Send print spool to different system

Dear Expert,
Due to user authorization constrain, I would like to generate a report from another system, and the report will be saved in another system.
Say,
System A execute RFC to system B to generate a report, ie. the report is executed in system B,
but the print spool of the report is in system A.
Is this possible ?
Edited by: Kokwei Wong on May 16, 2008 8:20 AM

Hi Kokwei,
Try using FM RFC_ABAP_INSTALL_AND_RUN.
Check the sample code in url,
http://books.google.co.in/books?id=6YU5-HqV5vIC&pg=PA347&lpg=PA347&dq=RFC_ABAP_INSTALL_AND_RUN+example&source=web&ots=8OjkobQjZF&sig=soHvxtD90vPmjqjL58dXwi9FXqI&hl=en#PPT380,M1
Hope this helps
Thanks
Lakshman

Similar Messages

  • BD16 to send cost centers to different system

    Hi,
    I want to send cost centers from one system to another using BD16. BD16 works only when both the systems have same controlling area. In my case I have different controlling area in both the systems. Is there anyway I can send IDOC from one system to another?
    Thanks
    Chhavi

    Hi
    Please search help.sap.com for ALE mechanism.. I guess such cases are handled by ALE
    br, Ajay M

  • Print priview and spool print output are different

    Hi Friends,
    there is problem with purchase order print priview and spool print output are different.
    mean : in me23n .. for a perticular po .. in po priview one amount value is 120 coming..
    when i am giving print with spool.. the amount value is showing
    is  443..why it is showing wrong..
    this is for perticular output type.
    why perticular values are showing different in print view and
    spool print.
    regards,

    make this setting change:
    in SPAD > In the menu Settings -> Spool System
    In the others tab check the first check box in the Output Controller block, SAVE and exit

  • Received error 1920 service print spooler failed to start verify that you have sufficient privileges to start system services

    In installing Adobe XI Pro this error message was received "error 1920 service print spooler failed to start verify that you have sufficient privileges to start system services". What does this mean and how can I get this installed?

    It very much means what it says - you do not have sufficient administrative privileges and something on your system is blocking the (virtual) PDF printer driver from being installed.
    Mylenium

  • 'Send Print Request' button can send paystub output to R/3 print spool:

    Hi
    Portal Experts
    Current state of the SAP environment  on ECC 5.0 and EP 6  SP17
    'Send Print Request' button can send paystub output to R/3 print spool:
    When I clicked on ‘send print request’, I expected a printout to my default printer but didn’t get one.   If the dialog user has the 'print immediate' option turned off, their paystub will spool up in R/3. When a user clicks on the printer ICON within Adobe, they get to choose their printer and know that it will go straight to the printer.  This could be confusing to R/3 dialog users.
    Any solution,How to change the option from spool to print immediate.
    Thanks
    Vanteru

    Facing the same problem.
    Please let me know if you have found a solution.

  • Purchase order print priview and spool print output are different.

    Hi Friends,
    there is problem with purchase order print priview and spool print output are different.
    mean : in me23n .. for a perticular po .. in po priview the TAX VALUES value is 120 coming..
    when i am giving print with spool.. the amount value is showing  TAX VALUE
    is 443..why it is showing wrong..
    this is for perticular output type.
    why TAX VALUES are showing different in print view and
    spool print.
    help me.
    regards,

    Hi Neil,
    thanks for your reply.
    but the valiadtions are happening in standard functional module PRICING.
    it is realted script(medruck)...but there is no code point for spool or printer side..
    and the issue is realted one PO OUTPUT TYPE..
    it is sap standard debugging... when i am debugging the functional module PRICING.
    the values are coming dynammically.
    help me.
    regards,

  • I need help to send idocs from 1 client to another , both in different systems

    Hi all,
    I am new to Idoc. I am trying to use idoc to send some table records of a custom table created in client 800 to client 020, both clients are in different systems.
    I found examples of same scenario but for both clients in same system..
    what changes should I make then to be able to send idoc .
    any link showing step by step instructions would be great.
    Thank you.

    1. If you insist on keying in Pr; use the color or chroma key. If you want a quality product use a compositor like AE to do your keying.
    2. Export to Encore

  • Error Sending proxy from 2 different business system to PI

    Hi All,
    We are trying to send the proxy to XI system from 2 different business systems. One is ECC and other is POSDM, It is successfully sent from ECC but when sending the same from POSDM we are getting following error
    "An error occurred when determining the business system (LD_ERROR)"
    We checked the RFC SAPSLDAPI, LCRSAPRFC they are in place. We have also created the type H connection from POSDM pointing to PI and from PI pointing to POSDM.
    And the In sxmb_adm of POSDM system the role is maintained as Application System and IS_URL parameter is pointing to PI, but still we are getting same error.
    Could you all experts please provide you valuable input why this error is coming and how to resolve this?
    Thanks
    Ankit

    Hi Soni,
    check your config in sxmb_adm > Integration Engine Configuration. Also run S_BCE_68001402 and check for locked users.
    Try refreshing the cache in SXI_CACHE in that system.
    Check if u r executing the report in the same client in which u have done all the settings.
    Also make sure that u have included the commit work statement after the Execute Asynchronous method call.
    regards,
    ganesh.

  • Sending e-mails between different SAP-Systems with SMTP

    Hello,
    I want to send e-mails between two different internal SAP-Systems. I already configured SMTP in both systems but ist not possible to send an e-mail from system A to system B.  I've got following error message:
    Cannot process message; no node determined for <sapuser>:
    Thanks in advance & best regards,
    Christoph

    Hi Christoph,
    but it is possible that the email for user from System B is also available in the system itself(transaction so01) and not only in his outlook inbox?
    As the email is sent from System A. It will be available under SOST of system A.
    As user in System B is receiving the email, it will be appearing in users inbox.
    Check with Mail server administrator on where to enable SMTP relaying for IP address of SAP server.
    Hope this helps.
    Regards,
    Deepak Kori

  • Msg print spooler sub system app has encountered a problem and needs to close. how to fix.

    don' know how to correct print spooler problem.  Using XP Pro & HP Officejet Pro All in One L7590.  Nothing new on computer.  Will not print standard data either, but did print the test print from HP.  Details are "sz App name: spoolsv.exe, sz App ver: 5.1.2600.6024; sz Mod name: hpz3r58a.dll, sz Mod Ver: 61.63.263.23, offset: 00104a8d.  Have also had msg "need to install printer, but all printers on control panel are "ready".  Tried HP diagnostic. Am not technically experienced but have been using computer for years.

    Hi there,
    Try downloading and running the print and scan doctor located here:
    http://h10025.www1.hp.com/ewfrf/wc/document?docname=c03275041&cc=us&dlc=en&lc=en
    It can fix a lot on its own and if not give a better idea of what is going on.
    Best of Luck!
    You can say thanks by clicking the Kudos Star in my post. If my post resolves your problem, please mark it as Accepted Solution so others can benefit too.

  • Printing ZPL (Zebra) data to printer spooler without character conversion

    Hi all,
    We are printing shipping labels from UPS, with a process where we recive the ZPL label code directly from UPS, and we just need to pass the data to the printer to get the labels. We have already implemented this with Fedex and some custom labels, and it works perfectly. The problem with the UPS label data is that it contains non-printable characters (in the MaxiCode data field). When passed to the SAP printer spooler (see code example below), the data gets corrupted because SAP interprets these non-printable characters as printer control codes.
    I have verified this by saving the ZPL data to a local file, before printing it through the SAP spooler. I then print this raw data and compare the output with the labels printed from the spooler. The MaxiCode (the big 2D barcode) is different in these labels. UPS has also tested the labels, and rejected them because of incorrect data in the barcode.
    For printing, we are using printers defined as type "PLAIN", but I also tried using the "LZEB2" device type with the same result. The error we see in the spooler entry is this:
    Print ctrl S_0D_ is not defined for this printer. Page 1, line 2, col. 2201
    Print output may not be as intended
    The printer ctrl code differs, depending om the label. I have examined the spooler data in "raw" mode, and there is always an ASCII character 28 (hex 1C) in front of the characters that SAP think are control codes, and this is why I think these non-printable characters are the reason for the problems.
    This is the function module I use to print the ZPL data (and as stated above, this works fine for Fedex and custom labels). The ZPL data is converted to binary format before passed to the function module, but I also tried to send the data in text format with another FM, but the result is the same. I have experimented with the "codepage" parameter, and this one gives the least amount of errors, and some labels actually get through without errors. But still at least 50% of the labels gets corrupted, with log entries like above.
    CALL FUNCTION 'RSPO_SR_WRITE_BINARY'
          EXPORTING
            handle           = lv_spool_handle
            data             = lv_label_line_bin
            length           = lv_len
            codepage         = '2010'
          EXCEPTIONS
            handle_not_valid = 1
            operation_failed = 2
            OTHERS           = 3.
    Does anyone know if there is a way to send data to the spooler without character conversion or interpretation of printer control codes? Or is there any other smart way to get around this problem?
    /Leif

    I do a more direct output to the spooler, to avoid any issues with the WRITE statement and SAP's report output processing. At the same time, I insert line breaks so that the output is easy to debug in the spooler if needed. Also included is the code to to detect the escape code (ASCII #28) and to insert a control code ZZUPS in its place (you can skip this for Fedex). Here's a simplified example, but please note this is for a Unicode system, some minor changes is required in a non-Unicode system.
    CONSTANTS: lc_spcode TYPE c LENGTH 5 VALUE 'ZZUPS',
               lc_xlen TYPE i VALUE 5.
       DATA: lv_print_params TYPE pri_params,
             lv_spool_handle TYPE sy-tabix,
             lv_name TYPE tsp01-rq0name,
             lv_spool_id TYPE rspoid,
             lv_crlf(2) TYPE c,
             lv_lf TYPE c,
             lstr_label_data TYPE zship_label_data_s,
             lv_label_line TYPE char512,
             lv_label_line_bin TYPE x LENGTH 1024,
             lv_len TYPE i,
             ltab_label_data_255 TYPE TABLE OF char512,
             ltab_label_data TYPE TABLE OF x,
             lv_c1 TYPE i,
             lv_c2 TYPE i,
             lv_cnt1 TYPE i,
             lv_cnt2 TYPE i,
             lv_x(2) TYPE x.
       FIELD-SYMBOLS: <n> TYPE x.
       lv_crlf = cl_abap_char_utilities=>cr_lf.
       lv_lf = lv_crlf+1(1).
       lv_name = 'ZPLLBL'.
    CALL FUNCTION 'RSPO_SR_OPEN'
         EXPORTING
           dest                   = i_dest
           name                   = lv_name
           prio                   = '5'
           immediate_print        = 'X'
           titleline              = i_title
           receiver               = sy-uname
    *      lifetime               = '0'
           doctype                = ''
         IMPORTING
           handle                 = lv_spool_handle
           spoolid                = lv_spool_id
         EXCEPTIONS
           device_missing         = 1
           name_twice             = 2
           no_such_device         = 3
           operation_failed       = 4
           OTHERS                 = 5.
       IF sy-subrc <> 0.
         RAISE spool_open_failed.
       ENDIF.
    LOOP AT i_label_data INTO lstr_label_data.
         CLEAR ltab_label_data_255.
         SPLIT lstr_label_data-label_data AT lv_lf INTO TABLE ltab_label_data_255.
         LOOP AT ltab_label_data_255 INTO lv_label_line.
           IF lv_label_line NE ''.
             lv_len = STRLEN( lv_label_line ).
    *       Convert character to hex type
             lv_c1 = 0.
             lv_c2 = 0.
             DO lv_len TIMES.
               ASSIGN lv_label_line+lv_c1(1) TO <n> CASTING.
               MOVE <n> TO lv_x.
               IF lv_x = 28.
                 lv_cnt1 = 0.
                 lv_label_line_bin+lv_c2(1) = lv_x.
                 lv_c2 = lv_c2 + 1.
                 DO lc_xlen TIMES.
                   ASSIGN lc_spcode+lv_cnt1(1) TO <n> CASTING.
                   MOVE <n> TO lv_x.
                   lv_cnt2 = lv_c2 + lv_cnt1.
                   lv_label_line_bin+lv_c2(2) = lv_x.
                   lv_c2 = lv_c2 + 2.
                   lv_cnt1 = lv_cnt1 + 1.
                   lv_len = lv_len + 1.
                 ENDDO.
               ELSE.
                 lv_label_line_bin+lv_c2(2) = lv_x.
                 lv_c2 = lv_c2 + 2.
               ENDIF.
               lv_c1 = lv_c1 + 1.
             ENDDO.
    *       Print binary data to spool
             lv_len = lv_len * 2. "Unicode is 2 bytes per character
             CALL FUNCTION 'RSPO_SR_WRITE_BINARY'
               EXPORTING
                 handle                 = lv_spool_handle
                 data                   = lv_label_line_bin
                 LENGTH                 = lv_len
               EXCEPTIONS
                 handle_not_valid       = 1
                 operation_failed       = 2
                 OTHERS                 = 3.
             IF sy-subrc <> 0.
               RAISE spool_write_failed.
             ENDIF.
           ENDIF.
         ENDLOOP.
       ENDLOOP.
       CALL FUNCTION 'RSPO_SR_CLOSE'
         EXPORTING
           handle = lv_spool_handle.
       IF sy-subrc <> 0.
         RAISE spool_close_failed.
       ENDIF.

  • Jobs stay in queue and keep printing until you cancel them--then stops the print spooler...why?

    My Printer: HP Photosmart C309a
    My  Laptop: HP G71 series
    Operating System: Windows 7 (64 bit) but runs a lot of stuff on 32 bit
    Problem: I print ONE copy of a multiple page document in Adobe Reader 9. I select even pages only (after which I would reinsert the pages and tell it to print odd pages only, to get the other side). The printer makes a sound indicating the job is finished, I remove my pages to collate them, and then the printer continues to print the job again without so much as a keystroke.
    Naturally, you find the printer in the devices on the control panel, click "see what's printing" and highlight the job and cancel it.
    Then somehow it turns off my print spooler. 
    I have tried everything suggested on other forums, like
    restart the laptop/restart the printer
    going to c\windows\system32\spool\printers and deleting whatever is hung up in there (usually a shockwave file).
    Going to Services\print spooler \properties and making sure the settings are set to automatic
    Uninstall\reinstall latest driver and software
    Switching from Adobe Reader 10 to Adobe Reader 9
    Use System Restore to try to reset the system to a previous state.
    Run Trend Micro to check for viruses and spyware--nothing shows up.
    I am positive the pdf doc is NOT the problem, because I can print it on my husband's laptop multiple times over with no problems.
    Does anyone have this problem as well? Has anyone found a genuine solution other than manually canceling print jobs in queue and constantly restarting the print spooler?
    Thanks in advance for any suggestions.
    --Holly

    Hi,
     I believe your printer is wirelessly connected to your computer, right?!
     What's the current printer software version installed in your laptop computer?! 
     to see: click start>control panel>uninstall a program under Programs then it will tell you the software version like HP Photosmart c309a v13 or v14.
    If the software version is v13, click here to download and install the current software.
    IF all things still fail, try to use the workaround provided by HP in this link. It says:
    Workaround
    Your HP printing product can operate sufficiently using an alternate print driver, although there might be some limitations. For instance, some buttons on the product control panel might not function, but the product prints normally from the computer. If the solutions in this document do not solve the issue, download and install an alternate print driver.
    Follow these steps to install the HP Deskjet 990C print driver.
      NOTE:  These steps install the new print driver using the same port that the product already uses. The product functions normally with multiple drivers on the same port.
    Find the port that the product already uses.
    Click the Windows icon ( ), and then click Control Panel . The Control Panel opens in a new window.
    Click Hardware and Sounds .
    Click Printers . The Printers folder opens.
    Right-click the product icon ( ), and then click Properties . The Propertieswindow opens.
    Click the Ports tab. A window opens with a list of ports. The port for the product has a checkmark or a highlight.
    Note the name of the port indicated for the product.
    Close the Properties window, and then continue with the next steps.
    Click Add a Printer in the menu bar at the top of the Printers window. The Windows Add Printer Wizard opens.
    Click Add a local printer .
    Select Use an existing Port .
    Click the drop-down menu next to Use an existing Port , and then select the port that you noted earlier in these steps.
    Click Next .
    In the Manufacturer pane, click HP .
    In the Printers pane, click HP Deskjet 990c , and then click Next . (IF YOU CANT FIND DESKJET 990C, JUST CLICK WINDOWS UPDATE WITHIN THIS WINDOW. THEN FIND DESKJET 990C and then click next)
    Type a name for the new printer in the Printer name box, or keep the default name.
    Select Set as the default printer , and then click Next . A window opens with a progress bar as the printer installs. Then a new window opens.
    Click Do not share this printer , and then click Next .
    If you want to print a test page, click the Print test page button.
    Click Finish to complete the driver installation.
    Try printing again, but select HP Deskjet 990c from the Print dialog box.
    If this solves the issue, follow these steps to use the HP Deskjet 990c print driver whenever you send print jobs to the product.
    In the program you are using, select the option to print. The Print dialog box opens.
    Click the Name drop-down menu, and then select HP Deskjet 990c .
    Change print settings as desired in the Paper size , Quality , and Paper type drop-down menus.
    Select the Print range and Copies options as desired.
    Click OK . The product prints the file.
    Kiko

  • How to get the PDF data which i have send to Spool

    Dear Freinds,
                   My requirement is to display the output which iam getting from a custom report(ZSALARY) in the form of  PDF . So now i wanted to display the ALV output  on to my desktop (as of now) in PDF format.
    i have done the below coding please correct me why iam not getting the same data which is coming out of my report in the PDF, iam passing the same internal table.
    IF NOT it_final[] IS INITIAL.       -
    >IT_FINAL is my main internal table in the report ZSALARY
          DATA : count TYPE syprcop,
             days TYPE sypexpi,
             params TYPE pri_params,
             valid TYPE c,
          pdf_table TYPE  rcl_bag_tline,
          spoolid TYPE rspoid,
          pdf_fsize TYPE  i.
            CALL FUNCTION 'GET_PRINT_PARAMETERS'
              EXPORTING
                destination    = 'LP01'
                copies         = count
                list_name      = 'ZSALARY'   -
    tHIS IS MY REPORT NAME
                list_text      = 'ZSSPOOL'
                immediately    = ' '
                release        = 'X'
                new_list_id    = 'X'
                expiration     = days
                line_size      = 90
                line_count     = 65
                layout         = 'X_PAPER'
                sap_cover_page = 'X'
                receiver       = 'SAP*'
                department     = 'System'
                no_dialog      = 'X'
              IMPORTING
                out_parameters = params
                valid          = valid.
            NEW-PAGE PRINT ON PARAMETERS params NO DIALOG.
            WRITE : 'hi this is the test for spool'.
            NEW-PAGE PRINT OFF.
            COMMIT WORK.
            WRITE : / 'The Spool no is ', sy-spono. "system variable for spool no
            spoolid = sy-spono   .       -
    At this point i can see the spool no.
            CALL FUNCTION 'CONVERT_ABAPSPOOLJOB_2_PDF'
              EXPORTING
                src_spoolid   = spoolid
                no_dialog     = 'X'
              IMPORTING
                pdf_bytecount = pdf_fsize
              TABLES
                pdf           = pdf_table
              EXCEPTIONS
                OTHERS        = 0.
            CHECK sy-subrc = 0.
            CALL FUNCTION 'GUI_DOWNLOAD'
              EXPORTING
                bin_filesize = pdf_fsize
                filename                = 'C:\Documents and Settings\Administrator\Desktop\test.pdf'
                filetype                = 'BIN'
              TABLES
                data_tab                = it_final
              EXCEPTIONS
                file_write_error        = 1
                no_batch                = 2
                gui_refuse_filetransfer = 3
                invalid_type            = 4
                OTHERS                  = 5.
          ENDIF.
    if i go and on my desktop it is saying the below error "ADOBE  READER COUDNT OPEN 'test.pdf'
    because it is either not supported  file type or because the file has been damaged.
    my aim is to get the data which is there in IT_final in the PDF .....please correct me the parameters which i have given wrong. my doubt is in GUI_download  fM  in the tables should i pass it_final or
    the pdf_table coming from'CONVERT_ABAPSPOOLJOB_2_PDF'...... i tried this option iam able to open and it is just giving message which i kept before this FM i.e  WRITE : 'hi this is the test for spool'.
    what i should to get my internal table data.
    Pls help.
    regards
    srinivas.

    Dear Karthik,
              Thank you for giving me the link there by iam able to get the ouput download int he pdf
    as below code , but now a small problem for me .......i have 10 fileds in the Report ouput ....but however in the pdf output i can see only 8 fields and the two fields got truncated . Could you please tell me what
    i have to change in my below code so that i can get all the values  
    IF NOT it_final[] IS INITIAL.
    data : it_tsp01 type standard table of tsp01,
           l_wa_tsp01 type tsp01.
            CALL FUNCTION 'GET_PRINT_PARAMETERS'
              EXPORTING
                destination    = 'LP01'
                copies         = count
                list_name      = 'ZHR_BON'
                list_text      = 'ZSSPOOL'
                immediately    = ' '
                release        = 'X'
                new_list_id    = 'X'
                expiration     = days
                line_size      = 90
                line_count     = 65
                layout         = 'X_PAPER'
                sap_cover_page = 'X'
                receiver       = 'SAP*'
                department     = 'System'
                no_dialog      = 'X'
              IMPORTING
                out_parameters = params
                valid          = valid.
    SUBMIT (sy-repid) TO SAP-SPOOL
                     SPOOL PARAMETERS mstr_print_parms
                     WITHOUT SPOOL DYNPRO
                    WITH pnppernr =  p0001-pernr
                     AND RETURN.
    CALL FUNCTION 'CONVERT_ABAPSPOOLJOB_2_PDF'
              EXPORTING
                src_spoolid   = spoolid
                 no_dialog     = 'X'
                 DST_DEVICE  = params-PDEST
               IMPORTING
               pdf_bytecount = pdf_fsize
              TABLES
                pdf           = pdf_table
              EXCEPTIONS
                OTHERS        = 0.
            CHECK sy-subrc = 0.
            CALL FUNCTION 'GUI_DOWNLOAD'
              EXPORTING
                bin_filesize            = pdf_fsize
                filename                = 'C:\Documents and Settings\Administrator\Desktop\test.pdf'
                filetype                = 'BIN'
              TABLES
                data_tab                = pdf_table    "it_final
              EXCEPTIONS
                file_write_error        = 1
                no_batch                = 2
                gui_refuse_filetransfer = 3
                invalid_type            = 4
                OTHERS                  = 5.
          ENDIF.
    Please tell me how i can get the all the fields which are there in my normal alv output ......
    Case 1) .i wanted all the 10 fields in PDF  to be displayed  without truncated , I have checked in Spool ........ i found all the fields are there .....but however when i check the downloaed PDF i can see some fields are getting truncated.
    Case 2) However  if on the ALV output if the user  hides 2 fields out of 10 fields then only 8 feilds which are appearing on the output  before sending the Spool should only be displayed in PDF as well -
    > for this scenario what i have to do.
    Thanks  Once again.
    regars
    srini.

  • Send print Request - Salary Statement

    Hi,
    Does anyone  have any information on this button. Where is it configured, how does it send print requests, can it be changes(send to different location) and what roles does the user require.
    Thanks
    Points to helpers

    Yep, definitely possible with EP7 and ECC6.
    You need a portal role that gives you access to the Content Administration menu.
    Easiest if your portal user ID is linked to an employee with payroll results in ECC (via Infotype 0105).
    Open the payslip iView in the Portal Content Studio and click the preview button.
    Ctrl + right click on the print button, set the Invisible flag to Yes.
    Apply the change, close the personalisation dialogue, save the iView and you're done.
    You'll notice after making any personalisation changes that some new entries appear in the iView properties, this is how global personalisation changes are stored.  The changes then get exported with the object to your other portal systems
    Cheers,
    John

  • Difference in printer spooling between 2 similar macs

    I'm trying to figure out why there is a difference in how my 2 Macs spool a print file.
    Sending the same large (276mb) Photoshop file to the same printer (Epson 11880) connected directly (no print server)on same hardwired network using Bonjour, using the same driver version (3.89) and same PPD version (1.0) using the exact same settings within the driver, the file gets handled differently within the spool application.
    Here are the two computers, their specs and what happens.
    *Comp 1*
    Power Mac G5 \ Dual 2.0 \ 6 GB Ram \ OS X 10.4.11
    File takes approx 30 mins to leave photoshop. Once printer spooler opens it "processors" entire file (approx 10mins), then "spools" to printer and the printer starts to print.
    *Comp 2*
    Power Mac G5 \ Dual 1.8 \ 4 GB Ram \ OS X 10.4.11
    File take approx 20 mins to leave photoshop. Once printer spooler opens it begins to print pretty much right away and I assume is "processing" while "spooling"
    So, the slower computer prints the file faster :/
    How can I adjust the spooling on the Dual 2.0
    Thanks for any help or suggestions.

    I have read so many conflicting answers to how necessary it is to "de-frag" these drives, what's your take on this ?
    It's reported that OSX defrags itself over time, but only on files over a certain size, (20 MB?).
    With as much free space as you have, it's not all that important to defrag. That being said, I'm a tinkering freak, and whenever I defrag, I see improved performance, but a lot of it has to do with my slower drives & Macs, SATA shows less improvement by defraging. If you get less than 20% free space Degragging will have more effect, but for a short time of course.
    We still haven't found your problem, so I'd get Applejack...
    http://www.versiontracker.com/dyn/moreinfo/macosx/19596
    After installing, reboot holding down CMD+s, then when the DOS like prompt shows, type in...
    applejack AUTO
    Then let it do all 5 of it's things.
    At least it'll eliminate some questions if it doesn't fix it.
    The 5 things it does are...
    Correct any Disk problems.
    Repair Permissions.
    Clear out Cache Files.
    Repair/check several plist files.
    Dump the VM files for a fresh start.
    Sometimes 2 or 3 restarts will be required for full benefit... my guess is files relying upon other files relying upon other files!

Maybe you are looking for

  • HP officejet Pro 8600 - Left margin on printer has shifted

    The left margin on my Officejet pro 8600 printer has shift approx 1". This is issue is not coming fro the computer it is in the printer. It happens when I copy or produce a test page from the printer control panel. Paper is set up properly in the pap

  • HP 4100mfp no display, no printing, fans only spin

    I have a customer that has a HP 4100mfp that acts like it is dead.  You flip on the power switch and the fan spins like it is going to power up, but the display never comes on.  Opening and closing doors don't make the machine cycle.  I've reseated t

  • Issue with Purchase requisition

    Hello SAP gurus, From ME53N I am not able to check the info-record. If I click on info-record from environment then system is throwing message u201CNo usable items exist for this selectionu201D. I checked source list and info-record is maintained, st

  • How to Pass Multiple Parameters To ReportReuest Method in Oracle  BI 11g

    Hi, Am integrate Oracle BI Publisher 11g via Web Services in Oracle Forms,For that am developing code in PublicReportServiceClient Class. This worked properly with out passing parameter to the report. so how to pass parameters to the report . If Repo

  • How to activate Workflow Agent listener Service - Oracle E-BIZ R12

    Environment DB : 11.1.0.7 Appl Rel. : R12.1.1 OS : RHEL 5.1 (x86_64) Following is the work around done to bring up WF Agent listener After Completion of Clone navigating to WORKFLOW system , Status of     Notication Mailers : Down           Agent Lis