Setting a time out limit for OBIEE Queries

Hi Experts,
I am using OBIEE 11g. I have a scenario where I have to cancell a query if the query runs for more than 15 mins to fetch the data. The requirement is if the query takes longer than 15 mins the query to the database should be cancelled and in the OBIEE answers it should show the query cancelled message. Even if we are not able to show the exact message in answers is fine. But the front end and backend query must be cancelled after running for 15 mins.
Any help on this would be highly appreciated. Thanks in Advance.
Satyabrat

Hi,
Please try the following:
Add the below code in instanceconfig.xml
To set time to expire for Idle Oracle BI Presentation services Client connections.
<ConnectionExpireMinutes>Number of Minutes</ConnectionExpireMinutes>
Setting the Time to Expire for Oracle BI Presentation Services Client Sessions
<ClientSessionExpireMinutes>Number of Minutes</ClientSessionExpireMinutes>
And also try in RPD
Go to Manage-->Identity-->Application Roles
Select the ROLE and click on the permissions tab.
In the next wizard go to the “Query limits” tab.
Against the database row set the following values
Max Time Minutes=20
Status Max Time=Enable
For Custom messages for the error message:
Find error webmessage template and rewrite it in customMessages. For example:
<WebMessage name="kmsgCatalogAccessDenied" exception="true">
<TEXT>Отказ в доступе на <sawm:param insert="2"/> пользователю <sawm:param insert="3"/> по пути <sawm:param insert="1"/>.</TEXT>
</WebMessage>
Found this in catalogmessages.xml. Then I created file custommessages.xml in msgdb\customMessages:
<?xml version="1.0" encoding="utf-8" ?>
<WebMessageTables xmlns:sawm="com.siebel.analytics.web/message/v1">
<WebMessageTable system="CustomMessages">
<WebMessage name="kmsgCatalogAccessDenied" exception="true"><TEXT>Some other error message</TEXT></WebMessage>
</WebMessageTable>
</WebMessageTables>
It's possible not to show error message code.
There are a lot of perfect examples in the documentation.
Also Please refer the below link:
http://sranka.wordpress.com/2008/05/23/style-sheet-changes-custom-look-and-feel-in-obiee/
This should resolve your problem
Regards
MuRam

Similar Messages

  • Time-out limit of the 8451-I2C interface for hold-master condition

    I am working with Windows XP, Labview 8 and the USB-8451 I2C to USB interface-box.
    We intend to incorporate the USB-8451 into our product evaluation kits for a new sensor product.
    This evaluation kits should be used by our customers when they start working with our sensor products.
    The I2C-device is a digital sensor which generates a hold-master condition with difference length, depending on the sensor configuration.
    The hold-master is produced by the sensor after full transmassion of  start-bit, address, read-bit and ACK.
    After the hold master is suspended three bytes can be read by the master.
    If the hold-master is kept by the sensor for 25 ms or less I have no problems. When keeping it significantly longer the interface seems not to work properly anymore. I don't get a LabView Error-Message but the PC (Windows?) creates a 'ding-dong' sound very similar to disconnecting and connection a USB device. (the 8451???). My LabView-Program does not show sensor data after this.
    I can imagine that the hold-master is somehow too long for one element in the system.
    Is there any time-out period for hold-master defined for the USB-8451?
    How can I change it to higher values?
    Thank you very much for your support!
    Message Edited by UnexpectedLifeForm on 02-19-2007 09:48 AM

    Dear Member,
    That's right. If somebody encounter this problem again.
    You should contact your local NI branch that will install the new firmware
    version (that works with the last driver version)
    Best regards,
    Nick_CH

  • I want to set dynamic customer credit limit for a customer

    Hi,
    I want to set a dynamic credit limit for a customer which should trigger during the time of Sales Order Creation.
    Can anyone please let me know the settings one has to do to implement this process in the system ?

    Hi Below is the whole process for confign.
    1. Transaction OB38
       Check which credit control area is assigned to the company code.
       Company code:
       Credit control area:
    2. Transaction OVFL
       Check which credit control area is assigned to the sales area.
       Sales area:
       Credit control area:
    3. Transaction XD02 or VD02
       Check which credit control area is assigned to the payer.
       Payer:
       Credit control area:
    4. Transaction SE37
       Is user exit EXIT_SAPV45K_001 being used?
    5. Transaction OBZK
       For the settings under items 2 - 4, field "All company codes" must be marked in Transaction
       OB45, or the credit control area must be entered under the relevant company code in table
       T001CM of the credit control areas allowed.
       Company code:
       Credit control areas allowed:
    6. Settings for the credit checks
    7. Transaction OVAK
       Which settings do exist for the sales document type used?
       Sales document:
       Check credit:
       Credit group:
    8. Transaction OVAD
       Which settings do exist for the delivery type used?
       Delivery type:
       Credit group for delivery:
       Credit group for goods issue:
    9. Transaction OB01
       Credit management/Change risk category
       Definition of the risk category for each credit control area. This risk category can be
       assigned to a credit account by using Transaction FD32.
    10. Transaction OVA8
        Here, the individual credit checks for key fields
        o credit control area
        o risk category
        o credit group are set. Take these key fields from the above settings and go to the detail
          screen. In particular, check whether fields "Reaction" and "Status/block" are set
          correctly. To carry out follow-up actions in case of a credit block, the credit check
          status must be set (field "Status/block").
    11. Transaction FD32
        Credit master data for the payer of the relevant document.
        Credit account:
        Credit limit:
        Risk category:
        Currency:
    12. Settings for updating the credit values Update of the credit values is required for the limit
        check (static or dynamic credit limit check).
    13. Transaction OVA7
        Update of the credit value is active for the corresponding item type if the check box is marked. This field corresponds to 
        field "Active receivable" in Transaction VOV7.
        Item type: 
        Active receivable:
    14. Transaction V/08, Pricing
        In the pricing procedure used for pricing, subtotal "A" must be entered in a line for
        determining the credit value (mark the pricing procedure and doubleclick on "Control").
        Usually, the net value plus taxes is used. This way the system is determined to use this
        subtotal for credit pricing. The credit price is stored in field VBAP-CMPRE and used for
        update and credit check.
        You can find the used pricing procedure of the order under "Item -> Condition -> Analysis".
        Pricing procedure:
        Line with subtotal = 'A':
    15. Transaction OB45
        Which update group (field "Update") do you use in the relevant credit control area? The
        default setting is "12". If you use another update group, check whether this is fine with
        you. If you open an OSS message, please tell us the alternative update group.
        Credit control area:
        Update:
    16. Transaction OMO1
        Which kind of update did you choose for structure S066? 
         In any case, "Synchronous update (1)" has to be chosen as the kind of update. 
         All other settings will lead to errors.
    Regds
    MM

  • Maximum time/size limit for Beehive Conference recording

    Hi, What is the maximum time/size limit for Beehive Conference recording?
    Thanks
    Chinni

    Looks like I found the probable location of this size limit.  Looking at the web.config file in the
    ExchServer\ClientAccess\Sync folder there is an entry for "MaxDocumentDataSize".  THe value is currently set at 10240000:
    <add key="MaxDocumentDataSize" vaulue ="10240000">
    So this is 9.75 MB or there about, which sounds about right.  I will try increasing this limit at some point to verify.
    Can anyone confirm this?

  • BPC: SOA and setting connection time outs in BPC

    Hi All,
    can any one explain SOA architecture of BCP and how it improves performance?
    My understanding of SOA arcitecture is it breaks down large application into small modules called services.
    Here what are the services it is refering to?
    And in SOA arcitecture, is the client connected to server only when it requests for a service and connection terminates after the service is provided?
    If that is the case, what is the need for setting connection time outs to improve BPC performance.
    Any Help is Greatly appreciated.
    kranthi kumar

    SOA = services oriented architecture
    is a method for systems development and integration where functionality is grouped around business processes and packaged as interoperable services. SOA also describes IT infrastructure which allows different applications to exchange data with one another as they participate in business processes. The aim is a loose coupling of services with operating systems, programming languages and other technologies which underlie applications.[1] SOA separates functions into distinct units, or services[2], which are made accessible over a network in order that they can be combined and reused in the production of business applications.[3] These services communicate with each other by passing data from one service to another, or by coordinating an activity between two or more services. SOA concepts are often seen as built upon, and evolving from older concepts of distributed computing[3][2] and modular programming.
    So SOA is not implemented for performances reason and it is more for integration.
    Regards
    Sorin Radulescu

  • Time out parameters for ABAP and JAVA instance

    Hello All,
    We are looking for Time out parameters for our ABAP and JAVA instances.
    As users are complaining that they are getting time out error
    while they are trying to access Cprojects from Portal.
    I was able to check/collect the ABAP instance parameters from SMICM Tcode.
    Can anybody tell me which parameters we need to look for JAVA instance.
    Thanks in advance.
    Regards,
    Amber S

    jstart/shutdownTimeout
    (jstartup/shutdown_timeout)
    Specifies the shutdown timeout, i.e. the grace period for the AS Java instance to shut down before the Java process terminates itself.  Unt is in Seconds. Default is 120
    j2ee/ms/connectTimeout
    (jstartup/wait_for_scs)
    Specifies the timeout for the first connection to the message server. The AS Java instance fails to start if this timeout expires.Unt is in Seconds.Default is  60
    j2ee/ms/reconnectTimeout
    (jstartup/wait_for_reconnect)
    Specifies the timeout for the reconnecting to the message server.The AS Java instance shuts down when this timeout expires.Unt is inSeconds.Default is  3600 (one hour)
    Thanks

  • Time out period for PO approvals in worklist

    Hi all,
    Can any one know how to check the time out period for PO approvals in worklist other thant workflow builder like from system adminstrator or a query etc.,
    Thanks in advance,
    Regards,
    Pramod

    Hi,
    The following note might solve your problem :
    1330433.
    Thanks and Regards,
    Vignesh Ravikumar

  • Need to increase the Time out  parameter for executing BI queries

    Folks,
    We are publishing BI Query on portal , we are getting Time out error while executing the quries , please let me know how to increment the time out parameter
    Thanks
    Manish

    Hi Manish,
    Try this link
    Time out time
    Cheers....

  • Time out condition for FTP parameters in communication channel

    Hi
    Could you please tell what should be the maximum limit for time out condition in receiver file communication channel for FTP.
    it should be either 120,90 or 60 seconds or can we exceed time than this?
    Thanks in advance
    Best Regards,
    Harleen Kaur Chadha

    There is no hard limit, but the time limit should be less than the polling interval: if you set the polling interval to 60 seconds, your timeout interval should be less than that value. If you exceed this value, you have the risk of an adapter deadlock (adapter stops polling)
    You can imagine that a timeout interval of 300 seconds would not make much sense.

  • Time out parameters for java servers

    Dear Gurus,
    I'm trying to identify if there are any time out parameters/attributes which can be set for the users at Java level.
    I'm wondering if it's possible to limit a user from running a report/query for a long period of time.
    Or a parameter to limit the number of sessions one user can have.
    The reason I'm asking this is because my java server nodes have experience OutOfMemory errors every once in a while, and this is caused by high workload by the users. I'm trying to prevent or decrease the number of these OutOfMemory errors.
    Appreciate any feedback on this.
    Thanks.
    Regards,
    Keat

    Hi Mark,
    Currently, parameter DefaultExpirationTime = 3600, i think this is okay.
    I've located other parameters which might be related to user/system timeout settings.
    HttpMonitoringCacheTimeoutMillis = 1500
    KeepAliveTimeout = 15
    SessionTableTimeout = -1
    InputStreamAddTimeout = 0
    TransactionTimeout = 0
    sap.defaultMaxNumberOfConnections = 10
    I'm thinking about tweaking these parameters as well.
    Any comments???
    Regards,
    Keat

  • High number of "The connection has timed out" errors. Where do I set the time out period (variable and file name) - windows 7

    I usually use a wireless network at home and have very few time out problems with Firefox.
    I am travelling and using Optus Wireless broadband where the average ping to a site is 700+ms .
    I suspect that this is the cause of the high number of timeouts I am experiencing.
    Optus say there are no problems so I think I will have to set the timeout to a longer period.
    Please advise what variable name/s (and in which file) the timeout is set for LOADING PAGES.
    Thanks in anticipation.
    Greg Atkinson.
    By the way the same is happening in IE8
    and on many sites other than the Yahoo one below.
    ================Full Error Page ==============
    URL is http://au.mg4.mail.yahoo.com/dc/launch?.gx=1&.rand=81jkv757qfdqt
    =========================================
    The connection has timed out
    The server at au.mg4.mail.yahoo.com is taking too long to respond.
    * The site could be temporarily unavailable or too busy. Try again in a few moments.
    * If you are unable to load any pages, check your computer's network connection.
    * If your computer or network is protected by a firewall or proxy, make sure that Firefox is permitted to access the Web.

    Having the same problem 4 out of 5 times I try to navigate to a new site I get the error "connection has timed out".
    My I phone works fine on the same wireless connection so it must be something to do with the computer. The problem occurs on IE, firefox, and google chrome.
    I too would like to know how to how to either fix this problem or failing that to extend the length of time before the connection times out (which is currently only about 5 seconds).
    Please help!
    Thanks in advance

  • Setting application time outs in OC4J

    Our application is deployed in OC4J (Candidate Release). It all works fine except for a small problem. if the application is left running and is accessed from the browser and left alone in the browser for abt 10 mins, and then we proceed we get a null pointer exception. Now we realise that this is a time out problem which occurs in OC4J. Now is there ne way to set up application level timeouts in OC4J ? This would be rather useful :-)
    cheers
    Karthik

    Hi Karthik,
    I don't know the answer to your question but there are two Web
    sites that have the OrionServer documentation available:
    http://www.orionserver.com/docs/index.html
    http://kb.atlassian.com/content/orion/docs/
    Hope This Helps,
    Avi.

  • Need help in setting connection time out in Oracle 9i

    My firewall is causing problems in that it is causing me to have timeout problems when tyring to start my Oracle 9i database.
    The best solution is to reset my connect_timeout taht is to be found in listener.ora. But this has been replaced by initial_retry_timeout (I think) for Oracle 9i.
    initial_retry_timeout is to be found in sqlnet.ora in
    C:\oracle\ora90\networkADMIN\SAMPLE
    it is set to 30
    #name.initial_retry_timeout = 30
    There is another sqlnet.ora file in C:\oracle\ora90\network\ADMIN all these contains is:
    # SQLNET.ORA Network Configuration File: C:\oracle\ora90\network\admin\sqlnet.ora
    # Generated by Oracle configuration tools.
    SQLNET.AUTHENTICATION_SERVICES= (NTS)
    NAMES.DIRECTORY_PATH= (TNSNAMES, ONAMES, HOSTNAME)
    I added the following line to this file restarted my PC but time out still took 30 secs.
    I dont have much experience of databases apart from writing sql and store procedures.
    So I have no idea apart from pure guess work in trying to sort thsi problem out.
    Thanks for any help.
    Tony
    names.initial_retry_timeout = 5

    You do not indicate whether you are using the Oracle Names server. The names.initial_retry_timeout tells Oracle Net how long to wait, in seconds, for a response from an Oracle Names server before it attempts the next in your preferred list. You indicated, however, that you were having a problem with your firewall. The only connection this setting has with a firewall is that the firewall may be causing the connection to the Oracle Names server to timeout. If that is your problem, then adjust the value of this parameter to increase or decrease the delay before Oracle Net attempts the next server in your preferred list. If, on the other hand, your problem is in connecting to a database, then this parameter will have no effect.
    What I do not understand is how your firewall can cause problems with starting your database. Is this a software firewall running on your PC? If so, what program is it? You should be able to setup a rule in the firewall software to permit the connection.
    Kind Regards,
    Russ Cannon

  • Time out issue for many users

    Hello all
    many users reported us TIMEOUT issue in our system
    we wanted to extract the report how many users were faced the same issue and why they have received  400 Session time out error.
    what parameter needs to be adjusted in SRM to avoid the same problem
    any help is appreciated and piece of information on this help .
    Muthu

    Hi Muthuraman,
    The error you are experiencing is caused by the icm/conn_timeout parameter being exceeded. You should increase this parameter to solve your issue. Also there are a number of other parameters that will cause the webdispatcher and ICM to close a connection.
    Please refer to SAP Note [824554|http://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/oss_notes/sdn_oss_bc_cst/~form/handler%7b5f4150503d3030323030363832353030303030303031393732265f4556454e543d444953504c4159265f4e4e554d3d383234353534%7d] for additional information in webdispatcher and ICM timeouts.
    Michael

  • Time out problem for select query

    I am fetching data from BKPF for my report.
    I have written following query.But this query always time out.
    SELECT
        BUKRS
        BELNR
        GJAHR
        BLART
        BLDAT
        BUDAT
        MONAT
        XBLNR
        BKTXT
        WAERS
        KURSF
        HWAER
        FROM BKPF
        INTO TABLE I_BKPF
        WHERE BUKRS IN S_BUKRS
         AND BELNR IN S_BELNR
         AND GJAHR IN S_GJAHR
         AND BLART IN S_BLART
         AND BLDAT IN S_BLDAT
         AND BUDAT IN S_BUDAT
         AND MONAT IN S_MONAT
         AND CPUDT IN S_CPUDT
         AND BSTAT = SPACE.
    So please suggest me solution.

    Hi..
    1) Try to make Some of the Fields such as BUKRS , GJAHR  as PARAMETERS so that ROWS are restrited mostly.
    2) Make fields like BLDAT and BUDAT as OBLIGATORY if possible.
    3) And in the SELECT query add the PACKAGE SIZE addition.
    <b>Reward if Helpful.</b>

Maybe you are looking for

  • Best way to modify Sequential Process Model for report generation.

    I am using the Sequential Process Model in my application and the TestStand Reference Manual, (Figure A-1), clearly shows the following processing sequence: ...<part removed>     Call the Test Sequence     Display the UUT results     Generate a Repor

  • How to use variables in logical file name definition FILE

    Hi Friends, How can I use variables in logical file name definition (tcode FILE). The requirement is to pass value in these variables (based on selection criteria), and use it as part of file name. You quick response will be highly appreciated. Thank

  • Anyone noticed their 24" screen brightness lowered recently?!

    I used to have my brightness (on my 24") set down a few bars because it was so bright on full... Since the apparent release of a new graphics driver, I have had to set my brightness to full. Surely Apple could have made the maximum higher and the low

  • Troubles with BRM Integration (Portal)

    Hi Currently we are Integrating BRM 7.3 with Siebel 8.0 and other third parties with BPEL (SOA Suite 10.1.3.4), in many procesess BRM is the trigger of the message it means that BRM calls a WSDL of BPEL. BRM guys told me that anytime that BRM calls B

  • HOW DO I CREATE A PLAIN IMAGE ON A PANEL

    I want to create a simple image with text on it it and display it on a JPanel. Does anybody know how to do this? Thanks in Advance Colin