Setup table and delta mechanisim

Hi,
Can anyone explain in detail setup table concept in LO extraction and
Delta mechanisim?
Sridhar

Hi
LO Cockpit Step By Step
Here is LO Cockpit Step By Step
LO EXTRACTION
- Go to Transaction LBWE (LO Customizing Cockpit)
1). Select Logistics Application
       SD Sales BW
            Extract Structures
2). Select the desired Extract Structure and deactivate it first.
3). Give the Transport Request number and continue
4). Click on `Maintenance' to maintain such Extract Structure
       Select the fields of your choice and continue
             Maintain DataSource if needed
5). Activate the extract structure
6). Give the Transport Request number and continue
- Next step is to Delete the setup tables
7). Go to T-Code SBIW
8). Select Business Information Warehouse
i. Setting for Application-Specific Datasources
ii. Logistics
iii. Managing Extract Structures
iv. Initialization
v. Delete the content of Setup tables (T-Code LBWG)
vi. Select the application (01 u2013 Sales & Distribution) and Execute
- Now, Fill the Setup tables
9). Select Business Information Warehouse
i. Setting for Application-Specific Datasources
ii. Logistics
iii. Managing Extract Structures
iv. Initialization
v. Filling the Setup tables
vi. Application-Specific Setup of statistical data
vii. SD Sales Orders u2013 Perform Setup (T-Code OLI7BW)
        Specify a Run Name and time and Date (put future date)
             Execute
- Check the data in Setup tables at RSA3
- Replicate the DataSource
Use of setup tables:
You should fill the setup table in the R/3 system and extract the data to BW - the setup tables is in SBIW - after that you can do delta extractions by initialize the extractor.
Full loads are always taken from the setup tables
1. Data Flow
Relevant T-Codes
a) Initializtion
LBWE: Maintain Extract Structure, DataSource, Active Status, Job Control, Update Mode
SBIW, then follow tree menu path: Settings for App-Specific DS(PI) -> Logistics -> Managing Extract Structures -> Initialization -> App-Specific Setup of Statistical Data -> Choose XX Application  -> Delete/Fill Setup(reconstructing) Table content
RSA3: Check content of setup table
b) Delta upload
SM13: Display update table/Extraction Queue content
RSA7: Display Delta Queue content
Edited by: Tapashi Saha on Jul 24, 2008 7:33 AM

Similar Messages

  • How to fill setup table and initialization

    Hi,
    Can any body send me the document for filling the setup tables and initialization ?
    My mail id is [email protected]
    Regards,
    Viren.

    Hi
    Please sent that doc. to me also.
    [email protected]
    Regards
    Swetha

  • Step by step process of filling setup table and Infocube in r3 and bi syste

    Hi Expert,
                    Anyone can tell me step by step process of filling setup table and Infocube in r3 and bi system.
    Thanks and Regards
    Lalit Kumar

    Hi,
    Refer the BI Preconfigured Scenarios from help.sap.com.
    http://help.sap.com/bp_bw370/html/index.htm
    Regards,
    Hari.

  • Filtering Setup-Table and same filtering for Delta-Queue needed

    Dear All,
    I'm looking for the best solution to do the filtering for the delta-queue.
    In program RMCVNEUA I'm filtering (excluding specific SalesOrg) data for the setup-table creation. I'm loading these data to the BW system.
    BUT now my issue is, that with the delta-queue I'm getting also data for the SalesOrg I have excluded in the setup-table, as I have no filter for the delta-queue.
    My Question: Where/How to filter by the same criteria the entries for the delta-queue?
    Thanks for your support,
    Peggy
    some more details: Application 11; Queue-Name MCEX11; using 2LIS_11_VAHDR, 2LIS_11_VASTH, 2LIS_11_VAITM, 2LIS_11_V_SSL

    Dear Arvind,
    if there is no way in R/3 the solution must be in BW, but how exactly should that look like in the best/smartest way?
    Let us look in detail at an Example:
    DSO 0SD_O03 is getting data from 2LIS_11_VAHDR and 2LIS_11_VASTH.
    1) For VAHDR I have the chance to delete not needed VKORG already in the InfoPackage, or load first to PSA and than filter in DTP or delete in Startroutine in Transformation.
    2) BUT for VASTH, which has no VKORG information at all, I'm only able to delete the Dataset after it's loaded/activated in the DSO, as the rubbish-Dataset won't have any 0SALESORG. How to do that?
    Thx,
    Peggy

  • Data in setup tables and qued delta

    Hi Samuris'
    How can I see  1. the data in setup tables  2. Data in qued delta
    3.From which table(in R/3)  the data is extracted when we schedule a IP for a delta.
    Do we have any transaction code to view 1,2.
    Could anyone let me know exact flow of data when a request is raised from BW.I mean if it is a full load request,from which table in R/3, data gets captured.Also if it is delta load request,from which table in R/3, data gets captured.
    Any help is appreciated,
    Thanks in Advance!
    James

    Hi,
    first it depends on the data source....
    I guess you are talking about LO DSources.
    1. you can open the table itself (usually MCaax_SETUP, e.g MC03BF0SETUP) but this will be raw data, like in a trfc LUW); otherwise call transaction RSA3 with your LO datasource in full mode and you'll see the data as it will be extracted to BW.
    2 call SMQ1, double click MCEX03 for instance, again the queue name in the next screen, you'll see pending transactions (LUWS) to be updated in the BW delta queue, double clicking the TID will lead you to the data in the transaction...
    The corresponding table is ARFCSDATA and it is populated when, in our example, a material document is commited.
    3. it depends on your DSource: LO datasources will take their data from ARFCSDATA, other might extract their data directly from several DB tables...
    hope this helps...
    Olivier.
    Message was edited by:
            Olivier Cora

  • What are setup tables and why do you need to run it

    Hello Gurus,
    I know the steps for setting up the LO cockpit exactors.
    My question is what are the parameters that you feed into the Setup table filling screen --- like the doc numbers, start date and end date.
    Why do we have to run the setup tables?
    If I give the start date for setup table run for SD as 08/24/06 and end time Nill and others parameters blank, then would the set up job run for ever. Is this how you set it up in production environment.
    Does setup mean, bringing the data from application table to extraction structructure?
    Regards
    Simmi

    Hi,
    Look at the threads below :
    SetUp Tables
    setup tables
    setup tables
    setup tables
    Cheers,
    Kedar

  • Statistical Setup Tables and Full Extractions

    For Full Extractions what is the relationship with the statistical setup tables i.e. no of records in the table = no of records to be extracted? Thanks

    Hi,
    The relationship is 1 -> 1 you  have to fill the setup table, the full load only reads this structure. So if you would like to load a 2LISxx full load every night, you have to delete and refill the setup table in R/3.
    Kind regards, Patrick Rieken.

  • Question regarding deltas and filling of setup tables

    Hello Friends,
    We are using the Sales Order Item Datasource 2LIS_11_VAITM. We have transported it to BI Production. We have initialized the delta and the deltas are running for the past 3-4 months.
    Now we had a new requirement which was getting satisfied by the Sales Order Header and Sales Order Header Status DataSources, 2LIS_11_VAHDR & 2LIS_11_VASTH respectively.
    Now we wan to transfer both these (header & header status) DataSources to BI Procution. My question is:
    1) Do we have to refill the setup tables again in R/3 for the Sales (11) application?
    2) Do we have to reload the entire Sales data again from scratch.
    3) Is there any way to transport the 2 new DataSources to BI Production and without disturbing the already running deltas of Sales Order Item Datasource?
    Regards,
    Prem.

    Hi,
    1) Do we have to refill the setup tables again in R/3 for the Sales (11) application?.
    Yes you need to refill the setuptables, because if you want to load deltas, you need to do Init then deltas, other wise first time when you are filled setup tables, (first load init with the existing data in setuptables) from that day to till date you can do full then you can set delta.
    It is better and good to fill setup tables and load.
    2) Do we have to reload the entire Sales data again from scratch.
    Any way you need down time to load the other 2 datasources, and also for 11 application you are filling setuptables.So for perfectness it is better to load from first.
    3) Is there any way to transport the 2 new DataSources to BI Production and without disturbing the already running deltas of Sales Order Item Datasource?
    If you transport the new datasources then delta won't distrub in BW. If you did any changes to DataSource and trying to transport it to production then it will give error, because LBWQ and RSA7 will have data so first you need to clear it and then transport it.
    Thanks
    Reddy

  • 2LIS_03_UM - FULL LOAD VIA SETUP TABLE NOT EQUAL TO DELTA

    Hello,
    I try to load stock data with 2LIS_03_UM.
    When I extract data using setup table and full load I don't get the same records as I get with delta load. Although the key figures values are the same, the documents numbers are different. Most documents from delta load are ML (material ledger) documents while documents from full load (via setup table) are mainly FI documents.
    What can be the reason? How can I fix it?
    Thank you,
    Hadar

    Hi,
    Delta load extracts data from Delta Queue based on your update mode selected in LBWE.
    Full Load or Init load extracts data from Setup tables, here if you are extracting data from setup tables ? did you fill the setup tables now or not after deleting the existing data of the setup tables?
    are you getting same values when compare to R/3 and BW data for some document numbers?

  • LIS11 - will fill setup table again conflict with delta?

    Hi experts,
    we are using LIS11 delta mechanism. LIS11 data is used for two different dataflows in BW.
    Because of a delta problem with the R3 enhancements the delta doesn't work properly for one of these.
    For this one we want to do a full load until the problem in R3 is solved.
    Therefore we have to fill the setup tables again each time we want to do a full load.
    My question:
    Does filling the setup tables again conflict with the delta mechanism for the other flow?
    Or will delta continue to work properly?
    Marco

    hi,
    The delta type for all 2LIS_11* DS is ABR--Complete Delta with Deletion Flag Via Delta Queue.
    This means that there will be no conflict of data duplication in case of full repair, the delta is independent of set up tables.
    Delete and reload the setup tables and the delta will not be effected and also the data will also not be duplicated in cube.
    regards,
    Arvind.
    Edited by: Arvind Tekra on May 4, 2011 9:35 AM

  • Enhancing the standard  Data source without deleting setup tables

    Hi all,
    I am in the the Support Project. My requirement is I want to Enhance u201C2LIS_13_VDITMu201D LO- data source with two fields without disturbing the delta.
    Please suggest me how I have to do this.
    As Per my Knowledge ,
    1. we have to delete setup tables
    2. Enhance the data source & re populate the setup tables.
    3. Delete the data in the cube & add the two new fields in the cube & repopulate the cube with new Initial .
    4. after that delta will be enabled through job control.
    But this process is not suitable for our requirement because delta was enabled long back it is going very smooth till date, I donu2019t want to disturb that process.
    So please suggest me is there any other procedure to do this.
    Thanks,
    Kiran Manyam

    Hi,
    If historical data (loaded earlier in to BW) are not required for the two enhance field, then it is not required to deleted the setup table and reload them to BI.
    In this case simply you can follow the following procedure.
    1. Enhance the fields, and update the transfor structure(to unhide these fields). In BI update the required data target with respective IO. and in exit populate the enhance fields. No need to disturb the delta
    2. Replicated the DS in BI and do the mappings in tranformation.
    Here the existing delta is working, and you will be populating the two fields in the exit only.
    Thanks,
    Jugal.

  • Problem while filling the Setup Table for the DS 2LIS_02_SCL.

    Hi All,
    When I am trying to fill the Setup table for the DataSource 2LIS_02_SCL and only for one specific Purchase Order, it is showing me a message like
    u201CDataSource 2LIS_02_ITM contains data still to be transferredu201D
    I have deleted the Setup Table and I want to delete the entries from SM13, but I do not have Authorization.
    Also, here I am trying to fill the Setup Table for 2LIS_02_SCL and not for 2LIS_02_ITM, but the message displayed above is showing as 2LIS_02_ITM DataSource. I think the Setup Table will be same for both the DataSources.
    Waiting for your valuable inputs.
    Thanks in Advance.

    Hi,
    When you want to fill the setup tables first you need to delete setup tables to avoid the duplicate entires in setup tables ( you can delete the setup tables by using t.code LBWG with application no is 02)
    In your case, the data souce is 2LIS_02_SCL for purchasing.
    when you want to delete the setup tables by using t.code LBWG with 02 application no it will delete all the purchasing related data from all the data sources like
    2LIS_02_SCL
    2LIS_02_ITM
    Before the deletion of setup tables you need to clear the delta Queues and stop the V3 jobs, which loads the data to Delta Queues (RSA7) and Update tables(LBWQ).
    you need to run the V3  jobs manually by using LBWE > Job control > and schedule the jobs until the delta queues will get 0 records. that means no data will be available in RSA7 and LBWQ
    go to SM37 to see the jobs LIS-BW-VB_APPLICATION_02,
    once the delta queues gets 0 records by running V3 Jobs manullay.
    Then remove the released state jobs > remove from schedule means delete the jobs in LBWE > Go to job control > you can delete the released jobs.
    Becuase No postings to be done in application tables, while running setuptable filling you should take some down time to fill the setup tables.( OLI*BW)  *=Application number.
    Once you clear the Queues and delete the v3 jobs, then you need to fill the setup tables after deletion of setup tables.
    once you fill the setup tables , by running intialization to BW side the delta Queue is formed for the data source in R3 side
    Now the postings can be done in R3 side, so you need schedule back the V3 jobs, which you already delted from LBWE to load the data from application tables to RSA7 or LBWQ.
    I hope this may help yoou.
    Regards.
    Rambabu
    Edited by: Rambabu velanati on Jun 9, 2010 4:41 PM
    Edited by: Rambabu velanati on Jun 9, 2010 4:52 PM

  • Setup table vs Update table

    Hi,
    What is the difference between the setup table and update table? Kindly clarify.
    I really appreciate all your help. Thanks.
    Regards,
    Jon.

    Hi
    <b>Update Tables :</b>
    Update tables are the intermediate tables which store data read from document tables. The V3 runs collects deltas in form of LUWs from these update tables and populates the delta queues.
    Update tables are use in V3 update scenario . It acts as staging before loading the delta queue . You can thought it as buffer , it continously refreshed , each time the v3 update takes place .Update table is used when u r loading the data through V3 update method . In this scenario it acts as a buffer between the r/3 and delta queue .. Everytime the v3 update takes place this tableis continuously refreshed ...
    Document tables are the actual application tables where the data is posted when you post a document in R/3.
    Examples can be MSEG, VBRK etc.
    Document tables MKPF/MSEG
    Update tables - VBHDR then V3 Update .

  • About setup tables in R/3 system

    Hello BI Gurus,
    During Production Support, if a requirement arises where new fields have to be included in a Datasource that is covered by the LO Cockpit, then in such a case do we need to necessarily delete the setup tables and reload.
    regards,
    gaurav

    Hi Guarav,
    As you need to clear setup tables, before transporting these changes to production system.
    After import changes, need to setup to load historic data into BW.
    Check: [How to retain deltas when you change LO extractor in Production system|http://sapbwneelam.blogspot.com/2007/09/how-to-retain-deltas-when-you-change-lo.html]
    Hope it Helps
    Srini

  • Ways to reduce downtime for filling up setup table

    Hi Experts,
    Can anyone tell me the step by step process so that i can reduce downtime for filling up setup tables?
    I know that setup tables can be filled by considering sales document numbers....but the further steps are not clear with me...........specially with data loadin till PSA and then to ODS/Cube
    So plz throw some light on this.......
    Regards,
    Vaishnavi.

    Hi,
    You will need to fill the set up tables in 'no postings period'. In other words when no trasnactions are posted for that area in R/3 otherwise those records will not come to BW. Discuss this with end user and decide. Weekends are a general choice for this activity.
    You can run them after business hours so that there wont be any transactions, or in the night times or you can do it on week ends so that there is no need to take down time.
    Fill the setup tables with already closed values and then fill up again with open values.This will reduce the down time.
    Initialize  closed periods first in which users wont enter data ( for example in 2007 or 2006), this initializations can be done while users are working. Then the initialize last period at night/weekends.holidays etc.
    If you know documents that are in closed periods, and you are sure that these documents can no longer be changed, you can only fill the SetUp tables for these documents or only for these periods, by continuing to post in open periods. You then initialize only for these intervals, delete the setup table, and only then do you fill the setup table with the rest of the documents  this procedure can drastically reduce the downtimes of your system.
    However, there is a risk that user exits (and in LIS, formulas and conditions) can be used to retrieve documents that are in periods that are already "closed periods".
    One more thing what you need to bear in mind is, to check if there are any Scheduled jobs which are updating the transaction tables, which would definitely cause Data Reconciliation Issues.
    Try Early Delta Initialization
    With early delta initialization, you have the option of writing the data into the delta queue or into the delta tables for the application during the initialization request in the source system. This means that you are able to execute the initialization of the delta process (the init request), without having to stop the posting of data in the source system. The option of executing an early delta initialization is only available if the DataSource extractor called in the source system with this data request supports this.
    Extractors that support early delta initialization are delivered with Plug-Ins as of Plug-In (-A) 2002.1.
    You cannot run an initialization simulation together with an early delta initialization.
    Hope this link may make you clear about Early Delta Initialization
    http://help.sap.com/saphelp_nw04s/helpdata/en/80/1a65dce07211d2acb80000e829fbfe/frameset.htm
    http://www.allinterview.com/showanswers/2907.html
    http://sap.ittoolbox.com/groups/technical-functional/sap-bw/early-delta-initialization-459379
    http://books.google.co.in/books?id=qYtz7kEHegEC&pg=PA293&lpg=PA293&dq=early+delta&source=web&ots=AM1PtX6wcZ&sig=xKOF85Gb8UtszY44zt06K6R0n3M&hl=en#PPA290,M1
    http://www.blackwellpublishing.com/journal.asp?ref=1069-6563&site=1
    EARLY DELTA
    Early delta Initialization
    How To… Minimize Downtime For Delta Initialization
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/5d51aa90-0201-0010-749e-d6b993c7a0d6
    How To Minimize Effects of Planned Downtime (NW7.0)
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/901c5703-f197-2910-e290-a2851d1bf3bb
    Note 753654 - How can downtime be reduced for setup table update
    602260 - Procedure for reconstructing data for BW 
    437672 - LBWE: Performance for setup of extract structures 
    436393 - Performance improvement for filling the setup tables 
    Note 739863
    /thread/756626 [original link is broken]
    Re: How to Setup and INIT from 2LIS_13_VDITM with millions of records
    How downtime can be reduced for setup table update.
    Fill setup tables without locking users
    Initialization Setup Tables.
    Hope this helps.
    Thanks,
    JituK

Maybe you are looking for

  • GL Open Item does not appear in F-03

    Hi Friends, I am trying to clear the GL open items thru F-03, while I see all the open items that appear in Line item display through FBL3N (total 25), out of them only 24 appear in F-03, I can not see the 25th item. I have checked the document in BS

  • Ipod won't show up on desktop or in itunes, but disk utility recognizes it

    Here's one i've been trying to figure out for a while. i have an old 3g (at least, i think that's what it is...black and white display and clickwheel) ipod that I've only been using as an external hard drive for the last year or two. So, there's only

  • HP Officejet Pro 8500 , false paper jam error message, small plastic piece broken

    product : HP Officejet Pro 8500 All-in-One Printer - A909a OS : NA Error : (fake) paper jam on printer screen I made no change before the issue. It occured while printing 2 pages. The first one was ok, the second one never shows. First I spend many t

  • Can't Open Files Or Folders By Double Clicking on Its Icon

    I'm unable to open any file or folder by double clicking on its icon whether the icon is on my desktop or in a folder. For example, I can't open my hard disk or any DMG file on desktop by double clicking on its desktop icon, but I can open it or any

  • ArchiveLink Barcode dialog box

    hello, would anyone be able to tell me how i can get the bar code entry dialog box to appear in the SD module? I have done the following.. SE16 - configured OAD5 - configured OAC5 - configured. I am entering a standard document (OR) through transacti