Setting QRFC Queue Status to STOP

Hello
We will be scheduling reports in Prod to auto restart stopped outbound and inbound QRFC queues. But before implementing these changes we need to know if these reports are working fine TEST environemnt. Can anyone recommend us a way of setting the Status of QRFC queues to STOP.
Thanks.
Kiran

Thanks everyone !!
We executed a simple scenario where we selected the Sender SOAP of the type EOIO which enabled us to define a specific queue e.g. TEST_QUEUE. In the Receiver SOAP we entered incorrect usrr id which caused the messages to be blocked in the queues. Once that was done we again reset the password to the correct values and ran our reports to restart QRFC inbound queues which helped us verify the auto restart of queues.
Best Regards,
Kiran

Similar Messages

  • Queue status is stopped

    Hi,
    I have a File to Proxy  assync. scenario. The file has been read, and then the message stops in the queue. I checked it on sxmb_moni,  the message is posted on a queue and the queue status is "stopped" (with a red stop button printed on).
    I have already read all the posts about this  and couldn't find any solution... Can anyone help?
    Thanks.
    Shwetha

    Yes connection is set proper now.
    And the scenario involves EOIO
    Since it is EOIO, i would suggest that you see the status of the messages in RWB (it may be in Holding)....if it is Holding then follow the lead given in this blog: /people/stefan.grube/blog/2006/04/27/how-to-deal-with-stuck-eoio-messages-in-the-xi-30-adapter-framework
    Regards,
    Abhishek.

  • Queue status stopped

    Hi All,
    I am trying a file to file scenario. In SXMB_MONI the message status is "scheduled" and the queue status is "stopped".
    I have tried deregistering and registering the queue.
    i also tired to see the error in by double clicking on the queue ID it shows SYSFAIL. when i double click on SYSFAIL it shows a message "XI ERROR Update XI Cache Queue Stopped". for this i have also refreshed the cache. but nothing seems to help.
    Anyone having a clue?
    Thanx in advance.
    Latika.

    Hi Latika,
    Reason,
    http://help.sap.com/saphelp_nw04/helpdata/en/49/e3fb40ef74f823e10000000a155106/content.htm
    1. Try restarting J2EE stack.
    2. One of the reason may be database overflow. In this case also, restart is required.
    3. Check if XIAPPLUSER & XIAFUSER are locked. Also retype the password and try.
    Check out Steve Winkler's response here
    To Be Delivered on Adapter Message for JDBC
    Regards,
    Prateek

  • Why is my HP Deskjet 970C  Print Queue Status  "Stopped" and won't change?

    I recently installed 10.5 Leopard. Hooked up my old HP-970C Deskjet. Used the link: http://www.linuxfoundation.org/en/OpenPrinting/MacOSX/foomatic to get the new HP Driver as recommended. Set up printer with this driver.
    Each time the print command is given (Word Doc or .pdf file) nothing happens. The job is shown in the Print Queue with the Status says "Stopped." Clicking the resume button does not start the printer. Twice more and I get a message that says "Operation Could not be completed. client-error-not-possible."
    Any thoughts on how to work around this?
    Tried the six steps listed at: http://h10025.www1.hp.com/ewfrf/wc/document?docname=c01462601&lc=en&dlc=en&cc=us &lang=en&softwareitem=bi-54970-4&os=219&rule=5837&product=3435684
    Even those great steps did not help. Any other ideas? Thanks!!!

    The short answer is that you have an older HP printer, and have just been bitten by HP's abandonment of older printers on both Leopard and Vista.
    The foomatic drivers should work, though; I used foomatic drivers on my old HP MFD for years. They gave better output than the ones HP shipped, and actually worked in Leopard. I put the HP onto a machine running XP because scanning didn't work anymore on either Vista or Leopard and HP had no intention of fixing it.
    When I see the error you quoted, there are usually three possible causes:
    1 the printer itself has a hardware problem. The fix for that is to buy a new printer, it's not economic to repair a DJ970.
    2 the HP drivers are present on the system and are interfering. The fix for that is to remove the HP drivers and just have the foomatic drivers installed.
    3 the USB cable is bad or loose. The fix for that is to get a new USB cable and make sure that it is securely plugged in.

  • Queue Status is showing Stopped

    Folks,
    I am trying to pass IDOCS from XI and the Queue Status is showing Stopped . I am using two receivers.
    Please let me know how to start the queue.
    Manish

    Still the queue is showing stooped , here is the trace ,
    <i><b>  <Trace level="1" type="B" name="IDX_INBOUND_XMB" />
    - <!--  ************************************
      -->
      <Trace level="1" type="T">User: XIAPPL</Trace>
      <Trace level="1" type="T">Language: E</Trace>
      <Trace level="1" type="T">Correct Version from 2 to 3: 3.X-Data to 4.x-Data</Trace>
      <Trace level="1" type="T">ALE-AUDIT-IDoc-Inbound Handling</Trace>
      <Trace level="1" type="T">IDoc-Inbound-Handling</Trace>
      <Trace level="1" type="T">Syntax-Check-Flag</Trace>
      <Trace level="1" type="T">IDoc-Tunnel-Flag</Trace>
      <Trace level="1" type="T">Queueid</Trace>
    - <Trace level="1" type="B" name="IDX_IDOC_TO_XML">
      <Trace level="1" type="T">Get the Metadata for port SAPST4</Trace>
      <Trace level="1" type="T">Convert Segment-Definitions to Types</Trace>
      </Trace>
      <Trace level="1" type="T">Set Receiver Routing-object</Trace>
      <Trace level="1" type="T">Exit Function IDX_INBOUND_XMB</Trace>
      <Trace level="1" type="T">COMMIT is expected by application !</Trace>
      <Trace level="1" type="B" name="CL_XMS_MAIN-ENTER_XMS" /></b></i>
    Can anybody let me know what is the problem

  • BW Queue Status Stopped:  SXMB_MONI

    Hi
    I am passing data from XI to BW into a Data Source via Inbound Proxy. The problem is for some of my messages I get the status as Green Flag(Queue Status- Stop)in SXMB_MONI.
    That means all those Messages are not posted to Data source even though they are successfully transferred from XI.
    If I manually try to restart them. It says that the message are already scheduled in Queue. But in Queue there is no entry.
    Should I regenerate my proxy? Even though out of 10 I still have 6 successful Messages and rest 4 as Queue status stopped.
    Can anyone suggest what can be the problem? 
    Regards
    Swetank

    Hi,
    is there any trasaction in BW where you can register your Queues. somthing like sxmb_Adm--> register Queues...
    B'cos this was the same problem that i encountered when i was using another client(105) in XI-IS when executing server proxies. Then the queues in the client system were not registered.
    so check if there is any place in BW system where you can register the queues.
    cheers,
    Siva maranani.

  • Message Status as "Scheduled" and Queue Status "Queue Stopped".

    Hi friends,
    My scenario is from Peoplesoft -> XI -> BI
    Message has reached BI, but in SXMB_MONI, its showing Message Status as "Scheduled" and Queue Status "Queue Stopped".
    How to proceed further ? How can I start that queue ?
    Thanks ain advance,
    Neena John

    Hi Neena,
    Go to SXMB_ADM -> Manage Queues -> Register Queues
    More on queues
    XI :  How to Re-Process failed XI Messages Automatically
    Run the report RSXMB_REGISTER_QUEUES and register the queues
    Run the report RSXMB_RESTART_MESSAGES for restarting ur messages
    Refer this:
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/20bb9649-e86e-2910-7aa9-88ed4972a5f6
    Regards,
    Vinod.

  • Message Status "Scheduled", Queue Status "Queue Stopped"

    Hi friends,
    My scenario is from Peoplesoft -> XI -> BI
    Message has reached BI, but in SXMB_MONI, its showing Message Status as "Scheduled" and Queue Status "Queue Stopped".
    How to proceed further ? How can I start that queue ?
    Thanks ain advance,
    Neena John

    Hi Neena,
    Go to SXMB_ADM -> Manage Queues -> Register Queues
    More on queues
    XI :  How to Re-Process failed XI Messages Automatically
    Run the report RSXMB_REGISTER_QUEUES and register the queues
    Run the report RSXMB_RESTART_MESSAGES for restarting ur messages
    Refer this:
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/20bb9649-e86e-2910-7aa9-88ed4972a5f6
    Regards,
    Vinod.

  • SAP dispatcher status is stopped in Console how can i start it

    Hi All
    Help me out
    *SAP dispatcher status is stopped in Console how can i start it
    Dispatcher turns green to yellow suddenly and status changes to stopped and all WP elemets shows status as ended.
    Alert from Syslog  : SAP Basis System: Message server disconnected
    Tracert : Disp+work.exe
    trc file: "dev_disp", trc level: 1, release: "640"
    Thu Oct 02 12:32:52 2008
    kernel runs with dp version 128(ext=102) (@(#) DPLIB-INT-VERSION-128)
    length of sys_adm_ext is 312 bytes
    systemid   560 (PC with Windows NT)
    relno      6400
    patchlevel 0
    patchno    21
    intno      20020600
    make:      multithreaded, ASCII
    pid        736
    ***LOG Q00=> DpSapEnvInit, DPStart (00 736) [dpxxdisp.c   1100]
         shared lib "dw_xml.dll" version 21 successfully loaded
         shared lib "dw_xtc.dll" version 21 successfully loaded
         shared lib "dw_stl.dll" version 21 successfully loaded
         shared lib "dw_gui.dll" version 21 successfully loaded
    Thu Oct 02 12:32:58 2008
    WARNING => DpNetCheck: NiAddrToHost(1.0.0.0) took 5 seconds
    ***LOG GZZ=> 1 possible network problems detected - check tracefile and adjust the DNS settings [dpxxtool2.c  3886]
    MtxInit: -2 0 0
    DpSysAdmExtInit: ABAP is active
    DpSysAdmExtInit: JAVA is not active
    DpShMCreate: sizeof(wp_adm)          6624     (828)
    DpShMCreate: sizeof(tm_adm)          2219848     (11044)
    DpShMCreate: sizeof(wp_ca_adm)          18000     (60)
    DpShMCreate: sizeof(appc_ca_adm)     6000     (60)
    DpShMCreate: sizeof(comm_adm)          192000     (384)
    DpShMCreate: sizeof(vmc_adm)          0     (320)
    DpShMCreate: sizeof(wall_adm)          (22440/34344/56/100)
    DpShMCreate: SHM_DP_ADM_KEY          (addr: 05270040, size: 2505416)
    DpShMCreate: allocated sys_adm at 05270040
    DpShMCreate: allocated wp_adm at 052717A8
    DpShMCreate: allocated tm_adm_list at 05273188
    DpShMCreate: allocated tm_adm at 052731B0
    DpShMCreate: allocated wp_ca_adm at 054910F8
    DpShMCreate: allocated appc_ca_adm at 05495748
    DpShMCreate: allocated comm_adm_list at 05496EB8
    DpShMCreate: allocated comm_adm at 05496ED0
    DpShMCreate: allocated vmc_adm_list at 054C5CD0
    DpShMCreate: system runs without vmc_adm
    DpShMCreate: allocated ca_info at 054C5CF8
    DpShMCreate: allocated wall_adm at 054C5D00
    MBUF state OFF
    EmInit: MmSetImplementation( 2 ).
    <ES> client 0 initializing ....
    <ES> InitFreeList
    <ES> block size is 1024 kByte.
    Using implementation std
    <EsNT> Memory Reset enabled as NT default
    <EsNT> EsIUnamFileMapInit: Initialize the memory 2450 MB
    <ES> 2449 blocks reserved for free list.
    ES initialized.
    rdisp/http_min_wait_dia_wp : 1 -> 1
    ***LOG Q0K=> DpMsAttach, mscon ( home) [dpxxdisp.c   9719]
    CCMS: Initalizing shared memory of size 40000000 for monitoring segment.
    CCMS: start to initalize 3.X shared alert area (first segment).
    DpMsgAdmin: Set release to 6400, patchlevel 0
    MBUF state PREPARED
    MBUF component UP
    DpMBufHwIdSet: set Hardware-ID
    ***LOG Q1C=> DpMBufHwIdSet [dpxxmbuf.c   1025]
    DpMsgAdmin: Set patchno for this platform to 21
    Release check o.K.
    Thu Oct 02 12:33:38 2008
    ERROR => W0 (pid 1500) died [dpxxdisp.c   12170]
    ERROR => W1 (pid 3796) died [dpxxdisp.c   12170]
    my types changed after wp death/restart 0xbf --> 0xbe
    ERROR => W2 (pid 3548) died [dpxxdisp.c   12170]
    my types changed after wp death/restart 0xbe --> 0xbc
    ERROR => W3 (pid 1464) died [dpxxdisp.c   12170]
    my types changed after wp death/restart 0xbc --> 0xb8
    ERROR => W4 (pid 3368) died [dpxxdisp.c   12170]
    ERROR => W5 (pid 3400) died [dpxxdisp.c   12170]
    my types changed after wp death/restart 0xb8 --> 0xb0
    ERROR => W6 (pid 2620) died [dpxxdisp.c   12170]
    my types changed after wp death/restart 0xb0 --> 0xa0
    ERROR => W7 (pid 380) died [dpxxdisp.c   12170]
    my types changed after wp death/restart 0xa0 --> 0x80
    DP_FATAL_ERROR => DpWPCheck: no more work processes
    DISPATCHER EMERGENCY SHUTDOWN ***
    increase tracelevel of WPs
    killing W0-1500 (SIGUSR2)
    ERROR => DpWpKill(1500, SIGUSR2) failed [dpxxtool.c   2468]
    killing W1-3796 (SIGUSR2)
    ERROR => DpWpKill(3796, SIGUSR2) failed [dpxxtool.c   2468]
    killing W2-3548 (SIGUSR2)
    ERROR => DpWpKill(3548, SIGUSR2) failed [dpxxtool.c   2468]
    killing W3-1464 (SIGUSR2)
    ERROR => DpWpKill(1464, SIGUSR2) failed [dpxxtool.c   2468]
    killing W4-3368 (SIGUSR2)
    ERROR => DpWpKill(3368, SIGUSR2) failed [dpxxtool.c   2468]
    killing W5-3400 (SIGUSR2)
    ERROR => DpWpKill(3400, SIGUSR2) failed [dpxxtool.c   2468]
    killing W6-2620 (SIGUSR2)
    ERROR => DpWpKill(2620, SIGUSR2) failed [dpxxtool.c   2468]
    killing W7-380 (SIGUSR2)
    ERROR => DpWpKill(380, SIGUSR2) failed [dpxxtool.c   2468]
    NiWait: sleep (10000 msecs) ...
    NiISelect: timeout 10000 ms
    NiISelect: maximum fd=1593
    NiISelect: read-mask is NULL
    NiISelect: write-mask is NULL
    Thu Oct 02 12:33:48 2008
    NiISelect: TIMEOUT occured (10000 ms)
    dump system status
    Workprocess Table (long)               Thu Oct 02 07:03:48 2008
    ========================
    No Ty. Pid      Status  Cause Start Err Sem CPU    Time  Program  Cl  User         Action                    Table
    0 DIA     1500 Ended         no      1   0             0                                                             
    1 DIA     3796 Ended         no      1   0             0                                                             
    2 UPD     3548 Ended         no      1   0             0                                                             
    3 ENQ     1464 Ended         no      1   0             0                                                             
    4 BTC     3368 Ended         no      1   0             0                                                             
    5 BTC     3400 Ended         no      1   0             0                                                             
    6 SPO     2620 Ended         no      1   0             0                                                             
    7 UP2      380 Ended         no      1   0             0                                                             
    Dispatcher Queue Statistics               Thu Oct 02 07:03:48 2008
    ===========================
    --------++++--
    +
    Typ
    now
    high
    max
    writes
    reads
    --------++++--
    +
    NOWP
    0
    3
    2000
    8
    8
    --------++++--
    +
    DIA
    5
    5
    2000
    5
    0
    --------++++--
    +
    UPD
    0
    0
    2000
    0
    0
    --------++++--
    +
    ENQ
    0
    0
    2000
    0
    0
    --------++++--
    +
    BTC
    0
    0
    2000
    0
    0
    --------++++--
    +
    SPO
    0
    0
    2000
    0
    0
    --------++++--
    +
    UP2
    0
    0
    2000
    0
    0
    --------++++--
    +
    max_rq_id          13
    wake_evt_udp_now     0
    wake events           total     9,  udp     7 ( 77%),  shm     2 ( 22%)
    since last update     total     9,  udp     7 ( 77%),  shm     2 ( 22%)
    Dump of tm_adm structure:               Thu Oct 02 07:03:48 2008
    =========================
    Term    uid  man user    term   lastop  mod wp  ta   a/i (modes)
    Workprocess Comm. Area Blocks               Thu Oct 02 07:03:48 2008
    =============================
    Slots: 300, Used: 1, Max: 0
    --------++--
    +
    id
    owner
    pid
    eyecatcher
    --------++--
    +
    0
    DISPATCHER
    -1
    WPCAAD000
    NiWait: sleep (5000 msecs) ...
    NiISelect: timeout 5000 ms
    NiISelect: maximum fd=1593
    NiISelect: read-mask is NULL
    NiISelect: write-mask is NULL
    Thu Oct 02 12:33:53 2008
    NiISelect: TIMEOUT occured (5000 ms)
    Shutdown server ...
    DpModState: buffer in state MBUF_PREPARED
    NiBufSend starting
    NiIWrite: write 110, 1 packs, MESG_IO, hdl 3, data complete
    MsINiWrite: sent 110 bytes
    MsIModState: change state to SHUTDOWN
    DpModState: change server state from STARTING to SHUTDOWN
    Switch off Shared memory profiling
    ShmProtect( 57, 3 )
    ShmProtect(SHM_PROFILE, SHM_PROT_RW
    ShmProtect( 57, 1 )
    ShmProtect(SHM_PROFILE, SHM_PROT_RD
    DpWakeUpWps: wake up all wp's
    Stop work processes...
    Stop gateway
    killing process (676) (SOFT_KILL)
    Stop icman
    killing process (924) (SOFT_KILL)
    Terminate gui connections
    [DpProcDied] Process lives  (PID:676  HANDLE:1564)
    waiting for termination of gateway
    NiWait: sleep (1000 msecs) ...
    NiISelect: timeout 1000 ms
    NiISelect: maximum fd=1593
    NiISelect: read-mask is NULL
    NiISelect: write-mask is NULL
    Thu Oct 02 12:33:54 2008
    NiISelect: TIMEOUT occured (1000 ms)
    [DpProcDied] Process died  (PID:676  HANDLE:1564)
    [DpProcDied] Process died  (PID:924  HANDLE:1556)
    DpHalt: cancel all lcom connections
    MPI CancelAll 2 -> 0
    MPI DeleteAll 2 -> 0
    NiIMyHostName: hostname = 'home'
    AdGetSelfIdentRecord: >                                                                           <
    AdCvtRecToExt: opcode 60 (AD_SELFIDENT), ser 0, ex 0, errno 0
    AdCvtRecToExt: opcode 4 (AD_STARTSTOP), ser 0, ex 0, errno 0
    DpConvertRequest: net size = 163 bytes
    NiBufSend starting
    NiIWrite: write 562, 1 packs, MESG_IO, hdl 3, data complete
    MsINiWrite: sent 562 bytes
    send msg (len 110+452) to name          -, type 4, key -
    detach from message server
    ***LOG Q0M=> DpMsDetach, ms_detach () [dpxxdisp.c   9945]
    NiBufSend starting
    NiIWrite: write 110, 1 packs, MESG_IO, hdl 3, data complete
    MsINiWrite: sent 110 bytes
    MsIDetach: send logout to msg_server
    MsIDetach: call exit function
    DpMsShutdownHook called
    NiSelClear: removed hdl 3 from selectset
    MBUF state OFF
    AdGetSelfIdentRecord: >                                                                           <
    AdCvtRecToExt: opcode 60 (AD_SELFIDENT), ser 0, ex 0, errno 0
    AdCvtRecToExt: opcode 40 (AD_MSBUF), ser 0, ex 0, errno 0
    AdCvtRecToExt: opcode 40 (AD_MSBUF), ser 0, ex 0, errno 0
    blks_in_queue/wp_ca_blk_no/wp_max_no = 1/300/8
    LOCK WP ca_blk 1
    make DISP owner of wp_ca_blk 1
    DpRqPutIntoQueue: put request into queue (reqtype 1, prio LOW, rq_id 19)
    MBUF component DOWN
    NiBufClose: clear extensions for hdl 3
    NiBufSetStat: bufstat of hdl 3 changed from OK to OFF
    NiICloseHandle: shutdown and close hdl 3 / socket 1572
    MsIDetach: detach MS-system
    EsCleanup ....
    Thu Oct 02 12:33:55 2008
    ***LOG Q05=> DpHalt, DPStop ( 736) [dpxxdisp.c   8478]
    Good Bye .....
    Trace from WP table DIA 1
    trc file: "dev_w0", trc level: 1, release: "640"
    ACTIVE TRACE LEVEL           1
    ACTIVE TRACE COMPONENTS      all, M

    B Thu Oct 02 12:32:59 2008
    B  create_con (con_name=R/3)
    B  Loading DB library 'C:\usr\sap\SUD\SYS\exe\run\dboraslib.dll' ...
    B  Library 'C:\usr\sap\SUD\SYS\exe\run\dboraslib.dll' loaded
    B  Version of 'C:\usr\sap\SUD\SYS\exe\run\dboraslib.dll' is "640.00", patchlevel (0.19)
    B  New connection 0 created
    M systemid   560 (PC with Windows NT)
    M relno      6400
    M patchlevel 0
    M patchno    21
    M intno      20020600
    M make:      multithreaded, ASCII
    M pid        1500
    M
    M  ***LOG Q0Q=> tskh_init, WPStart (Workproc 0 1500) [dpxxdisp.c   1160]
    I  MtxInit: -2 0 0
    M  DpSysAdmExtCreate: ABAP is active
    M  DpSysAdmExtCreate: JAVA is not active
    M  DpShMCreate: sizeof(wp_adm)          6624     (828)
    M  DpShMCreate: sizeof(tm_adm)          2219848     (11044)
    M  DpShMCreate: sizeof(wp_ca_adm)          18000     (60)
    M  DpShMCreate: sizeof(appc_ca_adm)     6000     (60)
    M  DpShMCreate: sizeof(comm_adm)          192000     (384)
    M  DpShMCreate: sizeof(vmc_adm)          0     (320)
    M  DpShMCreate: sizeof(wall_adm)          (22440/34344/56/100)
    M  DpShMCreate: SHM_DP_ADM_KEY          (addr: 05A70040, size: 2505416)
    M  DpShMCreate: allocated sys_adm at 05A70040
    M  DpShMCreate: allocated wp_adm at 05A717A8
    M  DpShMCreate: allocated tm_adm_list at 05A73188
    M  DpShMCreate: allocated tm_adm at 05A731B0
    M  DpShMCreate: allocated wp_ca_adm at 05C910F8
    M  DpShMCreate: allocated appc_ca_adm at 05C95748
    M  DpShMCreate: allocated comm_adm_list at 05C96EB8
    M  DpShMCreate: allocated comm_adm at 05C96ED0
    M  DpShMCreate: allocated vmc_adm_list at 05CC5CD0
    M  DpShMCreate: system runs without vmc_adm
    M  DpShMCreate: allocated ca_info at 05CC5CF8
    M  DpShMCreate: allocated wall_adm at 05CC5D00
    X  EmInit: MmSetImplementation( 2 ).
    X  <ES> client 0 initializing ....
    X  Using implementation std
    M  <EsNT> Memory Reset enabled as NT default
    X  ES initialized.
    M  calling db_connect ...
    C  Got ORACLE_HOME=C:\oracle\ora92 from environment
    C  Client NLS settings: AMERICAN_AMERICA.WE8DEC
    C  Logon as OPS$-user to get SAPSUD's password
    C  Connecting as /@SUD on connection 0 ...
    C  Attaching to DB Server SUD (con_hdl=0,svchp=040D325C,svrhp=040D3E34)
    C  Starting user session (con_hdl=0,svchp=040D325C,srvhp=040D3E34,usrhp=040DC614)
    C  *** ERROR => OCI-call 'OCISessionBegin' failed: rc = 1033
    [dboci.c      3721]
    C  Detaching from DB Server (con_hdl=0,svchp=040D325C,srvhp=040D3E34)
    C  *** ERROR => CONNECT failed with sql error '1033'
    [dbsloci.c    9753]
    C  Try to connect with default password
    C  Connecting as SAPSUD/<pwd>@SUD on connection 0 ...
    C  Attaching to DB Server SUD (con_hdl=0,svchp=040D325C,svrhp=040D3E34)
    C  Starting user session (con_hdl=0,svchp=040D325C,srvhp=040D3E34,usrhp=040DC614)
    C  *** ERROR => OCI-call 'OCISessionBegin' failed: rc = 1033
    [dboci.c      3721]
    C  Detaching from DB Server (con_hdl=0,svchp=040D325C,srvhp=040D3E34)
    C  *** ERROR => CONNECT failed with sql error '1033'
    [dbsloci.c    9753]
    B  ***LOG BV3=> severe db error 1033      ; work process is stopped [dbsh#2 @ 1195] [dbsh    1195 ]
    B  ***LOG BY2=> sql error 1033   performing CON [dblink#1 @ 419] [dblink  0419 ]
    B  ***LOG BY0=> ORA-01033: ORACLE initialization or shutdown in progress [dblink#1 @ 419] [dblink  0419 ]
    M  ***LOG R19=> tskh_init, db_connect ( DB-Connect 000256) [thxxhead.c   1271]
    M  in_ThErrHandle: 1
    M  *** ERROR => tskh_init: db_connect (step 1, th_errno 13, action 3, level 1) [thxxhead.c   9379]

    M  Info for wp 0

    M    stat = 4
    M    reqtype = 1
    M    act_reqtype = -1
    M    rq_info = 0
    M    tid = -1
    M    mode = 255
    M    len = -1
    M    rq_id = 65535
    M    rq_source = 255
    M    last_tid = 0
    M    last_mode = 0
    M    int_checked_resource(RFC) = 0
    M    ext_checked_resource(RFC) = 0
    M    int_checked_resource(HTTP) = 0
    M    ext_checked_resource(HTTP) = 0
    M    report = >                                        <
    M    action = 0
    M    tab_name = >                              <

    M  *****************************************************************************
    M  *
    M  *  LOCATION    SAP-Server home_SUD_00 on host home (wp 0)
    M  *  ERROR       tskh_init: db_connect
    M  *
    M  *  TIME        Thu Oct 02 12:32:59 2008
    M  *  RELEASE     640
    M  *  COMPONENT   Taskhandler
    M  *  VERSION     1
    M  *  RC          13
    M  *  MODULE      thxxhead.c
    M  *  LINE        9555
    M  *  COUNTER     1
    M  *
    M  *****************************************************************************

    M  PfStatDisconnect: disconnect statistics
    M  Entering TH_CALLHOOKS
    M  ThCallHooks: call hook >ThrSaveSPAFields< for event BEFORE_DUMP
    M  *** ERROR => ThrSaveSPAFields: no valid thr_wpadm [thxxrun1.c   730]
    M  *** ERROR => ThCallHooks: event handler ThrSaveSPAFields for event BEFORE_DUMP failed [thxxtool3.c  246]
    M  Entering ThSetStatError
    M  Entering ThReadDetachMode
    M  call ThrShutDown (1)...
    M  ***LOG Q02=> wp_halt, WPStop (Workproc 0 1500) [dpnttool.c   357]
    Thanks in advance please help me out
    Edited by: sudhakar aleti on Oct 2, 2008 12:54 PM
    Edited by: sudhakar aleti on Oct 2, 2008 12:56 PM

    Hi All please find the result r3trans -d
    4 ETW000 r3trans version 6.09 (release 640 - 28.04.04 - 16:14:00).
    4 ETW000 ===============================================
    4 ETW000
    4 ETW000 date&time   : 03.10.2008 - 11:02:35
    4 ETW000 control file: <no ctrlfile>
    4 ETW000 R3trans was called as follows: r3trans -d
    4 ETW000  trace at level 2 opened for a given file pointer
    4 ETW000  [dev trc     ,00000]  Fri Oct 03 11:02:36 2008                            5494  0.005494
    4 ETW000  [dev trc     ,00000]  db_con_init called                                    40  0.005534
    4 ETW000  [dev trc     ,00000]  create_con (con_name=R/3)                             26  0.005560
    4 ETW000  [dev trc     ,00000]  Loading DB library 'dboraslib.dll' ...                33  0.005593
    4 ETW000  [dev trc     ,00000]  load shared library (dboraslib.dll), hdl 0        139566  0.145159
    4 ETW000  [dev trc     ,00000]      using "C:\usr\sap\SUD\SYS\exe\run\dboraslib.dll"
    4 ETW000                                                                              22  0.145181
    4 ETW000  [dev trc     ,00000]  Library 'dboraslib.dll' loaded                         7  0.145188
    4 ETW000  [dev trc     ,00000]  function DbSlExpFuns loaded from library dboraslib.dll
    4 ETW000                                                                              13  0.145201
    4 ETW000  [dev trc     ,00000]  Version of 'dboraslib.dll' is "640.00", patchlevel (0.19)
    4 ETW000                                                                            2501  0.147702
    4 ETW000  [dev trc     ,00000]  function dsql_db_init loaded from library dboraslib.dll
    4 ETW000                                                                              12  0.147714
    4 ETW000  [dev trc     ,00000]  function dbdd_exp_funs loaded from library dboraslib.dll
    4 ETW000                                                                              18  0.147732
    4 ETW000  [dev trc     ,00000]  New connection 0 created                              13  0.147745
    4 ETW000  [dev trc     ,00000]  0: name = R/3, con_id = -000000001 state = DISCONNECTED, perm = YES, reco = NO , con_max = 255, con_opt = 255, occ = NO
    4 ETW000                                                                              15  0.147760
    4 ETW000  [dev trc     ,00000]  db_con_connect (con_name=R/3)                      12391  0.160151
    4 ETW000  [dev trc     ,00000]  find_con_by_name found the following connection for reuse:
    4 ETW000                                                                              12  0.160163
    4 ETW000  [dev trc     ,00000]  0: name = R/3, con_id = 000000000 state = DISCONNECTED, perm = YES, reco = NO , con_max = 255, con_opt = 255, occ = NO
    4 ETW000                                                                              14  0.160177
    4 ETW000  [dev trc     ,00000]  Found ORACLE_HOME=C:\oracle\ora92 in Registry        796  0.160973
    4 ETW000  [dev trc     ,00000]  -->oci_initialize                                    400  0.161373
    4 ETW000  [dev trc     ,00000]  Client NLS settings: AMERICAN_AMERICA.WE8MSWIN1252
    4 ETW000                                                                           34020  0.195393
    4 ETW000  [dbsloci.    ,00000]  *** ERROR => Cannot connect: TNS-name missing         11  0.195404
    2EETW169 no connect possible: "DBMS = ORACLE                           --- TWO_TASK = ''"
    Thanks
    Sudhakar A

  • How do I set up a filter to stop relayed mail?

    How do I set up a filter to stop relayed mail?
    Unsolicited Bulk E-mail (UBE) is electronic mail sent to large numbers
    of recipients without their knowledge or consent, usually advertising commercial
    products or services. It is the electronic equivalent of paper "junk
    mail", and is commonly referred to as Spam.
    <P>UBE is usually just a nuisance, but the volume of UBE received at a
    certain site can at times become so onerous that business-critical functions
    are affected. This is especially true when UBE is used maliciously
    to produce a denial of service attack, where a mail server is inundated
    with UBE and crashes because of the load. Another common UBE problem
    is when a mail server is used as a relay for UBE, so that a particular
    server spends all its time routing e-mail that isn't destined for its
    users. Some ISPs have reported that their mail servers have been
    hard coded into certain spam programs, so that they are constantly being
    used as a relay. Not only does this slow down their mail service
    locally, but sometimes other ISP's will identify the afflicted ISP as a
    source of spam and begin to block messages, legitimate and spam alike,
    coming from that ISP. ISP's often name UBE as their number one problem,
    preventing them from providing fast, reliable service.
    <P>For a full definition of UBE see http://www.imc.org/uce-def.html
    (Unsolicited Bulk Email: Definitions and Problems).
    <P>Messaging Server 3.5 Hosting Edition supports powerful filtering capabilities
    on messages as they are received by the server. Various criteria
    can be applied to incoming messages, including testing on number of recipients,
    sender domain or IP address, messages being relayed, and more. Messages
    can then be bounced, dropped, or reviewed by an administrator before being
    delivered. Providers can filter out unwanted mail at the source or block
    a third party from using their messaging server for relaying email.
    <P><B>UBE Filters Functionality Overview</B>
    <P>The UBE filter is a plugin for Netscape Messaging Server 3.5. It works
    by examining all incoming mail before it is routed throughout the system
    (to users mailboxes or to other email servers). The UBE filter uses a set
    of rules (also known as filters) to decide what to do with each piece of
    mail. The filters are used to trap specified types of mail.
    Mail that is trapped can be rejected, forwarded to a specific mailbox (e.g.,
    the postmaster), deleted, or altered in some way. Mail that "passes"
    all the filters continues on its normal course.
    <P>Filters can be set up two ways, either using the straight forward Graphical
    User Interface (GUI) or by setting up the filters directly in the filter.cfg
    file. Generally, one would use the GUI interface for simple, one
    line filters. To set up more complicated, multi-part filters, editing
    the <I>filter.cfg</I> file directly would be faster. Both methods
    are accessed via the Messaging Server Admin tool, under Plug-ins.
    The following discussion gives some high level examples of how to set up
    simple filters using the GUI and via the <I>filter.cfg</I> file.
    For detailed information on how to set up and configure the UBE Filter
    plug-in, see chapter 5 of the online help, or http://home.netscape.com/eng/Messaging/guide35/ch5.htm#Controlling
    unsolicited bulk email (UBE).
    <P><B>Setting Up UBE Filters with the GUI</B>
    <P>The following screen shot shows a simple UBE filter being set up using
    the UBE GUI. What is being set up is a filter to check all incoming
    messages to see if they come from a domain that has been a regular source
    of UBE. In this case, the name of the offending domain is "spammer.com".
    So, each message that comes in has its "From" field checked to see if
    it is from "spammer.com". If it is, the action is REJECT, meaning
    the message is bounced back to the sender, with the appended message "I
    don't accept mail from spammer.com".
    <P>
    <BR>
    <P>Any field in the message can be examined, with some of the most popular
    including the Subject, To, and Cc fields. Any regular expression
    can be placed into the Value field, thus allowing the filter to check for
    various conditions, including containment of a particular phrase (e.g.
    Subject includes "make money"), or number of recipients (e.g., if greater
    than 100, REJECT). For more information on how to write regular expressions,
    see http://home.netscape.com/eng/Messaging/guide35/ch5.htm#Controlling
    unsolicited bulk email (UBE)
    <P>There are a number of actions that can be taken on a trapped message.
    The most common are forwarding to a "watchdog" account such as the postmaster,
    rejection, and deletion. But, in addition, programs such as virus
    checking can be run on a message to trap infected messages.
    <P><B>Setting Up UBE Filters by editing the <I>filter.cfg</I> file</B>
    <P>In the above example, the filter that was set up was converted to a
    short filter script that looked as follows:
    <P>Channel-From ".*@spammer.com" REJECT
    "I don't accept mail from spammer.com"
    <P>This can also be directly entered into the <I>filter.cfg</I> file by
    choosing the option "Edit Config File" from the UBE Page. This becomes
    interesting for more complicated filters that require more than one filter
    line. The following example shows a set of filters that were set
    up to check for various conditions. For example, the fifth
    and sixth line down is a filter that checks messages for viruses.
    <P>
    <BR>
    <P><B>Using the UBE Filter for Anti-Relay</B>
    <BR>
    <P>One of the most requested needs of the new UBE filters supported in
    Messaging Server 3.5 is to provide "anti-relay", i.e., to stop UBE which
    is from an outside domain and destined for another outside domain.
    In these cases, the mail is usually UBE and is relaying to hide the source
    of the original spammer.
    <P>There are two possible scenarios for anti-relay. One is where
    there is a separate machine outside the firewall that checks for e-mail
    for its domain. The other scenario is when there is only one machine
    handling both internal and external traffic.
    <P><I>Scenario One: Separate machines used for internal and external
    mail</I>
    <P>Outside of the firewall are mail servers that handle all incoming mail
    from the internet. Internal users connect to mail servers inside
    of the fire wall. The scenario looks like this:
    <BR>
    <P>What we want to allow is users 1 and 2 (U1 and U2) to send mail anywhere
    but X1 and X2 should only be allowed to send mail to our servers.
    <P>Solution:
    <P>On the External Mail Server create a filter script that checks the Channel-to
    header for domains that are internal to us. Allow these through and
    reject all other mail. E.g., the filters would look as follows:
    <BR>
    <UL># if the mail is bound for domain1 or domain2 then exit the script
    (and allow the mail to continue)
    <BR>Channel-To "domain1.com" EXIT
    <BR>Channel-To "domain2.com" EXIT
    <BR># otherwise reject it outright ($ANY means any header and .* means
    it has any text)
    <BR>$ANY ".*"
    REJECT "This machine only accepts mail bound for domain1.com or domain2.com"</UL>
    We don't need to do anything on the internal server since only our users
    can get to it (because of the firewall) and we want to allow them to send
    and receive any and all mail.
    <BR>
    <P><I>Scenario 2: Single machine used for internal and external mail</I>
    <P>In this scenario the same machine is used for both internal and external
    connections. The problem we face here is that we need to allow the
    local users to send mail outside our domains but not allow external users
    to do the same. Note: This set up is not generally recommended, since it
    makes the Messaging Server open to external attacks.
    <BR>
    <P>Here, we want to allow U1, U2 and U3 to send anywhere and X1 and X2
    to send to domain1 or domain2 only.
    <P>Solution:
    <P>The solution in this case is to put the same script as scenario 1 on
    the server but pre-pend it with lines that check for a connection from
    the internal domains. If the connection is from our users it must
    be from certain IP addresses, say 128.128.128.* or 128.128.129.*, so we
    look for that. If it's not from one of these two IP addresses, then
    it must be from outside and we apply the same logic as in scenario 1.
    <BR>
    <UL>#if the connection is from our internal domains then exit the script
    (and allow the mail to continue)
    <BR>Host-From "128\.128\.128\." EXIT
    <BR>Host-From "128\.128\.129\." EXIT
    <BR># if the mail is bound for domain1 or domain2 then exit the script
    (and allow the mail to continue)
    <BR>Channel-To "domain1.com" EXIT
    <BR>Channel-To "domain2.com" EXIT
    <BR># otherwise reject it outright ($ANY means any header and .* means
    has any text)
    <BR>$ANY ".*" REJECT "This machine only accepts mail bound for domain1.com
    or domain2.com"</UL>

    I agree anti-relay can be using UBE feature. However, there is serious problem in reject the spam mail. My nms is using UBE feature to stop spam mail. According to the work flow of the UBE, the mail is received by nms completely and UBE is going to invesgate the mail address. Although UBE can stop the spam mail, the spam mail have a trouble in returning the mail to the sender. The reason is the sender address is usually not existed in the world. That will cause a lot of mail waiting in the mail queue.
    In my experience, do not use UBE for anti-relay.

  • Messages getting stuck in QRFC Queue

    Hi,
    Today I noticed that a message had gotten stuck with the status "Sheduled for Outbound Processing" (scenario IDOC->XI->File), XI 3.0 SP11.
    This in turn had the effect that the whole QRFC queue got stuck, and all following messages got stuck with status "Sheduled".
    I had to remove the first message from the queue manually so that XI could start to purge the other messages from the queue.
    What could be the reason for the first messages getting stuck with this status ("Sheduled for Outbound Processing")?
    The message was very small, just a couple of lines. One thing that comes into mind, is that XI received 4 IDOCS for the same interface, within one second. These 4 messages were assigned to different queues, but one of them got stuck. Could there be problems with XI when several messages arrive on the same interface within a very short time?
    Is it possible to use Alerts to detect this kind of problem in the future? As I have understood, Alerts only handle XI "errors", but according to XI, this message did not have an "error status", it just had the status "Sheduled for Outbound processing"..
    Thanks for any help,
    Hans

    Hi,
    If the message got struck in Queue, you try to activate the queues in smq2 to reprocess the data instead of deleting it. This is the final solution. But you should able to see a dump in ST22 for this problem.
    thanks,
    sasi

  • Server Admin doesn't show Print Queue status

    When I look at my print queues (all 17) under Server Admin, it shows queue name, # of jobs, shared via (IPP & SMB), and printer kind (HP LJ 1022n and HP LJ P2015). It has a column for status, but this is always 100% empty/blank. Also, if I go to the Jobs tab, then I can pick "Jobs on Queue" for all the queues, but the line below for "Queue Status" is again always blank.
    Is there something I can do to get this info to show up in Server Admin? I know that CUPS knows the printer status, as I can go to localhost:631 and see the status in the Printers list and the Jobs list.
    It isn't life threatening. It is just annoying to have to go to the web page when Server Admin -almost- gets me everything I need to diagnose a teacher's printing problem remotely.

    Hi Keith
    You could always consult the Print Service logs. If you set the logging levels to Debug or Debug2 you should get everything. You have to be a bit careful with this as the log can get quite large. Other than that I don’t know of anything that is available out of the box.
    There may be others that can suggest a 3rd party solution that gives you the appropriate feedback you are looking for. Opening port 631 should not be that much of risk I would have thought?
    Tony

  • Troubleshoot-Adapter engine:Error Setting the message status to DLNG failed

    Dear Experts,
    We use SAP RFC- PI-JDBC(MSSQL).  here the Data(message) successfully transfered to mssql table but the status is been set to DLNG failed,  And it finally shown as SYSTEM ERROR.
    QoS required: ExactlyOnce ,  here The Message has got inserted in that particular table and in PI adapter the  status turned to  DLNG faild and the service again tries to send the same message which is not possible becoz the data is set for primary value.
    2010-09-15 09:59:48 Success Message successfully received by messaging system. Profile: XI URL: http://XXXXX:50000/MessagingSystem/receive/AFW/XI Credential (User): YYYY
    2010-09-15 09:59:48 Success Using connection JDBC_http://sap.com/xi/XI/System. Trying to put the message into the receive queue.
    2010-09-15 09:59:48 Success Message successfully put into the queue.
    2010-09-15 09:59:48 Success The message was successfully retrieved from the receive queue.
    2010-09-15 09:59:48 Error Setting the message status to TBDL failed, due to: com.sap.aii.af.ra.ms.api.DeliveryException: Error updating status..
    2010-09-15 09:59:48 Success Delivering to channel: CCR_JDBC_ZZZZZ
    2010-09-15 09:59:48 Success MP: Entering module processor
    2010-09-15 09:59:48 Success MP: Processing local module localejbs/CallSapAdapter
    2010-09-15 09:59:48 Success Receiver JDBC adapter: processing started; QoS required: ExactlyOnce
    2010-09-15 09:59:48 Success JDBC adapter receiver channel CCR_JDBC_ZZZZZ : processing started; party  , service BS_BCP_IMPLOG_ZZZZZ 
    2010-09-15 09:59:49 Success Database request processed successfully
    2010-09-15 09:59:49 Success MP: Leaving module processor
    2010-09-15 09:59:49 Success The message was successfully delivered to the application using connection JDBC_http://sap.com/xi/XI/System.
    2010-09-15 09:59:49 Error Setting the message status to DLNG failed, due to: com.sap.aii.af.ra.ms.api.DeliveryException: Error updating status..
    2010-09-15 10:37:01 Success The message was successfully retrieved from the receive queue.
    2010-09-15 10:37:01 Success The message status set to DLNG.
    2010-09-15 10:37:01 Success Delivering to channel: CCR_JDBC_ZZZZZ
    2010-09-15 10:37:01 Success MP: Entering module processor
    2010-09-15 10:37:01 Success MP: Processing local module localejbs/CallSapAdapter
    2010-09-15 10:37:01 Success Receiver JDBC adapter: processing started; QoS required: ExactlyOnce
    2010-09-15 10:37:01 Success JDBC adapter receiver channel CCR_JDBC_ZZZZZ : processing started; party  , service BS_BCP_IMPLOG_ZZZZZ
    2010-09-15 10:37:01 Error Unable to execute statement for table or stored procedure. 'imp_log' (Structure 'STATEMENT') due to com.microsoft.sqlserver.jdbc.SQLServerException: Violation of PRIMARY KEY constraint 'PK_XXX_log'. Cannot insert duplicate key in object 'dbo.XXX_log'.
    2010-09-15 10:37:01 Error JDBC message processing failed; reason Error processing request in sax parser: Error when executing statement for table/stored proc. 'imp_log' (structure 'STATEMENT'): com.microsoft.sqlserver.jdbc.SQLServerException: Violation of PRIMARY KEY constraint 'PK_XXX_log'. Cannot insert duplicate key in object 'dbo.XXX_log'.
    Thanks in advance for your valuable answer.

    Hi Vinaygam,
    2010-09-15 10:37:01 Error Unable to execute statement for table or stored procedure. 'imp_log' (Structure 'STATEMENT') due to com.microsoft.sqlserver.jdbc.SQLServerException: Violation of PRIMARY KEY constraint 'PK_XXX_log'. Cannot insert duplicate key in object 'dbo.XXX_log'.
    2010-09-15 10:37:01 Error JDBC message processing failed; reason Error processing request in sax parser: Error when executing statement for table/stored proc. 'imp_log' (structure 'STATEMENT'): com.microsoft.sqlserver.jdbc.SQLServerException: Violation of PRIMARY KEY constraint 'PK_XXX_log'. Cannot insert duplicate key in object 'dbo.XXX_log'.
    See above error, It cannot the Duplicate Key in your log table. Duplicate means repeated as a same data.So kindly check once your data.
    IF,I assume your scenario is Synchronous, If you are using any sender JDBC adapter  just check with your Quality of Service and set it to "Exactly once".
    so kindly do it.
    Thank you,
    Sateesh
    Edited by: sateesh kumar .N on Sep 17, 2010 8:17 AM

  • SMQ2 - Found a queue with name "*" and all other queues stuck in STOP state

    Hi all,
    We have a problem on the ECC side, on outbound asynchronous proxies. Sometimes a new queue appears on SMQ2 there with name "", and with status "STOP". At this time, all other queues stuck with STOP status... the only way of resetting all those queues to RUNNING state again is to delete the queue named as ""...
    Some of you has any idea how this queue "*" appears there and stop all other queues?
    thanks
    roberti

    Hi Ravi,
    Is not only about one queue stopped... the problem is this queue named ""... with status STOP, all other queues stops too with it. The only way to make things work again is to delete the queue named as ""... the problem is to discover what or who is creating this stupid "*" queue. I think that this is a procedural error on datacenter, but they are saying is not the case... I'm investigating, but if someone else has any idea about I would appreciate
    thanks!
    roberti

  • Queue status no send or waitupda in SMQ1

    Hi,all:
      Now our BW system can not do delta upload usually.I find some queue status nosend or waitupda in SMQ1 in source system(CRM). How to make them work usually? Can you give me some advices?
    Regaards&Thanks!
    zagory

    hi Zagory,
    which datasource are you using ? 0crm_sales* ?
    have you activate it in BWA5 ?
    take a look oss note 692195-FAQ: Sales Analytics and CRM-BW data Extraction
    Question 3 : The Deltas for my data source are not extracted . What can I do?
    Suggestion 3: Please check the following.
    Please Check if the services have been generated in transaction GNRWB.
    If they are not active(not marked 'X' before their names) then activate the services following the steps here.
    Go to transaction GNRWB
    Select BUS_TRANS_MSG
    Select (on the right, the services) : BWA_DELTA3, BWA_FILL, BWA_queue
    Press Generate.
    Also check  for the following:
    1. The delta should have been initialized successfully.
    2. Confirm that all Bdocs of type BUS_TRANS_MSG
       are processed with success in SMW01.
    3. If there are queues in SMQ1 with erroneous status then activate these queues.
       In Transaction SMQ1 if there are Queues existing with
       names beginning with CRM_BWAn (n is number) then
       activate these queues in the same transaction.
    hope this helps.
    Symptom
    There may be problems or issues related to data tranfer from CRM to BW.
    Other terms
    CRM-BW extraction,upload,initial,delta,full upload ,Sales Analytics,
    Reason and Prerequisites
    There could be errors in customization or program errors due to which
    data may not be transferred or incorrectly transferred to BW.
    Solution
    Question 1 : The Extraction from CRM to BW takes a very long time. What
    can be done? (Performance Issues)
    Question 2 : On executing transaction RSA3 I get records but I find 0
    records when I load data from BW request.(No Data Available).
    How can I extract data in this case?
    Question 3 : The Deltas for my data source are not extracted . What can
    I do?
    Question 4: How can I extract the fields, which are not provided in the
    standard  data source extraction ?
    Question 5: I am unable to extract  user status correctly.What should I
    do?
    Question 6 : What can I  do when the activity/Opportunity/Complaint
    reasons(Code,CodeGruppe,Katalogart)  are not extracted?
    Question 7: What can I do if the deleted opportunities
    are not reflected in BW?
    Question 8: How do I activate the metadata?
    Question 9: I donot get any records for the delta upload of my attribute
    datasource(s).What is to be done?
    Question 10: What do the status BWSTONESYS0 , BWSTONEUSS0,BWSTTECSYS0
    and various other BW status mean ?
    Solutions
    Question 1 : The Extraction from CRM to BW takes a very long time. What can be done? (Performance Issues)
    Suggestion 1: Please implement notes  653645 (Collective note) and
    639072(Parallel  Processing).
    The performance could be slow because of the wrong control parameters
    used for packaging.
    You can change the package size for the data extraction.
    Also note that changing the package size in the transaction SBIW
    would imply a change for all the extractors. Instead, you could
    follow the path in the bw system.
    Infopackage (scheduler)    > Menu 'Scheduler'   > 'DataS. default data
    transfer'   > maintain the value as 1500 or 1000(This value is variable)
    The package size depends on the Resources available at the customer side
    (The no of parallel processes that could be assigned =
    1.5 times the no of CPU's available approx.)
    Question 2 : On executing transaction RSA3 I get records but I find 0
    records when I load data from BW request.(No Data Available)
    Suggestion 2: First check if there are any entries in the table
    CRMD_ORDER_INDEX.Only if there are entries in this table you can
    extract records.
    If this is not the case then,
    It is possible that the user does not have sufficient
    authorities for extraction of  the relevant objects.
    Additionally, please review and implement the following notes
    615670
    161570
    150315
    618953
    If you are in the release 4.0 then
    To do BW extraction with the user please see that the following
    authorization object exists(display mode is enough):
    CRM_ACT, CRM_OPP, CRM_LEAD, CRM_SAO, CRM_SEO, CRM_CO_SE, CRM_CO_SC
    CRM_CO_SA, CRM_CON_SE, CRM_CMP, CRM_ORD_OP, CRM_ORD_LP, CRM_ORD_PR
    CRM_ORD_OE, CRM_CO_PU, CRM_CO_PD, CRM_ORD_PO
    (all these objects are linked to transaction crmd_order).
    Question 3 : The Deltas for my data source are not extracted . What can I do?
    Suggestion 3: Please check the following.
    Please Check if the services have been generated in transaction GNRWB.
    If they are not active(not marked 'X' before their names) then activate
    the services following the steps here.
    Go to transaction GNRWB
    Select BUS_TRANS_MSG
    Select (on the right, the services) : BWA_DELTA3, BWA_FILL, BWA_queue
    Press Generate.
    Also check  for the following:
    1. The delta should have been initialized successfully.
    2. Confirm that all Bdocs of type BUS_TRANS_MSG
       are processed with success in SMW01.
    3. If there are queues in SMQ1 with erroneous status then activate
       these queues.
       In Transaction SMQ1 if there are Queues existing with
       names beginning with CRM_BWAn (n is number) then
       activate these queues in the same transaction.
    4.a)If required activate the datasource
        Go to transaction BWA5   > select the required datasource and
        activate.
    4 b) The Delta may not be active ,activate the delta in BWA7 by
      selecting the name of the datsource and pressing the candle icon for
      'activate delta'.
    5. In BW system
       Go to transaction RSA1   > modeling   > infosources   > select the
       infosource   > right mouse click on the selected
       infosource   > choose option replicate datasource
        Activate the infosource.
    6. Go to the scheduler for the infosource   > select delta  in the
        update  >choose the option PSA only (in the Processing tab)
        > start immediately
    Check the entry in the RSA7 in the OLTP(CRM system)
    Question 4: How can I extract the fields, which are not provided in the standard  data source extraction .
    Suggestion 4: Follow the steps mentioned below.
    1. Enhance Extract Structure with the required fields. (Create & include
       an append structure to the extract structure via transaction RSA6).
    2.a) Release the fields of the append  for usage. (  To do this, double
       click on the Datasource and remove the flags in the column 'Hide
       Field' for all fields of Append. )
    2.b)If the new fields cannot be seen in the extract structure of
        the transaction BWA1 then change and save the datasource, and then
        activate it in RSA6.
    3. Define your mappings in BADI (CRM_BWA_MFLOW) to fill these fields.
    Goto SPRO .
    Follow the path ->
    SAP Implementation guide ->Implementation with other mySAP components ->
    Data transfer to the Business Information Warehouse->
    Settings for the application specific datasources (CRM)->
    Settings for BW adapter->
    Badi :BW adapter :Enhancement of datasources in messaging flow.
    4. Replicate the new Datasource to BW.
    5. Expand the Communication Structure in BW.
    6. Maintain transfer Rules for the new Datasource.
    7. Activate the trasfer rules and perform the upload.
    Question 5:  I am unable to extract  user status correctly.What should I
    do?
    Suggestion 5 :Check the following notes
    531875
    616062
    713458
    700714
    765281
    Question 6 : What can I  do when the activity/Opportunity/Complaint
    reasons(Code,CodeGruppe,Katalogart)  are not extracted.
    Suggestion 6 :Check the following notes
    481686
    516820
    603609
    617411
    711146
    Question 7:Deleted opportunities are not reflected in BW.
    Suggestion 7: Check the note 706327.
    Question 8: How do you  activate the metadata?
    Suggestion 8:CRM BW adapter meta data has to be activated first before
    it is available in the system. You can use Transaction BWA5 to copy the
    meta data for selected DataSources. You can reach the transaction via
    the IMG maintenance 'SAP Reference IMG -> Settings for SAP Business
    Information Warehouse -> Activate BW Adapter Meta Data'. For more
    information, see the documentation on the IMG activity 'Activate BW
    Adapter Meta Data'.  (Note 432485)
    Question 9: I donot get any records for the delta upload of my attribute
    datasource(s).What is to be done?
    Suggestion 9: In case of attribute datasources, it is possible that the
    entry for the GUID is missing in the table SMOXAFLD.
    If , for example the datasource 0CRM_OPPT_ATTR is not giving deltas
    then you can follow the steps:
    1)If Delta process is active for the attribute datasource e.g.
         0CRM_OPPT_ATTR,  then stop the delta process in the BW
         system 
    2) In the CRM system, Make the entry in the table SMOXAFLD
       for the datasource with the Key
       as  0CRM_OPPT_ATTR     GUID 3) Save the entry.Activate the datasource                           4) Check that the above entry is replicated in smoxafld_s also    after this.               5) Create a transport request manually for the following    object             R3TR   SMO4   0CRM_OPPT_ATTR    
    Question 10: What do the status BWSTONESYS0 , BWSTONEUSS0,BWSTTECSYS0 and various other BW status mean ?
    Suggestion 10: The BW status are used to extract system and user defined
    status.
    The BW status are defined in the customization settings in SPRO.
    Check for-> Status Concept for BP/Product/CRM objects
    Here goto-> Process user status You will find the documentation attached here for the user status. Going inside the transaction you will find the status groups USS0, ZIOP,ZMOP etc. The names of the various BW status are derived from this For ex. BW + ST+ One + USS0 gives the name of the field BWSTONEUSS0 or BWST + ONE + ZMOP = BWSTONEZMOP (Master opportunity values) (which means BWST + (status group name) + status object group name) Double clicking on any of the object groups will take you to the values that these status can have . For ex. BWSTONEUSS0 in your system can have values E001 ,E002,E003,E007 which will be shown in RSA3 as BW status values 1,2,3,7, respectively.
    Similarly we have Goto -> Process system status (in SPRO). Here you can get the values for the system status in exactly the same way as BWSTONESYS0(Lifecycle status) , BWSTTECSYS2 (Error) etc. In RSA3 you get the names as BW status, To know which corresponds to which status here,Goto the record list in RSA3 . Here goto Settings - Layout -Current . Right click -> Press Show technical field names . You will be able to see the BW status names and will be able to adjust the layout accordingly.

Maybe you are looking for

  • How to remove esclamation mark from itunes

    how to remove esclamation mark from itunes???

  • BAPI  for  FB09

    Hi Guys, Are you aware of a BAPI which can be used instead of doing a BDC on transaction FB09? This is "Change line items". Actually, Recording of Transaction FB09 is not coming similar for diffrent line items. Please advise. Thanks.

  • How to Analyse  Trace Files?

    Hi, Can anybody let me know how to analyse the downloaded tracefile. (From ST05). Any links or materials on this matter will be of great help as analysis of trace file is a urgent need for me. -B S B Points assured for useful tips.

  • How to know where my iphone5 bought ?

    How to know where my iphone5 bought?

  • Datapump Export Error

    Hi All, I am using oracle database 10.1.0.4.0 - 64bit on solaris9. While exporting whole database through expdp i got following error: ORA-39125: Worker unexpected fatal error in KUPW$WORKER.UNLOAD_METADATA while calling DBMS_METADATA.FETCH_XML_CLOB