SG Switch SNMP Port Control Problems

Hello All,
I'm trying to disable/enable ports via snmp v2 on a Cisco SG500-52P-K9-V01 switch.  The communties are setup properly and I even have successful snmpset commands which when queried display that the action was complete.  The issue is that when I disable the port via snmp the device on that port does not drop offline.  This is a PoE port with a device powered over PoE so I'd expect the port to disable but also the PoE to turn the device off - neither happens. 
Has anyone had experience with port management on this device?  I also noticed the interface IDs (for port 1 for discussion) are 1, 101, 201 etc.  I've tried setting on 1 and 101 only but the results have been the same and what were mentioned above.
Any help or suggestions would be appreciated.  I've tested on other switches and this works without any trouble.
Thanks!

I believe I've figured out the offsets.  The FastE seems to be at a 0 offset, so port 22 is is 22 and then we go to GigE and port 22 would be at index 70.
Now that I've figured this out I can't for the life of me get an snmp set to work.  I've tried enable/disable/testing and also tried basic OID set for sysName and sysDesc.  Has anyone had luck using SNMP write on these switches?  Is there a setting that I'm missing?  I've set the SNMP access mode to SNMP Admin and the View Name to DefaultSuper and my write community is set properly.  No luck...

Similar Messages

  • Homing switch causing motion control problems

    I am controlling a dome for a telescope. I have a home position switch and motion control using one of NI's motion controllers. Everything works fine except for one bug. The dome just goes around and around. I can run a Home type reference search and it works fine. But if I command a position that runs through the home switch zone the dome stops moving. If I hit the command a second time it runs right to the correct position.
    So why does the home switch stop the motion if I am not doing a reference search. Should I be using some other form of referencing?
    Thanks,
    Dave
    David A. Taylor

    Do you have the home switch also configured as a limit switch?
    What motion hardware are you using.  In addition to home limits, the ni cards often have a + limit and - limit and also a software limit, these can be configured via the api or in max.
    Paul Falkenstein
    Coleman Technologies Inc.
    CLA, CPI, AIA-Vision
    Labview 4.0- 2013, RT, Vision, FPGA

  • System Control msg "Get Configuration port has problems

    Hello !
    1) Do you know what the System control manager is doing and where I can find some information about the program?
    2) Do you know what the message " Get confirmation port has problems" means that comes up every time I start the computor since I installed the System control manager ?
    Best regards Namretto

    Comments:                      My system/Namretto
    >>
        Model:                         AMD Athlon(tm) XP 3200+
        Speed:                         2.19GHz
        Model Number:                  3200 (estimated)
        Performance Rating:            PR3177 (estimated)
        Type:                          Standard
        L2 On-board Cache:             512kB ECC Synchronous Write-Back (16-way, 64
                                       byte line size)
        Bus(es):                       ISA AGP PCI USB i2c/SMBus
        MP Support:                    No
        MP APIC:                       No
        System BIOS:                   Phoenix Technologies, LTD 6.00 PG
        Mainboard:                     MICRO-STAR INTERNATIONAL CO., LTD MS-6570
        Total Memory:                  511MB DDR-SDRAM
        Model:                         Nvidia Corp nForce2 AGP Controller
        Front Side Bus Speed:          2x 199MHz (398MHz data rate)
        Total Memory:                  512MB DDR-SDRAM
        Memory Bus Speed:              2x 199MHz (398MHz data rate)
        Monitor/Panel:                 Dell 1501FP (analog)
        Adapter:                       RADEON 9600 SERIES  
        Adapter:                       RADEON 9600 SERIES - Secondary  
        Removable Drive:               Diskettenhet
        Hard Disk:                     ST312002 6AS SCSI Disk Device
        CD-ROM/DVD:                    Memorex 40MAXX 1248AJ
        CD-ROM/DVD:                    _NEC DVD_RW ND-2500A
        1.44MB 3.5" (A:):              N/A
        Hard Disk (C:):                29.3GB (19.2GB, 65% Free) (NTFS)
        Hard Disk (D:):                82.5GB (71.3GB, 86% Free) (NTFS)
        CD-ROM/DVD (E:):               N/A
        CD-ROM/DVD (F:):               N/A
        Serial/Parallel Port(s):       2 COM / 1 LPT
        USB Controller/Hub:            Standard OpenHCD USB Host Controller
        USB Controller/Hub:            Standard OpenHCD USB Host Controller
        USB Controller/Hub:            Standard Enhanced PCI to USB Host Controller
        USB Controller/Hub:            USB-rotnav (hub)
        USB Controller/Hub:            USB-rotnav (hub)
        USB Controller/Hub:            USB-rotnav (hub)
        Keyboard:                      Standard 101/102-Key or Microsoft Natural PS/
                                       2 Keyboard
        Mouse:                         HID-compliant Cordless Mouse
        Human Interface:               Logitech Cordless USB Mouse
        Device:                        NVIDIA(R) nForce(TM) Audio Codec Interface
        Model:                         HP DeskJet 670C
        Model:                         \\HEMPC\SKRIVARE 6
        Model:                         \\HEMPC\SKRIVARE 3
        Model:                         \\HEMPC\SKRIVARE
        Model:                         \\HEMPC\PRINTER
        AC Line Status:                On-Line
        Windows System:                Microsoft Windows XP/2002 Home (Win32 x86)
                                       5.01.2600 (Service Pack 1)
        Adapter:                       NVIDIA nForce MCP Networking Controller
        Adapter:                       Realtek RTL8139/810x Family Fast Ethernet NIC

  • Quicktime Problems Behind Router Wont Switch To Port 80 http Intel Duo

    Just bought a new iMac Duo it will not stream QT behind my Linksys router. Now I know this is a bug in QT on the duo and a port or ports not being open for this new version of QT on the Duo because all other Macs I have work fine.
    Looks to be that the transport for QT will not switch to port 80 HTTP.
    If I move the iMac Duo to a DMZ zone it will stream just fine.
    Now what UDP or TCP port range do I need to open for this iMac Duo version of QT 7.0.4 to stream properly ?????
    Thank you for your help.

    Hi all,
    Here is what I did to fix the problem for now.
    Set the QT transport setup on my iMac Duo to use port 554 UDP.
    I did a port forward on my router to the iMac Duo:
    * Open port 554 for RTSP/TCP data.
    * Open ports 6970 through 6999 (inclusive) for RTP/UDP data.
    Then made the ip address on the iMac Duo static.
    Issue still existis with QT on the Duo is the transport on QT will not automatcally or manually stay on HTTP port 80.
    Indeed this will on some routers keep you from streaming video like the keynotes from Apple for example.
    So if you are having a problem this will fix it.
    Hope this helps.

  • My trackball/mouse hangs! They work,then they don't. If I switch usb ports they work for a while.

    I have a Pavilion a1657c using Windows XP.  I use a Kensington trackball and lately it has been hanging up on me. I switched to a Logitech mouse and it did the same thing. Now, I have both plugged in and if I switch usb ports one of them will work for a short period of time and then hangs. If I switch usb ports again, one of them will work for a while....I never know which one is going to work..very sporadic and it is driving me nuts. I am semi-literate with computers, but no whiz. Somebody help me of this road to nutsville..?

    Hello icnhndlu, This appears to be a USB common issue, since you mention the issue occurs on different USB ports and devices.
    This may be a hardware fault, but you might try uninstalling all the USB devices in the Control Panel, Device Manager. Then reboot the system and see if the operating system will detect new hardware and install the drivers for the new hardware.
    The drivers are provided by Microsoft within the operating system.
    Not sure this will work, but may be worth a try.
    Please click the White Kudos star on the left, to say thanks.
    Please mark Accept As Solution if it solves your problem.

  • Topic : Alesis Master Control Problem (to previous post unanswered fixed)

    Topic : Alesis Master Control Problem to the original post user: Garrud
    Me:111984cz i have an answer to ur problem.i too had the same problem with cubase 5 ,Nuendo 4 and any of Steinberg softwares with the alesis master-control studio interface. i hope u run into this to learn my fix.
    the problem is check ur midi input on your actual track.make sure it says to (master-control midi port) and not (all midi inputs).as for your device manager settings set to (master-control port) don't set your midi to all or master control port as it will interfere .now it will work perfect.this is for all who have the same problem as well.hope this helps many as i spend a lot of hours of trouble shooting.i almost thought there was something wrong with my mixer.have a great day guys!!
    Original post:
    I've installed the MasterControl driver as instructed and followed the logic set up instructions provided with the MC and all that seems to happen is the Controller acts as a midi keyboard playing different notes rather than the intended function.
    e.g if i touch one of the faders it plays a high pitched note and if i move the fader it acts like the note is being pitched, like a pitch bend function on a keyboard.
    Very strange...cannot figure out whats going on
    PLEASE HELP I'M GOING INSANE
    MacBook Pro Mac OS X (10.6.4)

    I too had the same problem and resolved it.
    However, I have had nothing but issues with the Alesis Mastercontrol since it arrived last week. I purchased mine second-hand as a replacement to a Fire-Wire / Analogue mixer made by Mackie (Onyx 1220). A fantastic amp, but not a control surface.
    I decided I wanted an all rounder, plus something I could place in-front of my iMac so I could work on the fly.
    So...
    1) Alesis Mastercontrol
    2) 1 x Rode microphone in Ch1
    3) 1 x Rode microphone in Ch2
    4) Peavey guitar in Ch3
    I use Logic Studio Pro 8.
    I finally figured out how to get the Alesis to behave and interact with Logic. So far so good!
    I then ran into a series of issues that are frustrating me.
    I cannot get the microphones to mute properly (I would also complain about the poorly position gain dials at the back of the unit for the microphones. So poor indeed that I have purchased an Art mic preamp to slap into the back (not arrived yet) and by-pass the rear controls).
    I also cannot get my semi-acoustic Peavey to record at all. I can hear it through the control desk, but it is much lower than expected and I am getting nothing when I try to record). In record mode the pair of mics record and I can't get the 3rd channel to operate, although it looks like it's functioning on the screen. I try MUTE / SOLO and selecting the correct channel, but nothing!
    All I can do is record myself playing guitar through the mics I cannot switch off.
    Strange machine! Almost wishing I'd not sold my Mackie Onyx 1220 so swiftly.

  • Intel iMac; upgraded adobe flash; bluetooth keyboard no longer pairs but magic mouse still OK. With Bluetooth switched on the screen splits into 4 areas and open windows seperate and shrink. Switch off Bluetooth and problem disappears and iMac works OK

    Intel iMac; upgraded adobe flash; bluetooth keyboard no longer pairs but magic mouse still OK. With Bluetooth switched on the screen splits into 4 areas and open windows seperate and shrink. Switch off Bluetooth and problem disappears and iMac works OK with plug-in keyboard and mouse

    Hi, Derek -
    ...the screen splits into 4 areas and open windows seperate and shrink.
    Sounds like Spaces is being activated somehow. With the wired keyboard and mouse in use, select the Exposé & Spaces control pane in System Preferences, click the choice in that pane for Spaces. See what the settings are. There are some activation settings in that pane - by default, F8 activates it.
    It could be that the bluetooth keyboard has some stuck keys and is activating Spaces; or that the activation command has somehow been reset to something that the bluetooth mouse, or bluetooth itself, is triggering.

  • User Account Control Problems with Premier Elements 7 32 bit in 64 Bit Windows 7

    I found User Account Control Problems in other forums but didn't see much in Premiere Elements, so I hope this helps others who may be having problems with 32 bit programs in a 64 bit computor. When I first got my 64 bit I didn't have problems.
    Back in February I bought a Quad Core Desktop with Windows 7 64 bit. Haven't been on the forum for 7 months since I wrote in regarding importing video with the Pyro AV Link (Premiere Elements Tips and Tricks). I was having problems importing video which started after March 28 sometime, as that was the last time I didn't have a problem importing VHS. Took me a few months off and on to find out what worked.
    I started uninstalling Windows updates and any programs I had installed back to that point in time. Checked after uninstalling each item. The capture screen would come up on a delayed basis but clicking on capture did nothing. Although no driver is required for IE1394 (so they say) I read where some people using the Legacy driver had fixed some problems, so I switched to the Legacy. Seemed to work great (for a few minutes).
    I had even uninstalled and reinstalled PE7 but no difference. Finally I noticed a shield in the PE7 Desktop icon. Thats weird. Never had that before. Just decided to show up after I had done all of the stuff I mentioned. Turns out at some point in time since I've had the computor Windows 7 decided to flag my 32 bit program as misusing the 64 bit system. User Account Control. I never bothered too much with UAC and just clicked on the yes box wen it popped up asking if I wanted this or that to take control of my computor. I tried using the minimum setting for safety reasons, and then finally turned User Account Control off. Bingo! PE7 capture works again and still working.
    While I am not recommending that people arbitrarily turn UAC off, this appeared to be my problem. I would recommed that they try turning it off before uninstallin a bunch of stuff. Having a restore point may or may not have been a fix for me. I think one of the Windows Updates caused the problem but I am not going to uninstall any more stuff at this point, I have not been back on the internet or installed any more updates in my desktop. I am going to use my laptop for internet and used the desktop for video.
    I am guessing this could be a problem for any 64 bit systems trying to use 32 bit programs. IE: XP,Vista,Windows 7 64 bit. In Vista there is also Data Execution Prevention (DEP) which you can turn on or off, supposedly to prevent misuse of memory (as I understand it), but Win7 either doesn't have it or I haven't found where it's located.
    Maybe this has been covered in the forum somewhere and I missed reading it. Hope I am not too confusing. Anyway, whatever feedback you guys have would be great.  

    John,
        Thanks for your answer, and I did check out the link you suggested. However, I have Windows 7 Home Premium as most people have I think, and the XP program was not available. I started with Vista and now have Win 7. I never could navigate around in XP anyway so am content to just leave User Account Control off.
        Interesting side note to turning UAC off is that my desktop seemed to be using more of the CPUs, where half of them were "Parked" as I wrote in also about 7 months ago when I 1st got my desktop. I am pleased to say that video processing seems to go quicker with UAC off. Have to observe things some more to confirm.
        I just thought if others were having problems after installing Windows Updates and leaving UAC off worked then they could possibly pinpoint a problem.

  • Query: Best practice SAN switch (network) access control rules?

    Dear SAN experts,
    Are there generic SAN (MDS) switch access control rules that should always be applied within the SAN environment?
    I have a specific interest in network-based access control rules/CLI-commands with respect to traffic flowing through the switch rather than switch management traffic (controls for traffic flowing to the switch).
    Presumably one would want to provide SAN switch demarcation between initiators and targets using VSAN, Zoning (and LUN Zoning for fine grained access control and defense in depth with storage device LUN masking), IP ACL, Read-Only Zone (or LUN).
    In a LAN environment controlled by a (gateway) firewall, there are (best practice) generic firewall access control rules that should be instantiated regardless of enterprise network IP range, TCP services, topology etc.
    For example, the blocking of malformed TCP flags or the blocking of inbound and outbound IP ranges outlined in RFC 3330 (and RFC 1918).
    These firewall access control rules can be deployed regardless of the IP range or TCP service traffic used within the enterprise. Of course there are firewall access control rules that should also be implemented as best practice that require specific IP addresses and ports that suit the network in which they are deployed. For example, rate limiting as a DoS preventative, may require knowledge of server IP and port number of the hosted service that is being DoS protected.
    So my question is, are there generic best practice SAN switch (network) access control rules that should also be instantiated?
    regards,
    Will.

    Hi William,
    That's a pretty wide net you're casting there, but i'll do my best to give you some insight in the matter.
    Speaking pure fibre channel, your only real way of controlling which nodes can access which other nodes is Zones.
    for zones there are a few best practices:
    * Default Zone: Don't use it. unless you're running Ficon.
    * Single Initiator zones: One host, many storage targets. Don't put 2 initiators in one zone or they'll try logging into each other which at best will give you a performance hit, at worst will bring down your systems.
    * Don't mix zoning types:  You can zone on wwn, on port, and Cisco NX-OS will give you a plethora of other options, like on device alias or LUN Zoning. Don't use different types of these in one zone.
    * Device alias zoning is definately recommended with Enhanced Zoning and Enhanced DA enabled, since it will make replacing hba's a heck of a lot less painful in your fabric.
    * LUN zoning is being deprecated, so avoid. You can achieve the same effect on any modern array by doing lun masking.
    * Read-Only exists, but again any modern array should be able to make a lun read-only.
    * QoS on Zoning: Isn't really an ACL method, more of a congestion control.
    VSANs are a way to separate your physical fabric into several logical fabrics.  There's one huge distinction here with VLANs, that is that as a rule of thumb, you should put things that you want to talk to each other in the same VSANs. There's no such concept as a broadcast domain the way it exists in Ethernet in FC, so VSANs don't serve as isolation for that. Routing on Fibre Channel (IVR or Inter-VSAN Routing) is possible, but quickly becomes a pain if you use it a lot/structurally. Keep IVR for exceptions, use VSANs for logical units of hosts and storage that belong to each other.  A good example would be to put each of 2 remote datacenters in their own VSAN, create a third VSAN for the ports on the array that provide replication between DC and use IVR to make management hosts have inband access to all arrays.
    When using IVR, maintain a manual and minimal topology. IVR tends to become very complex very fast and auto topology isn't helping this.
    Traditional IP acls (permit this proto to that dest on such a port and deny other combinations) are very rare on management interfaces, since they're usually connected to already separated segments. Same goes for Fibre Channel over IP links (that connect to ethernet interfaces in your storage switch).
    They are quite logical to use  and work just the same on an MDS as on a traditional Ethernetswitch when you want to use IP over FC (not to be confused with FC over IP). But then you'll logically use your switch as an L2/L3 device.
    I'm personally not an IP guy, but here's a quite good guide to setting up IP services in a FC fabric:
    http://www.cisco.com/en/US/partner/docs/switches/datacenter/mds9000/sw/4_1/configuration/guides/cli_4_1/ipsvc.html
    To protect your san from devices that are 'slow-draining' and can cause congestion, I highly recommend enabling slow-drain policy monitors, as described in this document:
    http://www.cisco.com/en/US/partner/docs/switches/datacenter/mds9000/sw/5_0/configuration/guides/int/nxos/intf.html#wp1743661
    That's a very brief summary of the most important access-control-related Best Practices that come to mind.  If any of this isn't clear to you or you require more detail, let me know. HTH!

  • Dot1x port-control auto protocol down (ACS5.3)

    Hello everyone! 
    I urgently need your help please. 
    I would like to configure the ports of a switch for 802.1x. 
    when I type the command: Dot1x harbor auto-control on the interface, the protocol is down and users are disconnected wiring. 
    Can someone help me please? it is really urgent.
    thank you in advance

    hello
    thank you for your answer.
    bellow is the configuration  that i've configured on the switchs:
    configure terminal
      aaa new-model
      aaa authentication dot1x default group radius
      interface fastethernet0/1
      dot1x port-control auto
      end
     radius-server host x.x.x.x auth-port 1612 key xxxx
    but the command : dot1x port-control auto , cause protocol dows but the port status is UP.
    I did not understand the function of this command:"Dot1x harbor auto-control" 
    could you tell me a little more?
    thank you in advance.

  • Pulseaudio rapidly automatically switches output ports

    I have been having this issue for quite a long time now. When louder sound plays I hear choppy output. When that happens, I can see that in pavucontrol -> Output devices -> "Built-in Audio Analog Stereo" -> "Port:" selection rapidly switches between Headphones and Analog output. When output is loud, it selects Analog output and when it's more silent, it switches to Headphones. Since happens very fast and because "Analog output" and "Headphones" have different output levels, I get choppy sound. So how do I make pulseaudio not switch between ports? I am thankful that pulseaudio cares about my ears, but I'd prefer if it didn't.
    One solution is to set both "Headphones" and "Analog Stereo" to same level, but I don't think it's an elegant solution. Another way to stop this is to set output less than ~80%, but this isn't acceptable either.
    I use headphones btw, and default output device Port is "Headphones" in pavucontrol.
    P.S. Issue also described here.
    Last edited by axper (2013-03-02 13:05:46)

    OK I got this problem back, it happens with rear port as well.
    In pavucontrol -> Configuration tab I have 2 controllers:
    "High Definition Audio Controller", which I guess is my nvidia card output which I don't use anyways, and It doesn't do anything when select it
    "Built-in Audio", which I guess is motherboard's ports, and it has the following profiles:
    Analog Stereo Duplex
    Analog Stereo Output
    Analog Stereo Input
    Off
    With these profiles happens exactly what I have described in original post.
    Digital Stereo (IEC958) Output + Analog Stereo Input
    Digital Stereo (IEC958) Output
    With these profiles, I still get exact same cracking audio, however in "Output Devices" tab a new "Built-in Audio Digital Stereo (IEC958)" appears, below normal "Built-in Audio Analog Stereo", AND the "Port" Selection does NOT change.
    chancho wrote:instead of muting a port, can you disable the port in the pavucontrol->configuration->profile ?
    You mean set "Profile" to Off? I tried that, same result.
    eeg wrote:Under pavucontrol->configuration->profile, instead of selecting Analog Stereo Output, use Analog Surround 4.0 Output.
    I have no Surround 4.0 Ouptput in the menu.
    Any direction what to try next would be appreciated.
    Last edited by axper (2013-07-01 20:16:49)

  • Port-channel problem with WiSM

    Has anybody met following similar problem:
    I put WiSM into slot 3(also tried slot 6) of 6506(sup720-3B, s72033-adventerprisek9_wan-mz.122-33.SXH.bin), using following command to setup the port-channel:
    interface Port-channel1
    switchport
    switchport trunk encapsulation dot1q
    switchport trunk native vlan 5
    switchport trunk allowed vlan 1-1000
    switchport mode trunk
    int range g3/1-4
    switchport
    switchport trunk encapsulation dot1q
    switchport trunk native vlan 5
    switchport trunk allowed vlan 1-1000
    switchport mode trunk
    channel-group 1 mode on
    I can use "session slot 3 pro 1" to login to the WiSM, but can't ping WiSM's management IP address from 6506, then I find the port-channel has problem, only G3/1 is up and included in the channel, G3/2-4 are up but line protocol is down, then I found from the log that: "AESUT: %EC-SP-5-CANNOT_BUNDLE2: Gi3/2 is not compatible with Gi3/1 and will be suspended (qos-card type unavailable for Gi3/2 or Gi3/1)". It says those GE port are not compatible for qos-card type, but I checked the configuration, all GE using the same configuration. Don't know why, maybe a bug? Appreciate for any feedback

    I have the same problem, but it has something to do with QoS. When you disable "mls qos" on the switch, the port-channel will function normal again.
    It doesn't help when you configure "mls qos trust dscp" on the port-channel!!!!!

  • My switch Linksys srw224g4 has problem and I need someone help

    Hello,
    My switch Linksys srw224g4 has problem that it keeps rebooting continuously and cannot bootup successfuly. Can someone tell me how to fix this problem? Firmware version is 1.2.2b , boot version is 1.0.2
    Here is console capture:
    ==================
    ------ Performing the Power-On Self Test (POST) ------
    UART Channel Loopback Test........................PASS
    Testing the System SDRAM..........................PASS
    Boot1 Checksum Test...............................PASS
    Boot2 Checksum Test...............................PASS
    Flash Image Validation Test.......................PASS
    BOOT Software Version 1.0.2 Built  17-Aug-2006  14:55:46
    Linksys SmartSwitch based on 88E6218 with ARM946E-S.
    32MByte SDRAM. I-Cache 8 KB. D-Cache 8 KB. Cache Enabled.
    Autoboot in 2 seconds - press RETURN or Esc. to abort and enter prom.
    Preparing to decompress...
     100%
    Decompressing SW from flash
     100%
    OK
    Running from RAM...
    *** Running  SW  Ver. 1.2.2b  Date  20-Mar-2007  Time  11:44:49 ***
    HW version is 00.03.00
    Base Mac address is: 00:1d:7e:74:b6:14
    Dram size is  : 32M bytes
    Dram first block size is  : 16969K bytes
    Dram first PTR is  : 0xF6D840
    Flash size is: 8M
    01-Jan-2000 01:01:02 %CDB-I-LOADCONFIG: Loading startup configuration.
    LZMA: Decompressing file failed!
    HOSTG_rscode_file_load: could not load file
    Device configuration:
    Slot 1 - SRW24F4G HW Rev.  0.2
    Tapi Version: v1.3.3.1
    Core Version: v1.3.3.1
    01-Jan-2000 01:01:09 %SYSLOG-F-OSFATAL:
    L FATAL ERROR: ROOT: ABORT DATA exception 
    ***** FATAL ERROR ***** 
    SW Version  :  1.2.2.16
    Version Date:  20-Mar-2007
    Version Time:  11:44:49
    Instruction            0x121fc0
    Exception vector       0x10
    Program state register 0x20000013
    *****************  SYSTEM RESET  *****************
    ------ Performing the Power-On Self Test (POST) ------
    UART Channel Loopback Test........................PASS
    Testing the System SDRAM..........................PASS
    Boot1 Checksum Test...............................PASS
    Boot2 Checksum Test...............................PASS
    Flash Image Validation Test.......................PASS
    BOOT Software Version 1.0.2 Built  17-Aug-2006  14:55:46
    Linksys SmartSwitch based on 88E6218 with ARM946E-S.
    32MByte SDRAM. I-Cache 8 KB. D-Cache 8 KB. Cache Enabled.
    Autoboot in 2 seconds - press RETURN or Esc. to abort and enter prom.
    Preparing to decompress...
     100%
    Decompressing SW from flash
     100%
    OK
    Running from RAM...
    *** Running  SW  Ver. 1.2.2b  Date  20-Mar-2007  Time  11:44:49 ***
    HW version is 00.03.00
    Base Mac address is: 00:1d:7e:74:b6:14
    Dram size is  : 32M bytes
    Dram first block size is  : 16969K bytes
    Dram first PTR is  : 0xF6D840
    Flash size is: 8M
    01-Jan-2000 01:01:02 %CDB-I-LOADCONFIG: Loading startup configuration.
    LZMA: Decompressing file failed!
    HOSTG_rscode_file_load: could not load file
    DelScr fatal Error: Invalid Variant type01-Jan-2000 01:01:03 %SYSLOG-F-OSFATAL: DelScr fatal Error
    ***** FATAL ERROR *****
    Reporting Task: ROOT.
    Software Version: 1.2.2b (date  20-Mar-2007 time  11:44:49)
    *****************  SYSTEM RESET  *****************
    Thanks,
    Tien

    Hi,
    Please follow the steps in this link to reload the image:
    http://www.cisco.com/en/US/products/ps9967/products_qanda_item09186a0080a36371.shtml
    And this is the link to download boot code 1.00.86:
    http://ip.gliebetronics.com:800/firmware/Linksys%20SRW2024/Firmware/
    Hope this help.

  • How can I encrypt my data links between switch uplink ports ? I'm unable to use "cts Manual" command in C3560X switch.suggest me

    How can I encrypt my data uplinks between switch trunk ports ? I'm unable to use "cts Manual" command in C3560X switch.suggest me as I want to encrypt my switch-to-switch link with Cisco TrustSec.

    Hi 
    Login to switch & go to interface..
    There you can give tags.. (ISL & DONT1Q)
    Command switch-port mode trunk
    Switch-port trunk encapsulation ssl or dot1Q

  • I keep getting error 3004 when i try restoring and updateing my iphone 4 to iOS 7 i did everything 1. flushed dns 2. edited hosts 3. updated itunes and downloaded new one 4. switched usb ports 5. disabled antivirus 6. enabled ports 80 and 443 7. disabled

    I keep getting error 3004 when i try restoring and updateing my iphone 4 to iOS 7 i did everything 1. flushed dns 2. edited hosts 3. updated itunes and downloaded new one 4. switched usb ports 5. disabled antivirus 6. enabled ports 80 and 443 7. disabled firewall 8. even tryed putting mobile in DFU mode to restore it not of this worked so please help me

    please replyyy i'm stuck on this like whole week

Maybe you are looking for

  • ITunes refuses to read music on second internal HDD

    Hello! I realize this topic has been asked to death, we need some form of sticky topic! After a bit of searching, I haven't turned up anything I haven't tried. Here goes: -I just got my old 400mhz AGP G4 up and running - 768 MB RAM, OS 10.4.8, a new

  • How to create view object for a predefined Oracle view

    Trying to create an entity object with no success,,, I have an Oracle view(complex query in PL/SQL) that I need to encapsulate as a View Object then represent a column from this view as a '' | | linkcolumn | | '' then get a reference of the requestPa

  • How to delimit leading zero in vendor number in OO ABAP ALV without using conversion routine

    Hi, How to delimit leading zero in OO ABAP ALV without using conversion routine, because I have many fields like vendor, customer, material number etc.. How to address this leading zero. I appreciate your quick response. Regards, Nalini S.

  • Importing ear file in Worshop 10

    hi, i exported an web application ear file in workshop in weblogic 10. Now when i try to import the same file in the workshop and want to run it, I don't know what file to run on the server. I am new to Weblogic, and just noticed that the .jsp file t

  • PP CC 2014. All screens are gone. PPro seems to be running invisibly.

    I very briefly tried to watch my project on my Apple TV. It has worked many times in the past, but not today. Immediately after the Apple TV started, all the Premiere Pro windows were gone from my computer display. I shut down the Apple TV and the co