Simple question: Is this GLC-FE-100BX-D= 100BASE-BX10-D SFP module for 100-MB ports, 1550 nm TX3/1310 nm RX4 wavelength, 10 km over single-strand SMF  compatible with multimode fiber?
Thanks,

just if the SFP will work on singlemode and multimode fibers
If you have multi-mode (MM) fibre link then you need to use MM SFP.
If you have single-mode (SM) fibre link then you need to use SM SFP.
You can't use MM SFP on a SM fibre link. 

Similar Messages

  • Glc-fe-100bx-d ,crc error with ME 3400 --(ME-3400-24FS-A )

    hi
    when i try to connect (glc-fe-100bx-d) sfp with my cisco switch ME3400 (ME-3400-24FS-A),
    i got this error (
    GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Fa0/15 has bad crc)
    So I try to change the software release   from (Cisco IOS Release 12.2(55)SE) , to (Cisco IOS Release 12.2(40)SE) and (Cisco IOS Release 12.2(58)SE2) ,
    but It give’s same error message .
    Thank You

    This error is due to an unsupported GBIC in the switch, there are a couple of undocumented commands that may work on some switches to allow the GBICs to work, try these commands:
    service unsupported-transceiver
    no errdisable detect cause gbic-invalid
    Failing that you may have to try and find another GBIC that is supported.
    If the Catalyst switch is running IOS 12.2(25)SE and above, the commands are available with the ? before that they are hidden so you won't see them, just enter them and they should be accepted.
    Also bear in mind that they are unsupported for a reason and it probably isn't a good idea to use them in a production network.
    Cisco TAC won't help with any fault finding until they are replaced either.

  • SFP GLC-EX-SMD dont work in C3KX-NM-1G Module on switch WS-3560X-48T

    Hi
    We insert a SFP GLC-EX-SMD in a Module C3KX-NM-1G, in switch ws-3560X-48T, but appear a message " dont supported" and the port remains in error-disable. we probe in the four port of module C3KX-NM-1G.
    In paper from webpage of Cisco, say that is supported this sfp GLC-EX-SMD, but we have to use other IOS 12.2.58.SE, but this ios not exist for these switch.
    The switch have ios 12.2.55.SE5. we need this SFP for a distance over ten kilometer.
    Link when appear data from switch 3560X, sfp and nm.
    http://www.cisco.com/c/en/us/td/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL_6981.html
    My question is. is supported or need extra configuration for that SFP GLC-EX-SMD work in a Module C3KX-NM-1G, in switch ws-3560X-48T?
    Regards

    Same thing. Upgrade the switch to 15.0(2)SE4.
    According to the Release Notes, this SFP is supported on 12.2(58)SE2 but I am no idi0t and I won't recommend anyone using the entire 12.2(58)SE because there are more bugs in this train than the Amazon.

  • Cisco 3845 didn't detect HWIC-1FE and SFP GLC-LHSM

    Cisco 3845 not detect HWIC-1FE and
    SFP GLC-LHSM.
    What is latest IOS which will detect WIC HWIC-1FE , SFP GLC-LH-SM.

    Hi,
    You need a minimum of 12.4(15)T for HWIC-1FE Support on 3845 routers.
    Please refer the below URL for details:
    http://www.cisco.com/en/US/prod/collateral/routers/ps5854/product_data_sheet0900aecd80581fe6_ps5853_Products_Data_Sheet.html
    For the HWIC-1FE and HWIC-2FE the minimum level is Cisco IOS 12.4(15)T.
    Regards,
    Arul
    *Pls rate if it helps*

  • Issue with 3560g sfp GLC-SX-MM connect to 2924C

    I have a 3560g switch. Have gig sfp interface [GLC-SX-MM=] and want to connect to to WS-2924C-XL f0/24 fasteth fiber port.
    I have a patch panel in the middle.
    3560g sfp interface [GLC-SX-MM=]   SC   ---------- ST PP  ST   -------------------------   SC  2924C-XL f0/24 fasteth fiber port
    can I make this work? The lights do not come up. The port are configured correctly. I can not hard code the speed on the 3560 int sfp.

    Unfortunately, you can't directly connect a 1GE GLC-SX-MM SFP interface to a 100Base-FX interface.  You will need to swap the SFP on the 3560G with a 100Base-FX SFP (GLC-FE-100FX).
    Cisco 100-Megabit Ethernet SFP Modules  Compatibility Matrix
    <http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL632702.html>
    Hope this helps.
    Tom

  • 100 Mbps support on SFP GLC-T

    Does the GLC-T SFP installed on Cat-6500 WS-X6724-SFP module support 100 Mbps speed ?

    It depends on the hardware the SFP is installed in. Ss you have already discovered in a 3560 (or 3750) the GLC-T SFP can operate at 10, 100 or 1000Mbps. If the GLC-T was installed in a Catalyst 6500 6748-SFP or a 6724-SFP module it will only operate at 1000Mbps.
    I haven't seen a specific list showing the operating speeds of the GLC-T in different platforms. If you look at the documentation for the specific hardware you have you should see whether it supports 10/100/1000 or just 1000BaseT
    3750 details:
    http://www.cisco.com/univercd/cc/td/doc/product/lan/cat3560/12225see/scg/swint.htm#wp1028308
    HTH
    Andy

  • 1000BaseT interface SFP (GLC-T=) settings

    Can the speed be changed on the 1000BaseT GLC-T= SFP ports?
    Also, tried to change speed nonegotiate with no luck.
    Any help appreciated.
    Thanks
    Mark

    No, it cannot be changed.

  • I need a special configurations for this??? Module SFP GLC LH-SM

    I have a problem I need to connect an Administrative Seat, thus I am in the process of purchase of this I modulate GLC-LH-SM: 1000BASE-LX/LH
    this I modulate this designed to work with fiber signals monoway (SM) and multiway (MM)?
    as we have both means of transmicion could be re-usable?

    YES,
    the GLC 1000Base LX/LH module will work with both SM & MM modes.
    upto 10km with singleMode fiber and upto 550m with multiMode fiber.
    please see the following link for more info:
    http://www.cisco.com/en/US/products/hw/modules/ps5455/products_data_sheet0900aecd8033f885.html

  • Cisco SFP GLC-LH-SM unknown in show interface status

    Hi all,
    Client installed a single mode fibre run from Distribution Switch to Access switch. The distance is not even greater than 100 Metres but the client insisted since the fibre is free.
    On the Cisco Catalyst 2960X-24TS-L (Access layer not stacked) the SFP is identified, but on the Cisco Catalyst 2960X-24TS-L (Distribution switch stacked) the SFP module is "unknown".
    access_sw#
    Gi1/0/49 access_sw po notconnect 1 auto auto 1000BaseLX SFP
    dist_sw#
    Gi1/0/49 dist_sw po notconnect 1 auto auto unknown
    Distribution switch is running 150-2.EX4
    Access switch is running 150-2.EX5
    I have configured on both sides speed nonegotiate, above output is showing that the 2 are not even talking to each other since their status is still auto auto...
    Any ideas is gladly appreciated in terms of what show commands or diagnostic tests I can do for the interface just to test it?
    I have tried to test it but it is saying diagnostic monitoring is not running, how can I run that feature as well?  Is that network impacting if I did?
    Kind regards,

    Hi,
    Is there a link light on either side of the connection?
    Is the SFP on the distro switch also LX?
    If there is no link light, try crossing the strands on one side of the connection and test again.
    HTH

  • Cisco Catalyst 3750V2-24FS-S can't accept GLC-FE-100FX SFP Transceiver

    I have Cisco Catalyst 3750V2-24FS-S with OS version 12.2(55)EY, the problem it's can't accept GLC-FE-100FX SFP module, it's show
    unsupported SFP error but it' work fine with GLC-FE-100LX.
    Cisco 100-Megabit Ethernet SFP Modules Compatibility Matrix in bellow link show WS-C3750V2-24FS-S work with Transceiver Models :
    GLC-GE-100FX
    GLC-FE-100FX
    GLC-FE-100LX
    GLC-FE-100BX-D
    GLC-FE-100BX-U
    http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL632702.pdf
    Any help is appreciated

    Hi,
    I'm connectiong to 100FX SFP ports ( 1 to 24), showing error message:
    “ %PHY-4-SFP-NOT-SUPPORTED: The SFP in Fa1/0/1 in not supported”
    Thanks

  • WS-X6148-FE-SFP and transceiver

    Hi,
    what are the SFP transceivers compatible with the catalyst6500/cisco7600 module WS-X6148-FE-SFP.
    Thanks.

    Hi,
    Following are the supported SFPs on WS-X6148-FE-SFP linecard -
    GLC-FE-100FX
    GLC-FE-100LX
    GLC-FE-100BX-D
    GLC-FE-100BX-U
    GLC-FE-100EX
    GLC-FE-100ZX
    Table 3 - http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL632702.html
    -> Sushil

  • Interconnect two SG500's based on MGBBX1 or GLC-BX-D?

                       Hi,
    I want to connect two SG500 switches on 150 meters distance. Do I realy need a MGBBX1 on one end and a GLC-BX-D on the other end?
    Sounds wiered to me... Why is this?
    Regards,
    Klaas.
    http://www.cisco.com/en/US/docs/interfaces_modules/csbna/mgb/quick_start/guide/Optical_Module_QSG_en-US.pdf

    Hi,
    For the Cisco MGBBX1, use the Cisco GLC-BX-D as the
    downstream SFP. For the Cisco MFEBX1, use the Cisco GLC-FE-
    100BX-D as the downstream SFP. The Cisco MGBBX1 and the
    Cisco MFEBBX1 support upstream only
    Since you use only one strand of fiber you have a different wavelength for sending in each direction.
    One side is transmitting using the 1490 nm wavelength, and the other side is transmitting on  1310 nm wavelength (and receiving on the 1490nm).
    The MGBBX1 only supports the -U upstream version afaik. From the acccess side to the core side of the network.
    So in the core you need the other version, and there is no MGBBX1 SKU for this version.
    if at all possible for 150m you should consider Multimode with 2 threads and MGBSX1 as
    1000BASE-BX10 is capable of up to 10 km over a single strand of fiber.
    hope that helps
    jo

  • SG200 SFP Compatibility

    Hello,
    We want to connect SG200 to Catalyst 2960X via optical fibre. Now on our SG200 (SG200-50P-K9-EU) switches are using D-Link DEM-311GT SFP modules.
    We found module Cisco GLC-SX-MMD, that is compatible with Catalyst series switches, but there's no info about Small Business series. Someone has tried to run this module on Cisco SB?

    Hello,
    SG200 series support these SFP:
    http://www.cisco.com/c/en/us/products/collateral/switches/small-business-100-series-unmanaged-switches/data_sheet_c78-634369.html
    Product Ordering Number
    Description
    MFE Transceivers
    MFEBX1
    100BASE-BX-20U SFP transceiver for single-mode fiber, 1310 nm wavelength, supports up to 20 km
    MFELX1
    100BASE-LX SFP transceiver for single-mode fiber, 1310 nm wavelength, supports up to 2 km
    MFEFX1
    100BASE-FX SFP transceiver for multimode fiber, 1310 nm wavelength, supports up to 10 km
    MGE Transceivers
    MGBBX1
    1000BASE-BX-20U SFP transceiver for single-mode fiber, 1310 nm wavelength, supports up to 40 km
    MGBLH1
    1000BASE-LH SFP transceiver for single-mode fiber, 1310 nm wavelength, supports up to 40 km
    MGBLX1
    1000BASE-LX SFP transceiver for single-mode fiber, 1310 nm wavelength, supports up to 10 km
    MGBSX1
    1000BASE-SX SFP transceiver for multimode fiber, 850 nm wavelength, supports up to 550 m
    This link provides compatibility information:
    https://supportforums.cisco.com/document/140221/interconnect-cisco-sb-switch-and-catalyst-switch-sfp
    To interconnect a Small Business switch with Cisco Catalyst switch, you need to use Cisco Small Business SFP on the Small Business switches, and Cisco traditional SFP on Catalyst switches. And the SFP on both sides should follow the same IEEE standard. The mapping table is shown below.
    Cisco Small Business SFP
    Cisco traditional SFP
    GE Transceiver
    MGBSX1
    GLC-SX-MM
    SFP-GE-S
    MGBLX1
    MGBLH1
    GLC-LH-SM
    MGBBX1
    GLC-BX-D
    MGBT1
    GLC-T
    SFP-GE-T
    FE Transceiver
    MFEFX1
    GLC-FE-100FX
    GLC-GE-100FX
    MFELX1
    GLC-FE-100LX
    MFEBX1
    GLC-FE-100BX-D
    Thanks.
    Yiu Kay Lee
    Concentrix at Cisco
    .:|:.:|:. CISCO | Yiu Kay Lee | SMB Pre-Sales | [email protected] | Phone +1 (855) 354-7776

  • 100BASE-BX10 SFP

    Hi All,
    I have several Cisco 3560C setup at multiple stations. The Cisco 3560C are connected in a daisy chain between each other using 100BASE-BX10-D and 100BASE-BX10-U SFP. So, on the first Cisco 3560C (station 1), I have a U-type connecting to the second Cisco 3560C (station 2.). The second Cisco 3560C (station 2) will have a D-type and U-type SFP where the D-type connects to the previous station 1 on its U-type SFP. This setup repeats for station 3 onwards.
    It seems that these connections between the stations, I noticed that the Cisco switch registers the link at 100Mb half-duplex and I see incrementing CRCs and collisions. I am not able to hard-code the interface to 100Mb FULL as it seems that the interface configuration does not give me the option to do a 'speed 100' or 'duplex full'.
    Is this normal for these kinds of SFP?
    Below are some outputs:
    Cisco IOS Software, C3560C Software (C3560c405-UNIVERSALK9-M), Version 12.2(55)EX3, RELEASE SOFTWARE (fc2)
    Technical Support: http://www.cisco.com/techsupport
    Copyright (c) 1986-2011 by Cisco Systems, Inc.
    Compiled Wed 10-Aug-11 07:37 by prod_rel_team
    Image text-base: 0x00003000, data-base: 0x02100000
    Switch(config)#do sh int status
    Port      Name               Status       Vlan       Duplex  Speed Type
    Fa0/1                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/2                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/3                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/4                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/5                        connected    15         a-full  a-100 10/100BaseTX
    Fa0/6                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/7                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/8                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/9                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/10                       notconnect   15           auto   auto 10/100BaseTX
    Fa0/11                       connected    trunk      a-full  a-100 10/100BaseTX
    Fa0/12                       connected    trunk      a-full  a-100 10/100BaseTX
    Gi0/1                        connected    trunk      a-half  a-100 100BaseBX-10U SFP
    Gi0/2                        connected    trunk      a-half  a-100 100BaseBX-10D SFP
    Switch#sh interfaces gigabitEthernet 0/2
    GigabitEthernet0/1 is up, line protocol is up (connected)
      Hardware is Gigabit Ethernet, address is c025.5c11.928d (bia c025.5c11.928d)
      Description:
      MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec,
         reliability 254/255, txload 1/255, rxload 1/255
      Encapsulation ARPA, loopback not set
      Keepalive not set
      Half-duplex, 100Mb/s, link type is auto, media type is 100BaseBX-10D SFP
      input flow-control is off, output flow-control is unsupported
      ARP type: ARPA, ARP Timeout 04:00:00
      Last input 00:00:00, output 00:00:00, output hang never
      Last clearing of "show interface" counters never
      Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
      Queueing strategy: fifo
      Output queue: 0/40 (size/max)
      5 minute input rate 80000 bits/sec, 22 packets/sec
      5 minute output rate 16000 bits/sec, 16 packets/sec
         74931 packets input, 21611558 bytes, 0 no buffer
         Received 48734 broadcasts (39982 multicasts)
         0 runts, 0 giants, 0 throttles
         667 input errors, 667 CRC, 0 frame, 0 overrun, 0 ignored
         0 watchdog, 39982 multicast, 0 pause input
         0 input packets with dribble condition detected
         23385 packets output, 3857612 bytes, 0 underruns
         0 output errors, 564 collisions, 1 interface resets
         0 babbles, 29 late collision, 0 deferred
         0 lost carrier, 0 no carrier, 0 PAUSE output
         0 output buffer failures, 0 output buffers swapped out

    Yes scope all connections with a 900 micron 200x scope, and clean anything you can.
    GLC-FE-100BX-U
    100BASE-BX10-U
    -8
    -14
    -3
    -28.2
    GLC-FE-100BX-D
    100BASE-BX10-D
    -8
    -14
    -3
    -28.2
    If its clean, check the TX/RX power levels with a power meters.  End-to-end; bidirectional test, on both lamdas.
    Because of the CWDM going on, I'm not sure I'd trust the internal "show hard" or
    "show interfaces interface-id transceiver detail" internaly.
    Obviously this is something common/systemic since it happens betwen multiple locations.
    Is the fiber the common denominator?

  • GLC-GE-100FX vs GLC-FE-100FX Which to Use?

    What is the differance between the GLC-GE-100FX and GLC-FE-100FX modules. I thought all SFP ports on switches were Gigabit ports and thus the GE version would be needed for 100fx connectivity. Which switches would you use each SFP in? In particular I need to know which ones to use in a 2960-24PC-L switch and a 3560-8PC Switch.

    If you look closer at that compatibility matrix that Paulo and I posted the other day the FE is for 100BASE-FX SFP module for 100-MB ports and the GE is for 100BASE-FX SFP module for Gigabit Ethernet ports. Not all SFP slots are Gig.
    Here is the compatiblity matrix again.
    http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL632702.html
    For the 3560 here are the compatible SFPs
    GLC-FE-100FX
    GLC-FE-100LX
    GLC-FE-100BX-D
    GLC-FE-100BX-U
    And for the 2960, Paulo stated that all of the 100FX SFPs are compatible.

Maybe you are looking for

  • Workflow for Vendor Master

    Do we have any functionality of workflow for vendor master.

  • Problem with EXIF metadata reading

    Hi everyone I'm trying to read EXIF metadata information. Here is my code snippet: uchar* exifData; Handle exifDataHandle = filterRecord->handleProcs->newProc(100); propSuite->getPropertyProc('8BIM', propEXIFData, 0, nil, &exifDataHandle); exifData =

  • ManagedConnectionFactory not found for jndiName SquareConnector

    Im trying to access a Connector I wrote and im getting the error:           <190004> ManagedConnectionFactory not found for jndiName SquareConnector           The rar package is exactly the same as one in an ear package that works.           I have t

  • IPlanet Expired Password check

    We use an IPlanet authenticator for our LDAP. I've been tasked with finding a way to prompt the user for a new password if the password has not been changed in 90 days. I think the IPlanet server has the attribute of LastPasswordSetDate or something

  • Windows 8 Network Connection Enable/Disable

    In Windows Network Adapter Settings, a shortcut can be created to Desktop by rightclick on the icon and then dragged to Taskbar or a Toolbar that you have created - useful item in Windows 8. I enable/disable the adapter based on my need to be interne