Server0 node restarts automatically after 10 minutes...

Hello Portal ppl..
I have encountered a troublesome porblem at My portal server.
Server0 node restarts automatically after 10 minutes...showing yellow status..
Following is developer trace of server0 node:
[Thr 373752] Tue Dec 30 12:52:01 2008
[Thr 373752] JLaunchISetClusterId: set cluster id 12403050
[Thr 373752] JLaunchISetState: change state from [Initial (0)] to [Waiting for start (1)]
[Thr 373752] JLaunchISetState: change state from [Waiting for start (1)] to [Starting (2)]
[Thr 377684] Tue Dec 30 12:53:00 2008
[Thr 377684] JHVM_RegisterNatives: registering methods in com.sap.security.core.server.vsi.service.jni.VirusScanInterface
Following is developer trace of jcontrol.exe node:
[Thr 379212] Tue Dec 30 12:51:37 2008
[Thr 379212] JControlICheckProcessList: process SDM started (PID:379984)
[Thr 379212] Tue Dec 30 12:51:57 2008
[Thr 379212] JControlICheckProcessList: process server0 (pid:380868) died (RUN-FLAG)
[Thr 379212] JControlIResetProcess: reset process server0
[Thr 379212] JControlICheckProcessList: running flight recorder:
     C:\j2sdk1.4.2_12\bin\java -classpath ../j2ee/cluster/bootstrap/sap.comtcbloffline_launcherimpl.jar com.sap.engine.offline.OfflineToolStart com.sap.engine.flightrecorder.core.Collector ../j2ee/cluster/bootstrap -node ID12403050 1230620106 -bz D:\usr\sap\E70\SYS\global
JControlStartJLaunch: program = D:\usr\sap\E70\JC01\exe\jlaunch.exe
-> arg[00] = D:\usr\sap\E70\JC01\exe\jlaunch.exe
-> arg[01] = pf=D:\usr\sap\E70\SYS\profile\E70_JC01_infpu05445
-> arg[02] = -DSAPINFO=E70_01_server
-> arg[03] = -nodeId=1
-> arg[04] = -file=D:\usr\sap\E70\JC01\j2ee\cluster\instance.properties
-> arg[05] = -syncSem=JSTARTUP_WAIT_ON_359972
-> arg[06] = -nodeName=ID12403050
-> arg[07] = -jvmOutFile=D:\usr\sap\E70\JC01\work\jvm_server0.out
-> arg[08] = -jvmOutMode=append
-> arg[09] = -stdOutFile=D:\usr\sap\E70\JC01\work\std_server0.out
-> arg[10] = -stdOutMode=append
-> arg[11] = -traceMode=append
-> arg[12] = -locOutFile=D:\usr\sap\E70\JC01\work\dev_server0
-> arg[13] = -mode=JCONTROL
-> arg[14] = -debugMode=yes
-> arg[15] = pf=D:\usr\sap\E70\SYS\profile\E70_JC01_infpu05445
-> lib path = PATH=C:\j2sdk1.4.2_12\jre\bin\server;C:\j2sdk1.4.2_12\jre\bin;D:\oracle\E70\102\bin;C:\Program Files\CA\SC\CAWIN\;C:\WINDOWS\system32;C:\WINDOWS;C:\WINDOWS\System32\Wbem;C:\PROGRA~1\CA\SC\CAM\bin;C:\Program Files\CA\DSM\bin;D:\usr\sap\E70\SYS\exe\uc\NTI386
-> exe path = PATH=C:\j2sdk1.4.2_12\bin;D:\usr\sap\E70\JC01\j2ee\os_libs;D:\oracle\E70\102\bin;C:\Program Files\CA\SC\CAWIN\;C:\WINDOWS\system32;C:\WINDOWS;C:\WINDOWS\System32\Wbem;C:\PROGRA~1\CA\SC\CAM\bin;C:\Program Files\CA\DSM\bin;D:\usr\sap\E70\SYS\exe\uc\NTI386
[Thr 379212] JControlICheckProcessList: process server0 started (PID:358680)
Please Help.....

Hi,
To see the log files,
You can create an iView based on the below par file
com.sap.portal.runtime.admin.logviewer.
Use the component default in the PAR File.
Preview this iview to see the console for logs.
And regarding your error,Please check if the there is free space in the Hard Drive of USR folder
Also recheck the JVM settings according to Note 723909 - Java VM settings for J2EE 6.40/7.0.
Based on the 32 bit or 64 bit OS,the parameter values differ
Following are the Parameters for 64 bit OS.
-XX:MaxPermSize=512M
-XX:PermSize=512M
-Xmx2048M
-Xms2048M
-XX:NewSize=320M
-XX:MaxNewSize=320M
Hope it helps.
Cheers,
Santhosh

Similar Messages

  • SSRS 2008 R2 Services not restarting automatically after reboot

    SSRS 2008 R2  Reporting instance not restarting automatically after patches install.  Is there a way to resolve the issue
    Windows 2008 R2 Server
    16 GB RAM

    Hi,
    Follow this article to resolve the issue:
    Reporting Services service doesn't start after the installation of MS12-070 security patch
    http://blogs.msdn.com/b/mariae/archive/2012/11/12/reporting-services-service-doesn-t-start-after-the-installation-of-ms12-070-security-patch.aspx
    Workaround 1:
    Modify the registry to increase the default time-out value for the service control manager. To increase this value to 60 seconds, follow these steps:
    1. Click Start, click Run, type regedit,and then click OK.
    2. Locate and then click the following registry subkey:
    HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control.
    3.  In the right pane, locate the ServicesPipeTimeout entry.
    Note If the ServicesPipeTimeout entry does not exist, you must créate it. To do this, follow these steps:
    a.On the Edit menu, point to New, and then click DWORD Value.
    b.Type ServicesPipeTimeout, and then press ENTER.
    c.Right-click ServicesPipeTimeout, and then click Modify.
    d.Click Decimal, type 60000, and then click OK.
    This value represents the time in milliseconds before
    Restart the computer for the changes to take effect. Check that SSRS services can be started now.
    You cannot start SQL Server Reporting Services after you apply the update that is discussed in KB 2677070
    http://support.microsoft.com/kb/2745448/en-us
    Thanks.
    Tracy Cai
    TechNet Community Support

  • Motorola DROID X Restarts Automatically After I  Shutdown

    My Motorola DROID X Now Restarts Automatically After I  Shut It Down (50% of the time?). It worked great at first.
    I have used soft & hard resets & this problem persists.
    Is there a software fix for this?

    Thank you Vanessa for acknowledging the problem and for Verizon working on a solution!
    Mike
    VanessaC_VZW wrote:
    Good morning and thanks for all the feedback!
    This issue has been lifted up, as there have been other reports of the Droid X powering up on its own after being turned off.  Our product team is working to resolve this; however, there is no date on a software resolution yet.  Once a software update becomes available, it will be pushed through your phone. 
    We appreciate your patience.
    Thank you,

  • My iphone 5 crashes (restarts) automatically after updating to ios 7.1 anyboday facing same issues ? Need help !!!!

    my iphone 5 crashes (restarts) automatically after updating to ios 7.1 anyboday facing same issues ? Need help !!!!

    I am having the same issues--just got off phone with customer service rep--was told that my phone is in recoveyr mode and that I would have to restore it, however, the only things that would be restored would be from my last backup which was in November 2013!  I was also told that apple users should not update as soon as the update is available (so why are they sending it to us if they're not sure that there will be any problems!!!).  I can't restore now since I am in work--will do it when I go home tonight.  In the meantime, I am without a working iphone for the day!  This is horrible--I see I'm not the only one who has experienced this!

  • How to get Mavericks server that is connected to a UPS to restart automatically after a power outage.

    This is driving me crazy. Is there anyone running Mavericks as a mission critical server on Backup Power Supplies that has a way to get the servers to restart automatically after a power outage. The UPS vendors all have software for Windows, but not Macs, and the setting in System Preferences, doesn't work with the UPS's Iv'e tried (2 different APC models (Smart and Back-UPs), one Triplite (Smart) and one CyberPower, (all claiming to be Mac compatible))

    APC do apparently still do a command-line daemon (PowerChute Network Shutdown) which monitors over the network the UPS and will cleanly shutdown the Mac. For lower-end UPS devices these are typically connected via a USB cable and the built-in Apple System Preferences let you control the options - if it is a model supported. There is however a big limitation of using a USB connection which is that you can only connect a single computer to a UPS via USB and of course most companies have multiple servers.
    It maybe that what is happening even if you use APC's software is the following -
    Power failure detected by UPS
    Signal sent to Mac
    Computer does a clean shutdown
    Power restored
    UPS has no way to tell Mac because it is shutdown and Mac does not support 'Wake on LAN' if fully shutdown
    The Mac does have an option to 'Startup automatically after a power failure'. However this might only take place if the Mac is not cleanly shutdown, it could be that if the Mac is cleanly shutdown it does not count this as a power failure. If this is correct then there is nothing that can be done as users to resolve this, the only way it could be resolved would be if Apple provided a way for a tool like APCs software to both do a clean shutdown and set a flag as this being due to a power failure so that when the Mac does detect the power being restored it triggers the Mac in to booting.
    In the dim and distant past when Macs used ADB to connect keyboards and mice the ADB interface did support an external power-on signal. This does not exist for USB.
    Personally I have regarded the APC software (PowerChute Network Shutdown 3.0.1) to be so badly supported and so old as to be too risky to use. It lists 10.7 and 10.8 but not 10.9 and uses Java 1.6 which itself is unsupported. There is a third-party tool you might want to look at called NUT (Network Ups Tools) see http://www.networkupstools.org
    NUT is free and lets you do clever things like -
    Connect a single computer via serial or USB to the UPS
    Act as a 'server' over the network to other computers sharing the UPS
    When power failure is detected the NUT 'server' sends a signal to the NUT 'clients' so all of them know that there is a power failure and can do their own clean shutdowns
    This gets round only being able to connect a single computer via USB.

  • Phone hangs and restarts automatically after sim c...

    phone hangs and restarts automatically after sim change in my lumia 520.
    why is it happening? Can anyone help?

    Teh SIM you put in was that anew or a used SIM? if not new get it replaced for one.
    Click on the blue Star Icon below if my advice has helped you or press the 'Accept As Solution' link if I solved your problem..

  • Nokia N72 it restarts automatically every minute.

    Hi, Newly bought Nokia N72 phone it restarts automatically every minute. But when i put the bluetooth on the phone remains stable and it does not reboot. Once the bluetooth is switched off again the phone starts rebooting automatically every minute. Please let me know if there is any solution for that.

    Update your Firmware with latest one.Either take it to NOKIA CARE or do it from the wesite of NOKIA but do take back up of all your data.

  • I am having iphone 5. my phoen restarts automatically after i switch it off while not on charging. but when it is charging it works normally. battery also discharge in 1 hour.

    i am having iphone 5. my phoen restarts automatically after i switch it off while not on charging. but when it is charging it works normally. battery also discharge in 1 hour.

    basically i bought this phone from canada & using it in india. i tried to contact apple support in india, they told that the warranty is valid in the country where you purchsed this phone. very ammazing. Apple is a very big brand name & they are not serving their costumers in other country. any suggestions?

  • Nokia 5800 restarting automatically after firmware...

    recently i had updated my firmware through phone itself,after that its getting restarted automatically once or twice in a day. Since the problem persists i reinstalled the s/w through system also.but the problem is still there ,can anybody help me

    hi, I had same problem when I upgraded my damned 5800 to version 50. At first after the upgrade, it was reseting once in 2-3 minutes. I decided to format sd card and after that reseting times reduced to twice a day espicially after sending sms. Changing the microsdhc card with an old one with 1 GB capacity, compeletely solved the problem. Yesterday I bought a brand new micro sdhc : Verbatim 8GB class 4; but its the problem : its not working well. its slow and while connecting to pc it causes some fault. but the restarting problem is solved. Please recommand me a good microsdhc card.

  • Notify when managed server restarts automatically after a crash.

    I am trying to see if there is some way I can be notified (by email) when a managed server a cluster restarts automatically. I am running Weblogic 9.2 on Solaris Sparc 5.10.
    I can certainly compare the PIDs of the last and the new JVM but am looking for a slick way to do it especially at the Node Manager level.
    Thanks.

    Hi,
    *The server was started in warning mode and the JTA was declared unhealthy. I saw 2 transaction alive for more than 2000 seconds which is uncommon.
    *The resource adaptor was started properly.
    *We are using file store. But will it make a difference?
    Thanks!

  • Satellite Pro L40 PSL4BE restarts automatically after shutdown

    Hi,
    I have an issue where my laptop starts up automatically after seemingly going into hibernation and shutting down by closing the lid. (I have it configured so it goes into hibernation when i close the lid.)
    The strange thing is that this only happens when it's hooked up to the power supply. If i close the lid when it's on battery power it goes into hibernation and remains shut down as it should.
    This all started when i changed my power scheme from "Balanced" to "Performance". Setting it back to "Balanced" did not help, nor did setting it to the lowest setting. Also, it used to come back out of hibernation automatically after i opened the lid, this no longer happens either.
    I am unsure of whether this is a software or hardware issue.
    Over the weekend i've reinstalled the laptop using the supplied recovery discs and applied all updates and patches for Vista but the problem remains, so now i am leaning more towards it being a hardware issue even though i have no idea what kind of hardware malfunction could be causing this.
    Does anyone have an idea of what could be causing this behavior?

    Hello,
    Thanks for the replies. I'm afraid i haven't found any solution yet.
    Over the weekend I installed Ubuntu on this laptop and tried to hibernate but it demonstrated the exact same behaviour as under Vista. it shuts down and like 10 seconds after it boots back up. this leads me to believe that the problem is hardware related in some way. it would surprise me that both vista and a linux distro would have the exact same issues. So now i'm back on the Vista i restored using the restore discs.
    I haven't tried installing a windows xp yet though i suspect i'll have the same issues.
    @Sasha
    The thing is that the problem isn't in windows hibernating or not shutting down when the lid closes. It does that part just fine. What it shouldn't do however is restarting by itself whithout my intervention several seconds after it shut down. no matter the setting, that can't be normal behaviour.
    @borge & Jonnie
    Have any of you already had contact with the toshiba helpdesk on this issue? if so, what did they say? i haven't had the time to call them yet.
    I'll update as i find out more.

  • Some Systems Restarted Automatically after Updates Deployment with Restart Suppressed

    I've searched the forum and multiple blogs - but, I'm still confused about what is causing some of our workstations to restart after applying a software updates deployment.
    I deployed the Dec 2013 Patch Tuesday updates to a collection of workstations. The deployment was set to:
    Not allow restarts outside of a maintenance window (box is unchecked)
    Suppress restarts on workstations (box is checked).
    There is no maintenance window defined for any of our workstations
    On all the workstations, the HKEY_LOCAL_MACHINE\Software\...\WindowsUpdate\  values are:
    WUServer: http address of our SCCM SUP server
    WUStatusServer: http address of our SCCM SUP server
    Also, the key in HKEY_LOCAL_MACHINE\...\WindowsUPDATE\AU is:
    UseWUServer: 1  (which I understand disables the use of the automatic Windows update service)
    Some set of workstations automatically restarted shortly after 3:00 am the next morning. Clearly that's the Windows Update Agent jumping in a restarting the systems. However, I don't understand why it would do that. I really don't understand why it would
    have occurred on only some of the workstations while others are still waiting for users to manually restart 36 hours later.
    All of the workstations are in the same active directory OU - so the same set of GPOs applies to all.
    Note: none of the registry keys were set directly in any GPOs - I assume the values were set by the SCCM client.
    Any assistance would be appreciated.
    Larry

    depending on the OS version, this could be relevant:
    http://blogs.technet.com/b/wsus/archive/2013/06/11/wsus-blog-managing-updates-with-deadlines-in-an-era-of-automatic-maintenance.aspx
    http://blogs.technet.com/b/wsus/archive/2013/10/08/enabling-a-more-predictable-windows-update-experience-for-windows-8-and-windows-server-2012-kb-2885694.aspx
    Don
    (Please take a moment to "Vote as Helpful" and/or "Mark as Answer", where applicable.
    This helps the community, keeps the forums tidy, and recognises useful contributions. Thanks!)

  • Xperia L is turned off and restarting automatically after the 15.3.A.0.26 update.

    After the new update to Build Number : 15.3.A.0.26 My Zperia L is getting switched off and restarting automatically while using the google chrome for internet surfing.I tried software update using sony pc compain for more than 8 times. Tried out all the facilities provided by sony,but it didn't come to use.My phone was working properly before this update.now i cant even use it,i dont know when its going to restart,when its going to freeze.tried out all the possible helps from sony.please find a solution.And don't provide any lame updates like this.sony mobiles are getting worse after the software updates.Please provide a stable firmware.Hoping for a favourable reply.

    Do you experience the same problem in safe mode? 
    http://talk.sonymobile.com/t5/FAQ/How-to-boot-your-phone-into-safe-mode/m-p/348008#U348008
    If you do, please reinstall the phone software using Update Service: 
    http://www.sonymobile.com/global-en/tools/update-service/
    You could also try to remove SIM and SD card from the phone and try the phone without to see if you experience any problems. 

  • IPad restarting Automatically after IOS 8 Upgrade

    I purchased an IPad Mini with retina display in Aug 2014, upgraded to IOS8 on 19-sep 2014, since then the IPad has restarted automatically when I was browsing through the App store specifically.
    What is the reason for this freak occurrence.
    Rgrds
    Sukumar

    (A) Try reset iPad
    Hold the Sleep/Wake and Home button down together until you see the Apple Logo.
    Note: Data will not be affected.
    (B) Close all apps in the multi-task window
    1.Double-click the Home button.
    2. Swipe the app's preview up to close it.
    3. Preview will fly off the screen.

  • OC4J instance restarts automatically after 10 seconds.

    Hello Friends,IT System Administrators,
    I am using Oracle Application Server 10.1.2 on IBM AIX 5.3 Platform. Since many days, my "OC4J" service restarts automatically in 10 seconds. By counting error logs in /ORACLE_HOME/opmn/logs/ipm.log,i have found below errors.
    10/01/01 15:05:20 [4] Process Crashed: OC4J~WEBVAT~default_island~1 (864289932:626744) - Restarting
    10/01/01 15:05:22 [4] Starting Process: OC4J~WEBVAT~default_island~1 (864289933:0)
    10/01/01 15:05:29 [4] Process Alive: OC4J~WEBVAT~default_island~1 (864289933:729570)
    10/01/01 15:28:29 [3] [libopmnoc4j] Could not connect to socket while pinging an OC4J process
    10/01/01 15:28:29 [4] [libopmnoc4j] Process Ping Failed: OC4J~WEBVAT~default_island~1 (864289933:729570)
    10/01/01 15:28:29 [4] Job 0 9969720 result:
    ias_admin.gjvatwb1~OC4J~WEBVAT~default_island~864289933:729570
    Status: Alive
    Operation: internal (Connection refused)
    ErrFile: /oracle/ora10gas/opmn/logs/OC4J~WEBPROBE~default_island~1
    Kindly help me out to sort out this issue.
    Nishith Vyas

    Hi,
    To see the log files,
    You can create an iView based on the below par file
    com.sap.portal.runtime.admin.logviewer.
    Use the component default in the PAR File.
    Preview this iview to see the console for logs.
    And regarding your error,Please check if the there is free space in the Hard Drive of USR folder
    Also recheck the JVM settings according to Note 723909 - Java VM settings for J2EE 6.40/7.0.
    Based on the 32 bit or 64 bit OS,the parameter values differ
    Following are the Parameters for 64 bit OS.
    -XX:MaxPermSize=512M
    -XX:PermSize=512M
    -Xmx2048M
    -Xms2048M
    -XX:NewSize=320M
    -XX:MaxNewSize=320M
    Hope it helps.
    Cheers,
    Santhosh

Maybe you are looking for

  • Page appears different in browser

    I am responsible for updating my company's website in dreamweaver and am having problems with the layout.  The main page is at this link: http://teom-bfms.faa.gov/.  If you are unable to see it, let me know and I'll send you a screenshot.  There are

  • HU_PACKING_AND_UNPACKING

    Hi all, I would like to use the function called HU_PACKING_AND_UNPACKING, to pack one or more Handling Units of an outbound delivery into another Handling Unit. Normally this can be done through transaction vl02n and than go to packing (of HU's). I n

  • Report Output in text giving junk characters

    Hi All I have created custom report in rdf file format. When running the report set output as PDF means its come good. Incase i will change report output as text means its shows lot of junk characters in output time . How can i will solve the issue S

  • IBase component number changed

    Good day! After applying SP18 on Solution Manager I have encountered a problem: iBase component number for productive ERP-system has changed three times. (first it was 50, then 250, then 268, now 691). Right now the process for keeping up to date inf

  • Accesing controls (references) from several VI's

    Ok I have this small problem: I have a large program and have put serveral "advanced settings" in a different VI. Result is that the values entered here need to be passed to controls in different other VI's The way I use this now is using 1 element q