Hi XI Gurus,
I have a question regarding the 5th type of Technical Systems, Process Integration. Is it automatically generated once XI is restarted? In Note 764176, it's telling me to remove the PI technical systems. How can I recreate them? Will they be generated automatically or will we input them manually? Thanks!

Hi,
Ideally, you need to have 2 Technical System entries for your PI system and 6 entries for Technical System Type 'Exchange Infrastructure'.
the first category (i.e 2 systems) suppose to get deployed automatically using RZ70 (ABAP) and SLD Data Supplier (java).
And the 2nd catergory (i.e 6 entries) suppose to also get deployed automatically but in case, If you do not find them all here is the workaround to get them
1. If XI Integration Directory  or XI Integration Repository not found then, Please start these tools from default tools page (http://<hostname>:<http port>/dir) upon starting these 2 components you will see them added in SLD
2. If Adapter Engine not found then, logon NWA, stop & start XPI Service: AF Core & XPI facade: Adapter Framework (Navigation - Configuration Management->Infrastructure->Java System Properties); this should help you get Adapter Engine
3. The other 3 entries, Domain, Integration Server and RWB should come and usually comes always with automatic installation.
4. If you still do see after following above instructions, i suggest delete all of them both Technical specific & Exchange Infrastracture" related entries from SLD and then re-deploy RZ70, push 'Collect and Send data' option from 'SLD Data Supplier'  from NWA.
ofcourse, you can always follow the instructions provided in the note that you were refering.
Regards
Sekhar

Similar Messages

  • Technical system for integration server

    hi all
    what are the steps involved in creating a technical system for integration server?what is the role of RZ70 in creating technical system for integration server?
    regards
    bhasker.

    Hi
    Technical systems should be registered by calling transaction RZ70 in technical system. Activate the profile & excute the job.
    Make sure that you have provided correct SLD Host name & Gateway (Either central or local on XI).
    Once you execute this function a default background job will be scheduled which will run after every 12 Hrs.
    Cheers
    Rakesh

  • SLD Technical system data in ABAP table?

    Hi All,
    Can some one guide me ABAP table name where I can see all the SLD Technical system entries?
    Or can read SLD Technical system entries via some BAPI/RFC.
    Regards

    Check LCR_GET_BS_DETAILS. In se24 check for Cl_SLD* , you will get some classes which will help you get the information.
    What are the Technical system data you are looking for ?
    In program SXMS_PF_GET_OWN_IS_NAME_MC , go through the subroutine get_sld_content.

  • SLD - Technical System Type Exchange Infrastructure

    Hi experts,
    does anybody know how these Entries in the SLD appear?
    Technical System Type: Exchange Infrastructure
    Adapter Engine
    Adapter Framework
    Domain
    Integration Directory
    Integration Repository
    Integration Server
    RWB
    Runtime Management Server
    are they generated automatically? at which time? whats the trigger for them to appear?
    Or are they inserted manually?
    Thanks!
    Chris

    hi,
    >>are they generated automatically? at which time? whats the trigger for them to appear?
    Or are they inserted manually?
    automatilly
    RZ70 in SAP ABAP
    and from visual admin - SLD bridge
    Regards,
    Michal Krawczyk

  • PI7.0: SLD - Technical System of type "Exchange Infrastructure"

    Hi Guys,
    The adapter engine was empty in the integration directory and as part of it i followed the steps in the sap note - 764176 Error in XI due to inconsistency in the sld. I did the following steps
    1. Switch to "Home" in the "Technical Landscape" view, and select the
    "Exchange Infrastructure" technical system type there. Select all
    domains and XI components for the host and delete these by selecting
    them and pressing 'Remove'.
    2. Restart the J2EE server. After you restart the server, the XI
    components log on to the SLD again and create a new entity of class
    "XI Integration Server".
    3. To register the directory and repository again, you must also log on
    to the two tools.
    I have restarted the j2ee server and looged into the IR and ID but they are not automatically registered in the central sld.
    central sld is on solmanger box.  How to register IR, ID, RWB and central adapter engine under the technical systems of type exchange infrastructure ?
    any help would be really appreciated
    Thanks,
    Raj

    Hi Reddy,
    i faced the same problem few days back...
    check this link
    /people/venugopalarao.immadisetty/blog/2007/03/15/adapter-engine-cannot-be-found-in-integration-directory
    and also cross-check the post installation steps.
    In my case the Business system for XI was created of type web as java... but it should be of type web as abap.
    Sachin

  • SLD- Technical System Browser

    Hi all,
    When i go to the sld of my XI server and there inside technical landscape when i choose the technical system type as 'Exchange Infrastructure' number of application systems are displayed. I find tht there are application systems corressponding to Repository, Directory , RWB , IS and AE.
    When are these entries getting added.  I believe they are gettin created automatically but when. Is it at the time of installation.
    Any kind of suggestion would be helpful

    hi,
    >>>>Is it at the time of installation.
    AFAIK yes,
    so don't need to maintain it manually later on
    Regards,
    michal

  • SLD - Technical System Wizard - Select System: Only None (Standalone J2EE)

    Hi, I want to connect to some RFC-Modules on a SAP/R3 System from my NetWeaver Web DynPro Application. Therefore I have to create JCO-Connections for the Models I created (MODELDATA_DEST and RFC_METADATA_DEST). For this I have to define the System I want these JCO-Connections to connect to in my SLD which I'm trying to do using the "Technical System Wizard". (SLD -> Technical Landscape -> New Technical System -> Web AS Java (because I'm developing a Java Application).
    In the next screen I have to specifiy the location of my Server. I thought, that here, I have to define my SAP/R3 Server to which the JCO-Connections for my two models shall be connected. But the only option I can choose for "Web AS ABAP" (The ABAP System where my RFC-Modules are stored I guess) is "None (Standalone J2EE)".
    Why is that? Or am I missing something? I thought I have to specify the SAP/R3 System containing the RFC-Modules here and not my local NetWeaver Server.
    Thanks for your help
    Thomas

    Hi,
    there seems to be a misunderstanding here. For JCO to work you need to set up the ABAP-System as a technical system in SLD, otherwise the Java-System is not able to determine information like Hostname and Portnumber for the RFC. Of course it's good to set up your WAS-Java in SLD as a technical system as well, but for the JCO the ABAP side is more important as far as I can see.
    To have a clean start I suggest that you set up all involved technical systems in your SLD.
    Regards,
    Jörg

  • SLD - Technical System  general settings not all filled..is this a problem?

    Hi all,
    I don't really have any experience with the configuration of SAP PI, I just do some maintenance and small adjustments from time to time.
    I noticed in the SLD in the Technical System settings of the AS JAVA that the following fields were not filled in the general tab:
    I'm a bit worried since these fields are filled on our test environment, on our production environment they are not...
    Installation Number: *** not yet assigned *** 
    System Number:      *** not yet assigned ***
    I can't just add this info, it seem I have to make remove the existing one and create a new entry.
    Everything seems to be working fine so I'm a bit reluctant to try and chance this if it's not necessary.
    So my question is, could it cause a poblem further on if these fields are not filled?
    If so, can I fill these fields without removed the existing entry and creating a new one?
    Thanks for any feedback provided.
    Cheers,
    Benjamin

    Hi Michal,
    thanks for your reply.
    Would this be done via the SLD Data Supplier Configuration: SLD Data Supplier in the NWA ?
    I don't have access to this in our production environment right now so I can't try.
    If so, I'll try it later with a system admin.
    B

  • SLD Technical System

    When we create a Technical System in the SLD, it will not accept a fully qualified DNS name, the name seems to truncate at the first period.  (i.e sdn.sap.com turns into sdn).
    Does anyone know how to work around this issue other than adding an entry to the host file?
    Thanks,
    Andrew

    Hi Andrew,
    Please read the "Parameter Help" for host name:
    "By default, host names in SLD are written lower case without any network domain."
    So I guess you can't give a full DNS name even if this may lead to confilicts:
    "This implies to use different System Landscape Directories for network domains having name conflicts at this level"
    Regards,
    Michal Krawczyk
    https://www.sdn.sap.com/sdn/weblogs.sdn?blog=/pub/u/34500 [original link is broken] [original link is broken] [original link is broken] [original link is broken] [original link is broken] [original link is broken] [original link is broken] [original link is broken]

  • SLD-Technical system -Web AS Java

    Dear All,
    I am able create techinical system for Web As ABAP. And want to create Web AS Java. Will you please explain me procedure.

    Hi,
    Ideally you should not create any technical system manually. When you go to SLD Administrstion --> profiles --> Data supplier, here you enter your backend server specific data for e.g. host name, instance number etc, and then you restart your SLD.once this is done successfully then your technical system automatically gets available under Technical Syatems. you should follow the same for JAVA system.
    Regards,
    Ameya

  • SLD - Technical System Types: Third-Party vs. Standalone Java

    Hi all,
    can somebody explain what´s the difference between the technical system types
    "Third-Party" and "Standalone Java"
    Please give also one example for a standalon java type.
    Thanks,
    Kris

    Hi Kris,
    1. Third Party: Can be any Tech System. For example you want to send a xml message from a file adapter residing on your PC. You can define your PC as a 3rd party Tech/Business System.
    2. StandAlone Java: WEBAS640 has bot Basis and Java Stacks. If you installed only the standalone java Stack on a server, then you define a standalone java tech system.
    For more info check the XI-3.0 Help documentation.
    Regards
    Prasad

  • Problem with Portal's SLD technical systems setup..

    Hi guys,
    I'm implementing ESS v60.2. and need to setup portal's SLD. When I'm trying to set-up Web AS ABAP system, I can select no Product (in the last step). System response, that the Product has no Components. I understand, that this is probably problem of basis, but...
    Can anyone help, what to do?
    Thanx, Peter

    You should import the CR Content to the SLD to get the list of components. So, you do this by
    Administration > Import(under Content) >  In the Browse choose the path
    <installation Drive >:\usr\sap\J2E\SYS\global\sld\model and choose CR_Content.zip and Press Import CR Content.
    It will take some time like an hr or more to import. Be patient.
    Now, you will see the produts.
    Hope this helps,
    Kumar

  • Technical system not available in Integration tab of Busines System SLD

    Hi ,
      I am  creating a Business System in SLD(on Solution Manager) for XI system but not able to see any technical system from Integration tab of Business system.
       I have already created a technical system in SLD.
    Please suggest  what other settings I need to check.
    Thanks
    Bhaskar

    Hi,
    Clear the cache and try again.
    Go to Environment -
    > Click on Clear SLD data cache.
    If you still din't get then In the SLD goto technical system, in the dropdown box select your Technical system type(web as Java/....) and cleck on display, if it is there then it was created other wise it wasn't created.

  • Technical System - SLD

    Hello,
    I found that under the technical system type process Integration there is an entry of XI Integration Server but whereas in dev and quality there are 6 entries.
    Below Types are not avialable in SLD technical system.
    XI Domain
    XI Integration Directory
    XI Integration Repository
    XI Runtime Management Serve
    XI Adapter Framework
    Kindly suggest

    Hello
    There should be 6 entries for each PI system in the SLD. If you are missing any, then as a first step you should apply note #764176 Manual correction of XI content in SLD.
    Regards
    Mark

  • Two entries for every technical system for XI in SLD

    Hi,
    Last weekend we had a patch upgrade in our Production env for SAP PI system.
    After that we got the Cache error (Cache notification from Integration Directory failedError when accessing the System Landscape Directory) in RWB -- "Cache Connectivity Test -> IR -> ID -> Adapter Engines".
    And
    In SLD->Technical Systems->all (Adapter Engine, Integration Directory, Integration Repository, RWB).
    e.g.:There are two Adapter Engines:
    Adapter Engine on p80.p80xxxxx
    and
    Adapter Engine on p80.p80xxxxx\p80
    Our Basis team contacted SAP for help & SAP has suggested as below.
    "We compared the SLD->Technical Systems for QA (Q80) and PROD (P80), and found that for the production box (P80), each XI component is registered Twice.
    Now as per the note 764176, we have to delete the entries in the SLD -> Technical Systems. And these will be re-created after a restart.
    Could you please let us know whether these have been maintained for any special reason or we can go ahead and delete them."
    If you have any idea if those two should be maintained or not, please suggest how to proceed.
    Thank you & Best regards,
    Farooq.

    Hi Farooq,
       I have faced the same issue and got resolved by 764176.
    you can go ahead and implement the note 764176 which will resolve your issue.
    Regards,
    naveen

Maybe you are looking for

  • Install issue: HP Photosmart 5514 on HP Envy 20 computer with Windows 8

    I am not able to install th HP PhotoSmart 5514 CQ176-80067 wirelessly (printer does not come with cable) on my HP Envy compuer with Windows 8. Two issues here - wireless (tried installing wireless wizard, cannot find) and software compatiblity with O

  • The simplest way to do dynamic text

    HI! What would be the best way doing dynamic text and objects to your FC builded web site? I know that FC is not developer tool and I probably have to use Flash Builder. I've had lot of request to make web pages with parts that customers can upgrade

  • Upgraded Adobe Flash Player for Mac not working for Youtube

    There was a similar question already asked today. I also tried to watch a video on Youtube from a Mac (OS X 10.5.8) and Safari (ver. 4.0.2). However, instead of the video a recommendation to "Go Upgrade!" comes up on Youtube with the following link:

  • XMP "Copyright status" not accessible?

    Just noticed that for files processed by LR, the "Copyright Status" xmp field, as shown in CS2 "File Info..." Description section (ACR 3.7), is always showing as "Unknown" (the 2 other choices are "Copyrighted" and "Public Domain") This happens for a

  • How can I get into the Dutch App store?

    I am a Dutch Native living in the U.S. and since a few weeks the proud owner of an Ipad 2. I would like to download some Dutch apps for me and my son but I do not know how to get into the Dutch App store or how to find Dutch apps in the U.S. app stor