SNMP Configuration question

I have a question.If i have a SNMP configuration in a switch 4510r, is there any posibility to reach the snmp server without the community command and without the server snmp command??????I have only this lines on the configuration.THANKSSS.
snmp-server engineID local 8000000903000025841E8C38
snmp-server trap-source Vlan10
snmp-server source-interface informs Vlan10
snmp-server packetsize 1024
snmp-server enable traps snmp authentication linkdown linkup coldstart warmstart
snmp-server enable traps config-copy
snmp-server enable traps config
snmp-server enable traps config-ctid
snmp-server enable traps syslog

If i have configured the communities and the server lines on the device, what could be the possible issue when the SNMP server reach the switch but the switch doesn´t respond to the request, and when i use the command #show snmp, we have an output in this way:THANKS FOR YOUR HELP
switch#show snmp
Chassis:
Contact: GISN Americas Network - tel: 978-858-7000
0 SNMP packets input
    0 Bad SNMP version errors
    0 Unknown community name
    0 Illegal operation for community name supplied
    0 Encoding errors
    0 Number of requested variables
    0 Number of altered variables
    0 Get-request PDUs
    0 Get-next PDUs
    0 Set-request PDUs
    0 Input queue packet drops (Maximum queue size 1000)
145568 SNMP packets output
    0 Too big errors (Maximum packet size 1024)
    0 No such name errors
    0 Bad values errors
    0 General errors
    0 Response PDUs
    145568 Trap PDUs
SNMP global trap: enabled
SNMP agent enabled
SNMP logging: enabled
    Logging to 131.98.27.6.162, 0/10, 34282 sent, 0 dropped.
    Logging to 192.97.141.173.162, 0/10, 1721 sent, 0 dropped.
    Logging to 192.97.141.176.162, 0/10, 1721 sent, 0 dropped.
    Logging to 192.97.141.55.162, 0/10, 1721 sent, 0 dropped.

Similar Messages

  • SAP-JEE, SAP_BUILDT, and SAP_JTECHS and Dev Configuration questions

    Hi experts,
    I am configuring NWDI for our environment and have a few questions that I'm trying to get my arms around.  
    I've read we need to check-in SAP-JEE, SAP_BUILDT, and SAP_JTECHS as required components, but I'm confused on the whole check-in vs. import thing.
    I placed the 3 files in the correct OS directory and checked them in via the check-in tab on CMS.   Next, the files show up in the import queue for the DEV tab.  My questions are what do I do next?
    1.  Do I import them into DEV?  If so, what is this actually doing?  Is it importing into the actual runtime system (i.e. DEV checkbox and parameters as defined in the landscape configurator for this track)? Or is just importing the file into the DEV buildspace of NWDI system?
    2.  Same question goes for the Consolidation tab.    Do I import them in here as well? 
    3.  Do I need to import them into the QA and Prod systems too?  Or do I remove them from the queue?
    Development Configuration questions ***
    4. When I download the development configuration, I can select DEV or CON workspace.  What is the difference?  Does DEV point to the sandbox (or central development) runtime system and CONS points to the configuration runtime system as defined in the landscape configurator?  Or is this the DEV an CON workspace/buildspace of the NWDI sytem.
    5.  Does the selection here dictate the starting point for the development?  What is an example scenarios when I would choose DEV vs. CON?
    6.  I have heard about the concept of a maintenance track and a development track.  What is the difference and how do they differ from a setup perspective?   When would a Developer pick one over the over? 
    Thanks for any advice
    -Dave

    Hi David,
    "Check-In" makes SCA known to CMS, "import" will import the content of the SCAs into CBS/DTR.
    1. Yes. For these three SCAs specifically (they only contain buildarchives, no sources, no deployarchives) the build archives are imported into the dev buildspace on CBS. If the SCAs contain deployarchives and you have a runtime system configured for the dev system then those deployarchives should get deployed onto the runtime system.
    2. Have you seen /people/marion.schlotte/blog/2006/03/30/best-practices-for-nwdi-track-design-for-ongoing-development ? Sooner or later you will want to.
    3. Should be answered indirectly.
    4. Dev/Cons correspond to the Dev/Consolidation system in CMS. For each developed SC you have 2 systems with 2 workspaces in DTR for each (inactive/active)
    5. You should use dev. I would only use cons for corrections if they can't be done in dev and transported. Note that you will get conflicts in DTR if you do parallel changes in dev and cons.
    6. See link in No.2 ?
    Regards,
    Marc

  • Snmp configuration on weblogic 10 has no effect

    SNMP in MMC(Mobile Management Center, A HP Product), use joesnmp.jar internal to send snmp trap generated by mmc app. This part works well in weblogic 10;
    snmp in weblogic , configured by weblogic console. In weblogic 8, we configure such items:
    Weblogic Subsystem
    Purpose
    Level
    Deployer
    Monitor all war/ear deploy/undeploy/redeploy
    INFO
    JDBC
    Monitor all warnings/errors in jdbc operation
    WARN
    Current tests shows that the snmp configuration on weblogic 10 has no effect.
    Due to MMC4.6 gets the Weblogic updated from 8.16 to 10.3, we didn’t find the configuration about “Enable JDBC Logging”. Below is the former config page about Weblogic 8.16.
    But in Weblogic 10.3 we cannot find this configuration. We have followed the guide http://e-docs.bea.com/wls/docs100/jdbc_admin/monitor.html#wp1048793
    And tried to set the appropriate properties on the command line like this,
    -Dweblogic.debug.DebugJDBCSQL=true -Dweblogic.log.StdoutSeverity="Info"
    Actually we can get the DM, Core, SMTP, Bulk, Adaptor Class, and connection fail error messages in weblogic backend log, but seems Weblogic cannot send SNMP trap messages to SNMP monitoring tool like Openview.
    PS. Weblogic can send out the SNMP trap messages when the server starts and stops.
    So till now the SNMP cannot monitor the DM, Core, SMTP, Bulk, Adaptor Class, and connection fail for MMC4.6.

    Hi, I am on 12.1 weblogic, and I am stuck on where you set the SNMP Servername and port number.
    We are on windows 2008, I see there is a services, SNMP .
    Is there something I need to do on the weblogic side before i get into the SNMP agenets and traps, this part I understand, I am just unsure where to add the SNMP Servername and the user I wish the emails to go to.
    I see in the security realms the user i can add to the group monitors.
    -->, I am running WL 10.3 and SNMP works fine. The cluster generates traps based on particular mbeans, such as when a server's health state is not "OK", or when there are JDBC connection issues. You have to create a new SNMP agent within the admin server then build the individual traps ( String, Gauge, Counter, etc. ) and make sure you have a Trap Destination.

  • SNMP configuration of Aironet1200 (ios based)

    Hi,
    Could somebody explain where I am going wrong with my SNMP configuration of my Aironet 1200AP.
    I am trying to set up a new SSID, with a WEP key, some radius server info and the ability to toggle requireEAP and requireMAC on and off.
    The sequence of commands I have been trying is given below, this is from the factory default config. After I blast the AP with this config, I get the following problems:
    1. I cannot manipulate the SSID in the web interface any longer
    2. The radius server info never shows up in the web interface
    3. If I try to set RequireMac and/or RequireEAP, the set request goes through, but a get on OIDs shows them as false again.
    4. I cannot associate at all with the device.
    Any thoughts/help would be greatly appreciated.
    Thanks
    Ashleyb
    snmpset -v1 -mall -cpublic 10.8.200.112 \
    CISCO-DOT11-IF-MIB::cd11IfAuxSsidBroadcastSsid.1.1 = 1
    snmpset -v1 -mall -cpublic 10.8.200.112 \
    CISCO-DOT11-IF-MIB::cd11IfAuxSsid.1.1 = "MyNewSid"
    snmpset -v1 -mall -cpublic 10.8.200.112 \
    CISCO-WLAN-VLAN-MIB::cwvlWlanEncryptionMode.0 = 2
    snmpset -v1 -mall -cpublic 10.8.200.112 \
    CISCO-WLAN-VLAN-MIB::cwvlWlanEncryptionMandatory.0 = 1
    snmpset -v1 -mall -cpublic 10.8.200.112 \
    CISCO-DOT11-IF-MIB::cd11IfAuxSsidAuthAlgRequireMac.1.1.1 = 1
    snmpset -v1 -mall -cpublic 10.8.200.112 \
    CISCO-DOT11-IF-MIB::cd11IfAuxSsidAuthAlgRequireEap.1.1.1 = 1
    snmpset -v1 -mall -cpublic 10.8.200.112 \
    RFC1213-MIB::ifAdminStatus.1 = 1
    snmpset -v1 -mall -cpublic 10.8.200.112 \
    CISCO-AAA-SERVER-MIB::casConfigRowStatus.radius.1 = 4
    snmpset -v1 -mall -cpublic 10.8.200.112 \
    CISCO-AAA-SERVER-MIB::casAddress.radius.1 = 10.8.200.109
    snmpset -v1 -mall -cpublic 10.8.200.112 \
    CISCO-AAA-SERVER-MIB::casAuthenPort.radius.1 = 1812
    snmpset -v1 -mall -cpublic 10.8.200.112 \
    CISCO-AAA-SERVER-MIB::casKey.radius.1 = "secret"
    snmpset -v1 -mall -cpublic 10.8.200.112 \
    CISCO-DOT11-IF-MIB::cd11IfVlanEncryptKeyStatus.1.0.1 = 6
    snmpset -v1 -mall -cpublic 10.8.200.112 \
    CISCO-DOT11-IF-MIB::cd11IfVlanEncryptKeyLen.1.0.1 = 13 \
    CISCO-DOT11-IF-MIB::cd11IfVlanEncryptKeyValue.1.0.1 =
    "zzzzzzzzzzzzz" \
    CISCO-DOT11-IF-MIB::cd11IfVlanEncryptKeyTransmit.1.0.1 = 1 \
    CISCO-DOT11-IF-MIB::cd11IfVlanEncryptKeyStatus.1.0.1 = 4

    Getting the SNMP trap community string is not trivial.  The reason for this is that anything which shows the configuration will have this field starred out. You can get to the value, but not in a report-like fashion.  You can, however, search the archived configs under RME > Config Mgmt > Archive Mgmt > Search Archive.  Assuming you know the SNMP trap receiver IP, you could search on:
    snmp-server host x.x.x.x old-string
    That would show you all devices that still had the old community string.
    If you need to force RME to get the new config data, you can simply schedule a Sync Archive job under RME > Config Mgmt > Archive Mgmt > Sync Archive.  Of course, if you made the changes outside of LMS, you will need to manually update DCR with the new community string.

  • SNMP Configuration on solaris10

    Please can anybody put some light on SNMP configuration on Solaris 10.I am newbie on this.I read SMA Agaent on solaris 10 is NET-SNMP compliant.I need to monitor disk usage,CPU load ..So I configured snmpd.conf (inside /etc/sma/snmp) for this.The traps I am getting are of series 1.3.6.1.4.1.8072.3.2.3.But I am not able to figure the MIB s which contains the description of these kind of traps.
    Please help me.

    Hi, I am on 12.1 weblogic, and I am stuck on where you set the SNMP Servername and port number.
    We are on windows 2008, I see there is a services, SNMP .
    Is there something I need to do on the weblogic side before i get into the SNMP agenets and traps, this part I understand, I am just unsure where to add the SNMP Servername and the user I wish the emails to go to.
    I see in the security realms the user i can add to the group monitors.
    -->, I am running WL 10.3 and SNMP works fine. The cluster generates traps based on particular mbeans, such as when a server's health state is not "OK", or when there are JDBC connection issues. You have to create a new SNMP agent within the admin server then build the individual traps ( String, Gauge, Counter, etc. ) and make sure you have a Trap Destination.

  • SNMP configuration in WLC

    hi all,
    Can any one tell me if there is document available for SNMP configuration for WLC 4404?

    http://www.cisco.com/en/US/docs/wireless/controller/7.0MR1/configuration/guide/cg_controller_setting.html#wpmkr1372608
    Configuring the device via snmp is very difficult and there really isn't a document covering that.  WCS uses snmp to configure the controllers.

  • Configuration question on css11506

    Hi
    One of our vip with 4 local servers, currently has https. the http is redirected to https.
    Now, my client has problem which a seriel directories need use http, not https. some thing like. quistion:
         1. If there is any possible, I can configure the vip to filter the special directories and let them to use http not https. and rest pages and directories redirect to https?
         2. If not, I can make another vip to use same local servers, but, is possible to only limited to special directories? and with wild code? some like the directories are partially wild coded, something like, http://web.domain/casedir*/casenumber?
         3. if not on both option, is any way I can fix this problem?
    Any comments will be appreciated
    Thanks in advance
    Julie

    I run my Tangosol cluster with 12 nodes on 3
    machines(each machine with 4 cache server nodes). I
    have 2 important configuration questions. Appreciate
    if you can answer them ASAP.
    - My requirement is that I need only 10000 objects to
    be in cluster so that the resources can be freed upon
    when other caches are loaded. I configured the
    <high-units> to be 10000 but I am not sure if this is
    per node or for the whole cluster. I see that the
    total number of objects in the cluster goes till
    15800 objects even when I configured for the 10K as
    high-units (there is some free memory on servers in
    this case). Can you please explain this?
    It is per backing map, which is practically per node in case of distributed caches.
    - Is there an easy way to know the memory stats of
    the cluster? The memory command on the cluster
    doesn't seem to be giving me the correct stats. Is
    there any other utility that I can use?
    Yes, you can get this and quite a number of other information via JMX. Please check this wiki page for more information.
    I started all the nodes with the same configuration
    as below. Can you please answer the above questions
    ASAP?
    <distributed-scheme>
    <scheme-name>TestScheme</scheme-name>
    <service-name>DistributedCache</service-name>
    <backing-map-scheme>
    <local-scheme>
    <high-units>10000</high-units>
    <eviction-policy>LRU</eviction-policy>
    <expiry-delay>1d</expiry-delay>
    <flush-delay>1h</flush-delay>
    </local-scheme>
    </backing-map-scheme>
    </distributed-scheme>
    Thanks
    RaviBest regards,
    Robert

  • Configuration Question on  local-scheme and high-units

    I run my Tangosol cluster with 12 nodes on 3 machines(each machine with 4 cache server nodes). I have 2 important configuration questions. Appreciate if you can answer them ASAP.
    - My requirement is that I need only 10000 objects to be in cluster so that the resources can be freed upon when other caches are loaded. I configured the <high-units> to be 10000 but I am not sure if this is per node or for the whole cluster. I see that the total number of objects in the cluster goes till 15800 objects even when I configured for the 10K as high-units (there is some free memory on servers in this case). Can you please explain this?
    - Is there an easy way to know the memory stats of the cluster? The memory command on the cluster doesn't seem to be giving me the correct stats. Is there any other utility that I can use?
    I started all the nodes with the same configuration as below. Can you please answer the above questions ASAP?
    <distributed-scheme>
    <scheme-name>TestScheme</scheme-name>
    <service-name>DistributedCache</service-name>
    <backing-map-scheme>
    <local-scheme>
    <high-units>10000</high-units>
    <eviction-policy>LRU</eviction-policy>
    <expiry-delay>1d</expiry-delay>
    <flush-delay>1h</flush-delay>
    </local-scheme>
    </backing-map-scheme>
    </distributed-scheme>
    Thanks
    Ravi

    I run my Tangosol cluster with 12 nodes on 3
    machines(each machine with 4 cache server nodes). I
    have 2 important configuration questions. Appreciate
    if you can answer them ASAP.
    - My requirement is that I need only 10000 objects to
    be in cluster so that the resources can be freed upon
    when other caches are loaded. I configured the
    <high-units> to be 10000 but I am not sure if this is
    per node or for the whole cluster. I see that the
    total number of objects in the cluster goes till
    15800 objects even when I configured for the 10K as
    high-units (there is some free memory on servers in
    this case). Can you please explain this?
    It is per backing map, which is practically per node in case of distributed caches.
    - Is there an easy way to know the memory stats of
    the cluster? The memory command on the cluster
    doesn't seem to be giving me the correct stats. Is
    there any other utility that I can use?
    Yes, you can get this and quite a number of other information via JMX. Please check this wiki page for more information.
    I started all the nodes with the same configuration
    as below. Can you please answer the above questions
    ASAP?
    <distributed-scheme>
    <scheme-name>TestScheme</scheme-name>
    <service-name>DistributedCache</service-name>
    <backing-map-scheme>
    <local-scheme>
    <high-units>10000</high-units>
    <eviction-policy>LRU</eviction-policy>
    <expiry-delay>1d</expiry-delay>
    <flush-delay>1h</flush-delay>
    </local-scheme>
    </backing-map-scheme>
    </distributed-scheme>
    Thanks
    RaviBest regards,
    Robert

  • Is it possible to obtain a report from Ciscoworks LMS3.1 to detail the SNMP configuration of all devices?

    I am about to update/standardize to secure the SNMP configuration for all devices in the network utilizing Ciscoworks.
    There is likely to be variations amongst the devices. Therefore, I would like to generate one report for all the devices, capturing the SNMP configurations, is this possible?
    I know how to complete the work afterwards but am struggling to produce a meaningful report that I can use to build my tasks from.
    I am trying to achieve this using a particular 'role based' account via ACS, so it is possible that I don't have the permissions with this account at present which maybe why I'm not able to do it.
    Thanks!

    Getting the SNMP trap community string is not trivial.  The reason for this is that anything which shows the configuration will have this field starred out. You can get to the value, but not in a report-like fashion.  You can, however, search the archived configs under RME > Config Mgmt > Archive Mgmt > Search Archive.  Assuming you know the SNMP trap receiver IP, you could search on:
    snmp-server host x.x.x.x old-string
    That would show you all devices that still had the old community string.
    If you need to force RME to get the new config data, you can simply schedule a Sync Archive job under RME > Config Mgmt > Archive Mgmt > Sync Archive.  Of course, if you made the changes outside of LMS, you will need to manually update DCR with the new community string.

  • SNMP Configure OnCommand System Manager 3.1 on FAS2020 Ontap 7.3.7

    Hi, I have the to discover snmp after configure SNMP. Even I tried both trap hosts with my windows IP where I installed Oncommand system manager and the IP of Ontap 7.3.7. Can someone please verify which host is correct one? what is the requirement for SNMP configure. Thanks,Kevin.

    Sorry, access for this KB is restricted. Then, check following point and fix them. 1. Check if SNMP agent is enabled.
       filer> options snmp.enable
       If not, enable it by "options snmp.enable on"
    2. Check if SNMP access is allowed.
       filer> options snmp.access
       If IP address of System Manager host is not listed, set it by "options snmp.access host=<IP address>"
    3. Check filer's SNMP community name.
       filer> snmp community
       By default, "ro public" is displayed.
       If you have modified SNMP community name, you need to modify registration on System Manager.
       Edit C:\Users\<username>\NetApp\SystemManager\SystemManager.config and adjust snmp-community
       element under storage-system element.

  • Closed loop configuration question

    I have a motor(with encoder feedback) attached to a linear actuator(with end limit switches).
    The motor has a commercially bought servo drive for control. 
    The servo drive will accept either a step/direction (2 seperate TTL
    digital pulse train inputs) or an analog -10 to 10vdc input for
    control. 
    The purpose is to drive a linear actuator(continiously in and out) in
    closed loop operation utilizing a ( (SV) Setpoint variable)value from a
    file converted to a frequency to compare with an actual ( (PV) Position
    variable) measured frequency.
    I have created and experimented with individual vi's allows analog
    control and digital pulse train control (thankfully with the help of
    examples). 
    Before I pose my question, I would like to make the following
    observations:  It is my understanding that Closed loop control
    means that I dont need to know an exact position at which to drive, but
    constant comparision of PV and SV through PID applictation. 
    Without getting into any proprietery information I can say that the
    constant positioning of the linear actuator will produce a latency of 2
    to 3 seconds based on the time the actuator moves to a new position and
    when the PV will change.  While experimenting with the analog
    input, i noticed imediate response to motor velocity, but after the
    motor is stopped, position is not held in place.  However, while
    experimenting with the Digital pulse train input, I noticed that the
    servo drive can only accept one command at one time; if, halfway
    through a move, position error produces a response to move the linear
    actuator in the opposite or different direction, the origional move
    must finish first. 
    Can anyone recommend the proper configuration for the closed loop control i have described?
    If I can make the system work with the servo drive/motor I plan to use
    the simple (pci 6014) daq card with the Analog out, or utilize the
    digital out.
    If I cant get this to work, we do have a pxi with 7344 motion card(I
    would like to exhaust all efforts to use the PCI 6014 card).
    Depending on where I go from here, I planned to use the PID vi's for the loop control.
    Thanks,
    Wayne Hilburn

    Thanks for the reply
    Jochen.  I realize there is a built-in latency with windows but I
    think the I/O control would be ok.  A change in actuator position
    will not result in an immediate change in process variable;  Is
    there a way to measure the latency or is it calculated?  A
    satisfactory reaction time could be from 1 to 1.5 sec.
    Use of the PCI-6014 is to supply the control output to the servo
    drive/amp, and not to drive the motor itself.  As stated earlier,
    while using the 6014 board, I have the choice of digital or analog
    output.
    Currently I am at a point where I must choose which configuration,
    analog control or digital control(in the form of digital pulse train),
    (i am inserting from first message)
    While experimenting with the analog
    input, i noticed imediate response to motor velocity, but after the
    motor is stopped, position is not held in place.  However, while
    experimenting with the Digital pulse train input, I noticed that the
    servo drive can only accept one command at one time; if, halfway
    through a move, position error produces a response to move the linear
    actuator in the opposite or different direction, the origional move
    must finish first.  .
    I dont claim to understand all the limitations with the
    specific boards, however, i am using an approach that is showing me the
    characteristics(a couple are listed in the above paragraph)  of
    the hardware and software configurations.
    So I am really back to my origional question;  Which configuration
    would be better for closed loop control, analog or digital pulse train?
    Thanks,
    Wayne Hilburn

  • Multiple Oracle Configuration Question

    We have a typical environment setup. I will explain it below:
    Our application works in Online and Offline Mode. For Online mode we connect to Oracle 10g enterprise server and a Local instance of Access and In offline application totally works in Access.
    Now we want to move away from Access and have Oracle PE instead just because we want to use stored procedure and same set of code for offline and online processing.
    So a typical user machine will have a PE instance and a Oracle Client. Currently we use LDAP.ora for Configuring connections. Now i have few questions
    1. How do we ensure that Oracle PE will work when we don't have network connection. Can we have like PE setup with Tnsnames.ORA
    2. What can be the smallest possible package for PE.
    3. Can I use one client to access both PE and Server databases.
    Any help will be highly appreciated.
    Thanks in advance.

    Assuming the "Xcopy installation" refers to using the Windows xcopy command, can you clarify what, exactly, you are installing via xcopy? Are you just using xcopy to copy the ODP.Net bits? Or are you trying to install the Oracle client via that approach?
    If you are concerned about support, you would generally want to install everything via the Oracle Universal Installer (barring those very occasional components that don't use the OUI). Oracle generally only supports software installed via the installer because particularly on Windows, there are a number of registry entries that need to get created.
    You can certainly do a custom install of the personal edition on the end user machines. There are a few required components that I believe have to be installed (that the installer will take care of). I assume your customization will take the form of a response file to the OUI in order to do a silent install?
    Justin

  • CCMS configuration question - more than one sapccmsr agent on one server

    Hello all,
    this might be a newbie question, please excuse:
    We have several SAP systems installed on AIX in several LPARs. SAP aplication server and SAP database is always located in different LPARs, but one LPAR can share application server of several SAP systems or databases of several SAP systems.
    So I want to configure SAPOSCOL and CCMS-Agents (sapccmsr) on our databse LPARS. SAPOSCOL is running - no problem so far. Due to the circumstance that we have DBs for SAP systems with kernel 4.6d, 6.40 (nw2004), 7.00 (nw2004s) I want to use two different CCMS-Agents (Version 6.40 non-unicode to connect to SAP 4.6d and 6.40 + Version 7.00 unicode to connect to SAP 7.00).
    AFAIK only one of these can use shared memory segment #99 (default) - the other one has to be configured to use another one (e.g. #98) but I don't know how (could'nt find any hints on OSS + Online Help + CCMs-Agent manual).
    Any help would be appreciated
    regards
    Christian
    Edited by: Christian Mika on Mar 6, 2008 11:30 AM

    Hello,
    has really no one ever had this kind of problem? Do you all use either one (e.g. windows) server for one application (e.g. SAP application or database) or the same server for application and database? Or don't you use virtual hostnames (aliases) for your servers, so that in all mentioned cases one CCMS-Agent on one server would fit your requirements? I could hardly believe that!
    kind regards
    Christian

  • Master iPad configurator question concerning cart syncing with different versions of iPads.

    I have a question concerning configurator syncing.Can the master iPad be a different version of iPad than the other synced iPads? For instance can iPad 2 be the master iPad to a group of iPad Air's? The iPad 2 has some fewer capabilities than the Air, would some settings or restrictions be left off of the iPad Airs if they were set up this way?  Thanks.

    There is no such thing as 'master iPad'.  If you're using Configurator or Profile Manager control of the setup is done from a Macintosh.

  • Setup/ Configuration Question

    The network setup I'm using is a wireless G router, Belkin brand, and I have four WRE54G expanders throughout the warehouse. I don't have WEP turned on so I used the auto configuration on all of them. They all made connection and they all work. However, each one of them tends to lose connection from time to time. At least once every couple of weeks I have to reset one of them. When they stop working the red light comes on and I know the link is gone. I'll reset it and everything will be fine for a while. I thought I'd try to get into the web utility to check if any settings are off, however because it has been auto configured I'm not sure what the ip address is. It's not the default. We use a 10.x.x.x range and I've scanned the entire range and none of them show up on an IP. The only thing that does, besides the computers connecting, is the router. I've run the linksys setup utility and had it do a site survey but it keeps coming back saying that the site survey failed. I hate to take them all down from where they are mounted and physically connect them to check things, but I'm not sure it that's the problem. Any ideas would be appreciated. Thanks. If the question I am asking here has already been addressed, please point me to the related thread.
    (Edited subject to keep page from stretching. Thanks!)
    Message Edited by JOHNDOE_06 on 06-21-2007 08:57 AM

    Still kinda funny that the site survey fails. Are you using a Vista computer? Saw that using a XP computer solved someone's problem.
    If you can't get the setup software to work you really need to find out what IPs were assigned to the REs to access the IE interface or hard wire them (v2 and 3). I know it is alot of work. I guess you have to assess how much of a hassle it is.
    I don't know if the RE shows up on ipconfig/all. I guess it should since it has a unique IP address. Mines the default so I'll check and repost.
    I'm wondering what the effect is of having 4 REs in relatively "close" proximity is? When mine loses connection (infrequently), the light turns red but immediately turns blue cuz it connects to router again (got only 1 RE). Would your's connect to the router or to another RE? If it connects to another RE, I guess you lose half the speed again. Interesting....
    Also, other than the blue lights, do have any other indication that the REs are working, e.g. increased signal?
    Message Edited by Luckydog on 06-21-2007 11:53 AM
    Message Edited by Luckydog on 06-21-2007 12:02 PM
    Message Edited by Luckydog on 06-21-2007 12:13 PM

Maybe you are looking for