Serial Number Replication from R/3 TO CRM

Hi Experts,
Currently the Equipments are replicating from R/3 to CRM. If we want to replicate only Serial Number as Individual Object , will their be any effect on the equipment already replicated to CRM or  what will be the effect of replicating Only Serial Number with out equipment.
We are working in 6.O version.
Can u please reply for this message  ASAP.........
regards,
Sarangamath
Edited by: Sarangamath on Dec 7, 2011 10:53 AM
Hi Experts,
Can you please reply on this issue - Its Urgent
Regards,
Sarangamath

Hi Kalyan;
  You can define different number ranges in R/3 and CRM.
As per my understatnding number ranges maintained in R/3 is  0000000001-ZZZZZZZZZZ which is already exist in CRM.
You can try following steps
1. Define new number range ( as an ext no range)in CRM as per your requirement (which is not used in CRM)
2. create new groupings then assign number range in to grouping.
3. Then go to R/3 and change the number ranges for BP as a internal number ranges
4.Goto T.Code PIDE there select R/3 to CRM. and enter the mapping details with new number ranges then start downloading.
If helps reward the points.
Regards
Jameem Khan.
TTL Mumbai

Similar Messages

  • I am trying to reinstall CS3 from a download I bought several years ago, and it is saying my serial number is invalid.  I am taking the serial number directly from the list of products on my Adobe account.  Please advise

    I am trying to reinstall CS3 from a download I bought several years ago, and it is saying my serial number is invalid.  I am taking the serial number directly from the list of products on my Adobe account.  Please advise

    Uninstall and try the Adobe Creative Suite Cleaner Tool before reinstalling - it helps resolve installation problems for CS3 thru CS6 and for Creative Cloud
    http://www.adobe.com/support/contact/cscleanertool.html

  • I purchased photoshop elements 8 on line in 2010. I recently switched to a new desktop computer. Photoshop asked for my serial number. I entered the correct serial number (obtained from Adobe). It says it is invalid. How do I get this corrected so I can u

    I purchased photoshop elements 8 on line in 2010. I recently switched to a new desktop computer. Photoshop asked for my serial number. I entered the correct serial number (obtained from Adobe). It says it is invalid. How do I get this corrected so I can use the product I purchased?

    Hi Rosera,
    This is bad and I am sorry to hear that you are running into these issues.
    Let me connect with you, so right now, the current state is that you have installed copy of PSE 8 in trial on your windows 7 machine, and when you are trying to enter the serial number from your PSE 8 Box, it is saying the serial number to be invalid?
    It might sound pretty obvious, but please make sure that you are entering the serial number correctly and of PSE 8(in case you bought a PEPE box)?
    Have you tried the steps mentioned below by Barbara?
    If possible, you can send me the serial number through PRIVATE MESSAGE and I can check it on my end that whether the serial number is indeed invalid or that the issue is with your machine?
    Regards,
    Ankush

  • Scheduled delta replication from R/3 to CRM

    Hello Experts,
    we are planing to download customer master data from R/3 to CRM. It will be a completely one sided connectivity and we dont want to upload anything from CRM to R/3. And we are planing for Initial load as well as Delta load from only R/3 to CRM. How can I set this?
    And the delta  down load, we want to perform automatically once in day at a specified time..so is it possible?if yes how?
    thanks in advance.
    regards,
    kalyan

    Hi Kalyan,
    If You are using the Administration Console to deassign a site from a subscription or a subscription from a site, or to delete a subscription.
    The type of the related publication is simple intelligent (sync), simple intelligent (msg) or simple bulk (msg). As a consequence, changes (insert, update, delete) of a BDoc instance are sent to a site only if the site has been assigned the corresponding subscription. The assignment or deassignment of such subscriptions will not trigger a synchronization of the site database.
    Example:
    Your site Back-End is of sitetype R/3. It has been assigned a subscription for a BDoc type. The type of the publication is simple bulk (msg). The creation of a business object (for example, business partner) with identifier 111111 ensures that this business object will be sent to site Back-End.
    After deassigning the subscription in the Administration Console all changes in business object 111111 will not be sent to the site Back-End. In addition, a newly created business object with identifier 222222 will also not be sent to site Back-End.
    As you reassign the subscription, the following inconsistencies occur:
    Business object 111111 has not been synchronized in the R/3 back-end.
    Business object 222222 is not available in the R/3 back-end.
    And for scheduling background job for delta replication from R/3 to CRM, i am not sure about it.
    Regards
    Nadh.

  • BP Replication from R/3 to CRM

    Hi Forum,
    I am facing an issue with BP Replication from R/3 to CRM.
    Although the same scenario and configuration works well on my dev and qual environment and the same has been trasported to Production, apart from that R3 dev and qual system are completely updated with Prod data as on date so there is no question of any mismatch at the data level and config level.
    The following are the error messages am receiving in SMW01 for BUPA_MAIN:
    1. Business partner with GUID 36F36B473D31C04985CC8AEB314C6BE3 does not exist
    2. Validation error occurred: Module CRM_BUPA_MAIN_VAL, BDoc type BUPA_MAIN
    Now none of my BP are flowing to CRM because of this issue.
    Appreciate any pointers for the resolution.
    Regards,
    Amit

    Hi Vikash,
    The RFCu2019s have been checked for authorisation test, remote logon n local logon. The RFC user is a dialog user and is working well for all logon. I have also checked both the systems they have the logical names as described by you (source & destination both).
    Another thing that validated my point regarding the connection setting is that the materials are flowing fine between the system and even the changes in these materials are replicating properly hence the delta for material is also fine.
    The Inbound and Outbound queues have been deleted from both r3 and crm and the only job running again at the moment is customer_main.
    Regarding you concern for the queue R3AI* it has not been generated even once whenever I have started the initial load. Right from the starting I am monitoring R3AD* in all the outbound and Inbound queues of both the systems.
    The sysfail message is coming for R3AD queue hence I think it is of no use to us. Still if I follow the error message it points towards SMW01 and there the error message is the same as described in the 1st message.
    I have just noticed 2 BP that have come in CRM as STP but its been hours after that no BP is flowing in.
    Now I am eagerly looking out for the final findings that we are going to get from the system when the issue is resolved.
    Thanks again and appreciate the efforts taken from your end.
    Regards,
    Amit

  • Custom fields mapping issue of sales order replication from R/3 to CRM

    Hello Experts,
    I have to replicate sales orders from R/3 to CRM system (Initial and Delta)
    The issue is I have custome fields in R/3 which are maintained in custom table(Z table) in R/3.
    We added those custom fields in CRM customer_i table to synchronise with R/3 data.
    To MAP R/3 custom fields to CRM custom fields, i have the following customization.
    1. Added the custom function module in the event CRMO_200 and moved all the custom fields into interal table  IT_OTHER_INFO.
    2. The intrnal table IT_OTHER_INFO with data is passed into CRM standard function modules.
    3. But in CRM the BADI 'CRM_DATAEXCHG_BADI' implementation does not have the input parameter of internal table TI_OTHER_INFO.
    All my custom data is in internal table TI_OTHER_INFO.
    Please suggest where can i map this data to CRM enhanced fields.
    Regards,
    Umashankar.

    Hello Vanessa,
    Thank you so much for your reply.
    I went through the Note (1053817). It is good. I understand that the custom fields should enhance in the BAPE_VBAP in R/3.
    My Scenario:
    Goal: Orders replication from R/3 to CRM along with Custom fields.
    In R/3, all the custom fields are maintained in Z table (Not VBAK or VBAP).
    All these custom fields are belongs to Item level.
    In CRM, The custom fields are maintained in CRMD_CUSTOMER_I table though AET.
    I need to MAP these custom fields to CRM while order replication from R/3 to CRM.
    Regards,
    Umashankar.

  • Hi, my ipad got stolen and i was wondering if there is anyway of finding out the serial number remotely from another apple device?

    Hi, my ipad got stolen and i was wondering if there is anyway of finding out the serial number remotely from another apple device?

    If it iwas registered to your account then you should be able to get it from your support profile : https://supportprofile.apple.com/
    If not then do you have a backup of the iPad on your computer's iTunes ? If you do then in iTunes go into Edit > Preferences (iTunes > Preferences if using a Mac) and on the Devices tab on that hover your mouse pointer over the iPad's backup : http://support.apple.com/kb/HT4061

  • How to pass serial number read from a PCB.

    Hi,
    I have a question:
    How do I pass serial number read from a PCB so it will be embedded in Test Report file name for that test sequence. I am running Sequence in “New Execution" - Single Pass.
    My test report file after I run test does not have serial number: “TEST_Rev6_Report[NO_UUT_SERIAL_NUM0][2 32 24 PM][4 26 2013].xml” but my Report Header has serial number present.
    Thank you,
    Henry

    The attached screenshot shows how to set your report options, make sure you have the <TestSocket> and <UUTStatus> macros included in the Report File Path otherwise the serial will not be filled in the filename (Generate path is called a second time from the Single Pass -- Test Socket Entry Point sequence).
    I used the ParallelModel.seq to test it.
    The attached sequence file shows how to set the serial number.
    Search for "Specifying Report File Paths by Expression" in the help for more macros.
    Attachments:
    Sequence File 2.seq ‏5 KB
    Screenshot.png ‏57 KB

  • How do I find the time capsule serial number remotely from my mac?

    How do I find the time capsule serial number remotely from my mac?

    Hi All,
    I found it in my Support profile.  https://supportprofile.apple.com.
    Thanks.
    Richie

  • Serial number recovery from a damaged drive will not activate

    purchased replacement disks aor mac book Illustrator CS3 for a new hard drive. had the serial numver extractred from the old hard drive, but I get a red X.
    Suupport says I need to go to the forum as,it is not a valid  serial number.

    DA,
    Tell Support that forum says it is a matter for Support.
    You may try here (tick I Still Need Help, you may start a chat straight away if you are lucky):
    http://helpx.adobe.com/contact.html?product=illustrator&topic=downloading-installing-and-s etting-up
    If you get nowhere with them, please report back, and i can ask some staff to ask them to do what they are supposed to do.

  • Create serial number - asset from goods receipt

    Hi,
    We configured the sync functionality between PM and AA, so when we create a serial number via transaction IQ01, the fixed asset master data is created automatically.  We also configured the serial number profile in the material master.  When we create a goods receipt (MIGO) the serial number data screen comes into place.  We save the GR document, and when we check the serial number data in PM this info is correct, but the synchronization between fixed asset didn't work it means, no asset master data is created.  Is there some missing configuration?  Even the tcode IQ01 works fine, why in this operation (MIGO) the configuration doesn't work ?
    Any help on this topic we'll be very appreciated.
    Lee

    Hi,
    in customizing transaction OIS2 I'm using the serial number profile 0010 (Stock check) and in the serializing procedure Goods Receipt and Issue Doc (MMSL), the serialization usage is 03 and the equipment requirement is 02 (always with equipment).   When use MIGO for goods receipt I noticed that after the serial number creation (via tcode IQ03) some serial number mandatory fields have no value, like Company Code (BUKRS) and Cost Center (KOSTL), and other mandatory fields for the master records.  If I modify the serial number (tcode IQ02) and complete the mandatory fields, the synchronization work fine since the asset master record is created.   I'm suspecting that some of these fields (like company code) are necessary for the asset creation.  I checked the whole PM/AA/MM configuration for these fields to in some way, assign them the corresponding value taken from the goods receipt or material and give it to the serial number record for creation.  If you know something else please let me know.
    Thanks for your response.
    J.R.Lee

  • Create serial number - asset from goods receipt (MIGO)

    Hi,
    We configured the sync functionality between PM and AA, so when we create a serial number via transaction IQ01, the fixed asset master data is created automatically.  We also configured the serial number profile in the material master.  When we create a goods receipt (MIGO) the serial number data screen comes into place.  We save the GR document, and when we check the serial number data in PM this info is correct, but the synchronization between fixed asset didn't work it means, no asset master data is created.  Is there some missing configuration?  Even the tcode IQ01 works fine, why in this operation (MIGO) the configuration doesn't work ?
    Any help on this topic we'll be very appreciated.
    Lee

    Hi,
    in customizing transaction OIS2 I'm using the serial number profile 0010 (Stock check) and in the serializing procedure Goods Receipt and Issue Doc (MMSL), the serialization usage is 03 and the equipment requirement is 02 (always with equipment).   When use MIGO for goods receipt I noticed that after the serial number creation (via tcode IQ03) some serial number mandatory fields have no value, like Company Code (BUKRS) and Cost Center (KOSTL), and other mandatory fields for the master records.  If I modify the serial number (tcode IQ02) and complete the mandatory fields, the synchronization work fine since the asset master record is created.   I'm suspecting that some of these fields (like company code) are necessary for the asset creation.  I checked the whole PM/AA/MM configuration for these fields to in some way, assign them the corresponding value taken from the goods receipt or material and give it to the serial number record for creation.  If you know something else please let me know.
    Thanks for your response.
    J.R.Lee

  • Serial Number lost from PhotoshopCS6

    Dear sir, madam,
    Last week I have a crash on my computer. From that moment my offical Photoshop CS6 was changed in a trail version. I can not find my serial number. In my Adobe account I only can find the serial number of my previous Photoshop CS 4  but this number is not correct.
    In any way I can find the good serial number for Photoshop CS6.
    Hope that you can help me.
    With Regards,
    George van de Winkel
    Transmedia-Design
    Haarlem
    [email protected]

    Nederlands support is 0202013331 but it is probably closed now.
    Try the chat: https://sales.liveperson.net/hc/57472748/?cmd=file&file=visitorWantsToChat&site=57472748&v isitor=11242077484984&msessionkey=7191402948965568935&siteContainer=STANDALONE&LEAppKey=f9 07f2d9acd64b7f8c00b83bed3c2822&SV!chat-button-name=chat-service-acrobat-universal-english- contact-1&SV!chat-button-room=chat-service-acrobat-universal-english-contact-1&referrer=(b utton%20dynamic-button:chat-service-acrobat-universal-english-contact-1(Contact%20opnemen% 20met%20de%20klantenservice))%20http%3A//helpx.adobe.com/nl/contact.html%3Fproduct%3Dacrob at%26topic%3Ddownloading-installing-and-setting-up&SESSIONVAR!skill=service-acrobat-univer sal-english&visitor=11242077484984&msessionkey=7191402948965568935

  • Serial Number - upgrade from 5 to 6 - 5 serial number for version 5 missing / lost

    Hi,  I bought Lightroom 5 a year or so ago from a shop, it was a download card with a serial number on it.  I have just bought the upgrade to version 6, but have been asked for the old version 5 serial number. The card is now missing and so I wondered where I can find the version 5 serial number?  
    Thanks for any help!

    Excellent thank for your help.  I fixed it another way eventually.  The serial number in Lightroom has xxxx for the last 4 digits.  Luckily I was upgrading to 6 on the same computer and so I was able to register Lightroom 5, which gave me the full serial number when I logged into my account.
    Thanks for taking the time to reply though, I appreciate it.

  • Serial number disappears from the system profiler... How to get it back?

    Hi there,
    We have come across a known behaviour where the serial number of the computer disappears from the system profiler and 'about this mac' menu, whwnever the logic board is replaced. Any ideas how to get this information back on the computer(Seems all the macs are affected)
    Is it possible to flash the firmware to copy the contents? Heard someone trying to flash BIOS? will this work or will it damage the firmware? Please HELP!!!

    You might want to take a look at this Developer Tech Note:
    http://developer.apple.com/technotes/tn/tn1103.html
    Specifically, this quote:
    "Caveats for using the serial number
    It is possible for a system to lose its serial number so that it will no longer appear either in System Profiler or the I/O Registry. Repairing a system by swapping hardware components is one reason this can happen. Apple does not document the specific details of how a machine can lose its serial number. Once the serial number has been lost there is no means to restore it to the machine."
    It sounds like there may not be an easy (or documented) way to put the serial number back.
    Steve

Maybe you are looking for