000'
                dynprofield     = 'P_FIELD'
                value_org       = 'S'
           TABLES
                field_tab       = t_fldtab
                value_tab       = value_tab
                return_tab      = t_rettab
                dynpfld_mapping = t_dynmap
           EXCEPTIONS
                parameter_error = 1
                no_values_found = 2
                OTHERS          = 3.
      IF sy-subrc EQ 0.
      ENDIF.
    START-OF-SELECTION.
    Jeffrey Satriadi

  • Displaying error message while entering selection screen fields

    Moderator message: don't offer points
    hi experts...
    i generated a report.
    in that report, the selection screen fields are plant and material type..
    now my rqmt  is like this :
    if user enters any plant except '8210' in  the selection screen, then a pop up should appear like.. enter 8210 plant only, and the cursor should remain in the same screen allowing user to enter correct plant.
    and then same with the case of material type also..user should enter 'mcfe' material type only..
    im using message classes like this:
    if so_bwkey-low ne '8210' or so_bwkey-high ne '8210'.
      message i000(zts).
      endif.
    if so_mtart-low is not initial and so_mtart-high is not initial and so_mtart-low ne 'mcfe'
       or so_mtart-high ne 'mcfe'.
      message i001(zts).
      endif.
    with this logic, when i enter plant..it is prompting
    1) enter plant 8210 only..
    and then when i press enter key it is again prompting
    2)enter material type mcfe only..
    but iam not entering material type here..
    i want to get 2nd error message if and only if i enter material type..
    help me regarding this issue..
    <<text removed>>
    thanks in advance,
    harini.
    Edited by: Matt on Feb 9, 2009 10:14 AM

    Hi,
    Use Error type message in SELECTION SCREEN EVENT.It will place the cursor in the relevant Field.
    At SELECTION-SCREEN ON SO_BWKEY-Low.
    if so_bwkey-low ne '8210' .
    message E000(zts).
    endif.
    At SELECTION-SCREEN ON SO_BWKEY-HIGH.
    if  so_bwkey-high ne '8210'.
    message E000(zts).
    endif.
    At SELECTION-SCREEN ON so_mtart-LOW.
    if so_mtart-low is not initial and  so_mtart-low ne 'mcfe' .
    message E001(zts).
    endif.
    At SELECTION-SCREEN ON so_mtart-HIGH.
    if so_mtart-high is not initial 
    and so_mtart-high ne 'mcfe'.
    message E001(zts).
    endif.
    This will resolve the issue..
    Regards,
    Gurpreet

  • Disable a selection screen field

    Hi All,
    I have 2 selection screen fields if enter any value in field 1 another field should be disabled with out pressing enter on the selection screen. am able to do disable by pressing enter onc i give the value in field 1.
    Please do needful.
    Thanks in advance.
    Thanks,
    Ramu.

    Hi Ramu,
    As far as i know its not possible without pressing enter/Execute or any action on selection screen.
    This is because report programming is event driven. So without any event i don't think we can achieve this.
    Probably u can search in SDN/Google as well. If u r lucky enough some one has found some thing for you. But at the same time don't forget to update this thread if u find some thing:-)
    Thanks,
    Vinod.

  • Validating a selection-screen field

    Hi all,
    I am Anil.can any body explains me how to validate a selection-screen field for the following scenario?
    I have customer nos ranging from 100-1000.among them i dont have any sales orders for the customers who are in between 150-250.I have sales order(VBELN) as select-options and Plant(WERKS) as Parameter on the selection-screen.I want to validate these fields without hardcaode.How can i do that?Please send me the complete code.
    I am not getting how to validate a field  which is declared as parameter?
    regards and thanks in advance.
    Anil.

    Make sure that u are validating against the header table.
    say eg if u wnat t validate matnr in marc, then do as below.
    SELECT-OPTIONS: s_matnr FOR  marc-matnr.                  "Material No
    AT SELECTION-SCREEN.
    *Validate material no details
      PERFORM validate_matno.
    FORM validate_matno.
    DATA: v_matnr LIEK mara-matnr.
      SELECT SINGLE matnr INTO v_matnr
             FROM <b>mara</b>
             WHERE matnr IN s_matnr.
      IF sy-subrc NE 0.
        MESSAGE i128.
        LEAVE LIST-PROCESSING.
      ENDIF.
    ENDFORM.
    Dont select from marc.
    Hope this is clear.

  • How to link a search help to a selection screen field

    Hi All,
    I am using field PKWRG from PA0017 table in selection screen. I need F4 help there as in Tcode PA30 . But this field does not have value table or check table. However, it has a search help attached 'TRV_PKWRG' .
    But, I donot know how to assign a search help to a selection screen field. Please help.
    Regards,
    Nibha

    Hello,
    Fetch all the data which from the table which you want to show in the search help and pass the value to the FM
    F4IF_INT_TABLE_VALUE_REQUEST and the selection-screen event must be
    at selection-screen on value request parameter or selection option variable.
    BCALV_TEST_FULLSCREEN
    BCALV_TEST_FULLSCREEN_CALLS
    BCALV_TEST_FULLSCREEN_PRINT
    BCALV_TEST_FULLSCREEN_STATUS
    BCALV_TEST_GRID
    BCALV_TEST_GRID_DRAG_DROP
    BCALV_TEST_GRID_EDITABLE
    BCALV_TEST_GRID_EVENTS
    BCALV_TEST_GRID_INDEX
    BCALV_TEST_GRID_TOOLBAR
    BCALV_TEST_HIERSEQ_LIST
    BCALV_TEST_LIST
    BCALV_TEST_LIST_PRINT
    BCALV_TEST_LIST_STATUS
    BCALV_VERIFY_DTYPES_D0100_F01
    BCSMENUF01
    BDLCOF10
    BDLDVI10
    BDLTREDF

  • Selection-screen fields validation for dialog

    Hello ABAP Gurus
    Requirements: this is a report wherein , depending upon the correct select-options , user will pick some field values from table and some will be entered by the user in the next se51 custom screen for creation of a record in a ztable .
    the problem is :without validating select-options values , it calls the se51 screen 100.
    How to keep the cursor at the selection-screen field until & unless user enters the correct i/p s .if i/p are correct then only it should call screen 100 otherwise remain in the selection screen only .
    *& Report ZSD_REP_QUOT_BANK_CREATE *
    REPORT ZSD_REP_QUOT_BANK_CREATE NO STANDARD PAGE HEADING LINE-SIZE 255.
    TABLES: VBAK,VBAP,VBRK,ZSD_TABL_QOTBANK,MARA,KONV.
    DATA: OK_CODE LIKE SY-UCOMM,
    SAVE_OK_CODE LIKE SY-UCOMM,
    WA_ITAB LIKE ZSD_TABL_QOTBANK,
    ANSWER TYPE C,
    COPIED ,
    STS TYPE N,
    EMGRP LIKE MARA-EXTWG,
    QTY LIKE ZSD_TABL_QOTBANK-QTY,
    UPRICE LIKE ZSD_TABL_QOTBANK-UPRICE,
    TOT LIKE ZSD_TABL_QOTBANK-TOT,
    INO LIKE VBAP-POSNR.
    SELECTION-SCREEN BEGIN OF BLOCK b1 WITH FRAME TITLE text-000.
    SELECT-OPTIONS: S_QTNO FOR ZSD_TABL_QOTBANK-QTNO
    NO INTERVALS NO-EXTENSION OBLIGATORY,
    S_ITNO FOR ZSD_TABL_QOTBANK-ITNO
    NO INTERVALS NO-EXTENSION OBLIGATORY.
    S_MATNO FOR ZSD_TABL_QOTBANK-MATNO
    NO INTERVALS NO-EXTENSION. "
    SELECTION-SCREEN END OF BLOCK b1.
    AT SELECTION-SCREEN.
    SELECT SINGLE VBTYP
    INTO VBAK-VBTYP
    FROM VBAK
    WHERE VBELN IN S_QTNO.
    IF SY-SUBRC EQ 0 AND VBAK-VBTYP NE 'B'.
    MESSAGE I005(ZQOTBANK).
    SET CURSOR FIELD S_QTNO-LOW.
    SUBMIT (SY-REPID) VIA SELECTION-SCREEN.
    ENDIF.
    CLEAR WA_ITAB.
    SELECT SINGLE QTNO ITNO
    INTO WA_ITAB
    FROM ZSD_TABL_QOTBANK
    WHERE QTNO IN S_QTNO
    AND ITNO IN S_ITNO.
    IF SY-SUBRC EQ 0.
    MESSAGE I001(ZQOTBANK).
    SET CURSOR FIELD S_QTNO-LOW.
    SET CURSOR FIELD S_ITNO-LOW.
    SUBMIT (SY-REPID) VIA SELECTION-SCREEN.
    ENDIF.
    *START-OF-SELECTION.
    END-OF-SELECTION.
    CALL SCREEN 0100.
    *& Module STATUS_0100 OUTPUT
    text
    MODULE STATUS_0100 OUTPUT.
    SET PF-STATUS '0100'.
    SET TITLEBAR '0100'.
    ZSD_TABL_QOTBANK-QTNO = S_QTNO-LOW.
    SELECT SINGLE BUKRS_VF VKORG VTWEG SPART KUNNR ERDAT BNDDT
    KNUMV
    INTO (ZSD_TABL_QOTBANK-CCODE,
    ZSD_TABL_QOTBANK-SORG,
    ZSD_TABL_QOTBANK-DISTCHAN,
    ZSD_TABL_QOTBANK-DIV,
    ZSD_TABL_QOTBANK-CUSTNO,
    ZSD_TABL_QOTBANK-QTDAT,
    ZSD_TABL_QOTBANK-QTVALDAT,
    VBAK-KNUMV)
    FROM VBAK
    WHERE VBELN IN S_QTNO
    AND VBTYP = 'B'.
    IF SY-SUBRC EQ 0.
    SELECT SINGLE KWMENG POSNR MATNR
    INTO (QTY , INO , ZSD_TABL_QOTBANK-MATNO)
    FROM VBAP
    WHERE VBELN IN S_QTNO.
    SELECT SINGLE EXTWG
    INTO EMGRP
    FROM MARA
    WHERE MATNR EQ ZSD_TABL_QOTBANK-MATNO.
    ZSD_TABL_QOTBANK-ITNO = INO.
    ZSD_TABL_QOTBANK-EMATGRP = EMGRP.
    ZSD_TABL_QOTBANK-QTY = QTY.
    SELECT SINGLE KBETR
    INTO UPRICE
    FROM KONV
    WHERE KNUMV = VBAK-KNUMV
    AND KPOSN = INO
    AND KSCHL = 'PR00'.
    ENDIF.
    ZSD_TABL_QOTBANK-UPRICE = UPRICE.
    TOT = QTY * UPRICE .
    ZSD_TABL_QOTBANK-TOT = TOT .
    CLEAR: QTY, UPRICE, TOT.
    QTY = ZSD_TABL_QOTBANK-CGL_QTY.
    UPRICE = ZSD_TABL_QOTBANK-CGL_UPRICE .
    TOT = QTY * UPRICE .
    ZSD_TABL_QOTBANK-CGL_TOT = TOT .
    CLEAR: QTY, UPRICE, TOT.
    QTY = ZSD_TABL_QOTBANK-BHEL_QTY.
    UPRICE = ZSD_TABL_QOTBANK-BHEL_UPRICE .
    TOT = QTY * UPRICE .
    ZSD_TABL_QOTBANK-BHEL_TOT = TOT .
    CLEAR: QTY, UPRICE, TOT.
    QTY = ZSD_TABL_QOTBANK-BHEL_QTY.
    UPRICE = ZSD_TABL_QOTBANK-BHEL_UPRICE .
    TOT = QTY * UPRICE .
    ZSD_TABL_QOTBANK-BHEL_TOT = TOT .
    CLEAR: QTY, UPRICE, TOT.
    QTY = ZSD_TABL_QOTBANK-ALSTOM_QTY.
    UPRICE = ZSD_TABL_QOTBANK-ALSTOM_UPRICE .
    TOT = QTY * UPRICE .
    ZSD_TABL_QOTBANK-ALSTOM_TOT = TOT .
    CLEAR: QTY, UPRICE, TOT.
    QTY = ZSD_TABL_QOTBANK-SIEMENS_QTY.
    UPRICE = ZSD_TABL_QOTBANK-SIEMENS_UPRICE .
    TOT = QTY * UPRICE .
    ZSD_TABL_QOTBANK-SIEMENS_TOT = TOT .
    CLEAR: QTY, UPRICE, TOT.
    QTY = ZSD_TABL_QOTBANK-TELK_QTY.
    UPRICE = ZSD_TABL_QOTBANK-TELK_UPRICE .
    TOT = QTY * UPRICE .
    ZSD_TABL_QOTBANK-TELK_TOT = TOT .
    CLEAR: QTY, UPRICE, TOT.
    QTY = ZSD_TABL_QOTBANK-OTH_QTY.
    UPRICE = ZSD_TABL_QOTBANK-OTH_UPRICE .
    TOT = QTY * UPRICE .
    ZSD_TABL_QOTBANK-OTH_TOT = TOT .
    CLEAR: QTY, UPRICE, TOT.
    ENDMODULE. " STATUS_0100 OUTPUT
    *& Module USER_COMMAND_0100 INPUT
    text
    MODULE USER_COMMAND_0100 INPUT.
    CASE OK_CODE.
    WHEN 'SAVE'.
    INSERT ZSD_TABL_QOTBANK.
    IF SY-SUBRC EQ 0.
    MESSAGE I000(ZQOTBANK).
    COMMIT WORK.
    CALL SELECTION-SCREEN 1000.
    ELSE.
    MESSAGE E001(ZQOTBANK).
    CALL SELECTION-SCREEN 1000.
    ENDIF.
    ENDCASE.
    ENDMODULE. " USER_COMMAND_0100 INPUT
    *& Module EXIT_COMMAND INPUT
    text
    MODULE EXIT_COMAND INPUT.
    SAVE_OK_CODE = OK_CODE.
    CLEAR OK_CODE.
    CASE SAVE_OK_CODE.
    WHEN 'CANCEL'.
    CALL FUNCTION 'POPUP_TO_CONFIRM'
    EXPORTING
    TITLEBAR = 'Quotation Bank Entry'
    TEXT_QUESTION = 'Do you want to Cancel ?'
    TEXT_BUTTON_1 = 'Yes'
    TEXT_BUTTON_2 = 'No'
    DEFAULT_BUTTON = '2'
    IMPORTING
    ANSWER = ANSWER.
    IF ANSWER = '1'.
    LEAVE PROGRAM.
    ELSE.
    CALL SELECTION-SCREEN 1000.
    ENDIF.
    WHEN 'EXIT'.
    CALL FUNCTION 'POPUP_TO_CONFIRM'
    EXPORTING
    TITLEBAR = 'Quotation Bank Entry'
    TEXT_QUESTION = 'Do you want to Exit ?'
    TEXT_BUTTON_1 = 'Yes'
    TEXT_BUTTON_2 = 'No'
    DEFAULT_BUTTON = '2'
    IMPORTING
    ANSWER = ANSWER.
    IF ANSWER = '1'.
    LEAVE PROGRAM.
    ELSE.
    CALL SELECTION-SCREEN 1000.
    ENDIF.
    ENDCASE.
    ENDMODULE. " EXIT_COMMAND INPUT
    Thnx in Advance

    Put the statement
    CALL SCREEN 100
    in the event <b>AT SELECTION-SCREEN</b> and NOT in <b>END-OF-SELECTION</b>.
    Regards,
    Subramanian V.

  • Selection screen fields in query

    experts
    i have created a query with 5 selection screen fields, now i want to change the order of the fields in the selection screen.
    Earlier:
    Material
    order
    delivery
    qty
    amount
    Now i want
    order
    material
    delivery
    amount qty
    In sq01 i tried but there are possibility to change the output fields but not selection screen field sequence.

    Hi,
    In SQ01, enter the query name and click on the change button.
    Next click on the next screen (top left) arrow button until you reach Change query xxxxx: Selections.
    Here under the column No  enter the number like 1,2,3, 4 ... against the checked fields that want to see in order. Then save the query.
    Regards,

  • Selection screen fields in which values have been entered

    Hi All,
    Is there any standard function module which enables us to determine which fields on the selection screen have values entered for them. In other words, I wish to determine which selection screen fields are no longer initial.
    Thanks and Regards,
    Vidya.

    Hi,
    Why cant you simply use in this way?
    if sel_screen_field1[] is not initial.  "for selet-options
    endif.
    if sel_screen_field1 is not initial.  "for parameters
    endif.
    is it not suitable for your case?
    //Kothand

Maybe you are looking for

  • Where is "Share button"on YouTube?

    Where is "share button" on YouTube (cited in adobe Muse tutorial 'Katie's Cafe" to create an embedded YouTube video for play on Muse website.)??

  • How to show the region multiple times on the same page

    Hi, I have a PL/SQL Dynamic Content region which creates a report with custom layout using pl/sql web toolkit. The stored procedure takes the parameter and creates report. Can I display the same region multiple times by calling it from loop with diff

  • How to change date format

    Can anyone help me with this, Please? I have a form with start date and end date and the date format I am getting is YYYY-MM-DD. But I would like to change it to MM-DD-YYYY format. How do I achieve this?? When I went to JFPREAMBLE_1, i see it reads:

  • Photo Stacking in iPhoto

    Hi, Does anyone know if this is possible, if so how to do it? Regards.

  • How to use a LabVIEW tab constant?

    Hello LabVIEW gurus, The LabVIEW version in use: 2013 SP1 My OS: Win 7 When I use a tab constant, it only moves one space. Why is that? I would expect to see 5-6 white spaces Any pointers will be appreciated greatly. Thank you. Attachments: TabConsta