Shipping Tab in PO on / off .no error message.

Hi,
      we have situation where user creates STO and shipping tab is On / off. sometime it displays sometime does't..we have observed its only happening      one particular purchasing group mentioned in header level of STO .no error message shows up.this case is only with one user.we have check the roles with user who can create STO with Shipping tab but no luck. any suggestion is much appreciated.
Thanks,

As we know this field doesn't depend on purchase group in standard.
Field selection is depend on document type or transaction variant.
Here, your field selection is differ against purchase group.
I am quite sure you have some development in your program SAPLMEGUI.
Debug the t-code ME21N using this particular purchase group with the help of an ABAP.
You will find the reason.

Similar Messages

  • When starting Firefox 4 I get an error message. After clicking OK it nevertheless runs. How can I get rid off the error message.

    When starting up Firefox 4 I get an error message. After clicking OK it nevertheless runs. How can I get rid off the error message?
    The error message is: what happened: Type Error: Components. classes ['@mozilla.org/extensions/manager;1'] is undefined.
    It appears all the time already from the beginning after installing Firefox 4.

    Thanks a lot. The Ask toolbar created this problem. Another problem is: When searching on the web via Google, normally it is possible to type a few letters and then look what appears and then click on the wanted word(s). A number of word(s) ineed do appear, however it is not possible to select any of them as ws possible as mentioned in olders versions.

  • My toouch smart iq506 is giving off the error message biohd-2

    my touch smart iq506  is giving off the error message biohd-2

    There is quite a discussion about the error message, its meaning, troubleshooting steps, and the results from last year on this forum. Please see:
    http://h30434.www3.hp.com/t5/Desktop-Operating-systems-and/Error-Code-BIOHD-2/td-p/299253
    It will offer some information and solutions for you.
    GeorgeFN
    GeorgeFN
    I work on behalf of HP.

  • My emac safari launches with no search screen and when i open a new tab it shuts down wit an error message???

    Hi, and thanks in advance. I have an emac thats working fine except for safari. Click safari the top bar comes up but no page and when i open a new tab it shuts down with a error and message saying it unexpectedly quit and send to apple or relaunch.

    safari that i am running is 4.3.1

  • I used to use IE2 tab in FF to watch video in some sites e.g BBC iplayer. However with recent versions of FF when I switch IE tab for vid I get an error message

    The IE tab 2 add on functions correctly in so far as it brings up the page in an IE tab and does so perfectly except for any video windows.
    The error message received is in the video window:
    "There was a problem initialising the player" and "script access is denied in your browser"
    Is there any way to change an FF or IE setting to correct this,
    Thanks,

    Yes, thanks John99, I was aware of that and I am also aware that FF works well with most if not all video providers most of the time. I use IE tab 2 in FF for the odd occasion when i have problems in the FF tab.
    I can also use the tab option of "Open in Ext. App" which also works with BBC iplayer and the other video providers where the "switch renderering engine" does not.
    I suppose I may be being a bit of a perfectionist but i think that an application should work properly- it works with YouTube for example, therefore it should work with the BBC- perhaps it is down to the BBC iplayer team. Thanks again anyway.

  • Random videos on youtube just don't work and give off an error message. I've reinstalled and reset firefox and still nothing.

    Lately some random videos that I try to watch just don't even try to load and instantly give off the "There was an error during playback" message I open it in IE and it works fine no problem. I've been trying to fix it on my own from reinstalling firefox or resetting it to trying a new profile. I wasn't getting this problem until I had to reinstall firefox to get myth-weavers.com to work. Ever since I freshly reinstalled firefox some videos have not work.
    -Not blocked by isp
    -Videos are often from the same uploader.
    -seems like every 4 or 5 videos is down.
    -I went to try and update my plugins in stuff and this was found http://imgur.com/bGWnrSf
    -not sure what to do about above.
    -my java is up to date.

    Hi Fayko, a couple of other users are reporting this problem, too.
    Did you notice any difference in Safe Mode? To spell that out a bit more: Firefox's Safe Mode is a standard diagnostic tool to deactivate extensions and some advanced features of Firefox. More info: [[Troubleshoot Firefox issues using Safe Mode]].
    You can restart Firefox in Safe Mode using either:
    * "3-bar" menu button > "?" button > Restart with Add-ons Disabled
    * Help menu > Restart with Add-ons Disabled
    Not all add-ons are disabled: Flash and other plugins still run
    After Firefox shuts down, a small dialog should appear. Click "Start in Safe Mode" (''not'' Reset).
    Any difference?
    Regarding your Java plugins, the "Deployment" one might not be updateable but the regular Java SE is. You can use the link on the plugin check page or [http://www.java.com/en/download/testjava.jsp]. But Youtube doesn't use the Java plugin, so that would just be for sites that do.

  • Every time Firefox runs the 1st tab is "about:sessionrestore" with an error message when its shutdown. How can I clear it?

    2nd tab is my default and all works well.

    The Reset Firefox feature can fix many issues by restoring Firefox to its factory default state while saving your essential information.
    Note: ''This will cause you to lose any Extensions, Open websites, and some Preferences.''
    To Reset Firefox do the following:
    #Go to Firefox > Help > Troubleshooting Information.
    #Click the "Reset Firefox" button.
    #Firefox will close and reset. After Firefox is done, it will show a window with the information that is imported. Click Finish.
    #Firefox will open with all factory defaults applied.
    Further information can be found in the [[Reset Firefox – easily fix most problems]] article.
    Did this fix your problems? Please report back to us!

  • STO - Shipping Tab

    Hi,
    while creating STO with ME21n transaction, working well with out any errors in DEV & TESTING server. But in PROD Server, shipping tab is not displaying and giving error "Not possible to determine shipping data for material".
    Please guide and advise.
    Regards
    Vijay.

    Hi Vijay,
    Since STO is working fine in Dev and Testing and i assume all your Development request having custamization for STO being transported to PRD then there should not be custamization problem...
    pls check the master data...
    i guess you want this for STO UB type...pls check
    1)Material master is maintained in distribution channel that you have defined for STO and is maintained with shipping data like loading grp
    2) Internal customer number of the receiving plant which you assign in custamization has been created in PRD since this is master data while testing you must have created in DEV and Test Server using XD01
    Let us know whether this resolves or not
    Regards
    Jagdish

  • Turn off list view error messages

    HI,
    I have a custom default view in a list. Sometimes it shows "Unable to display view..." error message when loading the view, but the view can be shown by refreshing the page. My question is, is there any way to turn off the error message? I want
    to hide this message from users.

    what is the exact error message?
    how long does it take before it prompts the error message? Initial hit may be taking longer and times out. Next refresh does the trick as information gets rendered from the cache.
    ensure the list has total number of items within the "Threshold Limit" set on the Web Application in Central Admin
    Naveed.DG MCITP, MCTS -SharePoint 2010 Administrator "Vote As Helpful" If it helps!!

  • Error message after clicked the SRM "Full Functionality" tab

    Hi, SRM gurus,
    After I logon to SRM and clicked on the "Full Functionality" tab, I immediately got the following error message.
    Short Text of the Message: Object type SCH is not supported
    URL: http://augustus.corp.bcm.tmc.edu:1080/sap/bc/webdynpro/sapsrm/wda_l_fpm_oif/
    Path: /sap/bc/webdynpro/sapsrm/wda_l_fpm_oif/
    Message ID: BS 
    Message Type: E
    Message No.: 018
    Message Variable 1: SCH
    Message Variable 2: 
    Message Variable 3: 
    Message Variable 4: 
    Error Code: 560
    Error Text: ERROR_MESSAGE_STATE
    Runtime Error: Object type SCH is not supported
    ABAP Call Stack: Method:  CREATE_SC_INT of program /SAPSRM/CL_PDO_FACTORY_SC_ADV=CP
    Method:  CREATE_NEW_INSTANCE of program /SAPSRM/CL_PDO_FACTORY_SC_ADV=CP
    Method:  CONSTRUCTOR of program /SAPSRM/CL_CH_WD_BOM_SC=======CP 
    I had no problem at other tabs like "Order Status", "Advance Search".
    Where should I look to resolve the issue?
    Thanks in advance!
    Best regards,
    Fisher Li

    ...SRM and clicked on the "Full Functionality" tab...
    I have never seen this tab. Is it a custom tab? In any case, by looking at your error message, I suspect somewhere in your iView definition, the object type is mistaken.  Instead of "SCH", it most likely should be "SHC", which is the default process type for shopping cart.

  • HR - Supress Error messages at end of PNP Logical dB ABAP

    It appears from the code for logical dB PNP that you can turn off the error messages that automatically print at the end of the program, but I don't see how to do it.  Here's the SAP code in include DBPNPI01:
    FORM end-processing.
      CHECK sw_supress_write EQ no.
    Can anyone tell me how to 'change' sw_supress_write?

    Try this code:
    DATA:
      BEGIN OF t_empty OCCURS 50,
            pernr LIKE pernr-pernr,
      END   OF t_empty.
    DATA:
      temp1 TYPE i,
      temp2 TYPE i,
      temp3 TYPE i.
    NODES: pernr.
    START-OF-SELECTION.
      PERFORM pnp_skipped_pernr(sapdbpnp)
        TABLES t_empty
        USING 'Y'
        CHANGING temp1 temp2 temp3.
    GET pernr.
    * Do something here.
    *FORM pnp_skipped_pernr
    *         TABLES   locked_pernr_tab     LIKE locked[]        "out
    *         USING    supress_reject_info  LIKE sw_supress_write"in
    *         CHANGING auth_skipped_count   LIKE auth-skip-count "out
    *                  locked_skipped_count LIKE locked_pernr_count"out
    *                  locked_occurs_param  LIKE locked_ocp.     "out
    *  locked_pernr_tab[]   = locked[].
    *  sw_supress_write     = supress_reject_info.
    *  auth_skipped_count   = auth-skip-count.
    *  locked_skipped_count = locked_pernr_count.
    *  locked_occurs_param  = locked_ocp.
    *ENDFORM.                               "pnp_skipped_pern
    Let us know how it goes.

  • How to enable the screen after triggering the error message

    Hi All,
    we have a tcode IW31, in that one field(WBS element -PROID) is not mandatory. so we have written the following code to make it mandatory in a user exit EXIT_SAPLCOIH_010.It's triggering the error message, but it is going into disable mode. Please sugget me how to enable the screen after getting the error message triggering.
    if not caufvd_imp-proid is initial.
      select single * from t350 into wa_t350
              where  auart    = caufvd_imp-auart
                and  imord    = 'X'.
      if sy-subrc is initial.
        pspel = caufvd_imp-proid.
      else.
        call function 'CONVERSION_EXIT_ABPSP_OUTPUT'
             exporting
                  input  = caufvd_imp-proid
             importing
                  output = l_posid.
        concatenate text-t10 l_posid text-t11
                    into l_textline1 separated by space.
        message i208(00) with l_textline1.
      endif.
    else.
      message e208(00) with 'Please maintain WBS element in Location Tab'.
    endif.
    Thanks

    Hi,
    Instead of error message use status message like
    message s208(00) with 'Please maintain WBS element in Location Tab'.
    Leave to screen sy-synnr.
    This will allow to move to the screen and have in enable mode.
    WIth Regards,
    Dwaraka.S
    Edited by: Dwarakanath Sankarayogi on Feb 13, 2009 7:46 AM

  • Purchase Order - Error messages

    Dear All,
    We are creating Purchase order , due to one of our processes we get a Error and we are not able to save the PO.
    We understand the error but we canot maintain some source list due to our processes.
    Is there a way like a USER enhancement to run off the error message in this special case or say convert the error message to
    WARNING instead of showing as Error.
    Thanks in advance,
    O

    Can you please post the error description and the error message number.
    When you get the error, double click in the bar that appears at the bottom of the screen and get the error message details.
    Regards,
    Pedro

  • Required Error Message for To Unrestricted Use field in QA11

    Hi QM Experts,
    kindly,suggest me for:
    In QA11 i have made mandatory to To unrestricted Use field in Inspection Lot stock tab but it just pass an error message in only Inspection Lot Stock tab.I want to pass this same error message in Characteristics Tab also.so,what should i do for this?
    Thanks & Regards,
    Vivek Bhojak

    Hi Vivek,
    As far as I understand, if you have made quantity field for unrestricted stock mandatory in QA11 "Inspection Lot Stock" tab, then you can't post UD in "Characteristic" tab without entering any quantity there in the previous screen. Is it happening in the expected way or it is not working? If not working - then please check with your ABAP team!!
    I am not very sure about the merit of the enhancement you are trying to achieve here. Reason being, for example, the inspection lot stock Quantity is 100 PC, and you put 10 PC in unrestricted Qty, then what do you expect for the rest of 90 PC? As UD may post 10 PC unrestricted and the remaining 90 PC may be in Q-Stock!!. I think, this is a challenge you may be facing technically & you should consider a new logic - "Unless at least one quantity field in 'to be posted' section for "Inspection lot Stock" tab is populated, the user can't apply UD code. Still this may not be a full proof logic as during UD, you still need to take care of the remaining stock quantity too.
    I have already answered your other questions in the below thread - https://scn.sap.com/thread/3717344. Please refer it for further details, and close duplicate threads.
    Thanks,
    Arijit

  • NetUI Error Message

    I get the following message for every field (with a netui tag) on my form. Although
    the operation succeeds and the information is saved in the formbean, I still get
    this message every time. Does anyone know what it means?
    NETUI ERROR: Unable to update expression "{pageFlow.employmentInfo[0].otherEmployer[0].status}"
    with the value [].
    The typical cause is that the object represented by the expression is not available
    or is the wrong type for updating.
    INFO - NETUI ERROR: Unable to update expression "{pageFlow.employmentInfo[0].otherEmployer[0].status}"
    with the value [].
    The typical cause is that the object represented by the expression is not available
    or is the wrong type for updating.
    INFO - Exception evaluating expression "pageFlow["employmentInfo"][0]["currentEmployer"]"
    with contexts: [actionForm, session, request, response]
    Throwable: knex.scripting.javascript.EvaluatorException: The undefined value has
    no properties.
    Stack Trace:
    knex.scripting.javascript.EvaluatorException: The undefined value has no properties.
    at knex.scripting.javascript.DefaultErrorReporter.runtimeError(D efaultErrorReporter.java:61)
    at knex.scripting.javascript.Context.reportRuntimeError(Context.j ava:699)
    at knex.scripting.javascript.Context.reportRuntimeError(Context.j ava:738)
    at knex.scripting.javascript.Context.reportRuntimeError0(Context .java:708)
    at knex.scripting.javascript.Undefined.reportError(Undefined.jav a:149)
    at knex.scripting.javascript.Undefined.get(Undefined.java:78)
    at knex.scripting.javascript.ScriptRuntime.getElem(ScriptRuntim e.java:1128)
    at knex.scripting.javascript.Interpreter.interpret(Interpreter.java:1 907)
    at knex.scripting.javascript.InterpretedScript.call(InterpretedScri pt.java:72)
    at knex.scripting.javascript.InterpretedScript.exec(InterpretedScr ipt.java:63)
    at knex.scripting.javascript.Context.evaluateReader(Context.java :991)
    at knex.scripting.javascript.Context.evaluateString(Context.java: 930)
    at com.bea.wlw.netui.script.xscript.XScriptEvaluator.execScript( XScriptEvaluator.java:547)
    Thanks!

    You can find the reason for this error in the "Re: NETUI Error" message
    posted at 8/18/2003.
    To get rid off this error message, simply set the "redirect = true" for that
    forward action.
    Bob
    "Ed Barberis" <[email protected]> wrote in message
    news:[email protected]...
    >
    I get the following message for every field (with a netui tag) on my form.Although
    the operation succeeds and the information is saved in the formbean, Istill get
    this message every time. Does anyone know what it means?
    NETUI ERROR: Unable to update expression"{pageFlow.employmentInfo[0].otherEmployer[0].status}"
    with the value [].
    The typical cause is that the object represented by the expression is notavailable
    or is the wrong type for updating.
    INFO - NETUI ERROR: Unable to update expression"{pageFlow.employmentInfo[0].otherEmployer[0].status}"
    with the value [].
    The typical cause is that the object represented by the expression is notavailable
    or is the wrong type for updating.
    INFO - Exception evaluating expression"pageFlow["employmentInfo"][0]["currentEmployer"]"
    with contexts: [actionForm, session, request, response]
    Throwable: knex.scripting.javascript.EvaluatorException: The undefinedvalue has
    no properties.
    Stack Trace:
    knex.scripting.javascript.EvaluatorException: The undefined value has noproperties.
    >
    at knex.scripting.javascript.DefaultErrorReporter.runtimeError(DefaultErrorReporter.java:61)
    >
    at knex.scripting.javascript.Context.reportRuntimeError(Context.j ava:699)
    at knex.scripting.javascript.Context.reportRuntimeError(Context.j ava:738)
    at knex.scripting.javascript.Context.reportRuntimeError0(Context.java:708)
    at knex.scripting.javascript.Undefined.reportError(Undefined.jav a:149)
    at knex.scripting.javascript.Undefined.get(Undefined.java:78)
    at knex.scripting.javascript.ScriptRuntime.getElem(ScriptRuntime.java:1128)
    at knex.scripting.javascript.Interpreter.interpret(Interpreter.java:1 907)
    at knex.scripting.javascript.InterpretedScript.call(InterpretedScript.java:72)
    >
    at knex.scripting.javascript.InterpretedScript.exec(InterpretedScript.java:63)
    >
    at knex.scripting.javascript.Context.evaluateReader(Context.java :991)
    at knex.scripting.javascript.Context.evaluateString(Context.java: 930)
    at com.bea.wlw.netui.script.xscript.XScriptEvaluator.execScript(XScriptEvaluator.java:547)
    >
    Thanks!

Maybe you are looking for