SFE-2010P Crash on web interface access

Hello!
I have 1 SFE-2010P with latest factory installed firmware 2.0.1.80  3/06/2008.
It's configured to be on access mode for a remote branch.
It has a trunk with other Linksys switch, which has a trunk with a core Catalyst switch.
There are several VLAN's on the switch.
Management IP is on VLAN 201,and has ip 192.168.201.42.
Everything works great until I try to get an access to Web Interface of the switch. From different VLAN and subnet (192.168.3.0/24) I'm connecting through
Catalyst 3750 to 192.168.201.42 (a /24 subnet). I log in as valid user (admin), and when the browser points me to http://192.168.201.42/home.htm
switch REBOOTS!!!!
Telnet (Menu and LCLI mode) works great, and doesn't reboot the switch.
SFE-2010 is a great hardware, and it's a most powerful from Linksys's switches.
So I hope you'll help me.
P.S.
Here is my config:
interface ethernet g1
switchport mode trunk
exit
vlan database
vlan 10,30,108,201
exit
interface ethernet e27
switchport access vlan 10
exit
interface ethernet g1
switchport trunk allowed vlan add 10
exit
interface ethernet g1
switchport trunk allowed vlan add 30
exit
interface range ethernet e(1-12,14-26,28-48)
switchport access vlan 108
exit
interface ethernet g1
switchport trunk allowed vlan add 108
exit
interface ethernet e13
switchport access vlan 201
exit
interface ethernet g1
switchport trunk allowed vlan add 201
exit
interface vlan 10
name pp-a
exit
interface vlan 30
name av
exit
interface vlan 108
name veda8_lan
exit
interface vlan 201
name Management
exit
no ip dhcp snooping verify
interface vlan 201
ip address 192.168.201.42 255.255.255.0
exit
ip default-gateway 192.168.201.12

If the management IP of your switch is 192.168.201.42, then it must be in VLAN 108 and not in VLAN 201 but assuming I didn't get it correctly, it seems that you're in the right track because as soon as you're asking to log-in to the admin page of the SFE switch, it means that you're using the correct and management PC of the switch. I would agree with you, you're supposed to access it and it shouldn't behave that way. Maybe you could still narrow down the setup of you network. I mean, maybe you could try changing the management VLAN or use the computer that is directly connected to that switch while accessing it. Thanks!

Similar Messages

  • Content Library / Web Interface - access issue

    BPC Microsoft 7.5 SP6
    Windows 2008 R2 server
    We have puublished an Excel template as an HTML page to allow (web only users) access to a menuing system and have subsequent access to their individual reports in PDF format. The menu page comes up without errors but I encounter the error "You don't have access" when clicking on a menu option (cells within template). The cells contain an Excel Hyperlink function in conjunction with a EVBNV function to launch this report. (No BPC or excel errors exist within template)
    We have created a virtual directory for BPC application in addition to Reports and ReportServer for Reporting Services. We have modified the Site Settings and Folder Setttings in Reporting Services configuration to allow web users to correct role access.Users can access Reporting services Report url without a problem but the web interface does not want to launch/retrieve a pdf file. We have the correct BPC task capabilities and task profiles assigned, insuring they can access and use the content library.
    Thoughts?
    Thanks in advance.

    It appears there is an issue with EVBNV formula and its ability to dynamically pass parameters in HTML format.
    IM 0003554460/20111

  • SRW224G4P: no web interface access

    Hi to all!
    I've read many ppl having similar problem, but mine is a little bit different.
    The web interface of my switch (SRW224G4P) used to work very well, but since some time it is not possible to access, it sends back a page that contains:
    <html><body><script>window.close();</script></body></html>
    On Safari and IE it closes the window (of course), on Chrome it stays blank.
    If I try to access via HTTPS it raises a problem with certificate, saying the certificate is for sw0.ph.cube.lan (the previous name of the siwtch) and not for sw0.voip.cube.lan (the actual name). I suspected it could be something related to name change, but even going back to the previous setting does not resolve.
    I've tried to reset to factory defaults, even reflashing with the same firmware version, but the problem is not solved yet.
    HW: SRW224G4P
    SW: 1.3.1
    TIA
    Andrea Mistrali

    Hi Andrea
    You have done everything I would have tried, except have you upgrades your Internet explorer to a very recent Version ?
    the datasheet shows that the unit supports only "Microsoft Internet Explorer (version 5.5 or later)" but I am thinking that it works best with  IE6.
    Maybe someone else has a better idea, but try using a IE version 6 and maybe not the more recent versions of IE.
    If that fails, since the product has a "5-year limited hardware warranty with return to factory replacement and 90-day limited software warranty"
    If the problem really is switch software on that switch, it sounds like a case for a replacement.
    Contact the Small Business Support Center via the following URL.
    http://www.cisco.com/en/US/support/tsd_cisco_small_business_support_center_contacts.html
    regards Dave

  • Cisco Prime 2.0 web interface access

    We just installed Cisco Prime Infrastructure 2.0 Express. It seemed to have installed correctly? But Two oddities. First when the system is restarted it takes and inordinate amount of time before the web interface becomes available. Once the web service is responding, it will not except ANY login credentials.
    I can ssh to the instance and using cli, added two additional accounts. All accounts can access the install instance using ssh. None are able to login to the webinterface.
    Thoughts as to what I may have missed?
    Gabe

    Please login to the CLI as admin then execute the command to change the password for the root WebUI acccount
         > ncs password root password Private123
         Loading USER - root
         Validating new password..
         Resetting password ..
         Resetting password  COMPLETED.
         EXECUTION STATUS : Success
    Once you've changed this password please then try to use those credentials to login to
    the WebUI you indicated was presented in your response above.
    Let me know if this does it. If not, we'll need to go a little deeper:::

  • IDS 4125 , web interface access, CLI access, monitoring

    I knew that we can use ciscowork 2000 to monitor IDS.
    1- But can I use Cisco security agent to monitor IDS as well ?
    2- Are there any other software for monitoring IDS beside ciscowork 2000 ?
    3- Does IDS 4125 itself have web interface for monitoring ?
    4- We have got IDS 4125 at work (production line), I tried to access it through web interfaces, I tried all of these without any success:
    https(with s)://192.168.x.x,and https(with s)://192.168.x.x:443, http(without s)://192.168.x.x, I could not, then I tried to access it through console without any success.
    I can telent to it.
    Regards
    Regards

    1) No. CSA is a host based IDS. Do you mean Cisco Security Manager? I'm not positive, but I don't think the CSM supports event monitoring like the old CiscoWorks/VMS did.
    http://www.cisco.com/en/US/customer/products/ps6498/products_data_sheet0900aecd803ffd5c.html
    2)Here are the Cisco tools:
    IDS Event Viewer (free): http://www.cisco.com/cgi-bin/tablebuild.pl/ips-ev
    CSMARS: http://www.cisco.com/en/US/products/ps6241/index.html
    CiscoWorks SIM(netforensics): http://www.cisco.com/en/US/products/sw/cscowork/ps5209/index.html
    Otherwise, just do a google search for "Security Event Management" or similar. The Cisco IDS/IPS has enough market share that most vendors support them.
    3) I'm not familiar with that model. Do you mean 4215? The 5.x version has an event monitoring web interface. I don't remember if the 4.x code does.
    4) By default, the 5.x sensor will be listening on tcp port 443 for https connections and tcp port 22 for ssh connections. telnet is disabled by default. These can all be modified though.

  • SRW2048 Web Interface Access

    How can I access the we interface of this switch if it is configured to get its IP address from the DHCP server? Since it is DHCP I do not know what IP address has been assigned to it therefore I do not know what ip address to enter in the browser.
    Thanks

    Hello, Mr. Berenquel, The MAC should have been on a label on the Back or Bottom of the unit. Do you have access to the Switch? Another option would be to get a console cable and console into the switch. Once you do that you can see the IP address and MAC address.
    Eric Moyers
    Cisco Network Support Engineer
    CCNA, CCNA-Wireless
    1-866-606-1866

  • Prime Infrastructure 1.3 Can't start DB.Can't use WEB interface access

    Hi,
    Suddently, all services at prime infrastructure 1.3 are stopped. It's working fine previously. I try to restart the ncs service also doesn't help.
    here is the ncs status:
    PRIME01/netsvcsdm# ncs status
    Health Monitor is running, with an error.
    initHealthMonitor(): can not start DB
    Reporting Server is Stopped
    Ftp Server is Stopped
    Database server is stopped
    Tftp Server is Stopped
    Matlab Server is Stopped
    NMS Server is stopped.
    SAM Daemon is not running ...
    DA Daemon is not running ...
    Syslog Daemon is not running ...
    status
    PRIME01/netsvcsdm# ncs start
    Starting Network Control System...
    Unable to verify hardware.
    This may take a few minutes...
    Health Monitor is already running.
    Failure during Network Control System startup.  Check launchout.log for details.
    start
    Note: I notice that the MEM LED at light path diagnostics panel components is lit. I check at cisco documentation, it indicate memory error. is it confirmed appliance issue?
    Please advice. Thank you

    Thank you for the reply. sorry for late update.
    1. I try to reseat the memory card, MEM LED from diagnostic panel is not lit anymore. I think it solve the memory problem initially.
    2. I use the following command to refresh the database
    NCS stop
    NCS DB reinitdb
    NCS start
    After reinitdb, I can login to prime infrastructure. it seems like the system is working fine. All of the configuration is gone. So, I proceed to restore the configuration.
    3. Restore configuration
    When I try to restore my configuration, I have the following error.
    PRIME01/netsvcsdm# restore 2013-07-24_PRIME01-130724-1853.tar.gpg repository localftp application NCS
    Restore may require a restart of application services. Continue? (yes/no) [yes] ? yes
    Initiating restore.  Please wait...
      Stage 1 of 9: Transferring backup file ...
      -- complete.
      Stage 2 of 9: Decrypting backup file ...
      -- complete.
      Stage 3 of 9: Unpacking backup file ...
      --complete.
    ERROR : There is the mismatch in the following configuration parameter(s) of this machine when compared to the machine where the backup was generated: DB Memory Target, RAM Size -> can’t restore the configuration due to RAM size different.
    ERROR : This may affect the performance of the current machine. Hence aborting restore process.
    % Application restore failed
    PRIME01/netsvcsdm#
    PRIME01/netsvcsdm# show inventory
    NAME: "PRIME-NCS-APL-K9   chassis", DESCR: "PRIME-NCS-APL-K9   chassis"
    PID: PRIME-NCS-APL-K9  , VID: V02 , SN: KQ7T4TM
    Total RAM Memory: 12141876 kB -> Appliance only detect the RAM memory as 12GB. Our Appliance has 16GB memory. I suspect 1 of 4 memory was spoiled.
    I notice that the prime only detect 12GB RAM instead of 16GB. There is hardware failure (1 of 4 memory is spoil). Unit have to be RMA.
    Thanks,

  • Disabling Networked Printer Web Interfaces

    Hello,
    I did a search with my novice search skills and didn't find exactly what related to my issue. I have multiple virtual print servers on Win08 R2 with networked printers from different manufacturers.  Is there a way other than going to each printer to
    disable web interface access via host name or IP?  I'm thinking possibly via GP.
    Thanks

    Since the Web interface is a device feature and has nothing to do with Windows, that's something you need to configure at the device level.
    Alan Morris Windows Printing Team

  • E4200 Web interface port wont change

    Howdy yall,
    I was wondering if there are any known issues regarding the linksys e4200 web interface accessibility.
    I am trying to configure the web interface for outside access, but i want the port to be: 2000
    So i changed the port, but when i type my external IP in the webbrowser, without a port, i still get the username/password
    prompt window. This is in the standart 80 port, even though i changed the port to 2000.
    Also, when i type my external IP including port number 2000, the connection fails.
    The problem is, the webserver in the router running the web interface, refuses to change to port 2000
    It doesnt matter whether i restart the router after the change, or not.
    Does anyone  have any clue about the root of the problem ?

    Never mind, it appears that for some reason my browsers connect to the routers interface directly. no matter what url i use.
    An online port scan reveiled that the port did in fact change, so there is no problem.

  • When is Linksys going to fix the WPS54g web interface that's crashing?

    Since the last update 6049 in September 2005 which fixed problems but also introduced a new problem. If you used Firefox or Internet Explorer 7 both will completely crash the print server. Now with Internet Explorer 6 it works fine. The problem is you can't get Internet Explorer 6 with Vista, and also Microsoft is updating all Windows XP boxes to Internet Explorer 7 though the auto update. I love the web interface and the Admin tool is not as powerful as the web interface. There has not been an update since September 2005.Personally I use Ubuntu Linux and Firefox started crashing the server immediately with the update , but I needed. It was ok because I had a Windows VM with IE 6, and I figured Linksys wasn't going to give me the time of day. Any workarounds maybe?
    (Edited for guideline compliance. Thanks!)Message Edited by JOHNDOE_06 on 02-21-200709:59 PM
    Message Edited by jerone on 02-22-200701:08 PM
    I ask Johndoe_06 that you not edit this into a question that is not relavent. The problem is a problem that Linksys needs to fix.Message Edited by jerone on 02-22-200701:09 PM
    Message Edited by jerone on 02-22-200701:10 PM

    This is not a security setting problem. Firefox first exposed this problem and now IE 7 is exposing it. The print server should not crash if a web browser is viewing it. No matter if you are under Windows or Linux . I first saw this problem using Firefox under Linux. But IE 6 worked fine under Windows. But now IE 6 is now gone to the way side and both Firefox & IE 7 send commands to access web pages is exposing a serious problem in the WPS54g firmware.Message Edited by jerone on 02-22-200701:10 PM

  • NCS web interface crashed

    Hi,
    I was adding a map in NCS when the web interface crashed. I added 20 so far w/o issues. I refreshed the page and now i cannot access it through the web gui.
    I can access it through ssh and I i did a sh application status NCS. this is what i noticed: NMS Server is stopped
    I did:
    ncs stop
    ncs start
    this is the output for sh application status NCS
    Health Monitor is running, with an error.
    failed to start NCS on startup Health Monitor
    Reporting Server is running
    Ftp Server is running
    Database server is running
    Tftp Server is running
    Matlab Server is running
    NMS Server is stopped.
    SAM Daemon is running ...
    DA Daemon is running ...
    Syslog Daemon is running ...
    status
    Any ideas?
    Regards,
    Eugen

    And root access also works, showing that IP address is ok
    Prime/Admin# root_enable
    Password :
    Password Again :
    Root patch enabled
    Prime/Admin# root
    Enter root patch password :
    Starting root bash shell ...
    ade # ifconfig
    eth0      Link encap:Ethernet  HWaddr 00:50:56:A5:63:46
              inet addr:172.16.220.150  Bcast:172.16.220.255  Mask:255.255.255.0
              inet6 addr: fe80::250:56ff:fea5:6346/64 Scope:Link
              UP BROADCAST RUNNING MULTICAST  MTU:1500  Metric:1
              RX packets:5781 errors:0 dropped:0 overruns:0 frame:0
              TX packets:3335 errors:0 dropped:0 overruns:0 carrier:0
              collisions:0 txqueuelen:1000
              RX bytes:6312015 (6.0 MiB)  TX bytes:586194 (572.4 KiB)
    lo        Link encap:Local Loopback
              inet addr:127.0.0.1  Mask:255.0.0.0
              inet6 addr: ::1/128 Scope:Host
              UP LOOPBACK RUNNING  MTU:16436  Metric:1
              RX packets:491842 errors:0 dropped:0 overruns:0 frame:0
              TX packets:491842 errors:0 dropped:0 overruns:0 carrier:0
              collisions:0 txqueuelen:0
              RX bytes:85107900 (81.1 MiB)  TX bytes:85107900 (81.1 MiB)

  • Problems access to a web application (Web Interface or Web report)

    Hi,
    We found problems with the access to web application. Some users have problems with direct links to the web applications(Web Interface or Web reporting), when they click on the link an error message appears, the message displays the following text:
    "Cannot open file Bex?sap-language=ENbsplanguge=ENcmd=idoc_TE.."
    Clicking in details the message is "No Access to specified file"
    For this users the access to excel reporting is correct, the message appears when they click on the direct web links through the browser or directly in BW system, but if they type the URL they can access. Other users can use the direct web link without problems.
    I highly appreciate any help or idea about how to solve this issue.
    Thanks in advance.

    HI,
    please ask to your basis that check the language of every single user on su01 tx.
    This is the problem i think.
    Natalia.

  • Cisco RM-1252G-A-K9 can't access web interface

    I hope I am in the correct forum for this topic?
    For some reason I cannot access the web interface in order to configure this device. I have it connected to a router (DHCP). The router assigns an IP Address and I can ping it. If I attempt to go to that IP Address in any web browser. the page cannot be displayed. I've reset it several times. I have 2 of these and same problem. Am I missing something obvious? I sure hope so...

    Connecting to the Access Point Locally
    If you need to configure the access point locally (without connecting it to a wired LAN), you can connect a PC to its console port by using a DB-9 to RJ-45 serial cable.
    Follow these steps to open the CLI by connecting to the access point console port.
    Step 1 Connect a nine-pin, female DB-9 to RJ-45 serial cable to the RJ-45 console port on the access point and to the COM port on the PC.
    Step 2 Set up a terminal emulator on your PC to communicate with the access point. Use the following settings for the terminal emulator connection: 9600 baud, 8 data bits, no parity, 1 stop bit, and no flow control.
    Assigning an IP Address Using the CLI
    When you assign an IP address to the access point using the CLI, you must assign the address to the BVI. Beginning in a privileged EXEC mode, follow these steps to assign an IP address to the access point BVI using the console port:
    Command
    Purpose
    Step 1
    enable
    Enter privileged EXEC mode.
    Step 2
    configure terminal
    Enter global configuration mode.
    Step 3
    Interface bvi1
    Enters interface configuration mode for the BVI.
    Step 4
    ip address address mask
    Assigns an IP address and subnet mask address to the BVI.
    Step 5
    end
    Return to privileged EXEC mode.

  • Unable to Access CSACS 5.3 Web Interface...

    Hi Everyone,
    I wanted to note an issue I ran into today with our MS Windows 7 workstations and 2008 servers being unable to access the web management interface on our instance of ACS 5.3 and its solution, which is outlined below:
    ###      The Problem      ###
    When I tried accessing the web management interface on our ACS 5.3 appliance, the browser was unable to connect.  NMS applications showed that the device was up and I was able access it via SSH.  I then tried connecting to 443 via telnet on my workstation and was successful in establishing a connection.  I proceeded to issue the "show application status acs" command showed all associated processes running.  I had a co-worker attempt to access it and he ran into the same issue.  I then proceeded to restart the ACS application by stopping and starting the associated processes.  After the processes were back up, attempts to connect to the web management interface still failed.  I then proceeded to reboot the appliance.  Again, after the applicance and processes were back up, attempts to connect continued to fail.  As a last ditch effort I used a portable version of Firefox to connect and was then successfully able to connect.
    ###       The Source        ###
    After additional troubleshooting, it was discovered that the MS Internet Explorer patch associated with MS Security Advisory 2661254 just so happened to be the culprit.  This restricts the use of certificates with RSA keys less than 1024 bits in length.  The default management certificate just so happens to be 512 bits in length.
    ###          The Fix           ###
    Using FireFox, I navigated to System Administration > Configuration > Local Server Certificates > Local Certificates.  I then proceeded to add a certificate in the following steps:
    Select Generate Self Signed Certificate & click next
    Populate the Certifcate Subject field with the appropriate DN information of the ACS server.
    Change the key length to 1024 or above.
    Check "Management Interface:  Used to authenticate the web server (GUI).
    Check "Replace Certificate".
    Click Finish.
    The ACS server should then generate the new certifcate, replace the existing management certificate, and restart the ACS processes.  After everything is back up, you shouldn't have any issues in accessing the web interface.
    Cheers,
    Dan

    Hello Dan,
    Thank you for trying to share the information you have.
    Note please if you want to share information you can post a document, not a discussion.
    You can convert this discussion into a document from the right pane menu.
    Greetings,
    Amjad
    Rating useful replies is more useful than saying "Thank you"

  • OCA admin web interface - can't access certificate management tab

    Hi there.
    This is very strange, a week a go I could issue certficate requests in the user web interface and then aprove them in the admin web interface.
    Now I can issue certificate requests in the user web interface but when I try to aprove the request by accessing the certificate management tab, the web browser stays a lot of time trying to access the page and timesout with a "cannot display this page" error.
    I've been looking at log files, but untill now, I couldn't find anything. Maybe I'm looking in the wrong files?
    Does anyone had this problem before?
    Thanks and regards,
    Ricardo Vilhena

    When you access the admin page, does it ask to select the certificate you want to use?
    If don't, or you don't see this (in a windows with a list) they you may try to reset OCA, this happens when the certificate is lost or have been disabled, rejected or deleted, and as you dont have anything to use, you can't see the page.
    Hope this helps.
    Greetings.

Maybe you are looking for

  • PO VS PAYMENT TERMS REPORT

    Hi All, Is there any standard report in SAP which can show users po number and payment terms. Thanks, Vishal Pant

  • Changing the owners name...

    hey, just a little thing but is kinda annoying, anyone know how to change the name the ipod is registered to...u know when the ipod is updating in itunes it says "name Ipod"....

  • Previously downloaded 'Mountain Lion' - Need to download again.....How??

    Hi, i downloaded 'Mountain Lion' software for my macbook air earlier this year, through the apple website and paid for the license etc etc etc. Recently my macbook crashed and i have had to reboot it and start again from scratch therefore i only have

  • Help validating param fields with Javascript

    Hi, Rpt Escapes: B4 Form Values, I added a javascript that validates the entered date_ranges(date_from -- date_to) -- must not be > 30 days. If I used that javascript in one of the param fields (web_settings:: Additional HTML = onChange="show_alert(t

  • Can CWM2 API creating dimensions and cube reference a view

    Can CWM2 API creating dimensions and cube reference a view instead of a table. Can the following API reference a view instead of table For creating dimensions CWM2_OLAP_TABLE_MAP.MAP_DIMTBL_HIERLEVEL CWM2_OLAP_TABLE_MAP.MAP_DIMTBL_HIERLEVELATTR For c