Siebel chart server configuration

Hi Experts,
After installing chart server on siebel servers, we configure the parameters DSChartServer and DSDChartImageFormat under ServerDataSrc profile.  Is it possible to have multiple chart servers installed on different siebel servers on the same enterprise and have them configured under ServerDataSrc profile parameters?  We need this clarity to check if we can setup high availability for chart servers or not.  Incase one chart server is down then will other chart server be able to pick up the load and proceed further?
Thanks,
Diwakar

Hi,
  I have installed Siebel 8.1.1.10 binary on linux machine.
Database is 11.2.0.3
Oracle Client is 11.1.0.
grantuser.sql runned also.
I have sourced cfgenv.sh fine before starting wizard for gateway server .
I have not configured gateway server yet. Starting the first step as Configuring gateway Name Server. Then i select Next, then selected port 2320 as default one. Then Next to provide response file.I have left it blank as its nit mandatory. After next step, I am getting Error
Siebel gateway Server Configuration failed.When I am checking the log files in gateway.log i am getting this details.
2021 2013-12-19 12:50:04 2013-12-19 12:50:04 +0400 00000004 001 003f 0001 09 siebel 3974 -143738496 /d01/siebel/8.1.1.0.0/ses/gtwysrvr/log/siebel.log 8.1.1.10 [23021] ENU
NameServerLayerLog Error 1 0000000252b20f86:0 2013-12-19 12:50:04 Unable to connect to the gateway server.
GenericLog GenericError 1 000000 0252b20f86:0 2013-12-19 12:50:04 NSC - ErrCode 5009  SysErr 0
GenericLog GenericError 1 0000000252b20f86:0 2013-12-19 12:50:04 (srvredit2.cpp (302) err=5009 sys=1) SBL-GEN-05009: Unable to connect to the gateway server.
I have not created Gateway and ita asking Gateway server not started.
All the Server and database are in one machine only.
Please help
Regards,
Anirudh

Similar Messages

  • Odbc failure for Siebel database server configuration

    Hi all,
    I am installing siebel 7.8.2 in my system. I am using oracle 10g...
    I have installed siebel gateway name server .
    After siebel server installation and configuration,
    I was checking for ODBC connectivity as given in manual but i am getting the following error:
    Cannot validate username/password combination.
    HY000: [DATA direct] [ODBC Oracle Driver][Oracle] Ora-12538: TNS: no such protocol adapter
    further details are:
    I have installed Oracle 10g application server(both oracleasinfra and oracleasmidtier)... my oracle_home is oracleasinfra... and my running listener is also infrastructure listener... and my siebel database where i have run grantusr.sql script is also database which is in oracleasinfra...
    Please help me out?

    Hi Manuel Dias,
    I believe those information would be easily found out through SQL Server 2005 references or guides.  There may not have any special needs for B1 database.
    Thanks,
    Gordon

  • Siebel 8.1.1.11 • Error in Siebel Server Configuration

    Problem Description
    Hi,
    I'm trying to make the Siebel Server Configuration for a new Development Environment.
    After completing the Siebel Configuration Wizard I am having the following error:
    2021 2014-05-28 12:40:21 2014-05-28 12:40:21 -0300 00000004 001 003f 0001 09 srvrmgr 3672 2404 D:\Siebel\8.1.1.11.0\ses\siebsrvr\log\srvrmgr.log 8.1.1.11 [23030] ENU
    GenericLog GenericError 1 0000000553860e58:0 2014-05-28 12:40:21 (sccobjs.cpp (964) err=2555932 sys=0) SBL-SCM-00028: Key not found
    GenericLog GenericError 1 0000000553860e58:0 2014-05-28 12:40:21 (samisc.cpp (284) err=2555932 sys=0) SBL-SCM-00028: Key not found
    GenericLog GenericError 1 0000000553860e58:0 2014-05-28 12:40:21 (sasess.cpp (399) err=2555932 sys=0) SBL-SCM-00028: Key not found
    Please can guide me to solve this problem
    Kind regards,
    Christian
    Error Codes
    SBL-SCM-00028
    Problem Category/Subcategory
    Installation (installation of FPs, QFs, PSs, Product Certification & Supported Platforms)/Siebel Server
    Uploaded Files
    File: srvrmgr.log;srvrcfg.log

    Siebel Name Server Backing File
    8.1.1.11 [23030] ENU
    1.2
    BAkAAAAAAAA=            
      Persistence=partial
      Type=empty
    [/enterprises]
      Type=empty
    [/enterprises/FUSION_SES]
      Type=empty
    [/enterprises/FUSION_SES/servers]
      Type=empty
    [/enterprises/FUSION_SES/servers/SIEBELSRVR]
      Type=empty
    [/enterprises/FUSION_SES/servers/SIEBELSRVR/parameters]
      Type=empty
    [/enterprises/FUSION_SES/servers/SIEBELSRVR/parameters/Host]
      Type=string
      Value="fusion_server"
      Length=26
    [/enterprises/FUSION_SES/servers/SIEBELSRVR/parameters/ServerDesc]
      Type=string
      Value="Siebel Server Profile SIEBELSRVR FUSION"
      Length=78
    [/enterprises/FUSION_SES/servers/SIEBELSRVR/parameters/Lang]
      Type=string
      Value="ENU"
      Length=6
    [/enterprises/FUSION_SES/servers/SIEBELSRVR/attributes]
      Type=empty
    [/enterprises/FUSION_SES/servers/SIEBELSRVR/attributes/SyncStartTime]
      Type=string
      Value="000100"
      Length=12
    [/enterprises/FUSION_SES/servers/SIEBELSRVR/attributes/Primarylang]
      Type=string
      Value="ENU"
      Length=6
    [/enterprises/FUSION_SES/servers/SIEBELSRVR/attributes/SyncPlannedCompletion]
      Type=string
      Value="000100"
      Length=12
    [/enterprises/FUSION_SES/servers/SIEBELSRVR/attributes/SyncEndTime]
      Type=string
      Value="000100"
      Length=12
    [/gateways]
      Type=empty
    [/gateways/default]
      Type=empty
    [/gateways/default/version]
      Type=empty
    [/gateways/default/version/VersionString]
      Type=string
      Value="8.1.1.11 SIA [23030] ESN"
      Length=48
    [/gateways/default/definition]
      Type=empty
    [/gateways/default/definition/name]
      Persistence=full
      Type=string
      Value="default"
      Length=14
    [/gateways/default/definition/full name]
      Persistence=full
      Type=string
      Value="Siebel Gateway"
      Length=28
    [/gateways/default/definition/description]
      Persistence=full
      Type=string
      Value="Siebel Gateway Server"
      Length=42
    [/gateways/default/definition/enable state]
      Persistence=full
      Type=string
      Value="enabled"
      Length=14
    [/gateways/default/definition/object id]
      Persistence=full
      Type=integer
      Value=0
    [/gateways/default/attributes]
      Type=empty
    [/gateways/default/attributes/UseDefault]
      Type=string
      Value="SBA_82"
      Length=12
    [/gateways/default/attributes/CreateDefault]
      Type=string
      Value="SBA_82"
      Length=12

  • Siebel Server Configuration failed

    I am able to configure Siebel gateway name server, siebele enterprise server,
    but when i configure Siebel Server it shows execution failed...
    Do i need ti install any language pack Siebel Server configuration? May be that is reason why i am not able to configure Siebel Server... If you think some another problem let me know...
    Also i am configuring Siebel 8.0 for my oracleAS adapter 10.1.2.0.2.. is it fine?
    Please help me out...
    Your reply will be very much appreciated...
    Thanx in advance...

    On another note, I thought Siebel 8.0 needs to use a specific version of Oracle AS for Linux..
    For all others the minimum is AS 10.1.3... You might have problems on your SWSE install.

  • Siebel Gateway Name Server Configuration Wizard returns "Execution failed"

    Hi,
    I am installing Siebel 8.1.1.1 on Linux platform and now having problem while trying to configure Siebel Gateway Name Server.
    Steps done:
    1) DB instance prepared
    2) Created Siebel installation image
    3) Installed Siebel server and configured Gateway name server (the wizard started automatically as part of the installation). Skip configuration of Enterprise and SWSE Logical profile
    4) Ran DB Configuration Wizard for the primary language - successfully. Import repository-add language - successfully.
    5) Trying to Wizard "Configure Enterprise" - failed with "Execution failed"
    Here I thought that probably Gateway Nameserver was not configured and decided to remove the Gateway and create it from scratch.
    Unfortunately this time the Gateway configuration failed. Also with message"Execution failed"
    Here are the errors I got in the log files sw_cfg_util*.log
    <EF><BB><BF>2021 2012-01-25 16:14:56 2012-01-25 16:14:56 +0200 00000002 001 003f 0001 09 sw_cfg_util 17234 -1215752512 /OraSSO_tstcol/siebapp/server/siebsrvr/log/sw_cfg_util.log 8.1.1 [21111] ENU
    GenericLog GenericError 1 000000024f204352:0 2012-01-25 16:14:56 (svrconfig.cpp (2465) err=3023557 sys=0) SBL-CSO-08901: The required arguments are not specified.
    GenericLog GenericError 1 000000034f20432e:0 2012-01-25 16:14:56 Executing step: CreateGateway
    GenericLog GenericError 1 000000034f20432e:0 2012-01-25 16:14:58 Step CreateGateway: failed to run program %%SiebelRoot%%%%OSDirSeparator%%bin%%OSDirSeparator%%srvrcfg with cmdline -u nouser -p nopassword -r %%SiebelRoot%% -g %%SiebelRoot%%%%OSDirSeparator%%sys%%OSDirSeparator%%siebns.dat::NSFILE: -r %%SiebelRoot%% -a gateway -l %%PrimaryLanguage%% -i %%SiebelRoot%%%%OSDirSeparator%%admin%%OSDirSeparator%%gtwydefs.dat
    GenericLog GenericError 1 000000034f20432e:0 2012-01-25 16:14:58 Failed during Execution, err: 5500044
    Does anybody know what is the reason?
    Searching in Metalink and Google were fruitless..
    Thank you in advance.

    Just in case anybody bumps in this thread:
    The problem in my case was solved according with Oracle Note "Delete and create the "Siebel Server" via Configuration Wizard on Linux, it failed. [ID 880562.1]"
    Applies to:
    +Siebel CRM - Version: 8.1.1 SIA [21111] and later   [Release: V8 and later ]+
    Linux x86
    Symptoms
    Delete the "Siebel Server" once and then create a new "Siebel Server" via Siebel Server Configuration Wizard on Linux, it failed with message "Execution Failed".
    The error on sw_cfg_util_xx.log is as follows,
    GenericLog GenericError 1 0000ce524a3a1bd2:0 2009-06-19 10:18:33 Executing step: AddSrvrRegistryEntry
    GenericLog GenericError 1 0000ce524a3a1bd2:0 2009-06-19 10:18:35 Step AddSrvrRegistryEntry: failed to run program %%SiebelRoot%%%%OSDirSeparator%%bin%%OSDirSeparator%%siebctl with cmdline -r %%SiebelRoot%% -q -S siebsrvr -i "%%SiebelEnterprise%%:%%SiebelServer%%" -a -g "-g %%SiebelGateway%% -e %%SiebelEnterprise%% -s %%SiebelServer%% -u %%Username%%" -e %%Password%%
    GenericLog GenericError 1 0000ce524a3a1bd2:0 2009-06-19 10:18:35 Failed during Execution, err: 5500044
    Reproduce steps:
    - confirm that siebel server was created before, and is stopping.
    - create sh env and enter the following command to remove the Siebel Server.
    +$ cd $(SiebelServerRoot)+
    +$ . ./cfgenv.sh+
    +$ cd $(SiebelServerRoot)/bin+
    +$ ./ssincfgw+
    - select "3 - Remove Existing Configuration".
    - complete the configuration wizard.
    - enter the following command to create the Siebel Server.
    +$ cd $(SiebelServerRoot)+
    +$ . ./cfgenv.sh+
    +$ cd $(SiebelServerRoot)/bin+
    +$ ./ssincfgw+
    - select "1 - Create New Configuration".
    - continue inputs to finish and execute the configration.
    +==> you'll find "Execution Failed".+
    Cause
    AddSrvrRegistryEntry section shown in the log is the command for registering the Windows Service, and it is no need to execute on Linux env. However, it is executed and it failied.
    Solution
    You can do either of follows,
    +(1) Uninstall and Install the Siebel Server again.+
    +(2) The section to execute the Windows registeration command is specified on $(SiebelServerRoot)/admin/common.scm, line 2475-2477.+
    +[Step]+
    Name = AddSrvrRegistryEntry
    Type = RunProg %%SiebelRoot%%%%OSDirSeparator%%bin%%OSDirSeparator%%siebctl ' -r %%SiebelRoot%% -q -S siebsrvr -i "%%SiebelEnterprise%%:%%SiebelServer%%" -a -g "-g %%SiebelGateway%% -e %%SiebelEnterprise%% -s %%SiebelServer%% -u %%Username%%" -e %%Password%% '
    So, delete the AddSrvrRegistryEntry section from common.scm, and execute Configuration Wizard again.
    Edited by: mmango on Jan 31, 2012 12:21 AM

  • Sub:when trying to open "adminisration  server  configuration"

    Hi
    all,
    when i am trying to open component definitions in admin server configuration, I am getting following error.
    An error has occurred creating business component 'Enterprise Service Definitions' used by business object 'Server Admin'. Please ask your systems administrator to check your application configuration.(SBL-DAT-00222)
    please let me know the solution.
    thanks
    sudhakar

    Hi,
    Maybe you would have already done this activity.
    If not just check if the responsibility "Siebel Administrator" is mapped to the user id using which you were getting such errors.
    Regards,
    Sambit

  • Minumum hardware requirement for Siebel Document server?

    what is the minimum hardware requirement for Siebel document server?

    To install the Document Server, perform the following steps:
    Obtain the required hardware.
    Install the Siebel Server.
    Install third-party applications.
    After installing the Siebel Server, you may have to follow some of the steps described in Configuring the Document Server. The Document Server is a component of Siebel eDocuments, which can be installed during installation of the Siebel Server. Consult with your system administrator to verify that the Document Server has been installed and configured according to the requirements listed in the following sections.
    Hardware Requirements
    The Document Server is supported on the Windows 2000 platform. To maintain stability and performance, the Document Server must run on a dedicated host machine. The Siebel Server on this machine should host one instance of the Siebel eDocuments component group. No other components should be running other than required system components.
    To support more users, you can run additional instances of the Siebel eDocuments component group on additional dedicated host machines.
    Installing the Siebel Server
    Install the Siebel Server on the dedicated host machine of the Document Server. For more information about installing the Siebel Server, see Siebel Server Installation Guide for Microsoft Windows.
    During installation, you will have the option to enable component groups. Select the Siebel eDocuments component group. Do not enable any other component groups.
    This step can also be performed after installation is complete, as described in the section Enabling the Component Group.
    Installing Third-Party Applications
    You must install Microsoft Word.
    To install Microsoft Office
    Log on to the server machine using the same user account that the Siebel Server NT service uses. This user account must belong to the Administrators group.
    NOTE: The install must use the same account to be used by the NT Service. The installer configures COM security settings so that the installing user account will have the correct permissions to access and launch the application. If the install uses an account other than the Siebel Server NT service account, errors may occur when the Document Server tries to launch the application.
    Install Microsoft Office using a Typical, or complete, installation. Verify that your version of Microsoft Office will install the Web Authoring Tools (HTML) component with the Typical installation. If it does not, you will need to use the Custom installation option, and install all of the typical components as well as the Web Authoring Tools (HTML) component.
    Start the applications that will be used by the Document Server. This forces the applications to register themselves.
    Close the applications.
    Regards,
    Joseph Arul Dass

  • Siebel Charts gets generated but does not display in the Web client

    Siebel Chart is getting generated in NetChart4.6\Server\root\projects\Siebel.chart folder. However does not display on the Web client
    There is either no error displayed on the front end...
    Also note that Charts is installed on Windows environment and Siebel Server is installed on Linux Server

    Dear User,
    Thanks for using Oracle communities.
    Does this happens in dedicated client as well?
    We would need to have traffic captured when you are actually executing actions. The tools like fiddler etc will help here to track the traffic.
    I would suggest you open SR with MOS since it will need some analysis on network trace like fiddler. You can refer this thread in SR as well, so that once issue gets resolved thread will get updated with solution which will benefit others.
    Best Regards,
    Chetan

  • Job/Component running on a different siebel app server

    Applicaiton team run a job (Communications Outbound Manager) and it is on queue. When I checked it is running on different server (requested server). It is not the one currently running and configured on the server.
    What configuration should i change to fix this. Im still new to siebel and need some guidance.
    Appreciate anyone's help.

    You can check the Component for that job is enabled on which server, in Administration - Server Configuration --> Component Groups --> Components --> Component Group Assignments. Once you submit the job (without fill up the Requested Server) Siebel will automatically assigned the job to any available server with that component enabled.
    You can also defined which server to run the job by filling the Requested Server but better make sure that the component is enabled in the server you set on the Requested Server.

  • WIndows 7 64-bit system printing to a Windows 2000 server configured as a print server

    Is there any way to configure a new Windows 7 64-bit computer to use a Windows 2000 server configured as a print server ?
    The printer that I would like to connect to is an HP 4240n LaserJet. I appears that there is only a 64-bit Universal Print Driver available. The server currently uses HP 32-bit PCL5e or PCL6 drivers for all other connected computers. Connection is through a Hewlett-Packard Network Port, using DLC/LLC transport for the embedded 4240n print server.  
    Installing  the HP 64-bit UPD to the WIndows 7 64-bit system, and then attempting to redirect the local port to the Win2k network print server has not worked.
    Thanks for any advice.

    Hi:
    See if this works...
    Run msconfig.
    In the System Configuration screen, Boot tab, Advanced Options, if there is a check mark in the box next to Maximum memory. Remove that checkmark and save your changes.
    Reboot and hopefully Windows recognises all the Ram ( minus the reserved ) after restarting.
    Please give that a try, and post back and let us know if that frees up some system memory for you.
    Paul

  • Printer Server configuration for APEX 3.1.2 in 10g XE

    I have APEX3.1.2 installed in 10g XE and I am going thorough the OTN tutorial "[Oracle Application Express 3.0-- Building a Functional Application"|http://www.oracle.com/technology/obe/apex/obe30/apexdev30.htm#l7] in the section "Editing Application Objects".
    When I click "Print Attribute" of a page region, it displayed "{color:#ff0000}Report printing is currently not available, there is no print server configured{color}".
    Can you tell me what this means and how to resolve it. All I have is APEX3.1.2 installed in 10gXE.
    I have searched this forum and it seems that I have to install/configure a printer server?
    Thanks!
    Kevin

    Dan,
    I have the same problem as Kevin.
    Your answer to his question can be very helpful. But if I follow the link you provide, I cant find the step 5.2.
    Step 5.1 is clear. But what are the tasks of step 5.2?
    I hope that you can tell me this.
    Thank you.
    Carlos

  • Service Manager Data Warehouse Install - Analysis Server Configuration For OLAP Cubes Fail

    Hello everyone,
    I have an issue with my installation of the Data Warehouse for System Center Service Manager 2012 SP1.
    My install environment is the following:
    Windows Server 2012 – System Center Service Manager (Successfully Installed) - Virtual
    Windows Server 2012 – System Center Data Warehouse (Pending) - Virtual
    Windows Server 2012 – MS SQL Server 2012 – Physical, Clustered 1<sup>st</sup> of Four Servers
    The SQL Server is a clustered installation with named instances, specifically for SharePoint and Service Manager. Each instance has its own IP address and dynamic ports are turned off. I’m installing using the domain administrator account and I also chose
    to run the installer as administrator. The domain admin has sysadmin rights to the service manager server and instance I’m trying to install on. However, the account does not have sysadmin rights to some of the other instances.
    The install is smooth up until it needs to connect to the Analysis server database. I have tried connecting to the analysis servers on other SQL servers on site and all were successful. The only difference between the older SQL servers, the SQL 2012 development
    server and the SQL 2012 Production server I’m trying to install to is that the that the domain admin account doesn’t have sysadmin access on all the databases on the new production server. The SQL server is being installed and configured by a contractor so
    if you all have troubleshooting suggestions, I’ll need to coordinate with the contractor.
    Starting with the screen below, I began searching for help online. There seems to be no one else with this issue or it is not documented properly. I opened a ticket with MS, called the contractor and troubleshot with him, troubleshot as far as I could on
    my own and I’m still at a loss as to what is preventing the installer from connecting specifically to the analysis server.
    I first thought the installer was at issue or that the data warehouse sever was at issue. But all signs are pointing at the SQL server. The installer is able to connect to all the other SQL servers – including other 2012 servers (same versions) – so it can’t
    be the installer. I’m pretty sure the SQL server is going to be at issue.
    After looking at this error, I opened the resource monitor and clicked the dropdown to see if it was trying to connect to the correct server and it was. I then connected to the old and new test and development servers successfully. Then connected to the
    SQL 2008 R2 production cluster successfully. I then compared the two servers. The only difference other than the version numbers is that the admin account doesn’t have sysadmin rights on all the SQL 2012 database servers. But the database servers are not the
    problem. The analysis servers are.
    I then checked the event logs and they are empty as far as this issue is concerned. Actually, there are no errors on the SQL 2012 production box and the Data Warehouse box. I then checked the log that the installer creates during every step of the installation
    and this is what is created when the dropdown is clicked for the analysis server configuration screen. The log file location is:
    “C:\Users\admin\AppData\Local\Temp\2\SCSMSetupWizard01.txt”
    In the file is the following text.
    01:03:34:Attempting connection to SQL Server 2012 management scope on SCSMSQL2012
    01:03:34:Using SQL Server 2012 management scope on SCSMSQL2012
    01:03:36:Collecting SQL instances on server SCSMSQL2012
    01:03:36:Attempting connection to SQL Server 2012 management scope on SCSMSQL2012.johnsonbrothers.com
    01:03:36:Using SQL Server 2012 management scope on SCSMSQL2012.johnsonbrothers.com
    01:03:38:Found SQL Instance: SCSMSQL2012\PWGSQL2012
    01:03:38:Found SQL Instance: SCSMSQL2012\SCSMSQL2012
    01:03:39:Error:GetSqlInstanceList(), Exception Type: Microsoft.AnalysisServices.ConnectionException, Exception Message: A connection cannot be made. Ensure that the server is running.
    01:03:39:StackTrace:   at Microsoft.AnalysisServices.XmlaClient.GetTcpClient(ConnectionInfo connectionInfo)
       at Microsoft.AnalysisServices.XmlaClient.OpenTcpConnection(ConnectionInfo connectionInfo)
       at Microsoft.AnalysisServices.XmlaClient.OpenConnection(ConnectionInfo connectionInfo, Boolean& isSessionTokenNeeded)
       at Microsoft.AnalysisServices.XmlaClient.Connect(ConnectionInfo connectionInfo, Boolean beginSession)
       at Microsoft.AnalysisServices.Server.Connect(String connectionString, String sessionId, ObjectExpansion expansionType)
       at Microsoft.SystemCenter.Essentials.SetupFramework.HelperClasses.SetupValidationHelpers.GetASVersion(StringBuilder sqlInstanceServiceName)
       at Microsoft.SystemCenter.Essentials.SetupFramework.HelperClasses.SetupValidationHelpers.GetSqlInstanceList(String sqlServerName, Int32 serviceType)
    I’m now investigating the issue according to this output, and decided to ask you all if you’ve run into this issue and found a resolution.

    I am running into same issue . But I don't anything in the instances section related to portipv6 . I do see in the listener section , I tried to remove it . But it comes up again . Please help
    <ConfigurationSettings>
    <Security>
    <RequireClientAuthentication>0</RequireClientAuthentication>
    <SecurityPackageList/>
    </Security>
    <Network>
    <Listener>
    <RequestSizeThreshold>4095</RequestSizeThreshold>
    <MaxAllowedRequestSize>0</MaxAllowedRequestSize>
    <ServerSendTimeout>60000</ServerSendTimeout>
    <ServerReceiveTimeout>60000</ServerReceiveTimeout>
    <IPV4Support>2</IPV4Support>
    <IPV6Support>2</IPV6Support>
    </Listener>
    <TCP>
    <MaxPendingSendCount>12</MaxPendingSendCount>
    <MaxPendingReceiveCount>4</MaxPendingReceiveCount>
    <MinPendingReceiveCount>2</MinPendingReceiveCount>
    <MaxCompletedReceiveCount>9</MaxCompletedReceiveCount>
    <ScatterReceiveMultiplier>5</ScatterReceiveMultiplier>
    <MaxPendingAcceptExCount>10</MaxPendingAcceptExCount>
    <MinPendingAcceptExCount>2</MinPendingAcceptExCount>
    <InitialConnectTimeout>10</InitialConnectTimeout>
    <SocketOptions>
    <SendBufferSize>0</SendBufferSize>
    <ReceiveBufferSize>0</ReceiveBufferSize>
    <DisableNonblockingMode>1</DisableNonblockingMode>
    <EnableNagleAlgorithm>0</EnableNagleAlgorithm>
    <EnableLingerOnClose>0</EnableLingerOnClose>
    <LingerTimeout>0</LingerTimeout>
    </SocketOptions>
    </TCP>
    <Requests>
    <EnableBinaryXML>0</EnableBinaryXML>
    <EnableCompression>0</EnableCompression>
    </Requests>
    <Responses>
    <EnableBinaryXML>1</EnableBinaryXML>
    <EnableCompression>1</EnableCompression>
    <CompressionLevel>9</CompressionLevel>
    </Responses>
    <ListenOnlyOnLocalConnections>0</ListenOnlyOnLocalConnections>
    </Network>
    <Log>
    <File>msmdredir.log</File>
    <FileBufferSize>0</FileBufferSize>
    <MessageLogs>Console;System</MessageLogs>
    <Exception>
    <CreateAndSendCrashReports>0</CreateAndSendCrashReports>
    <CrashReportsFolder/>
    <SQLDumperFlagsOn>0x0</SQLDumperFlagsOn>
    <SQLDumperFlagsOff>0x0</SQLDumperFlagsOff>
    <MiniDumpFlagsOn>0x0</MiniDumpFlagsOn>
    <MiniDumpFlagsOff>0x0</MiniDumpFlagsOff>
    <MinidumpErrorList>0xC1000000, 0xC1000001, 0xC100000C, 0xC1000016, 0xC1360054, 0xC1360055</MinidumpErrorList>
    <ExceptionHandlingMode>0</ExceptionHandlingMode>
    <MaxExceptions>500</MaxExceptions>
    <MaxDuplicateDumps>1</MaxDuplicateDumps>
    </Exception>
    </Log>
    <Memory>
    <HandleIA64AlignmentFaults>0</HandleIA64AlignmentFaults>
    <PreAllocate>0</PreAllocate>
    <VertiPaqPagingPolicy>0</VertiPaqPagingPolicy>
    <PagePoolRestrictNumaNode>0</PagePoolRestrictNumaNode>
    </Memory>
    <Instances/>
    <VertiPaq>
    <DefaultSegmentRowCount>0</DefaultSegmentRowCount>
    <ProcessingTimeboxSecPerMRow>-1</ProcessingTimeboxSecPerMRow>
    <SEQueryRegistry>
    <Size>0</Size>
    <MinKCycles>0</MinKCycles>
    <MinCyclesPerRow>0</MinCyclesPerRow>
    <MaxArbShpSize>0</MaxArbShpSize>
    </SEQueryRegistry>
    </VertiPaq>
    </ConfigurationSettings>

  • OIM 11g Server Configuration Wizard Error - Cannot Connect to Oracle DB

    I appreciate any and all suggestions or thoughts on how to best continue troubleshooting this error that I am describing below.
    I am attempting to install Oracle Identity and Access Management Suite 11g on a Windows 7 machine…in following the installation guides I have successfully installed the following Oracle Components
    - Oracle Database 11.2.0.1.0
    - Created Schemas using RCU 11.1.1.3.3
    - Oracle WebLogic Server 10.3.3.0
    - Oracle SOA 11.1.1.2.0
    - Oracle SOA 11.1.1.3.0 (Patch Set)
    - Oracle IAM SUITE 11.1.1.3.0
    Following the above installations, I created a new WebLogic Domain and as the next step am running the OIM Configuration Wizard to configure the OIM Server, however I am unable to setup a connection to the Oracle DB via the OIM Configuration Wizard. I am getting an error message when attempting to setup the connection to the Oracle Database using the OIM 11g Server Configuration Wizard:
    ERROR:*
    INST:6102 Unable to connect to the database with the given credentials.
    *+[DETAILS] Check the values. Make sure the Database is up and running and connect string, user name, and password are correct.+*
    INST:6102 Unable to connect to the database with the given credentials.
    *+[DETAILS] Check the values. Make sure the Database is up and running and connect string, user name, and password are correct.+*
    When installing the Oracle Database 11gR2 I used the following install configuration:
    Oracle base: C:\MyApps\Oracle
    Software location: C:\MyApps\Oracle\DB_HOME\11.2.0\dbhome_1
    Database file location: C:\MyApps\Oracle\DB_HOME\oradata
    Database Edition: Personal Edition (3.27 GB)
    Character Set: Unicode (AL32UTF8)
    Global database name: orcl.dev.com
    Administrative Password: Password1
    Confirm Password: Password1
    When creating my Schemas using RCU 11.1.1.3.3 I used the following Database Connection Details
    DB TYPE: Oracle Database
    HOST NAME: localhost
    PORT: 1521
    SERVICE NAME: orcl.dev.com
    USERNAME: sys
    PASSWORD: Password1
    ROLE: SYSDBA
    I used a Prefix of “DEV” when creating the schemas so Schema Owners DEV_OIM and DEV_MDS where created. Also, I configured to use the same password for all Schemas: “Password1″. So the password for DEV_OIM and DEV_MDS should be the same, “Password1″.
    REPRODUCING THE ERROR
    To reproduce the error, when I launch the Oracle Identity Management 11g Configuration Wizard I am first brought to the “Welcome” Screen. I click the [Next>] button.
    Next, I am on the “Components to Configure” screen where I select OIM Server and OIM Design Console and click the [Next>] button. (NOTE I have also tested by simply selecting only the OIM Server)
    Next, I am on the “Database” screen where I enter the connection information
    Connection String: localhost:1521:orcl.dev.com
    (NOTE I have also tested using localhost:1521:orcl)
    OIM Schema User Name: DEV_OIM
    OIM Schema Password: Password1
    MDS Schema User Name: DEV_MDS
    MDS Schema Password: Password1
    When I click the [Next>] button after entering the Database Connection details I encounter the following two errors (1 error for each logon DEV_OIM and DEV_MDS)
    INST:6102 Unable to connect to the database with the given credentials.
    INST:6102 Unable to connect to the database with the given credentials.
    TROUBLESHOOTING
    NOTE: I can successfully start the Oracle DB Services and connect via the Enterprise Console, SQL Plus, and JDBCTest Java Client…I just cannot get past this connection error in the OIM Server Configuration Wizard.
    JDBCTest.java TEST CLIENT
    NOTE: THIS IS THE JAVA TEST CLIENT THAT I AM USING TO TEST DATABASE CONNECTIVITY THRU A SPECIFIED JDBC URL AND DRIVER THAT WORKS SUCCESSFULLY.*
    import java.sql.Connection;
    import java.sql.DatabaseMetaData;
    import java.sql.DriverManager;
    import java.sql.ResultSet;
    public class JDBCTest {
    public static void main(String[] args) throws Exception {
    String url = "jdbc:oracle:thin:@localhost:1521:orcl";
    String driver = "oracle.jdbc.OracleDriver";
    String user = "DEV_OIM";
    String password = "Password1";
    try {
    Class.forName(driver);
    Connection conn = DriverManager.getConnection(url, user, password);
    // Get the MetaData
    DatabaseMetaData metaData = conn.getMetaData();
    // Get driver information
    System.out.println("");
    System.out.println("#########################################");
    System.out.println("# ***DRIVER INFORMATION***");
    System.out.println("#");
    System.out.println("# Driver Name = " + metaData.getDriverName());
    System.out.println("# Driver Version = " + metaData.getDriverVersion());
    System.out.println("#");
    System.out.println("#########################################");
    System.out.println("");
    System.out.println("");
    // Get database information
    System.out.println("#########################################");
    System.out.println("# ***DATABASE INFORMATION***");
    System.out.println("#");
    System.out.println("# Database Product Name = " + metaData.getDatabaseProductName());
    System.out.println("# Database Product Version = " + metaData.getDatabaseProductVersion());
    System.out.println("#");
    System.out.println("#########################################");
    System.out.println("");
    System.out.println("");
    // Get schema information
    ResultSet schemas = metaData.getSchemas();
    System.out.println("#########################################");
    System.out.println("# ***SCHEMA INFORMATION***");
    System.out.println("#");
    System.out.println("# Schemas:");
    while (schemas.next()) {
    System.out.println("# " + schemas.getString(1));
    System.out.println("#########################################");
    System.out.println("");
    System.out.println("");
    // Get table information
    System.out.println("Tables");
    ResultSet tables = metaData.getTables("", "", "", null);
    while (tables.next()) {
    System.out.println(tables.getString(3));
    conn.close();
    } catch (Exception ex) {
    ex.printStackTrace();
    *"lsnrctl status" COMMAND TEST SUCCESSFUL*
    When the Listener Service is on I get the following output using lsnrctl status command
    C:\> lsnrctl status
    LSNRCTL for 32-bit Windows: Version 11.2.0.1.0 - Production on 21-SEP-2010 15:59:43
    Copyright (c) 1991, 2010 Oracle. All rights reserved.
    STATUS of the LISTENER
    Alias LISTENER
    Version TNSLSNR for 32-bit Windows:Version 11.2.0.1.0 - Production
    Start Date 21-SEP-2010 14:43:57
    Uptime 0 days 1 hr. 15 min. 46 sec
    Trace Level off
    Security ON: Local OS Authentication
    SNMP OFF
    Listener Parameter File C:\MyApps\Oracle\DB_HOME\11.2.0\dbhome_1\NETWORK\ADMIN\listener.ora
    Listener Log File c:\myapps\oracle\diag\tnslsnr\\listener\alert\log.xml
    Listening Endpoints Summary…
    (DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)(HOST=127.0.0.1)(PORT=1521)))
    Services Summary…
    Service “CLRExtProc” has 1 instance(s).
    Instance “CLRExtProc”, status UNKNOWN, has 1 handler(s) for this service…
    Service “orcl.dev.com” has 1 instance(s).
    Instance “orcl”, status READY, has 1 handler(s) for this service….
    Service “orclXDB.dev.com” has 1 instance(s).
    Instance “orcl” status READY, has 1 handler(s) for this service…
    The command completed successfully

    Whenever installing oracle databases, i install the software only first. Then i setup the listener. Then i create a database instance using the dbca tool. This way all the information is added to the pre-existing listener configurations rather than trying to create the listener afterwards. Also, during the dbca database creation, i supply a full service name such as orcl.hostname and use the service name in future configurations where it asked. This usually solves any issues of the listener or database not being found correctly.
    -Kevin

  • URL file-access is disabled in the server configuration

    My hosting company has made a server config change and my xslt pages have stopped working with the following error.
    It says url file access is disabled but my phpinfo() still shows allow_url_fopen = on
    What else might be the problem?
    Warning: require_once() [
    function.require-once]: URL file-access is disabled in the server configuration in
    /homepages/0/xxx/htdocs/xxxx/inc/horoscope_xml.php on line
    3
    Warning: require_once(
    http://www.xxxx.co.uk/includes/MM_XSLTransform/MM_XSLTransform.class.php) [
    function.require-once]: failed to open stream: no suitable wrapper could be found in
    /homepages/0/xxxx/htdocs/xxxxx/inc/horoscope_xml.php on line
    3
    Fatal error: require_once() [
    function.require]: Failed opening required 'http://www.xxxxx.co.uk/includes/MM_XSLTransform/MM_XSLTransform.class.php' (include_path='.:/usr/lib/php5') in
    /homepages/0/xxxx/htdocs/xxxxx/inc/horoscope_xml.php on line
    3

    bikeman01 wrote:
    I don't understand your use of the word 'class' in your reply - I am using php not asp.net.
    The name of the file that you are trying to access is MM_XSLTransform.class.php. It is a PHP class created by Dreamweaver for the XSL Transformation server behavior.
    The servers php is 5.2.11, as it has been for sometime, so I know that it previously worked with allow_url_fopen = on and allow_url_include = off
    Judging from the error message, you are trying to include the file using a URL, rather than a file path:
    Fatal error: require_once() [
    function.require]: Failed opening required 'http://www.xxxxx.co.uk/includes/MM_XSLTransform/MM_XSLTransform.class.php' (include_path='.:/usr/lib/php5') in
    /homepages/0/xxxx/htdocs/xxxxx/inc/horoscope_xml.php on line
    3
    Change the URL to a file path:
    require_once('/homepages/0/xxxx/htdocs/includes/MM_XSLTransform/MM_XSLTransform.class.php');
    Is it possible for phpinfo() to show allow_url_fopen = on yet be actually off on the server?
    No.
    [Edited to correct name of server behavior]

  • NWDI for the 04s preview fails with 'SLD name-server configuration error'

    After the installation, everything seems to work fine except that when I go to CMS, the links on the top seems to be hardcoded to point to http://pwdf3102:50100/dtr, even in the Domain Data. When I tried to change it to my local server, it keeps complaining about "Unexpected error; inform your system administrator: <Localization failed: ResourceBundle='com.sap.cms.util.exception.CMSExceptionMessages', ID='SLD name-server configuration error', Arguments: []> : Can't find resource for bundle java.util.PropertyResourceBundle, key SLD name-server configuration error"
    Any suggestions on how to work around this? Thanks.

    Brian,
    Try to import the model file first by going to SLD->Administration->Import CIM Model. If the problem sticks, then try to remove the systems. The preview version has lots of pre-exist system name in the technical system, which you can find giving errors since they're not reachable. So you can remove them from SLD (Home->Technical Systems) if they are preventing you from procceeding.
    You need to go to http://server:port/dtr/system-tools/administration/NameServerConfiguration to update the name server as well.
    Hope this helps...
    Message was edited by: Yujian Yan

Maybe you are looking for

  • Problem in sending .doc file as an attachment.!

    Hi SDN, I am using FM 'SO_NEW_DOCUMENT_ATT_SEND_API1' to send a .doc file as an attachment i am filling the the table contents_hex with my internal table containing the data in hex format but the attachment coming to the SAP office inbox is not showi

  • Material type for equipment

    hi gurus I am creating equipments for that which material type i have to choose raw material or production resource tool or any other thanks vinay

  • ITunes 7.0.2 for Windows Me Millenium Edition

    PLEASE HELP!!!!!!!!!!!!!!!!!!!!!!!!! I just got my new iPod nano today and am having trouble downloading the iTunes that is compatible with my iPod (Second Generation iPod nano). After I assume I have successfully downloaded it, and after trying to o

  • Bug in CR-200 Car App?

    My workplace is located in Cambridge, UK. However, the weather portion of the CR-200 Car App insists that I'm located in Cambridge, ON, Canada. Curiously, the Weather & Calendar app for the DT-910 stand gets it right. I suspect that the Car App is fi

  • Importing Qucktime (Mov) problem in Adobe Premiere Pro CS6

    Hello, I'm haveing a problem importing Quick time files into Adobe Premiere CS6. Whenever I try and import a quicktime mov Premiere becomes unresponsive and crashes does anyone know what the problem might be and how to rectify this issue? I'm useing